Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “microscopy analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,351 records · Page 75

Towards scanning nanostructure X-ray microscopy

This article demonstrates spatial mapping of the local and nanoscale structure of thin film objects using spatially resolved pair distribution function (PDF) analysis of synchrotron X-ray diffraction data. This is exemplified in a lab-on-chip combinatorial array of sample spots containing catalytically interesting nanoparticles deposited from liquid precursors using an ink-jet liquid-handling system. A software implementation is presented of the whole protocol, including an approach for automated data acquisition and analysis using the atomic PDF method. The protocol software can handle semi-automated data reduction, normalization and modeling, with user-defined recipes generating a comprehensive collection of metadata and analysis results. By slicing the collection using included functions, it is possible to build images of different contrast features chosen by the user, giving insights into different aspects of the local structure.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

High-Energy X-ray Diffraction Microscopy for Nuclear Forensics (FY23 Project Report)

Morphological information on nuclear material has been identified using visible light and scanning electron microscopy. These identify qualitative differences in particle morphology. Three-dimensional imaging of materials through alternating scanning electron microscopy imaging and focused ion beam milling has also been used. Unfortunately, these techniques are time- and labor-intensive, with significant sample preparation required and lengthy analysis times. Further, the resulting 3D images are qualitative, require manual identification, and do not capture statistically-representative populations. High energy X-ray 3D imaging using a direct-beam or diffracted-beam (High-Energy Diffraction Microscopy) have been developed at the Advanced Photon Source and can produce quantitative information on grains (phase, location, etc.) and pores (size distribution, sphericity) in a material. These techniques require only minutes to characterize a sample volume and are non-destructive, thus suitable for a wide range of existing samples and for confirmatory analyses to be carried out using conventional microscopy techniques.

36 MATERIALS SCIENCE↗

Stereoscopic high-speed microscopy to understand transient internal flow processes in high-pressure nozzles

The flow and cavitation behavior inside fuel injectors is known to affect spray development, mixing and combustion characteristics. We discuss that while diesel fuel injectors with converging and hydro-eroded holes are generally known to limit cavitation and feature higher discharge coefficients during the steady period of injection, less is known about the flow during transient periods corresponding to needle opening and closing. Multiple injection strategies involve short injections, multiplying these aspects and giving them a growing importance as part of the fuel delivery process. In this study, single-hole transparent nozzles were manufactured with the same hole inlet radius and diameter as the Engine Combustion Network Spray D nozzle, mounted to a modified version of a common-rail Spray A injector body and needle. Needle opening and closing periods were visualized with stereoscopic high-speed microscopy at injection pressures relevant to modern diesel engines. Time-resolved sac pressure was extracted via elastic deformation analysis of the transparent nozzles. Sources of cavitation were observed and tracked, enabling the identification of a gas exchange process after the end of injection with ingestion of chamber gas into the sac and orifice. We observed that the gas exchange contributed widely to disrupting the start of injection and outlet flow during the subsequent injection event.

42 ENGINEERING↗

Universally Accessible Structural Data on Macromolecular Conformation, Assembly, and Dynamics by Small Angle X-Ray Scattering for DNA Repair Insights.

Structures provide a critical breakthrough step for biological analyses, and small angle X-ray scattering (SAXS) is a powerful structural technique to study dynamic DNA repair proteins. As toxic and mutagenic repair intermediates need to be prevented from inadvertently harming the cell, DNA repair proteins often chaperone these intermediates through dynamic conformations, coordinated assemblies, and allosteric regulation. By measuring structural conformations in solution for both proteins, DNA, RNA, and their complexes, SAXS provides insight into initial DNA damage recognition, mechanisms for validation of their substrate, and pathway regulation. Here, we describe exemplary SAXS analyses of a DNA damage response protein spanning from what can be derived directly from the data to obtaining super resolution through the use of SAXS selection of atomic models. We outline strategies and tactics for practical SAXS data collection and analysis. Making these structural experiments in reach of any basic and clinical researchers who have protein, SAXS data can readily be collected at government-funded synchrotrons, typically at no cost for academic researchers. In addition to discussing how SAXS complements and enhances cryo-electron microscopy, X-ray crystallography, NMR, and computational modeling, we furthermore discuss taking advantage of recent advances in protein structure prediction in combination with SAXS analysis.

