Transient Stability Study of a Real-World Microgrid with 100% Renewables: Preprint

This paper performs a transient stability study of a real-world microgrid with 100% renewables to fully understand the stability and reliability of the microgrid under various dynamic scenarios. In particular, the operation of multiple grid-forming (GFM) and grid-following (GFL) inverters in such a power system is not well understood under dynamic operation conditions, such as islanding and black start; therefore, in this paper, the full-scale electromagnetic transient modeling of the microgrid is developed to investigate the stability of the system under various dynamic operating conditions and to identify potential reliability risks. The PSCAD/EMTDC simulation with the high-fidelity model provides helpful insights into the optimal operation modes of GFM and GFL inverters as well as the stability and reliability of the microgrid, which gives good references for the field deployment in terms of inverter configuration and coordination as well as the capabilities of black start and unplanned islanding.

100% renewable microgrid↗

SENSITIVITY STUDIES OF HEATER ROD DESIGN FOR TRANSIENT CRITICAL HEAT FLUX EXPERIMENTS IN TREAT

An important area of reactor safety is the cladding-to-coolant heat transfer under fast transient conditions. These conditions can occur during events such as a reactivity-initiated accident (RIA). In this paper we present the work performed under a laboratory directed research and development (LDRD) project, headed by Idaho National Laboratory (INL). The goal was to develop a test matrix to inform on the design of a borated steel heater rod that will induce critical heat flux (CHF) within an experimental capsule filled with water, using the TREAT facility, when submitted to a power pulse. The energy deposition in the rod and occurrence of CHF were identified as the most important key Figures of Merit (FoMs) used in the design process. Energy deposition was varied by using different pulse characteristics and various boron concentrations in the rod. A power coupling factor (PCF) was determined for each boron concentration. A sensitivity study determined the lowest limiting PCF needed to induce CHF in water with different degrees of subcooling while keeping pressure constant. Boron concentrations between 0.1-1.54 wt.% were considered. Additionally, the value of CHF is also known to increase during a rapid transient. A CHF multiplier sensitivity study focused on an example case concluded that CHF is no longer exceeded when the value is between 2.6- and 2.9-times higher. Lastly, a self-shielding study was performed to determine whether a borated tube could be used in place of a solid borated rod. The study determined that the inner 1mm of the rod can essentially be excluded or instrumented without heat generation penalties.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Evaluating the Effects of Hydride Embrittlement and Pulse Width on Zircaloy Cladding Transient Performance

Pellet Cladding Mechanical Interaction is the primary failure mode for high burnup Zircaloy claddings in Light Water Reactor Reactivity Initiated Accidents. This failure mode is not seen in fresh and lower burnup fuels and is the result of environmental degradation of the cladding material and the unique loading condition on the cladding as a result of the sudden contact forces with the pellet. This paper describes work that is underway at the Idaho National Laboratory to better understand this failure mode by pre-hydriding fresh Zircaloy cladding. The pre-hydrided cladding is being mechanically characterized and will ultimately be used as part of an in-pile testing campaign at the TREAT reactor that will simulate the unique transient loading and heating conditions present in a Reactivity Initiated Accident. A description of the pre-hydriding and mechanical testing processes being followed, and initial results are presented followed by a description of the planned transient testing

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Capacitance Transients, Photoconductive Decay, and Impedance Spectroscopy on 19% to 22% Efficient Silicon Solar Cells

High efficiency silicon solar cells are characterized using current-voltage curves, electroluminescence imaging, impedance spectroscopy, capacitance transients, microwave photoconductive decay, and time-resolved photoluminescence imaging. The sample set is composed of cells from different manufacturers and includes an n-type silicon heterojunction (SHJ), an n-type passivated emitter rear totally diffused (PERT), and five different p-type passivated emitter rear contact (PERC) cells. Carrier lifetimes, both photoconductivity and photoluminescence, are measured co-located with the light excitation pulse and within the cell but away from the light spot. Luminescence intensity and excess carrier lifetimes correlate to cell voltage. The capacitance transient time constants correlate to the capacitance values extracted from impedance spectroscopy.

