Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “corrected data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,351 records · Page 75

Probabilistic assessment of cloud fraction using Bayesian blending of independent datasets: Feasibility study of a new method

We describe and evaluate a novel method to blend two observed cloud fraction (CF) datasets through Bayesian posterior estimation. The research reported here is a feasibility study designed to explore the method. In this proof‐of‐concept study, we illustrate the approach using specific observational datasets from the U. S. Department of Energy Atmospheric Radiation Measurement Program's Southern Great Plains site in the central United States, but the method is quite general and is readily applicable to other datasets. The total sky image (TSI) camera observations are used to determine the prior distribution. A regression model and the active remote sensing of clouds (ARSCL) radar/lidar observations are used to determine the likelihood function. The posterior estimate is a probability density function (pdf) of the CF whose mean is taken to be the optimal blend of the two observations. The data at hourly, daily, 5‐day, monthly, and annual time scales are considered. Some physical and probabilistic properties of the CFs are explored from radar/lidar, camera, and satellite observations and from simulations using the Community Atmosphere Model (CAM5). Our results imply that (a) the Beta distribution is a reasonable model for CF for both short‐ and long‐time means, the 5‐day data are skewed right, and the annual data are almost normally distributed, and (b) the Bayesian method developed successfully yields a pdf of CF, rather than a deterministic CF value, and it is feasible to blend the TSI and ARSCL data with a capability for bias correction.

58 GEOSCIENCES↗

Utah FORGE: Wells Wow2 and Wow3 Groundwater Monitoring Data

This dataset includes ground water level data for Utah FORGE Phase 2c ground water monitoring wells Wow2 and Wow3. The readme file explains the fields contained in the included Excel spreadsheet and contains the coordinates for the wells. The Excel spreadsheet contains raw data taken directly from downhole transducers and includes fields labeled Date, Time, LEVEL, and TEMPERATURE.

15 GEOTHERMAL ENERGY↗

Assessment of BSRN radiation records for the computation of monthly means

The accuracy of the Baseline Surface Radiation Network (BSRN) radiation monthly averages are assessed by investigating data gap frequency due to missing or discarded high time resolution data. The monthly statistics, especially means are considered to be important and useful values for climate research, model performance evaluations and for assessing the quality of satellite computations. The study investigates the spread in different algorithms that have been applied for the computation of monthly means from minute values. We found that a substantial fraction of the radiation fluxes observed at BSRN sites is either missing or flagged as questionable. The percentage of missing data is 4.4%, 13.0%, and 6.5% for global radiation, direct shortwave radiation, and downwelling longwave radiation, respectively. Most flagged data in the shortwave are due to nighttime instrumental noise and can reasonably be set to zero after correcting for thermal offsets in the daytime data. The paper reveals that the computation of monthly means from 1-minute observations distinctly depends on the selected method. The intra-method difference generally increases with an increasing fraction of missing data. The study demonstrates that the handling of flagged data clearly impacts on monthly mean estimates obtained with different methods. We showed that the spread of monthly shortwave fluxes are generally clearly higher than for downwelling longwave radiation. Overall, BSRN observation provide sufficient accuracy and completeness for reliable estimates of monthly mean values. However, we should aim at further increasing the data quality by reducing the data gap frequency and the number of outliers. The authors suggest using a standardized method for the computation of monthly means in order to avoid a mismatch of published monthly mean radiation fluxes from BSRN.

54 ENVIRONMENTAL SCIENCES↗

The Midlatitude Continental Convective Clouds Experiment (MC3E) sounding network: operations, processing and analysis

The Midlatitude Continental Convective Clouds Experiment (MC3E) took place during the spring of 2011 centered in north-central Oklahoma, USA. The main goal of this field campaign was to capture the dynamical and microphysical characteristics of precipitating convective systems in the US Central Plains. A major component of the campaign was a six-site radiosonde array designed to capture the large-scale variability of the atmospheric state with the intent of deriving model forcing data sets. Over the course of the 46-day MC3E campaign, a total of 1362 radiosondes were launched from the enhanced sonde network. This manuscript provides details on the instrumentation used as part of the sounding array, the data processing activities including quality checks and humidity bias corrections and an analysis of the impacts of bias correction and algorithm assumptions on the determination of convective levels and indices. It is found that corrections for known radiosonde humidity biases and assumptions regarding the characteristics of the surface convective parcel result in significant differences in the derived values of convective levels and indices in many soundings. In addition, the impact of including the humidity corrections and quality controls on the thermodynamic profiles that are used in the derivation of a large-scale model forcing data set are investigated. The results show a significant impact on the derived large-scale vertical velocity field illustrating the importance of addressing these humidity biases.

