Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “building case study”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,351 records · Page 75

Some aspects of space propulsion with extraterrestrial resources

Extraterrestrial resources for space processing of chemicals, in general, and propellants, in particular, are explored quantitatively. It is seen that, for several candidate space mission scenarios, space processing of both space resources and earth-carried resources can make decisive differences in the mission success for a given payload. To fix ideas and demonstrate trends, the specific case of water splitting to extract oxygen, discard (or use without storage) the resulting hydrogen, and burn earth-carried noncryogenic liquid fuel(s) in a simple rocket motor, designed for periodic thrusting, is treated in some detail. Experimental hardware is assembled and demonstrated to perform adequately, besides showing compactness of the space-packaged 'capsule' module that is self-contained. Building upon previous studies, the concept of in situ propellant production (ISPP) is reexamined in light of more recent energy and materials technologies. Missions to comets and Mars Sample Return are mentioned as candidate scenarios. The mission duration, reliability-repairability of hardware, resource availability in low earth orbit (LEO), and the thrust requirements are considered in turn. It is seen that space storage of hydrogen for extended durations (5-10 years) involves problems that require detailed studies, besides involving many presently unanswered issues. A study of the energy option in LEO and in deep space is developed in simple terms. The different solar, radioisotope, and nuclear power sources are mentioned. Storage and handling of raw and processed chemicals are considered.

Ramohalli, Kumar↗

Existing Whole-House Solutions Case Study: Exterior Insulation Pre- and Post-Retrofit, Syracuse, New York

In this study, IBACOS, in collaboration with GreenHomes America, Inc., was contracted by the New York State Energy Research and Development Authority (NYSERDA) to research exterior wall insulation solutions for enclosure upgrades. This case study describes the deep energy retrofit of three test homes in the Syracuse, New York area and represent these enclosure strategies: rigid foam insulation; spray foam insulation, and a control house that follows Home Performance with ENERGY STAR (HPwES) guidelines.

DEEP ENERGY RETROFITS↗

Bayesian discovery of optimal reduced order models from mechanistic and experimental data: A case study of Pd penetration in TRISO fuels using BISON

TRistructural ISOtropic (TRISO) particles rely on a silicon carbide (SiC) layer as the primary structural material and barrier to metallic fission products (FPs) release. Accurate prediction of palladium (Pd) transport and penetration is therefore critical for qualifying TRISO fuels for advanced reactors. The empirical correlation for Pd penetration in BISON is derived from historical particle-fuel data, but cannot explain the large scatter in the experimental data that arises from varying experimental conditions. To aid fuel qualification, we previously developed a mechanistic reduced order model (ROM) using BISON that resolves these dependencies. Here, in this work we build on that mechanistic ROM and perform validation and quantify its uncertainty using Bayesian uncertainty quantification (UQ). calibration against a suite of in-pile and out-of-pile experiments spanning particle compositions, geometries, and operating conditions, and we benchmark it against the empirical correlation. Bayesian UQ identifies influential parameters, calibrates them to data, and yields predictive intervals. Results show that while the empirical correlation can be tuned to fit a single experiment type, it transfers poorly; the mechanistic ROM sustains accuracy with credible uncertainty across disparate conditions. This demonstrates a practical path—via Bayesian UQ applied to mechanistic ROMs—to leverage single-effect experiments for inferring in-reactor behavior and supporting TRISO fuel qualification.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

New Whole-House Solutions Case Study: Challenges of Achieving 2012 IECC Air Sealing Requirements in Multifamily Dwellings, Upstate New York

While previous versions of the International Energy Conservation Code (IECC) have included provisions to improve the air tightness of dwellings, for the first time, the 2012 IECC mandates compliance verification through blower door testing. Simply completing the Air Barrier and Insulation Installation checklist through visual inspection is no longer sufficient; the 2012 IECC mandates a significantly stricter air sealing requirement. In Climate Zones 3 through 8, air leakage may not exceed 3 ACH50, which is a significant reduction from the 2009 IECC requirement of 7 ACH50. This requirement is for all residential buildings, which includes low-rise multifamily dwellings. While this air leakage rate requirement is an important component to achieving an efficient building thermal envelope, currently, the code language doesn't explicitly address differences between single family and multifamily applications. In addition, the 2012 IECC does not provide an option to sample dwellings for larger multifamily buildings, so compliance would have to be verified on every unit. With compliance with the 2012 IECC air leakage requirements on the horizon, several of Building America team Consortium for Advanced Residential Building's (CARB) multifamily builder partners are evaluating how best to comply with this requirement. Builders are not sure whether it is more practical or beneficial to simply pay for guarded testing or to revise their air sealing strategies to improve compartmentalization to comply with code requirements based on unguarded blower door testing. This report summarizes CARB's research that was conducted to assess the feasibility of meeting the 2012 IECC air leakage requirements in three multifamily buildings.

