Development of Prototypical District-Scale Models: Preprint

The U.S. has set the climate goal to achieve net-zero greenhouse gas emissions by 2050. District-scale solutions, which include scale-specific opportunities for energy and emissions savings, can be investigated and implemented to help accelerate decarbonization and progress toward this goal. However, there is currently a lack of district-scale models of buildings and community energy systems that can be used to evaluate potential district-scale technologies and strategies across a range of representative community types. This initial work aims to define and develop prototype district models that can be adapted to support the planning, design, and operation of buildings and energy systems in districts considering the complexity and interactions of diverse building loads, weather impacts, distributed energy resources (e.g., PV, EV, electric and thermal energy storage), electric and thermal grid systems, and pricing signals. An overall workflow for developing these prototype district models is established. Stakeholders and potential users of the prototype district models provided technical feedback. The specifications of the selected high priority districts were defined and documented in a scorecard format. An example prototype district model was implemented with the URBANoptTM platform workflows. A case study was performed to demonstrate the model application.

district↗

Adaptive learning-driven high-throughput synthesis of oxygen reduction reaction Fe–N–C electrocatalysts

Reducing human reliance on inefficient energy systems and fossil fuels has become more urgent due to the consequences of global climate change. However, traditional trial-and-error approaches have hampered our ability to accelerate the discovery and implementation of functional materials for efficient energy conversion devices, such as polymer electrolyte fuel cells (PEFCs). To address this, we develop an adaptive learning framework that integrates machine learning and state-of-the-art capabilities in high-throughput synthesis to achieve expedited optimization of iron-nitrogen-carbon PEFC oxygen reduction reaction (ORR) electrocatalysts. We use statistical inference, uncertainty quantification, and global optimization to build a computational design-of-experiment tool that identifies the optimum compositions to be investigated next to reduce the demands placed on experimental materials discovery. We benchmark the ability of the proposed strategy to discover optimum catalyst synthesis conditions in a six-dimensional search space when starting with a thirty-six-sample database. By following the adaptive learning strategy, we synthesize fourteen new catalysts from approximately ten billion unique compositions and discover four catalysts that outperform all original samples. The best machine learning-optimized catalyst is 33% more active than the highest-performing one in the initial database, showing an ORR activity seven times larger than those typically reported for the same class of materials.

36 MATERIALS SCIENCE↗

Split HPWHs as an Efficient Solution for Multifamily Buildings with In-Unit Water Heaters

A quarter of all housing units in the United States are found in multifamily buildings, but few efficiency innovations have been made to improve electric water heating systems in this building type. Domestic hot water in multifamily buildings can either be provided by a large central water heater or smaller in-unit water heaters. Integrated heat pump water heaters that are installed in single-family homes are often a poor fit for individual multifamily units because the water heaters are often located in small internal closets. This confined space can limit the airflow to the heat pump, and the cold exhaust air can cause discomfort and reduced efficiency. Split CO2 HPWHs separate the tank from the heat pump, which allows for installation location flexibility. Further, CO2 heat pumps can operate under colder ambient conditions, making them a better fit for multifamily units across a wide range of climate regions. As part of a larger project to characterize split HPWH performance, we evaluated the feasibility of installing an additional, parallel tank that could provide hot water to a second housing unit using a single CO2 heat pump. This approach would reduce the first costs of these more expensive units. Based on the high draw volume that we imposed on both tanks, the same heat pump may be able to support more tanks, depending on hot water usage. This paper will describe the split CO2 HPWH technology, how the two-tank system was controlled, and results from our laboratory evaluation.

CO2 HPWH↗

Linking microstructure to creep behavior in vertically and horizontally built LPBF Haynes 282 compared with wrought material via θ -projection

Laser Powder Bed Fusion (LPBF) has emerged as a promising route for fabricating intricate geometries in high-performance alloys. Haynes 282 (H282) is a strong candidate for applications such as heat exchangers or engines due to its excellent creep strength and thermal stability; however, the long-term creep behavior of LPBF-processed H282 remains poorly understood. In this study, the θ -projection method is used to analyze and extrapolate the creep behavior of vertically built LPBF, horizontally built LPBF, compared to wrought H282 tested at 816 °C. Vertically built LPBF H282 exhibits the lowest minimum creep rate (MCR), while the horizontally built condition shows a higher MCR comparable to that of wrought H282. Despite these differences, both LPBF conditions exhibit significantly shorter rupture life and reduced rupture strain than the wrought material, with the most severe degradation observed in the horizontal builds, consistent with an earlier onset of tertiary creep and accelerated strain-rate evolution. Microstructural characterization reveals that both LPBF and wrought H282 exhibit abundant twin-related boundary character; however, their grain boundary topologies differ markedly. The wrought alloy contains a higher fraction of low-angle grain boundaries and continuous twin lamellae, whereas the LPBF microstructure is characterized by a suppressed low-angle boundary population and fragmented twin-related boundaries embedded within irregular high-angle grain boundary networks. Fractographic analysis further reveals predominantly intergranular cracking in LPBF H282, accompanied by grain-boundary-decorated carbides, Al 2 O 3 inclusions, and high-aspect-ratio pores. These results demonstrate that grain boundary topology, rather than minimum creep rate alone, plays a critical role in governing creep damage accumulation and rupture behavior in LPBF and wrought H282.

