Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “VENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,351 records · Page 75

Direct Air Capture Recovery of Energy for CCUS Partnership (DAC RECO 2 UP) Final Technical Report

The “Direct Air Capture Recovery of Energy for CCUS Partnership (DAC RECO 2 UP)” project employs a team approach and supports the U.S. Department of Energy Office of Fossil Energy and Carbon Management’s (DOE-FECM) goal to decrease the cost of capture through the testing of existing direct air capture (DAC) materials in integrated field units that produce a concentrated carbon dioxide (CO 2 ) stream of at least 95% purity. Solid-amine CO 2 adsorption-desorption contactor technology, proven in the laboratory, is undergoing high-fidelity design/validation. Recoverable energy is readily available from a large number of commercial locations where DAC can be deployed; therefore, advancing the fidelity of energy recovery to directly reduce the cost of DAC is a key project objective. In addition, many commercial facilities have low-concentration CO 2 vents that are uneconomical to treat alone but could provide more efficient mass and thermal transport to DAC systems with integrated energy recovery and flexible CO 2 treatment capabilities. Technology scale-up leverages past research and occurs in a commercially relevant environment at the National Carbon Capture Center. Prescreening techno-economic analysis, risk assessments, and life cycle analysis are being performed by experienced team members. Results of the project will address critical technical barriers that, when solved, will improve the capital and operating costs of DAC while validating commercial relevance of cost and product quality/need.

54 ENVIRONMENTAL SCIENCES↗

Reduction of Methane Leaks through Corrosion Mitigation Pre-treatments for Pipelines with Field Applied Coatings

Corrosion of buried, coated steel pipelines transporting natural gas is a significant source of methane emissions, from pipeline venting required for maintenance and repairs and from pipeline leaks and incidents. Corrosion of steel under field applied coatings is an important safety concern for the pipeline industry. This project investigates the application of a field applied alloy over girth welds to mitigate external corrosion of buried coated steel pipelines. Various metallic coating options were considered, which were required to meet several criteria: (1) it must resist corrosion under open-circuit or mild cathodic protection conditions, (2) it must protect the substrate steel, and (3) it must not negatively affect the adhesion of the field coating. Finite element models and lab testing were performed of alloy coating compositions to identify promising alloy types underneath disbonded coatings. Polarization curves of coating alloys were generated to provide the boundary conditions for the COMSOL model to compute potential and current distributions around coated areas. Sacrificial and corrosion-resistant metal alloy coatings were evaluated and optimized using corrosion modeling and laboratory electrochemical testing, where aluminum alloy 5356 (5% Mg) and steel alloy B9 (9% Cr) were selected. Corrosion test coupons were designed and fabricated using thermal spray aluminum 5356 and welded B9 steel overlays on API 5L grade X42 line pipe steel. The corrosion test coupons, with simulated pipe coating damage, were tested in a laboratory soil box and a field pipeline site in Texas for 3-months. Corrosion test coupons were then tested for 6-months at field pipeline sites in Texas and Tennessee to quantify corrosion rates and performance of the aluminum and steel alloys under polyethylene tape and 2-part epoxy coatings, various coating holidays, and with and without cathodic protection.

03 NATURAL GAS↗

Idaho National Laboratory Integrated Multisite SSHAC Level 3: Probabilistic Volcanic Hazards Assessment

