Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “error performance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,351 records · Page 75

Fast HARDI Uncertainty Quantification and Visualization with Spherical Sampling

In this paper, we study uncertainty quantification and visualization of orientation distribution functions (ODF), which corresponds to the diffusion profile of high angular resolution diffusion imaging (HARDI) data. The shape inclusion probability (SIP) function is the state‐of‐the‐art method for capturing the uncertainty of ODF ensembles. The current method of computing the SIP function with a volumetric basis exhibits high computational and memory costs, which can be a bottleneck to integrating uncertainty into HARDI visualization techniques and tools. We propose a novel spherical sampling framework for faster computation of the SIP function with lower memory usage and increased accuracy. In particular, we propose direct extraction of SIP isosurfaces, which represent confidence intervals indicating spatial uncertainty of HARDI glyphs, by performing spherical sampling of ODFs. Our spherical sampling approach requires much less sampling than the state‐of‐the‐art volume sampling method, thus providing significantly enhanced performance, scalability, and the ability to perform implicit ray tracing. Our experiments demonstrate that the SIP isosurfaces extracted with our spherical sampling approach can achieve up to 8164× speedup, 37282× memory reduction, and 50.2% less SIP isosurface error compared to the classical volume sampling approach. We demonstrate the efficacy of our methods through experiments on synthetic and human‐brain HARDI datasets.

97 MATHEMATICS AND COMPUTING↗

Misclassification of causes of death among a small all-autopsied group of former nuclear workers: Death certificates vs. autopsy reports

The U.S. Transuranium and Uranium Registries performs autopsies on each of its deceased Registrants as a part of its mission to follow up occupationally-exposed individuals. This provides a unique opportunity to explore death certificate misclassification errors, and the factors that influence them, among this small population of former nuclear workers. Underlying causes of death from death certificates and autopsy reports were coded using the 10 th revision of the International Classification of Diseases (ICD-10). These codes were then used to quantify misclassification rates among 268 individuals for whom both full autopsy reports and death certificates with legible underlying causes of death were available. When underlying causes of death were compared between death certificates and autopsy reports, death certificates correctly identified the underlying cause of death’s ICD-10 disease chapter in 74.6% of cases. The remaining 25.4% of misclassified cases resulted in over-classification rates that ranged from 1.2% for external causes of mortality to 12.2% for circulatory disease, and under-classification rates that ranged from 7.7% for external causes of mortality to 47.4% for respiratory disease. Neoplasms had generally lower misclassification rates with 4.3% over-classification and 13.3% under-classification. A logistic regression revealed that the odds of a match were 2.8 times higher when clinical history was mentioned on the autopsy report than when it was not. Similarly, the odds of a match were 3.4 times higher when death certificates were completed using autopsy findings than when autopsy findings were not used. This analysis excluded cases where it could not be determined if autopsy findings were used to complete death certificates. The findings of this study are useful to investigate the impact of death certificate misclassification errors on radiation risk estimates and, therefore, improve the reliability of epidemiological studies.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

SOC Microstructural Property Estimator

This pre-trained ML model is a tool that uses basic compositional parameters for porous solid oxide cell (SOC) electrodes - the phase fractions and mean particle/pore diameters – as inputs and uses them to estimate additional electrochemical performance parameters: active (i.e., connected) TPB density, all tortuosity factors, and phase pair specific interfacial areas. The electrode is assumed to be composed of two solid phases and a pore phase. The property calculations are performed using neural network regression models trained on a large bank of synthetic electrode microstructural data that NETL has generated using the program DREAM3D (that bank is also hosted on EDX: https://edx.netl.doe.gov/dataset/soc-synthetic-microstructure-bank). This means the generated parameters are based on training from actual measured properties from 3D microstructures, not estimated from geometric simplifications. This tool was developed and is intended to replace percolation theory calculations in models that use hypothetical electrode properties. An example use case would be running SOC performance simulations across a parametric sweep of electrode designs (e.g., varying phase fractions and particle sizes) and assessing how it impacts the electrochemical performance of the SOC. Within the parameter space of the training data (statistics of that parameter space is provided in the readme file), this model achieves sub-5% mean absolute percent errors, an order of magnitude less error than percolation theory across the same parameter space. However, be aware that this tool was developed with parametric simulations in mind, and users are encouraged to assess accuracy for their own specific use case rather than taking accuracy metrics at face value. More info, including a usage guide, is in the included readme file. This tool should be cited with the DOI number provided.