Creep↗

High plasticity in refractory composite fabrication by ultrasonic additive manufacturing

Refractory metal composites are desirable for use in extreme environments that require materials with high specific strengths and resilience to external environments such as that found in nuclear and aerospace. However, due to the high melting temperature of refractories, liquid state joining processes such as welding remains difficult. Ultrasonic additive manufacturing (UAM) provides a potential route for processing refractory composites because it is a solid-state (i.e., no-melting) process and allows for intermittent machining operations to be performed between welds. Further, to demonstrate refractory composite fabrication, this study utilized UAM to machine a cavity to locate and sequester a Mo foil in a Zircaloy-4 (Zry-4) baseplate and additively build over the top with Zry-4 foils, thereby embedding the Mo in Zry-4 matrix. Significant deformation of the Zry-4 microstructure was observed: this deformation caused adiabatic heating and subsequent dynamic recrystallization through the transformation from α→β and then back to α as the material cooled. Flexural testing of the Zr–Mo composite revealed no delamination or failure, but the strength was not as expected, falling lower than a cold-worked Zry-4 sample. Finite element analysis supported that some bonding must have existed between the Zry-4 and Mo. There was indeed an interdiffusion zone at the Zry-4 foil–Mo foil interface, observing a metastable body-centered cubic β-Zr lathe. It was determined that sufficient strain energy was present to encourage the nucleation of the β-Zr grain along α-Zr grains. Future work is warranted to investigate UAM for refractory composite fabrication.

36 MATERIALS SCIENCE↗

Potential energy savings benefits and limitations of radiative cooling coatings for U.S. residential buildings

We report radiative coatings are a promising strategy to implement passive cooling that provides an eco-friendly pathway to achieve energy efficiency in buildings. This study investigates the benefits and limitations of implementing radiative coatings on the building envelope, particularly the roof, of residential buildings in the United States. The analysis compares the performance of an ideal radiative coating with broadband surface properties to a realistic radiative coating with diffuse and semitransparent properties. To enhance the net energy efficiency of buildings, we carried out a comprehensive parametric analysis comprising key radiation surface properties to maximize cooling energy savings while minimizing heating energy penalties. A countrywide assessment for 68 locations across the United States showed that net energy savings are a strong function of the climatic and atmospheric conditions. Broadly, southern locations showed high overall energy savings whereas northern locations exhibited high overall energy penalties. Locations in International Energy Conservation Code (IECC) climate zones 1A, 2A, and 2B showed a net annual energy savings above 5%, whereas locations in IECC climate zones 5B, 6B, and 7 showed a net annual energy penalty greater than 3%. The hot and dry climate of Phoenix, Arizona, showed the highest overall energy savings of 426 kWh (6.2%). Additionally, the mathematical correlation reveals that the net energy savings of a location is positive only when its average cooling degree days is greater than 5.5 or its average heating degree days is less than 10.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

RANGE: A robust adaptive nature-inspired global explorer of potential energy surfaces

With the growing demand for realistic representations of chemical structures and the advent of exascale computing, the intelligent sampling of potential energy surfaces and efficient identification of global minima have become more essential but also more feasible. Building on prior studies demonstrating the efficiency of the Artificial Bee Colony (ABC) swarm intelligence algorithm, we report a hybrid metaheuristic framework that integrates the adaptive exploration capabilities of ABC coupled with the exploitation strengths of genetic algorithms (GA) in a scalable, Python-based implementation. The resulting tool, RANGE (Robust Adaptive Nature-inspired Global Explorer), provides seamless interfaces to multiple potential energy evaluators, either directly or via widely used Python libraries, and is designed for high-performance computing environments. We describe the implementation details of RANGE and evaluate its performance, relative to ABC- or GA-alone based algorithms, on a variety of chemical systems, including molecular clusters and heterogeneous surfaces. In conclusion, our results demonstrate RANGE’s efficiency, robustness, and broad applicability in addressing challenging global optimization problems in computational chemistry and materials science.

