Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “distributed teams”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,351 records · Page 75

The Ionosphere and Ocean Altimetry

The accuracy of satellite-based single-frequency radar ocean altimeters benefits from calibration of the total electron content (TEC) of the ionosphere below the satellite. Data from the global network of Global Positioning System (GPS) receivers provides timely, continuous, and globally well-distributed measurements of ionospheric electron content. We have created a daily automated process called Daily Global Ionospheric Map (Daily-GIM) whose primary purpose is to use global GPS data to provide ionospheric calibration data for the Geosat Follow-On (GFO) ocean altimeter. This process also produces an hourly time-series of global maps of the electron content of the ionosphere. This system is designed to deliver "quick-look" ionospheric calibrations within 24 hours with 90+% reliability and with a root-mean-square accuracy of 2 cm at 13.6 GHz. In addition we produce a second product within 72 hours which takes advantage of additional GPS data which were not available in time for the first process. The diagram shows an example of a comparison between TEC data from the Topographic Experiment (TOPEX) ocean altimeter and Daily-GIM. TEC are displayed in TEC units, TECU, where 5 TECU is 1 cm at 13.6 GHz. Data from a single TOPEX track is shown. Also shown is the Bent climatological model TEC for the track. Although the GFO satellite is not yet in its operational mode, we have been running Daily-GIM reliably (much better than 90%) with better than 2-cm accuracy (based on comparisons against TOPEX) for several months. When timely ephemeris files for the European Remote Sensing Satellite 2 (ERS-2) are available, daily ERS-2 altimeter ionospheric calibration files are produced. When GFO ephemeris files are made available to us, we produce GFO ionosphere calibration files. Users of these GFO ionosphere calibration files find they are a great improvement over the alternative International Reference Ionosphere 1995 (IRI-95) climatological model. In addition, the TOPEX orbit determination team at JPL has been using the global ionospheric maps to calibrate the single frequency GPS data from the TOPEX receiver, and report highly significant improvements in the ephemeris. The global ionospheric maps are delivered daily to the International GPS Service (IGS), making them available to the scientific community. Additional information is contained in the original.

Lindqwister, Ulf J.↗

Influence of the helicopter environment on patient care capabilities: flight crew perceptions

INTRODUCTION: Flight crew perceptions of the effect of the rotary-wing environment on patient-care capabilities have not been subject to statistical analysis. We hypothesized that flight crew members perceived significant difficulties in performing patient-care tasks during air medical transport. METHODS: A survey was distributed to a convenience sample of flight crew members from 20 flight programs. Respondents were asked to compare the difficulty of performing patient-care tasks in rotary-wing and standard (emergency department or intensive care unit) settings. Demographic data collected on respondents included years of flight experience, flights per month, crew duty position and primary aircraft in which the respondent worked. Statistical analysis was performed as appropriate using Student's t-test, type III sum of squares, and analysis of variance. Alpha was defined as p < 0.05. RESULTS: Fifty-five percent of programs (90 individuals) responded. All tasks were significantly rated more difficult in the rotary-wing environment. Ratings were not significantly correlated with flight experience, duty position, flights per month or aircraft used. CONCLUSIONS: We conclude that the performance of patient-care tasks are perceived by air medical flight crew to be significantly more difficult during rotary-wing air medical transport than in hospital settings.

Noise, Transportation/adverse effects↗

Exploring the potential benefits of high-efficiency dual-fuel combustion on a heavy-duty multi-cylinder engine for SuperTruck I

In support of the Daimler SuperTruck I team’s 55% brake thermal efficiency (BTE) pathway goal, researchers at Oak Ridge National Laboratory performed an experimental investigation of the potential efficiency and emissions benefits of dual-fuel advanced combustion approaches on a modified heavy-duty 15-L Detroit™ DD15 engine. For this work, a natural gas port fuel injection system with an independent injection control for each cylinder was added to the DD15 engine. For the dual-fuel strategies investigated, 65%–90% of the total fuel energy was supplied through the added port fuel injection natural gas (NG) fueling system. The remaining fuel energy was supplied by one or more direct injections of diesel fuel using the production high pressure diesel fueling system. The production DD15 air handling system and combustion geometry were unmodified for this study. Efficiency and emissions with dual-fuel strategies including both low temperature combustion (LTC) and non-LTC approaches such as dual fuel direct-injection were investigated along with control authority over combustion phasing. Parametric studies of dual-fuel NG/diesel advanced combustion were conducted in order to experimentally investigate the potential of high-efficiency, dual-fuel combustion strategies to improve BTE in a multi-cylinder engine, understand the potential reductions in engine-out emissions, and characterize the range of combustion phasing controllability. Characterization of mode transitions from mixing-controlled diesel pilot ignition to kinetically controlled ignition is presented. Key findings from this study included a reproducible demonstration of BTE approaching 48% at up to a 13-bar brake mean effective pressure with significant reductions in engine-out NOx and soot emissions. Additional results from investigating load transients in dual-fuel mode and initial characterization of particle size distribution during dual-fuel operation are presented.

