Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “diagnosability”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,351 records · Page 75

Analysis of sensitivity and rapid hybridization of a multiplexed Microbial Detection Microarray

Microarrays have proven to be useful in rapid detection of many viruses and bacteria. Pathogen detection microarrays have been used to diagnose viral and bacterial infections in clinical samples and to evaluate the safety of biological drug materials. A multiplexed version of the Lawrence Livermore Microbial Detection Array (LLMDA) was developed and evaluated with minimum detectable concentrations for pure unamplified DNA viruses, along with mixtures of viral and bacterial DNA subjected to different whole genome amplification protocols. In addition the performance of the array was tested when hybridization time was reduced from 17 h to 1 h. The LLMDA was able to detect unamplified vaccinia virus DNA at a concentration of 14 fM, or 100,000 genome copies in 12 μL of sample. With amplification, positive identification was made with only 100 genome copies of input material. When tested against human stool samples from patients with acute gastroenteritis, the microarray detected common gastroenteritis viral and bacterial infections such as rotavirus and E. coli. Accurate detection was found but with a 4-fold drop in sensitivity for a 1 h compared to a 17 h hybridization. The array detected 2 ng (equivalent concentration of 15.6 fM) of labeled DNA from a virus with 1 h hybridization without any amplification, and was able to identify the components of a mixture of viruses and bacteria at species and in some cases strain level resolution. Sensitivity improved by three orders of magnitude with random whole genome amplification prior to hybridization; for instance, the array detected a DNA virus with only 20 fg or 100 genome copies as input. This multiplexed microarray is an efficient tool to analyze clinical and environmental samples for the presence of multiple viral and bacterial pathogens rapidly.

59 BASIC BIOLOGICAL SCIENCES↗

Identification of drug repurposing candidates for amyotrophic lateral sclerosis using electronic health records: a retrospective cohort study

Amyotrophic lateral sclerosis (ALS) is a progressive neurodegenerative disease with a life expectancy of only 3–5 years and few approved treatments. To identify drug repurposing candidates for the treatment of ALS, we analysed the electronic health records (EHRs) of a large cohort of military veterans with ALS. We analysed the EHRs of individuals in the US Veterans Health Administration (VHA) database who were diagnosed with ALS between Jan 1, 2009 and Dec 31, 2019 to assess medication effects. Individuals without recorded prescriptions after the date of diagnosis were excluded. Two sets of criteria were applied to ascertain exposure. Exposure criteria A were met if the dispense date or the end date of the medication was within 12 months of ALS diagnosis and the end date was at least 6 months after the dispense date. Exposure criteria B were met if there were at least two dispenses within 6 months before diagnosis and 12 months after diagnosis. Propensity score-matched control groups were generated on the basis of confounders included in the EHR, with methodology of potential outcomes used to infer treatment effects. The primary outcome was death. A standard Cox proportional hazards analysis was done to assess association with survival. Survival was defined as the time from diagnosis date recorded in the EHR to death reported in the Department for Veterans Affairs Vital Status File. Follow-up survival time was censored on Dec 31, 2020, for those alive on this date. Downstream protein targets of drugs with clinically significant effects were analysed using the protein–protein interaction networks-based algorithm PathFX. The EHRs of 11 003 individuals with ALS in the VHA database were appropriate for analysis. 162 medications with treatment groups of 30 or more individuals were identified. Among these 162 medications, 27 were associated with statistically significant changes (≥0·1) in the hazard ratio (HR) for death. 18 of the medications were associated with a reduced HR for death (prolonged survival), and nine were associated with an increased HR for death (reduced survival). Drugs associated with reduced HR included HMG-CoA reductase inhibitors (simvastatin, pravastatin, lovastatin, and atorvastatin), PDE5 inhibitors (vardenafil and sildenafil), and α-adrenergic antagonists (tamsulosin and terazosin). The medications associated with an increased HR were drugs used either in the management of clinical features of ALS associated with poor outcomes or in end-of-life care. PathFx analysis identified a complex of proteins interacting with several of the identified drugs. To our knowledge, this analysis is the largest EHR-based study for identifying drug repurposing candidates for ALS. We identified several drugs that warrant further assessment as therapeutic options in ALS, as well as a protein network complex that might serve as a therapeutic target for ALS.

