Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “adaptive imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,351 records · Page 75

Lossless compression of NOAA-AVHRR satellite data

A high-performance lossless compression system for satellite NOAA data is developed. The data is called 'high resolution picture transmission' (HRPT) data, and consists of around 93 percent advanced very high resolution radiometer (AVHRR) multi-channel image data and 7 percent of miscellaneous data. In compressing the image portion, we classify each pixel into 10 different groups and apply a multi-channel prediction and a non-linear error conversion. The entropy coder is an arithmetic coder which is adaptive and regenerates the approximation of the statistical properties of the source as an initial probability table. To compress the non-image part, we used the general compressor (gzip). From experimental results, the original information is compressed down to 25 percent to approx. 40 percent.

Takamura, Seishi↗

Electronic Scanning Strategies in Adaptive Electrical Capacitance Volume Tomography: Tradeoffs and Prospects

Electrical Capacitance Volume Tomography (ECVT) has been applied for imaging of multiphase flows found in industrial applications. The ill-posed nature of the image reconstruction problem in ECVT and the consequent low resolution can be alleviated by employing electronic scanning enabled by electrode segmentation and reconfiguration during data acquisition. Here we study electronic scanning strategies that mimic physical rotation and shifting of the sensor along its symmetry axis. First, we study the feasibility of electronic scanning by analyzing the capacitance transducer circuit in SPICE. Then, we simulate electronic scanning using the finite element method for different electrode shapes, for which we compare the image reconstruction results and acquisition time. We find a noticeable improvement in image resolution for the scanning cases over conventional ECVT. Lastly, among the scanning cases, we emphasize a particular electrode shape that provides the best image resolution along with the minimal amount of acquisition time.

47 OTHER INSTRUMENTATION↗

Wavefront Control and Image Restoration with Less Computing

PseudoDiversity is a method of recovering the wavefront in a sparse- or segmented- aperture optical system typified by an interferometer or a telescope equipped with an adaptive primary mirror consisting of controllably slightly moveable segments. (PseudoDiversity should not be confused with a radio-antenna-arraying method called pseudodiversity.) As in the cases of other wavefront- recovery methods, the streams of wavefront data generated by means of PseudoDiversity are used as feedback signals for controlling electromechanical actuators of the various segments so as to correct wavefront errors and thereby, for example, obtain a clearer, steadier image of a distant object in the presence of atmospheric turbulence. There are numerous potential applications in astronomy, remote sensing from aircraft and spacecraft, targeting missiles, sighting military targets, and medical imaging (including microscopy) through such intervening media as cells or water. In comparison with prior wavefront-recovery methods used in adaptive optics, PseudoDiversity involves considerably simpler equipment and procedures and less computation. For PseudoDiversity, there is no need to install separate metrological equipment or to use any optomechanical components beyond those that are already parts of the optical system to which the method is applied. In Pseudo- Diversity, the actuators of a subset of the segments or subapertures are driven to make the segments dither in the piston, tilt, and tip degrees of freedom. Each aperture is dithered at a unique frequency at an amplitude of a half wavelength of light. During the dithering, images on the focal plane are detected and digitized at a rate of at least four samples per dither period. In the processing of the image samples, the use of different dither frequencies makes it possible to determine the separate effects of the various dithered segments or apertures. The digitized image-detector outputs are processed in the spatial-frequency (Fourier-transform) domain to obtain measures of the piston, tip, and tilt errors over each segment or subaperture. Once these measures are known, they are fed back to the actuators to correct the errors. In addition, measures of errors that remain after correction by use of the actuators are further utilized in an algorithm in which the image is phase-corrected in the spatial-frequency domain and then transformed back to the spatial domain at each time step and summed with the images from all previous time steps to obtain a final image having a greater signal-to-noise ratio (and, hence, a visual quality) higher than would otherwise be attainable.

Lyon, Richard G.↗

Cape Hatteras Ecological Conservation: Delineating Shoreline and Mapping Change Along the Cape Hatteras National Seashore for Coastline Management and Transportation Corridor Adaptation Strategies

