SU-D-213-01: Transparent Photon Detector For The Online Monitoring Of IMRT Beams

Purpose: An innovative Transparent Detector for Radiotherapy (TraDeRa) has been developed. The detector aims at real-time monitoring of modulated beam ahead of the patient during delivery sessions, with a field cover up to 40×40 cm {sup 2}. Methods: TraDeRa consists in a pixelated matrix of ionization chambers with a patented electrodes design. An in-house designed specific integrated circuit allows to extract the signal and provides a real-time map of beam intensity and shape, at the linac pulse-scale. The measurements under irradiation are made with a 6 MV clinical X-Ray beam. Dose calculations are performed with the Monte Carlo code PENELOPE, modeling the full accelerator head and the TraDeRa detector. Results: A 2 % attenuation of the beam was measured in the presence of TraDeRa and the PENELOPE dosimetric study showed no significant modification of the photon beam properties. TraDeRa detects error leaf position as small as 1 mm compared to a reference field, for both static and modulated fields. In addition, measurements are accurate over a large dynamic range from low intensity signals, as inter-leaves leaks, to very high intensities as obtained on the medical line of the European Synchrotron Radiation Facility. The detector is fully operational for conventional and high dose rate beams as FFF modes (up to 2400 MU/min). Conclusion: The current version of TraDeRa shows promising results for IMRT quality assurance (QA), allowing pulse-scale monitoring of the beam and high sensitivity for errors detection. The attenuation is small enough not to hinder the irradiation while keeping the beam upstream of the patient under constant control. A final prototype under development will include 1600 independent electrodes, half of them with a high resolution centered on the beam axis. This compact detector provides an independent set of measurements for a better QA. Funding support : This work was supported by the LABEX PRIMES (ANR-11-LABX-0063) of Universite de Lyon, within the program “Investissements d’Avenir” (ANR-11-IDEX-0007) operated by the French National Research Agency (ANR) and within the project “INSPIRA” operated by the OSEO institution.

60 APPLIED LIFE SCIENCES↗

Gluon field digitization via group space decimation for quantum computers

Efficient digitization is required for quantum simulations of gauge theories. Schemes based on discrete subgroups use fewer qubits at the cost of systematic errors. We systematize this approach by deriving a single plaquette action for approximating general continuous gauge groups through integrating out field fluctuations. This provides insight into the effectiveness of these approximations, and how they could be improved. We accompany the scheme by simulations of pure gauge over the largest discrete subgroup of SU(3) up to the third order.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Use of Electronic Hand-held Devices for Collection of Savannah River Site Environmental Data - 13329

Savannah River Nuclear Solutions has begun using Xplore Tablet PC's to collect data in the field for soil samples, groundwater samples, air samples and round sheets at the Savannah River Site (SRS). EPA guidelines for groundwater sampling are incorporated into the application to ensure the sample technician follows the proper protocol. The sample technician is guided through the process for sampling and round sheet data collection by a series of menus and input boxes. Field measurements and well stabilization information are entered into the tablet for uploading into Environmental Restoration Data Management System (ERDMS). The process helps to eliminate input errors and provides data integrity. A soil sample technician has the ability to collect information about location of sample, field parameter, describe the soil sample, print bottle labels, and print chain of custody for the sample that they have collected. An air sample technician has the ability to provide flow, pressure, hours of operation, print bottle labels and chain of custody for samples they collect. Round sheets are collected using the information provided in the various procedures. The data are collected and uploaded into ERDMS. The equipment used is weather proof and hardened for the field use. Global Positioning System (GPS) capabilities are integrated into the applications to provide the location where samples were collected and to help sample technicians locate wells that are not visited often. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Geometrical picture of the electron–electron correlation at the large- D limit

In electronic structure calculations, the correlation energy is defined as the difference between the mean field and the exact solution of the non relativistic Schrödinger equation. Such an error in the different calculations is not directly observable as there is no simple quantum mechanical operator, apart from correlation functions, that correspond to such quantity. Here, we use the dimensional scaling approach, in which the electrons are localized at the large-dimensional scaled space, to describe a geometric picture of the electronic correlation. Both, the mean field, and the exact solutions at the large-D limit have distinct geometries. Thus, the difference might be used to describe the correlation effect. Moreover, correlations can be also described and quantified by the entanglement between the electrons, which is a strong correlation without a classical analog. Entanglement is directly observable and it is one of the most striking properties of quantum mechanics and bounded by the area law for local gapped Hamiltonians of interacting many-body systems. This study opens up the possibility of presenting a geometrical picture of the electron–electron correlations and might give a bound on the correlation energy. Furthermore, the results at the large-D limit and at D = 3 indicate the feasibility of using the geometrical picture to get a bound on the electron–electron correlations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A non-intrusive optical (NIO) approach to characterize heliostats in utility-scale power tower plants: Methodology and in-situ validation

