Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “image segmentation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,351 records · Page 75

Development of low temperature fuel cell holders for Operando x-ray micro and nano computed tomography to visualize water distribution

Abstract Synchrotron x-ray imaging techniques, like x-ray computed tomography (CT) and radiography have proven instrumental in expanding the communities knowledge of complex transport and reaction kinetics in electrochemical devices such as fuel cells and electrolyzers. This work presents the development of novel x-ray CT imaging techniques for operando visualization of water within low temperature fuel cells at spatial resolutions spanning the micro and nano scales. The design of operando sample holders, for both micro x-ray CT and nano CT experiments is described in depth, and prototypes of these sample holders were evaluated across a set of requirements, the most important of which are x-ray transmissibility, electrical conductivity and mechanical stability. Water segmentation from micro x-ray CT data was enabled by an image subtraction method, where the image without water is subtracted from the one with water. Through iterative experimentations, the operando nano CT cell was developed to optimize mechanical compression, electric conductivity and gas flow. While three-dimensional fuel cell reconstructions were shown possible, there remain challenges to overcome at typical lower energies (8 keV) due to beam damage, whereas it is not as significant for higher energies (>17.5 keV).

Kulkarni, Devashish↗

Image Fusion Guidance with Pre-procedural CT with Real-Time Fluoroscopy for Adrenal Venous Sampling

PurposeTo assess the effectiveness of image fusion guidance (IF) with pre-procedural computed tomography (CT) with intraprocedural fluoroscopy for adrenal venous sampling (AVS).Materials and MethodsAVS before and after ACTH stimulation including bilateral segmental sampling of effluent tributaries was performed in 62 patients with IF. A 3D volume rendering image, including adrenal glands and veins extracted from previously obtained contrast-enhanced CT images, was manually registered to the real-time X-ray fluoroscopy. The technical success rates, procedure time, radiation exposure, and volume of contrast medium used were compared with 49 patients who underwent AVS without IF.ResultsNo significant differences in the technical success rates with and without IF were observed (98.4 vs. 91.8% for the right adrenal veins, p = 0.168, and 98.4 vs. 100% for the left adrenal veins, p = 1.000). The procedure time with IF was significantly shorter than that without IF (95.6 ± 18.8 vs. 108.4 ± 20.0 min, p = 0.001). The total dose-area product with IF was significantly lower than that without IF (43.1 ± 30.7 vs. 72.2 ± 45.3 Gy cm{sup 2}, p < 0.001). The contrast medium volume used with IF was significantly lower than that without IF (54.6 ± 21.9 vs. 65.7 ± 27.6 mL, p = 0.020).ConclusionsAlthough the contribution to improving the technical success rates was small in our study, IF can effectively reduce procedure time, radiation exposure, and volume of contrast medium during AVS.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Demonstration of Multi-Star Wavefront Control for WFIRST, Habex, and LUVOIR

Coronagraphic instruments will enable direct imaging of dim planetary companions around nearby stars. The majority of nearby FGK stars are located in multi-star systems, including the Alpha Centauri stars, which may represent the best quality targets available for spectroscopic characterization due to their proximity and brightness. However, a binary system exhibits additional leakage from the o -axis companion star that may be brighter than the target exoplanet. Multi-Star Wavefront Control (MSWC) is a wavefront-control technique that allows simultaneous suppression of starlight of both stars in a binary system. MSWC would thus enable direct imaging of circumstellar planets in binary star systems such as Alpha Centauri. MSWC is compatible with a wide suite of planned coronagraphic instruments for future space missions. As part of the technology demonstration e orts for MSWC, the rst milestone results are presented here demonstrating (via computer simulations), high-contrast imaging capabilities of multi-star systems for several instruments including: [1] the upcoming WFIRST and its CGI demonstrator, [2] the HABitable Worlds EXplorer (Habex) mission concept, [3] the segmented Large UV/Optical/IR (LUVOIR) mission concept, and [4] a small-aperture Alpha Centauri direct-imager mission concept. For each of these missions, a baseline coronagraph option planned for the mission will be adopted and instrument baseline performance will be compared for single-star wavefront control.

