Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “electrical measurements”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,351 records · Page 75

Middle atmospheric electrodynamics

A review is presented of the advances made during the last few years with respect to the study of the electrodynamics in the earth's middle atmosphere. In a report of the experimental work conducted, attention is given to large middle atmospheric electric fields, the downward coupling of high altitude processes into the middle atmosphere, and upward coupling of tropospheric processes into the middle atmosphere. It is pointed out that new developments in tethered balloons and superpressure balloons should greatly increase the measurement duration of earth-ionospheric potential measurements and of stratospheric electric field measurements in the next few years. Theoretical work considered provides an excellent starting point for study of upward coupling of transient and dc electric fields. Hays and Roble (1979) were the first to construct a model which included orographic features as well as the classical thunderstorm generator.

Kelley, M. C.↗

Photoconductivity of high voltage space insulating materials: Measurements with metal electrodes

The electrical conductivities of high voltage insulating materials were measured in the dark and under various intensities of illumination. The materials investigated included FEP Teflon, Kapton-H, fused quartz, and parylene. Conductivities were determined as functions of temperature between 22 and 100 C and light intensity between 0 and 2.5 kW/m2. The thickness dependence of the conductivity was determined for Teflon and Kapton, and the influence of spectral wavelengths on the conductivity was determined in several cases. All measurements were made in a vacuum to simulate a space environment, and all samples had metallic electrodes. The conductivity of Kapton was permanently increased by exposure to light; changes as great as five orders of magnitude were observed after six hours of illumination.

Coffey, H. T.↗

Measuring Work Functions Of "Dirty" Surfaces With A Vibrating Capacitive Probe

Apparatus measures work function of possibly contaminated surface of specimen of metal or other electrically conductive material. Measures work function of specimen indirectly, by vibrating capacitive measurement of contact potential. Work function of specimen affected by microstructure and by contamination.

Yost, William T.↗

Electric field distribution in a non-self-sustained RF discharge with ionization generated by Ns discharge pulses

Abstract Electric field in a capacitively coupled, non-self-sustained RF discharge nitrogen plasma with external ionization generated by high-voltage ns pulses has been measured by ps Electric field induced second harmonic generation (EFISH). The measurements are made both in the bulk of the plasma and in the sheaths, using the absolute calibration by the Laplacian field between two plane electrodes. The results are compared with the kinetic modeling calculations. The RF electric field in the sheaths is significantly higher compared to that in the plasma, due to the displacement of the electrons by the drift oscillations and the resultant plasma self-shielding. However, the kinetic modeling predictions indicate that the electron impact ionization in the sheaths is largely ineffective, due to the low electron density. The reduction of the electric field in the plasma by the self-shielding in the sheaths is moderate, such that the energy is coupled to the plasma by the below-breakdown RF field. The peak RF field in the plasma is in the range of 15–25 Td, indicating the efficient vibrational excitation of N 2 by electron impact. The modeling predictions suggest that the targeted vibrational excitation of molecular species in a non-self-sustained RF discharge with external ionization is scalable to high pressures, electron densities, and discharge powers. The present approach can be extended to the vibrational excitation of other molecular species where the vibrational relaxation is relatively slow, such as CO, CO 2 , and H 2 .

Physics↗

Evaluation of the rheological and electrical percolation of high‐density polyethylene/carbon black composites using mathematical models

Abstract In this work, conductive polymer composites (CPCs) of bio‐based polyethylene (BioPe) containing different concentrations of carbon black (CB) were developed. By using oscillatory rheology analysis, a Newtonian plateau was observed in BioPe, and all BioPe/CB composites had a behavior of a pseudo‐solid and that composites with volume fractions ranging from 0.24 to 0.56 presented higher viscosity, storage, and loss modulus. This suggests the formation of a percolated network and by using the power‐law models, it was observed that the electrical percolation threshold was higher than the rheological percolation threshold. The electrical conductivity was measured using the four‐point probe method and a sigmoid model was used to predict the CPCs' electrical conductivity percolation threshold. The results indicated that the four‐point probe method presented satisfactory results according to the calculated standard deviations and voltage–current characteristics for each round of measurements considering the same ranging as used in rheology analysis. The analytical model used showed a coefficient of determination ( R 2 ) higher than 95%, allowing the prediction of the electrical conductivity of the CPC and the percolation threshold as a function of the volumetric fraction of the CB.

