A comparison of estimated and directly measured turbulent heat fluxes in the lower stratosphere

The contribution of small-scale motions to the vertical heat flux in the lower stratosphere is determined from wind and temperature fluctuation statistics obtained during the High Altitude Clear Air Turbulence investigation. Analysis of the cospectra suggests a horizontal wavelength of 3 km as the appropriate long-wave cutoff of small-scale motion. With this scale restriction, the measured vertical heat fluxes are in good agreement with the values of heat flux estimated by Lilly et al. (1974) from the kinetic energy dissipation rate. Hence, the hypothesis of Lilly et al. for estimating heat flux from the dissipation rate is considered to be reliable. It follows that, in the lower stratosphere, subsynoptic vertical transport is small compared to large-scale transport.

Heck, W.↗

Search for Chemically Bound Water in the Surface Layer of Mars Based on HEND/Mars Odyssey Data

This study is emphasized on search for signatures of chemically bound water in surface layer of Mars based on data acquired by High Energy Neutron Detector (HEND) which is part of the Mars Odyssey Gamma Ray Spectrometer (GRS). Fluxes of epithermal (probe the upper 1-2 m) and fast (the upper 20-30 cm) neutrons, considered in this work, were measured since mid February till mid June 2002. First analysis of this data set with emphasis of chemically bound water was made. Early publications of the GRS results reported low neutron flux at high latitudes, interpreted as signature of ground water ice, and in two low latitude areas: Arabia and SW of Olympus Mons (SWOM), interpreted as 'geographic variations in the amount of chemically and/or physically bound H2O and or OH...'. It is clear that surface materials of Mars do contain chemically bound water, but its amounts are poorly known and its geographic distribution was not analyzed.

Basilevsky, A. T.↗

Peak pool boiling heat flux in viscous liquids

The stability of a gas jet in a surrounding viscous liquid is studied. An expression is developed for the critical velocity at which the jet becomes unstable in a returning viscous liquid. The stability analysis is made to correspond with the geometrical configuration of gas jets and liquid columns similar to those observed near the peak pool boiling heat flux. The critical velocity of the gas jet is then used to obtain the functional form of the peak heat flux on flat plates and cylindrical heaters. The expressions are compared with original observations of the peak heat flux in very viscous liquids on flat plate, and cylindrical, heaters at both earth-normal, and elevated, gravities.

Dhir, V. K.↗

Developing a Pyrolysis Gas Thermal Blocking Model for Reentry Demise

In NASA’s Object Reentry Survival Analysis Tool (ORSAT), aerodynamic drag and aerothermal heating coefficients are computed for each of the free-molecular, continuum, and transitional flow regimes using analytical and semi-analytical methods. These heating coefficients were derived for typical metallic materials that melt and do not have a strong gas-phase contribution to the flow in the boundary layer. Modern satellites typically feature fiber-reinforced polymer (FRP) components, such as solar array booms, facesheets of sandwich panels, or overwraps for composite-overwrapped pressure vessels (COPV). These FRP materials do not behave the same as metals in the reentry environment, but instead will pyrolyze and develop significant volumes of gas into the boundary layer. Accurately predicting the reentry demise of FRP components is critical to assessing the reentry casualty risk for modern spacecraft. Research in recent years has shown that this demisability can depend heavily on how the expulsion of gaseous pyrolysis products through the outer surface of the material affects the heat flux at the surface. The ODPO has been developing a reduced-order model of the effect of pyrolysis gas blowing on the heat flux based on correlations between a blowing factor and a non-dimensional heat flux to be incorporated in the upcoming version 7.3 of the Object Reentry Survivability Analysis Tool (ORSAT). This presentation discusses the progress of this development project and the challenges remaining for generalizing the model across families of FRP materials.

