Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “measurement errors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,351 records · Page 75

Analysis of strapdown sensor testing

Some topics related to dynamic testing of strapdown sensors are analyzed, with emphasis on measuring parameters which give rise to motion-induced error torques in single-degree-of-freedom inertial sensors. The objective is to determine the dynamic inputs, test equipment characteristics and data processing procedures best suited for measuring these parameters. Single axis, low frequency vibration tests and constant rate tests are studied in detail. Methods for analyzing the effects of test motion errors and measurement errors are developed and illustrated by examples. Candidate test data processing methods are compared and recommendations concerning test equipment and data processing are made.

Crawford, B. S.↗

Monte Carlo neutronics benchmarks on nuclear fuel depletion: A review

Monte Carlo (MC) neutronics codes are used widely for academic and industrial needs. Several schemes of coupling MC neutronics code with isotope generation and depletion code exist, which are used for performing nuclear fuel depletion simulations. These simulations can estimate the inventory of isotopes in neutron irradiated nuclear reactor fuel. However, the accuracy of these simulations shall be validated through experiments. MC codes are seldom validated by isotopic benchmarks compared to criticality benchmarks. This work compiles and analyzes the fuel depletion benchmarks and validations used to analyze the performance of MC-based fuel depletion neutronics codes. Analyses of these benchmarks and validations showed that the computed concentrations of 133 Cs, 135 Cs, 137 Cs, 148 Nd, 239 Pu, 240 Pu, and 241 Pu in the irradiated fuel by the depletion codes agreed with the measured values within 10% error. However, the computed concentrations of 125 Sb, 242 Cm, 243 Cm, 244 Cm, 245 Cm, and 246 Cm had errors more than 15% compared to the measured values. As a result, Ventina depletion code showed the most accurate predictions for the greatest number of isotope concentrations compared to ORIGEN2 and CINDER90.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Maximum likelihood techniques applied to quasi-elastic light scattering

There is a necessity of having an automatic procedure for reliable estimation of the quality of the measurement of particle size from QELS (Quasi-Elastic Light Scattering). Getting the measurement itself, before any error estimates can be made, is a problem because it is obtained by a very indirect measurement of a signal derived from the motion of particles in the system and requires the solution of an inverse problem. The eigenvalue structure of the transform that generates the signal is such that an arbitrarily small amount of noise can obliterate parts of any practical inversion spectrum. This project uses the Maximum Likelihood Estimation (MLE) as a framework to generate a theory and a functioning set of software to oversee the measurement process and extract the particle size information, while at the same time providing error estimates for those measurements. The theory involved verifying a correct form of the covariance matrix for the noise on the measurement and then estimating particle size parameters using a modified histogram approach.

Edwards, Robert V.↗

A comparison of small and larger mesoscale latent heat and radiative fluxes: December 6 case study

Because of the small amounts of water vapor, the potential for rapid changes, and the very cold temperatures in the upper troposphere, moisture measuring instruments face several problems related to calibration and response. Calculations of eddy moisture fluxes are, therefore, subject to significant uncertainty. The purpose of this study is to examine the importance of latent heat (moisture) fluxes due to small and larger mesoscale circulations in comparison to radiative fluxes within cirrus. Scale separation is made at about 1 km because of significant changes in the structures within cirrus. Only observations at warmer than -40 C are used in this study. The EG&G hygrometer that is used for measuring dewpoint temperature (Td) is believed to be fairly accurate down to -40 C. On the other hand, Lyman-Alpha (L-alpha) hygrometer measurements of moisture may include large drift errors. In order to compensate for these drift errors, the L-alpha hygrometer is often calibrated against the EG&G hygrometer. However, large errors ensue for Td measurements at temperatures less than -40 C. The cryogenic hygrometer frost point measurements may be used to calibrate L-alpha measurements at temperatures less than -40 C. In this study, however, measurements obtained by EG&G hygrometer and L-alpha measurements are used for the flux calculations.