The Idaho National Laboratory (INL) resides on the eastern Snake River Plain (ESRP), part of the Snake River Plain (SRP) with a complex origin and geologic history of volcanism. Much of the Quaternary (last 2.58 million years) volcanism within 400 km of INL is genetically associated with a major thermal anomaly referred to as the Yellowstone hotspot, which is currently located more than 180 km northeast of INL. Near INL, local volcanic sources include silicic domes near its southern border, and numerous dike-fed basaltic vents of the ESRP, some of which are near or within the INL boundaries. Quantitative probabilistic assessments of screened-in volcanic hazardous phenomena for nine different facility complexes at the INL are presented for a Senior Seismic Hazard Analysis Committee (SSHAC) Level 3 (SL3) study. The comprehensive, integrated multisite SSHAC study consists of a single regional Probabilistic Volcanic Hazards Assessment (PVHA) that pertains to all nine INL facility complexes, with site-specific information developed at each respective area of interest (AOI), referred to as the "INL facility AOI" (Figure ES-1). Hazard products are generated for specified INL facility AOIs for use by multiple stakeholders from different agencies in risk-informed decision-making regarding site selection, operations, and design of nuclear facilities at INL, consistent with U.S. Department of Energy (DOE) and U.S. Nuclear Regulatory Commission (NRC) regulatory guidance. The study also serves as the basis for future periodic safety assessments required for existing DOE facilities, such as 10-year evaluations of natural-phenomena hazards. Elements of the INL PVHA including initial characterization, screening, quantitative assessments of eruption and hazard potential, and consideration of facility needs are conducted using the three phases of the SSHAC process: evaluation, integration, and documentation. As per regulatory guidance, the SSHAC framework provided the necessary processes and procedures for the PVHA Technical Integration (TI) team, at three workshops, five formal working meetings and many TI team remote meetings, to conduct initial characterization, screen the volcanic hazards, create PVHA model inputs, exercise those models in the PVHA, consider facility-specific volcanic hazard needs, and perform final hazard calculations. The Participatory Peer Review Panel (PPRP) provided independent oversight and performed process and technical reviews of the PVHA throughout its duration. The study included an extensive New Data Collection and Analyses (NDCA) program developed by the PVHA TI team to reduce uncertainties in hazard-significant elements in the PVHA model. NDCA activities generated 20 reports providing important contributory datasets and results to the project database for characterizing the ESRP. For example, a report compiling the dimensions of ESRP shield volcanoes and lava fields was used to construct volcanic footprints (areas of impact), was compared with data from INL subsurface cores, and was used to validate the results of lava-flow inundation modeling on the contemporary terrain. Another example is the acquisition of aeromagnetic data over INL and its surrounding area, with maps of buried magmatic features (e.g., subsurface volcanoes and swarms of feeder dikes) that informed the PVHA conceptual model of volcanism. The SSHAC evaluation process was used to conduct all elements of the PVHA including initial characterization and screening. Existing data and NDCA activities provided the foundation to develop the tectonomagmatic conceptual model of volcanism for the region of geographical interest in the SRP and Yellowstone hotspot volcanic system, and for considering volcanoes in the western US. Considering Quaternary volcanic sources active during this period, the screening approach identified and evaluated magma compositions, types of eruptive and intrusive phenomena, types of hazardous phenomena, and proximity of sources to INL. The PVHA TI team evaluated 18 types of magmatic sources in terms of 20 potentially hazardous phenomena, resulting in 360 screening decisions. The screening process resulted in 140 screened-in hazardous volcanic phenomena for Quaternary volcanic sources 1) proximal to INL facility complexes in the ESRP (64 basaltic and 54 silicic), 2) regional sources associated with the Yellowstone caldera system and Blackfoot Reservoir volcanic field (7), and 3) more distal sources from thirteen Cascade volcanoes and two volcanoes at Long Valley caldera (CA).

58 GEOSCIENCES↗

Management of the Three Mile Island, Unit 2, Accident Corium and Severely Damaged Fuel Debris