Benton Greene↗

A title-gap flow model for use in aerodynamic loads assessment of space shuttle thermal protection system: Parallel gap faces

The problem of predicting aerodynamic loads on the insulating tiles of the space shuttle thermal protection system (TPS) is discussed and seen to require a method for predicting pressure and mass flux in the gaps between tiles. A mathematical model of the tile-gap flow is developed, based upon a slow viscous (Stokes) flow analysis, and is verified against experimental data. The tile-gap pressure field is derived from a solution of the two-dimensional Laplace equation; the mass-flux vector is then calculated from the pressure gradient. The means for incorporating this model into a lumped-parameter network analogy for porous-media flow is given. The means for incorporating this model into a lumped-parameter network analogy for porous-media flow is given. The flow model shows tile-gap mass flux to be very sensitive to the gap width indicating a need for coupling the TPS flow and tile displacement calculation. Analytical and experimental work to improve TPS flow predictions and a possible shuttle TPS hardware modification are recommended.

Dwoyer, D. L.↗

Search for lightning-induced electron precipitation with rocket-borne photometers

Photometers at 3914 A and 5577 A and an optical imager were part of an experimental package launched on a sounding rocket in the 1987 Wave Induced Particle Precipitation campaign at Wallops Island, Virginia. The objective was to measure lightning-induced electron precipitation (LEP) by means of its optical signature. This was the first attempt to measure LEP using rocket-borne optical instrumentation. Launch criteria included nearby thunderstorm activity and ground-based observations of Trimpi events. Lightning flashes are clearly discernible in the data. The photometer data was also characterized by large spin and precession modulations in the photon count rate, consistent with elevated steady particle fluxes in the northern portion of the instrument field of view. No evidence of LEP was observed by the photometers or onboard particle detectors (Arnoldy and Kintner, 1989). Analysis of the data has made it possible to place an upper limit of 0.0008 ergs/sq cm per sec on any burst precipitation energy flux that may have occurred during the rocket flight in the regions explored by the photometers.

Massey, R. D.↗

ANS Winter 2022: ATF-2C Physics Safety and Scoping Analysis

ATF-2C comprises four tiers with six rodlets each. The experiment test train (TT) is situated in Loop 2A in the center flux trap (CFT) of the ATR, in which typical pressurized water reactor (PWR) conditions shall be approximated. Tier 1 (bottom) of the TT tests Framatome silicon carbide (SiC) cladding, containing molybdenum heater rods. Low-enriched uranium (LEU) Framatome rodlets with chrome-coated M5 cladding have been modeled in their place for the physics safety analysis to allow the substitution of this tier with fuel if needed. Tier 2 tests LEU Framatome rodlets with M5 cladding, which had irradiated in ATR in prior ATF experiments. Tier 3 tests General Atomics SiC composite cladding, also containing molybdenum heater rods. Tier 4/5/6 (top) tests the Japan Atomic Energy Agency (JAEA)/Mitsubishi Heavy Industries (MHI) fueled rodlets. This upper tier tests LEU rodlets with chrome-coated MDA cladding—several with temperature or pressure instrumentation. To flatten the axial power profile, lower portion of Tier 4/5/6 is surrounded by a hafnium (Hf) shroud, and the bottom two UO2 pellets are of natural enrichment. The ATF-2C TT is to be irradiated in the CFT of ATR (Fig. 1) for three or four 60-day cycles.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Behavior of Triple Langmuir Probes in Non-Equilibrium Plasmas

A model of current collection in Langmuir probes is used to investigate the effect representative non- equilibrium plasmas under various conditions have on the electron temperature and number density that would be calculated through analysis of the probe collection characteristics. The model uses the distribution function to calculate the charged particle flux to a probe and then, for fixed applied voltages, the current values that satisfy continuity in the probes are determined. The triple probe is not scanned in voltage, so there is no practical way using experimental triple probe data to determine if the plasma is in equilibrium. As a consequence, a triple probe analysis typically relies on the assumption that the plasma is in equilibrium. Proceeding from this point, the numerically-generated non-equilibrium triple probe data are analyzed assuming that the plasma is in equilibrium, with the data compared to the initial distribution function inputs of plasma temperature and number density to determine the effect the non-equilibrium distribution has on plasma measurements. The temperature and number density are both significantly affected when a fraction of the particles in the distribution are shifted from the equilibrium configuration into the non-equilibrium part of the distribution function. For all instances studied, the computed electron temperature and number density are extremely sensitive to small deviations from equilibrium ( ≤ 5% of the plasma shifted into the non-equilibrium function). Shifting more of the plasma into the non-equilibrium distribution beyond this initial level does not produce a significant additional shift in the computed plasma properties.

