Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “mcnp”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,351 records · Page 75

Narrowing transient testing pulse widths to enhance LWR RIA experiment design in the TREAT facility

The Transient Reactor Test (TREAT) Facility provided thousands of transient irradiations and plays a crucial role in nuclear-heated safety research. The facility’s flexible design and multi-mission nature saw historic experiments for numerous reactor fuels and transient types but was never specifically adapted to address very-brief pulse transients akin to postulated Light Water Reactor (LWR) Reactivity Initiated Accidents (RIA). Since the behaviors of fuel under these conditions depends strongly on energy input duration and resulting cladding time/temperature response under pellet cladding mechanical interactions, this three-year project was conceived to investigate new pulse-narrowing capabilities. Kinetic models showed incremental improvements for minor facility enhancements including increased reactivity step insertions (to initiate the power pulse) and slightly-increased transient rod drive speed for pulse termination (“clipping”). Replacing peak fuel assemblies, repositioning non-transient control rods to hold down the “hot side” of the core, and balancing against required excess reactivity needs, the limiting fuel assembly power can be reduced by ~20 %. Furthermore, this is a remarkable discovery of latent capability in TREAT, not only in enabling the subject capabilities for reduced pulse widths, but also significantly “uprating” the core’s transient energy capacity. Incremental improvements can likely enhance TREAT’s capability into BWR-relevant missions; briefer PWR pulse shapes can only be achieved with an advanced clipping system. Helium-3 ( 3 He) was found to offer the greatest benefits for clipping design and overall performance. A unique concept showed great promise for enabling a 3 He-based system with a reasonable cost; this design concept will likely become the focal point of future work.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Monte Carlo neutronics benchmarks on nuclear fuel depletion: A review

Monte Carlo (MC) neutronics codes are used widely for academic and industrial needs. Several schemes of coupling MC neutronics code with isotope generation and depletion code exist, which are used for performing nuclear fuel depletion simulations. These simulations can estimate the inventory of isotopes in neutron irradiated nuclear reactor fuel. However, the accuracy of these simulations shall be validated through experiments. MC codes are seldom validated by isotopic benchmarks compared to criticality benchmarks. This work compiles and analyzes the fuel depletion benchmarks and validations used to analyze the performance of MC-based fuel depletion neutronics codes. Analyses of these benchmarks and validations showed that the computed concentrations of 133 Cs, 135 Cs, 137 Cs, 148 Nd, 239 Pu, 240 Pu, and 241 Pu in the irradiated fuel by the depletion codes agreed with the measured values within 10% error. However, the computed concentrations of 125 Sb, 242 Cm, 243 Cm, 244 Cm, 245 Cm, and 246 Cm had errors more than 15% compared to the measured values. As a result, Ventina depletion code showed the most accurate predictions for the greatest number of isotope concentrations compared to ORIGEN2 and CINDER90.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Monte Carlo Simulations of the Water Draining Experiment of Giacint Critical Assembly

The MCNP6 computer program has been successfully extended to simulate reactor dynamics problems with moving parts of the geometries. Different from the dynamic method developed in other Monte Carlo codes, a movement scheme has been developed to account for the geometrical parts motion during the particle random walk. The MCNP6 computer program has been used to simulate two transient experiments of the Giacint critical assembly. The MCNP6 calculated total neutron flux was compared with that from the Serpent simulation. An excellent agreement was obtained between the results of the two Monte Caro computer programs. The MCNP6 calculated total neutron flux was also compared with the two measured transients. The MCNP6 results predicted a faster transient than the experimental data. The MCNP6 transient simulation was improved with an adjusted geometrical model which shifts the fuel rods slightly to match the measured reactivity worth due to the drained water. (c) 2021 Elsevier Ltd. All rights reserved.