air leakage↗

An agent-based hardware-in-the-loop simulation framework for building controls

In general, a hardware-in-the-loop (HIL) building simulation has lower cost and fewer practical limitations (e.g., scheduling issues) than field tests in occupied buildings, while also overcoming limitations of simulations alone by capturing the full behavior of some physical systems, equipment, and components. However, the implementation of an HIL can be difficult due to the scarcity of appropriate tools. Here, this paper presents an agent-based framework for HIL simulation. It can be used for investigation of controller performance via controller-in-the-loop simulations and also HIL for system synthesis. In the latter case, both controllers and major equipment participate in tests to ensure that dynamics of equipment operation are correctly captured in addition to controller performance. The HIL simulation framework presented allows such actual physical parts to be included in the framework while representing others for which behaviors are better known and modeled in simulation models. The mechanism implemented in the framework to synchronize simulations in software with real-time operation of physical equipment is described. Lastly, as an example, use of the HIL simulation framework is illustrated through a brief study of speed control of the supply fan in the air handling unit of a variable-air-volume building heating, ventilating and air-conditioning system.

42 ENGINEERING↗

Evaluation of Automated Model Calibration Techniques for Residential Building Energy Simulation

This simulation study adapts and applies the general framework described in BESTEST-EX (Judkoff et al 2010) for self-testing residential building energy model calibration methods. BEopt/DOE-2.2 is used to evaluate four mathematical calibration methods in the context of monthly, daily, and hourly synthetic utility data for a 1960's-era existing home in a cooling-dominated climate. The home's model inputs are assigned probability distributions representing uncertainty ranges, random selections are made from the uncertainty ranges to define "explicit" input values, and synthetic utility billing data are generated using the explicit input values. The four calibration methods evaluated in this study are: an ASHRAE 1051-RP-based approach (Reddy and Maor 2006), a simplified simulated annealing optimization approach, a regression metamodeling optimization approach, and a simple output ratio calibration approach. The calibration methods are evaluated for monthly, daily, and hourly cases; various retrofit measures are applied to the calibrated models and the methods are evaluated based on the accuracy of predicted savings, computational cost, repeatability, automation, and ease of implementation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Development and Analysis of the Automated Object Reentry Survival Analysis Tool Parametric Study Wrapper

The NASA Orbital Debris Program Office (ODPO) Safety Group at the Johnson Space Center analyzes reentering spacecraft at the end of life. The program primarily used by ODPO in this effort is the Object Reentry Survival Analysis Tool (ORSAT). ORSAT utilizes shape primitives as well as a variety of other parameters (material, size, thickness, aerodynamic mass, orbit inclination, etc.) to simulate the reentry process and ultimately, to determine if a spacecraft could be hazardous to the population on the ground. The NASA ODPO plans to automate the ORSAT process to run multiple ORSAT input files either concurrently or consecutively. This type of automation program will provide several benefits. First, there is a need to run large parametric studies for ORSAT analysts to gain a greater understanding of reentering object’s sensitivity to certain input variables. Secondly, a database of pre-run ORSAT cases will be used to develop a survivability model, which could be made available to spacecraft developers as a design for demise (D4D) tool. The recently completed Automated Object Reentry Survival Analysis Tool (AutoORSAT) Wrapper is currently being used to build a survivability database, the first step in developing a survivability model. Already, the data that AutoORSAT has produced provides a greater understanding of the sensitivity of variables such as the initial temperature of the spacecraft, spacecraft breakup altitude, and the aerodynamic mass of spacecraft.