Electrode Microstructure↗

Fast-, Light-Cured Scintillating Plastic for 3D-Printing Applications

Additive manufacturing techniques enable a wide range of possibilities for novel radiation detectors spanning simple to highly complex geometries, multi-material composites, and metamaterials that are either impossible or cost prohibitive to produce using conventional methods. The present work identifies a set of promising formulations of photocurable scintillator resins capable of neutron-gamma pulse shape discrimination (PSD) to support the additive manufacturing of fast neutron detectors. The development of these resins utilizes a step-by-step, trial-and-error approach to identify different monomer and cross-linker combinations that meet the requirements for 3D printing followed by a 2-level factorial parameter study to optimize the radiation detection performance, including light yield, PSD, optical clarity, and hardness. The formulations resulted in hard, clear, PSD-capable plastic scintillators that were cured solid within 10 s using 405 nm light. The best-performing scintillator produced a light yield 83% of EJ-276 and a PSD figure of merit equaling 1.28 at 450–550 keVee.

Frandsen, Brian G. (ORCID:0000000319964320)↗

Li-ion Battery Material phase prediction through Hierarchical Curriculum Learning

Li-ion Batteries (LIB), one of the most efficient energy storage devices, are widely adopted in many industrial applications. Imaging data of these battery electrodes obtained from X-ray tomography can explain the distribution of material constituents and allow reconstructions to study electron transport pathways. Therefore, it can eventually help quantify various associated properties of electrodes (e.g., volume-specific surface area, porosity) which determine the performance of batteries. However, these images often suffer from low image contrast between multiple material constituents , making it difficult for humans to distinguish and characterize these constituents through visualization. A minor error in detecting distributions among the material constituents can lead to a high error in the calculated parameters of material properties.We present a novel hierarchical curriculum learning framework to address the complex task of estimating material constituent distribution in battery electrodes. To provide spatially smooth prediction, our framework comprises three modules: (i) an uncertainty-aware model trained to yield inferences conditioned upon global knowledge of material distribution, (ii) a technique to capture relatively more fine-grained (local) distributional signals, (iii) an aggregator to appropriately fuse the local and global effects towards obtaining the final distribution.

Tabassum, Anika↗

Characterization and Analysis of the Energy-Reporting Accuracy of Connected Devices

Emerging energy-efficient building systems increasingly exhibit greater functionality, often requiring multiple operating modes (e.g. white-tunability for lighting products and data traffic for devices with networked, integrated sensors). This increased functionality makes energy consumption estimates more complex. Given that these functions consume energy, the energy performance of such building systems is dependent on what operating modes they use and how much time they spend in each mode. Devices and systems that can report their own energy consumption mitigate this energy-performance uncertainty. This study explores the energy-reporting accuracy of market-available connected electrical outlets. The study considers two residential-market products (five units each, one outlet per unit) and three commercial-market products (two units each, 18 to 24 outlets per unit) with the ability to report power drawn and/or energy consumed by devices connected to their receptacles. The products were purchased through typical market channels. Pacific Northwest National Laboratory (PNNL) conducted testing in December 2018 at its Connected Lighting Test Bed (CLTB), using a custom-developed test setup and method adapted from industry standards. The setup collected energy-consumption data reported by the outlet devices under test (DUTs) at one-minute intervals and compared that data with measurements taken by a reference meter over a range of test conditions. The residential products reported power draw but not interval or cumulative energy consumption. The commercial products reported both power draw and cumulative energy consumption. Relative reporting error (RRE) was calculated for all measurements, and analysis of the results revealed variations across devices and test conditions. The total number of measurements (50 for each residential product, 60 for each commercial product) offers an appreciable comparison of performance at the make/model level. The average RRE of the residential products derived from reported power draw was -0.02% and -1.20%. The average RRE for two of the three the commercial products derived from reported power draw was worse than those of the residential products (-2.40%, -2.72%, -0.36%). The internal integration of power over time, used to calculate cumulative energy consumption, typically occurs at current and voltage sampling rates much higher than once per minute. This suggests that the average commercial-product RRE derived from reported energy consumption should be very consistent and better than performance based on reported power draw. However, the RRE derived from reported energy consumption varied significantly across the three makes of commercial-market products and was uniformly less accurate than performance based on reported power draw. Subsequent analysis identified a number of root causes for this decrease in performance, most of which were related to reporting resolution. The goals of this study are to generate awareness of building systems capable of reporting their own energy consumption, further interest in the value of energy data for a variety of uses, draw attention to how the accuracy of reported metrics can be characterized, and quantify the performance variation found in marketavailable products. The results of this study and subsequent related work may be relevant to stakeholders in industry-specification and standards-development organizations. The methods this study employs could inform test and measurement procedures and performance classifications for connected outlets, lighting products, and other building systems capable of reporting their own energy consumption. The study concludes with stakeholder recommendations, including the following: • Energy-reporting device and system manufacturers developing products that report energy consumption should characterize the accuracy of reported metrics using a reference meter calibrated by an independent laboratory that was accredited by an ILAC MRA signatory (and whose scope of accreditation explicitly covers energy measurement), and should include this information on product data sheets. • Standards and specification development organizations should develop application-specific performance classifications that end users can understand and relate to their energy-data use needs (e.g., 2% accuracy class for utility streetlight energy billing needs, or 10% accuracy class for ESCO performance verification needs). • Current or potential owners, operators, and specifiers of energy-reporting building systems should rigorously analyze the dependency of current and planned energy-data use cases on accuracy, noting in particular the dependence (or lack thereof) on relative vs. absolute accuracy, and on trueness vs. precision (i.e., repeatability), and should communicate use-case needs to industry standards and specification organizations.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Characterization and Analysis of the Energy-Reporting Accuracy of Connected Devices