54 ENVIRONMENTAL SCIENCES↗

Accurate CI-MBPT calculation of radiative lifetimes and transition probabilities of neutral lanthanum (La I) odd states with J = 3/2

In this work, an accurate calculation of radiative lifetimes and transition probabilities of the first 21 odd states with a total angular momentum J = 3/2 was performed for La I using configuration-interaction many-body perturbation theory (CI-MBPT). A technique to obtain correct transition amplitudes was devised for pairs of states with substantial mixing that improved the theoretical accuracy. The results were compared to known experimental and theoretical data for the considered transitions. It has been shown that the transition data calculated with CI-MBPT and with corrections for pairs of mixed states are in good agreement with the latest experimental data of Den Hartog et al, 2015 J. Phys. B: At. Mol. Phys. 48, 155 001, better than other theoretical results. The transition data can find many applications in astrophysics, and the CI-MBPT formalism with mixing correction is applicable to other atoms similar to or more complex than La I.

36 MATERIALS SCIENCE↗

Accelerated acquisition of tagged MRI for cardiac motion correction in simultaneous PET-MR: Phantom and patient studies

Purpose: Degradation of image quality caused by cardiac and respiratory motions hampers the diagnostic quality of cardiac PET. It has been shown that improved diagnostic accuracy of myocardial defect can be achieved by tagged MR (tMR) based PET motion correction using simultaneous PET-MR. However, one major hurdle for the adoption of tMR-based PET motion correction in the PET-MR routine is the long acquisition time needed for the collection of fully sampled tMR data. In this work, the authors propose an accelerated tMR acquisition strategy using parallel imaging and/or compressed sensing and assess the impact on the tMR-based motion corrected PET using phantom and patient data. Methods: Fully sampled tMR data were acquired simultaneously with PET list-mode data on two simultaneous PET-MR scanners for a cardiac phantom and a patient. Parallel imaging and compressed sensing were retrospectively performed by GRAPPA and kt-FOCUSS algorithms with various acceleration factors. Motion fields were estimated using nonrigid B-spline image registration from both the accelerated and fully sampled tMR images. The motion fields were incorporated into a motion corrected ordered subset expectation maximization reconstruction algorithm with motion-dependent attenuation correction. Results: Although tMR acceleration introduced image artifacts into the tMR images for both phantom and patient data, motion corrected PET images yielded similar image quality as those obtained using the fully sampled tMR images for low to moderate acceleration factors (<4). Quantitative analysis of myocardial defect contrast over ten independent noise realizations showed similar results. It was further observed that although the image quality of the motion corrected PET images deteriorates for high acceleration factors, the images were still superior to the images reconstructed without motion correction. Conclusions: Accelerated tMR images obtained with more than 4 times acceleration can still provide relatively accurate motion fields and yield tMR-based motion corrected PET images with similar image quality as those reconstructed using fully sampled tMR data. The reduction of tMR acquisition time makes it more compatible with routine clinical cardiac PET-MR studies.

60 APPLIED LIFE SCIENCES↗

Lithium-Ion Battery Diagnostics Using Electrochemical Impedance via Machine-Learning