33 ADVANCED PROPULSION SYSTEMS↗

3P Program: Phenotyping X Prediction = Productivity (Final Scientific/Technical Report)

The goal of the 3P Program was to establish integrated, real-time phenotyping and to analyze above- and below-ground plant architecture and total carbon partitioning and allocation to predict heterosis and develop superior crop hybrids by fully leveraging the Sorghum gene pool. There were two overarching themes: 1) the development of a new crop improvement approach utilizing advances in high-throughput phenotyping (HTP), computing, and genomics for public dissemination and 2) leveraging this platform for sorghum crop improvement and commercialization. The Clemson team worked on creating genomic resources and using both statistical learning and high-throughput phenotyping in genomics-assisted breeding. Research was broadly interested in the genetics of carbon partitioning, with the aim of improving crop performance and achieving sustainability. The technology and resources created can be readily found in the public domain and serve to advance scientific understanding of crop genomics and breeding. Genomic prediction was able to identify top crosses to be made, and a hybrid prediction pipeline is in place to drive year-over-year genetic gain. Roots have long been ignored by plant breeders and agronomists, not because they are unimportant but because they are hard to measure. This is an untapped white space of potential insight and innovation. To address this, Hi Fidelity Genetics developed the RootTracker to measure roots in the field on a continuous basis. A database system called RootTracker Tracker was developed to handle data coming from the RootTrackers. In using this device, valuable data was observed for plant breeding, hydrochemical development, and other agricultural biology applications. Carnegie Mellon’s goal was developing new techniques to generate high-resolution 3D models of plants from data collected in the field. The idea was that more useful and more informative phenotypes could be extracted by resolving small features, such as seeds and flowers, and that by modeling in 3D, the spatial structure of plants could be examined. To achieve this, multiple images collected by a new small format structured light stereo imager were fused together. A sorghum panicle modeling pipeline was developed to allow the collection and processing of data. Carolina Seed Systems is an agricultural technology company focused on decarbonizing the agricultural system. Their technology pipeline serves to drive fundamental progress towards creation and distribution of carbon negative crops. The genomic and the engineering technology developed through the 3P Program was leveraged to deliver both value and sustainability from the grower to the consumer. Promising sorghum hybrids were scaled up and commercialized. The overall goal of our research was to integrate, create, and deploy genetic and engineering concepts and technologies to enhance crop productivity in a sustainable fashion. The combination of public and private partners allowed the basic research and hypothesis testing to be quickly accelerated for commercial application by the companies yet maintained that the core framework and academic insights remain in the public domain for continued market disruption, competition, and innovation.

59 BASIC BIOLOGICAL SCIENCES↗

Semi-Annual Report for Horizontal Compact High Temperature Gas Reactor (HC-HTGR) Development during Performance Period April 2023 – September 2023

Horizontal Compact High Temperature Gas Reactor (HC-HTGR) is being designed by a multi-disciplinary team of nuclear, mechanical, and structural engineers under the support of a DOE-NE Advanced Reactor Demonstration Program’s Advanced Reactor Concepts-20 (ARC-20) award. The objective of this ARC-20 project is to deliver a conceptual design for the proposed HC-HTGR in 3 years and support its commercialization as a safe, low-cost HTGR. Argonne National Laboratory (Argonne) is responsible for the design and analysis of the reactor cavity cooling system (RCCS) as a safety system for passive decay heat removal of the reactor concept. Additionally, Argonne is providing analysis of the primary coolant system to ensure temperatures within the core remain below safety margins during steady-state and potential accident scenarios. This fourth semi-annual report summarized the progress made at Argonne on the two tasks during the second half of FY23. As a part of the RCCS design task, recent efforts have been made to complete a conceptual design of the RCCS for the HC-HTGR, including the design update of the water panel and system configuration favorable in point of view of fabrication and system operation. Design calculations were conducted under various heat load conditions to validate the system design. Transient simulations using RELAP5-3D were conducted to investigate system dynamics under transients of interest and to evaluate the system performance in the design condition. The results demonstrated the overall system feasibility that the RCCS design maintains structures temperatures lower than maximum allowable temperature with sufficient system inventory without any active heat sink. In the primary system thermal hydraulics task, the preliminary analysis was performed for a long term pressurized conduction cooldown (PCC) transient. This analysis used a combination of a fully resolved and coarse homogenized mesh to predict the temperature distribution for the steady-state initial condition and the PCC transient. The steady-state initial condition was determined using a fully resolved full core model with 3D solid to 1D fluid coupling. The fully resolved mesh was also used to model the first 20 seconds of the PCC. The temperature difference between fuel pins and the graphite matrix becomes minimal and the dominant heat transfer shifts to a larger scale radially towards the RCCS. After 20 seconds, a homogenized coarse mesh is used, greatly reducing the computational costs of the model. These results demonstrate that the core is designed to passively remove enough decay heat in a protected loss of primary coolant flow to prevent an unsafe rise of core temperatures.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Technical Report Series on the Boreal Ecosystem-Atmosphere Study (BOREAS) RSS-19 1994 CASI At-Sensor Radiance and Reflectance Images

The Remote Sensing Science (RSS)-19 team collected Compact Airborne Spectrographic Imager (CASI) images from the Chieftain Navaho aircraft in order to observe the seasonal change in the radiometric reflectance properties of the boreal forest landscape. CASI was deployed as a site-specific optical sensor during Boreal Ecosystem-Atmosphere Study (BOREAS) field campaigns. Image data were collected with CASI on 36 days during five field campaigns between February and September 1994, primarily at flux tower sites located at study sites near Thompson, Manitoba, and Prince Albert, Saskatchewan. A variety of CASI data collection strategies were used to meet the following scientific objectives: 1) canopy bidirectional reflectance, 2) canopy biochemistry, 3) spatial variability, and 4) estimates of up and downwelling Photosynthetically Active Radiation (PAR) and spectral albedo, as well as changes along transects across lakes and transects the Northern Study Area (NSA) and Southern Study Area (SSA). The images are stored as binary image files. A subset of the 1994 CASI acquisitions have been compressed and included on the BOREAS CD-ROM set. This subset includes three images for the NSA-OBS (Old Black Spruce) site on 06 Jun 94, 08 Aug 94, and 06 Sep 94, one image for the SSA-OBS site on 24 Jul 94; and one image for the NSA-Fen site on 08 Aug 94. The CASI imagery on the BOREAS CD-ROMs have been compressed using the Gzip program. The rest of the 1994 BOREAS CASI archive are not contained on the BOREAS CD-ROM set. Inventory listing files are supplied on the CD-ROM to inform users of the data that were collected. The RSS-19 1994 CASI images are available from the Earth Observing System Data and Information System (EOSDIS) Oak Ridge National Laboratory (ORNL) Distributed Active Archive Center (DAAC). The data files are available on a CD-ROM (see document number 20010000884).