Chinnam, Naga Babu↗

Analysis of defect structure in silicon. Characterization of samples from UCP ingot 5848-13C

Statistically significant quantitative structural imperfection measurements were made on samples from ubiquitous crystalline process (UCP) Ingot 5848 - 13 C. Important trends were noticed between the measured data, cell efficiency, and diffusion length. Grain boundary substructure appears to have an important effect on the conversion efficiency of solar cells from Semix material. Quantitative microscopy measurements give statistically significant information compared to other microanalytical techniques. A surface preparation technique to obtain proper contrast of structural defects suitable for QTM analysis was perfected.

Natesh, R.↗

Analysis of Interpretable Data Representations for 4D-STEM Using Unsupervised Learning

Abstract Understanding the structure of materials is crucial for engineering devices and materials with enhanced performance. Four-dimensional scanning transmission electron microscopy (4D-STEM) is capable of mapping nanometer-scale local crystallographic structure over micron-scale field of views. However, 4D-STEM datasets can contain tens of thousands of images from a wide variety of material structures, making it difficult to automate detection and classification of structures. Traditional automated analysis pipelines for 4D-STEM focus on supervised approaches, which require prior knowledge of the material structure and cannot describe anomalous or deviant structures. In this article, a pipeline for engineering 4D-STEM feature representations for unsupervised clustering using non-negative matrix factorization (NMF) is introduced. Each feature is evaluated using NMF and results are presented for both simulated and experimental data. It is shown that some data representations more reliably identify overlapping grains. Additionally, real space refinement is applied to identify spatially distinct sample regions, allowing for size and shape analysis to be performed. This work lays the foundation for improved analysis of nanoscale structural features in materials that deviate from expected crystallographic arrangement using 4D-STEM.

Bruefach, Alexandra (ORCID:0000000209323477)↗

Phagosomal chloride dynamics in the alveolar macrophage

Acidification in intracellular organelles is tightly linked to the influx of Cl – counteracting proton translocation by the electrogenic V-ATPase. We quantified the dynamics of Cl – transfer accompanying cargo incorporation into single phagosomes in alveolar macrophages (AMs). Phagosomal Cl – concentration and acidification magnitude were followed in real time with maximal acidification achieved at levels of approximately 200 mM. Live cell confocal microscopy verified that phagosomal Cl – influx utilized predominantly the Cl – channel CFTR. Relative levels of elemental chlorine (Cl) in hard X-ray fluorescence microprobe (XFM) analysis within single phagosomes validated the increase in Cl – content. XFM revealed the complex interplay between elemental K content inside the phagosome and changes in Cl – during phagosomal particle uptake. Cl – -dependent changes in phagosomal membrane potential were obtained using second harmonic generation (SHG) microscopy. These studies provide a mechanistic insight for screening studies in drug development targeting pulmonary inflammatory disease.

59 BASIC BIOLOGICAL SCIENCES↗

Single-particle detection of enhanced polarizability in Au-decorated semiconducting nanorods via scanning dielectric microscopy

