Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “array”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,351 records · Page 75

High-speed X-ray imaging pixel array detector for synchrotron bunch isolation

A wide-dynamic-range imaging X-ray detector designed for recording successive frames at rates up to 10 MHz is described. X-ray imaging with frame rates of up to 6.5 MHz have been experimentally verified. The pixel design allows for up to 8–12 frames to be stored internally at high speed before readout, which occurs at a 1 kHz frame rate. An additional mode of operation allows the integration capacitors to be re-addressed repeatedly before readout which can enhance the signal-to-noise ratio of cyclical processes. This detector, along with modern storage ring sources which provide short (10–100 ps) and intense X-ray pulses at megahertz rates, opens new avenues for the study of rapid structural changes in materials. The detector consists of hybridized modules, each of which is comprised of a 500 µm-thick silicon X-ray sensor solder bump-bonded, pixel by pixel, to an application-specific integrated circuit. The format of each module is 128 × 128 pixels with a pixel pitch of 150 µm. In the prototype detector described here, the three-side buttable modules are tiled in a 3 × 2 array with a full format of 256 × 384 pixels. Lastly, we detail the characteristics, operation, testing and application of the detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Submillisecond X-ray photon correlation spectroscopy from a pixel array detector with fast dual gating and no readout dead-time

Small-angle scattering X-ray photon correlation spectroscopy (XPCS) studies were performed using a novel photon-counting pixel array detector with dual counters for each pixel. Each counter can be read out independently from the other to ensure there is no readout dead-time between the neighboring frames. A maximum frame rate of 11.8 kHz was achieved. Results on test samples show good agreement with simple diffusion. Lastly, the potential of extending the time resolution of XPCS beyond the limit set by the detector frame rate using dual counters is also discussed.

43 PARTICLE ACCELERATORS↗

Sub-microsecond-resolved multi-speckle X-ray photon correlation spectroscopy with a pixel array detector

Small-angle X-ray photon correlation spectroscopy (XPCS) measurements spanning delay times from 826 ns to 52.8 s were performed using a photon-counting pixel array detector with a dynamic range of 0–3 (2 bits). Fine resolution and a wide dynamic range of time scales was achieved by combining two modes of operation of the detector: (i) continuous mode, where data acquisition and data readout are performed in parallel with a frame acquisition time of 19.36 µs, and (ii) burst mode, where 12 frames are acquired with frame integration times of either 2.56 µs frame –1 or 826 ns frame –1 followed by 3.49 ms or 1.16 ms, respectively, for readout. The applicability of the detector for performing multi-speckle XPCS was demonstrated by measuring the Brownian dynamics of 10 nm-radius gold and 57 nm-radius silica colloids in water at room temperature. In addition, the capability of the detector to faithfully record one- and two-photon counts was examined by comparing the statistical distribution of photon counts with expected probabilities from the negative binomial distribution. In conclusion, it was found that in burst mode the ratio of 2s to 1s is markedly smaller than predicted and that this is attributable to pixel-response dead-time.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Spread Spectrum Time Domain Reflectometry for Complex Impedances: Application to PV Arrays

Spread spectrum time domain reflectometry (SSTDR) has previously been used for detection and location of intermittent faults on live electrical wiring. These intermittent faults can be open circuits, short circuits, or resistive changes, all of which preserve the original shape of the SSTDR correlated waveform. But things are very different when SSTDR encounters a complex impedance discontinuity such as a capacitor or inductor. In this case, the reflection is a function of frequency, changing the shape of the SSTDR signature. In this paper, we will show the SSTDR response to single capacitors and inductors. We will also explore how SSTDR responds to arrays of PV panels (which are capacitive) connected by wires. We will show both simulations and measurements. In some configurations, it is relatively easy to see faults, although algorithms are still under development. In other configurations, little change occurs, which makes it very difficult to create a system for testing for these faults.