Miller, John↗

Low-cost Manufacturing of Semitransparent CdTe PV for Building Integration

Solar has been demonstrated to be a robust renewable energy source, constituting a significant portion of the United States’ renewable energy portfolio. Despite its growth across residential, commercial, and utility sectors over the past decades, it remains a small fraction of the overall energy infrastructure. Challenges persist in fully harnessing solar power to meet the nation's escalating energy demands. Among these challenges lies the hurdle of efficiently distributing large quantities of solar-generated electricity to densely populated regions with the highest energy needs and costs. Traditional utility-scale arrays demand extensive land, a luxury often unavailable in metropolitan areas. Consequently, installations must be situated at a distance, necessitating additional infrastructure for electricity transmission to service areas. While metropolitan landscapes lack sprawling open spaces suitable for conventional utility-scale solar deployment, they offer a different resource: windows. Semitransparent photovoltaic window technology has the potential to not only bolster the grid's energy capacity, but to also provide HVAC and economic advantages to building owners. However, commercial availability of building-integrated photovoltaic windows remains limited. Silicon based photovoltaics currently dominate the solar market but adapting them for use in windows poses a variety of engineering and economic challenges such as relatively low power density, high costs associated with custom manufacturing, and aesthetic considerations. Addressing these challenges, this project explored the use of laser ablation patterning to manufacture cost-effective, high-efficiency, semitransparent Cadmium Telluride photovoltaic modules. Results showcased the potential of this methodology in developing photovoltaic windows and other innovative semitransparent PV applications. The ablation manufacturing technique demonstrated great versatility in achieving different patterns and levels of visible light transmission, and the power loss due to ablation was nearly directly proportional to the amount of material removed. Furthermore, the manufacturing process for Cadmium Telluride modules already has established advantages in material and energy efficiency, and the conversion of a standard submodule to semitransparent essentially requires a single additional process step, ensuring scalability. It is important to note that during this work, Toledo Solar experienced substantial organizational upheaval stemming from a lawsuit with First Solar. An external investigation led the board of directors to remove and replace the previous management team, and several other members of the staff elected to depart as well, including the then acting Principle Investigator on this project. The remaining Toledo Solar team attempted to recover from the disruption and deliver on the remaining tasks, but upon its own review, the Department of Energy ruled the project in default and terminated the contract in December 2023.

14 SOLAR ENERGY↗

Semi-Annual Report for Modular Integrated Gas High Temperature Reactor Development during Performance Period April 2022 - September 2022

Horizontal Compact High Temperature Gas Reactor (HC-HTGR) is being designed by a multidisciplinary team of nuclear, mechanical, and structural engineers under the support of a DOE-NE Advanced Reactor Demonstration Program’s Advanced Reactor Concepts-20 (ARC-20) award. The objective of this ARC-20 project is to deliver a conceptual design for the proposed HC-HTGR in 3 years and support its commercialization as a safe, low-cost HTGR. Argonne National Laboratory (Argonne) is responsible for the design and analysis of the reactor cavity cooling system (RCCS) as a safety system for passive decay heat removal of the reactor concept. Additionally, Argonne is providing analysis of the primary coolant system to ensure temperatures within the core remain below safety margins during steady-state and potential accident scenarios. This second semi-annual report summarized the progress made at Argonne on the two tasks during the second half of FY22. As a part of the RCCS design task, a scoping calculation in estimating HVAC capability for the HC-HTGR reactor building was performed. A water panel modeling study was first performed with the test case, which confirms the capability of the RELAP5-3D modeling approach to explore various design options of the HC-HTGR RCCS under consideration. Then, a reference RELAP5-3D model for the unit geometry of the preliminary design of the HC-HTGR RCCS was developed. A preliminary performance analysis was conducted to evaluate the performances of a single-phase natural circulation and panel conduction in various operating conditions. For the primary coolant system analysis task, preliminary thermal hydraulic analysis of the HC-HTGR core design was performed with a high resolution 1D fluid-3D solid coupled model using the System Analysis Module (SAM) to assess the assembly coolant channel and bypass flow mass flow rate distribution. Some preliminary work on the development of a full core reduced order model was discussed following the assembly level model to predict the core wide coolant flow distribution and to model certain operational and accidental transients.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Creative Analytics of Mission Ops Event Messages

