Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “fault detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,351 records · Page 75

A hardware-in-the-loop (HIL) testbed for cyber-physical energy systems in smart commercial buildings

In recent years, there has been a growing trend toward the development of smart buildings that rely on cyber-physical systems (CPS) to optimize occupant comfort, safety, and energy efficiency. To ensure the reliable and efficient operation of CPS with designed control strategies, it is important to evaluate their performance under various scenarios before deploying them in the real world. This is where a Hardware-in-the-loop (HIL) testbed designed for studying sensor and control-related studies in smart buildings can be highly valuable. With the growing threat of cyber-attacks and physical faults targeting smart buildings, it is essential to ensure the security of building operations. A HIL testbed can emulate cyber-attack and physical fault scenarios, allowing researchers to develop and test threat detection and mitigation algorithms. This enables researchers to identify potential issues and optimize the algorithms in a safe and controlled environment before they are deployed in real-world settings, reducing the risk of failures that can negatively impact occupant comfort, safety, and energy efficiency. Therefore, this paper developed a HIL testbed designed for cyber-physical energy systems (e.g. buildings automation system (BAS)) in smart commercial buildings. The HIL testbed is comprised of a real-time building and Heating, Ventilation, and Air-Conditioning (HVAC) emulator using Modelica-based dynamic models, a set of BAS controllers, and a BAS computer server. The data generation capability of the HIL testbed is demonstrated by tracking normal and faulty operating data in the BAS, as well as monitoring detailed network traffic in the local BAS network. Here, this study further demonstrates the HIL testbed’s capability by conducting case studies on real-time physical fault and cyber-attack experiments using a Department of Energy (DOE) prototype commercial building. It is anticipated that the fully functional HIL testbed will be utilized for a variety of sensor and control-related studies, including but not limited to testing, developing, validating of different HVAC control strategies, fault detection & diagnosis, energy monitoring and analysis, cyber security study, etc.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Onboard Nonlinear Engine Sensor and Component Fault Diagnosis and Isolation Scheme

A method detects and isolates in-flight sensor, actuator, and component faults for advanced propulsion systems. In sharp contrast to many conventional methods, which deal with either sensor fault or component fault, but not both, this method considers sensor fault, actuator fault, and component fault under one systemic and unified framework. The proposed solution consists of two main components: a bank of real-time, nonlinear adaptive fault diagnostic estimators for residual generation, and a residual evaluation module that includes adaptive thresholds and a Transferable Belief Model (TBM)-based residual evaluation scheme. By employing a nonlinear adaptive learning architecture, the developed approach is capable of directly dealing with nonlinear engine models and nonlinear faults without the need of linearization. Software modules have been developed and evaluated with the NASA C-MAPSS engine model. Several typical engine-fault modes, including a subset of sensor/actuator/components faults, were tested with a mild transient operation scenario. The simulation results demonstrated that the algorithm was able to successfully detect and isolate all simulated faults as long as the fault magnitudes were larger than the minimum detectable/isolable sizes, and no misdiagnosis occurred

Tang, Liang↗

Water quality monitor

The preprototype water quality monitor (WQM) subsystem was designed based on a breadboard monitor for pH, specific conductance, and total organic carbon (TOC). The breadboard equipment demonstrated the feasibility of continuous on-line analysis of potable water for a spacecraft. The WQM subsystem incorporated these breadboard features and, in addition, measures ammonia and includes a failure detection system. The sample, reagent, and standard solutions are delivered to the WQM sensing manifold where chemical operations and measurements are performed using flow through sensors for conductance, pH, TOC, and NH3. Fault monitoring flow detection is also accomplished in this manifold assembly. The WQM is designed to operate automatically using a hardwired electronic controller. In addition, automatic shutdown is incorporated which is keyed to four flow sensors strategically located within the fluid system.

West, S.↗

Instrumentation System Diagnoses a Thermocouple

An improved self-validating thermocouple (SVT) instrumentation system not only acquires readings from a thermocouple but is also capable of detecting deterioration and a variety of discrete faults in the thermocouple and its lead wires. Prime examples of detectable discrete faults and deterioration include open- and short-circuit conditions and debonding of the thermocouple junction from the object, the temperature of which one seeks to measure. Debonding is the most common cause of errors in thermocouple measurements, but most prior SVT instrumentation systems have not been capable of detecting debonding. The improved SVT instrumentation system includes power circuitry, a cold-junction compensator, signal-conditioning circuitry, pulse-width-modulation (PWM) thermocouple-excitation circuitry, an analog-to-digital converter (ADC), a digital data processor, and a universal serial bus (USB) interface. The system can operate in any of the following three modes: temperature measurement, thermocouple validation, and bonding/debonding detection. The software running in the processor includes components that implement statistical algorithms to evaluate the state of the thermocouple and the instrumentation system. When the power is first turned on, the user can elect to start a diagnosis/ monitoring sequence, in which the PWM is used to estimate the characteristic times corresponding to the correct configuration. The user also has the option of using previous diagnostic values, which are stored in an electrically erasable, programmable read-only memory so that they are available every time the power is turned on.