Hybrid nanostructures that combine semiconducting and metallic components offer great potential for photothermal therapy, optoelectronics, and sensing, by integrating tunable optical properties with enhanced light absorption and charge transport. Boosting the integrated performance of these hybrid systems demands techniques capable of probing local variations of the physical properties inaccessible to bulk analysis. Here, we report the single-particle dielectric characterization of hybrid, semiconducting bismuth sulfide (Bi 2 S 3 ) nanorods (NR) decorated with metallic Au nanoparticles (NP), employing scanning dielectric microscopy, which uses electrostatic force microscopy in combination with finite-element numerical simulations. We reveal a pronounced enhancement in the local dielectric response of Bi2S3 upon Au decoration, attributed to interfacial polarization and electron transfer from Au to the Bi 2 S 3 matrix, thus suggesting a enhanced metallic-like polarizability at the single-particle level. Numerical simulations show that the response is dominated by the vertical component of the permittivity and that the decorating metallic Au NP produce only moderate shielding of the semiconductor Bi 2 S 3 NR core, indicating that the large increase in the dielectric response originates primarily from intrinsic modifications within the NR. Overall, these findings provide direct insight into structure–property relationships at the single-particle level, supporting the rational design of advanced hybrid nanostructures with tailored electronic functionalities.

36 MATERIALS SCIENCE↗

Unraveling the impact of initial choices and in-loop interventions on learning dynamics in autonomous scanning probe microscopy

The current focus in Autonomous Experimentation (AE) is on developing robust workflows to conduct the AE effectively. This entails the need for well-defined approaches to guide the AE process, including strategies for hyperparameter tuning and high-level human interventions within the workflow loop. This paper presents a comprehensive analysis of the influence of initial experimental conditions and in-loop interventions on the learning dynamics of Deep Kernel Learning (DKL) within the realm of AE in scanning probe microscopy. We explore the concept of the “seed effect,” where the initial experiment setup has a substantial impact on the subsequent learning trajectory. Additionally, we introduce an approach of the seed point interventions in AE allowing the operator to influence the exploration process. Using a dataset from Piezoresponse Force Microscopy on PbTiO 3 thin films, we illustrate the impact of the “seed effect” and in-loop seed interventions on the effectiveness of DKL in predicting material properties. The study highlights the importance of initial choices and adaptive interventions in optimizing learning rates and enhancing the efficiency of automated material characterization. This work offers valuable insights into designing more robust and effective AE workflows in microscopy with potential applications across various characterization techniques.

47 OTHER INSTRUMENTATION↗

Scanning Electrochemical Microscopy for Kinetic Investigations in Viscous Deep Eutectic Solvents: Identifying Practical Approach Curves and Deviations from Electron Transfer Models

Determining heterogeneous electrochemical electron transfer (ET) kinetics in electrolytes with a wide range of physical properties is of great interest for achieving high-performance redox flow batteries. Among such electrolytes, concentrated hydrogen-bonded electrolytes (CoHBEs), including deep eutectic solvents (DESs), have recently garnered significant attention. Unfortunately, traditional Tafel analysis using macroelectrodes often encounters issues with mass transfer limitations in CoHBEs with high viscosities, thereby restricting kinetic analysis to a narrow potential window. Here, in this work, we introduce a methodology for evaluating ET kinetics in viscous DES using the scanning electrochemical microscopy (SECM). We first determined practical solutions to SECM tip positioning in ethaline DES, which yield pseudopositive feedback responses. Lattice Boltzmann method (LBM) simulations helped us rationalize the impact of the fluid and concentration fields, as well as tip geometry, tip approach velocity v, and the solvent viscosity ηs, on the shape of the approach curves. In addition to successfully recreating approach curves over a variety of conditions, we found that approaching a conductor ensured a practical point where the normalized tip response (Ni T = 2) converged at L = 0.7 within ∼10% error regardless of tip velocity. With positioning capabilities at hand, we investigated the kinetics of Fe 3+ /Fe 2+ redox couple in aqueous and the ethaline media. The experimental kinetic results were interpreted using the Butler–Volmer (BV) and Marcus–Hush–Chidsey (MHC) models. For ethaline, a nonideal kinetic behavior was observed, potentially attributed to solvent dynamics within DESs or to the interplay of chloride anions in the charge transfer process.

electrodes↗

Enzymatic Biocontrol of Fire Blight ( Erwinia amylovora ) Using an Engineered Glycosyl Hydrolase