Polzin, Kurt A.↗

WIRE-21 Sensor Irradiation Experiment Ready for HFIR Insertion

The ability to deploy new nuclear fuels for current or future reactor concepts requires a wealth of data regarding fuel performance during normal operation, anticipated operational occurrences, and design-basis accidents. Most of these data have historically been collected during experiments in materials test reactors, ideally with online instrumentation to collect as much data as possible. However, advanced instrumentation could also allow for in situ monitoring of fuel operating conditions during commercial reactor operation to maximize fuel utilization, reduce unnecessary conservativism in design margins, and improve operator understanding of limiting peaking factors. The latter approach would complicate fuel handling, particularly during refueling, unless the instrumentation could be placed inside the fuel rods and transmitted wirelessly to a receiver located outside the fuel’s primary pressure boundary. To this end, Westinghouse Electric Company (WEC) developed wireless sensors based on inductive coupling that can transmit information regarding fuel centerline temperatures and rod internal pressures wirelessly from within a fuel rod to a nearby instrument thimble. After testing these sensors in lower-power university research reactors, the next step is to perform high neutron fluence testing to characterize the performance of these wireless sensors under conditions that are more representative of the intended application—in this case, light-water reactors (LWRs). The removable Be (RB) positions of the High Flux Isotope Reactor (HFIR) at Oak Ridge National Laboratory (ORNL) provide the neutron flux, experiment volume, and access to instrument leads required to achieve these sensor testing goals. This report summarizes the design, analysis, and assembly of the Wireless Instrumented RB Experiment 2021 (WIRE-21). This is the most highly instrumented irradiation experiment ever performed in HFIR. The experiment will use seven different sensing techniques to measure temperature, pressure, neutron flux, and neutron fluence during reactor operation. In addition to WEC’s wireless temperature and pressure sensors, WIRE-21 includes an array of thermocouples, self-powered neutron detectors, spatially distributed fiber optic temperature sensors, passive SiC temperature monitors, and flux wires. The design of WIRE-21 and the cabling that was installed in HFIR also provide the infrastructure to enable accelerated, economical testing of advanced sensor technologies while leveraging the extremely high neutron flux that is available in HFIR. The containment for WIRE-21 is similar to previous RB irradiation vehicles but includes a few modifications, most notably the use of integrated compression seals to pass a larger number of sensor leads through the experiment’s pressure boundary. In addition to the sensor leads, inert gas lines are passed into the experiment to enable active temperature control and the ability to pneumatically actuate a bellows-driven pressure sensor. WIRE-21 is targeting component temperatures (300–350°C) and neutron fluence levels (~10 22 n/cm 2 ) that would be expected in the plenum region of LWR fuels, except for the active sensing region of the wireless temperature sensor, which is targeting LWR fuel centerline temperatures (~800–1,100°C). WIRE-21 was successfully assembled, passed all nondestructive examination, and was delivered to HFIR for insertion during upcoming cycle 498 (April 2022).