14 SOLAR ENERGY↗

Magnetization Reversal of Three-Dimensional Nickel Anti-Sphere Arrays

Three-dimensional antisphere arrays (3DAAs) of Ni have been fabricated here using electrochemical deposition into self-assembled polystyrene sphere templates, which offers the advantage of straightforward scalability. Using the first-order reversal curve (FORC) method, the magnetic reversal mechanism is identified from the characteristic features in the FORC distribution. A left-bending boomerang-like feature is observed in the thinnest sample, which transforms to a ridge oriented along the local coercivity H c axis with increasing sample thickness. This transformation identifies a change in the reversal process from an exchange dominated domain-growth reversal to a localized weakly interacting particle-like reversal. Micromagnetic simulations confirm the decrease in domain growth and increase of pinning behaviors as the thickness of the Ni 3DAAs structure increases, providing strong support to the FORC analysis and interpretation.

36 MATERIALS SCIENCE↗

Assessment and Performance of Flexible Quench Antenna Array Diagnostics for Superconducting Magnets

FNAL has been developing multiple versions of flexible quench antennas (flex-QA), including some specially optimized for high sensitivity and/or high resolution, to characterize quench events and transients during current ramping in superconducting magnets. A fundamental feature in our use of these is the creation of grid-like structures of sensitive elements to cover coil surfaces, with the aim of getting precise localization of magnetic flux-change events. The flex-QA are coupled with fast data-acquisition, allowing comprehensive analysis of signals at the relevant fine time scales. In addition to arrays of various flex-QA types being used during cryogenic testing of superconducting magnets, we also are utilizing a newly developed room temperature test stand to better understand QA response characteristics. The data from actual superconducting magnet tests, warm test stand measurements, and simulation data on the same QA designs allows us to draw conclusions on operational feasibility and plan better for improvements of our sensors. In this paper we present data from the multiple tests performed and analysis results. Flex-QA designs are compared, and their features, options, and optimization discussed.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Signal Whisperers: Enhancing Wireless Reception Using DRL-Guided Reflector Arrays

This paper presents a multi-agent reinforcement learning (MARL) approach for controlling adjustable metallic reflector arrays to enhance wireless signal reception in non-line-of-sight (NLOS) scenarios. Unlike conventional reconfigurable intelligent surfaces (RIS) that require complex channel estimation, our system employs a centralized training with decentralized execution (CTDE) paradigm where individual agents corresponding to reflector segments autonomously optimize reflector element orientation in three-dimensional space using spatial intelligence based on user location information. Through extensive ray-tracing simulations with dynamic user mobility, the proposed multi-agent beam-focusing framework demonstrates substantial performance improvements over single-agent reinforcement learning baselines, while maintaining rapid adaptation to user movement within one simulation step. Comprehensive evaluation across varying user densities and reflector configurations validates system scalability and robustness. The results demonstrate the potential of learning-based approaches for adaptive wireless propagation control.

deep reinforcement learning↗

Mid-Atomic-Number Cylindrical Wire Array Precursor Plasma Studies on Zebra

The precursor plasmas from low wire number cylindrical wire arrays (CWAs) were previously shown to radiate at temperatures >300 eV for Ni-60 (94% Cu and 6% Ni) wires in experiments on the 1-MA Zebra generator. Continued research into precursor plasmas has studied additional midatomic-number materials including Cu and Alumel (95% Ni, 2% Al, 2% Mn, and 1% Si) to determine if the >300 eV temperatures are common for midatomic-number materials. Additionally, current scaling effects were observed by performing CWA precursor experiments at an increased current of 1.5 MA using a load current multiplier. Our results show an increase in a linear radiation yield of ~50% (16 versus 10 kJ/cm) for the experiments at increased current. However, plasma conditions inferred through the modeling of X-ray time-gated spectra are very similar for the precursor plasma in both current conditions.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Binary pseudo-random array standard for extreme ultraviolet lithography tool characterization