Sirbu, Dan↗

Generalization Across Experimental Parameters in Neural Network Analysis of High-Resolution Transmission Electron Microscopy Datasets

Neural networks are promising tools for high-throughput and accurate transmission electron microscopy (TEM) analysis of nanomaterials, but are known to generalize poorly on data that is “out-of-distribution” from their training data. Given the limited set of image features typically seen in high-resolution TEM imaging, it is unclear which images are considered out-of-distribution from others. Here, we investigate how the choice of metadata features in the training dataset influences neural network performance, focusing on the example task of nanoparticle segmentation. We train and validate neural networks across curated, experimentally collected high-resolution TEM image datasets of nanoparticles under various imaging and material parameters, including magnification, dosage, nanoparticle diameter, and nanoparticle material. Overall, we find that our neural networks are not robust across microscope parameters, but do generalize across certain sample parameters. Additionally, data preprocessing can have unintended consequences on neural network generalization. Our results highlight the need to understand how dataset features affect deployment of data-driven algorithms.

42 ENGINEERING↗

WE-DE-BRA-07: Megavoltage Spectral Imaging with a Layered Detector

Purpose: The aim of the current work is to investigate the feasibility of megavoltage spectral imaging using a multiple layered detector for enhancement of low contrast detectability through material segmentation and discrimination (such as bone, markers and metal implants). Potentially the technique can be applied to improve detection and reduce dose in Megavoltage Cone Beam Computed Tomography (MV-CBCT). Methods: Experiments were performed with a prototype multi-layer imager (MLI) which has higher detective efficiency and lower noise characteristics than conventional Electronic Portal Imaging Devices (EPIDs). Images of a solid water phantom were acquired at 2.5 MV, 6MV and 6MV without flattening filter (FFF). The following materials were placed within a stack of solid water: aluminum, copper and gold. Material separation was assessed based on Contrast-to-Noise Ratio (CNR) of the weighted image, formed by a weighted subtraction of the images from two layers of the MLI. A range of weighting factors were investigated for material separation. Results: CNR can be minimized for each material by appropriate selection of the subtraction weighting factor. This is equivalent to a selective subtraction of specific materials from the image. Using multiple layers simultaneously also decreases the dose requirement and removes any registration errors. The minimum CNR for aluminum, copper and gold at the weighted image formed with 2.5MV was obtained at weighting factors equal to 0.92, 0.76 and 0.64 respectively. The corresponding values at 6MVFFF were 0.99, 0.92 and 0.78 respectively. Conclusion: In the current work, an MV spectral imaging feasibility study was attempted using a novel multi-layer prototype EPID imager. Initial results suggest that material separation based on spectral differences between different layers is possible. This spectral imaging technique has potential advantages in MV-CBCT for real-time target tracking, patient set-up imaging and adaptive radiotherapy. The project was supported, partially, by a grant from Varian Medical Systems, Inc., and Award No. R01CA188446-01 from the National Cancer Institute. The content is solely the responsibility of the authors and does not necessarily represent the official views of the National Cancer Institute or the National Institutes of Health.

60 APPLIED LIFE SCIENCES↗

TH-AB-202-12: The First Clinical Implementation of a Real-Time Six Degree of Freedom Tracking System During Radiation Therapy

Purpose: In current practice, imaging is typically performed prior to treatment; the cancer target motion during treatment is unknown. We present the first clinical implementation of real time Kilovoltage Intrafraction Monitoring (KIM) system which tracks the cancer target translational and rotational motions during treatment. Methods: KIM technology: KIM estimates the 3D position of the target tumour based on segmented 2D positions of the three implanted fiducials in each of the kV images (125 kV, 10 mA at 11 fps) taken continuously during the treatment arc. The 2D-3D target estimation is based on a probability distribution function, obtained during pre-treatment CBCT. Rotations about each axis with the centroid of the markers as the pivot were calculated using the iterative closest point algorithm in real time. Patient: A patient with prostate adenocarcinoma undergoing stereotactic body radiotherapy (SBRT) with 36.25 Gy delivered in 5 fractions (Varian TrueBeam, 6X, VMAT) was enrolled in the study. The trial complies with Australian ethical and regulatory standards. Results: Of the 5 fractions of treatment the patient received, KIM was utilised successfully in 4 fractions with 3 couch shifts due to large persistent prostate movements (>2mm for more than 5 seconds). KIM translational accuracy and precision in comparison with post treatment kV-MV triangulation are 0.28±0.59 mm, −0.19±0.25 mm and 0.23±0.69 mm in the Left-Right, Superior-Inferior and Anterior-Posterior directions, respectively. KIM rotational accuracy as compared with triangulation is: 0.429°±2.22°, −0.44°±4.7° and 0.06°±1.08° in the roll, pitch and yaw direction, respectively. Conclusion: The first six degree of freedom KIM system was successfully implemented clinically. The presented KIM system has sub-millimeters accuracy and precision in all three translational axes, and less than 1° of mean error in all three rotational axes. Acknowledgement: This work is supported by Cancer Australia grants APPXXX, APPYYY.

