Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Upgrade”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,351 records · Page 75

Designing an innovation system to support profitable electro- and bio-catalytic carbon upgrade

Carbon capture, utilisation, and storage (CCUS) can mitigate an estimated 14–20% of CO 2 emissions by 2050. Here, we evaluate an integrated electrocatalysis and biocatalysis CCUS pathway, using externally-supplied renewable electricity to convert over 12 MtCO 2 to poly(3-hydroxybutyrate) via methanol and formate intermediates. A techno-economic and policy-innovation analysis provides insight into global CCUS innovation. Results suggest that innovation should focus on improving methanol faradaic efficiency, formate biocatalysis efficiency, electrocatalysis current density, and catalyst performance. Methanol and formate composition influences performance, but higher formate content can improve economics by US$3.8B over a 30 year lifetime. Profitable scenarios hinge on reducing methanol separation costs – through innovation or reduced energy usage – along with cheap renewable electricity and/or carbon pricing. Our evaluation of the global innovation status signifies that coordinated strategies are required to realise emissions cuts from CCUS. Innovation can be spurred by targeted investments and policies that promote emissions reductions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Evolution of the ATLAS TDAQ online software framework towards Phase-II upgrade: Use of Kubernetes as an orchestrator of the ATLAS Event Filter computing farm

The ATLAS experiment at the LHC at CERN continuously evolves its TDAQ system to meet the challenges of new physics goals and technological advancements. As ATLAS prepares for the Phase-II Run 4 of the LHC, significant enhancements in the TDAQ Controls and Configuration (TDAQ-CC) tools have been designed to ensure efficient data collection, processing, and management. This abstract presents the evolution of ATLAS TDAQ-CC system leading up to Phase-II Run 4. As part of the evolution towards Phase-II, Kubernetes has been chosen to orchestrate the Event Filter (EF) farm. By leveraging Kubernetes, ATLAS can dynamically allocate computing resources, scale processing capacity in response to changing data taking conditions and ensure high availability of data processing services. The integration of the Kubernetes with the TDAQ Run Control framework enables perfect synchronisation between the experiment’s data acquisition components and the computing infrastructure. We will discuss the architectural considerations and implementation challenges involved in Kubernetes integration with the ATLAS TDAQ-CC system. We will highlight the benefits of using Kubernetes as an EF farm orchestrator, including improved resource utilization, enhanced fault tolerance, and simplified deployment and management of data processing workflows. In addition, we will report on the extensive testing of Kubernetes that was conducted using a farm of 2500 servers within the experiment data taking environment, demonstrating its scalability and robustness in handling the demands of the ATLAS TDAQ system for Phase-II. The adoption of Kubernetes represents a significant step forward in the evolution of ATLAS TDAQ-CC system, aligning with industry best practices in container orchestration.

Corso Radu, Alina [Univ. of California, Irvine, CA↗

Upgraded vacuum arc ion source for metal ion implantation

Vacuum arc ion sources have been made and used by a large number of research groups around the world over the past twenty years. The first generation of vacuum arc ion sources (dubbed ''Mevva,'' for metal vapor vacuum arc) was developed at Lawrence Berkeley National Laboratory in the 1980s. This paper considers the design, performance parameters, and some applications of a new modified version of this kind of source which we have called Mevva-V.Ru. The source produces broad beams of metal ions at an extraction voltage of up to 60 kV and a time-averaged ion beam current in the milliampere range. Here, we describe the Mevva-V.Ru vacuum arc ion source that we have developed at Tomsk and summarize its beam characteristics along with some of the applications to which we have put it. We also describe the source performance using compound cathodes.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Operating The Upgraded NSTX HHFW Antenna Array In An Environment With Li-coated Surfaces

The single-feed, end-grounded straps of the NSTX 12-strap HHFW antenna array have been replaced with double-feed, center-grounded straps to reduce the voltages in the vicinity of the Faraday shield (FS) for a given strap current. The strap spacings to the FS and to the back plate were increased by 3 mm to decrease the electric fields for a given voltage. The electric fields near the FS have been roughly halved for the same strap currents, permitting a direct examination of the roles that internal fields play in determining antenna power limits in plasmas. Extensive RF/plasma conditioning of the antenna was required to remove enough of the evaporated Li deposits from prior wall conditioning to permit coupling in excess of 4 MW to L- and H-mode plasmas in 2009. Most arcs were associated with expulsion of Li from the FS/antenna frame surfaces. The center-grounded straps were less susceptible to arcing during ELMing H-mode plasmas. Reliable operation above 2 MW was difficult after the installation of the Liquid Lithium Divertor (LLD) in 2010. Li-compound 'dust' was found in the antennas after this run and is believed to have contributed to the reduced power limit.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Upgrading the sensitivity of spectroscopy gas analysis with application of supersonic molecular beams