No reliable in-situ optical characterization tool is available that can efficiently and accurately measure various optical errors of individual heliostats in a utility-scale power-tower plant. Here, an innovative non-intrusive optical (NIO) approach is proposed to measure mirror surface slope error, mirror facet canting error, and heliostat tracking error based on reflection images using the natural target—the tower—in a heliostat field. The NIO approach adopts various techniques in photogrammetry, reflectometry, and geometrical optics to first determine the camera position and the actual tower position with respect to the heliostat. Then, Snell’s law is applied to find the surface normal at the reflection point or line of a reflection image and derive the surface slope error, mirror facet canting error, and heliostat tracking error accordingly. In addition, an in-situ validation is performed to demonstrate the feasibility of the NIO approach. Analysis with multiple sets of reflection images on one single heliostat of interest demonstrates that the NIO method can achieve a measurement uncertainty of 0.22 mrad for mirror facet slope error (root-mean-square) at the given test conditions. The sensitivity of measurement uncertainty to various parameters will be presented in a separate work. In the future, state-of-the-art unmanned aerial systems (UAS) are planned to perform the efficient image collection with a goal to complete the survey across a utility-scale field of over 10,000 heliostats within one or a few days depending on the number of UASs. The development of the NIO approach is expected to fill the critical gap for successful solar-field operation and maintenance, which is necessary for the global growth of the solar power-tower technology. The NIO approach can also be applied to any relevant industry requiring high-precision mirror surface shape characterization.

14 SOLAR ENERGY↗

A Revolution in Mars Topography and Gravity and Magnetic Fields

Since the arrival of the Mars Global Surveyor (MGS) at Mars in September 1997 and the subsequent beginning of observations of the planet there has been a constant stream of surprises and puzzling observations that have kept scientists looking at new 'out of the box' explanations. Observations of the shape and topography have shown a planet with one hemisphere, the southern, several kilometers higher than the north and a northern hemisphere that is so flat and smooth in places that it's difficult to imagine it was not once the bottom of an ocean. And yet the ocean idea presents some enormous difficulties. The measurements of gravity derived from the tracking of MGS have shown that several Mars volcanoes are enormous positive gravity anomalies much larger than we see on Earth and revealed small errors in the orbit of Mars and or Earth. And the magnetic field is found to be composed of a number of extremely large crustal anomalies; but as far as can be ascertained there is no main dipole field such as we have on Earth. Understanding these diverse observations and placing them in the sequence of the evolution of the planet will be a long, challenging but rewarding task.

Smith, David E.↗

Beam correction for multi-pass arcs in FFA@CEBAF: status update

This work examines the multi-pass steering of six electron beams in an FFA arc ranging from approximately 10.5 GeV to 22 GeV. Shown here is an algorithm based on singular value decomposition (SVD) to successfully steer all six beams through the arc given precise knowledge of all beam positions at each of one hundred and one diagnostic locations with one hundred individual corrector magnets: that is successive application of SVD to different 100 × 101 response matrices—one for each beam energy. Further, a machine learning scheme is developed which only requires knowledge of the energy-averaged beam position at each location to provide equivalent steering. Extension of this scheme to other beam optics quantities as well as transverse and longitudinal coupling is explored.

Accelerator Physics↗

Manufactured solutions for an electromagnetic slot model

The accurate modeling of electromagnetic penetration is an important topic in computational electromagnetics. Electromagnetic penetration occurs through intentional or inadvertent openings in an otherwise closed electromagnetic scatterer, which prevent the contents from being fully shielded from external fields. To efficiently model electromagnetic penetration, aperture or slot models can be used with surface integral equations to solve Maxwell's equations. A necessary step towards establishing the credibility of these models is to assess the correctness of the implementation of the underlying numerical methods through code verification. Surface integral equations and slot models yield multiple interacting sources of numerical error and other challenges, which render traditional code-verification approaches ineffective. In this paper, we provide approaches to separately measure the numerical errors arising from these different error sources for the method-of-moments implementation of the electric-field integral equation with a slot model. Finally, we demonstrate the effectiveness of these approaches for a variety of cases.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

