Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Time resolved imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,351 records · Page 75

POLYCYCLIC AROMATIC HYDROCARBON EMISSION IN THE PROPLYD HST10: WHAT IS THE MECHANISM BEHIND PHOTOEVAPORATION?

Proplyds are photodissociation-region-(PDR)-like cometary cocoons around young stars which are thought to originate through photoevaporation of the central protoplanetary disk by external UV radiation from the nearby OB stars. This Letter presents spatially resolved mid-infrared imaging and spectroscopy of the proplyd HST10 obtained with the Very Large Telescope/VISIR instrument. These observations allow us to detect polycyclic aromatic hydrocarbon (PAH) emission in the proplyd PDR and to study the general properties of PAHs in proplyds for the first time. We find that PAHs in HST10 are mostly neutral and at least 50 times less abundant than typical values found for the diffuse interstellar medium or the nearby Orion Bar. With such a low PAH abundance, photoelectric heating is significantly reduced. If this low abundance pertains also to the original disk material, gas heating rates could be too low to efficiently drive photoevaporation unless other processes can be identified. Alternatively, the model behind the formation of proplyds as evaporating disks may have to be revised.

79 ASTRONOMY AND ASTROPHYSICS↗

Analysis of stimulated Raman scattering using diode data at the Pecos experimental platform

In order to increase neutron yield in fusion experiments on the Magnetized Linear Inertial Fusion (MagLIF) platform, it is important to maximize the energy coupled to the fuel during the laser-preheat stage. However, laser-energy coupling is limited by laser—plasma instabilities (LPI). In this regard, the Pecos facility at Sandia National Laboratories uses the Z-beamlet laser to test and study the effects of LPI on MagLIF-relevant targets. In particular, stimulated Raman scattering (SRS) is measured in Pecos by using two photo-diodes and a near-beam imager. The measurements from the photo-diodes are processed using a synthetic spectrum based on a Gaussian model. With this relatively simple model, the mean wavelength and intensity of backscattered light can be deduced. Our measurements show similar trends as those given by time-resolved spectrometer data. Hence, this model provides a simple way to approximate time-resolved spectra for scattered light by SRS.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Time-resolved measurement of electron beam neutralization

An intense relativistic electron beam (IREB) incident on a target generates positive ions by stimulated and thermal desorption of adsorbed gas, and subsequent electron impact ionization. These ions are accelerated upstream by the beam space-charge potential, thereby partially neutralizing the beam. If there is enough neutralization, the repulsive space-charge force can be overcome by the magnetic-pinch force due to the beam current. This so-called ion focusing is responsible for time dependent defocusing of the radiographic source spot. Since a single monolayer of adsorbed gas has a surface density of about 10 15 /cm 2 and is formed in about one second in a one micro-Torr vacuum, there is always enough adsorbed gas to make this a concern in our accelerators. Therefore, time-resolved measurements of the degree of neutralization are valuable for better understanding of this process with an eye to mitigation for improvement of our radiography. Moreover, these measurements would aid quantification of uncertainties due to these effects when using invasive beam diagnostics, such as OTR imaging targets.

43 PARTICLE ACCELERATORS↗

Einstein observations of the Crab nebula pulsar

Einstein Observatory (HEAO 2) high-resolution (approximately 4 sec) images of the Crab nebula which clearly resolve the pulsar from the diffuse X-ray emission are presented. The pulsar contributes 3.9 + or - 0.2 percent of the observed 0.1-4.5 keV flux and shows no evidence (other than the 33 ms pulsations) for variations on time scales up to approximately 2.3 days. The pulsar flux decreases to zero over about one-eighth of the cycle, with the upper limit to point source emission during this interval implying a blackbody surface temperature of less than 2.5 x 10 to the 6th K for the neutron star (10 km assumed radius). The spatial distribution of nebular emission near the pulsar closely resembles that of the optical continuum.