The National Park Service at Cape Hatteras National Seashore works to protect North Carolina’s Outer Banks where frequent storms bring heavy winds and flooding, leading to overwash events on the main highway, North Carolina Highway 12. Shorelines are susceptible to erosion directly affecting transportation and housing infrastructures. Storm events can disrupt transportation on NC-12 and ferry service from Ocracoke Island to Hatteras Island, leaving inhabitants stranded on Ocracoke Island for indefinite amounts of time. The National Park Service’s current decision-making practices involve mitigating infrastructure damage by enlisting the help of North Carolina’s Department of Transportation and finding ways to relocate this infrastructure, as well as dredging and sediment placement that support beach nourishment efforts. Our NASA DEVELOP team partnered with the National Park Service to explore the use of optical data to delineate shoreline and map coastline change from 2014 to 2024. We used Earth observations collected by Landsat 8 Operational Land Imager, Landsat 9 Operational Land Imager-2, and Sentinel-2 MultiSpectral instrument to support decision-making related to prioritizing strategic planning for transportation corridor adaptations including potential relocation of infrastructure, and beach nourishment efforts. We derived coastline maps by consolidating images from each year to create composite images for winter and summer coastline seasonal oscillation patterns. The results highlight shoreline loss over the ~10-year study period, and the difference in shoreline inundation in the winter and summer seasons. These observations create a better understanding of successful mitigation efforts and allow the National Park Service to continue to focus on plans for infrastructure updates.

Ella Haugen↗

Quantification of Esophageal Tumor Motion on Cine-Magnetic Resonance Imaging

Purpose: To quantify the movement of esophageal tumors noninvasively on cine-magnetic resonance imaging (MRI) by use of a semiautomatic method to visualize tumor movement directly throughout multiple breathing cycles. Methods and Materials: Thirty-six patients with esophageal tumors underwent MRI. Tumors were located in the upper (8), middle (7), and lower (21) esophagus. Cine-MR images were collected in the coronal and sagittal plane during 60 seconds at a rate of 2 Hz. An adaptive correlation filter was used to automatically track a previously marked reference point. Tumor movement was measured in the craniocaudal (CC), left–right (LR), and anteroposterior (AP) directions and its relationship along the longitudinal axis of the esophagus was investigated. Results: Tumor registration within the individual images was typically done at a millisecond time scale. The mean (SD) peak-to-peak displacements in the CC, AP, and LR directions were 13.3 (5.2) mm, 4.9 (2.5) mm, and 2.7 (1.2) mm, respectively. The bandwidth to cover 95% of excursions from the mean position (c95) was also calculated to exclude outliers caused by sporadic movements. The mean (SD) c95 values were 10.1 (3.8) mm, 3.7 (1.9) mm, and 2.0 (0.9) mm in the CC, AP, and LR dimensions. The end-exhale phase provided a stable position in the respiratory cycle, compared with more variety in the end-inhale phase. Furthermore, lower tumors showed more movement than did higher tumors in the CC and AP directions. Conclusions: Intrafraction tumor movement was highly variable between patients. Tumor position proved the most stable during the respiratory cycle in the end-exhale phase. A better understanding of tumor motion makes it possible to individualize radiation delivery strategies accordingly. Cine-MRI is a successful noninvasive modality to analyze motion for this purpose in the future.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Characterization of Target Volume Changes During Breast Radiotherapy Using Implanted Fiducial Markers and Portal Imaging

Purpose: To determine target volume changes by using volume and shape analysis for patients receiving radiotherapy after breast conservation surgery and to compare different methods of automatically identifying changes in target volume, position, size, and shape during radiotherapy for use in adaptive radiotherapy. Methods and Materials: Eleven patients undergoing whole breast radiotherapy had fiducial markers sutured into the excision cavity at the time of surgery. Patients underwent imaging using computed tomography (for planning and at the end of treatment) and during treatment by using portal imaging. A marker volume (MV) was defined by using the measured marker positions. Changes in both individual marker positions and MVs were identified manually and using six automated similarity indices. Comparison of the two types of analysis (manual and automated) was undertaken to establish whether similarity indices can be used to automatically detect changes in target volumes. Results: Manual analysis showed that 3 patients had significant MV reduction. This analysis also showed significant changes between planning computed tomography and the start of treatment for 9 patients, including single and multiple marker movement, deformation (shape change), and rotation. Four of the six similarity indices were shown to be sensitive to the observed changes. Conclusions: Significant changes in size, shape, and position occur to the fiducial marker-defined volume. Four similarity indices can be used to identify these changes, and a protocol for their use in adaptive radiotherapy is suggested.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-F-J-173: Online Replanning for Dose Painting Based On Changing ADC Map of Pancreas Cancer