We propose an approach to increase a sensitivity of microwave and THz spectroscopy, that involves application of supersonic molecular beams. The key advantage offered by such an approach is that a gas temperature can be decreased along with an increase in the gas density, which results in a much greater number of molecules interacting with radiation and, hence, in a higher absorption coefficient. This effect has been demonstrated experimentally on supersonic CO and NO beams, using a phase manipulation microwave spectrometer. The absorption coefficient was found to be three orders of magnitude higher than the value of gas absorption coefficient in a standard 1-m long cell at room temperature.

74 ATOMIC AND MOLECULAR PHYSICS↗

Upgrade of the MIT Linear Electrostatic Ion Accelerator (LEIA) for nuclear diagnostics development for Omega, Z and the NIF

The MIT Linear Electrostatic Ion Accelerator (LEIA) generates DD and D{sup 3}He fusion products for the development of nuclear diagnostics for Omega, Z, and the National Ignition Facility (NIF). Significant improvements to the system in recent years are presented. Fusion reaction rates, as high as 10{sup 7} s{sup -1} and 10{sup 6} s{sup -1} for DD and D{sup 3}He, respectively, are now well regulated with a new ion source and electronic gas control system. Charged fusion products are more accurately characterized, which allows for better calibration of existing nuclear diagnostics. In addition, in situ measurements of the on-target beam profile, made with a CCD camera, are used to determine the metrology of the fusion-product source for particle-counting applications. Finally, neutron diagnostics development has been facilitated by detailed Monte Carlo N-Particle Transport (MCNP) modeling of neutrons in the accelerator target chamber, which is used to correct for scattering within the system. These recent improvements have resulted in a versatile platform, which continues to support the existing nuclear diagnostics while simultaneously facilitating the development of new diagnostics in aid of the National Ignition Campaign at the National Ignition Facility.

43 PARTICLE ACCELERATORS↗

Exploration of ion temperature profile measurements at JET using the upgraded neutron profile monitor

The neutron profile monitor (NPM), routinely used at the Joint European Torus for neutron emissivity profile measurements, consists of two fan-shaped arrays of collimators and each line of sight (LOS) is equipped with a NE213 liquid organic scintillator for simultaneous measurements of the 2.5 MeV and 14 MeV neutrons. A digital system developed in ENEA has replaced the analog acquisition electronics and now enables the NPM to perform spatially resolved neutron spectrometry by providing neutron pulse height spectra (PHS) for each LOS. However, the NPM was not originally designed as a spectrometer and, therefore, lacks several key features, such as detailed measurements of the detector response functions and the presence of detector stability monitors. We present a proof of principle of ion temperature profile measurements derived from the NPM PHS in high plasma current discharges using simulated detector response functions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Prospects for the Thomson scattering system on NSTX-Upgrade

The paper discusses the projected configuration of the Thomson system on the National Spherical Torus Experiment (NSTX-U). In this paper, we discuss the projected configuration of the Thomson system on NSTX-U. More specifically, we determine, through both optical modeling of the collection optics and in-vessel measurements, that the collecting fibers are to be displaced by at most 1 cm toward the imaging plane along the optical axis. Finally, we estimate the performance of the Thomson system in measuring the electron temperature for NSTX-U discharges.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

150 {mu}A 18F{sup -} target and beam port upgrade for the IBA 18/9 cyclotron

A high power ({approx}3 kW) target platform has been developed for the IBA 18/9 cyclotron. New designs for the airlock, collimator and target subsystems have been fabricated and deployed. The primary project goal is reliable commercial production of 18F{sup -} at 150 {mu}A or greater, while secondary goals include improving serviceability and extending service intervals relative to OEM systems. Reliable operation in a production environment has been observed at beam currents up to 140 {mu}A. Challenges include ion source lifetime and localized peaking in the beam intensity distribution.