The Three Mile Island, Unit Two (TMI-2) pressurized water reactor core melted down in 1979 due to an untimely combination of maintenance problems that led to a loss of feedwater, followed by a series of operational misunderstandings and errors. The melted core recovery process required development of a wide array of tools. After approximately three years of water management and other cleanup actions, the first views of the core revealed a much higher degree of damage than previously expected. Approximately 62 metric tons of the core had melted, leaving only 42 of the 177 fuel assemblies standing with a majority of rods intact. The core to be recovered was composed of loose debris and a solidified mass of formerly molten fuel. Robotic tools that had been designed for the task were of limited effectiveness due to the range of material types and phases. Over a period of several years, the central melt was broken up, primarily by use of a core-boring drill originally designed to acquire samples through the depth of the debris field. The broken pieces were loaded into specially designed debris canisters by use of long-handled pick-and-place tools and suctioned into baffled knockout canisters using an airlift vacuum system. A remotely operable underwater plasma arc torch was developed for removal of the lower core support structure to be able to retrieve the fuel pieces and secondary melt that had accumulated on the bottom reactor vessel head. Canister design played a central role in defining the initial retrieval process and later affected transportation, interim wet and its current interim dry storage. Due to concerns about the potential for radiolysis of residual water in the debris and other canister material, the canisters were fitted with hydrogen recombiner catalyst units to prevent a buildup of flammable gas and potential pressurization. To confirm the effectiveness of the recombiners during shipping, eight dewatered canisters were kept sealed for up to 205 days with periodic sampling of the headspace gas. The highest hydrogen value (9 vol%) was observed in a canister held for 147 days while the longest stored canister resulted in a 5% hydrogen concentration. The oxygen concentration never exceeded 0.5 %, and the primary backfill was >80% argon, meaning there was no flammability risk. Radiolytic hydrogen was also observed in wet pool storage, where the vented canisters discharged a portion of the water backfill as a result of gas production. The 344 canisters (268 fuel debris, 62 filter, and 12 knockout type) were dewatered, loaded in groups of seven into a double barrier shipping cask, and transported to the U.S. Department of Energy site in Idaho for 10 years of pool storage.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Hanford Waste Treatment Plant Effluent Management Facility Stack Effluent Monitoring: Sampling Probe Location Qualification Evaluation

The Hanford Tank Waste Treatment and Immobilization Plant Effluent Management Facility (EMF) stack monitor location was qualified using a combination of scale model stacks to mitigate the risk of identifying that the sampling location does not meet the qualification criteria on the full-scale stack. The LV-S1 scale model stack was used as a baseline, augmented by the LB-S1 and LV-S2 scale model stacks to address the Direct Feed Low Activity Waste Effluent Management Facility Vessel Vent Process (DVP) injection into the main Active Confinement Ventilation (ACV) system duct. As required by the American National Standards Institute/Health Physics Society (ANSI/HPS) N13.1-1999 standard, the scale model and its sampling locations were geometrically similar to the actual stack, and the Reynolds numbers for both the actual and model stacks were >10,000. An additional criterion is that the product of the hydraulic diameter and mean velocity (DV) of the full-scale stack must be between 1/6 DV and 6 DV of the scale model stack tests. The LV-S1, LB-S1, and LV-S2 scale model stack tests have met the criteria of the ANSI/HPS N13.1-1999 standard to demonstrate the stack sampling locations are well mixed. Verification tests of the EMF stack were performed at normal operating conditions. The minimum 1/6 DV value and the maximum 6 DV value from the scale model testing determine the range of stack flow rates for which the full-scale stack may be operated while remaining in compliance with the stack verification criterion. A practical range for the full-scale stack qualification uses the average DV through 6 DV from the scale model tests to compute the corresponding flow rates. Table S1 lists the operating flow rate along with the average and maximum qualified stack flow rate based on the LV-S1 scale model DV values. The operating flow is below the maximum qualified stack flow, which means that the scale model test results are acceptable for stack qualification. The remaining criteria for the stack verification to be considered valid involve the flow angle and velocity uniformity results. First, the flow angle at the full-scale stack must be ≤20°. Second, the velocity uniformity at the full-scale stack must be ≤20% coefficient of variance (COV). Finally, the velocity uniformity results for the actual and scale model stack tests must agree within 5% COV. These criteria were met through the full-scale stack test at the EMF. Flow angle results were <5°; all flow angle results were within the ≤20° criterion. The velocity uniformity results for each test condition ranged between 2.2% COV and 4.3% COV, all of which were within the range of the target % COV values from the scale model tests on the LV-S1, LB-S1, and LV S2 scale models. Based on these stack verification test results, the EMF filtered exhaust stack sampling location meets the qualification criteria provided in the ANSI/HPS N13.1-1999 standard for all planned fan operating configurations. This includes each combination of ACV fans with DVP exhausters. Further changes to the system configuration or operating conditions that are outside the qualified flow rates described in this report may require additional tests or analyses to determine compliance with the standard.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Salt Vessel-Sample Generator Interface