Gultepe, I.↗

Monocrystalline silicon gradiometer for gravity experiments in space

A very important research effort has been made in the last decade in the field of high precision measurement with laser instrumentation. The development of a space borne gradiometer operating at a high sensitivity level using laser measurement of the distance between proof mass over a short base line of order one meter is discussed. Two aspects of laser technology make it a promising tool for gradiometry measurements: quantum limited accuracy and absolute distance measurements. The quantum limit associated with laser instrumentation was formulated. The relevant quantum and classical sources of errors in laser measurements were reviewed and corresponding laser performance requirements for gradient measurements were evaluated. Some mechanical quality factor measurements were made on simple resonant monocrystalline silicon suspensions. It was discovered that the use of zero derivative restoring forces to position the gradiometer test masses will dramatically reduce the gradiometer temperature control requirements. A laser beam side injection scheme was discovered which permits rejection of common mode accelerations. These concepts are briefly discussed.

Richard, Jean-Paul↗

The temperature of the cosmic microwave background radiation at 3.8 GHz - Results of a measurement from the South Pole site

As part of an international collaboration to measure the low-frequency spectrum of the cosmic microwave background (CMB) radiation, its temperature was measured at a frequency of 3.8 GHz, during the austral spring of 1989, obtaining a brightness temperature, T(CMB), of 2.64 +/-0.07 K (68 percent confidence level). The new result is in agreement with previous measurements at the same frequency obtained in 1986-88 from a very different site and has comparable error bars. Combining measurements from all years, T(CMB) = 2.64 +/-0.06 K is obtained.

De Amici, Giovanni↗

Towards the 1 mm/y Stability of the Radial Orbit Error at Regional Scales

An estimated orbit error budget for the Jason-1 and Jason-2 GDR-D solutions is constructed, using several measures of orbit error. The focus is on the long-term stability of the orbit time series for mean sea level applications on a regional scale. We discuss various issues related to the assessment of radial orbit error trends; in particular this study reviews orbit errors dependent on the tracking technique, with an aim to monitoring the long-term stability of all available tracking systems operating on Jason-1 and Jason-2 (GPS, DORIS, SLR). The reference frame accuracy and its effect on Jason orbit is assessed. We also examine the impact of analysis method on the inference of Geographically Correlated Errors as well as the significance of estimated radial orbit error trends versus the time span of the analysis. Thus a long-term error budget of the 10-year Jason-1 and Envisat GDR-D orbit time series is provided for two time scales: interannual and decadal. As the temporal variations of the geopotential remain one of the primary limitations in the Precision Orbit Determination modeling, the overall accuracy of the Jason-1 and Jason-2 GDR-D solutions is evaluated through comparison with external orbits based on different time-variable gravity models. This contribution is limited to an East-West "order-1" pattern at the 2 mm/y level (secular) and 4 mm level (seasonal), over the Jason-2 lifetime. The possibility of achieving sub-mm/y radial orbit stability over interannual and decadal periods at regional scales and the challenge of evaluating such an improvement using in situ independent data is discussed.

Precision Orbit Determination (POD)↗

Radio metric errors due to mismatch and offset between a DSN antenna beam and the beam of a troposphere calibration instrument

Two components of the error of a troposphere calibration measurement were quantified by theoretical calculations. The first component is a beam mismatch error, which occurs when the calibration instrument senses a conical volume different from the cylindrical volume sampled by a Deep Space Network (DSN) antenna. The second component is a beam offset error, which occurs if the calibration instrument is not mounted on the axis of the DSN antenna. These two error sources were calculated for both delay (e.g., VLBI) and delay rate (e.g., Doppler) measurements. The beam mismatch error for both delay and delay rate drops rapidly as the beamwidth of the troposphere calibration instrument (e.g., a water vapor radiometer or an infrared Fourier transform spectrometer) is reduced. At a 10-deg elevation angle, the instantaneous beam mismatch error is 1.0 mm for a 6-deg beamwidth and 0.09 mm for a 0.5-deg beam (these are the full angular widths of a circular beam with uniform gain out to a sharp cutoff). Time averaging for 60-100 sec will reduce these errors by factors of 1.2-2.2. At a 20-deg elevation angle, the lower limit for current Doppler observations, the beam-mismatch delay rate error is an Allan standard deviation over 100 sec of 1.1 x 10(exp -14) with a 4-deg beam and 1.3 x 10(exp -l5) for a 0.5-deg beam. A 50-m beam offset would result in a fairly modest (compared to other expected error sources) delay error (less than or equal to 0.3 mm for 60-sec integrations at any elevation angle is greater than or equal to 6 deg). However, the same offset would cause a large error in delay rate measurements (e.g., an Allan standard deviation of 1.2 x 10(exp -14) over 100 sec at a 20-deg elevation angle), which would dominate over other known error sources if the beamwidth is 2 deg or smaller. An on-axis location is essential for accurate troposphere calibration of delay rate measurements. A half-power beamwidth (for a beam with a tapered gain profile) of 1.2 deg or smaller is desired for calibration of all types of radio metrics. A water-vapor radiometer calibration beam of this size with very low sidelobes would require a clear aperture antenna with a diameter of at least 1.5 m if the primary water vapor sensing channel were in the 20-22 GHz range.