Historically, tremendous effort has been put into processing and displaying mission health and safety telemetry data; and relatively little attention has been paid to extracting information from missions time-tagged event log messages. Todays missions may log tens of thousands of messages per day and the numbers are expected to dramatically increase as satellite fleets and constellations are launched, as security monitoring continues to evolve, and as the overall complexity of ground system operations increases. The logs may contain information about orbital events, scheduled and actual observations, device status and anomalies, when operators were logged on, when commands were resent, when there were data drop outs or system failures, and much much more. When dealing with distributed space missions or operational fleets, it becomes even more important to systematically analyze this data. Several advanced information systems technologies make it appropriate to now develop analytic capabilities which can increase mission situational awareness, reduce mission risk, enable better event-driven automation and cross-mission collaborations, and lead to improved operations strategies: Industry Standard for Log Messages. The Object Management Group (OMG) Space Domain Task Force (SDTF) standards organization is in the process of creating a formal standard for industry for event log messages. The format is based on work at NASA GSFC. Open System Architectures. The DoD, NASA, and others are moving towards common open system architectures for mission ground data systems based on work at NASA GSFC with the full support of the commercial product industry and major integration contractors. Text Analytics. A specific area of data analytics which applies statistical, linguistic, and structural techniques to extract and classify information from textual sources. This presentation describes work now underway at NASA to increase situational awareness through the collection of non-telemetry mission operations information into a common log format and then providing display and analytics tools to provide in-depth assessment of the log contents. The work includes: Common interface formats for acquiring time-tagged text messages Conversion of common files for schedules, orbital events, and stored commands to the common log format Innovative displays to depict thousands of messages on a single display Structured English text queries against the log message data store, extensible to a more mature natural language query capability Goal of speech-to-text and text-to-speech additions to create a personal mission operations assistant to aid on-console operations. A wide variety of planned uses identified by the mission operations teams will be discussed.

events↗

Field Validation of Thermoelectric Generation System at Holcim Cement Plant in Alpena, Michigan