Perotti, Jose↗

Validation of Helicopter Gear Condition Indicators Using Seeded Fault Tests

A "seeded fault test" in support of a rotorcraft condition based maintenance program (CBM), is an experiment in which a component is tested with a known fault while health monitoring data is collected. These tests are performed at operating conditions comparable to operating conditions the component would be exposed to while installed on the aircraft. Performance of seeded fault tests is one method used to provide evidence that a Health Usage Monitoring System (HUMS) can replace current maintenance practices required for aircraft airworthiness. Actual in-service experience of the HUMS detecting a component fault is another validation method. This paper will discuss a hybrid validation approach that combines in service-data with seeded fault tests. For this approach, existing in-service HUMS flight data from a naturally occurring component fault will be used to define a component seeded fault test. An example, using spiral bevel gears as the targeted component, will be presented. Since the U.S. Army has begun to develop standards for using seeded fault tests for HUMS validation, the hybrid approach will be mapped to the steps defined within their Aeronautical Design Standard Handbook for CBM. This paper will step through their defined processes, and identify additional steps that may be required when using component test rig fault tests to demonstrate helicopter CI performance. The discussion within this paper will provide the reader with a better appreciation for the challenges faced when defining a seeded fault test for HUMS validation.

Dempsey, Paula↗

Characterizing the Impact of Soft Errors Affecting Floating-point ALUs using RTL-level Fault Injection

Strategies to detect, correct, or mitigate the impact of soft errors rely on errors-injection experiments. For efficient evaluation, such experiments typically inject errors in software by sampling errors from a candidate distribution. Most often, these strategies randomly select and flip one bit in the output of an instruction. While single-bit flips might constitute a meaningful model for errors affecting hardware, the appropriateness of this model for software-based errors has not been studied. In this paper, we study the manifestation of errors in the output registers due to errors affecting candidate instructions executed by floating point ALUs. We inject single-bit flips into the RTL descriptions of floating point ALUs and analyze the differences between anticipated and observed outputs when executing floating-point addition, subtraction, multiplication, and division. We choose the operands for these instructions randomly and from operands observed in five benchmarks. We observe a rich distribution of errors in the output and analyze their implications for software-based fault-injection campaigns.

Subasi, Omer↗

Using Decision Trees to Detect and Isolate Simulated Leaks in the J-2X Rocket Engine

The goal of this work was to use data-driven methods to automatically detect and isolate faults in the J-2X rocket engine. It was decided to use decision trees, since they tend to be easier to interpret than other data-driven methods. The decision tree algorithm automatically "learns" a decision tree by performing a search through the space of possible decision trees to find one that fits the training data. The particular decision tree algorithm used is known as C4.5. Simulated J-2X data from a high-fidelity simulator developed at Pratt & Whitney Rocketdyne and known as the Detailed Real-Time Model (DRTM) was used to "train" and test the decision tree. Fifty-six DRTM simulations were performed for this purpose, with different leak sizes, different leak locations, and different times of leak onset. To make the simulations as realistic as possible, they included simulated sensor noise, and included a gradual degradation in both fuel and oxidizer turbine efficiency. A decision tree was trained using 11 of these simulations, and tested using the remaining 45 simulations. In the training phase, the C4.5 algorithm was provided with labeled examples of data from nominal operation and data including leaks in each leak location. From the data, it "learned" a decision tree that can classify unseen data as having no leak or having a leak in one of the five leak locations. In the test phase, the decision tree produced very low false alarm rates and low missed detection rates on the unseen data. It had very good fault isolation rates for three of the five simulated leak locations, but it tended to confuse the remaining two locations, perhaps because a large leak at one of these two locations can look very similar to a small leak at the other location.

Schwabacher, Mark A.↗

Architectural concepts and redundancy techniques in fault-tolerant computers

This paper presents a description of redundancy techniques employed in the design of fault-tolerant computers, and a discussion of the effects of functional requirements, technology constraints, and cost considerations which enter into the choice of these techniques. The STAR computer, developed at the Jet Propulsion Laboratory for long-duration planetary spacecraft missions, is discussed along with several later fault-tolerant computer designs. The class of computers described in this paper employs dynamic redundancy, i.e., the machine is divided into a set of submodules, each with standby spares; a special hard core monitor unit detects and diagnoses faults, and effects automated recovery by replacing failed parts.