FInd Gas Source

FIGS is a neural network software that ingests real time synchronized field data on environmental flow fields and turbulence and gas concentration variations at high frequency and uses an error minimization algorithm to locate the gas source and quantify its strength. The software can be interfaced with atmospheric, oceanic and subsurface instruments in a variety of platforms stationary or mobile (e.g. cars, UAVs, submersible vehicles or boreholes) and used to find gas sources by smart use of data and phenomenology. FIGS can be trained by phenomenological model of the flow fields in the environment of interest and/or be calibrated by controlled release. After initial deployment the FIGS learning will grow with time as it accumulates data on source quantification. FIGS can be installed on any computer from small beagle-bones for field deployment/end-use to PC/MACs/main-frame for training/analysis. FIGS has been trained (using LANL's high resolution atmospheric simulations) and calibrated, tested and evaluated in the field and shown to perform well in finding and quantifying methane leaks at 10-100m scales at well pads by ingesting atmospheric measurements. The code is applicable to gas and particle source location at large scales.

Travis, Bryan↗

Mariner 9 celestial mechanics experiment - Gravity field and pole direction of Mars.

Analysis of the Mariner 9 radio-tracking data shows that the Martian gravity field is rougher than that of earth or the moon, and that the accepted direction of the Mars rotation axis is in error by about 0.5 deg. Contours of equivalent surface heights deduced from a sixth-degree solution for the Martian gravity field are presented. These contours represent the deviations from sphericity of a uniformly dense body with an external potential which is given by the first sixth-degree solution. In addition to Doppler observations, ranging or group-delay measurements have been made regularly since orbit insertion.

Lorell, J.↗

A Monte Carlo Based Ray Tracing Tool for Evaluating Wolter-Type Prescriptions

Evaluating Wolter-like X-ray mirror prescriptions via ray tracing is useful for selecting and optimizing the right mirror prescriptions for a specified application. Moreover, incorporating real metrology data into a ray trace and simulating point spread functions (PSF) allows for performance predictions representative of real manufacturing errors and tolerances. In fulfillment of an internship project, an X-ray ray trace routine using a Monte-Carlo method has been developed to examine different Wolter-like prescriptions and characterize their theoretical performances over a specified field of view. This routine includes the ability to use real metrology data to evaluate the impact of figure error on imaging performance. As a test case, the Marshall Grazing Incidence X-ray Spectrometer (MaGIXS) Wolter-I mirror prescription and an equivalent Wolter-Schwarzschild prescription were traced and imaging performance of a specified field of view were mapped. Here we present the approach used in this routine, showcase example results, and discuss future goals for expanding the routine to address azimuthally varying figure errors and surface roughness.

X-ray optics↗

Interlaboratory Study of Digital Volume Correlation Error Due to X-Ray Computed Tomography Equipment and Scan Parameters: an Update from the DVC Challenge

Background: The quality of Digital Volume Correlation (DVC) full-field displacement measurements depends directly on the characteristics of the X-ray Computed Tomography (XCT) equipment, and scan procedures used to acquire the tomographic images. Objective: In this work, we seek to experimentally study the effects of XCT equipment and tomographic scan procedures on the quality of these images for DVC analysis, and to survey the level of DVC error that may be achieved using standard XCT operating procedures. Methods: Six participants in an interlaboratory study acquired high-quality XCT scans of a syntactic foam before and after rigid body motion. The resulting images were correlated using commercial DVC software to quantify error sources due to random image noise, reconstruction artifacts, as well as systematic spatial or temporal distortion. Results: In the absence of rigid body motion, the standard deviation of the displacement measurements ranged from 0.012 to 0.043 voxels using a moderate subvolume size, indicating that subvoxel measurement resolution could readily be achieved with a variety of XCT equipment and scan recipes. Comparison of consecutive scans without rigid body motion showed transient dilatational displacement gradients due to self-heating of the X-ray source and/or thermal expansion of the foam. Evaluation of the scans after rigid body motion showed significant, machine-specific spatial distortion in the displacement fields of up to 0.5 voxels; new approaches to remove this error need to be developed. Conclusions: Analysis of the scan protocols used in the interlaboratory study, as well as a complementary parametric sensitivity study, showed that the DVC error was strongly influenced by the XCT equipment, but could be mitigated by adjusting the total scan duration.