Reimer, Richard J. [Stanford Univ., CA (United Sta↗

Towards controlled synthesis of 2D crystals by chemical vapor deposition (CVD)

We report the emergence of two-dimensional (2D) materials has captured the imagination of researchers since graphene was first exfoliated from graphite in 2004. Their exotic properties give rise to many exciting potential applications in advanced electronic, optoelectronic, energy and biomedical technologies. Scalable growth of high quality 2D materials is crucial for their adoption in technological applications the same way the arrival of high quality silicon single crystals was to the semiconductor industry. A huge amount of effort has been devoted to grow large-area, highly crystalline 2D crystals such as graphene and transition metal dichalcogenides (TMDs) through various methods. While CVD growth of wafer-scale monolayer graphene and TMDs has been demonstrated, considerable challenges still remain. In this perspective, we advocate for the focus on the crystal growth morphology as an underpinning for understanding, diagnosing and controlling the CVD process and environment for 2D material growth. Like snowflakes in nature, 2D crystals exhibit a rich variety of morphologies under different growth conditions. The mapping of crystal shapes in the growth parameter space “encodes” a wealth of information, the deciphering of which will lead to better understanding of the fundamental growth mechanism and materials properties. To this end, we envision a collective effort by the 2D materials community to establish the correlation between crystal shapes and the intrinsic thermodynamic and kinetic parameters for CVD reactions through integrated crystal growth experiment, database development and machine learning assisted predictive modeling, which will pave a robust path towards controlled synthesis of 2D materials and heterostructures.

36 MATERIALS SCIENCE↗

Dosimetric Comparison of Helical Tomotherapy and Linac-IMRT Treatment Plans for Head and Neck Cancer Patients

The rapid development and clinical implementation of external beam radiation treatment technologies continues. The existence of various commercially available technologies for intensity-modulated radiation therapy (IMRT) has stimulated interest in exploring the differential potential advantage one may have compared with another. Two such technologies, Hi-Art Helical Tomotherapy (HT) and conventional medical linear accelerator-based IMRT (LIMRT) have been shown to be particularly suitable for the treatment of head and neck cancers. In this study, 23 patients who were diagnosed with stages 3 or 4 head and neck cancers, without evidence of distance metastatic disease, were treated in our clinic. Treatment plans were developed for all patients simultaneously on the HT planning station and on the Pinnacle treatment planning system for step-and-shoot IMRT. Patients were treated only on the HT unit, with the LIMRT plan serving as a backup in case the HT system might not be available. All plans were approved for clinical use by a physician. The prescription was that patients receive at least 95% of the planning target volume (PTV), which is 66 Gy at 2.2 Gy per fraction. Several dosimetric parameters were computed: PTV dose coverage; PTV volume conformity index; the normalized total dose (NTD), where doses were converted to 2 Gy per fraction to organs at risk (OAR); and PTV dose homogeneity. Both planning systems satisfied our clinic's PTV prescription requirements. The results suggest that HT plans had, in general, slightly better dosimetric characteristics, especially regarding PTV dose homogeneity and normal tissue sparing. However, for both techniques, doses to OAR were well below the currently accepted normal tissue tolerances. Consequently, factors other than the dosimetric parameters studied here may have to be considered when making a choice between IMRT techniques.