Purpose: The introduction of MR-guided radiation therapy (RT), e.g., MR-Linac, would allow dose painting to adapt spatial RT response revealed from MRI data during the RT delivery. The purpose of this study is to investigate the use of an online replanning method to adapt dose painting from the MRI Apparent Diffusion Coefficient (ADC) map acquired during the delivery of RT for pancreatic cancers. Methods: Original dose painting plans were created based on multi-parametric simulation MRI including T1, T2 and ADC, using a treatment planning system (MONACO, Elekta) equipped with an online replanning algorithm (WSO, warm start optimization). Multiple GTVs, identified based on various ADC levels were prescribed to different doses ranging from 50–70 Gy with simultaneous integrated boost in 28 fractions. The MRI acquired after RT were used to mimic weekly MRI, on which the changing GTVs, pancreatic head and other organs-at-risk (OAR) (duodenum, stomach, small bowel) were delineated. The adaptive plan was generated by applying WSO algorithm starting from the deformed original plan based on the weekly MRI using a deformable image registration (DIR) software (ADMIRE, Elekta). The online replanning method takes <10 min. including DIR, target delineation, WSO execution and final dose calculation. Standard IGRT repositioning and full-blown reoptimization plans were also generated to compare with the adaptive plans. Results: The online replanning method significantly improved the multiple target coverages and OAR sparing for pancreatic cancers. For example, for a case with two GTVs with prescriptions of 60 and 70 Gy in pancreatic head, V100-GTV70 (the volume covered by 100% of prescription dose for GTV with 70 Gy)/V100-GTV60/V100-CTV50/V45-duodenum were (95.1/22.2/69.5/85.7), (95.0/97.0/98.6/34.3), and (95.0/98.1/100.0/38.7) for the IGRT, adaptive and reoptimization plans, respectively. Conclusion: The introduced online adaptive replanning method can effectively account for interfractional changes including tumor spatial response during MR-guided RT delivery, allowing precise delivery of dose painting. This study was partially supported by Elekta Inc.

60 APPLIED LIFE SCIENCES↗

Wide-Field-of-View, High-Resolution, Stereoscopic Imager

A device combines video feeds from multiple cameras to provide wide-field-of-view, high-resolution, stereoscopic video to the user. The prototype under development consists of two camera assemblies, one for each eye. One of these assemblies incorporates a mounting structure with multiple cameras attached at offset angles. The video signals from the cameras are fed to a central processing platform where each frame is color processed and mapped into a single contiguous wide-field-of-view image. Because the resolution of most display devices is typically smaller than the processed map, a cropped portion of the video feed is output to the display device. The positioning of the cropped window will likely be controlled through the use of a head tracking device, allowing the user to turn his or her head side-to-side or up and down to view different portions of the captured image. There are multiple options for the display of the stereoscopic image. The use of head mounted displays is one likely implementation. However, the use of 3D projection technologies is another potential technology under consideration, The technology can be adapted in a multitude of ways. The computing platform is scalable, such that the number, resolution, and sensitivity of the cameras can be leveraged to improve image resolution and field of view. Miniaturization efforts can be pursued to shrink the package down for better mobility. Power savings studies can be performed to enable unattended, remote sensing packages. Image compression and transmission technologies can be incorporated to enable an improved telepresence experience.

Prechtl, Eric F.↗

Adaptive machine learning for time-varying systems: low dimensional latent space tuning

Machine learning (ML) tools such as encoder-decoder convolutional neural networks (CNN) can represent incredibly complex nonlinear functions which map between combinations of images and scalars. For example, CNNs can be used to map combinations of accelerator parameters and images which are 2D projections of the 6D phase space distributions of charged particle beams as they are transported between various particle accelerator locations. Despite their strengths, applying ML to time-varying systems, or systems with shifting distributions, is an open problem, especially for large systems for which collecting new data for re-training is impractical or interrupts operations. Particle accelerators are one example of large time-varying systems for which collecting detailed training data requires lengthy dedicated beam measurements which may no longer be available during regular operations. We present a novel method of adaptive ML for time-varying systems. Our approach is to map very high (N ≈ 100k) dimensional inputs (a combination of scalar parameters and images) into the low dimensional (N ≈ 2) latent space at the output of the encoder section of an encoder-decoder CNN. We then actively tune the low dimensional latent space-based representation of complex system dynamics by the addition of an adaptively tuned feedback vector directly before the decoder sections builds back up to our image-based high-dimensional phase space density representations. This method allows us to learn correlations within and to quickly tune the characteristics of incredibly large parameter space systems and to track their evolution in real time based on feedback without massive new data sets for re-training. We demonstrate that our method can accurately predict and track the phase space of charged particle beams at various locations in a particle accelerator by adaptively adjusting in real-time while the unknown input beam distribution of the accelerator is changing in shape, charge, and offset and while the RF system of the accelerator itself is also changing in an unpredictable way. For FACET-II we demonstrate that such an approach has the potential to use transverse deflecting cavity and energy spread spectrum beam measurements to accurately predict 2D projections of the 6D phase space of the electron beam at the plasma wakefield acceleration interaction point where such diagnostics are unavailable.