60 APPLIED LIFE SCIENCES↗

Investigation of Primary Mirror Segment's Residual Errors for the Thirty Meter Telescope

The primary mirror segment aberrations after shape corrections with warping harness have been identified as the single largest error term in the Thirty Meter Telescope (TMT) image quality error budget. In order to better understand the likely errors and how they will impact the telescope performance we have performed detailed simulations. We first generated unwarped primary mirror segment surface shapes that met TMT specifications. Then we used the predicted warping harness influence functions and a Shack-Hartmann wavefront sensor model to determine estimates for the 492 corrected segment surfaces that make up the TMT primary mirror. Surface and control parameters, as well as the number of subapertures were varied to explore the parameter space. The corrected segment shapes were then passed to an optical TMT model built using the Jet Propulsion Laboratory (JPL) developed Modeling and Analysis for Controlled Optical Systems (MACOS) ray-trace simulator. The generated exit pupil wavefront error maps provided RMS wavefront error and image-plane characteristics like the Normalized Point Source Sensitivity (PSSN). The results have been used to optimize the segment shape correction and wavefront sensor designs as well as provide input to the TMT systems engineering error budgets.

warping harness↗

SU-F-J-112: Clinical Feasibility Test of An RF Pulse-Based MRI Method for the Quantitative Fat-Water Segmentation

Purpose: Quantitative fat-water segmentation is important not only because of the clinical utility of fat-suppressed MRI images in better detecting lesions of clinical significance (in the midst of bright fat signal) but also because of the possible physical need, in which CT-like images based on the materials’ photon attenuation properties may have to be generated from MR images; particularly, as in the case of MR-only radiation oncology environment to obtain radiation dose calculation or as in the case of hybrid PET/MR modality to obtain attenuation correction map for the quantitative PET reconstruction. The majority of such fat-water quantitative segmentations have been performed by utilizing the Dixon’s method and its variations, which have to enforce the proper settings (often predefined) of echo time (TE) in the pulse sequences. Therefore, such methods have been unable to be directly combined with those ultrashort TE (UTE) sequences that, taking the advantage of very low TE values (∼ 10’s microsecond), might be beneficial to directly detect bones. Recently, an RF pulse-based method (http://dx.doi.org/10.1016/j.mri.2015.11.006), termed as PROD pulse method, was introduced as a method of quantitative fat-water segmentation that does not have to depend on predefined TE settings. Here, the clinical feasibility of this method is verified in brain tumor patients by combining the PROD pulse with several sequences. Methods: In a clinical 3T MRI, the PROD pulse was combined with turbo spin echo (e.g. TR=1500, TE=16 or 60, ETL=15) or turbo field echo (e.g. TR=5.6, TE=2.8, ETL=12) sequences without specifying TE values. Results: The fat-water segmentation was possible without having to set specific TE values. Conclusion: The PROD pulse method is clinically feasible. Although not yet combined with UTE sequences in our laboratory, the method is potentially compatible with UTE sequences, and thus, might be useful to directly segment fat, water, bone and air.

60 APPLIED LIFE SCIENCES↗

NASA Today - Mars Observer Segment (Part 4 of 6)

This videotape consists of eight segments from the NASA Today News program. The first segment is an announcement that there was no date set for the launch of STS-51, which had been postponed due to mechanical problems. The second segment describes the MidDeck Dynamic Experiment Facility. The third segment is about the scheduled arrival of the Mars Observer at Mars, it shows an image of Mars as seen from the approaching Observer spacecraft, and features an animation of the approach to Mars, including the maneuvers that are planned to put the spacecraft in the desired orbit. The fourth segment describes a discovery from an infrared spectrometer that there is nitrogen ice on Pluto. The fifth segment discusses the Aerospace for Kids (ASK) program at the Goddard Space Flight Center (GSFC). The sixth segment is about the high school and college summer internship programs at GSFC. The seventh segment announces a science symposium being held at Johnson Space Center. The last segment describes the National Air and Space Museum and NASA's cooperation with the Smithsonian Institution.