capacitance↗

Biodegradable transient battery built on core-double-shell zinc microparticle networks

A transient or biodegradable battery is provided having a filament structure that limits the speed of reaction allowing for a longer duration of battery power with a controlled current limit. In one embodiment, the filament may be constructed of zinc microparticles or nanoparticles having a thin outer insulation whereby a chemical reaction at the center core results in the progressive disintegration of the insulation revealing more core material. In one embodiment, microparticles or nanoparticles are coated with outer layers of chitosan and Al2O3 nanofilms, respectively, with designable discharge current and battery lifespan by controlling the exposed cross-sectional area of the zinc microparticle center core and the length of the filament, respectively. This novel structure of biodegradable battery provides improved control of battery life and power output, providing a promising solution to power transient medical implants.

Wang, Xudong↗

Out-of-Pile Testing and Instrumentation Transient Water Irradiation System

Current initiatives to increase the burnup of conventional nuclear fuels past the approximate 62 GWd/t limit have been spurred on by direct savings to refueling and waste storage. The technical justification for a new license limit requires extensive qualification through experimental testing. Unlike beginning-of-life fuels, high-burnup fuels are more susceptible to fuel fragmentation, relocation, and dispersal (FFRD), therefore more data is needed to characterize fuels under key accident scenarios. The Transient Reactor Test Facility (TREAT) located at the Idaho National Laboratory has developed a testing apparatus architecture to test fuels and claddings at prototypic conditions. The Transient Water Irradiation System (TWIST) is the latest iteration of a testing device capable of conducting loss of coolant accidents (LOCAs) in TREAT. The Out-of-Pile Testing and Instrumentation TWIST (OPTI-TWIST) is an electrically heated device that is analogous to TWIST. OPTI-TWIST allows for detailed instrumentation and thermal-hydraulic characterization. TWIST ultimately aims to conduct the most advanced in-situ diagnostics to evaluate FFRD in a prototypic LOCA. Moreover, it will explore the phenomenological bifurcation of a decay-energy heat up driven LOCA and a stored-energy heat up driven LOCA. The instrumentation suite includes conventional thermocouples and pressure transducers in addition to an electro impedance sensor, an acoustic emission sensor, an optical pressure sensor, and an optical pyrometer. Characterizing these instruments in OPTI-TWIST eliminates complications of irradiation effects while preserving extreme thermal-hydraulic conditions. Finally, benchmarking both devices to a thermal-hydraulic code like the Reactor Excursion and Leak Analysis Program (RELAP)5-3D provides a unique opportunity for iteration. Pre-test predictions and post-test interpretations inform the physical designs, operational procedures, test conditions, and instrumentation types and positions.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Assessing the Impact of Effective Thermal Conductivity on Gas-cooled Reactor Transients in RELAP5-3D

In block-type high-temperature gas-cooled reactors (HTGRs), coolant holes in blocks lead to a reduction in heat transfer through conduction. In systems codes like RELAP5-3D, we must account for this degradation by using an effective thermal conductivity (ETC). This presentation discusses a few ETC relationships and demonstrates the impact of ETC for the modular High-Temperature Gas-Cooled Reactor 350 MW -- a computational benchmark for HTGR modeling -- and for the High Temperature Test Facility (HTTF) -- an HTGR thermal hydraulics test facility. We demonstrate that the use of ETC leads to temperatures that are higher than the bulk thermal conductivity of the block material would yield, but these differences have no meaningful impact on the transient performance of the reactors. The ETC also reduces the cooldown rate, leading to more time at elevated temperatures. Overall, while accounting for ETC is important in capturing the physics of the reactor, it is not expected to have a meaningful impact on transient performance.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

A Neural Lyapunov Approach to Transient Stability Assessment in Interconnected Microgrids

We propose a neural Lyapunov approach to assessing transient stability in power electronic-interfaced microgrid interconnections. The problem of transient stability assessment is cast as one of learning a neural network-structured Lyapunov function in the state space. Based on the function learned, a security region is estimated for monitoring the security of interconnected microgrids in real-time operation. The efficacy of the approach is tested and validated in a grid-connected microgrid and a three-microgrid interconnection. A comparison study suggests that the proposed method can achieve a less conservative characterization of the security region, as compared with a conventional approach.