Diagnosing battery states such as health, state-of-charge, or temperature is crucial for ensuring the safety and reliability of electrochemical energy storage systems. While some states, such as temperature, may be measured using cheap sensors, accurate diagnosis of battery health metrics usually requires time-consuming performance measurements, making them infeasible for use in real-world operation. These health metrics can be measured during lab-testing and then estimated on-line using predictive life models or via state observer algorithms such as Kalman filters, but these predictive methods should be supplemented by actual measurement of battery health whenever possible to ensure reliability. Rapid measurement of battery health may be done by various types of fast diagnostic techniques such as electrochemical impedance spectroscopy (EIS), which can be performed in only a few minutes and require only a fraction of the energy and power needed for a full charge and discharge measurement. But there is a substantial challenge for estimating battery health using EIS data, as EIS is sensitive to cell temperature, state-of-charge, current, and resting time in addition to health. Thus, utilizing EIS data to predict battery capacity requires correcting for all these additional variables, a task that is extremely difficult to handle analytically. This talk utilizes machine-learning methods to estimate the effectiveness of battery capacity prediction from EIS data, leveraging a data set of hundreds of EIS measurements recorded at varying temperature and state-of-charge throughout a 500-day aging study of 32 commercial, large-format NMC-Graphite lithium-ion batteries. Using EIS as input to machine-learning models is complicated by the nonlinear response of impedance to battery health, temperature, and state-of-charge, as well as the collinearity between the impedance response at neighboring frequencies, which can easily lead to overfit models. To train robust models, features from EIS data need to be extracted from the data or some subset of critical frequencies selected. Many approaches for extracting and selecting features from EIS data from electrochemical analysis and machine-learning fields were identified for analysis: using the entire raw spectra; selection of one, two, or many frequencies from the entire spectra; selecting interesting points from the EIS measurement using domain knowledge; fitting EIS with an equivalent-circuit model; calculating statistics on the raw impedance values; and reducing the dimensionality of the data using unsupervised linear (principal component analysis) and non-linear (uniform manifold approximation and projection) methods. These approaches were rigorously compared using a machine-learning pipeline approach, training linear, Gaussian process, and random forest regression models and quantifying performance using cross-validation as well as a held-out test set. An artificial neural network model trained on the raw spectra was also tested. Promising pipelines were fine-tuned via Bayesian hyperparameter optimization using cross-validation loss and training with class-specific weights to counter data set imbalance. The most reliable method for utilizing impedance in this work was the selection of two optimal frequencies through an exhaustive search, resulting in about 2% mean absolute error on test data for both Gaussian process and random forest model architectures. Interrogation of a variety of models reveals critical frequencies of 100 Hz and 103 Hz for this data set, though the optimal set of frequencies is not necessarily intuitive, i.e., the best performing models are not simply those that use impedance at frequencies that have the highest correlation to the relative discharge capacity. The best performing model is an ensemble model, which is able to predict battery capacity with 1.9% mean absolute error for unseen cells using impedance recorded at a variety of temperatures and states-of-charge.

battery↗

Methods for a blind analysis of isobar data collected by the STAR collaboration

In 2018, the STAR collaboration collected data from $_{44}^{96}{\mathrm{Ru}}+_{44}^{96}{\mathrm{Ru}}$ and $_{40}^{96}{\mathrm{Zr}}+_{40}^{96}{\mathrm{Zr}}$ at $\sqrt{s_\text {NN}}=200$ GeV to search for the presence of the chiral magnetic effect in collisions of nuclei. The isobar collision species alternated frequently between $_{44}^{96}{\mathrm{Ru}}+_{44}^{96}{\mathrm{Ru}}$ and $_{40}^{96}{\mathrm{Zr}}+_{40}^{96}{\mathrm{Zr}}$ . In order to conduct blind analyses of studies related to the chiral magnetic effect in these isobar data, STAR developed a three-step blind analysis procedure. Analysts are initially provided a “reference sample” of data, comprised of a mix of events from the two species, the order of which respects time-dependent changes in run conditions. After tuning analysis codes and performing time-dependent quality assurance on the reference sample, analysts are provided a species-blind sample suitable for calculating efficiencies and corrections for individual $\approx 30$-min data-taking runs. For this sample, species-specific information is disguised, but individual output files contain data from a single isobar species. Only run-by-run corrections and code alteration subsequent to these corrections are allowed at this stage. Following these modifications, the “frozen” code is passed over the fully un-blind data, completing the blind analysis. As a check of the feasibility of the blind analysis procedure, analysts completed a “mock data challenge,” analyzing data from Au + Au collisions at $\sqrt{s_\text {NN}}=27$ GeV, collected in 2018. The Au + Au data were prepared in the same manner intended for the isobar blind data. Finally, the details of the blind analysis procedure and results from the mock data challenge are presented.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Electromagnetic form factors of the nucleon: New fit and analysis of uncertainties