R P Linfield↗

Formaldehyde Distribution over North America: Implications for Satellite Retrievals of Formaldehyde Columns and Isoprene Emission

Formaldehyde (HCHO) columns measured from space provide constraints on emissions of volatile organic compounds (VOCs). Quantitative interpretation requires characterization of errors in HCHO column retrievals and relating these columns to VOC emissions. Retrieval error is mainly in the air mass factor (AMF) which relates fitted backscattered radiances to vertical columns and requires external information on HCHO, aerosols, and clouds. Here we use aircraft data collected over North America and the Atlantic to determine the local relationships between HCHO columns and VOC emissions, calculate AMFs for HCHO retrievals, assess the errors in deriving AMFs with a chemical transport model (GEOS-Chem), and draw conclusions regarding space-based mapping of VOC emissions. We show that isoprene drives observed HCHO column variability over North America; HCHO column data from space can thus be used effectively as a proxy for isoprene emission. From observed HCHO and isoprene profiles we find an HCHO molar yield from isoprene oxidation of 1.6 +/- 0.5, consistent with current chemical mechanisms. Clouds are the primary error source in the AMF calculation; errors in the HCHO vertical profile and aerosols have comparatively little effect. The mean bias and 1Q uncertainty in the GEOS-Chem AMF calculation increase from <1% and 15% for clear skies to 17% and 24% for half-cloudy scenes. With fitting errors, this gives an overall 1 Q error in HCHO satellite measurements of 25-31%. Retrieval errors, combined with uncertainties in the HCHO yield from isoprene oxidation, result in a 40% (1sigma) error in inferring isoprene emissions from HCHO satellite measurements.

Millet, Dylan B.↗

Performance of Al-Mn Transition-Edge Sensor Bolometers in SPT-3G

SPT-3G is a polarization-sensitive receiver, installed on the South Pole Telescope, that measures the anisotropy of the cosmic microwave background (CMB) from degree to arcminute scales. The receiver consists of ten 150-mm-diameter detector wafers, containing a total of similar to 16,000transition-edge sensor (TES) bolometers observing at 95, 150, and 220 GHz. During the 2018-2019 austral summer, one of these detector wafers was replaced by a new wafer fabricated with Al-Mn TESs instead of the Ti/Au design originally deployed for SPT-3G. We present the results of in-laboratory characterization and on-sky performance of this Al-Mn wafer, including electrical and thermal properties, optical efficiency measurements, and noise-equivalent temperature. In addition, we discuss and account for several calibration-related systematic errors that affect measurements made using frequency-domain multiplexing readout electronics.

Al-Mn↗

Correcting for Selection Biases in the Determination of the Hubble Constant from Time-Delay Cosmography

The time delay between multiple images of strongly lensed quasars has been used to infer the Hubble constant. The primary systematic uncertainty for time-delay cosmography is the mass-sheet transform (MST), which preserves the lensing observables while altering the inferred ⁠H 0 . The TDCOSMO collaboration used velocity dispersion measurements of lensed quasars and lensed galaxies to infer that mass sheets are present, which decrease the inferred H 0 by 8 per cent. Here, we test the assumption that the density profiles of galaxy–galaxy and galaxy–quasar lenses are the same. We use a composite star-plus-dark-matter mass profile for the parent deflector population and model the selection function for galaxy–galaxy and galaxy–quasar lenses. We find that a power-law density profile with an MST is a good approximation to a two-component mass profile around the Einstein radius, but we find that galaxy–galaxy lenses have systematically higher mass-sheet components than galaxy–quasar lenses. For individual systems, λ int correlates with the ratio of the half-light radius and Einstein radius of the lens. By propagating these results through the TDCOSMO hierarchical inference code, we find that H 0 is lowered by a further 3 per cent. Using a more recent measurement of velocity dispersions and our fiducial model for selection biases, we infer H 0 = 66 ± 4 (stat) ± 1 (model sys) ± 2 (measurement sys) km s -1 Mpc -1 for the TDCOSMO plus SLACS data set. The first residual systematic error is due to plausible alternative choices in modelling the selection function, and the second is an estimate of the remaining systematic error in the measurement of velocity dispersions for SLACS lenses. Accurate time-delay cosmography requires precise velocity dispersion measurements and accurate calibration of selection biases.