The goal of the salt sampling program at Argonne is to develop and deploy automated molten salt sampling approaches for interfacing relevant unit operations with salt analysis to improve the timeliness and accuracy of sampling-based accountancy measurements. One technology under development is a vacuum sampler loop module. In this system, molten salt is drawn from a process vessel through a heated sampling line and into a charge vessel. Next, one or more samples are split from the volume in the charge vessel and the remaining salt is returned to the process. The vacuum sampler loop module is being developed to interface with other sample processing and analysis modules to enable rapid at-line sample characterization. The main purpose of the vacuum sampling loop module is to enable the collection of samples that are more representative of the bulk salt by replacing traditional point samplers (i.e., dip probes) with a sampling approach that captures a larger cross section of salt. Additionally, the vacuum sampling approach eliminates the risk of dross contamination of samples and avoids the use of moving parts in the salt. Two methods of interfacing the vacuum sampling loop with a precision pneumatic sample generator were investigated in FY21. This report covers the testing of fluidic coupling between the two modules. Two iterations of the fluidically coupled modules were tested. The first iteration system coupled the two modules using a freeze valve to seal the vacuum sampler during filling and to control flow into the pneumatic sample generator. While this integrated system functioned as intended, some changes were implemented to make the system more robust and better suited to remote deployment. Specifically, the system was made to be more modular and active control of the vacuum filling operation was replaced with a passive control mechanism. For passive filling, the salt charge vessel was vented to a small gas tank that was at negative pressure, causing salt to be drawn into the vessel until the force of the fluid head was in equilibrium with the gas pressure. The passive control system performed well and will be used in future iterations. Another change in the second system was a newly configured pneumatic sample generator in which sample ejection occurred through a hole in the reservoir’s stainless-steel side wall instead of through a non-wetted sapphire orifice on the bottom. This alternate configuration may be better suited for near-process deployment because it enables on-line orifice maintenance and an orifice bypass drain back to the process. A third change in the second iteration system was the transition to a two-chamber charge vessel which split off a fraction of the sampled salt as a liquid aliquot. The goal was to create a buffer mechanism that would allow reproducible aliquoting of samples, independently of variability in the charge vessel fill height. While the two-chamber design was functional, the sample size reproducibility was below target values. To improve reproducibility and overcome many of the impediments to remote deployment of the vacuum sampling loop module, separate work was conducted to replace the two-chamber liquid aliquoting mechanism with aliquoting into single-use sample tubes. Solid salt transfer in the sample tubes will replace fluidic coupling for integrating the vacuum sampler with downstream modules. Because the proposed operations can all be executed with simple overhead actuation mechanisms or other existing hot-cell technology, there will be no need for large investments in novel hot cell sample handling technologies using this alternate approach. As such, near-term deployment of the vacuum sampling technology will be achievable. This new approach for automated coupling of sample tubes with down-stream modules is covered in a separate FY21 report, and a remotely operated version of the vacuum sampler loop module with the tube aliquoting feature is planned for FY22.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Electrocatalytically Upgrading Methane to Benzene in a Highly Compacted Microchannel Protonic Ceramic Membrane Reactor

This project aims to develop highly compacted microchannel protonic ceramic membrane reactors (HCM-PCMRs) for efficient and cost-effective methane dehydrogenation to aromatics (MDA, e.g., benzene). The integration of single-atom catalysis, electrocatalysis, membrane catalysis, membrane separation, and advanced manufacturing is designed to fulfill this goal. This project's success will ultimately develop a new cost-effective, efficient, and highly compacted infrastructure technology to address the flare and venting issue during oil and gas operations and other gas-to-liquid technologies. The key objectives for the three budget periods (BPs) are as follows.