47 OTHER INSTRUMENTATION↗

SIM spectral characteristics and accuracy analysis

The Space Interferometry Mission (SIM) will perform global astrometry (full sky), local wide-angle (15 degree) and narrow-angle (1 degree) observations to search extra-solar planets, and can calibrate stellar and galactic evolution theories. The astrometric accuracy of the SIM mission depends on spectral characteristics of the optics, detectors and targets. This paper will discuss the photometric throughput of the SIM instrument, and analyze effects of wavefront errors, optical mismatches and control biases as a function of wavelength. The color dependence models of the instrument optics including mirrors, lenses, field-stop and beam-splitter are presented. The performances of different detectors with a variety of coatings are compared. A model of the SIM fringe spectrometer is created. For early and late types of stars, brightness dependency errors are analyzed for different combinations of optics and detectors. Visibility loss due to imperfect optics is investigated in detail. Based on the models of instrument and estimated visibilities, the astrometric accuracies for various kinds of stars are evaluated. It is important to emphasize that not only light sources, mirrors, lenses, field stop and detectors are all wavelength dependent, but also fringe visibility loss, wavefront error, optics control error, etc. are all a function of wavelengths. For the first time the estimate of SIM performance is based on spectral analysis of all factors above, rather than monochromatic approximations of detected fringes, or simply adopted constants. This paper summarizes the astrometric accuracies for a wide range of stars and various combinations of optical design and detector configurations. It has been verified that SIM has astrometric accuracy of about 4 μas for targets with different spectra.

Shao, Michael↗

Towards sharp error analysis of extended Lagrangian molecular dynamics

The extended Lagrangian molecular dynamics (XLMD) method provides a useful framework for reducing the computational cost of a class of molecular dynamics simulations with constrained latent variables. The XLMD method relaxes the constraints by introducing a fictitious mass ε for the latent variables and solving a set of singularly perturbed ordinary differential equations. While favorable numerical performance of XLMD has been demonstrated in several different contexts in the past decade, mathematical analysis of the method remains scarce. Here, we propose the first error analysis of the XLMD method in the context of a classical polarizable force field model. While the dynamics with respect to the atomic degrees of freedom are general and nonlinear, the key mathematical simplification of the polarizable force field model is that the constraints on the latent variables are given by a linear system of equations. We prove that when the initial value of the latent variables is compatible in a sense that we define, XLMD converges as the fictitious mass ε is made small with $\mathscr{O}$(ε) error for the atomic degrees of freedom and with $\mathscr{O}$($\sqrt{ε}$) error for the latent variables, when the dimension of the latent variable d' is 1. Furthermore, when the initial value of the latent variables is improved to be optimally compatible in a certain sense, we prove that the convergence rate can be improved to $\mathscr{O}$(ε) for the latent variables as well. Numerical results verify that both estimates are sharp not only for d'=1, but also for arbitrary d'. In the setting of general d', we do obtain convergence, but with the non-sharp rate of $\mathscr{O}$($\sqrt{ε}$) for both the atomic and latent variables.

74 ATOMIC AND MOLECULAR PHYSICS↗

Evaluation of lens distortion errors in video-based motion analysis

In an effort to study lens distortion errors, a grid of points of known dimensions was constructed and videotaped using a standard and a wide-angle lens. Recorded images were played back on a VCR and stored on a personal computer. Using these stored images, two experiments were conducted. Errors were calculated as the difference in distance from the known coordinates of the points to the calculated coordinates. The purposes of this project were as follows: (1) to develop the methodology to evaluate errors introduced by lens distortion; (2) to quantify and compare errors introduced by use of both a 'standard' and a wide-angle lens; (3) to investigate techniques to minimize lens-induced errors; and (4) to determine the most effective use of calibration points when using a wide-angle lens with a significant amount of distortion. It was seen that when using a wide-angle lens, errors from lens distortion could be as high as 10 percent of the size of the entire field of view. Even with a standard lens, there was a small amount of lens distortion. It was also found that the choice of calibration points influenced the lens distortion error. By properly selecting the calibration points and avoidance of the outermost regions of a wide-angle lens, the error from lens distortion can be kept below approximately 0.5 percent with a standard lens and 1.5 percent with a wide-angle lens.

Poliner, Jeffrey↗

Structure of the Wall Sheath in a Gas-Discharge Plasma for an Arbitrary Orientation of a Flat Probe Relative to the Electric Field in the Plasma