MCNP, Moving Geometries, Monte Carlo Reactor Trans↗

$χ$-$MeRA$: Computationally efficient adaptive mesh refinement of Monte Carlo mesh based tallies

Here, the reactor physics community is always focused on reducing the computational time and memory required for simulations. $χ$-$MeRA$, which stands for flux-based-($χ$)-Mesh tally Refinement Adaptively, was built to reduce the computational time and memory required to solve the neutronics side of a multiphysics problem when compared to traditional methods for mesh based tallies in Monte Carlo (MC) simulations. $χ$-$MeRA$ couples a MC code with an adaptive mesh refinement (AMR) algorithm to take advantage of the accuracy of a MC code and the efficiency of an AMR algorithm. Also developed within $χ$-$MeRA$ was a set of metrics to assess the effects of the refinement on various parameters in the simulation space. For a plutonium sphere, $χ$-$MeRA$ shows a reduction in memory usage and computation time when compared to a fully refined mesh by a factor of 14.7 and 6.7, respectively. When compared to an unstructured mesh, improvement of 1.3 and 4.8 was achieved for memory usage and computation time. The development of $χ$-$MeRA$ helps solve the neutronics side of a multiphysics problem in a faster, more computationally efficient manner than traditional methods, and the final mesh created contains accurate results that can be passed onto the next physics code.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Characterization of the neutron flux during production of 18 F at a medical cyclotron and evaluation of the incidental neutron spectrum for neutron damage studies

The fast neutron spectrum was measured an irradiation position adjacent to two 18 F (fluorine-18) production targets at a medical cyclotron. The neutron spectrum was modeled using MCNP6 and experimentally determined using activation foils. A three-group neutron spectrum was determined using an over-determined least squares fitting method. The MCNP6 model results and measurements of the activation foils were used as input to unfold the neutron spectrum using the PNNL-STAYSL code. The neutron spectrum adjacent to the 18 F production target was evaluated for use in incidental experiments to evaluate neutron induced radiolysis of polyurethane and radiation hardness testing of electronics. The fast neutron flux near the 18 F target between the energies of 0.4 – 16.5 MeV was 1.8 – 3.0x10 9 n cm -2 s -1 . The neutron dose rate in polyurethane at the irradiation position was 2.8 cGy s -1 – 5.8 cGys -1 . The 1 MeV equivalent neutron flux was 2.4x10 9 n cm -2 s -1 – 4.0x10 9 n cm -2 s -1 .

18F-fluorodeoxyglucose↗

Characterization of 244 Cm Neutron Sources

There is a need to find a replacement for the 252 Cf sources currently used in Standards-based performance testing of neutron instrumentation. This is a result of its relatively short half-life, concerns about future availability and recent increases in cost. A potential replacement source, 244 Cm is evaluated in this study where two commercially available sources have been acquired and their neutron emission spectra measured using a pair of spectrometers. Both instruments showed the 244 Cm spontaneous neutron spectrum to be fully consistent with a MCNP6®-calculated spectrum using published Watt fission parameters for 244 Cm. In addition, the emission rate of the weaker 244 Cm source was established through a direct count rate comparison against a calibrated and similarly encapsulated 252 Cf source. The 244 Cm source emission rate was found to be in excellent agreement with value stated on the manufacturer's source certificate. It is concluded that 244 Cm would be an ideal replacement for 252 Cf based on its longer half-life (18.1 y) and its essentially identical neutron emission spectrum. In addition, 244 Cm sources are commercially available at reasonable cost.

244Cm↗

Shutdown dose rate analysis with the Shift Monte Carlo radiation transport code and modular verification workflow

Calculation of the shutdown dose rate is crucial for safe fusion reactor operations. The Rigorous-two-step (R2S) method is a method that requires connected neutron transport, activation, and gamma transport. Shift has integrated variance reduction with a deterministic solver Denovo, supports multiple geometry formats, and is scalable. These features make it an attractive transport solver choice for an R2S workflow. An R2S workflow for the Shift Monte Carlo code is developed and compared to the existing Oak Ridge National Laboratory Shutdown Dose Rate Code Suite (ORCS) workflow. Also, a Python framework for integrating two R2S workflows is developed to mix and match each step in the R2S workflow for improved collaboration and verification experience. In this study, results show that the Shift-Denovo R2S workflow and the ORCS workflow calculate the shutdown dose rate of the ITER Shutdown Dose Rate benchmark problem with an average relative error of 2.285%.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

In situ observation of irradiation-induced enhancement to the desorption pressure of zirconium hydride in a nuclear reactor