47 OTHER INSTRUMENTATION↗

TH-C-18A-12: Evaluation of the Impact of Body Size and Tube Output Limits in the Optimization of Fast Scanning with High-Pitch Dual Source CT

Purpose: To evaluate the impact of body size and tube power limits in the optimization of fast scanning with high-pitch dual source CT (DSCT). Methods: A previously validated MERCURY phantom, made of polyethylene, with circular cross-section of diameters 16, 23, 30 and 37cm, and connected through tapered sections, was scanned using a second generation DSCT system. The DSCT operates with two independently controlled x-ray tube generators offering up to 200 kW power reserve (100 kW per tube). The entire length of the phantom (42cm) was scanned with two protocols using: A)Standard single-source CT (SSCT) protocol with pitch of 0.8, and B) DSCT protocol with high-pitch values ranging from 1.6 to 3.2 (0.2 steps). All scans used 120 kVp with 150 quality reference mAs using automatic exposure control. Scanner radiation output (CTDIvol) and effective mAs values were extracted retrospectively from DICOM files for each slice. Image noise was recorded. All variables were assessed relative to phantom diameter. Results: With standard-pitch SSCT, the scanner radiation output (and tube-current) were progressively adapted with increasing size, from 6 mGy (120 mAs) up to 15 mGy (270 mAs) from the thinnest (16cm) to the thickest diameter (37 cm), respectively. By comparison, using high-pitch (3.2), the scanner output was bounded at about 8 mGy (140 mAs), independent of phantom diameter. Although relative to standard-pitch, the high-pitch led to lower radiation output for the same scan, the image noise was higher, particularly for larger diameters. To match the radiation output adaptation of standard-pitch, a high-pitch mode of 1.6 was needed, with the advantage of scanning twice as fast. Conclusion: To maximize the benefits of fast scanning with high-pitch DSCT, the body size and tube power limits of the system need to be considered such that a good balance between speed of acquisition and image quality are warranted. JCRG is an employee of Siemens Medical Solutions USA Inc.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-E-T-161: Evaluation of Dose Calculation Based On Cone-Beam CT

Purpose: The purpose of this study is to convert pixel values in cone-beam CT (CBCT) using histograms of pixel values in the simulation CT (sim-CT) and the CBCT images and to evaluate the accuracy of dose calculation based on the CBCT. Methods: The sim-CT and CBCT images immediately before the treatment of 10 prostate cancer patients were acquired. Because of insufficient calibration of the pixel values in the CBCT, it is difficult to be directly used for dose calculation. The pixel values in the CBCT images were converted using an in-house program. A 7 fields treatment plans (original plan) created on the sim-CT images were applied to the CBCT images and the dose distributions were re-calculated with same monitor units (MUs). These prescription doses were compared with those of original plans. Results: In the results of the pixel values conversion in the CBCT images,the mean differences of pixel values for the prostate,subcutaneous adipose, muscle and right-femur were −10.78±34.60, 11.78±41.06, 29.49±36.99 and 0.14±31.15 respectively. In the results of the calculated doses, the mean differences of prescription doses for 7 fields were 4.13±0.95%, 0.34±0.86%, −0.05±0.55%, 1.35±0.98%, 1.77±0.56%, 0.89±0.69% and 1.69±0.71% respectively and as a whole, the difference of prescription dose was 1.54±0.4%. Conclusion: The dose calculation on the CBCT images achieve an accuracy of <2% by using this pixel values conversion program. This may enable implementation of efficient adaptive radiotherapy.

60 APPLIED LIFE SCIENCES↗

WE-H-207B-00: MRgRT

In recent years, steady progress has been made towards the implementation of MRI in external beam radiation therapy for processes ranging from treatment simulation to in-room guidance. Novel procedures relying mostly on MR data are currently implemented in the clinic. This session will cover topics such as (a) commissioning and quality control of the MR in-room imagers and simulators specific to RT, (b) treatment planning requirements, constraints and challenges when dealing with various MR data, (c) quantification of organ motion with an emphasis on treatment delivery guidance, and (d) MR-driven strategies for adaptive RT workflows. The content of the session was chosen to address both educational and practical key aspects of MR guidance. Learning Objectives: Good understanding of MR testing recommended for in-room MR imaging as well as image data validation for RT chain (e.g. image transfer, filtering for consistency, spatial accuracy, manipulation for task specific); Familiarity with MR-based planning procedures: motivation, core workflow requirements, current status, challenges; Overview of the current methods for the quantification of organ motion; Discussion on approaches for adaptive treatment planning and delivery. T. Stanescu - License agreement with Modus Medical Devices to develop a phantom for the quantification of MR image system-related distortions.; T. Stanescu, N/A.