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

RAPID UNSEPARATED RARE EARTH ELEMENT ANALYSES BY ISOTOPE DILUTION MULTICOLLECTOR INDUCTIVELY COUPLED MASS SPECTROMETRY (ID-MC-ICP-MS)

We present a method for analyzing rare earth elements (REEs) by isotope dilution without separation of individual elements. Utilizing a Nu Plasma 2 multicollector inductively coupled plasma mass spectrometer (MC-ICP-MS) equipped with an Aridus II desolvation nebulizer, sample introduction tuning parameters (torch position, gas flows) were investigated and used to minimize oxide formation (e.g., NdO/Nd <0.05%) and remove the need to analyze the REEs as separated “cuts.” Ratios for spike/sample isotopes in mixed synthetic standards containing varying amounts of Ce, Nd, Sm, Eu, Gd, Dy, Er, and Yb were measured accurately within 1% of IUPAC values. La and Lu in the standards were more than 2% off from expected values due to more demanding interference corrections. A USGS BCR-2 rock standard was also processed with flux fusion, iron coprecipitation and a single column pass bulk separation followed by analysis. The concentrations for Ce, Nd, Sm, Eu, Dy, Er, and Yb fell within 2% of consensus values. A United States Geological Survey (USGS) BIR-1A rock standard was also processed in triplicate by hydrofluoric and nitric acid digestion, yielding rare earth concentrations within 3% of consensus values with 0.3% relative standard deviation (n=3). This demonstrates the ability to produce high quality REE patterns of comparable quality to traditional methods involving labor and time intensive REE separation, with sample preparation and analytical times that are comparable to analyses against isotope dilution by single-collector ICP-MS.

Shen, Steve D.↗

Anthropogenic sulfate aerosol pollution in South and East Asia induces increased summer precipitation over arid Central Asia

Precipitation has increased across the arid Central Asia region over recent decades. However, the underlying mechanisms of this trend are poorly understood. Here, we analyze multi-model simulations from the Precipitation Driver and Response Model Intercomparison Project (PDRMIP) to investigate potential drivers of the observed precipitation trend. We find that anthropogenic sulfate aerosols over remote polluted regions in South and East Asia lead to increased summer precipitation, especially convective and extreme precipitation, in arid Central Asia. Elevated concentrations of sulfate aerosols over remote polluted Asia cause an equatorward shift of the Asian Westerly Jet Stream through a fast response to cooling of the local atmosphere at mid-latitudes. This shift favours moisture supply from low-latitudes and moisture flux convergence over arid Central Asia, which is confirmed by a moisture budget analysis. High levels of absorbing black carbon lead to opposing changes in the Asian Westerly Jet Stream and reduced local precipitation, which can mask the impact of sulfate aerosols. This teleconnection between arid Central Asia precipitation and anthropogenic aerosols in remote Asian polluted regions highlights long-range impacts of anthropogenic aerosols on atmospheric circulations and the hydrological cycle.

54 ENVIRONMENTAL SCIENCES↗

Impact of Radial Reflector Fidelity on Neutronics and Vessel Fluence Simulations

The Consortium for Advanced Simulation of Light Water Reactors is developing the Virtual Environment for Reactor Applications (VERA), and the MPACT code, which is the primary deterministic neutron transport solver in VERA, provides sub-pin level flux and power distributions as part of full-scale cycle depletion and analysis. In such calculations, an important aspect is the radial reflector treatment. To improve the fidelity of the radial reflector treatment, MPACT was extended to approximate the modeling of the reactor’s structural components such as the core shroud, barrel, neutron pads, and vessel. This work explores several modeling configurations with varying levels of fidelity and computational burden and assesses the importance of modeling fidelity on the eigenvalue and pin power distribution. Two two-dimensional (2-D) problems were analyzed to assess the impact on eigenvalue and pin power distributions with low-fidelity, coarse square cell reflector representations: (1) a Watts Bar Nuclear Plant Unit 1 (WBN1) quarter-core slice with depletion and (2) an AP1000 quarter-core slice. In this work, the analyses showed that the effect on eigenvalue is fairly small, but the effect on pin power is more pronounced, especially locally in the assemblies closest to the periphery, where the maximum pin power difference is nearly 3.5% in the AP1000 case. Two additional 2-D problems were used to assess the comparison between the low-fidelity coarse square cell treatment and a high-fidelity geometric representation that uses subpin material specification: (1) the same WBN1 quarter-core slice and (2) a representative model of the NuScale small modular reactor (SMR), which features a solid reflector design with moderator holes. These results demonstrate that even a coarse, low-fidelity representation adequately captures the necessary simulation characteristics. Last, these capabilities were applied to the 2-D WBN1 quarter-core depletion to assess the impact on vessel fluence using VeraShift. From adjoint calculations, pins along the periphery were observed to be of highest importance for fluence calculation, so the impact of the reflector representation in MPACT could theoretically substantially affect the predicted result. However, it was observed that the change in pin powers along the periphery minimally impacts the maximum vessel fluence with a difference within the statistical uncertainty but provides terrific insight on the sensitivity of the peripheral pins.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Accuracy of HVAC Load Predictions: Validation of EnergyPlus and DOE-2 using FLEXLAB Measurements

