Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “error detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,351 records · Page 75

Differential correction technique for removing common errors in gas filter radiometer measurements

The Measurement of Air Pollution from Satellites (MAPS) gas filter radiometer experiment was designed to measure CO mixing ratios in the earth's atmosphere. MAPS also measures N2O to provide a reference channel for the atmospheric emitting temperature and to detect the presence of clouds. In this paper we formulate equations to correct the radiometric signals based on the spatial and temporal uniformity of the N2O mixing ratio in the atmosphere. Results of an error study demonstrate that these equations reduce the error in inferred CO mixing ratios. Subsequent application of the technique to the MAPS 1984 data set decreases the error in the frequency distribution of mixing ratios and increases the number of usable data points.

Wallio, H. A.↗

Refined Telluric Absorption Correction for Low-resolution Ground-based Spectroscopy: Resolution and Radial Velocity Effects in the O{sub 2}A-band for Exoplanets and K i Emission Lines

Telluric correction of spectroscopic observations is either performed via standard stars that are observed close in time and airmass along with the science target, or recently growing in importance, by theoretical telluric absorption modeling. Both approaches work fine when the telluric lines are resolved, i.e., at a spectral resolving power larger than about 10,000, and it is sufficient to facilitate the detection of spectral features at lower resolution. However, a meaningful quantitative analysis also requires the reliable recovery of line strengths. Here, we show for the Fraunhofer A-band of molecular O{sub 2} that the standard telluric correction approach fails in this at lower spectral resolutions, as an example for the general problem. Doppler-shift-dependent errors of the restored flux may arise, which can amount to more than 50% in extreme cases, depending on the line shapes of the target spectral features. Two applications are discussed: the recovery of the O{sub 2} band in the reflected light of an Earth analog atmosphere, as facilitated potentially in the future using an orbiting starshade and a ground-based extremely large telescope; and the recovery of the intrinsic ratio of the K i lines in the post-nova V4332 Sgr tracing the optical depth of the emitting region, to exemplify the relevance using present-day instrumentation. We show how one should derive correction functions for the compensation of the error in dependence of radial velocity shift, spectral resolution, and target line-profile function by use of high-resolution atmospheric transmission modeling, which has to be solved for the individual case.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Anomaly Detection in Sequential Health Care Data using Higher-Order Network Representation

The ever-increasing use of information technology (IT) in health care presents new challenges to patient care. Information errors arising from the use of Health IT and their implications on care delivery and patient outcomes have been widely reported. Information errors can lead to changes in clinical decisions, care processes, and care outcomes, among others. An altered care process, for example, could interrupt the sequence of care, which could lead to changes in care decisions and/or changes in care outcomes. We define interruptions in the care process as anomalies in the care sequence. In this paper, we present a new approach based on the higher-order network (HON) representation to detect anomalies in sequential health care data using electronic health records. The results show that there are higher-order dependencies in health care data; and that the use of HON representation is more effective than the first-order network representation for detecting anomalies in sequential health care data.

Niu, Haoran↗

X-ray emission from gamma-ray sources in the galactic anticentre region

An X-ray survey of three high energy gamma-ray sources in the galactic anticenter region conducted using the large area sky survey instrument on HEAO 1 is presented. The sensitivity of this survey is highest reported, and two, and possibly three, X-ray sources were detected in the vicinity of gamma 195+5. Three new X-ray sources have been discovered within a few degrees of CG176-7, but none overlaps the gamma-ray error box. These results demonstrate that gamma-ray sources like CG195+4 and CG176-7 have emission characteristics different from the Crab pulsar, but may be similar to the Vela pulsar. Alternatively, the lack of detectable X-ray flux suggests that the gamma-ray emission arises from cosmic-ray interactions in dense interstellar clouds. An interesting feature of the new X-ray sources is that four of them may be associated with early-type stars which exhibit emission lines.