02 PETROLEUM↗

Measuring 3D Profilometry of SAVY-4000 Nuclear Material Storage Containers: Novacam TubeInspect Capabilities Report

The SAVY-4000 container series is a general-purpose interim storage container for nuclear materials, developed and maintained by Los Alamos National Laboratory (LANL). It is the first vented, general-use nuclear material container to be demonstrated as meeting the requirements outlined in DOE M 441.1-1, the Nuclear Material Packaging Manual. Due to the challenging radiation, thermal, and corrosive storage conditions that the SAVY containers must endure, continuous surveillance techniques are employed to ensure the containers meet all safety standards and specifications. These inspections are typically performed by human operators, who check for issues such as corrosion, O-ring deterioration, corrosion, filter integrity, and potential manufacturing defects. However, human inspections alone are not sufficient, and automated inspection technologies, such as the ATIS system, as well as other automated systems are also utilized. The MicroCam TubeInspect, developed by Novacam Technologies Inc., is designed to address the challenges of understanding how manufacturing variations in the SAVY-4000 container series may affect performance. It is a 3D profilometry measurement system that enables detailed analysis of surface features, including defects, surface roughness, and manufacturing variations. This advanced tool significantly enhances rapid surveillance techniques for both pristine and used containers. In this study, container properties such as surface roughness, thickness, and geometric attributes like circularity are measured for SAVY-4000 containers. Artificially corroded or dented containers are examined to demonstrate the MicroCam's ability to quantify defects. A sensitivity analysis is also conducted, comparing the MicroCam results to those obtained using more precise instruments such as confocal microscopy. This comparison aims to provide valuable insights into container quality, durability, and potential improvements in manufacturing processes.

42 ENGINEERING↗

Characterization of MC&A for the Molten Salt Fuel Cycle

Advanced reactor developers are exploring diverse reactor designs, including molten salt reactors (MSRs). These advanced reactors are considered for wider applications and a range of deployment locations, including supporting the integration of renewable energy sources in the grid. There are three main types of MSRs: (1) reactors in which the fuel salt freely circulates within the core; (2) reactors with the fuel salt contained within vented fuel tubes; and (3) reactors that use molten salt solely as a coolant, with the fuel in a separate, solid form. In this document, the term MSR refers specifically to the first two types, which use fuel salt—special nuclear material (enriched uranium, plutonium, and 233 U) in chloride or fluoride form mixed with chloride- or fluoride-based carrier salt in a peritectic mixture—as the primary medium for fission. The composition of fuel salt, both at startup and for makeup or refueling, varies depending on the MSR design and the chosen fuel cycle approach, which can be either once-through or closed. For MSRs, a variety of fuel cycle approaches (e.g., U, U–Pu, U–Pu–TRU, U–Th, U–Pu–Th) are being considered. Fuel in MSRs is much different than traditional solid fuel, including its preparation. The uniqueness warrants investigation into characterizing fuel preparation processes, known as fuel salt synthesis . This effort characterized major fuel preparation and synthesis processes, identifying temperature, equipment, and environmental requirements for uranium-, plutonium-, and thorium-based fuel preparation and synthesis. Because MSR fuel salt synthesis facilities handle special nuclear material in loose, bulk form, a material control and accounting plan will be required for licensing from the US Nuclear Regulatory Commission or under the US Department of Energy authorization. This effort serves as a foundation to investigate material control and accounting approaches for synthesis facilities, including determining measurement points and techniques. Because several MSR developers are planning demonstration facilities in the coming years, this effort will support stakeholders with preparing or reviewing material control and accounting plans for providing assurance that all special nuclear material is accounted for at fuel salt synthesis facilities. This report was produced for Materials Protection, Accounting, and Control Technologies (MPACT) program under the US Department of Energy (DOE), Office of Nuclear Energy, Nuclear Fuel Cycle and Supply Chain.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