The aim of the project reported here was to better understand the level of accuracy of three building energy simulation (BES) engines (‘engines’) — EnergyPlus™, DOE-2.1e, and DOE-2.2 — by identifying and investigating significant deviations between the performance predicted by these engines and actual performance as measured in the FLEXLAB® test facility at Lawrence Berkeley National Laboratory (LBNL). The specific test conditions included some of those prescribed in ANSI/ASHRAE Standard 140 - Standard Method of Test for the Evaluation of Building Energy Analysis Computer Programs. Detailed measurements of FLEXLAB performance, including indoor temperatures and heat fluxes and air-flow and water flow rates and temperatures in the Heating, Ventilating and Air Conditioning (HVAC) system, together with hourly weather data, were recorded and used in analyzing the simulation results from EnergyPlus v8.8, DOE-2.2 v3.65 and DOE-2.1e v127. These engines are commonly used in the United States for building energy code compliance, federal, state, and utility incentives programs, as well as energy efficient design of new buildings and energy retrofit of existing buildings. Seven conventional overhead mixing ventilation scenarios were tested and each engine was found to have a similar level of agreement with the measurements of space-level heating and sensible cooling loads. These results provide useful information regarding the accuracy of these engines in predicting the cooling and heating load elements of whole building energy performance. This information is intended for practitioners who are concerned about transitioning between simulation tools with different engines and for managers of utility programs leveraging these tools for evaluating and/or projecting measure savings to be incentivized under their programs. The results of the comparisons of simulated and measured performance indicate that the predictions from all three engines are not significantly different. The 24-hour average value of the absolute mean bias indicates the likely magnitude of the error in any particular case. The average mean bias is reduced by cancelation of overprediction in one case by underprediction in another. The daytime absolute mean biases, which may be more important for both energy performance and occupant comfort, are ~6%, presumably because of the greater complexity involved in simulating in the presence of solar radiation. EnergyPlus typically overpredicts the cooling load and/or underpredicts the heating load by ~1.5% and the DOE-2 engines typically underpredict the cooling load by approximately the same amount. The Root Mean Square Error is relatively more sensitive to shorter term variations in the difference between predicted and measured loads; the three engines have similar values, ~10%, suggesting that the uncertainties in their predictions of peak loads may also be similar in magnitude. The implication of these results is that users, both designers and program analysts, can use EnergyPlus, DOE-2.1e, or DOE-2.2 to model conventional commercial buildings equipped with overhead mixing ventilation with a similar level of confidence. Further work is required to better understand the variability in the level of agreement between the engine predictions and FLEXLAB measurements, where a particular engine will agree well with FLEXLAB in some cases and not so well in others and another engine will agree or disagree in different cases. As the sources of this variability are identified and eliminated or reduced significantly, it is recommended that the experimental capabilities and methods developed in the study reported here should be applied to validating heating and cooling load calculations for spaces with different types of furniture and miscellaneous loads. These methods should then be applied to low energy space conditioning systems in EnergyPlus including, in particular, radiant slab and radiant ceiling panel cooling and heating systems and ‘mixed mode’ systems that combine mechanical cooling and natural ventilation systems, focusing on controls, including control of thermal mass. The work reported here addresses the conventional method of heating and cooling occupied spaces; other methods, such as the use of radiant heating and cooling systems have the potential to provide equivalent occupant comfort, or better, with lower energy consumption. These systems are addressed more explicitly in EnergyPlus but there is a need for empirical validation to give users the same level of confidence in modeling these systems that they have, or should have, in modeling conventional systems, based on the results presented here.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Search for muon neutrino disappearance with multi-topologically splitted Inclusive events at SBN