da SiIva, Moacy P.↗

Remotely powered line monitor

Improved devices, apparatuses, systems, and methods involving the use of field probes with voltage-controlled variable impedance elements and surface-launched acoustic wave devices, including surface acoustic wave (SAW) devices and SAW sensor-tag wireless interface devices to measure voltage and current in current carrying conductors (CCCs) via measurement of the electric fields and magnetic fields around said CCCs are disclosed. The devices, apparatuses, systems, and methods taught in the present invention include a remotely powered line-mounted measurement unit that requires no connection to electrical ground for operation, and that has no internal energy source, no energy harvesting or power conditioning circuitry, no discrete energy storage components, and no radio. The devices, apparatuses, systems, and methods taught in the present invention also provide for determining the phase (leading or lagging) of the current relative to the voltage in AC power systems, and also provide for measurement of temperature of the conductor.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Detailed Uncertainty Analysis of the ZEM-3 Measurement System

The measurement of Seebeck coefficient and electrical resistivity are critical to the investigation of all thermoelectric systems. Therefore, it stands that the measurement uncertainty must be well understood to report ZT values which are accurate and trustworthy. A detailed uncertainty analysis of the ZEM-3 measurement system has been performed. The uncertainty analysis calculates error in the electrical resistivity measurement as a result of sample geometry tolerance, probe geometry tolerance, statistical error, and multi-meter uncertainty. The uncertainty on Seebeck coefficient includes probe wire correction factors, statistical error, multi-meter uncertainty, and most importantly the cold-finger effect. The cold-finger effect plagues all potentiometric (four-probe) Seebeck measurement systems, as heat parasitically transfers through thermocouple probes. The effect leads to an asymmetric over-estimation of the Seebeck coefficient. A thermal finite element analysis allows for quantification of the phenomenon, and provides an estimate on the uncertainty of the Seebeck coefficient. The thermoelectric power factor has been found to have an uncertainty of +9-14 at high temperature and 9 near room temperature.

Seebeck effect↗

Optical and electrical properties of proton-implanted p -GaSb for electrical isolation

The effect of proton implantation as isolation implant and subsequent annealing on the optical absorption and electrical resistivity of low-bandgap p -GaSb is reported. The measured transmittance spectra indicates that implantation creates a distribution of energy levels extending into the bandgap. Electrical measurements show that the average sheet resistance of the implanted layer increases only by an order of magnitude from its pre-implantation value at a proton dose of ~10 13 cm -2 followed by 200 °C annealing. It is also shown that annealing reduces the implantation-induced optical absorption while still retaining a high electrical resistivity.

42 ENGINEERING↗

Turbulence measurements in the compressor exit flow of a General Electric CF6-50 engine

Ruggedized cooled film probes were used to measure CF6-50 compressor exit turbulence properties at three different engine idle condition test points. The turbulence probe was coupled to a constant temperature anemometer and signal conditioning system. An on-line readout system connected to the anemometer was used to check the data as it was acquired. At engine idle conditions, the turbulence intensity ranged from 4.8 percent to 5.6 percent and the length scale ranged from 5.64 cm to 6.95 cm. The length scale values are somewhat larger than the passage height at the measurement plane (5.54 cm), which indicates that the shape of the turbulent eddies are elongated in the axial direction. The microscale values range from about 0.73 cm to about 0.98 cm. Power spectral density distributions show that a large proportion of the turbulent energy at the measurement plane is concentrated at frequencies below one kilohertz.

Taylor, J. R.↗

Heat-Conducting Anchors for Thermocouples

Metal particles in adhesive aid heat transfer. Aluminum caps containing silver-filled epoxy used as high-thermal-conductance anchors for thermocouples, epoxy providing thermal path between mounting surfaces and thermocouple measuring junctions. Normally, epoxy-filled aluminum caps used when measuring steady-state temperatures. Silver-filled epoxy used when thermocouple not isolated electrically from surface measured.

Macdavid, Kenton S.↗

Fabrication of sensitive high Tc bolometers

The rapid change of resistance with temperature of high quality films of high T sub c superconductors can be used to make resistance thermometers with very low temperature noise. Measurements on c-axis yttrium barium copper oxide (YBCO) films have given a spectral intensity of temperature noise less than 4 times 10(exp -8) K/Hz(exp 1/2) at 10 Hz. Consequently, the opportunity exists to make useful bolometric infrared detectors that operate near 90 K which can be cooled with liquid nitrogen. The fabrication and measurement of two bolometer architectures are discussed. The first is a conventional bolometer which consists of a 3000 A thick YBCO film deposited in situ by laser ablation on top of a 500 A thick SrTiO3 thickness and diced into 1x1 mm(exp 2) bolometer chips. Gold black smoke was used as the radiation absorber. The voltage noise was less than the amplifier noise when the film was current biased. Optical measurements gave an NEP of 5 times 10(exp -11) W/Hz(exp 1/2) at 10 Hz. The second architecture is that of an antenna-coupled microbolometer which consists of a small (5x10 cubic microns) YBCO film deposited directly on a bulk substrate with a low thermal conductance (YSZ) and an impedance matched planar lithographed spiral or log-periodic antenna. This structure is produced by standard photolithographic techniques. Measurements gave an electrical NEP of 4.7 times 10(exp -12) W/Hz(exp 1/2) at 10 kHz. Measurements of the optical efficiency are in progress. The measured performance of both bolometers will be compared to other detectors operating at or above liquid nitrogen temperatures so as to identify potential applications.