Share, G. H.↗

Application of the Pseudo Wigner-Ville Distribution to the Measurement of the Dispersion of Lamb Modes in Graphite/Epoxy Plates

Acoustic waves propagate in thin plates as guided or Lamb modes. The velocities of these modes are dispersive in that they depend not only on the material elastic properties and density, but also on the frequency. Accurate characterization of Lamb wave dispersion is important in many acoustic based nondestructive evaluation techniques. It is necessary for ultrasonic measurements in thin plates to determine elastic properties and for flaw detection and localization. In acoustic emission (AE) testing, if not taken into account, highly dispersive Lamb mode propagation can lead to large errors in source location. In this study, the pseudo Wigner-Ville distribution (PWVD) was used for measurement of group velocity dispersion of Lamb waves in a unidirectional graphite/epoxy (AS4/3502) laminate. The PWVD is one of a number of transforms which provide a time-frequency representation of a digitized time series. Broad band acoustic waves were generated by a pencil lead fracture (Hsu-Neilsen source) and were detected with broad band ultrasonic transducers. The arrival times for the lowest order symmetric (S(sub 0)) and antisymmetric (A(sub 0)) Lamb modes were determined from measurements of the time at which the respective peak amplitudes occurred in the PWVD. Measurements were made at several source-to-detector distances and a least squares fit used to calculate the velocity. Results are presented for propagation along, and perpendicular to, the fiber direction. Theoretical dispersion curves were also calculated and a comparison between theory and experiment demonstrates good agreement.

Prosser, W. H.↗

A monitor for the laboratory evaluation of control integrity in digital control systems operating in harsh electromagnetic environments

This paper presents a strategy for dynamically monitoring digital controllers in the laboratory for susceptibility to electromagnetic disturbances that compromise control integrity. The integrity of digital control systems operating in harsh electromagnetic environments can be compromised by upsets caused by induced transient electrical signals. Digital system upset is a functional error mode that involves no component damage, can occur simultaneously in all channels of a redundant control computer, and is software dependent. The motivation for this work is the need to develop tools and techniques that can be used in the laboratory to validate and/or certify critical aircraft controllers operating in electromagnetically adverse environments that result from lightning, high-intensity radiated fields (HIRF), and nuclear electromagnetic pulses (NEMP). The detection strategy presented in this paper provides dynamic monitoring of a given control computer for degraded functional integrity resulting from redundancy management errors, control calculation errors, and control correctness/effectiveness errors. In particular, this paper discusses the use of Kalman filtering, data fusion, and statistical decision theory in monitoring a given digital controller for control calculation errors.

Belcastro, Celeste M.↗

A Diagnostic Analysis of the Kennedy Space Center LDAR Network 2. Cross-Sensor Studies

Range dependencies in total (intracloud and cloud to ground) lightning observed by the Kennedy Space Center Lightning Detection and Ranging (LDAR) network are established through cross comparison with other lightning sensors. Using total lightning observed from space by the Lightning Imaging Sensor (LIS), MAR flash detection efficiency is shown to remain above 90% out to 90-100 km range, and to be below 25% at 200 km range. MAR VHF source location error distributions are also determined as a function of range and are found to be asymmetric with standard deviation increasing roughly as r 2 . Range normalization schemes for total VHF source density are tested and shown to yield significant improvements in correlation with National Lightning Detection Network (NLDN) ground flash density at hourly, daily, monthly, and climatological timescales (up to 50% over uncorrected source densities using an exponential-in-range correction factor with 40-50 km e-folding scale).