The Hunga Volcanic Eruption Atmospheric Impacts Report

On 15 January 2022 a highly explosive eruption of the Hunga volcano occurred in the Kingdom of Tonga in the South Pacific Ocean (175°24’ W, 20°33’ S). The Volcanic Explosivity Index (VEI) 6 eruption originated from a shallow submarine vent, making it distinct from large subaerial eruptions of recent decades (e.g., 1982 El Chichón, 1991 Mt. Pinatubo). In particular, seawater enhanced explosivity and dampened sulfur dioxide (SO 2 ) emissions. The eruption was the culmination of ~1 month of precursory activity; however, the timing and size of the eruption were unexpected, partly due to the challenges of monitoring submarine volcanoes. The stratospheric hydration caused by the eruption was unprecedented in magnitude, altitude, and duration in the satellite record. This Executive Summary reflects the current assessment of the Hunga eruption and its impact on the climate system. We report key observations of the eruption and its aftermath, as well as simulations of its impact by global chemistry-climate models. The Hunga eruption had an unprecedented impact on the stratosphere and mesosphere due to the plume height and large water content, which increased the global stratospheric water vapour burden by 10%. Most of this water has remained in the atmosphere into 2025. However, Hunga’s net impact on surface climate was small compared to that of earlier large-magnitude volcanic eruptions, due to limited sulfate aerosol loading in the stratosphere and the high altitude of the water vapour injection.

58 GEOSCIENCES↗

Methanol from Integrated Direct Air Capture and Ceramic Electrolysis (MIDACE)

The Methanol from Integrated Direct Air Capture and Ceramic Electrolysis (MIDACE) project advanced a novel system concept for integrating pressurized co-electrolysis of steam and crude carbon dioxide captured directly from ambient air using a sorbent technology. The co-electrolysis produced syngas provides feedstock for a gas-to-liquid methanol synthesis reactor. The system recovers waste heat from the reactor and electrolyzer into regenerating the direct air capture sorbent. The purpose of the project was to demonstrate critical integration elements of the design and perform a technical study illustrating how a large-scale installation could achieve the $800/ton program target for green methanol production. The concept addresses the program objective to consolidate operations by combining crude CO 2 cleanup, hydrogen production, and partial CO 2 reduction steps within a carbon tolerant high temperature electrolyzer. The design lowers costs by simplifying the methanol recovery cycle, reducing carbon losses from venting, reducing sensitivity to catalyst selectivity, and avoiding syngas compression.

10 SYNTHETIC FUELS↗

One Earth Energy CO 2 Capture Facility FEED Study and Class 4 Cost Estimate

The One Earth Energy (OEE) plant in Gibson City, Illinois produces ethanol through a corn fermentation process. For this project, the maximum possible ethanol production rate for this facility is 160 million gallons per year (MMgal/yr) based on discussions with plant personnel regarding recent annual production rates and any foreseeable plans or possibilities to increase ethanol production at this facility. Yeast ferments the corn mash to produce ethanol and produces carbon dioxide (CO 2 ) as a by-product at the same time. The CO 2 bubbles out of the mash and flows through a packed bed water scrubber to remove volatile organic compounds before the gas vents to atmosphere. CO 2 will be captured after it has passed through the existing scrubber.

09 BIOMASS FUELS↗

Audible Noise Modeling of Hydrogen Release Sonic Hazards in Rail Maintenance Facilities

This study implemented validated literature models to predict audible noise due to pressurized gaseous hydrogen releases through a thermally-activated pressure relief device (TPRD) and attached vent stack. A literature survey discovered limited hydrogen-specific noise prediction models validated by experiments. However, empirical noise prediction models for air flowing through pipes and valves were identified. These empirical models were used to predict noise levels and compared against hydrogen noise data reported in two studies: one experimental study of noise from hydrogen leaking through a pipe and another which modeled hydrogen flowing through a solenoid valve during a fuel cell vehicle refueling. The valve flow model was then applied to predict noise for hydrogen releases through a TPRD. Results show that hydrogen releases through a TPRD can produce harmful noise levels varying from 134 to 150 dB. However, further model validation and additional experimental data are needed to improve prediction confidence and accuracy.

