Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “calibration methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,351 records · Page 75

Characterizations of the Earth Radiation Budget Experiment (ERBE) scanning radiometers

NASA's Earth Radiation Budget Experiment employs the Earth Radiation Budget Satellite and the NOAA 9 and 10 spacecraft to obtain absolute measurements of incoming solar radiation, shortwave earth-reflected solar radiation, and longwave earth-emitted radiation, using both scanning and nonscanning radiometers. Each of the three remote-sensing spacecraft carry narrow FOV scanning radiometers whose detection sensors are thermistor bolometers. Attention is presently given to the calibration models and methods employed in characterizing the scanning radiometers' output signals; the design features of the scanners and flight calibration systems are presented.

Lee, Robert B., III↗

Comparison of Two Load Prediction Methods for Strain-Gage Balances

Data from a five-component semi-span balance is used to perform a systematic comparison of the load prediction accuracy of two load prediction methods. Both methods independently obtain the load prediction equations from multivariate least squares fits of balance calibration data. The first method is called the Non-Iterative Method. This approach directly uses regression models of the individual load components of a balance for the load prediction. The second method is called the Iterative Method. This alternate approach uses a load iteration equation for the load prediction that is constructed from the regression coefficients of the gage outputs of the balance. Basic characteristics of the two methods are reviewed. Afterwards, both methods are applied to calibration, check load, and wind tunnel test data of a five-component semi-span balance. Selected analysis results are compared. These comparisons confirm that the accuracy of the two methods is the same for all practical purposes.

strain-gage balance↗

Effect of cantilever geometry on the optical lever sensitivities and thermal noise method of the atomic force microscope

Calibration of the optical lever sensitivities of atomic force microscope (AFM) cantilevers is especially important for determining the force in AFM measurements. These sensitivities depend critically on the cantilever mode used and are known to differ for static and dynamic measurements. Here, we calculate the ratio of the dynamic and static sensitivities for several common AFM cantilevers, whose shapes vary considerably, and experimentally verify these results. The dynamic-to-static optical lever sensitivity ratio is found to range from 1.09 to 1.41 for the cantilevers studied – in stark contrast to the constant value of 1.09 used widely in current calibration studies. This analysis shows that accuracy of the thermal noise method for the static spring constant is strongly dependent on cantilever geometry – neglect of these dynamic-to-static factors can induce errors exceeding 100%. We also discuss a simple experimental approach to non-invasively and simultaneously determine the dynamic and static spring constants and optical lever sensitivities of cantilevers of arbitrary shape, which is applicable to all AFM platforms that have the thermal noise method for spring constant calibration.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Assessment and Calibration of a Crimp Tool Equipped with Ultrasonic Analysis Features

A method is provided for calibrating ultrasonic signals passed through a crimp formed with respect to a deformable body via an ultrasonically-equipped crimp tool (UECT). The UECT verifies a crimp quality using the ultrasonic signals. The method includes forming the crimp, transmitting a first signal, e.g., a pulse, to a first transducer of the UECT, and converting the first signal, using the first transducer, into a second signal which defines an ultrasonic pulse. This pulse is transmitted through the UECT into the crimp. A second transducer converts the second signal into a third signal, which may be further conditioned, and the ultrasonic signals are calibrated using the third signal or its conditioned variant. An apparatus for calibrating the ultrasonic signals includes a pulse module (PM) electrically connected to the first and second transducers, and an oscilloscope or display electrically connected to the PM for analyzing an electrical output signal therefrom.