Electromagnetic form factors of proton and neutron, obtained from a new fit of data, are presented. The proton form factors are obtained from a simultaneous fit to the ratio {mu}{sub p}G{sub Ep}/G{sub Mp} determined from polarization transfer measurements and to ep elastic cross section data. Phenomenological two-photon exchange corrections are taken into account. The present fit for protons was performed in the kinematical region Q{sup 2} is an element of (0,6) GeV{sup 2}. For both protons and neutrons we use the latest available data. For all form factors, the uncertainties and correlations of form factor parameters are investigated with the {chi}{sup 2} method.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Microbial Community Analysis with Ribosomal Gene Fragments from Shotgun Metagenomes

Shotgun metagenomic sequencing does not depend on gene-targeted primers or PCR amplification; thus, it is not affected by primer bias or chimeras. However, searching rRNA genes from large shotgun Illumina data sets is computationally expensive, and no approach exists for unsupervised community analysis of small-subunit (SSU) rRNA gene fragments retrieved from shotgun data. We present a pipeline, SSUsearch, to achieve the faster identification of short-subunit rRNA gene fragments and enabled unsupervised community analysis with shotgun data. It also includes classification and copy number correction, and the output can be used by traditional amplicon analysis platforms. Shotgun metagenome data using this pipeline yielded higher diversity estimates than amplicon data but retained the grouping of samples in ordination analyses. We applied this pipeline to soil samples with paired shotgun and amplicon data and confirmed bias against Verrucomicrobia in a commonly used V6-V8 primer set, as well as discovering likely bias against Actinobacteria and for Verrucomicrobia in a commonly used V4 primer set. In conclusion, this pipeline can utilize all variable regions in SSU rRNA and also can be applied to large-subunit (LSU) rRNA genes for confirmation of community structure.

59 BASIC BIOLOGICAL SCIENCES↗

Models of isospin breaking in the pion form factor: Consequences for the determination of {pi}{sub {rho}}{sub {omega}}(m{sub {rho}}{sup 2}) and (g-2){sub {mu}}/2

We study the implications of several recent high-precision measurements of the pion form factor in the region of the {rho}-{omega} interference shoulder for (i) the extraction of the {rho}-{omega} mixing matrix element, {pi}{sub {rho}}{sub {omega}}(m{sub {rho}}{sup 2}), and (ii) the evaluation of the isospin-breaking correction needed to incorporate hadronic {tau} decay data into the determination of the standard model expectation for the leading order hadronic contribution, [a{sub {mu}}]{sub had}{sup LO}, to the anomalous magnetic moment of the muon, focussing, in the latter case, on the model dependence of the {rho}-{omega} mixing component of the isospin-breaking correction. We consider a range of different models for the broad {rho} contribution to the e{sup +}e{sup -}{yields}{pi}{pi} amplitude, applying these models to each experimental data set, and find that the model dependence of the {rho}-{omega} mixing correction is significantly larger than the uncertainty induced by experimental errors for any individual model. We also find that, for each such model, the recent data allows one to separate {rho}-{omega} mixing and direct {omega}{yields}{pi}{pi} coupling contributions to the amplitude, and hence to obtain a reasonably precise extraction of {pi}{sub {rho}}{sub {omega}}(m{sub {rho}}{sup 2}), uncontaminated by direct {omega}{yields}{pi}{pi} coupling effects, for use in meson-exchange model calculations of charge symmetry breaking in NN scattering.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Cosmological constraints from the Planck cluster catalogue with DES shear profiles and Chandra observations