Emerging energy-efficient building systems increasingly exhibit greater functionality, often requiring multiple operating modes (e.g. white-tunability for lighting products and data traffic for devices with networked, integrated sensors). This increased functionality makes energy consumption estimates more complex. Given that these functions consume energy, the energy performance of such building systems is dependent on what operating modes they use and how much time they spend in each mode. Devices and systems that can report their own energy consumption mitigate this energy-performance uncertainty. This study explores the energy-reporting accuracy of market-available connected electrical outlets. The study considers two residential-market products (five units each, one outlet per unit) and three commercial-market products (two units each, 18 to 24 outlets per unit) with the ability to report power drawn and/or energy consumed by devices connected to their receptacles. The products were purchased through typical market channels. Pacific Northwest National Laboratory (PNNL) conducted testing in December 2018 at its Connected Lighting Test Bed (CLTB), using a custom-developed test setup and method adapted from industry standards. The setup collected energy-consumption data reported by the outlet devices under test (DUTs) at one-minute intervals and compared that data with measurements taken by a reference meter over a range of test conditions. The residential products reported power draw but not interval or cumulative energy consumption. The commercial products reported both power draw and cumulative energy consumption. Relative reporting error (RRE) was calculated for all measurements, and analysis of the results revealed variations across devices and test conditions. The total number of measurements (50 for each residential product, 60 for each commercial product) offers an appreciable comparison of performance at the make/model level. The average RRE of the residential products derived from reported power draw was -0.02% and -1.20%. The average RRE for two of the three the commercial products derived from reported power draw was worse than those of the residential products (-2.40%, -2.72%, -0.36%). The internal integration of power over time, used to calculate cumulative energy consumption, typically occurs at current and voltage sampling rates much higher than once per minute. This suggests that the average commercial-product RRE derived from reported energy consumption should be very consistent and better than performance based on reported power draw. However, the RRE derived from reported energy consumption varied significantly across the three makes of commercial-market products and was uniformly less accurate than performance based on reported power draw. Subsequent analysis identified a number of root causes for this decrease in performance, most of which were related to reporting resolution. The goals of this study are to generate awareness of building systems capable of reporting their own energy consumption, further interest in the value of energy data for a variety of uses, draw attention to how the accuracy of reported metrics can be characterized, and quantify the performance variation found in marketavailable products. The results of this study and subsequent related work may be relevant to stakeholders in industry-specification and standards-development organizations. The methods this study employs could inform test and measurement procedures and performance classifications for connected outlets, lighting products, and other building systems capable of reporting their own energy consumption. The study concludes with stakeholder recommendations, including the following: • Energy-reporting device and system manufacturers developing products that report energy consumption should characterize the accuracy of reported metrics using a reference meter calibrated by an independent laboratory that was accredited by an ILAC MRA signatory (and whose scope of accreditation explicitly covers energy measurement), and should include this information on product data sheets. • Standards and specification development organizations should develop application-specific performance classifications that end users can understand and relate to their energy-data use needs (e.g., 2% accuracy class for utility streetlight energy billing needs, or 10% accuracy class for ESCO performance verification needs). • Current or potential owners, operators, and specifiers of energy-reporting building systems should rigorously analyze the dependency of current and planned energy-data use cases on accuracy, noting in particular the dependence (or lack thereof) on relative vs. absolute accuracy, and on trueness vs. precision (i.e., repeatability), and should communicate use-case needs to industry standards and specification organizations.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Moving Embedded Boundary Approach for the Compressible Navier-Stokes Equations in a Block-Structured Adaptive Refinement Framework