Source record↗

Improved dosimetry for targeted radionuclide therapy using nonrigid registration on sequential SPECT images

Purpose: Voxel-level and patient-specific 3D dosimetry for targeted radionuclide therapy (TRT) typically involves serial nuclear medicine scans. Misalignment of the images can result in reduced dosimetric accuracy. Since the scans are typically performed over a period of several days, there will be patient movement between scans and possible nonrigid organ deformation. This work aims to implement and evaluate the use of nonrigid image registration on a series of quantitative SPECT (QSPECT) images for TRT dosimetry. Methods: A population of 4D extended cardiac torso phantoms, comprised of three In-111 Zevalin biokinetics models and three anatomical variations, was generated based on the patient data. The authors simulated QSPECT acquisitions at five time points. At each time point, individual organ and whole-body deformation between scans were modeled by translating/rotating organs and the body up to 5°/voxels, keeping ≤5% difference in organ volume. An analytical projector was used to generate realistic noisy projections for a medium energy general purpose collimator. Projections were reconstructed using OS-EM algorithm with geometric collimator detector response, attenuation, and scatter corrections. The QSPECT images were registered using organ-based nonrigid image registration method. The cumulative activity in each voxel was obtained by integrating the activity over time. Dose distribution images were obtained by convolving the cumulative activity images with a Y-90 dose kernel. Dose volume histograms (DVHs) for organs-of-interest were analyzed. Results: After nonrigid registration, the mean differences in organ doses compared to the case without misalignment were improved from (−15.50 ± 5.59)% to (−2.12 ± 1.05)% and (−7.28 ± 2.30)% to (−0.23 ± 0.71)% for the spleen and liver, respectively. For all organs, the cumulative DVHs showed improvement after nonrigid registration and the normalized absolute error of differential DVHs ranged from 6.79% to 22.70% for liver and 26.00% to 39.70% for spleen with different segmentation methods. Conclusions: These results demonstrated that nonrigid registration of sequential QSPECT images is feasible for TRT and improves the accuracy of 3D dosimetry.

60 APPLIED LIFE SCIENCES↗

Computer Vision Pipeline for Image Analysis for Freeze‐Fracture Electron Microscopy: Rosette Cellulose Synthase Complexes Case

In materials science, plant biology, agriculture, and environmental research, the automated analysis of high-magnification, complex microscopy images, such as those generated by freeze-fracture electron microscopy (FF-TEM), remains a critical challenge that limits the scalability of data interpretation. We present a deep learning computer vision pipeline for high-throughput detection and morphological characterization analysis of cellulose synthase complexes (CSCs, or rosettes) in FF-TEM images. The pipeline integrates preprocessing, detection, human-in-the-loop verification, and semantic segmentation to quantify features such as rosette diameter and inter-lobe spacing. The approach was trained and tested on a curated dataset of high-resolution FF-TEM micrographs of Physcomitrium patens, expanded via strategic tiling and augmentation to over 650 images. We compare YOLOv8 and YOLOv9 architectures and demonstrate that YOLOv9 achieves superior performance in both localization accuracy (mAP50-95 = 0.854) and inference speed. The resulting distributions revealed biological variability consistent with prior manual studies, validating the approach for high-throughput applications. Our results show that the pipeline achieves human-expert level accuracy while dramatically reducing analysis time, enabling scalable, reproducible structural characterization of intramembrane protein complexes. The pipeline is broadly applicable to other domains requiring precise interpretation of complex microscopy data and establishes a foundation for future artificial intelligence (AI)-assisted workflows in biological imaging.