Yost, William T.↗

Deriving New Mixing Ratios for Venus Atmospheric Gases Using Data From the Pioneer Venus Large Probe Neutral Mass Spectrometer

We present the first published method to convert data obtained by the Pioneer Venus Large Probe Neutral Mass Spectrometer (LNMS) into units of mixing ratio (ppm) and volume percent (v%) against CO 2 and N 2 , the dominant Venus atmospheric gases, including conversion to density (kg m −3 ). These unit conversions are key to unlocking the untapped potential of the data, which represents a significant challenge given the scant calibration data in the literature. Herein, we show that our data treatments and conversions yield mixing ratios and volume percent values for H 2 O, N 2 , and SO 2 that are within error to those reported for the gas chromatograph (LGC) on the Pioneer Venus Large Probe (PVLP). For the noble gases, we developed strategies to correct for instrument biases by treating the data as a relative scale and using PVLP and Venera-based measurements as calibration points. Together, these methods, conversions, calibrations, and comparisons afford novel unit conversions for the LNMS data and yield unified measures for Venus’ atmosphere from the LNMS and LGC on the PVLP. - Conversion into mixing ratio (ppm), volume percent (v%), and density (kg m −3 ). - Mixing ratios are expressed against CO 2 and N 2 . - LNMS and LGC measurements on the PVLP are consistent.

Venus↗

Stepwise Regression Analysis of MDOE Balance Calibration Data Acquired at DNW

This paper reports a comparison of two experiment design methods applied in the calibration of a strain-gage balance. One features a 734-point test matrix in which loads are varied systematically according to a method commonly applied in aerospace research and known in the literature of experiment design as One Factor At a Time (OFAT) testing. Two variations of an alternative experiment design were also executed on the same balance, each with different features of an MDOE experiment design. The Modern Design of Experiments (MDOE) is an integrated process of experiment design, execution, and analysis applied at NASA's Langley Research Center to achieve significant reductions in cycle time, direct operating cost, and experimental uncertainty in aerospace research generally and in balance calibration experiments specifically. Personnel in the Instrumentation and Controls Department of the German Dutch Wind Tunnels (DNW) have applied MDOE methods to evaluate them in the calibration of a balance using an automated calibration machine. The data have been sent to Langley Research Center for analysis and comparison. This paper reports key findings from this analysis. The chief result is that a 100-point calibration exploiting MDOE principles delivered quality comparable to a 700+ point OFAT calibration with significantly reduced cycle time and attendant savings in direct and indirect costs. While the DNW test matrices implemented key MDOE principles and produced excellent results, additional MDOE concepts implemented in balance calibrations at Langley Research Center are also identified and described.

DeLoach, RIchard↗

SUPPLEMENT: “THE RATE OF BINARY BLACK HOLE MERGERS INFERRED FROM ADVANCED LIGO OBSERVATIONS SURROUNDING GW150914” (2016, ApJL, 833, L1)

This article provides supplemental information for a Letter reporting the rate of (BBH) coalescences inferred from 16 days of coincident Advanced LIGO observations surrounding the transient (GW) signal GW150914. In that work we reported various rate estimates whose 90% confidence intervals fell in the range 2–600 Gpc{sup −3} yr{sup −1}. Here we give details on our method and computations, including information about our search pipelines, a derivation of our likelihood function for the analysis, a description of the astrophysical search trigger distribution expected from merging BBHs, details on our computational methods, a description of the effects and our model for calibration uncertainty, and an analytic method for estimating our detector sensitivity, which is calibrated to our measurements.

79 ASTRONOMY AND ASTROPHYSICS↗

Calibration of Traceable Solid Mock 131 I Phantoms Used in an International SPECT Image Quantification Comparison

The International Atomic Energy Agency (IAEA) has organized an international comparison to assess Single Photon Emission Computed Tomography (SPECT) image quantification capabilities in 12 countries. Iodine-131 was chosen as the radionuclide for the comparison because of its wide use around the world, but for logistical reasons solid 133 Ba sources were used as a long-lived surrogate for 131 I. For this study, we designed a set of solid cylindrical sources so that each site could have a set of phantoms (having nominal volumes of 2 mL, 4 mL, 6 mL, and 23 mL) with traceable activity calibrations so that the results could be properly compared. We also developed a technique using two different detection methods for individually calibrating the sources for 133 Ba activity based on a National standard. This methodology allows for the activity calibration of each 133 Ba source with a standard uncertainty on the activity of 1.4 % for the high-level 2-, 4-, and 6-mL sources and 1.7 % for the lower-level 23 mL cylinders. This level of uncertainty allows for these sources to be used for the intended comparison exercise, as well as in other SPECT image quantification studies.