Current management of fire blight, caused by Erwinia amylovora , relies heavily on streptomycin a practice that has contributed to the emergence of antibiotic-resistant strains and raised environmental and regulatory concerns. Enzyme-based biocontrol agents offer a promising antibiotic-free approach that combines target specificity with environmental compatibility. This study evaluates CAase, a bacteriophage-derived glycosyl hydrolase, for its ability to disrupt E. amylovora biofilms and reduce disease severity. Biochemical assays and scanning electron microscopy confirmed that CAase efficiently degraded the extracellular polysaccharide (EPS) matrix, releasing cells from biofilms. Gas chromatography–mass spectrometry (GC–MS) linkage analysis of EPS isolated from two Erwinia amylovora strains demonstrated that CAase preferentially cleaves galactan-rich amylovoran produced by strain EA273, while exhibiting only limited activity toward the levan-rich EPS from strain EA1430. Functional assays revealed that CAase reduced bacterial viability by nearly 2 orders of magnitude at higher enzyme concentrations, strongly suppressed surface motility, and induced ultrastructural damage visible by transmission electron microscopy. Importantly, field trials showed that CAase significantly lowered blossom and shoot blight incidence under orchard conditions. These results highlight CAase as a potent enzyme-based strategy for reducing the virulence of E. amylovora and demonstrate its potential as a sustainable alternative to antibiotics in fire blight management.

antibiotic resistance↗

Effect of Lithium Doping on MgO Hydroxylation and Carbonation

Recovery of magnesium from brines can potentially be used to source MgO (periclase) as a CO 2 sorbent or for Mg-based cements. However, it is not clear how common impurities in brines, such as lithium, affect the resulting MgO reactivity. Here, to test the effect of lithium incorporation on MgO reactivity for hydration and carbonation, we combined computational simulations with experiments. Experimentally altered (Mg,Li)O with a low dopant concentration (0.012 ± 0.002% w/w Li) was characterized using synchrotron-based X-ray scattering and high-resolution electron microscopy to measure reaction layer formation on (Mg,Li)O. Single-crystal X-ray diffraction analysis of (Mg,Li)O demonstrates that the incorporation of lithium leads to the formation of oxygen vacancies. The presence of vacancies is likely causing faster hydroxylation rates as predicted by ab initio molecular dynamics simulations. However, the faster hydroxylation rates likely lead to faster passivation of the surface because we observe thinner reaction layers on (Mg,Li)O samples both over short time periods (30 days) and over long time periods (28 years). After 28 years, the reaction layer on the (Mg,Li)O sample was less than one-third of the thickness of that of the pure MgO sample. In addition, over 30 days, reaction layers on (Mg,Li)O samples primarily formed at steps rather than on terraces, in contrast to our previous observations on MgO. Based on our results, naturally occurring impurities in MgO modify its reactivity even at very low concentrations and need to be considered for accurate reaction rate prediction for application of MgO as a CO 2 sorbent or in cements.

MgO↗

Analysis of defect structure in silicon. Characterization of SEMIX material. Silicon sheet growth development for the large area silicon sheet task of the low-cost solar array project

Statistically significant quantitative structural imperfection measurements were made on samples from ubiquitous crystalline process (UCP) Ingot 5848 - 13C. Important correlation was obtained between defect densities, cell efficiency, and diffusion length. Grain boundary substructure displayed a strong influence on the conversion efficiency of solar cells from Semix material. Quantitative microscopy measurements gave statistically significant information compared to other microanalytical techniques. A surface preparation technique to obtain proper contrast of structural defects suitable for quantimet quantitative image analyzer (QTM) analysis was perfected and is used routinely. The relationships between hole mobility and grain boundary density was determined. Mobility was measured using the van der Pauw technique, and grain boundary density was measured using quantitative microscopy technique. Mobility was found to decrease with increasing grain boundary density.