Extreme ultraviolet (EUV) imaging tools play a crucial role in EUV lithography. Achieving high accuracy in EUV metrology is essential for advanced semiconductor manufacturing. A thorough characterization of the instrumentation in use is required. Binary pseudo-random arrays (BPRAs) are an established standard for calibrating and characterizing optical instruments in the frequency domain. Here, we expand the BPRA standard to applications in EUV imaging. To extend the technology to the EUV spectral range, a high-resolution BPRA target with the smallest feature size of 40 nm is developed. The EUV BPRA target establishes an in situ and portable calibration and alignment standard for EUV imaging. The target is patterned by means of electron-beam lithography, using a nickel absorber with a thickness of 39 nm. The substrate is a 4″ silicon wafer with a molybdenum/silicon multilayer coating. To demonstrate the efficacy of the target and develop the instrument calibration protocol, the target is imaged on the Sharp Hyper-NA Actinic Reticle Review Project EUV mask microscope. Power spectral density (PSD) data are presented. The characteristics of the imaging system are imprinted on the PSD. The modulation transfer function is extracted from the PSD data. A partially coherent imaging model is used as a reference to the experimental results.

BPRA↗

Detection of Epstein-Barr virus (EBV) in human lymphoma tissue by a novel microbial detection array

Background: Infectious agents are estimated to play a causative role in approximately 20% of cancers worldwide. Viruses, notably the Epstein-Barr virus (EBV), are associated with 10-15% of B-cell lymphomas and are found at a higher frequency in immunosuppressed patients. In this study, we screened human lymphoma tissues using a novel Lawrence Livermore Microbial Detection Array (LLMDA), a comprehensive detection system that contains probes for all sequenced viruses and bacteria. This technology has been applied to identify pathogen-associated diseases. Results: We evaluated samples from 58 cases with various lymphoid tissue disorders using LLMDA. These included 30 B-cell lymphomas (9 indolent and 21 aggressive type), 2 T-cell lymphomas and 2 NK/T cell lymphomas, 4 plasmacytomas as well as 8 specimens of benign lymphoid tissue. Five of 21 high-grade B-cell lymphomas were positive for Epstein-Barr virus-encoded small RNA (EBER+), while all the indolent B-cell lymphomas were EBER-. Similarly, both NK/T cell lymphomas were EBER+, and the benign tissues were EBER-. We also screened 10 cases of post-transplant lymphoproliferative disorder (PTLD). Five of these cases (4 B-cell lymphomas and 1 NK/T cell lymphoma) were EBER+, and the remaining five cases were EBER-. Conclusions: We have confirmed the reliability of the LLMDA methods by detecting EBV in EBV-positive lymphomas while observing no false-positive results in EBV-negative lymphomas. The LLMDA technique provides a sensitive and alternative method for identifying known viral pathogen associated with tumors and may prove useful for future clinical identification of novel cancer-associated viral pathogens.

59 BASIC BIOLOGICAL SCIENCES↗

Time resolved photo-luminescent decay characterization of mercury cadmium telluride focal plane arrays

The minority carrier lifetime is a measurable material property that is an indication of infrared detector device performance. To study the utility of measuring the carrier lifetime, an experiment has been constructed that can time resolve the photo-luminescent decay of a detector or wafer sample housed inside a liquid nitrogen cooled Dewar. Motorized stages allow the measurement to be scanned over the sample surface, and spatial resolutions as low as 50µm have been demonstrated. A carrier recombination simulation was developed to analyze the experimental data. Results from measurements performed on 4 mercury cadmium telluride focal plane arrays show strong correlation between spatial maps of the lifetime, dark current, and relative response.

36 MATERIALS SCIENCE↗

RANS Simulation VBM of Array of Three Coaxial Lab Scaled DOE RM1 MHK Turbine with 5D Spacing