Algorithms and data structure↗

Understanding Quantum Control Processor Capabilities and Limitations through Circuit Characterization

Continuing the scaling of quantum computers hinges on building classical control hardware pipelines that are scalable, extensible, and provide real time response. The instruction set architecture (ISA) of the control processor provides functional abstractions that map high-level semantics of quantum programming languages to low-level pulse generation by hardware. Here, we provide a methodology to quantitatively assess the effectiveness of the ISA to encode quantum circuits for intermediate-scale quantum devices with O(10 2 ) qubits. The characterization model that we define reflects performance, the ability to meet timing constraint implications, scalability for future quantum chips, and other important considerations making them useful guides for future designs. Using our methodology, we propose scalar (QUASAR) and vector (qV) quantum ISAs as extensions and compare them with other ISAs in metrics such as circuit encoding efficiency, the ability to meet real-time gate cycle requirements of quantum chips, and the ability to scale to more qubits.

97 MATHEMATICS AND COMPUTING↗

Scoping Study of Integrated Geothermal CO 2 Heat Pump and Water Well System in Cold Climate Region

This study evaluates the feasibility of using ground-source heat pumps (GSHPs) integrated with water wells for residential heating demands in cold regions of the United States. Four different heat pump systems were evaluated and compared: a CO 2 air-source heat pump (ASHP), a R-410A ASHP, a CO 2 GSHP integrated with well water, and a R-410A GSHP integrated with well water. Simulations were conducted at both equipment and building integration levels, followed by a nationwide analysis across 10 selected cities. Results indicate that integrating GSHP technology with existing water wells (e.g., artesian, bedrock, drilled, and collector wells) is a feasible heating solution because of their high flow rates, good water quality, stable temperatures, and low environmental impact. Although R-410A systems demonstrate higher efficiency, CO 2 systems are more suitable for heating from contamination-free and energy security perspective. The CO 2 GSHPs maintain better performance in colder climates compared with that of ASHPs, providing higher coefficient of performance and environmental benefits because CO 2 refrigerant leakage would not contaminate well water. A national analysis confirms that CO 2 GSHPs outperform furnaces, especially in cold climates, making them a promising solution for residential heating.

99 GENERAL AND MISCELLANEOUS↗

Scoping Study of Integrated Geothermal CO 2 Heat Pump and Water Well System in Cold Climate Region (CRADA Final Report)

This study evaluates the feasibility of using ground-source heat pumps (GSHPs) integrated with water wells for residential heating demands in cold regions of the United States. Four different heat pump systems were evaluated and compared: a CO 2 air-source heat pump (ASHP), a R-410A ASHP, a CO 2 GSHP integrated with well water, and a R-410A GSHP integrated with well water. Simulations were conducted at both equipment and building integration levels, followed by a nationwide analysis across 10 selected cities. Results indicate that integrating GSHP technology with existing water wells (e.g., artesian, bedrock, drilled, and collector wells) is a feasible heating solution because of their high flow rates, good water quality, stable temperatures, and low environmental impact. Although R-410A systems demonstrate higher efficiency, CO 2 systems are more suitable for heating from contamination-free and energy security perspective. The CO 2 GSHPs maintain better performance in colder climates compared with that of ASHPs, providing higher coefficient of performance and environmental benefits because CO 2 refrigerant leakage would not contaminate well water. A national analysis confirms that CO 2 GSHPs outperform furnaces, especially in cold climates, making them a promising solution for residential heating.

15 GEOTHERMAL ENERGY↗

Balancing Science Objectives and Operational Constraints: A Mission Planner's Challenge

The Air Force minute sensor technology integration (MSTI-3) satellite's primary mission is to characterize Earth's atmospheric background clutter. MSTI-3 will use three cameras for data collection, a mid-wave infrared imager, a short wave infrared imager, and a visible imaging spectrometer. Mission science objectives call for the collection of over 2 million images within the one year mission life. In addition, operational constraints limit camera usage to four operations of twenty minutes per day, with no more than 10,000 data and calibrating images collected per day. To balance the operational constraints and science objectives, the mission planning team has designed a planning process to e event schedules and sensor operation timelines. Each set of constraints, including spacecraft performance capabilities, the camera filters, the geographical regions, and the spacecraft-Sun-Earth geometries of interest, and remote tracking station deconflictions has been accounted for in this methodology. To aid in this process, the mission planning team is building a series of tools from commercial off-the-shelf software. These include the mission manifest which builds a daily schedule of events, and the MSTI Scene Simulator which helps build geometrically correct scans. These tools provide an efficient, responsive, and highly flexible architecture that maximizes data collection while minimizing mission planning time.