Rennels, D. A.↗

Detection of small earthquakes with dense array data: example from the San Jacinto fault zone, southern California

We present a technique to detect small earthquakes not included in standard catalogues using data from a dense seismic array. The technique is illustrated with continuous waveforms recorded in a test day by 1108 vertical geophones in a tight array on the San Jacinto fault zone. Waveforms are first stacked without time-shift in nine non-overlapping subarrays to increase the signal-to-noise ratio. The nine envelope functions of the stacked records are then multiplied with each other to suppress signals associated with sources affecting only some of the nine subarrays. Running a short-term moving average/long-term moving average (STA/LTA) detection algorithm on the product leads to 723 triggers in the test day. Using a local P-wave velocity model derived for the surface layer from Betsy gunshot data, 5 s long waveforms of all sensors around each STA/LTA trigger are beamformed for various incident directions. Of the 723 triggers, 220 are found to have localized energy sources and 103 of these are confirmed as earthquakes by verifying their observation at 4 or more stations of the regional seismic network. This demonstrates the general validity of the method and allows processing further the validated events using standard techniques. The number of validated events in the test day is >5 times larger than that in the standard catalogue. Using these events as templates can lead to additional detections of many more earthquakes.

58 GEOSCIENCES↗

Conceptual Machine Learning Strategy for Maintenance of Molten Salt Heat Exchanger

This report addresses the requirements of Milestone M3.2 Define maintenance scenarios and benchmarks. Development of digital twins (DT) for molten salt reactor (MSR) components is crucial for reducing operating and maintenance costs (O&M) and ensuring commercial viability of these reactors. Our focus is on development of DT for MSR primary system heat exchanger (HX), a critical component, the fault in which can reduce operating efficiency and force reactor shutdown. We are investigating feasibility of a conceptual DT of HX consisting of internal distributed temperature sensing with fiber optics and machine learning (ML) algorithms to detect and localize faults.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Advanced Sensor Deployment for Distribution System State Estimation and Fault Identification: Preprint

Distribution systems are currently facing steep operational challenges as a result of the rapidly increasing integration of renewables and other distributed energy resources (DERs)at both the primary and secondary circuit levels. Distribution utilities and system operators have traditionally had some visibility of their primary circuits using low-frequency supervisory control and data acquisition systems, and they have had very poor if not zero visibility of the secondary circuits where the presence of DERs is constantly increasing. Therefore, this paper presents simulation studies to demonstrate the benefits of an advanced, high-fidelity sensor technology, called as the Meta-Alert System (MAS), developed by Electrical Grid Monitoring Ltd. (EGM), on the distribution grid. First, a reliable model of the EGM sensors is developed, and then two use cases - distribution system state estimation (DSSE) and fault identification - are simulated to evaluate the performance of the MAS technology. Simulation results on the Electric Power Research Institute J1feeder demonstrate that the MAS can effectively participate in system-level DSSE programs and can detect and locate faults faster than traditional distribution protection schemes.

distribution system monitoring↗

Explainable machine learning for incipient anomaly detection in compact molten salt heat exchanger with overlapping feature distributions

High-temperature molten salt-cooled reactors (MSCRs) are a promising next-generation nuclear technology option, offering efficient power conversion and inherent safety features. However, the reliability of these systems depends on the robust operation of heat exchangers (HXs), which are susceptible to failure due to temperature gradients and channel plugging caused by fluid freezing. Conventional monitoring methods, relying on inlet and outlet measurements, lack the spatial resolution needed to detect early-stage faults. We propose a novel design of a compact salt-to-salt matrix-type HX design consisting of interleaved arrays of parallel tubes, with integrated synthetic fiber optic distributed temperature sensing (DTS) to enable localized detection of incipient faults. To evaluate performance of this design, we generate high-fidelity synthetic data using heat transfer computational modeling to simulate channel plugging, and introduce sensor noise for realistic modeling of measurements. The dataset comprises of 97% normal operation and 3% anomaly cases, with each anomaly class representing 1% of the data. These early anomalies result in overlapping temperature profiles between normal and faulty channels, producing a non-separable dataset that challenges traditional classification techniques. We benchmark eight supervised machine learning (ML) models and demonstrate that XGBoost achieves the highest performance. To improve transparency, we develop an explainability framework combining Shapley values and partially ordered sets (POSETs) to quantify and structurally analyze feature importance. This approach identifies both dominant predictors and ambiguous feature relationships, enhancing trust and interpretability. Our results highlight the potential of combining DTS and explainable ML with intelligent feature selection to improve predictive maintenance and ensure operational resilience in advanced nuclear systems.