61 RADIATION PROTECTION AND DOSIMETRY↗

Novel Use of the Contura for High Dose Rate Cranial Brachytherapy

A popular choice for treatment of recurrent gliomas was cranial brachytherapy using the GliaSite Radiation Therapy System. However, this device was taken off the market in late 2008, thus leaving a treatment void. This case study presents our experience treating a cranial lesion for the first time using a Contura multilumen, high-dose-rate (HDR) brachytherapy balloon applicator. The patient was a 47-year-old male who was diagnosed with a recurrent right frontal anaplastic oligodendroglioma. Previous radiosurgery made him a good candidate for brachytherapy. An intracavitary HDR balloon brachytherapy device (Contura) was placed in the resection cavity and treated with a single fraction of 20 Gy. The implant, treatment, and removal of the device were all completed without incident. Dosimetry of the device was excellent because the dose conformed very well to the target. V90, V100, V150, and V200 were 98.9%, 95.7%, 27.2, and 8.8 cc, respectively. This patient was treated successfully using the Contura multilumen balloon. Contura was originally designed for deployment in a postlumpectomy breast for treatment by accelerated partial breast irradiation. Being an intracavitary balloon device, its similarity to the GliaSite system makes it a viable replacement candidate. Multiple lumens in the device also make it possible to shape the dose delivered to the target, something not possible before with the GliaSite applicator.

61 RADIATION PROTECTION AND DOSIMETRY↗

Successful delivery of adjuvant external beam radiotherapy for ependymoma in a patient with Ondine's curse

Ondine's curse is a rare, potentially life-threatening disorder characterized by loss of automatic breathing during sleep and preserved voluntary breathing. It is seldom encountered in the radiotherapy clinic but can pose significant technical challenges and safety concerns in the delivery of a prescribed radiation course. We report a unique case of successful delivery of radiotherapy for ependymoma in a patient with Ondine's curse. A 53-year-old gentleman presented with vertigo when lying down. Brain magnetic resonance imaging revealed an enhancing mass in the floor of the fourth ventricle. He underwent maximal safe resection. Pathology revealed ependymoma. The patient was referred for radiotherapy. Computed tomography simulation was performed in supine position with 3-point thermoplastic mask immobilization. Sequential TomoTherapy plans were developed. At first scheduled treatment, shortly after mask placement, his arms went limp and he was unresponsive. Vitals showed oxygen saturation 83%, pulse 127, and blood pressure 172/97 mm Hg. He was diagnosed with Ondine's curse thought secondary to previous brainstem damage; the combination of lying flat and pressure from the mask was causing him to go into respiratory arrest. As supine positioning did not seem clinically advisable, he was simulated in prone position. A RapidArc plan and a back-up conformal plan were developed. Prescriptions were modified to meet conservative organs-at-risk constraints. Several strategies were used to minimize uncertainties in set-up reproducibility associated with prone positioning. He tolerated prone RapidArc treatments well. The report highlights the importance of applying practical patient safety and treatment planning/delivery strategies in the management of this challenging case.

61 RADIATION PROTECTION AND DOSIMETRY↗

Dosimetric advantages of intensity-modulated proton therapy for oropharyngeal cancer compared with intensity-modulated radiation: A case-matched control analysis

A potential advantage of intensity-modulated proton therapy (IMPT) over intensity-modulated (photon) radiation therapy (IMRT) in the treatment of oropharyngeal carcinoma (OPC) is lower radiation dose to several critical structures involved in the development of nausea and vomiting, mucositis, and dysphagia. The purpose of this study was to quantify doses to critical structures for patients with OPC treated with IMPT and compare those with doses on IMRT plans generated for the same patients and with a matched cohort of patients actually treated with IMRT. In this study, 25 patients newly diagnosed with OPC were treated with IMPT between 2011 and 2012. Comparison IMRT plans were generated for these patients and for additional IMRT-treated controls extracted from a database of patients with OPC treated between 2000 and 2009. Cases were matched based on the following criteria, in order: unilateral vs bilateral therapy, tonsil vs base of tongue primary, T-category, N-category, concurrent chemotherapy, induction chemotherapy, smoking status, sex, and age. Results showed that the mean doses to the anterior and posterior oral cavity, hard palate, larynx, mandible, and esophagus were significantly lower with IMPT than with IMRT comparison plans generated for the same cohort, as were doses to several central nervous system structures involved in the nausea and vomiting response. Similar differences were found when comparing dose to organs at risks (OARs) between the IMPT cohort and the case-matched IMRT cohort. In conclusion, these findings suggest that patients with OPC treated with IMPT may experience fewer and less severe side effects during therapy. This may be the result of decreased beam path toxicities with IMPT due to lower doses to several dysphagia, odynophagia, and nausea and vomiting–associated OARs. Further study is needed to evaluate differences in long-term disease control and chronic toxicity between patients with OPC treated with IMPT in comparison to those treated with IMRT.