60 APPLIED LIFE SCIENCES↗

WE-H-207B-01: Commissioning and QC

In recent years, steady progress has been made towards the implementation of MRI in external beam radiation therapy for processes ranging from treatment simulation to in-room guidance. Novel procedures relying mostly on MR data are currently implemented in the clinic. This session will cover topics such as (a) commissioning and quality control of the MR in-room imagers and simulators specific to RT, (b) treatment planning requirements, constraints and challenges when dealing with various MR data, (c) quantification of organ motion with an emphasis on treatment delivery guidance, and (d) MR-driven strategies for adaptive RT workflows. The content of the session was chosen to address both educational and practical key aspects of MR guidance. Learning Objectives: Good understanding of MR testing recommended for in-room MR imaging as well as image data validation for RT chain (e.g. image transfer, filtering for consistency, spatial accuracy, manipulation for task specific); Familiarity with MR-based planning procedures: motivation, core workflow requirements, current status, challenges; Overview of the current methods for the quantification of organ motion; Discussion on approaches for adaptive treatment planning and delivery. T. Stanescu - License agreement with Modus Medical Devices to develop a phantom for the quantification of MR image system-related distortions.; T. Stanescu, N/A.

60 APPLIED LIFE SCIENCES↗

WE-H-207B-02: MR-Driven RT Planning

In recent years, steady progress has been made towards the implementation of MRI in external beam radiation therapy for processes ranging from treatment simulation to in-room guidance. Novel procedures relying mostly on MR data are currently implemented in the clinic. This session will cover topics such as (a) commissioning and quality control of the MR in-room imagers and simulators specific to RT, (b) treatment planning requirements, constraints and challenges when dealing with various MR data, (c) quantification of organ motion with an emphasis on treatment delivery guidance, and (d) MR-driven strategies for adaptive RT workflows. The content of the session was chosen to address both educational and practical key aspects of MR guidance. Learning Objectives: Good understanding of MR testing recommended for in-room MR imaging as well as image data validation for RT chain (e.g. image transfer, filtering for consistency, spatial accuracy, manipulation for task specific); Familiarity with MR-based planning procedures: motivation, core workflow requirements, current status, challenges; Overview of the current methods for the quantification of organ motion; Discussion on approaches for adaptive treatment planning and delivery. T. Stanescu - License agreement with Modus Medical Devices to develop a phantom for the quantification of MR image system-related distortions.; T. Stanescu, N/A.

60 APPLIED LIFE SCIENCES↗

WE-H-207B-03: MRI Guidance in the Radiation Therapy Clinic: Site-Specific Discussions

In recent years, steady progress has been made towards the implementation of MRI in external beam radiation therapy for processes ranging from treatment simulation to in-room guidance. Novel procedures relying mostly on MR data are currently implemented in the clinic. This session will cover topics such as (a) commissioning and quality control of the MR in-room imagers and simulators specific to RT, (b) treatment planning requirements, constraints and challenges when dealing with various MR data, (c) quantification of organ motion with an emphasis on treatment delivery guidance, and (d) MR-driven strategies for adaptive RT workflows. The content of the session was chosen to address both educational and practical key aspects of MR guidance. Learning Objectives: Good understanding of MR testing recommended for in-room MR imaging as well as image data validation for RT chain (e.g. image transfer, filtering for consistency, spatial accuracy, manipulation for task specific); Familiarity with MR-based planning procedures: motivation, core workflow requirements, current status, challenges; Overview of the current methods for the quantification of organ motion; Discussion on approaches for adaptive treatment planning and delivery. T. Stanescu - License agreement with Modus Medical Devices to develop a phantom for the quantification of MR image system-related distortions.; T. Stanescu, N/A.