Huang, Tong↗

Analysis and Mitigation of Cascading Outages Using an Interaction Graph Addressing Transient Stability

Cascading outages of power systems pose great threats to system security and reliability, potentially leading to large-scale blackouts. For analysis and mitigation of cascading outages, this paper proposes a transient stability-incorporated interaction graph. This graph statistically quantifies the interactions among line outages and instabilities of generators, which can model propagation paths and patterns of cascading outages. Compared with an interaction graph that only models line outages, this new interaction graph provides important insights on how transient instability occurs along with cascading outages. It also offers more effective strategies for mitigating outage propagation. The proposed interaction graph can be constructed from datasets of historical or simulated cascading events. It is demonstrated on an NPCC 140-bus system with mitigation strategies.

Guo, Zhenping↗

A Generic and Multi-Functional Electromagnetic Transient Model for Grid-Following Inverter: Preprint

This article presents a generic and multi-functional electromagnetic transient (EMT) dynamic model of grid following (GFL) inverter-based resource (IBR) using the PSCAD TM software platform. The features of the developed model includes the flexibility in selecting various types and combinations of DC sources covering PV modules, battery modules, ideal DC source module, as well as flexibility in selecting either switched or averaged model of inverter. This model also covers exhaustive lists of controller logic covering open-loop/closed-loop PQ dispatch control, DC voltage and AC terminal voltage control along with the conventional current control designed in dq-domain, aB- domain and positive-negative sequence domain. Moreover, this model is equipped with the flexibility in selecting various types of current limiting schemes that includes saturation-based as well as latching-based current limiter, anti-windup protection. Moreover, the EMT model is agnostic to the MVA rating and is suitable for interfacing transmission systems by being complaint with the IEEE Std. 2800. The generality in the power circuits and the multi-functional options in operation and control of the developed EMT model makes it suitable for both academia and industry to study various power system aspects not limited to but such as fault behavior of GFL IBR and impacts on protection system, transient stability of a system interfaced with large number of GFL IBRs etc.

grid following inverter↗

Evaporator Temperature Transient Testing of a High-Performance Sodium Filled Heat Pipe

Heat pipes are two-phase heat transfer devices that enable passive removal of heat from the reactor core to the power conversion system in heat pipe-cooled microreactor designs. Experimental investigations of heat pipe transients are needed for technology demonstration, verification and validation of numerical codes, and the establishment of regulatory requirements. The Single Primary Heat Extraction and Removal Emulator (SPHERE) facility at Idaho National Laboratory (INL) serves as a platform for evaluating the dynamic response of high-temperature heat pipes under a variety of operating conditions. The present work details the experimental investigation of a high-performance, defined as over 2 kW sodium heat pipe subjected to rapid input power fluctuations induced by sudden changes in the evaporator temperature setpoint. In addition, the heat pipe was subjected to an asymmetrical heat load where a subset of heaters operated at 30% and 70% below their nominal power. These experimental conditions were chosen to simulate thermal and operational stresses expected to be encountered in microreactors to provide data on heat pipe behavior during such important transient events. Key data and performance metrics, including time series of temperatures and strains, axial temperature profiles, thermal response times, and heat transfer capabilities, the thermal output over thermal input, were reported and discussed. The results highlight the resilience of heat pipes, revealing their potential to maintain thermal stability and efficiency under varying power loads. Lastly, the paper concludes with a discussion on the significance of the results and their implications for future research.

