Maximum likelihood method for fitting a sum of exponentials to experimental data
Maximum likelihood method for fitting sum of expotentials to experimental data
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Maximum likelihood method for fitting sum of expotentials to experimental data
Proteins with intrinsic or unfolded state disorder comprise a new frontier in structural biology, requiring the characterization of diverse and dynamic structural ensembles. Here we introduce a comprehensive Bayesian framework, the Extended Experimental Inferential Structure Determination (X-EISD) method, which calculates the maximum log-likelihood of a disordered protein ensemble. X-EISD accounts for the uncertainties of a range of experimental data and back-calculation models from structures, including NMR chemical shifts, J-couplings, Nuclear Overhauser Effects (NOEs), paramagnetic relaxation enhancements (PREs), residual dipolar couplings (RDCs), hydrodynamic radii (R h ), single molecule fluorescence Förster resonance energy transfer (smFRET) and small angle X-ray scattering (SAXS). We apply X-EISD to the joint optimization against experimental data for the unfolded drkN SH3 domain and find that combining a local data type, such as chemical shifts or J-couplings, paired with long-ranged restraints such as NOEs, PREs or smFRET, yields structural ensembles in good agreement with all other data types if combined with representative IDP conformers.
Purpose: Beam-shaping or ''bow tie'' (BT) filters are used to spatially modulate the x-ray beam in a CT scanner, but the conventional method of step-and-shoot measurement to characterize a beam's profile is tedious and time-consuming. The theory for characterization of bow tie relative attenuation (COBRA) method, which relies on a real-time dosimeter to address the issues of conventional measurement techniques, was previously demonstrated using computer simulations. In this study, the feasibility of the COBRA theory is further validated experimentally through the employment of a prototype real-time radiation meter and a known BT filter. Methods: The COBRA method consisted of four basic steps: (1) The probe was placed at the edge of a scanner's field of view; (2) a real-time signal train was collected as the scanner's gantry rotated with the x-ray beam on; (3) the signal train, without a BT filter, was modeled using peak values measured in the signal train of step 2; and (4) the relative attenuation of the BT filter was estimated from filtered and unfiltered data sets. The prototype probe was first verified to have an isotropic and linear response to incident x-rays. The COBRA method was then tested on a dedicated breast CT scanner with a custom-designed BT filter and compared to the conventional step-and-shoot characterization of the BT filter. Using basis decomposition of dual energy signal data, the thickness of the filter was estimated and compared to the BT filter's manufacturing specifications. The COBRA method was also demonstrated with a clinical whole body CT scanner using the body BT filter. The relative attenuation was calculated at four discrete x-ray tube potentials and used to estimate the thickness of the BT filter. Results: The prototype probe was found to have a linear and isotropic response to x-rays. The relative attenuation produced from the COBRA method fell within the error of the relative attenuation measured with the step-and-shoot method. The BT filter thickness estimates resulting from the dual energy scans on the breast CT system were equivalent to the manufacturing specifications. The clinical CT evaluation produced data conceptually similar to previous computer simulations and plausible relative attenuation profiles were observed. Conclusions: The COBRA method is a fast and accurate method for BT filter characterization, which requires a simple experimental setup in a clinical environment. Because of the ease of data acquisition, multienergy scans can be acquired which allow characterization of the BT filter thickness.
This study deals with comparison of Cameroonian ground based measurements with estimations done using satellite images, by applying the second version of the HELIOSAT method, as computed by the web tool HELIOCLIM of the SoDa project. Measurements and satellite resources were chosen for the same period of the year 1985, on ten Cameroonian locations, distributed with mean spatial resolution of 200 km between two neighbouring stations. Correlations curves are constructed between daily irradiation estimates from satellite data and from measurements. The consequent regression equations are established, using the least square method. Finally, a brief discussion is carried out on the spatial distribution of errors observed on results. Similarly to previous studies this study confirmed the capability of the method to produce good results for the Garoua location, and established its extension on other sahelian sites, comparatively to the poor agreement observed on southern sites. Furthermore, even if the study was not done on a long period, it brought out the necessity to correct the HELIOSAT results for many Cameroonian locations, to march the experimental results. (author)
The Langley Research Center of the National Aeronautics and Space Administration and the Royal Aircraft Establishment have undertaken a cooperative program to conduct an assessment of their patched viscous-inviscid interaction methods for predicting the transonic flow over nozzle afterbodies. The assessment was made by comparing the predictions of the two methods with experimental pressure distributions and boattail pressure drag for several convergent circular-arc nozzle configurations. Comparisons of the predictions of the two methods with the experimental data showed that both methods provided good predictions of the flow characteristics of nozzles with attached boundary layer flow. The RAE method also provided reasonable predictions of the pressure distributions and drag for the nozzles investigated that had separated boundary layers. The NASA method provided good predictions of the pressure distribution on separated flow nozzles that had relatively thin boundary layers. However, the NASA method was in poor agreement with experiment for separated nozzles with thick boundary layers due primarily to deficiencies in the method used to predict the separation location.