We present cosmological constraints from the Planck PSZ2 cosmological cluster sample, using weak-lensing shear profiles from Dark Energy Survey (DES) data and X-ray observations from the Chandra telescope for the mass calibration. We compute hydrostatic mass estimates for all clusters in the PSZ2 sample with a scaling relation between their Sunyaev-Zeldovich signal and X-ray derived hydrostatic mass, calibrated with the Chandra data. We introduce a method to correct these masses with a hydrostatic mass bias using shear profiles from wide-field galaxy surveys. We simultaneously fit the number counts of the PSZ2 sample and the mass calibration with the DES data, finding $Ω_\text{m}=0.312^{+0.018}_{-0.024}$, $σ_8=0.777\pm 0.024$, $S_8\equiv σ_8 \sqrt{Ω_\text{m} / 0.3}=0.791^{+0.023}_{-0.021}$, and $(1-b)=0.844^{+0.055}_{-0.062}$ for our baseline analysis when combined with BAO data. When considering a hydrostatic mass bias evolving with mass, we find $Ω_\text{m}=0.353^{+0.025}_{-0.031}$, $σ_8=0.751\pm 0.023$, and $S_8=0.814^{+0.019}_{-0.020}$. We verify the robustness of our results by exploring a variety of analysis settings, with a particular focus on the definition of the halo centre used for the extraction of shear profiles. We compare our results with a number of other analyses, in particular two recent analyses of cluster samples obtained from SPT and eROSITA data that share the same mass calibration data set. We find that our results are in overall agreement with most late-time probes, in very mild tension with CMB results (1.6$σ$), and in significant tension with results from eROSITA clusters (2.9$σ$). We confirm that our mass calibration is consistent with the eROSITA analysis by comparing masses for clusters present in both Planck and eROSITA samples, eliminating it as a potential cause of tension.

Aymerich, G. [Orsay, IAS; AIM, Saclay] (ORCID:0009↗

Anomalous behavior in high-pressure carbonaceous sulfur hydride

A new experimental study reported behavior in a high-pressure carbon-sulfur-hydrogen system that has been interpreted by the authors as superconductivity at room temperature. The sudden change of electrical resistance at a critical temperature and the change of the R vs. T behavior with an applied magnetic field point to superconductivity. This is a very exciting study in one of the most important areas of science, hence, it is crucial for the community to investigate these findings and hopefully reproduce these results. In this paper, we present calculations that expand upon the arguments put forth, and offer some speculations about physical mechanisms that might explain the observed data. Here, we show that there are errors in the analysis presented in the experimental paper, and with the correct analysis, the reported R vs. T data significantly deviate from the expected behavior. In particular, the extremely sharp change in resistance at the superconducting transition is not consistent with a strongly type II superconductor.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Efficient data reduction for time-of-flight neutron scattering experiments on single crystals

Event-mode data collection presents remarkable new opportunities for time-of-flight neutron scattering studies of collective excitations, diffuse scattering from short-range atomic and magnetic structures, and neutron crystallography. In these experiments, large volumes of the reciprocal space are surveyed, often using different wavelengths and counting times. These data then have to be added together, with accurate propagation of the counting errors. This paper presents a statistically correct way of adding and histogramming the data for single-crystal time-of-flight neutron scattering measurements. In order to gain a broader community acceptance, particular attention is given to improving the efficiency of calculations.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Implementation of a level 1 trigger system using high speed serial (VXS) techniques for the 12GeV high luminosity experimental programs at Thomas Jefferson National Accelerator Facility

We will demonstrate a hardware and firmware solution for a complete fully pipelined multi-crate trigger system that takes advantage of the elegant high speed VXS serial extensions for VME. This trigger system includes three sections starting with the front end crate trigger processor (CTP), a global Sub-System Processor (SSP) and a Trigger Supervisor that manages the timing, synchronization and front end event readout. Within a front end crate, trigger information is gathered from each 16 Channel, 12 bit Flash ADC module at 4 nS intervals via the VXS backplane, to a Crate Trigger Processor (CTP). Each Crate Trigger Processor receives these 500 MB/S VXS links from the 16 FADC-250 modules, aligns skewed data inherent of Aurora protocol, and performs real time crate level trigger algorithms. The algorithm results are encoded using a Reed-Solomon technique and transmission of this Level 1 trigger data is sent to the SSP using a multi-fiber link. The multi-fiber link achieves an aggregate trigger data transfer rate to the global trigger at 8 Gb/s. The SSP receives and decodes Reed-Solomon error correcting transmission from each crate, aligns the data, and performs the global level trigger algorithms. The entire trigger system is synchronous and operates at 250 MHz with the Trigger Supervisor managing not only the front end event readout, but also the distribution of the critical timing clocks, synchronization signals, and the global trigger signals to each front end readout crate. These signals are distributed to the front end crates on a separate fiber link and each crate is synchronized using a unique encoding scheme to guarantee that each front end crate is synchronous with a fixed latency, independent of the distance between each crate. The overall trigger signal latency is <3 uS, and the proposed 12GeV experiments at Jefferson Lab require up to 200KHz Level 1 trigger rate.