61 RADIATION PROTECTION AND DOSIMETRY↗

Pencil beam scanning proton therapy vs rotational arc radiation therapy: A treatment planning comparison for postoperative oropharyngeal cancer

Patients diagnosed with head and neck cancer are traditionally treated with photon radiotherapy. Proton therapy is currently being used clinically and may potentially reduce treatment-related toxicities by minimizing the dose to normal organs in the treatment of postoperative oropharyngeal cancer. The finite range of protons has the potential to significantly reduce normal tissue toxicity compared to photon radiotherapy. Seven patients were planned with both proton and photon modalities. The planning goal for both modalities was achieving the prescribed dose to 95% of the planning target volume (PTV). Dose-volume histograms were compared in which all cases met the target coverage goals. Mean doses were significantly lower in the proton plans for the oral cavity (1771 cGy photon vs 293 cGy proton, p < 0.001), contralateral parotid (1796 cGy photon vs 1358 proton, p < 0.001), and the contralateral submandibular gland (3608 cGy photon vs 3251 cGy proton, p = 0.03). Average total integral dose was 9.1% lower in proton plans. The significant dosimetric sparing seen with proton therapy may lead to reduced side effects such as pain, weight loss, taste changes, and dry mouth. Prospective comparisons of protons vs photons for disease control, toxicity, and patient-reported outcomes are therefore warranted and currently being pursued.

61 RADIATION PROTECTION AND DOSIMETRY↗

Radiation-induced hypothyroidism in patients with breast cancer: a retrospective analysis of 243 cases

This study aims to estimate the incidence of hypothyroidism (HT) and to evaluate the predictors affecting the development of HT after radiotherapy (RT) for breast cancer, with a focus on radiation dose-volumetric parameters. Between 2009 and 2015, 243 patients undergoing RT for breast cancer were retrospectively analyzed. Free triiodothyronine (FT3), free thyroxin (FT4), and thyrotropin (TSH) were monitored before and after RT. The relation between the doses to thyroid gland (D{sub mean}, D{sub max}, D{sub min}), percentage of thyroid volume receiving > 10 Gy, 20 Gy, 30 Gy, 40 Gy, and 50 Gy (V10 to V50), absolute thyroid volume, and HT were analyzed. The risk of HT according to radiation fields and the other clinic factors were also evaluated. The median follow-up was 41 (range; 6 to 130) months. Sixty-seven percent of the patients received RT to the breast/chest wall and ipsilateral supraclavicular fossa. Of 243 patients, 51 (21%) were diagnosed with HT. The median time to the onset of HT was 27 (range; 5 to 64) months. There were no significant relationships observed between D{sub min} or V10 to V50 and HT. The surgery type, clinical stage, nodal status, RT field, D{sub mean}, and D{sub max} were statistically significant predictors for HT in univariate analysis. The D{sub mean} was the only prognostic factor predicting HT in multivariate analysis, and D{sub mean} > 21 Gy was a threshold value for the evolvement of HT. In this study, we present evidence that postoperative irradiation of patients with breast cancer may frequently lead to HT. Patients who have received RT for breast cancer, especially irradiation on the supraclavicular region, may require thyroid function screening after RT.