47 OTHER INSTRUMENTATION↗

Calibration and Uncertainty Estimation Using the Ensemble Kalman Filter with a Large Subsurface Flow and Transport Model - 20321

At routinely monitored groundwater contamination sites, periodically measured environmental conditions such as groundwater levels and contaminant concentrations are used to inform and confirm a conceptual site model (CSM) and guide the development and calibration of a numerical groundwater flow and transport model. The calibration of groundwater flow and transport models after each measurement (sampling) event can illuminate deficiencies in a CSM, identify areas where additional monitoring is warranted, and predict the behavior of the system to guide decision making. However, manual and automated (e.g. PEST) model calibration tools can be time-consuming and computationally expensive to implement after each sampling event. Perhaps as a result, such calibration tools generally utilize all available monitoring data simultaneously rather than sequentially assimilating monitoring data one sampling event at a time as the results from sampling become available. A more real-time data assimilation approach may reduce parameter uncertainty, quantify the value of additional monitoring data, and produce a usable model more quickly and with less effort. To mitigate the potential time-consuming aspects of manual and widely applied automated calibration techniques, a data assimilation algorithm called the ensemble Kalman filter (EnKF) was evaluated as a relatively efficient method of model calibration and uncertainty assessment via the sequential integration of monitoring data into a model. The EnKF was able to successfully and efficiently assimilate monitoring and modeling data to calibrate a complex flow and transport model at a real-world site with significant subsurface heterogeneity, uncertainty, and 12 years of monitoring data (over 4,000 individual measurements of groundwater levels and over 2,500 measurements of contaminant concentrations). Starting with an uncalibrated model data from annual sampling events were sequentially assimilated, and the resultant predication errors and estimated parameter uncertainties were tracked. After all monitoring data were assimilated, both flow and transport residuals at the end of the EnKF process were comparable to those produced via a concurrent PEST calibration effort but required fewer model simulations. Both uncertainty and prediction errors decreased over time. In a real-time application, the adequacy of the model could be assessed after each sampling event. The benefits of such a real-time approach to utilizing monitoring data include reduced costs (in the form of model updates or site characterization efforts), early flagging of possible errors in the CSM, and a reduced risk of overfitting and corresponding increased confidence in model predictions. This tool may be particularly useful compared to other calibration techniques (e.g. manual, PEST) when model runtimes are long, calibration parameters are many, or parameter uncertainty is large. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Determining HPGe Total Detection Efficiency Using γ–γ Coincidence

Abstract Both the peak and total detection efficiencies are generally needed in order to calculate sample activity from a gamma spectroscopic measurement, except in the case of isotope specific calibration. This is particularly true when the sample is in close proximity to the detector and corrections for cascade summing effects are required to avoid significant inaccuracy in the result. These corrections use the total detection efficiency to correct for summing-in and summing-out events, and the extent of the correction depends on both the geometry and the gamma cascade for the isotope in question. Experimentally determining the total efficiency is a labor intensive endeavor requiring multiple measurements with a set of single-gamma-emitting standards. Modeling the total efficiency vs. energy may be less time consuming, but is also likely to produce less confidence in the final result. Pacific Northwest National Laboratory's Radiation Detection and Nuclear Sciences group has constructed a low background 14-crystal HPGe array for sample measurement; in all measurements, samples will be in close proximity to the germanium crystals. This close geometry and the sheer number efficiency calibrations required for the system have led us to investigate methods to simplify the efficiency calibration procedure. One method we are developing uses the Y-Y coincidence plane to isolate Compton scattering event populations, allowing experimental determination of total detection efficiency values from the measurement of a single mixed isotope standard. A description of the analysis and experimental results of this method are presented.

low background HPGe High Purity Germanium detector↗

The dependence of the gradients of oxygen and nitrogen-to-oxygen on stellar age in MaNGA galaxies