We quantify the effect of a nuclear-reactor environment on the hydrogen isotope equilibrium vapor pressure over pure zirconium and zirconium hydride. A vacuum-sealed capsule containing a zirconium foil with 6 atom% deuterium was irradiated at a neutron flux of ~10 14 cm -2 s -1 at the University of Missouri Research Reactor (MURR). The internal stainless-steel (SS) sample holder acted as the heat source via gamma absorption. To measure low desorption pressures in a high-flux environment, we developed a method to transduce pressure from the measured sample temperature during irradiation, calibrating with known deuterium pressures in unirradiated capsules at various heating powers using an internal filament-heated system designed to mimic irradiation-induced heating. Our temperature-pressure transduction method operates similarly to a Pirani or thermocouple pressure gauge. The in-reactor measurements revealed a roughly 4-fold enhancement in desorption pressure after only 6 h of irradiation (~2 × 10 18 cm -2 neutron fluence) compared to thermal desorption in control experiments, indicating a nonthermal contribution from neutron irradiation. The slower temperature/pressure stabilization rate in the reactor suggests that desorption pressure enhancement increases with neutron fluence. Further, this enhancement signifies increased solubility of hydrogen isotopes in zirconium during irradiation. We propose that high-energy neutron collisions with hydrogen isotopes in hydrides lead to their decomposition at lower temperatures, supersaturating the surrounding αZr lattice and resulting in higher desorption pressure, which continues to rise as more hydrides dissolve with increasing neutron fluence.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Evaluation of Delayed Critical ORNL Unreflected HEU Metal Sphere (ORSphere)

In 1971 and 1972 experimenters at the Oak Ridge Critical Experiment Facility performed critical experiments using an unreflected metal sphere of highly enriched uranium (HEU). The sphere used for the criticality experiments, originally used for neutron leakage spectrum measurements by General Atomic Company, consisted of three main parts and were assembled with a vertical assembly machine. Two configurations were tested. The first was nearly spherical with a nominal radius of 3.467 inches and had a reactivity of 68.1 ± 2.0 cents. The sphere parts were then re-machined as a sphere with a nominal radius of 3.4425 inches. This assembly had a reactivity of -23 cents. The method, dimensions, and uncertainty of the critical experiment were extensively recorded and documented. The original purpose of the experiments was for comparison to GODIVA I experiments. The ORNL unreflected HEU Metal Spheres have been evaluated for inclusion in the International Handbook of Evaluated Criticality Safety Benchmark Experiments (scheduled for inclusion in the September 2013 edition).

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Evaluation of material accountancy techniques for 233 Pa from thorium nuclear fuels

Thorium is a promising alternative to uranium as nuclear fuel with advantages such as higher abundance, lower production of long-lived transuranic elements, and potentially better proliferation resistance. However, thorium presents a potential pathway for proliferation where produced 233 Pa can be diverted for the clandestine production of safeguarded 233 U. To prevent this, the ability to detect and measure 233 Pa must be assessed. This paper reviews several nuclear material accountancy techniques to determine their suitability for detecting 233 Pa extracted from irradiated thorium fuel. Hybrid K-edge densitometry and passive gamma spectroscopy have been found to be the best options based on technology maturity, cost, accuracy, and acquisition time. Thorium can be used in various reactor designs such as pressurized water reactors (PWRs), Canada deuterium uranium (CANDU) reactors, and molten salt reactors (MSRs). Therefore, thorium-uranium oxide fueling was modeled for three representative reactors (PWR, CANDU, MSR), burning the fuel to 47 GWd/MTHM for PWR, 19 GWd/MTHM for CANDU, and at a steady power of 52.711 MW/MTHM for MSR. Within each model, the protactinium element in the used fuel was extracted and its isotopic content analyzed. Simulated results indicated that 233 Pa can be detected using passive gamma spectroscopy in each fuel type at all decay times (0–300 days) following separation.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Neutron Detection Alternatives to 3He for National Security Applications