61 RADIATION PROTECTION AND DOSIMETRY↗

Study for reducing lung dose of upper thoracic esophageal cancer radiotherapy by auto-planning: volumetric-modulated arc therapy vs intensity-modulated radiation therapy

This study aimed to investigate the dosimetric differences and lung sparing between volumetric-modulated arc therapy (VMAT) and intensity-modulated radiation therapy (IMRT) in the treatment of upper thoracic esophageal cancer with T3N0M0 for preoperative radiotherapy by auto-planning (AP). Sixteen patient cases diagnosed with upper thoracic esophageal cancer T3N0M0 for preoperative radiotherapy were retrospectively studied, and 3 plans were generated for each patient: full arc VMAT AP plan with double arcs, partial arc VMAT AP plan with 6 partial arcs, and conventional IMRT AP plan. A simultaneous integrated boost with 2 levels was planned in all patients. Target coverage, organ at risk sparing, treatment parameters including monitor units and treatment time (TT) were evaluated. Wilcoxon signed-rank test was used to check for significant differences (p 20 ), 25 Gy (V{sub 25}), 30 Gy (V{sub 30}), 35 Gy (V{sub 35}), 40 Gy (V{sub 40}), and without increasing the value of V{sub 10}, V{sub 13}, and V{sub 15}. For V{sub 5} of total lung value, pVMAT was similar to aIMRT, and it was better than fVMAT. Both pVMAT and fVMAT improved the target dose coverage and significantly decreased maximum dose for the spinal cord, monitor unit, and TT. No significant difference was observed with respect to V{sub 10} and V{sub 15} of body. VMAT AP plan was a good option for treating upper thoracic esophageal cancer with T3N0M0, especially partial arc VMAT AP plan. It had the potential to effectively reduce lung dose in a shorter TT and with superior target coverage and dose homogeneity.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Cumulative dose of radiation therapy of hepatocellular carcinoma patients and its deterministic relation to radiation-induced liver disease

This study aimed to investigate the relationship between dose and radiation-induced liver disease (RILD) in patients with hepatocellular carcinoma (HCC) receiving 3-dimensional conformal radiotherapy (3DCRT). Twenty-three patients with HCC who received conventional fractionated 3DCRT, including 7 who were diagnosed with classic RILD, were enrolled in this retrospective investigation. Cone-beam computed tomography (CBCT) scans were acquired at the time of treatment for each patient. The beams from each patient's treatment plan were applied to each pretreatment CBCT (the modified CBCT or mCBCT) to construct the delivered dose distribution of the day considering inter-treatment anatomy changes. The daily doses were summed together with the help of deformable image registration (DIR) to obtain the adjusted cumulative dose (D{sub adjusted}). The dose changes to the normal liver between the original planned dose (D{sub plan}) and D{sub adjusted} were evaluated by V20, V30, V40, and the mean dose to normal liver (MDTNL). Univariate analysis was performed to identify the significant dose changes. Among the 23 patients, the liver V20, V30, V40, and MDTNL showed significant differences between D{sub plan} and D{sub adjusted}, with average values of these parameters increased by 4.1%, 4.7%, 4.5%, and 3.9 Gy, respectively (p adjusted . Determination of a reconstructed D{sub adjusted} using the mCBCT scans are more accurate in predicting RILD and has the potential to reduce the risk of RILD.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Evaluation of MLC leaf transmission on IMRT treatment plan quality of patients with advanced lung cancer