Natesh, R.↗

IMIS: An intelligence microscope imaging system

Until recently microscope users in space relied on traditional microscopy techniques that required manual operation of the microscope and recording of observations in the form of written notes, drawings, or photographs. This method was time consuming and required the return of film and drawings from space for analysis. No real-time data analysis was possible. Advances in digital and video technologies along with recent developments in article intelligence will allow future space microscopists to have a choice of three additional modes of microscopy: remote coaching, remote control, and automation. Remote coaching requires manual operations of the microscope with instructions given by two-way audio/video transmission during critical phases of the experiment. When using the remote mode of microscopy, the Principal Investigator controls the microscope from the ground. The automated mode employs artificial intelligence to control microscope functions and is the only mode that can be operated in the other three modes as well. The purpose of this presentation is to discuss the advantages and disadvantages of the four modes of of microscopy and how the IMIS, a proposed intelligent microscope imaging system, can be used as a model for developing and testing concepts, operating procedures, and equipment design of specifications required to provide a comprehensive microscopy/imaging capability onboard Space Station Freedom.

Caputo, Michael↗

Quantifying the Impact of Charge Rate and Number of Cycles on Structural Degeneration of Li-Ion Battery Electrodes

A quantitative link between crack evolution in lithium-ion positive electrodes and the degrading performance on cells is not yet well established nor is any single technique capable of doing so widely available. Here, we demonstrate a widely accessible high-throughput approach to quantifying crack evolution within electrodes. The approach applies super-resolution scanning electron microscopy (SEM) imaging of cross-sectioned NMC532 electrodes, followed by segmentation and quantification of crack features. Crack properties such as crack intensity, crack width and length are quantified as a function of charge rate (1C, 6C, and 9C) and cycle number (25, 225, and 600 cycles). Hundreds of particles are characterized for statistical confidence in the quantitative crack measurements. The data on crack evolution is compared to electrochemical data from full cells and half cells with the NMC532 positive electrodes. We show that while crack evolution strongly correlates with capacity fade in the first 25 cycles, it does not correlate well for the following hundreds of cycles indicating that cracking may not be the dominant cause of capacity fade throughout the cycle-life of cells.

25 ENERGY STORAGE↗

Intentional Uranium Tagging for Material Provenance and Pathway Forensics (LA19-Intentional-Forensics-NDD3Bb) (Annual Report for FY21)

This report describes the outcomes of the third and final year of a project to research the feasibility of tagging uranium materials, especially nuclear fuels. The experimental focus remained on metallic uranium forms under prospective surface and bulk tagging scenarios. Overall, the results showed that the tags could be successfully imparted and characterized in both as-built and degraded conditions. This was in line with expectations coming into this project, indicating promise for both surface and bulk tagging of metallic forms of uranium. Multiple surface tagging techniques and detection strategies were explored in FY21, with an emphasis on improving tag quality, readability, and detection in the field. Non-radioactive materials were used as a testbed. Selective deposition via laser beam was determined to be successful in imparting a readable titanium deposit on a stainless steel base plate, and can be read with high resolution characterization techniques (e.g., scanning electron microscopy) and field capable tools (e.g., eddy current testing). Other deposition techniques, such as selective deposition via electron beam and photoluminescent tags, were explored in FY21, and while success for these techniques would be dependent on additional work, these techniques showed potential for surface tagging applications. To survey bulk taggant elements for bulk uranium metal, 16 tagging elements were spread among 18 depleted uranium castings (4 baseline, 3 mix, 1 dilution, and 10 recycle). Most of these were made and characterized in FY21. Taggant acceptability was based upon manufacturability, detectability, and persistence from the standpoint of two detection options: bulk chemical analysis (for “chemical taggants”) and microstructural analysis (for “second phase taggants”). Taggant detection in both up-front manufacturing and in the face of “degradations” such as dilution, mixing, and recycling was generally good. Two independent laboratories carried out chemical analysis on most of the castings, and often at several locations within a casting, and the results are discussed. Scanning electron microscopy+EDS microanalysis revealed the second phases mostly contained the expected tagging elements. The shapes and 2 spatial distributions of these micron-sized carbides, oxides, and intermetallic particles offers opportunities for further science-based investigation and tagging optimization. Overall, V and Co currently appear as the best choices for chemical taggants while Al, Ti, Mn, Co, Pd, and Tb all look good as second phase taggants. The other elements considered here – Sc, Ni, Ge, Nb, Ce, Ta, W, Ir, and Au – while not being ruled out, require more study to become viable options. It is of special note that in the recycling study only one of the 12 elements fell out of detection even after 10 meltings, demonstrating their persistence. An Appendix tabulates all chemical analysis results to enable more quantitative and statistical studies of detection opportunities and limitations, as a part of a related project.