A computational technique has been developed to perform compressible flow simulations involving moving boundaries using an embedded boundary approach within the block-structured adaptive mesh refinement (SAMR) framework of AMReX [1], [91], [92]. We leverage the SAMR capability to obtain quantitatively accurate results whilst using robust, second-order finite volume schemes. A conservative, unsplit, cut-cell approach is utilized and a ghost-cell approach is developed for computing the flux on the moving, embedded boundary faces. A third-order least-squares formulation has been developed to compute the wall velocity gradients, and was found to significantly improve the performance of the solver in terms of the quantitative comparison of surface quantities such as the skin friction coefficient. Various test cases are performed to validate the method, and compared with analytical, experimental, and other numerical results in literature. Inviscid and viscous test cases are performed that span a wide regime of flow speeds - acoustic (harmonically pulsating sphere), smooth flows (expansion fan created by a receding piston) and flows with shocks (shock-cylinder interaction, shock-wedge interaction, pitching NACA 0012 airfoil and shock-cone interaction). A closed system with moving boundaries - an oscillating piston in a cylinder, showed that the percentage error in mass within the system decreases with refinement, demonstrating that the numerical scheme is conservative with grid refinement, but is not discretely conservative. Viscous test cases involve that of a horizontally moving cylinder at Re = 40, an inline oscillating cylinder at Re = 100, and a transversely oscillating cylinder at Re = 185. The judicious use of adaptive mesh refinement with appropriate refinement criteria to capture the regions of interest leads to well-resolved flow features, and good quantitative comparison is observed with the results available in literature.

adaptive refinement↗

Flow condensation heat transfer performance of natural and emerging synthetic refrigerants

There is great interest in predicting flow condensation heat transfer for lower global warming potential (GWP) fluids. This paper analyzes the efficacy of common flow condensation correlations developed for particular fluids in order to identify their suitability to predict heat transfer performance of low GWP fluids. Condensation heat transfer data were extracted from the literature, including 19 papers and 1,473 data points for natural refrigerants [i.e., ammonia (R717), CO 2 (R744), propane (R290), isobutane (R600a)] and 35 papers and 5,030 data points for synthetic refrigerants [i.e., R12, R1234yf, R1234ze(E), R1234ze(Z), R22, R32, R41, R123, R125, R134a, R142b, R152a, R161, R404A, R410A, R448A, R449A, R450A, R452B, R454C, R455A, R513A] encompassing tube diameters of 0.1–11.5 mm, mass fluxes of 55–1200 kg/m2s, and saturation temperatures of -25°C–65°C. Correlations analyzed included Akers et al. (1959), Cavallini et al. (2006, 2011), Kim and Mudawar (2013), Macdonald and Garimella (2016), Shah (1979, 2009, 2013, 2016) and Traviss et al. (1973) for smooth tubes and Chamra et al. (2005) and Kedzierski and Goncalves (1999) for enhanced tubes. Since most studies did not report wall temperature, correlations which relied on wall temperature directly or indirectly were excluded from the analysis. For synthetic refrigerants, mean average error (MAE) ranged from 6%–257%, and Cavallini et al. (2011) and Kim and Mudawar (2013) were the best predictors for emerging synthetic refrigerants. Furthermore, the Kim and Mudawar (2013) correlation was found to best predict the heat transfer performance for propane and R600a data, but most correlations did not accurately predict ammonia and CO 2 flow condensation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

More buck-per-shot: Why learning trumps mitigation in noisy quantum sensing

Quantum sensing is one of the most promising applications for quantum technologies. However, reaching the ultimate sensitivities enabled by the laws of quantum mechanics can be a challenging task in realistic scenarios where noise is present. While several strategies have been proposed to deal with the detrimental effects of noise, these come at the cost of an extra shot budget. Given that shots are a precious resource for sensing – as infinite measurements could lead to infinite precision – care must be taken to truly guarantee that any shot not being used for sensing is actually leading to some metrological improvement. In this work, we study whether investing shots in error-mitigation, inference techniques, or combinations thereof, can improve the sensitivity of a noisy quantum sensor on a (shot) budget. We present a detailed bias–variance error analysis for various sensing protocols. Our results show that the costs of zero-noise extrapolation techniques outweigh their benefits. We also find that pre-characterizing a quantum sensor via inference techniques leads to the best performance, under the assumption that the sensor is sufficiently stable.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