59 BASIC BIOLOGICAL SCIENCES↗

First Clinical Release of an Online, Adaptive, Aperture-Based Image-Guided Radiotherapy Strategy in Intensity-Modulated Radiotherapy to Correct for Inter- and Intrafractional Rotations of the Prostate

Purpose: We developed and evaluated a correction strategy for prostate rotations using direct adaptation of segments in intensity-modulated radiotherapy (IMRT). Method and Materials: Implanted fiducials (four gold markers) were used to determine interfractional translations, rotations, and dilations of the prostate. We used hybrid imaging: The markers were automatically detected in two pretreatment planar X-ray projections; their actual position in three-dimensional space was reconstructed from these images at first. The structure set comprising prostate, seminal vesicles, and adjacent rectum wall was transformed accordingly in 6 degrees of freedom. Shapes of IMRT segments were geometrically adapted in a class solution forward-planning approach, derived within seconds on-site and treated immediately. Intrafractional movements were followed in MV electronic portal images captured on the fly. Results: In 31 of 39 patients, for 833 of 1013 fractions (supine, flat couch, knee support, comfortably full bladder, empty rectum, no intraprostatic marker migrations >2 mm of more than one marker), the online aperture adaptation allowed safe reduction of margins clinical target volume-planning target volume (prostate) down to 5 mm when only interfractional corrections were applied: Dominant L-R rotations were found to be 5.3 Degree-Sign (mean of means), standard deviation of means {+-}4.9 Degree-Sign , maximum at 30.7 Degree-Sign . Three-dimensional vector translations relative to skin markings were 9.3 {+-} 4.4 mm (maximum, 23.6 mm). Intrafractional movements in 7.7 {+-} 1.5 min (maximum, 15.1 min) between kV imaging and last beam's electronic portal images showed further L-R rotations of 2.5 Degree-Sign {+-} 2.3 Degree-Sign (maximum, 26.9 Degree-Sign ), and three-dimensional vector translations of 3.0 {+-}3.7 mm (maximum, 10.2 mm). Addressing intrafractional errors could further reduce margins to 3 mm. Conclusion: We demonstrated the clinical feasibility of an online adaptive image-guided, intensity-modulated prostate protocol on a standard linear accelerator to correct 6 degrees of freedom of internal organ motion, allowing safe and straightforward implementation of margin reduction and dose escalation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A “loop” shape descriptor and its application to automated segmentation of airways from CT scans

Purpose: A novel shape descriptor is presented to aid an automated identification of the airways depicted on computed tomography (CT) images. Methods: Instead of simplifying the tubular characteristic of the airways as an ideal mathematical cylindrical or circular shape, the proposed “loop” shape descriptor exploits the fact that the cross sections of any tubular structure (regardless of its regularity) always appear as a loop. In implementation, the authors first reconstruct the anatomical structures in volumetric CT as a three-dimensional surface model using the classical marching cubes algorithm. Then, the loop descriptor is applied to locate the airways with a concave loop cross section. To deal with the variation of the airway walls in density as depicted on CT images, a multiple threshold strategy is proposed. A publicly available chest CT database consisting of 20 CT scans, which was designed specifically for evaluating an airway segmentation algorithm, was used for quantitative performance assessment. Measures, including length, branch count, and generations, were computed under the aid of a skeletonization operation. Results: For the test dataset, the airway length ranged from 64.6 to 429.8 cm, the generation ranged from 7 to 11, and the branch number ranged from 48 to 312. These results were comparable to the performance of the state-of-the-art algorithms validated on the same dataset. Conclusions: The authors’ quantitative experiment demonstrated the feasibility and reliability of the developed shape descriptor in identifying lung airways.

60 APPLIED LIFE SCIENCES↗

Fabrication and temperature-dependent magnetic properties of one-dimensional multilayer Au–Ni–Au–Ni–Au nanowires

Multilayer Au–Ni–Au–Ni–Au nanowires with a controlled diameter of ∼100 nm were synthesized by electrochemical deposition in porous alumina templates. The length of each Ni-segment was controlled up to ∼230 nm, while the length of the Au segment sandwiched between two Ni segments was ∼180 nm. X-ray diffraction patterns and energy-dispersive X-ray spectra confirmed the formation of purely crystalline nanowires. The magnetic properties of the multilayer Au–Ni–Au–Ni–Au nanowires were investigated in the temperature range 2–300 K. Room-temperature magnetic hysteresis confirmed the ferromagnetic nature of the nanowires. The plot of coercivity as a function of temperature (from 2 to 300 K) followed law applicable for ferromagnetic nanostructures. The magnetization tended to increase as the temperature decreased, following the modified Bloch's law similar to ferromagnetic nanoparticles. - Graphical abstract: (a) SEM image of Au–Ni–Au–Ni–Au nanowire with 230 nm Ni segment length and 180 nm Au sandwiched between Ni segments (b) Kneller's law (c) Bloch's law Display Omitted - Highlights: • Electrochemical fabrication of Au–Ni–Au–Ni–Au nanowires in alumina templates. • Formation of beadlike structure of Ni segments. • Coercivity versus T follows Kneller's law for ferromagnetic materials. • Magnetization as a function of temperature follows the modified Bloch's law.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A software-based system which produces SEASAT SAR imagery