We present a review of the experimental and theoretical methods used in the discovery of new metal-hydrogen materials systems for hydrogen storage applications. Rather than a comprehensive review of all new materials and methods used in the metal hydride community, we focus on a specific subset of successful methods utilizing theoretical crystal structure prediction methods, computational approaches for screening large numbers of compound classes, and medium-throughput experimental methods for the preparation of such materials. Monte Carlo techniques paired with a simplified empirical Hamiltonian provide crystal structure candidates that are refined using Density Functional Theory. First-principle methods using high-quality structural candidates are further screened for an estimate of reaction energetics, decomposition enthalpies, and determination of reaction pathways. Experimental synthesis utilizes a compacted-pellet sintering technique under high-pressure hydrogen at elevated temperatures. Crystal structure determination follows from a combination of Rietveld refinements of diffraction patterns and first-principles computation of total energies and dynamical stability of competing structures. The methods presented within are general and applicable to a wide class of materials for energy storage.
Purpose: Automatic prostate segmentation from MR images is an important task in various clinical applications such as prostate cancer staging and MR-guided radiotherapy planning. However, the large appearance and shape variations of the prostate in MR images make the segmentation problem difficult to solve. Traditional Active Shape/Appearance Model (ASM/AAM) has limited accuracy on this problem, since its basic assumption, i.e., both shape and appearance of the targeted organ follow Gaussian distributions, is invalid in prostate MR images. To this end, the authors propose a sparse dictionary learning method to model the image appearance in a nonparametric fashion and further integrate the appearance model into a deformable segmentation framework for prostate MR segmentation. Methods: To drive the deformable model for prostate segmentation, the authors propose nonparametric appearance and shape models. The nonparametric appearance model is based on a novel dictionary learning method, namely distributed discriminative dictionary (DDD) learning, which is able to capture fine distinctions in image appearance. To increase the differential power of traditional dictionary-based classification methods, the authors' DDD learning approach takes three strategies. First, two dictionaries for prostate and nonprostate tissues are built, respectively, using the discriminative features obtained from minimum redundancy maximum relevance feature selection. Second, linear discriminant analysis is employed as a linear classifier to boost the optimal separation between prostate and nonprostate tissues, based on the representation residuals from sparse representation. Third, to enhance the robustness of the authors' classification method, multiple local dictionaries are learned for local regions along the prostate boundary (each with small appearance variations), instead of learning one global classifier for the entire prostate. These discriminative dictionaries are located on different patches of the prostate surface and trained to adaptively capture the appearance in different prostate zones, thus achieving better local tissue differentiation. For each local region, multiple classifiers are trained based on the randomly selected samples and finally assembled by a specific fusion method. In addition to this nonparametric appearance model, a prostate shape model is learned from the shape statistics using a novel approach, sparse shape composition, which can model nonGaussian distributions of shape variation and regularize the 3D mesh deformation by constraining it within the observed shape subspace. Results: The proposed method has been evaluated on two datasets consisting of T2-weighted MR prostate images. For the first (internal) dataset, the classification effectiveness of the authors' improved dictionary learning has been validated by comparing it with three other variants of traditional dictionary learning methods. The experimental results show that the authors' method yields a Dice Ratio of 89.1% compared to the manual segmentation, which is more accurate than the three state-of-the-art MR prostate segmentation methods under comparison. For the second dataset, the MICCAI 2012 challenge dataset, the authors' proposed method yields a Dice Ratio of 87.4%, which also achieves better segmentation accuracy than other methods under comparison. Conclusions: A new magnetic resonance image prostate segmentation method is proposed based on the combination of deformable model and dictionary learning methods, which achieves more accurate segmentation performance on prostate T2 MR images.
The identification of the nature of dark matter is one of the most important problems confronting particle physics. Current observational constraints permit the mass of the dark matter to range from 10^{-22} 10 − 22 eV - 10^{48} 10 48 GeV. Given the weak nature of these bounds and the ease with which dark matter models can be constructed, it is clear that the problem can only be solved experimentally. In these lectures, I discuss methods to experimentally probe a wide range of dark matter candidates.