Weldy, Michelle↗

Defining Tolerance: Impacts of Delay and Disruption when Managing Challenged Networks

Challenged networks exhibit irregularities in their communication performance stemming from node mobility, power constraints, and impacts from the operating environment. These irregularities manifest as high signal propagation delay and frequent link disruption. Understanding those limits of link disruption and propagation delay beyond which core networking features fail is an ongoing area of research. Various wireless networking communities propose tools and techniques that address these phenomena. Emerging standardization activities within the Internet Research Task Force (IRTF) and the Consultative Committee for Space Data Systems (CCSDS) look to build upon both this experience and scalability analysis. Successful research in this area is predicated upon identifying enablers for common communication functions (notably node discovery, duplex communication, state caching, and link negotiation) and how increased disruptions and delays affect their feasibility within the network. Networks that make fewer assumptions relating to these enablers provide more universal service. Specifically, reliance on node discovery and link negotiation results in network-specific operational concepts rather than scalable technical solutions. Fundamental to this debate are the definitions, assumptions, operational concepts, and anticipated scaling of these networks. This paper presents the commonalities and differences between delay and disruption tolerance, including support protocols and critical enablers. We present where and how these tolerances differ. We propose a set of use cases that must be accommodated by any standardized delay-tolerant network and discuss the implication of these on existing tool development.

mobility drivers↗

Data-Driven State of Health Estimation for Second-Life Batteries Using Interpolated Synthetic Data and Feature Selection

Accurate estimation of the State of Health (SOH) for second-life batteries (SLBs) is crucial given their increasing use in energy storage applications. Precise SOH prediction is essential for safe operation and robust battery management systems. A major challenge is the limited availability of datasets for building reliable degradation models. To address this, synthetic data generation through linear interpolation is performed to extend the available data, making it more representative of real-world battery operating conditions. By analyzing feature correlation with SOH, the most relevant features are selected for the model. The proposed approach employs a convolutional neural network (CNN) model trained on this interpolated, feature-selected dataset, using time series data of voltage, temperature, and current over a cycle. By focusing on highly correlated features, the model achieves over 95% accuracy, with mean absolute error and root mean squared error up to 2.27% and 2.64%, respectively, in SOH estimation for two battery datasets tested. These results highlight the potential of combining synthetic data generation and feature selection to enhance SOH predictions, showcasing the superior performance of the proposed CNN model for both new batteries and SLBs.

feature selection↗

NASA Glenn Research Center Support of the Advanced Stirling Radioisotope Generator Project

A high-efficiency radioisotope power system was being developed for long-duration NASA space science missions. The U.S. Department of Energy (DOE) managed a flight contract with Lockheed Martin Space Systems Company to build Advanced Stirling Radioisotope Generators (ASRGs), with support from NASA Glenn Research Center. DOE initiated termination of that contract in late 2013, primarily due to budget constraints. Sunpower, Inc., held two parallel contracts to produce Advanced Stirling Convertors (ASCs), one with Lockheed Martin to produce ASC-F flight units, and one with Glenn for the production of ASC-E3 engineering unit "pathfinders" that are built to the flight design. In support of those contracts, Glenn provided testing, materials expertise, Government-furnished equipment, inspection capabilities, and related data products to Lockheed Martin and Sunpower. The technical support included material evaluations, component tests, convertor characterization, and technology transfer. Material evaluations and component tests were performed on various ASC components in order to assess potential life-limiting mechanisms and provide data for reliability models. Convertor level tests were conducted to characterize performance under operating conditions that are representative of various mission conditions. Despite termination of the ASRG flight development contract, NASA continues to recognize the importance of high-efficiency ASC power conversion for Radioisotope Power Systems (RPS) and continues investment in the technology, including the continuation of the ASC-E3 contract. This paper describes key Government support for the ASRG project and future tests to be used to provide data for ongoing reliability assessments.