For this work, we derived the oxygen abundance (O/H), the nitrogen-to-oxygen (N/O) abundance ratio, and their corresponding radial gradients for a sample of 1431 galaxies from the MaNGA DR15 survey using two different realisations of the strong line method: empirical R calibration and the Bayesian model-based HII-CHI-MISTRY (HCM) code. We find that both abundance calculation methods reveal a correlation between the O/H gradient and the stellar mass of a galaxy. This relation is non-linear, with the steepest average gradients in the intermediate mass range and flatter average gradients for high- and low-mass galaxies. The relation between the N/O gradient and the stellar mass is, on average, non-linear with the steepest gradients in the intermediate mass range (log(M/M ⊙ )~10), flatter gradients for high-mass galaxies, and the flattest gradients for low-mass galaxies. However, the general trend of steepening N/O gradients for higher masses, as reported in previous studies, remains evident. We find a dependence between the O/H and N/O gradients and the galaxy mean stellar age traced by the D(4000) index. For galaxies of lower masses, both gradients are, generally, steeper for intermediate values of D(4000) and flatter for low and high values of D(4000). Only the most massive galaxies do not show this correlation. We interpret this behaviour as an evolution of the metallicity gradients with the age of stellar population. Though the galaxies with a positive slope of the D(4000) radial gradient tend to have flatter O/H and N/O gradients, as compared to those with a negative D(4000) gradient.

79 ASTRONOMY AND ASTROPHYSICS↗

A flux-density scale for microwave frequencies.

Accurate flux-density measurements of the thermal radio source DR 21 have been made at centimeter wavelengths relative to the KPW absolute flux-density scale based on Cas A and at millimeter wavelengths relative to absolute brightness-temperature measurements of Jupiter and Saturn. The form of the absolute spectrum of DR 21 thus defined is given and used to relate two formerly independent flux-density scales. With an accuracy of about 3 percent, this spectrum of DR 21 defines a flux-density scale that can be used to calibrate antennas having beamwidths between 1 and 6 minutes of arc at microwave frequencies above 7 GHz where other methods of absolute calibration are much less accurate.

Dent, W. A.↗

AMSU-A Tropical Cyclone Maximum Sustained Winds and Web Site

The Advanced Microwave Sounding Unit (AMSU)-A instruments on the NOAA-15 and NOAA-16 satellites provide information on the warm cores of tropical cyclones from oxygen channel brightness temperature (Tb) measurements near 55 GHz. With appropriate assumptions, cyclone-scale Tb gradients can be directly related to middle-to-lower tropospheric height gradients. We have developed a method for diagnosis of maximum sustained winds (Vmax) from radially averaged Tb gradients in several of the AMSU channels. Calibration of the method with recon-based (or other in situ) winds results in better agreement than with Dvorak wind estimates. Gradient wind theory shows that the warm core Tb gradient signal increases non-linearly with wind speed, making microwave temperature sounders useful for diagnosing high wind speeds, but at the expense of a minimum useful detection limit of about 40 knots. It is found that accurate wind diagnoses depend upon (1) accounting for hydrometeor effects in the AMSU channels, and (2) maximizing signal-to-noise, since the 50 km resolution data cannot fully resolve the temperature gradients in the Vmax region, typically 10-20 km in scale. AMSU imagery and max diagnoses from specific hurricanes will be shown, including independent tests from the 2000 hurricane season.

Spencer, Roy↗

S-Preconditioner for Multi-fold Data Reduction with Guaranteed User-Controlled Accuracy