Smith, Andrew N.↗

Knowledge Transfer Project: Cultivating Smart Energy Solutions through Dynamic Peer-to-Peer Learning

As energy policy makers and professionals convene in the Oresund region for the 9th Annual Clean Energy Ministerial (CEM9), the global community is as united as ever around the common goal of accelerating the transition to global clean energy. Through sustained collective effort and thought leadership, CEM partners and stakeholders are systematically addressing the barriers to the widescale deployment of clean energy technologies. Pivotal to their progress is the efficient sharing and dissemination of knowledge. To address that need, the CEM-initiative International SmartGrid Action Network (ISGAN) launched the Knowledge Transfer Project (KTP) in March 2016 to capture, collect, and share knowledge about smart grid technologies among countries and key stakeholders. Building on ISGAN's experience with delivering deep-dive workshops, the KTP fosters meaningful international dialogue on smart grids with a focus on developing competence and building capacity. After a successful 2016 pilot project and two consecutive projects, each with a different focus and structure, the KTP has become an established practice that can support existing ISGAN or CEM initiatives. To accommodate different purposes, needs, and practical circumstances, ISGAN has adopted three basic models for delivering KTP workshops: Country-Centric, Multilateral, and Hybrid. This fact sheet describes each approach through case studies of workshops in Mexico, India, and Belgium, and invites new ideas and partners for future KTPs.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

New Whole-House Solutions Case Study: Schneider Homes, Inc.

Schneider Homes cut energy use by 50% over the 2004 IECC on 28 homes built near Seattle in 2008. Schneider packed the walls with R-23 of blown fiberglass and blanketed the ceiling with R-38 of blown cellulose. Ducts went into conditioned space through open-web floor trusses between floors and air handlers went into an air sealed garage closet.

blown cellulose↗

DOE Zero Energy Ready Home Case Study: KB Homes, San Marcos, California

Designed to produce as much energy as it uses, the ZeroHouse incorporates a PV system, R-15 fiberglass batts in walls, and slab-on-grade foundation. The builder ranked fifth in the nation on Builder Magazine’s 2012 Top 100 ranking of U.S. home builders based on number of housing starts, and won a 2013 Housing Innovation Award in the production builder category.

Building America↗

Technology Solutions Case Study: Innovative Retrofit Foundation Insulation Strategies, Minneapolis, Minnesota

Basements in climates 6 & 7 can account for a fraction of a home's total heat loss when fully conditioned. These foundations are a source of moisture, with convection in open block cavities redistributing water from the wall base, usually when heating. Even when block cavities are capped, the cold foundation concrete can act as a moisture source for wood rim joist components that are in contact with the wall. As below-grade basements are increasingly retrofitted for habitable space, cold foundation walls pose increased challenges for moisture durability, energy use, and occupant comfort. To address this challenge, the NorthernSTAR Building America Partnership evaluated a retrofit insulation strategy for foundations that is designed for use with open-core concrete block foundation walls. The three main goals were to improve moisture control, improve occupant comfort, and reduce heat loss.

Building America↗

Electrification Options for Multi-Family Water Heating in Cold Climates - Final Report

In multi-family buildings, large water storage tanks in centralized domestic hot water (DHW) systems can serve as thermal energy storage (TES) batteries to mitigate grid impact. These systems offer demand shift and efficiency benefits, significantly reducing peak power consumption, particularly in cold climates. This study evaluates the load-shifting benefits of a centralized heat pump water heater (HPWH) system equipped with a CO2 heat pump in multi-family buildings through simulation. The heat pump system and water storage tank are sized using design-day sizing. A finite-element-based stratified tank model and CO2 heat pump performance map from a commercial DHW product are used. Annual simulations are conducted to assess the benefits of the centralized DHW system for energy efficiency improvements, load shifting, and emission reductions. These simulations incorporate utility tariffs and marginal grid emission data from Los Angeles and Chicago. In Los Angeles, using a water tank as a thermal battery achieves 7.4% utility cost savings and 10.2% emission reduction. In Chicago, compared to HPWH conventional operation without preheating, TES-enabled central HPWH provides 15% utility cost savings and 13% emission reduction. The case study demonstrates that the demand reduction potential of central CO2 HPWHs is significant in cold climate regions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