Prantikos, Konstantinos [Argonne National Laborato↗

Visualizing Fault Induced Traveling Waves In Medium Voltage Systems

Traveling waves are induced in power systems during most transient events in the grid. These waves travel close to the speed of light in overhead lines and 50% to 60% the speed of light in underground cables. Even though traveling wave-based protection schemes for transmission systems are available commercially, traveling waves in medium voltage distribution networks are still in research space. Compared to transmission system, medium voltage distribution systems contain more reflections and refractions. Thus, visualization is challenging and is critical in locating faults in distribution network. To address this visualization challenge, this paper presents an open-source tool to visualize the traveling waves using Bewley lattice approach. The developed visualization tool will be useful for the protection engineers to detect and triangulate fault locations in the medium voltage systems and isolate the faults.

Bewley Lattice↗

Care 3 phase 2 report, maintenance manual

CARE 3 (Computer-Aided Reliability Estimation, version three) is a computer program designed to help estimate the reliability of complex, redundant systems. Although the program can model a wide variety of redundant structures, it was developed specifically for fault-tolerant avionics systems--systems distinguished by the need for extremely reliable performance since a system failure could well result in the loss of human life. It substantially generalizes the class of redundant configurations that could be accommodated, and includes a coverage model to determine the various coverage probabilities as a function of the applicable fault recovery mechanisms (detection delay, diagnostic scheduling interval, isolation and recovery delay, etc.). CARE 3 further generalizes the class of system structures that can be modeled and greatly expands the coverage model to take into account such effects as intermittent and transient faults, latent faults, error propagation, etc.

Bryant, L. A.↗

A fault injection experiment using the AIRLAB Diagnostic Emulation Facility

The preparation for, conduct of, and results of a simulation based fault injection experiment conducted using the AIRLAB Diagnostic Emulation facilities is described. An objective of this experiment was to determine the effectiveness of the diagnostic self-test sequences used to uncover latent faults in a logic network providing the key fault tolerance features for a flight control computer. Another objective was to develop methods, tools, and techniques for conducting the experiment. More than 1600 faults were injected into a logic gate level model of the Data Communicator/Interstage (C/I). For each fault injected, diagnostic self-test sequences consisting of over 300 test vectors were supplied to the C/I model as inputs. For each test vector within a test sequence, the outputs from the C/I model were compared to the outputs of a fault free C/I. If the outputs differed, the fault was considered detectable for the given test vector. These results were then analyzed to determine the effectiveness of some test sequences. The results established coverage of selt-test diagnostics, identified areas in the C/I logic where the tests did not locate faults, and suggest fault latency reduction opportunities.

Baker, Robert↗

Visualizing Fault Induced Traveling Waves in Medium Voltage Systems: Preprint

Traveling waves are induced in power systems during most transient events in the grid. These waves travel close to the speed of light in overhead lines and 50% to 60% the speed of light in underground cables. Even though traveling wave-based protection schemes for transmission systems are available commercially, traveling waves in medium voltage distribution networks are still in research space. Compared to transmission system, medium voltage distribution systems contain more reflections and refractions. Thus, visualization is challenging and is critical in locating faults in distribution network. To address this visualization challenge, this paper presents an open-source tool to visualize the traveling waves using Bewley lattice approach. The developed visualization tool will be useful for the protection and safety engineers to detect and triangulate fault locations in the medium voltage systems and isolate the faults.

Bewley Lattice↗

Measurement of fault latency in a digital avionic miniprocessor

The results of fault injection experiments utilizing a gate-level emulation of the central processor unit of the Bendix BDX-930 digital computer are presented. The failure detection coverage of comparison-monitoring and a typical avionics CPU self-test program was determined. The specific tasks and experiments included: (1) inject randomly selected gate-level and pin-level faults and emulate six software programs using comparison-monitoring to detect the faults; (2) based upon the derived empirical data develop and validate a model of fault latency that will forecast a software program's detecting ability; (3) given a typical avionics self-test program, inject randomly selected faults at both the gate-level and pin-level and determine the proportion of faults detected; (4) determine why faults were undetected; (5) recommend how the emulation can be extended to multiprocessor systems such as SIFT; and (6) determine the proportion of faults detected by a uniprocessor BIT (built-in-test) irrespective of self-test.

Mcgough, J. G.↗

A scheme for fault tolerance in earth sensors

A system is presented that uses dual-redundant earth sensors to measure pitch and roll errors of a three-axis stabilized spacecraft, with provision for (1) autonomously detecting and identifying a faulty earth sensor, and (2) automatically selecting the outputs of the fault-free sensor for closed-loop attitude control, before failures cause major problems. A brief description is given of the system, and various failure modes of earth sensors and their effects are discussed. Novel techniques and algorithms for automatic fault detection, identification, and reconfiguration (FDIR) of dual-redundant earth sensors are developed. The algorithms are validated through computer simulations, and the results are presented. The proposed scheme can easily be implemented without much penalty on hardware, power consumption, and processing time.

Murugesan, S.↗