Nahum, Michael↗

Hydrogen effects on thermal diffusivity and electrical resistivity of zircaloy cladding

Thermal diffusivity measurements on Zirconium-based cladding materials have historically been a challenge due to the difficulty to measure on specimens with curved geometries, including nuclear grade Zircaloy cladding materials. Here, in this work, we first used laser flash analysis method and four-probe configuration method to measure the thermal diffusivity and electrical resistivity of Zircaloy tubes respectively, which show good agreement with Zircaloy plates in this work, as well as previously published data. The consistent results proved the applicability of the laser flash analysis setup and four-probe configuration method for investigating thermal diffusivity and electrical resistivity of Zircaloy tubes. We further investigated the hydrogen effect on thermal diffusivity and electrical resistivity of Zircaloy. Hydrogen plays significant roles in the thermal diffusivity of Zircaloy, which depends on the hydrogen concentration. For higher hydrogen contents (1130 and 1820 wppm in this work), where phase transformation (α-Zr + δ-hydride → α-Zr + β-Zr) occurs at 567 °C, thermal diffusivity decreases as a function of temperature at the α-Zr + δ-hydride phase regime, while increase at higher temperature at the α-Zr + β-Zr phase regime. For low hydrogen concentration, where hydride dissolved into α-Zr matrix phase at higher temperature, the thermal diffusivity is lower than non-hydrided Zircaloy-4 with similar temperature-dependent trends. Such observation demonstrates the hydrogen effects on reducing thermal diffusivity of α-Zr phase. Hydrogen increases the electrical resistivity of Zircaloy. Similar to thermal diffusivity results, the phase transformation causes a reversal of temperature-dependent trends in electrical resistivity results in Zircaloy-4 with higher hydrogen contents.

36 MATERIALS SCIENCE↗

In Situ Structural and Electrical Conductivity Characterization of Sr2MMoO6-δ Double Perovskite Solid Oxide Fuel Cell Anode Materials

In this study, a series of Sr 2 MMoO 6-δ double perovskite solid oxide fuel cell (SOFC) anode materials (where 0 <= δ <= 0.041 and M = Fe, Co, or Ni) were synthesized, and the changes in their morphologies under relevant SOFC operating conditions were explored. Ultra-small-angle X-ray scattering (USAXS), small-angle X-ray scattering (SAXS), and wide-angle X-ray scattering (WAXS) were used to determine changes in the microstructures and phase compositions of the anode materials at high temperatures and under a reducing atmosphere. The stability of the double perovskite structure was found to be highly dependent on the identity of the cation M, such that when M = Fe, the material remained stable over the course of the experiments. However, when M = Co or Ni, significant changes in the microstructure and phase composition were observed. An in situ study of the M = Co sample, in which electrical conductivity and USAXS/SAXS/WAXS measurements were conducted simultaneously, revealed the structural degradation mechanisms and electrical conductivity changes over a range of temperatures. To conduct these measurements, a cell was developed that allowed for a sample mounted on Pt wires to be placed in the X-ray beam and heated under gas flow comprising 4% mass H 2 and 96% mass N 2 . The resulting measurements allowed for the direct comparison of the electrical and morphological changes occurring in the material under operating conditions, such that increases in conductivity could be attributed to the growth of new phases.

25 ENERGY STORAGE↗

dc electric field meter with fiber-optic readout

The design of a dc electric field meter capable of measuring the magnitude and direction of the electric field at an arbitrary location above the ground plane is described. The meter is based on measuring induced charge on a split cylindrical electrode pair which is rotated around its axis of symmetry. Data readout is by fiber-optic cable using pulse frequency encoding. The sensing head is electrically isolated. Initial results are reported from a series of tests at General Electric's High Voltage Transmission Research Facility, Pittsfield, MA. The electric field was measured in a large test cage and under a dc test line. Measurement of field magnitude and direction around a human subject standing under the conductor was demonstrated.