Boccippio, D. J.↗

The Third EGRET Catalog of High-Energy Gamma-Ray Sources

The third catalog of high-energy gamma-ray sources detected by the EGRET telescope on the Compton Gamma Ray Observatory includes data from 1991 April 22 to 1995 October 3 (Cycles 1, 2, 3, and 4 of the mission). In addition to including more data than the second EGRET catalog and its supplement, this catalog uses completely reprocessed data (to correct a number of mostly minimal errors and problems). The 271 sources (E greater than 100 MeV) in the catalog include the single 1991 solar flare bright enough to be detected as a source, the Large Magellanic Cloud, five pulsars, one probable radio galaxy detection (Cen A), and 66 high-confidence identifications of blazars (BL Lac objects, flat-spectrum radio quasars, or unidentified flat-spectrum radio sources). In addition, 27 lower-confidence potential blazar identifications are noted. Finally, the catalog contains 170 sources not yet identified firmly with known objects, although potential identifications have been suggested for a number of those. A figure is presented that gives approximate upper limits for gamma-ray sources at any point in the sky, as well as information about sources listed in the second catalog and its supplement which do not appear in this catalog.

Hartman, R. C.↗

DESI and DECaLS (D&D): galaxy–galaxy lensing measurements with 1 per cent survey and its forecast

The shear measurement from the Dark Energy Camera Legacy Survey (DECaLS) provides an excellent opportunity for galaxy–galaxy lensing study with the Dark Energy Spectroscopic Instrument (DESI) galaxies, given the large (~9000 deg 2 ) sky overlap. We explore this potential by combining the DESI 1 per cent survey and DECaLS Data Release 8 (DR8). With ~106 deg 2 sky overlap, we achieve significant detection of galaxy–galaxy lensing for Bright Galaxy Survey (BGS) and luminous red galaxy (LRG) as lenses. Scaled to the full BGS sample, we expect the statistical errors to improve from 18(12)per cent to a promising level of 2(1.3)per cent at θ > 8arcmin(< 8 arcmin) ⁠. This brings stronger requirements for future systematics control. To fully realize such potential, we need to control the residual multiplicative shear bias |m| < 0.006 and the bias in the mean redshift |Δz| < 0.008, requiring the introduced bias in the measurement is <0.31σ. We also expect significant detection of galaxy–galaxy lensing with DESI LRG/emission line galaxy (ELG) full samples as lenses, and cosmic magnification of ELG through cross-correlation with low-redshift DECaLS shear. If such systematical error control can be achieved, we find the advantages of DECaLS, comparing with the Kilo Degree Survey (KiDS) and the Hyper Suprime-Cam (HSC), are at low redshift, large scale, and in measuring the shear ratio (to σ R ~ 0.04) and cosmic magnification.

(cosmology:) large-scale structure of Universe↗

A near-optimum receiver structure for the detection of M-ary optical PPM signals

A class of receivers called conditionally nulling receivers is defined for quantum noise limited optical communications. These receivers have the ability to decide at each moment in time whether or not to coherently combine a predetermined local oscillator field with the received optical field, prior to performing an energy measurement (photodetection) on the combined field. Conditionally nulling receivers are applicable to pulse position modulation and related modulation schemes, which have the property that, at each moment in time, the transmitted signal is in one of only two states, on or off. The local oscillator field which may or may not be added by the receiver is an exact replica of the negative of the received on field; hence, the receiver can exactly null the on signal if the on signal is present and the receiver chooses to use the local field. An ideal conditionally nulling receiver achieves very nearly the same error probability (within a multiplicative factor varying froom 1 to 2.15) as the optimum quantum measurement for quantum noise limited detection of M-ary PPM signals. In contrast, other known receiving methods, such as direct, heterodyne, and homodyne detection, are exponentially suboptimum.

Dolinar, S. J., Jr.↗

A second catalog of gamma ray bursts: 1978 - 1980 localizations from the interplanetary network

Eighty-two gamma ray bursts were detected between 1978 September 14 and 1980 February 13 by the experiments of the interplanetary network (Prognoz 7, Venera 11 and 12 SIGNE experiments, Pioneer Venus Orbiter, International Sun-Earth Explorer 3, Helios 2, and Vela). Sixty-five of these events have been localized to annuli or error boxes by the method of arrival time analysis. The distribution of sources is consistent with isotropy, and there is no statistically convincing evidence for the detection of more than one burst from any source position. The localizations are compared with those of two previous catalogs.