36 MATERIALS SCIENCE↗

Analysis of neptunium oxides produced through modified direct denitration

Production of neptunium-237 ( 237 Np) target materials for plutonium-238 ( 238 Pu) radioisotope thermoelectric generators (RTGs) for deep space exploration requires advanced chemistry and engineering development. Currently, the domestic Pu-238 Supply Program at Oak Ridge National Laboratory produces neptunium dioxide (NpO 2 ) for target material using a modified direct denitration (MDD) flowsheet. Although the chemistry, reaction mechanisms, and product characteristics of MDD are well understood for uranium, corresponding studies of the neptunium system are still needed to continue optimization of target material properties, production equipment design, and production flowsheets. Here, the objective of this work is to characterize crystalline phases, morphology, surface texture, and particle size of NpO 2 produced via MDD reactions. Solid-phase characterization techniques, including powder X-ray diffraction (pXRD) and scanning electron microscopy with energy-dispersive spectroscopy (SEM-EDS), were employed to achieve this objective. Subsequent data processing using the Morphological Analysis for Material Attribution (MAMA) software was performed to analyze particle morphology and size. Broadly, the powders were found to contain a mixture of NpO 2 and Np 2 O 5 after denitration with a variety of morphologies. After high-firing, the product was found to be NpO 2 with a typical polycrystalline oxide morphology and a grain size ranging from 0.72 to 0.94 µm. These analyses provide knowledge on the reaction pathway for a non-traditional NpO 2 synthesis method and offer additional unique insight into production-scale environments for transuranic materials.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Multiscale X-ray phase contrast imaging of human cartilage for investigating osteoarthritis formation

The evolution of cartilage degeneration is still not fully understood, partly due to its thinness, low radio-opacity and therefore lack of adequately resolving imaging techniques. X-ray phase-contrast imaging (X-PCI) offers increased sensitivity with respect to standard radiography and CT allowing an enhanced visibility of adjoining, low density structures with an almost histological image resolution. This study examined the feasibility of X-PCI for high-resolution (sub-) micrometer analysis of different stages in tissue degeneration of human cartilage samples and compare it to histology and transmission electron microscopy. Ten 10%-formalin preserved healthy and moderately degenerated osteochondral samples, post-mortem extracted from human knee joints, were examined using four different X-PCI tomographic set-ups using synchrotron radiation the European Synchrotron Radiation Facility (France) and the Swiss Light Source (Switzerland). Volumetric datasets were acquired with voxel sizes between 0.7 × 0.7 × 0.7 and 0.1 × 0.1 × 0.1 µm 3 . Data were reconstructed by a filtered back-projection algorithm, post-processed by ImageJ, the WEKA machine learning pixel classification tool and VGStudio max. For correlation, osteochondral samples were processed for histology and transmission electron microscopy. X-PCI provides a three-dimensional visualization of healthy and moderately degenerated cartilage samples down to a (sub-)cellular level with good correlation to histologic and transmission electron microscopy images. X-PCI is able to resolve the three layers and the architectural organization of cartilage including changes in chondrocyte cell morphology, chondrocyte subgroup distribution and (re-)organization as well as its subtle matrix structures. X-PCI captures comprehensive cartilage tissue transformation in its environment and might serve as a tissue-preserving, staining-free and volumetric virtual histology tool for examining and chronicling cartilage behavior in basic research/laboratory experiments of cartilage disease evolution.

3D analysis↗