One of the main uses for 3He is in gas proportional counters for neutron detection. Large radiation detection systems deployed for homeland security and proliferation detection applications use such systems. Due to the large increase in use of 3He for homeland security and basic research, the supply has dwindled, and can no longer meet the demand. This has led to the search for an alternative technology to replace the use of 3He-based neutron detectors. In this paper, we review the testing of currently commercially available alternative technologies for neutron detection in large systems used in various national security applications.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Electronic neutron sources for compensated porosity well logging

The viability of replacing Americium–Beryllium (Am–Be) radiological neutron sources in compensated porosity nuclear well logging tools with D–T or D–D accelerator-driven neutron sources is explored. The analysis consisted of developing a model for a typical well-logging borehole configuration and computing the helium-3 detector response to varying formation porosities using three different neutron sources (Am–Be, D–D, and D–T). The results indicate that, when normalized to the same source intensity, the use of a D–D neutron source has greater sensitivity for measuring the formation porosity than either an Am–Be or D–T source. The results of the study provide operational requirements that enable compensated porosity well logging with a compact, low power D–D neutron generator, which the current state-of-the-art indicates is technically achievable.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Cross-correlation measurements with the EJ-299-33 plastic scintillator

New organic–plastic scintillation compositions have demonstrated pulse-shape discrimination (PSD) of neutrons and gamma rays. We present cross-correlation measurements of 252 Cf and mixed uranium–plutonium oxide (MOX) with the EJ-299-33 plastic scintillator. For comparison, equivalent measurements were performed with an EJ-309 liquid scintillator. Offline, digital PSD was applied to each detector. These measurements show that EJ-299-33 sacrifices a factor of 5 in neutron–neutron efficiency relative to EJ-309, but could still utilize the difference in neutron–neutron efficiency and neutron single-to-double ratio to distinguish 252 Cf from MOX. These measurements were modeled with MCNPX-PoliMi, and MPPost was used to convert the detailed collision history into simulated cross-correlation distributions. MCNPX-PoliMi predicted the measured 252 Cf cross-correlation distribution for EJ-309 to within 10%. Greater photon uncertainty in the MOX sample led to larger discrepancy in the simulated MOX cross-correlation distribution. In conclusion, the modeled EJ-299-33 plastic also gives reasonable agreement with measured cross-correlation distributions, although the MCNPX-PoliMi model appears to under-predict the neutron detection efficiency.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Organic Scintillator Detector Response Simulations with DRiFT

Here, this work presents the organic scintillation simulation capabilities of DRiFT, a post-processing Detector Response Function Toolkit for MCNPR output. DRiFT is used to create realistic scintillation detector response functions to incident neutron and gamma mixed- field radiation. As a post-processing tool, DRiFT leverages the extensively validated radiation transport capabilities of MCNPR ® 6, which also provides the ability to simulate complex sources and geometries. DRiFT is designed to be flexible, it allows the user to specify scintillator material, PMT type, applied PMT voltage, and quenching data used in simulations. The toolkit's capabilities, which include the generation of pulse shape discrimination plots and full-energy detector spectra, are demonstrated in a comparison of measured and simulated neutron contributions from 252 Cf and PuBe, and photon spectra from 22 Na and 228 Th sources. DRiFT reproduced energy resolution effects observed in EJ-301 measurements through the inclusion of scintillation yield variances, photon transport noise, and PMT photocathode and multiplication noise.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Numerical integration of detector response functions via Monte Carlo simulations

Calculations of detector response functions are complicated because they include the intricacies of signal creation from the detector itself as well as a complex interplay between the detector, the particle-emitting target, and the entire experimental environment. As such, these functions are typically only accessible through time-consuming Monte Carlo simulations. Furthermore, the output of thousands of Monte Carlo simulations can be necessary in order to extract a physics result from a single experiment. Here we describe a method to obtain a full description of the detector response function using Monte Carlo simulations. We also show that a response function calculated in this way can be used to create Monte Carlo simulation output spectra a factor of ~1000× faster than running a new Monte Carlo simulation. A detailed discussion of the proper treatment of uncertainties when using this and other similar methods is provided as well. Here, this method is demonstrated and tested using simulated data from the Chi-Nu experiment, which measures prompt fission neutron spectra at the Los Alamos Neutron Science Center.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