The purpose of this paper was to evaluate the impact of leaf treatment of multileaf collimator (MLC) in plan quality of intensity-modulated radiotherapy (IMRT) of patients with advanced lung cancer. Five MLCs with different leaf transmissions (0.01%, 0.5%, 1.2%, 1.8%, and 3%) were configured for an accelerator in a treatment planning system. Correspondingly, 5 treatment plans with the same optimization setting were created and evaluated quantitatively for each patient (11 patients total) who was diagnosed with advanced lung cancer. All of the 5 plans for each patient met the dose requirement for the planning treatment volumes (PTVs) and had similar target dose homogeneity and conformity. On average, the doses to selected organs were as follows: (1) V{sub 5}, V{sub 20}, and the mean dose of total lung; (2) the maximum and mean dose to spinal cord planning organ-at-risk volume (PRV); and (3) V{sub 30} and V{sub 40} of heart, decreased slightly when MLC transmission was decreased, but with no statistical differences. There is a clear grouping of plans having total quality score (S{sub D}) value, which is used to evaluate plan quality: (1) more than 1 (patient nos. 1 to 3, 5, and 8), and more than 2.5 (patient no. 6); (2) less than 1 (patient nos. 7 and 10); (3) around 1 (patient nos. 4, 9, and 11). As MLC transmission increased, overall S{sub D} values increased as well and plan dose requirement was harder to meet. The clinical requirements were violated increasingly as MLC transmission became large. Total S{sub D} with and without normal tissue (NT) showed similar results, with no statistically significant differences. Therefore, decrease of MLC transmission did have minimum impact on plan, and it improved target coverage and reduced normal tissue radiation slightly, with no statistical significance. Plan quality could not be significantly improved by MLC transmission reduction. However, lower MLC transmission may have advantages on lung sparing to low- and intermediate-dose exposure. Besides conventional fraction, hyperfraction, or stereotactic body radiotherapy (SBRT), the reduction on lung sparing is still essential because it is highly relevant to radiation pneumonitis (RP). It has potential to diminish incidence of RP and improve patient's quality of life after irradiation with lowered MLC transmission.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Exudate-based diabetic macular edema detection in fundus images using publicly available datasets

Diabetic macular edema (DME) is a common vision threatening complication of diabetic retinopathy. In a large scale screening environment DME can be assessed by detecting exudates (a type of bright lesions) in fundus images. In this work, we introduce a new methodology for diagnosis of DME using a novel set of features based on colour, wavelet decomposition and automatic lesion segmentation. These features are employed to train a classifier able to automatically diagnose DME through the presence of exudation. We present a new publicly available dataset with ground-truth data containing 169 patients from various ethnic groups and levels of DME. This and other two publicly available datasets are employed to evaluate our algorithm. We are able to achieve diagnosis performance comparable to retina experts on the MESSIDOR (an independently labelled dataset with 1200 images) with cross-dataset testing (e.g., the classifier was trained on an independent dataset and tested on MESSIDOR). Our algorithm obtained an AUC between 0.88 and 0.94 depending on the dataset/features used. Additionally, it does not need ground truth at lesion level to reject false positives and is computationally efficient, as it generates a diagnosis on an average of 4.4 s (9.3 s, considering the optic nerve localization) per image on an 2.6 GHz platform with an unoptimized Matlab implementation.

59 BASIC BIOLOGICAL SCIENCES↗

Electrochemo-mechanics unlocks hidden dynamics of lithium plating under stacking pressure

Understanding and mitigating lithium plating remains one of the most pressing challenges in advancing the safety and longevity of lithium-ion batteries (LIBs). Here, we present a novel integrative framework that combines in-operando swelling force measurements with a physics-based electro-chemo-mechanical model to uncover previously inaccessible insights into lithium plating dynamics under mechanical constraints. Unlike existing approaches that focus primarily on electrochemical signatures, our approach captures the coupled mechanical responses of commercial pouch cells during cycling, revealing how mechanical constraints fundamentally alter degradation pathways. We demonstrate that the use of a moderate stacking pressure suppresses lithium plating and enhances lithium stripping. This mechanically driven structural effect, coupled with the electrochemical process, significantly extends the linear aging regime in LIBs. Intriguingly, intermittent capacity recovery events that were observed during the battery cycling suggest dynamic lithium reactivation, a phenomenon rarely captured in real-time. This study pioneers a stress-aware methodology for diagnosing and managing lithium plating, establishing a new paradigm for real-time battery health monitoring. The findings offer transformative implications for the design of durable, high-performance LIB systems, opening new avenues for intelligent control strategies in battery management systems.