Explore the source record for details and available documents.
The synthesis, structure, and magnetic properties are reported for [Fe 7 O 3 (O 2 C t Bu) 9 (mda) 3 (H 2 O) 3 ] ( 1 ), where mdaH 2 is N -methyldiethanolamine. 1 was prepared from the reaction of [Fe 3 O(O 2 C t Bu) 6 (H 2 O) 3 ](NO 3 ) with mdaH 2 in a 1:~3 ratio in MeCN. The core of 1 consists of a central octahedral Fe III ion held within a non-planar Fe 6 loop by three μ 3 -O 2- and three μ 2 -RO - arms from the three mda 2- chelates. Variable-temperature dc and ac magnetic susceptibility studies revealed dominant antiferromagnetic coupling, leading to a ground state spin of S = 5 / 2 . The ground state was confirmed by a fit of magnetization data collected in the 0.1–7.0 T and 1.8–10.0 K ranges. The four Fe 2 pairwise exchange parameters ( J 1 - J 4 ) were estimated by independent methods: theoretical calculations using either broken symmetry energy differences (-46.3, -16.2, -3.9, and - 28.1 cm -1 , respectively) or Green’s function approximation methods (-41.4, -14.8, -13.2, and - 24.7 cm -1 ), and a magnetostructural correlation (MSC) previously developed for high nuclearity Fe III /O complexes (-39.5, -13.8, -6.7, and - 23.5 cm -1 ). Additionally, the J 1 - J 4 obtained from the MSC and theoretical methods were used with the program PHI to both simulate χ M T vs T as well as to serve as reasonable input values to fit the experimental data (-41.0, -11.4, -5.0, and - 27.3 cm -1 ). Analysis of the J ij led to identification of the spin frustration effects operative and the resultant spin vector alignments at each Fe III ion, thus allowing for the rationalization of the experimental ground state.
The current computational techniques available for biomolecular simulation are described, and the successes and limitations of each with reference to the experimental biophysical methods that they complement are presented. Despite huge advances in the computational techniques available for simulating biomolecules at the quantum-mechanical, atomistic and coarse-grained levels, there is still a widespread perception amongst the experimental community that these calculations are highly specialist and are not generally applicable by researchers outside the theoretical community. In this article, the successes and limitations of biomolecular simulation and the further developments that are likely in the near future are discussed. A brief overview is also provided of the experimental biophysical methods that are commonly used to probe biomolecular structure and dynamics, and the accuracy of the information that can be obtained from each is compared with that from modelling. It is concluded that progress towards an accurate spatial and temporal model of biomacromolecules requires a combination of all of these biophysical techniques, both experimental and computational.
The bending stresses in the covers of box beams or wide-flange beams differ appreciably from the stresses predicted by the ordinary bending theory on account of shear deformation of the flanges. The problem of predicting these differences has become known as the shear-lag problem. The first part of this paper deals with methods of shear-lag analysis suitable for practical use. The second part of the paper describes strain-gage tests made by the NACA to verify the theory. Three tests published by other investigators are also analyzed by the proposed method. The third part of the paper gives numerical examples illustrating the methods of analysis. An appendix gives comparisons with other methods, particularly with the method of Ebner and Koller.
Various methods for calculating the transmission functions of the 15 micron CO2 band are described. The results of these methods are compared with laboratory measurements. It is found that program P4 provides the best agreement with experimental results on the average.
Theoretical and experimental studies are described which were conducted for the purpose of developing a new generalized method for the prediction of profile drag of single component airfoil sections with sharp trailing edges. This method aims at solution for the flow in the wake from the airfoil trailing edge to the large distance in the downstream direction; the profile drag of the given airfoil section can then easily be obtained from the momentum balance once the shape of velocity profile at a large distance from the airfoil trailing edge has been computed. Computer program subroutines have been developed for the computation of the profile drag and flow in the airfoil wake on CDC6600 computer. The required inputs to the computer program consist of free stream conditions and the characteristics of the boundary layers at the airfoil trailing edge or at the point of incipient separation in the neighborhood of airfoil trailing edge. The method described is quite generalized and hence can be extended to the solution of the profile drag for multi-component airfoil sections.