Technology Transfer↗

Modeling the impact of structure and coverage on the reactivity of realistic heterogeneous catalysts

Adsorbates often cover the surfaces of catalysts densely as they carry out reactions, dynamically altering their structure and reactivity. Understanding adsorbate-induced phenomena and harnessing them in our broader quest for improved catalysts is a substantial challenge that is only beginning to be addressed. Here, in this work, we chart a path toward a deeper understanding of such phenomena by focusing on emerging in silico modeling methodologies, which will increasingly incorporate machine learning techniques. We first examine how adsorption on catalyst surfaces can lead to local and even global structural changes spanning entire nanoparticles, and how this affects their reactivity. We then evaluate current efforts and the remaining challenges in developing robust and predictive simulations for modeling such behavior. Last, we provide our perspectives in four critical areas—integration of artificial intelligence, building robust catalysis informatics infrastructure, synergism with experimental characterization, and adaptive modeling frameworks—that we believe can help surmount the remaining challenges in rationally designing catalysts in light of these complex phenomena.

catalytic mechanisms↗

Split HPWHs as an Efficient Solution for Multifamily Buildings with In-Unit Water Heaters: Preprint

A quarter of all housing units in the country are found in multifamily buildings but few efficiency innovations have been made to improve electric water heating systems in this building type. Domestic hot water in multifamily buildings can either be provided by a large central water heater or smaller in-unit water heaters. Integrated heat pump water heaters that are installed in single family homes are often a poor fit for individual multifamily units since the water heaters are often located in small internal closets. This confined space can limit the air flow to the heat pump and the cold exhaust air can cause discomfort and reduced efficiency. Split CO2 HPWHs separate the tank from the heat pump, which allows for installation location flexibility. Further, CO2 heat pumps can operate under colder ambient conditions, making them a better fit for multifamily units across a wide range of climate regions. As part of a larger project to characterize split HPWH performance, we evaluated the feasibility of installing an additional, parallel tank that could provide hot water to a second housing unit using a single CO2 heat pump. This approach would reduce the first costs of these more expensive units. Based on the high draw volume that we imposed on both tanks, the same heat pump may be able to support more tanks, depending on hot water usage. This paper will describe the split CO2 HPWH technology, how the two-tank system was controlled, and results from our laboratory evaluation.

CO2 HPWH↗

An Automatic Cloud Mask Algorithm Based on Time Series of MODIS Measurements

Quality of aerosol retrievals and atmospheric correction depends strongly on accuracy of the cloud mask (CM) algorithm. The heritage CM algorithms developed for AVHRR and MODIS use the latest sensor measurements of spectral reflectance and brightness temperature and perform processing at the pixel level. The algorithms are threshold-based and empirically tuned. They don't explicitly address the classical problem of cloud search, wherein the baseline clear-skies scene is defined for comparison. Here, we report on a new CM algorithm which explicitly builds and maintains a reference clear-skies image of the surface (refcm) using a time series of MODIS measurements. The new algorithm, developed as part of the Multi-Angle Implementation of Atmospheric Correction (MAIAC) algorithm for MODIS, relies on fact that clear-skies images of the same surface area have a common textural pattern, defined by the surface topography, boundaries of rivers and lakes, distribution of soils and vegetation etc. This pattern changes slowly given the daily rate of global Earth observations, whereas clouds introduce high-frequency random disturbances. Under clear skies, consecutive gridded images of the same surface area have a high covariance, whereas in presence of clouds covariance is usually low. This idea is central to initialization of refcm which is used to derive cloud mask in combination with spectral and brightness temperature tests. The refcm is continuously updated with the latest clear-skies MODIS measurements, thus adapting to seasonal and rapid surface changes. The algorithm is enhanced by an internal dynamic land-water-snow classification coupled with a surface change mask. An initial comparison shows that the new algorithm offers the potential to perform better than the MODIS MOD35 cloud mask in situations where the land surface is changing rapidly, and over Earth regions covered by snow and ice.

Lyapustin, Alexei↗

End-Use Savings Shapes Measure Documentation: Heat Pump Rooftop Units

The heat pump rooftop units (RTUs) measure replaces gas furnace and electric resistance RTUs with high-efficiency heat pump rooftop units (HP-RTUs). The HP-RTUs are intended to be top-of-the line, including high-efficiency fans and heat pump systems. The fans are variable speed, allowing the HP-RTUs to operate as single-zone variable air volume systems. The heat pumps are also variable speed, allowing for high part load performance. All schedules in the existing RTUs are transferred to the new HP-RTUs for consistency. Furthermore, any energy efficiency features in the existing baseline RTUs such as energy recovery or economizers are also transferred to the new HP-RTUs for consistency. This measure is applicable to approximately 45% of the ComStock floor area. The HP-RTU measure demonstrates 10.3% total site energy savings (449 trillion British thermal units [TBtu]) for the U.S. commercial building stock modeled in ComStock.