$\mathrm{PPT}$-Multicore: performance prediction of Open$\mathrm{MP}$ applications using reuse profiles and analytical modeling

In this report we present PPT-Multicore, an analytical model embedded in the Performance Prediction Toolkit (PPT) to predict parallel applications’ performance running on a multicore processor. PPT-Multicore builds upon our previous work towards a multicore cache model. We extract LLVM basic block labeled memory trace using an architecture-independent LLVM-based instrumentation tool only once in an application’s lifetime. The model uses the memory trace and other parameters from an instrumented sequentially executed binary. We use probabilistic and computationally efficient reuse profiles to predict the cache hit rates and runtimes of OpenMP programs’ parallel sections. We model Intel’s Broadwell, Haswell, and AMD’s Zen2 architectures and validate our framework using different applications from PolyBench and PARSEC benchmark suites. The results show that PPT-Multicore can predict cache hit rates with an overall average error rate of 1.23% while predicting the runtime with an error rate of 9.08%.

97 MATHEMATICS AND COMPUTING↗

Validation of URANS and STRUCT-ε turbulence models for stratified sodium flow

Simulations of a transient stratified sodium experiment are carried out using a classic unsteady RANS model and the second-generation URANS model, STRUCT-ε. Turbulence modeling challenges and their implications to stratified flow prediction are discussed in the context of other sources of error. Input errors are discussed and addressed; discretization error is calculated to be less than 5% of the inlet velocity, for 80% of the domain; and remaining errors in temperature distributions are attributed to the turbulence model. Qualitative flow features from the simulations are presented and discussed. Compared to the experiment, the STRUCT-ε turbulence model provides a more physically accurate prediction of temperature and momentum mixing in key regions of the domain. Quantitative measures such as the L 2 norm of the temperature discrepancy demonstrate the improved performance of the STRUCT-ε approach. In conclusion, the magnitude of the temperature fluctuations is very well-predicted by the STRUCT-ε, while URANS overpredicts them by approximately 50%.

42 ENGINEERING↗

Design Optimization and Measurement Uncertainty of an Electromagnetic Level Sensor for Liquid Metal Reactors

Here, this article describes the design and operation of a prototype mutual inductance level sensor (MILS) and the development and validation of a finite-element analysis (FEA) model describing its behavior. The MILS was designed for use in liquid sodium up to temperatures of 650 °C in the Mechanisms Engineering Test Loop (METL) at Argonne National Laboratory (ANL). Preliminary testing was performed in a room temperature test stand with aluminum acting as an analog for the sodium to better understand sensor performance and provide accurate code validation data. This experimental data, along with material properties found in literature, were used to validate an FEA model in ANSYS Maxwell. The validated ANSYS Maxwell model was used to examine the performance of the MILS in various environments and under various operating conditions. Simulations suggest the following: The MILS will perform adequately in liquid sodium and liquid lead at temperatures up to 650 °C . The temperature dependence of electrical conductivity imposes a temperature dependence on the sensor that requires proper compensation. The MILS signal sensitivity is maximized when mutual inductance between sensor coils is maximized, and sensor geometry should be selected to account for this factor. The operating frequency of the MILS can be optimized and is dependent on process fluid material, operating temperature, and materials/geometry of sensor system. Finally, the use of a stainless-steel isolating thimble does not adversely affect the sensor signal. The primary sources of error for this MILS system are the accuracy of the calibration standard against which the sensor is calibrated, and the temperature dependence of the sensor. This work contains all the necessary details to recreate the FEA model and results. This model can be used to optimize the performance of a MILS in any operating environment to read any electrically conductive working fluid.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Performance of Al-Mn Transition-Edge Sensor Bolometers in SPT-3G

SPT-3G is a polarization-sensitive receiver, installed on the South Pole Telescope, that measures the anisotropy of the cosmic microwave background (CMB) from degree to arcminute scales. The receiver consists of ten 150-mm-diameter detector wafers, containing a total of similar to 16,000transition-edge sensor (TES) bolometers observing at 95, 150, and 220 GHz. During the 2018-2019 austral summer, one of these detector wafers was replaced by a new wafer fabricated with Al-Mn TESs instead of the Ti/Au design originally deployed for SPT-3G. We present the results of in-laboratory characterization and on-sky performance of this Al-Mn wafer, including electrical and thermal properties, optical efficiency measurements, and noise-equivalent temperature. In addition, we discuss and account for several calibration-related systematic errors that affect measurements made using frequency-domain multiplexing readout electronics.