The growing gap between the massive amounts of data generated by petascale scientific simulation codes and the capability of system hardware and software to effectively analyze this data necessitates data reduction. Yet, the increasing data complexity challenges most, if not all, of the existing data compression methods. In fact, lossless compression techniques offer no more than 10% reduction on scientific data that we have experience with, which is widely regarded as effectively incompressible. To bridge this gap, in this paper, we advocate a transformative strategy that enables fast, accurate, and multi-fold reduction of double-precision floating-point scientific data. The intuition behind our method is inspired by an effective use of preconditioners for linear algebra solvers optimized for a particular class of computational dwarfs (e.g., dense or sparse matrices). Focusing on a commonly used multi-resolution wavelet compression technique as the underlying solver for data reduction we propose the S-preconditioner, which transforms scientific data into a form with high global regularity to ensure a significant decrease in the number of wavelet coefficients stored for a segment of data. Combined with the subsequent EQ-calibrator, our resultant method (called S-Preconditioned EQ-Calibrated Wavelets (SPEQC-WAVELETS)), robustly achieved a 4- to 5- fold data reduction while guaranteeing user-defined accuracy of reconstructed data to be within 1% point-by-point relative error, lower than 0:01 Normalized RMSE, and higher than 0:99 Pearson Correlation. In this paper, we show the results we obtained by testing our method on six petascale simulation codes including fusion, combustion, climate, astrophysics, and subsurface groundwater in addition to 13 publicly available scientific datasets. We also demonstrate that application-driven data mining tasks performed on decompressed variables or their derived quantities produce results of comparable quality with the ones for the original data.

Jin, Ye↗

Performance of a dynamic single bubbler in single and two-phase immiscible liquids

Ensuring nonproliferation and safeguards of special nuclear materials (SNM) is a critical aspect of advancing the nuclear fuel cycle. Traditional bubbler systems used to estimate liquid levels and densities in nuclear recycling processes have limitations, particularly in harsh environments where dip-tube corrosion and buildup necessitate frequent maintenance and recalibration. This study explores the Dynamic Single Bubbler (DSB) method, which utilizes a single dip-tube attached to a linear actuator to estimate liquid properties dynamically. This approach is extended to estimate liquid-liquid interfaces in immiscible liquids and employs a linear regression method to reduce uncertainties and improve accuracy. The DSB method achieved density estimate uncertainties of less than 0.5% and surface level estimate uncertainties typically under 0.5%, across various fluids including water, acetone, methanol, mineral oil, glycerol, and aqueous salt solutions. Results indicate that the DSB method provides accurate and robust estimates of liquid density and surface levels with minimal maintenance and without the need for calibration. Additionally, the method's applicability to immiscible liquids and various dip-tube geometries was demonstrated, showing promise for widespread use in nuclear and other industrial applications.

98 - NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL↗

Inversion for Eigenvalues and Modes Using Sierra-SD and ROL.

In this report we formulate eigenvalue-based methods for model calibration using a PDE-constrained optimization framework. We derive the abstract optimization operators from first principles and implement these methods using Sierra-SD and the Rapid Optimization Library (ROL). To demon- strate this approach, we use experimental measurements and an inverse solution to compute the joint and elastic foam properties of a low-fidelity unit (LFU) model.

42 ENGINEERING↗

Top Quark Mass Measurement in the Lepton + Jets Channel Using a Matrix Element Method and \textit{in situ} Jet Energy Calibration

A precision measurement of the top quark mass m{sub t} is obtained using a sample of t{bar t} events from p{bar p} collisions at the Fermilab Tevatron with the CDF II detector. Selected events require an electron or muon, large missing transverse energy, and exactly four high-energy jets, at least one of which is tagged as coming from a b quark. A likelihood is calculated using a matrix element method with quasi-Monte Carlo integration taking into account finite detector resolution and jet mass effects. The event likelihood is a function of m{sub t} and a parameter {Delta}{sub JES} used to calibrate the jet energy scale in situ. Using a total of 1087 events, a value of m{sub t} = 173.0 {+-} 1.2 GeV/c{sup 2} is measured.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Model Calibration with Censored Data

Here, the purpose of model calibration is to make the model predictions closer to reality. The classical Kennedy-O'Hagan approach is widely used for model calibration, which can account for the inadequacy of the computer model while simultaneously estimating the unknown calibration parameters. In many applications, the phenomenon of censoring occurs when the exact outcome of the physical experiment is not observed, but is only known to fall within a certain region. In such cases, the Kennedy-O'Hagan approach cannot be used directly, and we propose a method to incorporate the censoring information when performing model calibration. The method is applied to study the compression phenomenon of liquid inside a bottle. The results show significant improvement over the traditional calibration methods, especially when the number of censored observations is large.

97 MATHEMATICS AND COMPUTING↗