Executive Summary Project Background The Industrial Technology Validation (ITV) program aims to identify and demonstrate the performance of new, emerging, and underutilized energy-saving technologies in the industrial sector to help inform decisions to help accelerate their commercialization and deployment, as well as to help make industries more competitive. This ITV demonstration evaluated a thermoelectric generation (TEG) technology at a cement plant, aiming to reduce energy demand in the cement industry. A median cement plant consumes 5.73 million British thermal units per ton of clinker production (resulting in 0.838 metric tons of carbon dioxide [CO₂] emissions per ton of clinker) (Boyd and Zhang 2011, EPA 2021), equivalent to approximately 6.9 trillion British thermal units (TBtu) per year in energy consumption at a cement plant producing 3,300 tons of clinker per day.¹ Collaborating with Holcim, Advanced Thermovoltaic Systems (ATS) developed and deployed a pilot-scale thermoelectric power system to efficiently capture and convert waste heat to electricity. The system leverages the Seebeck effect to convert temperature differences on two sides of semiconductor cartridges into electrical power (ScienceDirect, n.d.). This generation is realized with minimal moving parts compared to existing waste-heat-to-generation solutions and allows capture from heat sources with temperatures as low as 150°C. This project aimed to validate a scalable solution applicable for capturing medium-temperature waste heat, including ambient losses from other high-temperature processes, and high-temperature sources less suitable for other waste-heat-to-power solutions. By recovering this otherwise wasted heat, this project intends to validate improvements to overall process efficiency through reduction in purchased electricity, thereby reducing operational costs while enhancing resiliency and competitiveness. Description and Scope This study evaluated the performance of a TEG system from ATS as a solution to convert waste heat into useful power at a Holcim cement plant in Alpena, Michigan. This plant is a fully integrated cement plant that has been operating since 1907. The facility operates continuously (24/7/365) with approximately 250 employees and five long dry kilns, yielding a total production capacity of 7,852 tons of cement per day (EPA 2023). Currently, the Alpena plant uses waste heat boilers to convert waste heat from the exhaust of each kiln into steam, which drives steam turbine generators. The ATS TEG is being evaluated for its potential to supplement the steam turbines by capturing the remaining lower grade heat. This technology is also being considered for other Holcim plants where steam turbines are not a viable option. ATS installed a pilot-scale TEG unit with an array of 582 individual thermoelectric semiconductor cartridges, of which 573 were operational. The cartridges are sandwiched between 48 hot plates and 49 cold plates. Each cartridge is designed to generate 20 watts (W) of gross power at a hot-side temperature of 240°C and cold-side temperature of 20°C. As such, the total gross generation capacity of the installed system is 11.5 kilowatts (kW) at design conditions. The system configuration for the evaluation was designed to prioritize convenience of installation and minimize disruption to production at the site, while ensuring that the heat required can be obtained for evaluating the TEG system at various operational conditions. To accomplish this, a portion of the steam supplied to Alpena’s steam turbine generation system was diverted to be used as the heat source for the TEG system, while water was supplied to the cold side of the system from nearby Lake Huron. This configuration was designed for the evaluation of the pilot-scale system to assess the performance at different conditions. A commercial-scale system will likely vary from the pilot system depending on typical configurations, including both scale and application. Future commercial applications of the ATS system would involve integrating the system into the exhaust from kiln preheaters, clinker coolers, or radiant heat capture from kiln shells for the heat source. For the cold source, a range of cooling solutions can be considered, including a mechanical cooling system, depending on the location and the application. To increase the generation capacity for commercial applications, the technology provider is working toward developing a commercial-scale TEG system, which would combine multiple TEG units (each similar in design to the pilot system) together. The scope of this evaluation includes the pilot-scale TEG system and all impacted equipment including pumps, controllers, and power handling equipment. Study Objectives The evaluation's goal was to assess the potential of the ATS TEG system to generate useful electrical power by capturing waste heat from cement production kilns. The objectives of this study are to evaluate and verify the following claims made by ATS regarding the pilot-scale system installed at the Holcim Alpena plant. The following design parameters and claims are also outlined in Table ES- 1 and Table ES- 2: • Gross Power: The thermoelectric system converts heat into power to create gross power, the total measured power generated by the system. The 573 active cartridge pilot-scale system is expected to generate 11.5 kW of gross power at the designed hot-side temperature of 240°C and cold-side temperature of 20°C. Power production is dependent on the temperature difference between the heat source (ultimately from the waste heat) and cold temperature supply source. • Net Power: The net power is the total usable power provided to the site by the TEG system after deducting parasitic power loads from the gross generated power. Supplementary equipment is required to operate the TEG system including pumps, controllers, and, in certain anticipated applications, mechanical cooling, which introduce parasitic loads to system operation. After deducting the parasitic loads from the gross power generation, ATS anticipates achieving a net power generation of 7.5 kW from the pilot-scale system. • Thermal Efficiency: The thermal efficiency is the percent of the total heat transferred to the TEG system that is converted to gross power. Historically, TEGs have a thermal efficiency of 2%–5% (DOE 2008). Prior industrial-scale TEG systems, such as the E1 TEG offered by Alphabet Energy, operated at an efficiency of 2.5% (Lamonica, 2014). ATS anticipates achieving an average efficiency of 4.8% or higher in converting heat energy to usable electricity. • Cartridge Performance: The TEG system comprises 573 active individual semiconductor cartridges, each of which generates a portion of the total power. Cartridge optimization and selection is an important design consideration for potential future TEG system design performance. Therefore, understanding the distribution of gross power and efficiency within the pilot system is vital to understanding what is achievable. At a design hot-side temperature of 240°C and cold-side temperature of 20°C, ATS anticipates a cartridge performance of 20 W of gross power per cartridge at an efficiency of 4.8% per cartridge. In addition to evaluating the claimed performance of the TEG pilot-scale unit, the study estimated the potential annual impacts of a scaled-up commercial system used to capture kiln waste heat over annual operations. The evaluation estimated the gross and net annual electric generation achievable by capturing heat from the two proposed tap-in points: the kiln exhaust and the clinker cooler exhaust; see Section 2.1 for details. Two use cases were examined: • Holcim Alpena: The Holcim Alpena site consists of long dry kilns with superheater boilers, which differs from the rest of Holcim’s cement plant portfolio and results in lower waste heat temperatures. The study estimates gross and net annual generation using the superheater boiler exhaust and clinker cooler exhaust, based on 2023 operational data. • Typical Installation: Common cement plants have preheater kilns with higher exhaust temperatures than Holcim Alpena across a range of production rates. The study estimates gross and net annual generation using the preheater exhaust and clinker cooler exhaust, with a sensitivity analysis to account for the typical range of preheater exhaust temperatures, clinker cooler exhaust temperatures, and clinker production rates. Methodology The evaluation methodology followed a measurement and verification (M&V) strategy based on the International Performance Measurement and Verification Protocol Option B through comprehensive measurements and analyses of the affected systems. Evaluation data was collected from March 9 to March 11, 2024, the test period of the pilot TEG system. During the test period, in coordination with the ITV team, the ATS team adjusted system operations to capture the range of variability expected for each of the variables pertinent to performance of the system. The methodology consisted of two parts: evaluating the performance of the pilot unit's TEG system and estimating the annual TEG impact in terms of gross and net power based on a given waste heat profile. First, the evaluation of the thermoelectric generation performance of the pilot unit relative to the claims was performed by analyzing the collected test data. Gross power of the pilot TEG system was directly measured. Net power was determined by deducting the measured parasitic power from the gross power. The gross power generation was compared to heat transferred to the system by the working fluid (which was heated by steam generated from the kiln waste heat) to calculate the thermal efficiency achieved by the system. Performance of individual semiconductor cartridges within the pilot array was also assessed in terms of measured gross cartridge power and calculated cartridge thermal efficiency. The second part of the evaluation estimated the annual TEG impacts in terms of gross power and net power (calculated from the difference between gross power and parasitic power). This analysis comprised development of mathematical regression models for gross power and parasitic power, with assessment of each model’s goodness-of-fit characteristics to ensure satisfaction of statistical requirements. The models predicted the gross power generation, the parasitic load based on the temperature difference between the hot working fluid and the cold-side fluid (cold water from Lake Huron) entering the system, the volumetric flow rate of the cold-side fluid at the inlet, and the volumetric flow rate of the hot working fluid at the inlet. The annual impact analysis considered a theoretical commercial-scale system sized to capture the available waste heat at a cement plant, consisting of linked pilot-scale units that receive heat from a theoretical gas-to-working-fluid heat exchanger. To estimate annual impacts at the Alpena plant, the gross power and parasitic power regression models were applied to the arrays in the theoretical commercial-scale system. The heat supplied to the unit was calculated based on the kiln run time, annual production, kiln exhaust waste heat, and clinker cooler waste heat derived from 2023 Holcim Alpena kiln operational data. Net power impacts were calculated by deducting the resulting parasitic power from the estimated gross power. Inputs for the model were generated from a combination of hourly data, assumed design considerations for TEG system scale-up from the pilot-scale unit, and assumptions regarding TEG system operations. This analysis was then used as the basis for estimating annual impacts of typical TEG installation at cement plants, by applying sensitivity analyses to key kiln operational characteristics including kiln preheater exhaust temperatures, cooler clinker exhaust temperatures, and plant daily production rates across a range of expected values. Project Results/Findings Table ES- 2 and Table ES- 2 provide a summary of the operating conditions and evaluation results compared to the stated claims from the technology provider. Key takeaways include: • Gross Power: The peak gross power achieved during the testing period was 10.0 kW, compared to the 11.5 kW expected for 573 active cartridges. The claimed gross power was associated with a target hot side of 240°C; however, the system only received a maximum hot-side mean plate temperature of 212°C during the testing period. • Net Power: The pilot-scale unit exceeded the claims for net power, achieving a peak of 7.7 kW net compared to a claim of 7.5 kW. One factor contributing to the higher achieved net power is the relatively high water pressure available through Lake Huron. The pilot TEG system did not require cold-side pumps during the test, whereas most installations would. This reduced the parasitic loads on the system, ultimately contributing to higher net power relative to the gross power. • Thermal Efficiency: The pilot-scale unit outperformed the claimed efficiency, achieving a peak system efficiency of 5.0% thermal efficiency compared to the stated 4.8%. • Cartridge Performance: To compare cartridge performance against claims, the study focused on the third day of testing, which aimed for conditions closest to the design specifications, with a hot side of 240°C and cold-side exit temperature of 6.4°–30°C. On this day, the mean gross power observed in the cartridges within the TEG array was 18.1 W/cartridge, and the peak performance was 34.7 W/cartridge. The estimated mean cartridge efficiency was 5.2%, and the estimated efficiency at peak gross cartridge power was 10%. The regression models developed for gross power generation and parasitic loads were used to estimate the generation impact for given heat input to the TEG from the working fluid (captured from the waste heat) and from the cold loop (Lake Huron) on an hourly basis for a year of operation. Based on this analysis, installation of a commercial-scale TEG system at the Holcim cement plant in Alpena, Michigan, with a waste heat exchanger of 0.85 effectiveness, would generate up to 391 kW of net power, translating to between 920,000 and 1,800,000 kilowatt-hours (kWh) in net electricity per year. Based on typical grid emissions for Alpena, this would avoid estimated net emissions by 752 metric tons of CO₂ annually.² The sensitivity analysis estimated that typical TEG system installations at cement plants could generate an average of 56–1,040 kW of net power, or between 488,000 and 9,110,000 kWh of net energy. This generation potential is most significantly affected by plant production rates and also influenced by preheater and clinker cooler exhaust temperatures. Applying the national average emission rate, typical commercial-scale installations at Holcim plants are projected to avoid between 182 and 3,401 metric tons of CO₂ annually per site. Table ES- 3 shows a summary of the estimated annual impacts.³ While parasitic loads are significant and vary by application, this analysis assumed the use of heating loop pumps and access to Lake Huron as a cold sink. This setup assumed no need for cooling loop pumps due to the available water pressure at the test site. Applications that require cooling towers or additional equipment are likely to experience higher parasitic loads. Therefore, the study’s estimates are most applicable to scenarios with similar parasitic load configurations—namely, access to a high-pressure cold sink. Applicability to other locations may be limited, as differing conditions could necessitate additional pumps and cooling systems, potentially impacting performance significantly.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Permafrost Thaw, Uneven Subsidence and Projected Drying of Ice-wedge Polygon Tundra: Modeling Archive