43 PARTICLE ACCELERATORS↗

SuperADAM: Upgraded polarized neutron reflectometer at the Institut Laue-Langevin

A new neutron reflectometer SuperADAM has recently been built and commissioned at the Institut Laue-Langevin, Grenoble, France. It replaces the previous neutron reflectometer ADAM. The new instrument uses a solid state polarizer/wavelength filter providing a highly polarized (up to 98.6%) monochromatic neutron flux of 8 Multiplication-Sign 10{sup 4} n cm{sup -2} s{sup -1} with monochromatization {Delta}{lambda}/{lambda}= 0.7% and angular divergence {Delta}{alpha}= 0.2 mrad. The instrument includes both single and position sensitive detectors. The position sensitive detector allows simultaneous measurement of specular reflection and off-specular scattering. Polarization analysis for both specular reflection and off-specular scattering is achieved using either mirror analyzers or a {sup 3}He spin filter cell. High efficiency detectors, low background, and high flux provides a dynamic range of up to seven decades in reflectivity. Detailed specifications and the instrument capabilities are illustrated with examples of recently collected data in the fields of thin film magnetism and thin polymer films.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Optical reflectivity improvement by upgrading metallic glass film quality

The effects of atomic-defect and free-volume amounts of metallic glassy film on the optical reflectivity and mechanical properties of the sputtered metallic glass thin films are explored. With a lower Ar working pressure and the proper post-annealing at temperatures slightly lower than the glass-transition temperature T{sub g}, film free volumes and defects would reduce, resulting in better atomic bonding and higher film hardness/modulus, which in turn leads to lower electric resistivity and higher optical reflectivity. Annealing above T{sub g} would induce crystalline structure which would lead to competition with the optical transition of the Drude free electrons and hinder the optical reflectivity in the visible range.

36 MATERIALS SCIENCE↗

Average and recommended half-life values for two neutrino double beta decay: Upgrade-2013

All existing positive results on two neutrino double beta decay in different nuclei were analyzed. Using the procedure recommended by the Particle Data Group, weighted average values for half-lives of {sup 48}Ca, {sup 76}Ge, {sup 82}Se, {sup 96}Zr, {sup 100}Mo, {sup 100}Mo−{sup 100}Ru (0{sub 1}{sup +}), {sup 116}Cd, {sup 130}Te, {sup 136}Xe, {sup 150}Nd, {sup 150}Nd−{sup 150}Sm (0{sub 1}{sup +}) and {sup 238}U were obtained. Existing geochemical data were analyzed and recommended values for half-lives of {sup 128}Te and {sup 130}Ba are proposed. I recommend the use of these results as the most currently reliable values for half-lives.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Upgrade of the gas flow control system of the resistive current leads of the LHC inner triplet magnets: Simulation and experimental validation

The 600 A and 120 A circuits of the inner triplet magnets of the Large Hadron Collider are powered by resistive gas cooled current leads. The current solution for controlling the gas flow of these leads has shown severe operability limitations. In order to allow a more precise and more reliable control of the cooling gas flow, new flowmeters will be installed during the first long shutdown of the LHC. Because of the high level of radiation in the area next to the current leads, the flowmeters will be installed in shielded areas located up to 50 m away from the current leads. The control valves being located next to the current leads, this configuration leads to long piping between the valves and the flowmeters. In order to determine its dynamic behaviour, the proposed system was simulated with a numerical model and validated with experimental measurements performed on a dedicated test bench.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High spatial resolution upgrade of the electron cyclotron emission radiometer for the DIII-D tokamak

The 40-channel DIII-D electron cyclotron emission (ECE) radiometer provides measurements of T{sub e}(r,t) at the tokamak midplane from optically thick, second harmonic X-mode emission over a frequency range of 83–130 GHz. The frequency spacing of the radiometer's channels results in a spatial resolution of ∼1–3 cm, depending on local magnetic field and electron temperature. A new high resolution subsystem has been added to the DIII-D ECE radiometer to make sub-centimeter (0.6–0.8 cm) resolution T{sub e} measurements. The high resolution subsystem branches off from the regular channels’ IF bands and consists of a microwave switch to toggle between IF bands, a switched filter bank for frequency selectivity, an adjustable local oscillator and mixer for further frequency down-conversion, and a set of eight microwave filters in the 2–4 GHz range. Higher spatial resolution is achieved through the use of a narrower (200 MHz) filter bandwidth and closer spacing between the filters’ center frequencies (250 MHz). This configuration allows for full coverage of the 83–130 GHz frequency range in 2 GHz bands. Depending on the local magnetic field, this translates into a “zoomed-in” analysis of a ∼2–4 cm radial region. Expected uses of these channels include mapping the spatial dependence of Alfven eigenmodes, geodesic acoustic modes, and externally applied magnetic perturbations. Initial T{sub e} measurements, which demonstrate that the desired resolution is achieved, are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