This technical report documents the surrogate reaction method and experimental results used to determine the desired neutron induced cross sections of 87 Y(n,g) and the known 90 Zr(n,g) cross section. This experiment was performed at the STARLiTeR apparatus located at Texas A&M Cyclotron Institute using the K150 Cyclotron which produced a 28.56 MeV proton beam. The proton beam impinged on Y and Zr targets to produce the nuclear reactions 89 Y(p,d) 88 Y and 92 Zr(p,d) 91 Zr. Both particle singles data and particle-gamma ray coincident data were measured during the experiment. This data was used to determine the γ-ray probability as a function of energy for these reactions. The results for the γ-ray probabilities as a function of energy for both these nuclei are documented here. For completeness, extensive tabulated and graphical results are provided in the appendices.
A method is developed for determining acoustic liner admittance in a rectangular duct with grazing flow. The axial propagation constant, cross mode order, and mean flow profile is measured. These measured data are then input into an analytical program which determines the unknown admittance value. The analytical program is based upon a finite element discretization of the acoustic field and a reposing of the unknown admittance value as a linear eigenvalue problem on the admittance value. Gaussian elimination is employed to solve this eigenvalue problem. The method used is extendable to grazing flows with boundary layers in both transverse directions of an impedance tube (or duct). Predicted admittance values are compared both with exact values that can be obtained for uniform mean flow profiles and with those from a Runge Kutta integration technique for cases involving a one dimensional boundary layer.
Purpose: New definitions for some dosimetric parameters for use in quality assurance of flattening filter free (FFF) beams generated by medical linear accelerators have been suggested. The present study aims to validate these suggestions and to propose possible reference levels. Methods: The main characteristics of FFF photon beams were described in terms of: field size, penumbra, unflatness, slope, and peak-position parameters. Data were collected for 6 and 10 MV-FFF beams from three different Varian TrueBeam Linacs. Measurements were performed with a 2D-array (Starcheck system from PTW-Freiburg) and with the portal dosimetry method GLAaS utilizing the build-in portal imager of TrueBeam. Data were also compared to ion chamber measurements. A cross check validation has been performed on a FFF beam of 6 MV generated by a Varian Clinac-iX upgraded to FFF capability. Results : All the parameters suggested to characterize the FFF beams resulted easily measurable and little variation was observed among different Linacs. Referring to two reference field sizes of 10 × 10 and 20 × 20 cm{sup 2}, at SDD = 100 cm and d = dmax, from the portal dosimetry data, the following results (averaging X and Y profiles) were obtained. Field size: 9.95 ± 0.02 and 19.98 ± 0.03 cm for 6 MV-FFF (9.94 ± 0.02 and 19.98 ± 0.03 cm for 10 MV-FFF). Penumbra: 2.7 ± 0.3 and 2.9 ± 0.3 mm for 6 MV-FFF (3.1 ± 0.2 and 3.3 ± 0.3 for 10 MV-FFF). Unflatness: 1.11 ± 0.01 and 1.25 ± 0.01 for 6 MV-FFF (1.21 ± 0.01 and 1.50 ± 0.01 for 10 MV-FFF). Slope: 0.320 ± 0.020%/mm and 0.43 ± 0.015%/mm for 6 MV-FFF (0.657 ± 0.023%/mm and 0.795 ± 0.017%/mm for 10 MV-FFF). Peak Position −0.2 ± 0.2 and −0.4 ± 0.2 mm for 6 MV-FFF (−0.3 ± 0.2 and 0.7 ± 0.3 mm for 10 MV-FFF). Results would depend upon measurement depth. With thresholds set to at least 95% confidence level from the measured data and to account for possible variations between detectors and methods and experimental settings, a tolerance set of: 1 mm for field size and penumbra, 0.04 for unflatness, 0.1%/mm for slope, and 1 mm for peak position could be proposed from our data. Conclusions : The parameters proposed for the characterization and routine control of stability of profiles of FFF beams appear to be a viable solution with a strong similarity to the conventional parameters used for flattened beams. The results from three different TrueBeams and the cross-validation against a Clinac-iX suggested the possible generalization of the methods and the possibility to use common tolerances for the parameters. The data showed also the reproducibility of beam characteristics among different systems (of the same vendor) and the resulting parameter values could therefore be possibly generalized.
National security programs have expressed interest in developing systems to isotopically map shipping containers, fuel assemblies, and waste barrels for various materials including special nuclear material (SNM). Current radiographic systems offer little more than an ambiguous density silhouette of a container's contents. In this paper we will present a system being developed at LLNL to isotopically map containers using the nuclear resonance fluorescence (NRF) method. Recent experimental measurements on NRF strengths in SNM are discussed.