43 PARTICLE ACCELERATORS↗

A Prescription for List-Mode Data Processing Conventions

There are a variety of algorithmic approaches available to process list-mode pulse streams to produce multiplicity histograms for subsequent analysis. In the development of the INCC v6.0 code to include the processing of this data format, we have noted inconsistencies in the “processed time” between the various approaches. The processed time, tp, is the time interval over which the recorded pulses are analyzed to construct multiplicity histograms. This is the time interval that is used to convert measured counts into count rates. The observed inconsistencies in tp impact the reported count rate information and the determination of the error-values associated with the derived singles, doubles, and triples counting rates. This issue is particularly important in low count-rate environments. In this report we will present a prescription for the processing of list-mode counting data that produces values that are both correct and consistent with traditional shift-register technologies. It is our objective to define conventions for list mode data processing to ensure that the results are physically valid and numerically aligned with the results from shift-register electronics.

List mode↗

Jet energy measurement and its systematic uncertainty in proton–proton collisions at √s = 7 TeV with the ATLAS detector

The jet energy scale (JES) and its systematic uncertainty are determined for jets measured with the ATLAS detector using proton–proton collision data with a centre-of-mass energy of \(\sqrt{s}=7\) TeV corresponding to an integrated luminosity of \(4.7\) \(\,\,\text{ fb }^{-1}\). Jets are reconstructed from energy deposits forming topological clusters of calorimeter cells using the anti-\(k_{t}\) algorithm with distance parameters \(R=0.4\) or \(R=0.6\), and are calibrated using MC simulations. A residual JES correction is applied to account for differences between data and MC simulations. This correction and its systematic uncertainty are estimated using a combination of in situ techniques exploiting the transverse momentum balance between a jet and a reference object such as a photon or a \(Z\) boson, for \({20} \le p_{\mathrm {T}}^\mathrm {jet}<{1000}\, ~\mathrm{GeV }\) and pseudorapidities \(|\eta |<{4.5}\). The effect of multiple proton–proton interactions is corrected for, and an uncertainty is evaluated using in situ techniques. The smallest JES uncertainty of less than 1 % is found in the central calorimeter region (\(|\eta |<{1.2}\)) for jets with \({55} \le p_{\mathrm {T}}^\mathrm {jet}<{500}\, ~\mathrm{GeV }\). For central jets at lower \(p_{\mathrm {T}}\), the uncertainty is about 3 %. A consistent JES estimate is found using measurements of the calorimeter response of single hadrons in proton–proton collisions and test-beam data, which also provide the estimate for \(p_{\mathrm {T}}^\mathrm {jet}> 1\) TeV. The calibration of forward jets is derived from dijet \(p_{\mathrm {T}}\) balance measurements. The resulting uncertainty reaches its largest value of 6 % for low-\(p_{\mathrm {T}}\) jets at \(|\eta |=4.5\). In addition, JES uncertainties due to specific event topologies, such as close-by jets or selections of event samples with an enhanced content of jets originating from light quarks or gluons, are also discussed. The magnitude of these uncertainties depends on the event sample used in a given physics analysis, but typically amounts to 0.5–3 %.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Waste Form Release Data Package for the 2005 Integrated Disposal Facility Performance Assessment. Erratum

This report refers to or contains K g values for glasses LAWA44, LAWB45 and LAWC22 affected by calculations errors as identified by Papathanassiu et al. (2011). The corrected K g values are reported in an erratum included in the revised version of the original report. The revised report can be referenced as follows: Pierce E. M. et al. (2004) Waste Form Release Data Package for the 2005 Integrated Disposal Facility Performance Assessment. PNNL-14805 Rev. 0 Erratum. Pacific Northwest National Laboratory, Richland, WA, USA.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