The Short-Baseline Neutrino (SBN) program at Fermilab searches for signatures of sterile neutrinos with mass-squared splittings at the O(1) eV2 scale, motivated by anomalies previously reported by the LSND and MiniBooNE experiments. We present a search for such signatures using the muon neutrino disappearance channel. This analysis exploits the large statistics of fully inclusive charged-current interactions collected by the SBND and ICARUS detectors to maximize sensitivity. The inclusive samples in both detectors are further subdivided into multiple exclusive topological channels, a strategy designed to enhance sensitivity by isolating differences in interaction-mode composition and reconstructed energy response. This multi-topology approach represents a novel analysis technique within SBN, enabling improved constraints on systematic uncertainties arising from neutrino flux, interaction modeling, and detector response. We will present comparisons of data with detailed predictions incorporating a comprehensive treatment of systematic uncertainties and constraints on the systematics obtained by the multi-topology method.

Yadav, Shweta [Texas U., Arlington]↗

The electron heating rate and ion chemistry in the thermosphere above Wallops Island during the solar eclipse of 7 March 1970.

Measurement of the N2 concentration and temperature, the ion composition and concentrations, and the electron temperature up to 290 km about 30 and 5 min before totality during the Mar. 7, 1970, eclipse. The rockets traveled similar trajectories, thus permitting the purely temporal changes between flights to be resolved. The neutral temperature and N2 concentration changed little, but the electron temperature decreased by as much as 20% in the lower F region. The ion concentration decreased by about 30% in the F region and about 50% in the E region, with little change in relative ion composition. The electron cooling rates decreased by a factor of 6 in the lower F region, approximately in proportion to the change in the visible solar disk. A smaller than expected decrease in the cooling rate below 150 km between the two flights indicates a hardening of the solar spectrum and suggests a significant heat contribution from the solar corona near totality. The ion composition measurements were consistent with solutions of the ion continuity equations. A proper fit required a factor-of-three enhancement of the flux below 200 A, an amount also consistent with the electron heat balance analysis. Reactions involving the minor ions N(+) and N2(+) were found to be important for the ion chemistry of the major ions O2(+) and NO(+), especially at the time of eclipse.-

Brace, L. H.↗

Intensity Oscillation of Low Energy Solar Particles Observed on the IMP 7 Satellite

Solar flare particles in the energy range from 125 to 160 KeV per charge were detected and analyzed by an electrostatic deflection vs. energy instrument on board the Explorer 47 (IMP 7) satellite. A harmonic analysis of the counting rates shows that frequently, the fluctuation of the particle flux can be approximately represented by N(t) = f(t)sin 2 pi nu t where f(t) is a smoothly varying function of t. The oscillation frequency nu varies from flare to flare and is of the order of 2 x .001/sec. The physical implications of the finding are discussed.

Fan, C. Y.↗

A test of the comet hypothesis of the Tunguska Meteor Fall - Nature of the meteor 'thermal' explosion paradox

The hypothesis that a comet was responsible for the Tunguska Meteor Fall is rejected because the hypothesis does not seem to account for the intense terminal spherical shock. A porous meteoroid model is proposed, and an analysis indicates that an entity of this type might produce an aerodynamic heat flux large enough to account for the terminal meteor explosion. It is suggested that the presence of olivine and of highly irregular macrostructure in meteors might indicate the presence of some porosity. For a highly porous meteoroid, it is postulated that during entry into the atmosphere the aerodynamic heat transfer at its external or pore walls would become so intensified as to cause either complete ablation with popping or a solid-liquid-vapor phase transition accompanied by an explosion.

Liu, V. C.↗