79 ASTRONOMY AND ASTROPHYSICS↗

Exploring model complexity in machine learned potentials for simulated properties

Abstract Machine learning (ML) enables the development of interatomic potentials with the accuracy of first principles methods while retaining the speed and parallel efficiency of empirical potentials. While ML potentials traditionally use atom-centered descriptors as inputs, different models such as linear regression and neural networks map descriptors to atomic energies and forces. This begs the question: what is the improvement in accuracy due to model complexity irrespective of descriptors? We curate three datasets to investigate this question in terms of ab initio energy and force errors: (1) solid and liquid silicon, (2) gallium nitride, and (3) the superionic conductor Li $$_{10}$$ 10 Ge(PS $$_{6}$$ 6 ) $$_{2}$$ 2 (LGPS). We further investigate how these errors affect simulated properties and verify if the improvement in fitting errors corresponds to measurable improvement in property prediction. By assessing different models, we observe correlations between fitting quantity (e.g. atomic force) error and simulated property error with respect to ab initio values. Graphical abstract

Rohskopf, A. (ORCID:0000000227128296)↗

Evaluation of a Sulfate Solubility Limit Greater Than 0.65 Weight Percent in Sludge Batch 10 Glasses

Previous laboratory-scale crucible testing with batch chemicals confirmed that the sulfate (SO 4 2- ) limit for Sludge Batch 10 (SB10) was 0.65 weight percent (wt.%) in glass. This limit signifies that 0.65 wt.% SO 4 2- can be retained in the glass without the formation of a sulfate phase. The Defense Waste Processing Facility imposes this constraint in the Material Tracking Program. Based on preliminary calculations to support the Material Tracking Program, it was anticipated that transfer volumes of the monosodium titanate/sludge solids (MST/SS) stream from the Salt Waste Processing Facility (SWPF) may need to be reduced to maintain projected sulfate concentrations below 0.65 wt.% in glass. Savannah River Mission Completion requested that the Savannah River National Laboratory perform additional sulfate testing to determine whether a sulfate solubility limit greater than 0.65 wt.% is feasible for SB10, which could allow for higher transfer volumes of the MST/SS stream. This report documents the results of the testing at higher sulfate concentrations for the glass composition region defined by the most recent SB10 projection (November 2022) and Frits 473 and 625. Frit 473 was recommended for SB10 and Frit 625 was used during SB9 processing and the SB9 to SB10 transition. A total of twenty-one glass compositions were developed based on the expected compositional variables, which include sludge-only (SO) and coupled processing with the SWPF, waste loading (WL), and frit composition. The target sulfate concentrations were varied from 0.65-0.85 wt.% at 32 and 40% WL. Each glass was prepared from reagent grade chemicals and melted at 1150 °C. Visual observations were used to confirm the presence of a sulfate salt phase on the cooled glass surfaces. Representative samples of each glass were submitted for chemical composition analysis by inductively coupled plasma-optical emission spectroscopy and Cs analysis by inductively coupled plasma-mass spectrometry. Overall the majority of mean measured values are consistent with the target values for each major oxide of interest with less than 5% error. The percent errors for the measured SO 4 2- concentrations are generally less than 10%, which is comparable with previous sulfate solubility study measurements and acceptable. Only the SO glasses based on Frit 625 formed a sulfate phase at a 0.80 wt.% SO 4 2- target concentration at both 32 and 40% WL. The remainder of the glasses did not form a sulfate layer. Due to the formation of the sulfate phase, the limit is conservatively set at 0.70 wt.% based on the measured sulfate concentrations of 0.71 wt.% and 0.75 wt.% for these two glasses. None of the SO or coupled operation glasses based on Frit 473 formed a sulfate salt phase, which supports a sulfate limit of 0.80 wt.%. The following SO 4 2- concentration limits are recommended during SO and coupled SB10 processing: (1) 0.70 wt.% during processing with Frit 625, and (2) 0.80 wt.% during processing with Frit 473.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Dispersion analysis and linear error analysis capabilities of the space vehicle dynamics simulation program

Previous error analyses conducted by the Guidance and Dynamics Branch of NASA have used the Guidance Analysis Program (GAP) as the trajectory simulation tool. Plans are made to conduct all future error analyses using the Space Vehicle Dynamics Simulation (SVDS) program. A study was conducted to compare the inertial measurement unit (IMU) error simulations of the two programs. Results of the GAP/SVDS comparison are presented and problem areas encountered while attempting to simulate IMU errors, vehicle performance uncertainties and environmental uncertainties using SVDS are defined. An evaluation of the SVDS linear error analysis capability is also included.