Al-Mn↗

Model uncertainty in accelerator application simulations

Monte-Carlo nuclear reaction and transport codes are widely used to devise accelerator-based nuclear physics experiments; at the same time, many experiments are performed to validate the Monte-Carlo codes, which can be used for the design of full-scale nuclear power applications or the design of new benchmark experiments. Dedicated model benchmark studies investigate a broad range of nuclear reactions and quantities. Examples of these include isotope formation or secondary particle fluxes that result from the interactions of GeV-range hadrons with monoisotopic targets, which can be used to assess the respective systematic uncertainty of models. Such benchmark studies, as well as many nuclear application experiments and simulations carried out by various groups over the last few decades, enable us to draw methodological lessons. In this work, model uncertainty determined based on available experimental data allow us to identify the effects of practitioner expertise as well as the design of codes (user access to micro-scale parameters) on the range of uncertainties. We found that in cases when simulations are performed by code developers or users that are very experienced in performing simulations, the model to experiment quantity ratios generally agree with the limits determined by dedicated benchmark studies. In other cases, the ratios generally tend to be either smaller (underestimation of model error) or larger (overestimation of model error). A plausible explanation of the aforementioned effects is suggested.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

In Situ Ion Counting for Improved Implanted Ion Error Rate and Silicon Vacancy Yield Uncertainty

An in situ counted ion implantation experiment improving the error on the number of ions required to form a single optically active silicon vacancy (SiV) defect in diamond 7-fold compared to timed implantation is presented. Here, traditional timed implantation relies on a beam current measurement followed by implantation with a preset pulse duration. It is dominated by Poisson statistics, resulting in large errors for low ion numbers. Instead, our in situ detection, measuring the ion number arriving at the substrate, results in a 2-fold improvement of the error on the ion number required to generate a single SiV compared to timed implantation. Through postimplantation analysis, the error is improved 7-fold compared to timed implantation. SiVs are detected by photoluminescence spectroscopy, and the yield of 2.98% is calculated through the photoluminescence count rate. Hanbury–Brown–Twiss interferometry is performed on locations potentially hosting single-photon emitters, confirming that 82% of the locations exhibit single photon emission statistics.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Autonomous stabilization with programmable stabilized state

Reservoir engineering is a powerful technique to autonomously stabilize a quantum state. Traditional schemes involving multi-body states typically function for discrete entangled states. In this work, we enhance the stabilization capability to a continuous manifold of states with programmable stabilized state selection using multiple continuous tuning parameters. We experimentally achieve 84.6% and 82.5% stabilization fidelity for the odd and even-parity Bell states as two special points in the manifold. We also perform fast dissipative switching between these opposite parity states within 1.8 μs and 0.9 μs by sequentially applying different stabilization drives. Our result is a precursor for new reservoir engineering-based error correction schemes.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Quantum approximate optimization of the long-range Ising model with a trapped-ion quantum simulator

Quantum computers and simulators may offer significant advantages over their classical counterparts, providing insights into quantum many-body systems and possibly improving performance for solving exponentially hard problems, such as optimization and satisfiability. Here, we report the implementation of a low-depth Quantum Approximate Optimization Algorithm (QAOA) using an analog quantum simulator. We estimate the ground-state energy of the Transverse Field Ising Model with long-range interactions with tunable range, and we optimize the corresponding combinatorial classical problem by sampling the QAOA output with high-fidelity, single-shot, individual qubit measurements. We execute the algorithm with both an exhaustive search and closed-loop optimization of the variational parameters, approximating the ground-state energy with up to 40 trapped-ion qubits. We benchmark the experiment with bootstrapping heuristic methods scaling polynomially with the system size. We observe, in agreement with numerics, that the QAOA performance does not degrade significantly as we scale up the system size and that the runtime is approximately independent from the number of qubits. We finally give a comprehensive analysis of the errors occurring in our system, a crucial step in the path forward toward the application of the QAOA to more general problem instances.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