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗

Impact of Nd ions on the chemical kinetic behavior of radiolytic transients in molten LiCl-KCl-NdCl3 salt mixtures

Pyrochemical reprocessing technologies can be used to recover valuable materials from used nuclear fuel (UNF), such as uranium. However, other critical materials, such as fission product neodymium, are challenging to recover from molten chloride eutectic mixtures (LiCl-KCl) due to the presence of multivalent states (Nd2+/Nd3+), disproportionation reactions, and re-dissolution in the molten chloride salt. Understanding, predicting, and controlling these processes is further complicated by the presence of ionizing radiation fields, for which little is known on the interaction of neodymium ions with the radiolytic transients (es– and Cl2.–) in molten LiCl-KCl salt mixtures. Here, chemical kinetics, from integrated electron pulse irradiation and transient absorption spectroscopy, are presented for the reaction of Nd3+ ions with es– and Cl2.– as a function of temperature (400–600 ?).

36 - MATERIALS SCIENCE↗

Radio and X-Ray Observations of the Luminous Fast Blue Optical Transient AT 2020xnd

We present deep X-ray and radio observations of the fast blue optical transient (FBOT) AT 2020xnd/ZTF 20acigmel at z = 0.2433 from 13 days to 269 days after explosion. AT 2020xnd belongs to the category of optically luminous FBOTs with similarities to the archetypal event AT 2018cow. AT 2020xnd shows luminous radio emission reaching L ν ≈ 8 × 10 29 erg s -1 Hz -1 at 20 GHz and 75 days post-explosion, accompanied by luminous and rapidly fading soft X-ray emission peaking at L X ≈ 6 × 10 42 erg s -1 . Interpreting the radio emission in the context of synchrotron radiation from the explosion's shock interaction with the environment, we find that AT 2020xnd launched a high-velocity outflow (v ~ 0.1c–0.2c) propagating into a dense circumstellar medium (effective $\dot{M}\approx {10}^{-3}\,{M}_{\odot }$ yr -1 for an assumed wind velocity of v w = 1000 km s -1 ). Similar to AT 2018cow, the detected X-ray emission is in excess compared to the extrapolated synchrotron spectrum and constitutes a different emission component, possibly powered by accretion onto a newly formed black hole or neutron star. These properties make AT 2020xnd a high-redshift analog to AT 2018cow, and establish AT 2020xnd as the fourth member of the class of optically luminous FBOTs with luminous multiwavelength counterparts.

79 ASTRONOMY AND ASTROPHYSICS↗

Electron thermalization and relaxation in laser-heated nickel by few-femtosecond core-level transient absorption spectroscopy

Direct measurements of photoexcited carrier dynamics in nickel are made using few-femtosecond extreme ultraviolet (XUV) transient absorption spectroscopy at the nickel M 2,3 edge. It is observed that the core-level absorption line shape of photoexcited nickel can be described by a Gaussian broadening (σ) and a red shift (ω s ) of the ground-state absorption spectrum. Theory predicts and the experimental results verify that after initial rapid carrier thermalization, the electron temperature increase (ΔT ) is linearly proportional to the Gaussian broadening factor σ, providing quantitative real-time tracking of the relaxation of the electron temperature. Measurements reveal an electron cooling time for 50 nm thick polycrystalline nickel films of 640 ± 80 fs. With hot thermalized carriers, the spectral red shift exhibits a power-law relationship with the change in electron temperature of ω s ∝ ΔT 1.5 . Rapid electron thermalization via carrier-carrier scattering accompanies and follows the nominal 4-fs photoexcitation pulse until the carriers reach a quasithermal equilibrium. Entwined with a <6 fs instrument response function, carrier thermalization times ranging from 34 fs to 13 fs are estimated from experimental data acquired at different pump fluences and it is observed that the electron thermalization time decreases with increasing pump fluence. Here, the study provides an initial example of measuring electron temperature and thermalization in metals in real time with XUV light, and it lays a foundation for further investigation of photoinduced phase transitions and carrier transport in metals with core-level absorption spectroscopy.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Transient Liquid Phase Bonding of AlN to AlSiC for Durable Power Electronic Packages