08 HYDROGEN↗

Draft Impacts: Modeling and Lab Validation (CRADA Final Report)

Chimney draft is a significant source of variability in real-world wood heater performance, yet laboratory tests conducted for certification do not capture this variability. Because draft varies with climate, chimney height, and home conditions, a heater that performs well in the lab can perform quite differently when installed in a home. Until now, wood heater manufacturers and installers have lacked the tools needed to anticipate how draft will vary across real installations or to advise on corrective measures when draft is too low or too high. The goal of this project was to develop and validate an open-source draft prediction tool for cordwood heater chimney systems. Over 18 months, Lawrence Berkeley National Laboratory (LBNL) and the Hearth, Patio & Barbecue Association (HPBA) collaborated to build a physics-based, Python tool that predicts how chimney draft evolves during operation, from ignition through steady burning. HPBA convened a stakeholder group of manufacturers and venting experts who provided feedback throughout development. LBNL validated the tool against laboratory measurements from a catalytic and a non-catalytic cordwood heater operated across a range of chimney heights and room-pressure conditions.

42 ENGINEERING↗

Waste Heat Powered Ammonia Absorption Refrigeration Unit for LPG Recovery

An emerging DOE-sponsored technology has been deployed. The technology recovers light ends from a catalytic reformer plant using waste heat powered ammonia absorption refrigeration. It is deployed at the 17,000 bpd Bloomfield, New Mexico refinery of Western Refining Company. The technology recovers approximately 50,000 barrels per year of liquefied petroleum gas that was formerly being flared. The elimination of the flare also reduces CO2 emissions by 17,000 tons per year, plus tons per year reductions in NOx, CO, and VOCs. The waste heat is supplied directly to the absorption unit from the Unifiner effluent. The added cooling of that stream relieves a bottleneck formerly present due to restricted availability of cooling water. The 350oF Unifiner effluent is cooled to 260oF. The catalytic reformer vent gas is directly chilled to minus 25oF, and the FCC column overhead reflux is chilled by 25oF glycol. Notwithstanding a substantial cost overrun and schedule slippage, this project can now be considered a success: it is both profitable and highly beneficial to the environment. The capabilities of directly-integrated waste-heat powered ammonia absorption refrigeration and their benefits to the refining industry have been demonstrated.

01 COAL, LIGNITE, AND PEAT↗

Radionuclide Air Emission Report for 2007

Berkeley Lab operates facilities where radionuclides are handled and stored. These facilities are subject to the U.S. Environmental Protection Agency (EPA) radioactive air emission regulations in Code of Federal Regulations (CFR) Title 40, Part 61, Subpart H (EPA 1989). The EPA regulates radionuclide emissions that may be released from stacks or vents on buildings where radionuclide production or use is authorized or that may be emitted as diffuse sources. In 2007, all Berkeley Lab sources were minor stack or building emissions sources of radionuclides (sources resulting in a potential dose of less than 0.1 mrem/yr [0.001 mSv/yr]), there were no diffuse emissions, and there were no unplanned emissions. Emissions from minor sources either were measured by sampling or monitoring or were calculated based on quantities received for use or produced during the year. Using measured and calculated emissions, and building-specific and common parameters, Laboratory personnel applied the EPA-approved computer code, CAP88-PC, Version 3.0, to calculate the effective dose equivalent to the maximally exposed individual (MEI). The effective dose equivalent from all sources at Berkeley Lab in 2007 is 1.2 x 10{sup -2} mrem/yr (1.2 x 10{sup -4} mSv/yr) to the MEI, well below the 10 mrem/yr (0.1 mSv/yr) EPA dose standard. The location of the MEI is at the University of California (UC) Lawrence Hall of Science, a public science museum about 1500 ft (460 m) east of Berkeley Lab's Building 56. The estimated collective effective dose equivalent to persons living within 50 mi (80 km) of Berkeley Lab is 3.1 x 10{sup -1} person-rem (3.1 x 10{sup -3} person-Sv) attributable to the Lab's airborne emissions in 2007.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