Atteia, J. L.↗

A Chip-Scale Oscillation-Mode Optomechanical Inertial Sensor Near the Thermodynamical Limits

Modern navigation systems integrate the global positioning system (GPS) with an inertial navigation system (INS), which complement each other for correct attitude and velocity determination. Here, the core of the INS integrates accelerometers and gyroscopes used to measure forces and angular rate in the vehicular inertial reference frame. With the help of gyroscopes and by integrating the acceleration to compute velocity and distance, precision and compact accelerometers with sufficient accuracy can provide small–error location determination. Solid–state implementations, through coherent readout, can provide a platform for high performance acceleration detection. In contrast to prior accelerometers using piezoelectric or capacitive readout techniques, optical readout provides narrow–linewidth high–sensitivity laser detection along with low–noise resonant optomechanical transduction near the thermodynamical limits. Here an optomechanical inertial sensor with an 8.2 µg Hz –1/2 velocity random walk (VRW) at an acquisition rate of 100 Hz and 50.9 µg bias instability is demonstrated, suitable for applications, such as, inertial navigation, inclination sensing, platform stabilization, and/or wearable device motion detection. Driven into optomechanical sustained–oscillation, the slot photonic crystal cavity provides radio–frequency readout of the optically–driven transduction with an enhanced 625 µg Hz –1 sensitivity. Measuring the optomechanically–stiffened oscillation shift, instead of the optical transmission shift, provides a 220× VRW enhancement over pre–oscillation mode detection.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Exploring 2D X-ray diffraction phase fraction analysis with convolutional neural networks: Insights from kinematic-diffraction simulations

Abstract Deep-learning models are effective for analyzing the complex information in 2D X-ray diffraction (XRD) patterns. Accurately collecting parameters of the material sample is crucial during model training, significantly impacting model performance. In this study, we employ a kinematic-diffraction simulator to generate simulated 2D XRD patterns for Ti–6Al–4V alloy, allowing precise control of sample parameters. These simulated patterns are used to train convolutional neural networks, predicting $$\upbeta$$ β -phase volume fractions. The training data set consists exclusively of 2D XRD patterns with pure $$\upalpha$$ α - or pure $$\upbeta$$ β -phase, while the testing set incorporates patterns with intermediate phase volume fraction. In particular, we investigate how the architectures of the model influence prediction reliability and computational performance. Experimental results reveal that, with appropriate training, the convolutional neural network accurately detects intermediate phase volume fractions even trained with only pure-phase patterns, achieving a mean square error accuracy of $$9.4 \times 10^{-4}$$ 9.4 × 10 - 4 . Graphical abstract

Yue, Weiqi↗

Multipath performance of a TDRS system employing wideband FM VHF signals

An approximate theoretical analysis is presented for the effects of specular reflection multipath on the performance of a one-way tracking and data relay satellite-to-user link. The analysis pertains to the wideband FM system employing a sinusoidal subcarrier to achieve spectrum spreading. Bounds on multipath effects are derived for receivers with and without limiters and for data modulated on the carrier or the subcarrier. For data modulation, performance is evaluated in terms of an additive lowpass signal at the data detection filter. Doppler and range tracking performance is evaluated in terms of root-mean-square (RMS) error of carrier frequency in a carrier PLL and rms phase jitter in a subcarrier PLL.

Sohn, S. J.↗

Relativistic astrophysics

The design, experimental testing, and calibration (error analysis) of a high resolution Cerenkov-scintillation detector is presented. The detector is capable of detecting iron isotopes and heavy ions of cosmic rays, and of performing direct measurements of individual neighboring isotopes at charge resolution 26. It utilizes Lexan (trademark) sheets, and has been used in flight packages of balloons and on the Skylab. The detector will be able to provide more information on violet astrophysical processes, such as thermonuclear reactions on neutron stars. Ground support and display equipment which are to be used in conjunction with the detector are also discussed.

Price, P. B.↗