Conventional power electronic modules employ a direct bonded copper (DBC) substrate and multiple interface layers to dissipate heat. However, reliability issues arise due to the coefficient of thermal expansion (CTE) mismatch that exists between the metal, ceramic, and semiconductor materials in the conventional module. Significant performance enhancement can be achieved by eliminating the DBC and developing an integrated substrate/cold plate with a low CTE mismatch throughout the package. To address this need, we have demonstrated the ability to directly bond the aluminum nitride (AlN) substrate to an AlSiC heat sink through transient liquid phase bonding using a Cu-Al binary system. Fabricated samples are found to have good interfacial adhesion. The novel bond material exhibits properties analogous to AlSiC and is analyzed for thermal, mechanical, and metallographic properties. The novel structure demonstrated in this work will enable smaller, lighter, and more reliable power modules, when compared to traditional configurations.

42 ENGINEERING↗

Limitation of Transient Recovery Voltage When Using Shunt Reactors in 110 – 220 kV Networks

In design practice there often arises the problem of assessing the feasibility of installing shunt reactors (SR) when observing conditions of the occurrence of admissible transient recovery voltages at circuit breaker contacts during switching action. A simplified design methodology for this purpose is proposed for calculating the defining parameters of the SR connection circuit, making it possible to define the feasibility of its use in the analyzed circuit.

42 ENGINEERING↗

Evaluation of measuring thermal conductivity of isotropic and anisotropic thermally insulating materials by transient plane source (Hot Disk) technique

The transient plane source (TPS) technique, also referred as the Hot Disk method, has been widely used due to its ability to measure the thermal properties of an extensive range of materials (solids, liquids, and powder). Recently, it has been recognized that typical Hot Disk sensors can influence TPS results of thermally insulating materials and lead to an overestimation of thermal conductivity. Although improvements have been proposed, they have not yet been implemented in the commercial TPS, leaving researchers with non-standardized modifications or options provided by a commercial Hot Disk apparatus. An empirical study of thermally insulating materials such as extruded polystyrene (XPS) and aerogel blanket is conducted in order to address the factors that affect the reliability of thermal conductivity k obtained using the commercial TPS apparatus. Sensor size, input power, duration of the measurements, applied pressure, and, in the case of anisotropic materials, heat capacity are investigated, and the results are compared with those using a Heat Flow Meter apparatus. The effect of sensor size on the k value is ascribed to heat loss through connecting leads and is more pronounced in smaller sensors and in materials with lower k values . In the case of XPS and aerogel, the effect becomes minimal for sensors with a radius r ≥ 6.4 mm. The low input power yields a high scattering of the results and should be avoided. Applied contact pressure and the tested region of the specimen play an important role in experiments with low-density fibrous materials due to the large percentage of heat being transferred by radiation and the heterogeneous nature of the samples, respectively. Additionally, the sensitivity of anisotropic measurements to the value of the material’s volumetric heat capacity ( ρC p ) is shown, emphasizing the need for the precise determination.

thermal conductivity↗

Thermal Conductivity of Thermal Interface Materials Evaluated By a Transient Plane Source Method

The thermal conductivity of thermal interface materials (TIMs) has been investigated using a transient plane source (TPS) method. In thermoelectric generators designed for vehicle waste heat recovery, high thermal conductivity materials are needed for the cold-side interface between a polyamide flexible circuit and an aluminum plate heat exchanger. The conventional heat flow method described by ASTM D5470 is often used to determine thermal contact resistance of an interface with a thin layer of interface material. The apparent thermal conductivity values provided by materials manufacturers are used to calculate heat transfer through the interface. Yet, estimated parameters based on the thermal conductivity of a TIM often do not agree with the actual heat transfer through the interface. Thermal conductivity of a series of 10 commercial TIMs were evaluated by applying a small quantity to an embedded TPS sensor. The 2-mm radius sensor was able to operate under standard bulk material measurement mode and produced consistent thermal conductivity measurements of the interface materials. The TPS method is demonstrated to be effective in ranking the available interface materials by thermal conductivity and to ensure that the material with consistent performance can be selected for the thermoelectric generator applications.