Bhowmick, Amit↗

Persistent urinary metabolic signatures in children with type 1 diabetes

There are an estimated 3.7 million people with undiagnosed type 1 diabetes (T1D), living primarily in poor areas of the globe. Therefore, there is a need for non-invasive, affordable tests to provide accurate diagnosis despite the time post-disease onset and fasting state. Here, we studied persistent urinary T1D biomarkers that can be used to develop such tests. Here, we analyzed the urine metabolomes of three independent cohorts of samples collected within 48 h (from Indiana University), and 1 year (from University of Colorado) and 1–10 years (6 years in average) (from Children’s National Medical Center) post-diagnosis. Samples were submitted to gas chromatography-mass spectrometry and machine learning an0alyses to determine diagnostic metabolite panels. The data were also mapped into a metabolic pathway to understand persistently regulated processes in T1D. Seven metabolites showed consistent increases in all three cohorts: d-glucose, d-mannose, myo-inositol, 3-hydroxyisobutyric acid, gluconolactone, d-gluconic acid, and d-glucuronic acid. A combination of machine learning analysis and metabolite ratios as biomarker candidates diagnosed T1D with high sensitivity and specificity across different cohorts and times. Mapping the regulated metabolites into a pathway showed impairment in glycolysis and overflow of glucose towards other pathways in subjects with T1D that was persistent over time. We identified and cross-validated highly specific and sensitive urinary biomarkers. This opens opportunities to develop affordable, robust, and non-invasive tests. The results also show that most of the biomarkers were signatures of dysregulated glucose metabolism.

Type 1 diabetes↗

Intrinsic resolution limits of monolithic organic scintillators for use in rep-rated proton imaging

Rep-rated diagnostics are a necessity for present and future laser facilities focused on the study of high-energy-density (HED) phenomena. Electromagnetic fields in HED systems are of particular interest to the community, but are inherently difficult to diagnose due to the high mass-densities involved. By utilizing high-energy protons that penetrate through dense plasmas, fields may be visualized by detecting variations in proton fluence caused by the Lorenz interaction of the protons with the field. Typical detecting media used for proton imaging are single-use and do not scale well to rep-rated operation. We propose the use of a scintillator-based detector and characterize the energy and spatial responses to demonstrate its feasibility as a viable option for rep-rated proton imaging and other diagnostics.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Superlattice-enhanced silicon soft X-ray and charged particle detectors with nanosecond time response

Here, silicon detectors are an essential measurement tool for Inertial Confinement Fusion and High-Energy-Density Physics Applications, where temporal response of the order of nanoseconds is essential. Soft X-rays (<1 keV), Ultraviolet light, and low-energy electrons (<10 keV) can provide essential information in diagnosing rapidly changing plasma conditions, but reducing the detector dead layer is essential to improving detector response for these shallowly absorbed particles. This paper details a study of silicon detector surface preparation methods such as ion implant parameters, and the addition of a quantum 2D superlattice, to produce fast detectors that are highly sensitive to shallowly absorbed radiation. Measurements of visible light quantum efficiency, electron responsivity, and pulsed x-ray response indicate that detectors with a 2-layer superlattice enjoy a significant benefit over equivalent detectors using an ion implant at the illuminated surface.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurements of temporally- and spatially-resolved neutron production in a sheared-flow stabilized Z-pinch

A novel approach using multiple scintillator detectors is applied to measure temporally- and spatially-resolved neutron production in the Fusion Z-pinch Experiment (FuZE) device, a Sheared-Flow Stabilized (SFS) Z-pinch. Diagnosing neutron production from FuZE is important for determining if fusion is thermonuclear and whether the FuZE device can be scaled toward reactor conditions. Absolute yields of up to 2 × 10 5 neutrons per discharge are measured with calibrated plastic scintillator detectors operating in pulse-counting mode. Neutron emission durations of up to ~8 μs are inferred by recording the time difference between the first and last pulses for each discharge. Multiple scintillator detectors located at different positions with respect to the fusing plasma are used to demonstrate that the axial extent of the neutron producing region is comparable to the device volume. Scintillator detectors are well-suited as neutron diagnostics for FuZE and other plasma devices with similar yields and emission durations. Increasing the neutron yield, duration, and volume of the neutron emitting region within the plasma column are significant experimental objectives for FuZE.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