Snow, L. S.↗

Effect of stratospheric aerosol layers on the TOMS/SBUV ozone retrieval

An evaluation of the optical effects of stratospheric aerosol layers on total ozone retrieval from space by the TOMS/SBUV type instruments is presented here. Using the Dave radiative transfer model we estimate the magnitude of the errors in the retrieved ozone when polar stratospheric clouds (PSC's) or volcanic aerosol layers interfere with the measurements. The largest errors are produced by optically thick water ice PSC's. Results of simulation experiments on the effect of the Pinatubo aerosol cloud on the Nimbus-7 and Meteor-3 TOMS products are presented.

Torres, O.↗

Fluorescence Imaging of Rotational and Vibrational Temperature in a Shock Tunnel Nozzle Flow

Two-dimensional rotational and vibrational temperature measurements were made at the nozzle exit of a free-piston shock tunnel using planar laser-induced fluorescence. The Mach 7 flow consisted predominantly of nitrogen with a trace quantity of nitric oxide. Nitric oxide was employed as the probe species and was excited at 225 nm. Nonuniformities in the distribution of nitric oxide in the test gas were observed and were concluded to be due to contamination of the test gas by driver gas or cold test gas.The nozzle-exit rotational temperature was measured and is in reasonable agreement with computational modeling. Nonlinearities in the detection system were responsible for systematic errors in the measurements. The vibrational temperature was measured to be constant with distance from the nozzle exit, indicating it had frozen during the nozzle expansion.

Palma, Philip C.↗

An investigation of the effects of seeding in laser velocimeter systems

Errors in laser velocimeter measurements associated with the lag of seeding particles in subsonic and transonic flows were investigated experimentally and theoretically. In a low-speed flow, errors exceeding 5 percent were measured for particle diameters greater than 5 microns. In transonic flows, errors up to 60 percent were measured for particles with 2-3-micron diameters and up to 30 percent for 1-2-micron particles. A three-dimensional method was developed to determine the magnitude of errors due to the lag in seeding particle response based on a simplified particle force balance model and an empirical coefficient of drag model for spherical bodies. A one-dimensional version of this model was shown to be successful in correcting velocity measurements in both the subsonic and transonic flow regions.

Jones, Gregory S.↗

Active Mirror Predictive and Requirements Verification Software (AMP-ReVS)

This software is designed to predict large active mirror performance at various stages in the fabrication lifecycle of the mirror. It was developed for 1-meter class powered mirrors for astronomical purposes, but is extensible to other geometries. The package accepts finite element model (FEM) inputs and laboratory measured data for large optical-quality mirrors with active figure control. It computes phenomenological contributions to the surface figure error using several built-in optimization techniques. These phenomena include stresses induced in the mirror by the manufacturing process and the support structure, the test procedure, high spatial frequency errors introduced by the polishing process, and other process-dependent deleterious effects due to light-weighting of the mirror. Then, depending on the maturity of the mirror, it either predicts the best surface figure error that the mirror will attain, or it verifies that the requirements for the error sources have been met once the best surface figure error has been measured. The unique feature of this software is that it ties together physical phenomenology with wavefront sensing and control techniques and various optimization methods including convex optimization, Kalman filtering, and quadratic programming to both generate predictive models and to do requirements verification. This software combines three distinct disciplines: wavefront control, predictive models based on FEM, and requirements verification using measured data in a robust, reusable code that is applicable to any large optics for ground and space telescopes. The software also includes state-of-the-art wavefront control algorithms that allow closed-loop performance to be computed. It allows for quantitative trade studies to be performed for optical systems engineering, including computing the best surface figure error under various testing and operating conditions. After the mirror manufacturing process and testing have been completed, the software package can be used to verify that the underlying requirements have been met.

Basinger, Scott A.↗