This dataset is a model archive of the paper Permafrost Thaw, Uneven Subsidence and Projected Drying of Ice-wedge Polygon Tundra (in prep) to support a modeling study investigating how projected increases in Arctic temperature and precipitation will jointly influence hydrologic conditions in ice-rich tundra landscapes. With this dataset, this study is to address the research question: Will Arctic tundra landscapes become wetter or drier with increasing precipitation and temperature in the future when thaw-induced ground subsidence and associated microtopographic evolution are represented? The simulations focus on ice-wedge polygon tundra, a widespread form of ice-rich permafrost terrain that is highly sensitive to thaw-driven landscape change. This dataset contains model input and output data for four study watersheds in Alaska: Anaktuvuk, Utqiagvik (formerly Barrow), Brooks Foothills, and Prudhoe Bay. Simulations were performed using the Advanced Terrestrial Simulator (ATS, v1.5), a physics-rich integrated surface–subsurface hydrologic model. For each watershed, ten modeling cases were performed representing two landscape evolution conditions (with subsidence and without subsidence) combined with five climate forcing scenarios derived from Shared Socioeconomic Pathways (SSP5, SSP5 with precipitation trend, SSP2, SSP2 with precipitation trend, and SSP2 with double precipitation trend). Particularly, for each watershed under the forcing SSP2 with precipitation trend, there are two additional simulations considering spatially heterogeneous subsidence distributions: one assumes randomly distributed scaling and the other includes elevation dependent distribution scaling. These simulations span 1980–2099 and include spin-up runs (1980–2009) followed by transient projections (2010–2099). To facilitate reproducibility of simulations, all datasets are organized by watershed. For each study watershed, the dataset contains: (1) Pre-partitioned mesh files for 32-core modeling (.par.32.XX), located in EACH_WATERSHED/mesh/basin; and also a non-partitioned mesh file (.exo) located in EACH_WATERSHED/mesh; (2) Climate forcings corresponding to the five SSP scenarios (.h5), located in EACH_WATERSHED/data; (3) Final states (.h5) from column spin-up modeling used to initialize historical watershed-scale spin-up runs from 1980 to 2009, located in EACH_WATERSHED/PreSpinupHistorical; (4) Final states (.h5) of historical watershed-scale spin-up runs from 1980 to 2009 used to initialize projection runs, located in EACH_WATERSHED/Spinup_daymetERA5; (5) ATS modeling input files (.xml), located in EACH_WATERSHED/EACH_SIMULATION_SCENARIO/inputfiles; (6) ATS modeling output files (.dat), located in in EACH_WATERSHED/EACH_SIMULATION_SCENARIO/combined_obs; (7) For the Brooks Foothills watershed, additional spatial model outputs are provided (.h5) for selected years (2033 and 2093) used to generate spatial figures in this study, located in Brooksfoothills/EACH_SIMULATION_SCENARIO/results-WITH/WITHOUT_SUBSIDENCE-year2033/2093. All data files with suffix .h5 can be accessible through Python h5py, and all data files with suffix of .dat can be imported by Python pandas. Mesh file with .exo can be visualized through Paraview or read by Python netCDF. The Next-Generation Ecosystem Experiments in the Arctic (NGEE Arctic) project is a research effort to reduce uncertainty in the Department of Energy’s Energy Exascale Earth System Model (E3SM) by developing a predictive understanding of Arctic tundra ecosystems underlain by permafrost and to quantify feedbacks from the Arctic tundra to the Earth system. NGEE Arctic is supported by the Department of Energy's Office of Biological and Environmental Research. Over Phases 1–3, observations made by the NGEE Arctic team across a gradient of permafrost landscapes in Arctic Alaska improved the representation of tundra processes in the land surface component of E3SM (the E3SM Land Model, ELM). Model improvements emphasized unique aspects of permafrost environments and explored reductions in model complexity while retaining predictive power. The Arctic-informed ELM developed by NGEE Arctic has been used to make novel predictions on processes ranging from permafrost thaw to soil biogeochemical cycling to Earth system feedbacks associated with the unique characteristics of tundra plants. In Phase 4, the NGEE Arctic team is evaluating our new predictive understanding under novel conditions across the Arctic domain. In collaboration with partners at long-term pan-Arctic research sites we are examining whether an Arctic-informed ELM can faithfully simulate interactions among surface and subsurface processes at site, regional, and pan-Arctic scales. In turn, we are using variety of tools to dynamically extend and evaluate ELM inference, with an emphasis on data synthesis and pan-Arctic model evaluation, reintegration of code with an evolving E3SM, scaling across heterogeneous Arctic landscapes, and the appropriate representation of the impacts of increasingly frequent Arctic disturbances.