We investigate the structure of the wall sheath of a gas discharge near a flat surface at a negative potential for high mean electron energy. It is shown that in the conditions where the mean energy of ions in the plasma is much lower than the mean electron energy, the parameters of the wall sheath weakly depend on the mutual orientation of the normal to the surface and the electric field in the plasma for an arbitrary ratio of the Debye radius to the ion mean free path relative to the resonant charge exchange process. It is found that for inert gases (He, Ar) for ratio E/P of the electric field to pressure exceeding 10 V/(cm Torr) in the plasma, the disregard of ionization in the perturbed wall sheath can lead to substantial errors in the calculation of its parameters. It is shown that the ionization leads to an increase in the electric field in the wall sheath and, as a consequence, to an increase in the mean velocity of ions at the boundary between the quasi-neutral presheath and the part of the perturbed wall sheath in which quasi-neutrality is substantially violated. The parameters of the wall sheath where quasi-neutrality is significantly violated depend on the ionization rate much less strongly than the corresponding parameters of the quasi-neutral presheath. We have determined the relation for concentration of charged particles in the unperturbed plasma from the ion saturation current considering the actual ion energy distribution function in the plasma as well as ionization in the presheath and the part of the perturbed wall sheath in which quasi-neutrality is violated significantly.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Heliostat Consortium: Gap Analysis on Wind Load for Achieving a Fully Competitive Heliostat Industry

The Heliostat Consortium (HelioCon) Wind Load Subtask was initiated with the aim of bringing research work pertaining to wind load measurement, characterization, and prediction taking place across several tasks, including Advanced Manufacturing, Components and Controls, and Field Deployment. The cross-cutting wind load subtopic in the HelioCon roadmap report [1] highlighted standardized methods and tools that are needed for a more detailed understanding of the static and dynamic loads on a heliostat. This will enable cost reduction of wind-dependent heliostat components to avoid unnecessarily conservative, overly constrained designs and increase field efficiency/reliability, to reduce the risk of component failures due to high-wind events (>15 m/s). Gaps related to heliostat wind load include site characterization for wind measurements, critical load cases for heliostat design, turbulence impacts on heliostat tracking error, testing of heliostat array configurations, understanding spatial variation of maximum loads across the solar field, and heliostat field layout and operating strategies. The recommended highest-priority pathway as first steps taken by HelioCon to address these gaps are to develop site characterization guidelines for heliostat design and field load measurements.

Emes, Matthew (ORCID:0000000341474387)↗

Comparison of Precision of Biomass Estimates in Regional Field Sample Surveys and Airborne LiDAR-Assisted Surveys in Hedmark County, Norway

Airborne scanning LiDAR (Light Detection and Ranging) has emerged as a promising tool to provide auxiliary data for sample surveys aiming at estimation of above-ground tree biomass (AGB), with potential applications in REDD forest monitoring. For larger geographical regions such as counties, states or nations, it is not feasible to collect airborne LiDAR data continuously ("wall-to-wall") over the entire area of interest. Two-stage cluster survey designs have therefore been demonstrated by which LiDAR data are collected along selected individual flight-lines treated as clusters and with ground plots sampled along these LiDAR swaths. Recently, analytical AGB estimators and associated variance estimators that quantify the sampling variability have been proposed. Empirical studies employing these estimators have shown a seemingly equal or even larger uncertainty of the AGB estimates obtained with extensive use of LiDAR data to support the estimation as compared to pure field-based estimates employing estimators appropriate under simple random sampling (SRS). However, comparison of uncertainty estimates under SRS and sophisticated two-stage designs is complicated by large differences in the designs and assumptions. In this study, probability-based principles to estimation and inference were followed. We assumed designs of a field sample and a LiDAR-assisted survey of Hedmark County (HC) (27,390 km2), Norway, considered to be more comparable than those assumed in previous studies. The field sample consisted of 659 systematically distributed National Forest Inventory (NFI) plots and the airborne scanning LiDAR data were collected along 53 parallel flight-lines flown over the NFI plots. We compared AGB estimates based on the field survey only assuming SRS against corresponding estimates assuming two-phase (double) sampling with LiDAR and employing model-assisted estimators. We also compared AGB estimates based on the field survey only assuming two-stage sampling (the NFI plots being grouped in clusters) against corresponding estimates assuming two-stage sampling with the LiDAR and employing model-assisted estimators. For each of the two comparisons, the standard errors of the AGB estimates were consistently lower for the LiDAR-assisted designs. The overall reduction of the standard errors in the LiDAR-assisted estimation was around 40-60% compared to the pure field survey. We conclude that the previously proposed two-stage model-assisted estimators are inappropriate for surveys with unequal lengths of the LiDAR flight-lines and new estimators are needed. Some options for design of LiDAR-assisted sample surveys under REDD are also discussed, which capitalize on the flexibility offered when the field survey is designed as an integrated part of the overall survey design as opposed to previous LiDAR-assisted sample surveys in the boreal and temperate zones which have been restricted by the current design of an existing NFI.

Comparison↗