60 APPLIED LIFE SCIENCES↗

Evidence That the Directly Imaged Planet HD 131399 Ab Is a Background Star

Herein we present evidence that the recently discovered, directly imaged planet HD 131399 Ab is a background star with nonzero proper motion. From new JHK1L ' photometry and spectroscopy obtained with the Gemini Planet Imager, VLT/SPHERE, and Keck/NIRC2, and a reanalysis of the discovery data obtained with VLT/SPHERE, we derive colors, spectra, and astrometry for HD 131399 Ab. The broader wavelength coverage and higher data quality allow us to reinvestigate its status. Its near-infrared spectral energy distribution excludes spectral types later than L0 and is consistent with a K or M dwarf, which are the most likely candidates for a background object in this direction at the apparent magnitude observed. If it were a physically associated object, the projected velocity of HD 131399 Ab would exceed escape velocity given the mass and distance to HD 131399 A. We show that HD 131399 Ab is also not following the expected track for a stationary background star at infinite distance. Solving for the proper motion and parallax required to explain the relative motion of HD 131399 Ab, we find a proper motion of 12.3 mas yr –1 . When compared to predicted background objects drawn from a galactic model, we find this proper motion to be high but consistent with the top 4% fastest-moving background stars. From our analysis, we conclude that HD 131399 Ab is a background K or M dwarf.

stars: individual (HD 131399)↗

A mesoscale 3D model of irradiated concrete informed via a 2.5 U-Net semantic segmentation

The concrete biological shield in light-water reactors is exposed to neutron and gamma irradiation, which deteriorates the concrete’s mechanical properties in the long term. To assess the irradiation-induced damage, predictive mechanical models are developed and used in parallel with the characterization of irradiated concrete samples. Realistic 3D simulation domains can drastically improve a model’s prediction. In this work, we utilized x-ray computed tomography (XCT) data of a concrete specimen to reconstruct its 3D microstructure. The XCT data shows low contrast between the concrete’s aggregates and cement paste, resulting in poor image segmentation when using traditional unsupervised techniques. To address this issue, we developed and trained a 2.5D U-Net model on only 24 pre-labeled XCT layers to segment 651 layers of the XCT data. The overall F1-score of the model is approximately 96%. Then, we created a 3D finite element (FE) mesh based on the stack of segmented images. The FE model contains radiation-induced expansion, damage, and creep. The constitutive equations are adapted to each phase (aggregates and cement paste). Here, we simulated the effects of neutron irradiation in the concrete specimen as well as the specimen’s mechanical response to uniaxial compression. Finally, model validation was performed using experimental data on similar concrete specimens in the literature.

2.5D U-Net↗

MO-AB-BRA-10: Cancer Therapy Outcome Prediction Based On Dempster-Shafer Theory and PET Imaging

Purpose: In cancer therapy, utilizing FDG-18 PET image-based features for accurate outcome prediction is challenging because of 1) limited discriminative information within a small number of PET image sets, and 2) fluctuant feature characteristics caused by the inferior spatial resolution and system noise of PET imaging. In this study, we proposed a new Dempster-Shafer theory (DST) based approach, evidential low-dimensional transformation with feature selection (ELT-FS), to accurately predict cancer therapy outcome with both PET imaging features and clinical characteristics. Methods: First, a specific loss function with sparse penalty was developed to learn an adaptive low-rank distance metric for representing the dissimilarity between different patients’ feature vectors. By minimizing this loss function, a linear low-dimensional transformation of input features was achieved. Also, imprecise features were excluded simultaneously by applying a l2,1-norm regularization of the learnt dissimilarity metric in the loss function. Finally, the learnt dissimilarity metric was applied in an evidential K-nearest-neighbor (EK- NN) classifier to predict treatment outcome. Results: Twenty-five patients with stage II–III non-small-cell lung cancer and thirty-six patients with esophageal squamous cell carcinomas treated with chemo-radiotherapy were collected. For the two groups of patients, 52 and 29 features, respectively, were utilized. The leave-one-out cross-validation (LOOCV) protocol was used for evaluation. Compared to three existing linear transformation methods (PCA, LDA, NCA), the proposed ELT-FS leads to higher prediction accuracy for the training and testing sets both for lung-cancer patients (100+/−0.0, 88.0+/−33.17) and for esophageal-cancer patients (97.46+/−1.64, 83.33+/−37.8). The ELT-FS also provides superior class separation in both test data sets. Conclusion: A novel DST- based approach has been proposed to predict cancer treatment outcome using PET image features and clinical characteristics. A specific loss function has been designed for robust accommodation of feature set incertitude and imprecision, facilitating adaptive learning of the dissimilarity metric for the EK-NN classifier.

60 APPLIED LIFE SCIENCES↗