EARTH SCIENCE > ATMOSPHERE > PRECIPITATION↗

Solar Photovoltaic (PV) Damage Assessment After Typhoon Mawar: Findings and Recommendations for Resilient PV on Guam

A team from the National Renewable Energy Laboratory (NREL) visited Guam in August 2023 to assess failure modes of solar photovoltaic (PV) systems after Typhoon Mawar and to provide recommendations to increase the resilience of PV systems on Guam. The team visited 30 systems: commercial and utility scale, and rooftop and ground-mounted. The team observed systems with no apparent damage, as well as systems that were completely lost. Systems fared very well overall. The average failure rate of rooftop systems was 18%, with a median failure rate of 2%, meaning the few systems that suffered total loss pulled up the average. Only eight 8 of the 25 rooftop systems suffered more than 5% damage. All ground-mounted systems suffered less than 0.5% damage, aside from a carport that lost 16% of its modules. PV systems at Andersen Air Force Base suffered 5% damage on average, with a median system failure of 0.6%. In almost all cases, failures were the result of: (1) Inadequate clamping of the module frame to the mount, (2) Module mounting clamps rotating out of underlying support rail (i.e., T-bolt that rotates free at less than 60 degrees of rotation), (3) An object hitting the panel resulting in a fracture, and in some cases leading to a cascading failure of several more panels, and (4) Excessive tilt angle (in Guam, greater than 5 degrees can be a risk due to wind speed, and power production trade-offs are insignificant).

14 SOLAR ENERGY↗

Open Building Operating System: An Open-Source Grid Responsive Control Platform for Buildings

Grid-interactive efficient buildings (GEBs) with flexible loads are a promising method to decarbonize buildings, shift loads during peak hours, and lower energy use and electricity costs. Despite the promising benefits of GEBs, automation systems that manage flexible loads in response to energy prices or other grid signals are still uncommon in small and medium commercial buildings. Recent literature demonstrates such control solutions, but they often rely on custom integrations lacking the tools and drivers needed for scalability. To address these gaps, our team has created a fully open-source software stack capable of integrating heterogeneous flexible building loads and implementing integrated portable control applications called the Open Building Operating System (OpenBOS). The software can be deployed over existing control architecture with a small capital cost. OpenBOS leverages semantic models, which have been the subject of recent investigations to facilitate application portability. The use of semantic data reduces the labor and expense required to deploy and update smart control applications, increasing scalability. In this paper, the semantic modeling schema "Brick" was used, but the proposed approach can also be applied to ASHRAE standard 223P, when released. This paper describes the methodology and software components of OpenBOS and demonstrates its functionality with a rule-based demand flexibility control application configured using a semantic model. This application was tested at a real building in NY that uses a dual-fuel heating system made up of five ductless heat pump mini-splits and a central furnace serving a single zone. The demonstration reduced electricity costs at the site by 27%, demand during a shed event by 49%, and furnace usage by 35%.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Formulation and Experimental Validation of an Agricultural Implement-Only MPR System for Maximum Compatibility with Existing Agricultural Tractors

Tightening emissions regulations and rising fuel costs have driven a desire across many industries for more efficient actuation systems. This is particularly true of the agricultural sector. An extremely common arrangement in this sector is the tractor and implement pairing, in which actuators on an implement are powered by a hydraulic supply system on the towing tractor. This arrangement complicates the development of energy efficient hydraulic systems, as many new system designs require modification of both machines to reap efficiency benefits. Past work by the authors’ team has demonstrated great potentials for Multi-Pressure-Rail (MPR) technology involving both the tractor and implement subsystems. However, applicability of this MPR technology in a more realistic scenario where only one vehicle is equipped with such technology was not addressed. This work proposes an implementation of the MPR technology to an agricultural planter that allows significant savings, while only modifying the implement machine. This is done by manipulating the load sense network of a stock tractor to set system pressures to those required by the MPR system. This greatly reduces the barrier to implementation of MPR technology in agriculture. The work begins by outlining the reference machine for the system, then reviews the MPR system working principle. After this, the proposed expansion to the MPR concept is laid out and applied to the reference system. Finally, experimental validation is carried out, demonstrating up to a 35% reduction in system power consumption when paired with a state of the art, double-LS System tractor, and 15% with a single-LS System tractor.