Oilfield Flare Gas Electricity Systems (OFFGASES Project)

The Oilfield Flare Gas Electricity Systems (OFFGASES) project was developed in response to a cooperative agreement offering by the U.S. Department of Energy (DOE) and the National Energy Technology Laboratory (NETL) under Preferred Upstream Management Projects (PUMP III). Project partners included the Interstate Oil and Gas Compact Commission (IOGCC) as lead agency working with the California Energy Commission (CEC) and the California Oil Producers Electric Cooperative (COPE). The project was designed to demonstrate that the entire range of oilfield 'stranded gases' (gas production that can not be delivered to a commercial market because it is poor quality, or the quantity is too small to be economically sold, or there are no pipeline facilities to transport it to market) can be cost-effectively harnessed to make electricity. The utilization of existing, proven distribution generation (DG) technologies to generate electricity was field-tested successfully at four marginal well sites, selected to cover a variety of potential scenarios: high Btu, medium Btu, ultra-low Btu gas, as well as a 'harsh', or high contaminant, gas. Two of the four sites for the OFFGASES project were idle wells that were shut in because of a lack of viable solutions for the stranded noncommercial gas that they produced. Converting stranded gas to useable electrical energy eliminates a waste stream that has potential negative environmental impacts to the oil production operation. The electricity produced will offset that which normally would be purchased from an electric utility, potentially lowering operating costs and extending the economic life of the oil wells. Of the piloted sites, the most promising technologies to handle the range were microturbines that have very low emissions. One recently developed product, the Flex-Microturbine, has the potential to handle the entire range of oilfield gases. It is deployed at an oilfield near Santa Barbara to run on waste gas that is only 4% the strength of natural gas. The cost of producing oil is to a large extent the cost of electric power used to extract and deliver the oil. Researchers have identified stranded and flared gas in California that could generate 400 megawatts of power, and believe that there is at least an additional 2,000 megawatts that have not been identified. Since California accounts for about 14.5% of the total domestic oil production, it is reasonable to assume that about 16,500 megawatts could be generated throughout the United States. This power could restore the cost-effectiveness of thousands of oil wells, increasing oil production by millions of barrels a year, while reducing emissions and greenhouse gas emissions by burning the gas in clean distributed generators rather than flaring or venting the stranded gases. Most turbines and engines are designed for standardized, high-quality gas. However, emerging technologies such as microturbines have increased the options for a broader range of fuels. By demonstrating practical means to consume the four gas streams, the project showed that any gases whose properties are between the extreme conditions also could be utilized. The economics of doing so depends on factors such as the value of additional oil recovered, the price of electricity produced, and the alternate costs to dispose of stranded gas.

02 PETROLEUM↗

Optimized, Competitive Supercritical-CO2 Cycle GFR for Gen IV Service

An overall plant design was developed for a gas-cooled fast reactor employing a direct supercritical Brayton power conversion system. The most important findings were that (1) the concept could be capital-cost competitive, but startup fuel cycle costs are penalized by the low core power density, specified in large part to satisfy the goal of significatn post-accident passive natural convection cooling; (2) active decay heat removal is preferable as the first line of defense, with passive performance in a backup role; (3) an innovative tube-in-duct fuel assembly, vented to the primpary coolant, appears to be practicable; and (4) use of the S-Co2 GFR to support hydrogen production is a synergistic application, since sufficient energy can be recuperated from the product H2 and 02 to allow the electrolysis cell to run 250 C hotter than the reactor coolant, and the water boilers can be used for reactor decay heat removal. Increasing core poer density is identified as the top priority for future work on GFRs of this type.

08 HYDROGEN↗