A digital processing algorithm and its associated system design for producing images from SEASAT synthetic aperture radar (SAR) data is described. The proposed system uses the fast Fourier transform approach to perform the two dimensional correlation process. The range migration problem can be alleviated by approximating the locus of echoes from a point target by several linear segments. Data corresponding to each segment are correlated separately and the results are coherently summed to produce full resolution images. This processing approach exhibits high computation efficiency and simple processing control functions. It is particularly attractive for software implementation based on general purpose computers. Results of this implementation and examples of digitally correlated SEASAT SAR imagery are discussed.

Wu, C.↗

Thematic Mapper geometric correction processing

The Thematic Mapper Image Processing System is described from the point of view of geometric correction. The system performance requirements are discussed, and the Landsat-D flight segment is described. The ground processing and overall geometric system performance is addressed. Those aspects of the Thematic Mapper Image Processing System that differ significantly from those of the MSS System are emphasized.

Beyer, E. P.↗

Segmentation of tomography datasets using 3D convolutional neural networks

Dendritic microstructures are ubiquitous in nature and are the primary solidification morphologies in metallic materials. Techniques such as X-ray computed tomography (XCT) have provided new insights into dendritic phase transformation phenomena. However, manual identification of dendritic morphologies in microscopy data can be both labor intensive and potentially ambiguous. The analysis of 3D datasets is particularly challenging due to their large sizes (terabytes) and the presence of artifacts scattered within the imaged volumes. Here, in this study, we trained 3D convolutional neural networks (CNNs) to segment 3D datasets. Three CNN architectures were investigated, including a new version of FCDenseNet which we extended to 3D. We show that using hyperparameter optimization (HPO) and fine-tuning techniques, both 2D and 3D CNN architectures outperform the previous state of the art. The 3D U-Net architecture trained in this study produced the best segmentations according to quantitative metrics (intersection-over-union of 95.56% and a boundary displacement error of 0.58 pixels), while 3D FCDense produced the smoothest boundaries and best segmentations according to visual inspection. The trained 3D CNNs are able to segment entire 852 × 852 × 250 voxel 3D volumes in only ~60 s, thus hastening the progress towards a deeper understanding of phase transformation phenomena such as dendritic solidification.

36 MATERIALS SCIENCE↗

Developmental Cryogenic Active Telescope Testbed, a Wavefront Sensing and Control Testbed for the Next Generation Space Telescope

As part of the technology validation strategy of the next generation space telescope (NGST), a system testbed is being developed at GSFC, in partnership with JPL and Marshall Space Flight Center (MSFC), which will include all of the component functions envisioned in an NGST active optical system. The system will include an actively controlled, segmented primary mirror, actively controlled secondary, deformable, and fast steering mirrors, wavefront sensing optics, wavefront control algorithms, a telescope simulator module, and an interferometric wavefront sensor for use in comparing final obtained wavefronts from different tests. The developmental. cryogenic active telescope testbed (DCATT) will be implemented in three phases. Phase 1 will focus on operating the testbed at ambient temperature. During Phase 2, a cryocapable segmented telescope will be developed and cooled to cryogenic temperature to investigate the impact on the ability to correct the wavefront and stabilize the image. In Phase 3, it is planned to incorporate industry developed flight-like components, such as figure controlled mirror segments, cryogenic, low hold power actuators, or different wavefront sensing and control hardware or software. A very important element of the program is the development and subsequent validation of the integrated multidisciplinary models. The Phase 1 testbed objectives, plans, configuration, and design will be discussed.

Leboeuf, Claudia M.↗