Johnston, Alan R.↗

Initial Observations of the Magnetic Field Measurements on the C/NOFS Satellite

The Vector Electric Field Instrument (VEFI) suite onboard the C/NOFS spacecraft includes a sensitive fluxgate magnetometer to measure DC and ULF magnetic fields in the low latitude ionosphere. The instrument includes a DC vector measurement at 1 sample/sec with a range of +/- 45,000 nT whose primary objective is to enable a V x B measurement that is more accurate than that provided by using a magnetic field model. These data will also be used to provide signatures of large-scale ionospheric current systems, which, when analyzed in conjunction with the C/NOFS DC electric field measurements, promise to advance our understanding of equatorial electrodynamics. The instrument also includes an AC-coupled vector measurement in the 0.05 - 8 Hz frequency range at 16 samples/sec with an output range of +/- 900 nT in order to measure small-scale current filaments and possible Alfven waves associated with plasma irregularities. We compare the Earth's magnetic field models such as the most recently updated IGRF (the International Geomagnetic Reference Field) model and the POMME (the POtsdam Magnetic Model of the Earth) model with the measurements in order to provide an in-flight "calibration" of the data as well as compute magnetic field differences to reveal large scale ionospheric currents. Our initial results show that, on average, the POMME model accurately reproduces the C/NOFS-measured magnetic field within 20 nT in magnitude and within 0.1 deg in field direction everywhere in the low latitude ionosphere except in the region of the South Atlantic Anomaly. Initial results of the C/NOFS magnetic field measurements will be shown.

Le, Guan↗

Gas Composition Sensing Using Carbon Nanotube Arrays

This innovation is a lightweight, small sensor for inert gases that consumes a relatively small amount of power and provides measurements that are as accurate as conventional approaches. The sensing approach is based on generating an electrical discharge and measuring the specific gas breakdown voltage associated with each gas present in a sample. An array of carbon nanotubes (CNTs) in a substrate is connected to a variable-pulse voltage source. The CNT tips are spaced appropriately from the second electrode maintained at a constant voltage. A sequence of voltage pulses is applied and a pulse discharge breakdown threshold voltage is estimated for one or more gas components, from an analysis of the current-voltage characteristics. Each estimated pulse discharge breakdown threshold voltage is compared with known threshold voltages for candidate gas components to estimate whether at least one candidate gas component is present in the gas. The procedure can be repeated at higher pulse voltages to estimate a pulse discharge breakdown threshold voltage for a second component present in the gas. The CNTs in the gas sensor have a sharp (low radius of curvature) tip; they are preferably multi-wall carbon nanotubes (MWCNTs) or carbon nanofibers (CNFs), to generate high-strength electrical fields adjacent to the tips for breakdown of the gas components with lower voltage application and generation of high current. The sensor system can provide a high-sensitivity, low-power-consumption tool that is very specific for identification of one or more gas components. The sensor can be multiplexed to measure current from multiple CNT arrays for simultaneous detection of several gas components.

Li, Jing↗

Electric fields and secondary emission near a dielectric-metal interface

Dielectric surface-charge distributions near a metal-dielectric interface in vacuum depend upon secondary emission processes in the presence of normal and tangential components of electric field. From measured charge distributions created by exposing a specimen of fluorinated ethylene-propylene to monoenergetic electron fluxes, it has been possible to calculate potentials and fields on and near the dielectric surface. The effect of the normal electric field upon secondary emission is measured directly, and the effect of the tangential field is inferred from the charge-distribution data. The critical point (unity crossover) for secondary emission is shifted by the application of fields, so that it occurs at much higher primary energies than normally. Primary beams having energies up to 20 keV are used, and surface fields are as high as 20 kV/mm.

Robinson, J. W.↗

Lightning Return-Stroke Current Waveforms Aloft, from Measured Field Change, Current, and Channel Geometry

Three-dimensional reconstructions of six rocket-triggered lightning channels are derived from stereo photographs. These reconstructed channels are used to infer the behavior of the current in return strokes above the ground from current waveforms measured at the channel base and electric-field-change waveforms measured at a range of 5.2 kilometers for 24 return strokes in these channels. Streak photographs of 14 of the same strokes are analyzed to determine the rise times, propagation speeds, and amplitudes of relative light intensity for comparison with the electrical inferences. Results include the following: 1) The fine structure of the field-change waveforms that were radiated by these subsequent return strokes can be explained, in large part, by channel geometry. 2) The average 10 - 90% rise time of the stroke current increased by about a factor of seven in our sample, from an observed 0.31 plus or minus 0.17 microseconds at the surface to an inferred 2.2 plus or minus 0.5 microcseconds at 1 kilometer path length above the surface. 3) The three-dimensional propagation speed of the current front averaged 1.80 plus or minus 0.24 X 10(exp 8) meters per second over channel lengths typically greater than 1 kilometer. 4) Assuming that the measured current was entirely due to the return stroke forced an unreasonably large and abrupt reduction in inferred current amplitude over the first few tens of meters above the surface, especially in cases when the leader was bright relative to its stroke. Therefore, a significant fraction of the current at the surface was probably due to the leader, at least in such cases. 5) Peak return-stroke currents decreased by approximately 37 plus or minus 12% from 100 meters to 1 kilometer of path length above the surface. Because of uncertainty about how to partition the measured current between leader and return stroke, we are unable to infer the variation of current amplitude near the ground.

Willett, J. C.↗