24 POWER TRANSMISSION AND DISTRIBUTION↗

VRN3P: Variational Recurrent Neural Network Based Net-Load Prediction under High Solar Penetration

This is the final technical report for the SETO-funded VRN3P project (PNNL# 76914). The goal of this project, led by Pacific Northwest National Laboratory (PNNL), in collaboration with Lawrence Livermore National Laboratory (LLNL) and Portland General Electric (PGE), was to develop and validate a deep variational recurrent neural network-based net-load prediction (VRN3P) framework for probabilistic time-series forecasting of day-ahead net-load under high solar penetration scenarios. The project team reports successful design of a novel probabilistic net-load forecasting architecture, comprising of a variational autoencoder and a recurrent neural network, which demonstrates 30% improvement in forecast performance, 60% improvement in training time, and consumes 44% less memory, when compared with conventional baseline models. The team tested the VRN3P model performance on GridLAB-D test-cases representing varying BTM solar penetration levels of 20%, 30%, and 50%, with integrated time-series net-load profiles provided by the utility partner (PGE). The VRN3P model demonstrate <2% hourly MAPE (averaged over the year) for day- ahead net-load forecast on the test scenario with 20% BTM solar. Transfer learning extension of the VRN3P model has demonstrated 8.33× speed-up in training, while still achieving acceptable forecast performance of 2.24% hourly MAPE on the 30% BTM solar penetration test-scenario. A preliminary version of the VRN3P GridAPPS-D™has been developed, along with a web-based interactive user-interface (named ‘Forte’) which has made available on GitHub for public use.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Play-Based Exploration of CO 2 Storage in the Illinois Basin: Development and Application of the Play-Based Exploration Workflow

This report documents the workflow developed and applied for a play-based exploration (PBE) of carbon capture and storage (CCS) potential in the Illinois Basin, conducted under U.S. Department of Energy Cooperative Agreement DE-FE0032366. The project was led by the Illinois State Geological Survey (ISGS) at the University of Illinois Urbana-Champaign in collaboration with Visage Energy. The goal of this workflow is to identify locations where subsurface, surface, and societal conditions align to support safe and effective geologic CO 2 storage. To achieve this, the project team developed a systematic, seven-step workflow for conducting play-based exploration: (1) defining play elements, (2) collecting data, (3) constructing a geodatabase, (4) defining suitability criteria, (5) conducting suitability mapping, (6) generating Common Risk Segment (CRS) maps, and (7) creating composite play maps. The workflow is designed to be repeatable and adaptable for CCS assessments in other regions or for alternative subsurface energy applications such as hydrogen or natural gas storage.

01 COAL, LIGNITE, AND PEAT↗

PR100 One-Year Progress Summary Report: Preliminary Modeling Results and High-Resolution Solar and Wind Data Sets

The Puerto Rico Grid Resilience and Transitions to 100% Renewable Energy Study (PR100) is a 2-year study by the U.S. Department of Energy's (DOE's) Grid Deployment Office and six national laboratories to comprehensively analyze stakeholder-driven pathways to Puerto Rico's clean energy future. In Year 1 of the study, the PR100 team rigorously modeled and analyzed scenarios that meet Puerto Rico's renewable energy targets and achieve short-term recovery goals and long-term energy resilience. This report, which summarizes PR100 progress in Year 1, provides considerations that can inform potential funding and implementation decisions by key federal and local agencies and stakeholders. The summary report follows the publication in July 2022 of a PR100 Six-Month Progress Update (in English and Spanish), as well as public webinars in February 2022 to kick off the study and in July 2022 to present the 6-month update. A final written report and web-based visuals will be published in late 2023. All publications and public events associated with the study will be available in Spanish and English. This report is also available in Spanish https://www.nrel.gov/docs/fy23osti/85144.pdf.

100%↗

TuFF internal WRAP for Rapid Pipeline Repair (TuFF iWRAP)

The goal of “TuFF internal WRAP for Rapid Pipeline Repair” (TuFF iWRAP) program was to develop a novel material system and placement process to fabricate structural pipe within the existing deteriorated pipelines without disruption of gas delivery. The team (University of Delaware – Center for Composite Materials (UD-CCM) and Plitzie Inc.) addressed this challenge by developing a new material feedstock and pipe in pipe (PIP) repair strategy. This allows the potential for significant cost reduction and has minimum operational impact on gas customers. The new robotic based placement design allows discontinuous placement of pipe sections creating a stand-alone structural liner within the legacy pipeline without the need for pipe shutdown. Here, the material is supplied using a tethered material feeding system and is placed and UV cured with the internal Wound Rapid Automated Placement (iWRAP) system. This provides maximum placement efficiency capable of traversing 90 angle bends in 12-inch pipe and overall design customization to meet pipe repair requirements (e.g., variable wall thickness, bridging gaps, etc.). UV-curable fiber reinforced composite material has been optimized to meet structural performance and placement/cure times. Superior strength and fatigue life has been demonstrated by improving fiber-matrix adhesion using new fiber sizing for UV resins. Rapid cure approaches using new liner and resins have been evaluated with industry. The appropriate design of the section joints has been developed and tested. We estimate coating time to be ~100 hours per mile enabling typical pipe repair within 1 week.

03 NATURAL GAS↗