Attached are the .cas and .dat files along with the required User Defined Functions (UDFs) and look-up table of lift and drag coefficients for the Reynolds Averaged Navier-Stokes (RANS) simulation of three coaxially located lab-scaled DOE RM1 turbine implemented in ANSYS FLUENT CFD-package. The lab-scaled DOE RM1 is a re-design geometry, based of the full scale DOE RM1 design, producing same power output as the full scale model, while operating at matched Tip Speed Ratio values at reachable laboratory Reynolds number (see attached paper). In this case study the flow field around and in the wake of the lab-scaled DOE RM1 turbines in a coaxial array is simulated using Blade Element Model (a.k.a Virtual Blade Model [VBM]) by solving RANS equations coupled with k-\omega turbulence closure model. It should be highlighted that in this simulation the actual geometry of the rotor blade is not modeled. The effect of turbine rotating blades are modeled using the Blade Element Theory. This simulation provides an accurate estimate for the performance of each device and structure of their turbulent far wake. The results of these simulations were validated against the developed in-house experimental data. Simulations for other turbine configurations are available upon request.

16 TIDAL AND WAVE POWER↗

Evaluation and Development of Phase Array Ultrasonic Testing (PAUT) System for Additively Manufactured Parts

This research focuses on the application of advanced ultrasonic testing techniques developed by The Phased Array Company (TPAC) for inspecting defects in additive manufacturing (AM) parts. Traditionally, X-ray computed tomography is the standard for inspecting AM components. Although, the long inspection and analysis time, along with relatively high cost make implementation difficult. Thus, an alternative nondestructive evaluation (NDE) approach is necessary to support quality assurance efforts within the field of AM. TPAC is recognized as a leader in ultrasonic testing innovation, deploying sophisticated algorithms such as Total Focusing Method (TFM) and Phased Wave Imaging (PWI) for ultrasonic data processing and interpretation. This work will explore how the TFM and PWI algorithms can assist defect detection within polymer AM parts. The AM field is seeking novel NDE methods to provide support within quality control and assurance efforts. Advanced ultrasonics inspection have the potential to fulfill this need.

99 GENERAL AND MISCELLANEOUS↗

Evaluation and Development of Phase Array Ultrasonic Testing (PAUT) System for Additively Manufactured Parts

This research focuses on the application of advanced ultrasonic testing techniques developed by The Phased Array Company (TPAC) for inspecting defects in additive manufacturing (AM) parts. Traditionally, X-ray computed tomography is the standard for inspecting AM components. Although, the long inspection and analysis time, along with relatively high cost make implementation difficult. Thus, an alternative nondestructive evaluation (NDE) approach is necessary to support quality assurance efforts within the field of AM. TPAC is recognized as a leader in ultrasonic testing innovation, deploying sophisticated algorithms such as Total Focusing Method (TFM) and Phased Wave Imaging (PWI) for ultrasonic data processing and interpretation. This work will explore how the TFM and PWI algorithms can assist defect detection within polymer AM parts. The AM field is seeking novel NDE methods to provide support within quality control and assurance efforts. Advanced ultrasonics inspection have the potential to fulfill this need.

36 MATERIALS SCIENCE↗

Nondestructive Ultrasonic Inspection of Composite Materials: A Comparative Advantage of Phased Array Ultrasonic

Carbon- and glass fiber-reinforced polymer (CFRP and GFRP) composite materials have been used in many industries such as aerospace and automobile because of their outstanding strength-to-weight ratio and corrosion resistance. The quality of these materials is important for safe operation. Nondestructive testing (NDT) techniques are an effective way to inspect these composites. While ultrasonic NDT has previously been used for inspection of composites, conventional ultrasonic NDT, using single element transducers, has limitations such as high attenuation and low signal-to-noise ratio (SNR). Using phased array ultrasonic testing (PAUT) techniques, signals can be generated at desired distances and angles. These capabilities provide promising results for composites where the anisotropic structure makes signal evaluation challenging. Defect detection in composites based on bulk and guided waves are studied. The capability of the PAUT and its sensitivity to flaws were evaluated by comparing the signal characteristics to the conventional method. The results show that flaw sizes as small as 0.8 mm with penetration depth up to 25 mm can be detected using PAUT, and the result signals have better characteristics than the conventional ultrasonic technique. In addition, it has been shown that guided wave generated by PAUT also has outstanding capability of flaw detection in composite materials.

36 MATERIALS SCIENCE↗