Harnden, F. R., Jr.↗

Intercontinental Bistatic Radar Test Observation of Asteroid 1998 WT24

We describe the first intercontinental planetary radar test performed in Italy observing the near Earth asteroid (NEA) 33342 (1998 WT24) in December 2001 by means of the bistatic configurations Goldstone (California, USA)-Medicina (Italy) and Evpatoria (Ukraine)-Medicina. The experiment goal was to characterize the system for realtime radar follow-up observations of NEAs and artificial orbiting debris, in the framework of a feasibility study which aims at using the Sardinia Radio Telescope, at present under construction, also as a planetary radar facility. We report the preliminary results of the radar observations carried out by the IRA-CNR (Instituto di Radioastronomia - Consiglio Nazionale delle Ricerche) and the OATo (Osservatorio Astronomico di Torino) groups, aimed at exploring the scientific potentials of a new space radar program, using the existing facilities in Italy. The planetary radar technique is uniquely capable of investigating geometry and surface properties of various solar system objects, demonstrating advantages over the optical methods in its high spatial resolution and ability to obtain three-dimensional images. A single radar detection allows to obtain extremely accurate orbital elements, improving the instantaneous positional uncertainties by orders of magnitude with respect to an optically determined orbit. Radar is a powerful means to spatially resolve NEAs by measuring the distribution of the echo power in time delay (range) and Doppler frequency (line-of-sight velocity) with extreme precision in each coordinate, as it provides detailed information about the target physical properties like size, shape, rotation, near-surface bulk density and roughness and internal density distribution. The Medicina 32m antenna had been successfully used for the first time as the receiving part of a bistatic configuration during a test experiment (September 2001) held to check the capabilities of the entire data acquisition system. This test was possible thanks to the collaboration undertaken with the Evpatoria radar station, and consisted in the observation of the ETALON-1 low orbit satellite

Righini, S.↗

Electron–Ion Covariance Reveals Geometry-Resolved Inner-Shell Spectra in CS 2 Photodissociation

The chemical shifts of inner-shell atomic orbitals are highly sensitive to chemical bonding and molecular structure. In evolving systems, however, the spectra of distinct molecular species and geometries overlap, obscuring the underlying chemical dynamics. Here we demonstrate the use of electron–ion covariance analysis to combine the structural sensitivity of Coulomb explosion imaging with inner-shell spectroscopy, yielding geometry-specific spectra of transient and product species. We apply this approach to the excited state dynamics of CS 2 probed by ionization above the S 2p edge. Electron–ion covariance with time- and momentum-selected S + and S 2+ ions isolates distinct S 2p photoelectron spectra for ground-state CS 2 , bent photoexcited CS 2 , the CS photoproduct, and bare atomic sulfur ─ species whose spectra overlap strongly in the channel-averaged measurement. Clear chemical shifts are observed in the covariance photoelectron spectrum for each of these species, all of which are consistent with high-level calculations. Here, by extracting the atomic S contribution to the photoelectron spectrum in a finely time-resolved manner we can disentangle this contribution to the overall time-resolved photoelectron spectrum as the photodissociation proceeds. These results demonstrate the promise of electron–ion covariance as a general approach to geometry-resolved inner-shell spectroscopy, opening a route to tracking structural evolution through chemical shifts in complex photoexcited molecules.

Ionization↗

PRIMA: The PRobe Far-Infrared Mission for Astrophysics

PRIMA is a far-infrared observatory concept being developed to address timely and fundamental questions about the growths of galaxies and solar systems and their constituents. It will observe the build-up of heavy elements, dust, stars, and black holes in galaxies and their interrelationships, and trace the masses and water contents of protoplanetary disks to probe the growths of solar systems. The majority of observing time will be devoted to Guest Observer programs to enable the astrophysics community to identify and plan the most critical observations, with focused PI programs to address key science with rapid releases of data to inform community planning. PRIMA will have spectral, hyperspectral imaging, and polarimetric capabilities, enabled now for the first time by extraordinary progress in kinetic inductance detector (KID) array technology over the last two decades. The 2.0-meter telescope will be cooled to < 5 K to take maximum advantage of the KID sensitivities. For observations of atomic fine-structure lines, molecular lines, and solid-state emission and absorption bands, R = 200 spectral coverage will range from approximately 25 µm to 200 µm, with a high-resolution mode across the entire band that will have a spectral resolving power of a few thousand at 100 µm. R ~ 10 moderate-resolution (hyperspectral) imaging will range from 25 to 80 µm for rest-frame, mid- and far-infrared spectral energy distribution measurements to probe dust grain composition and disambiguate star formation and active galactic nuclei in galaxies. Polarimetric observations of large areas of Galactic molecular clouds and the Magellanic Clouds from 80 to ~200 µm will bridge between the large-scale polarimetry of the interstellar medium from cosmic microwave background observatories and protostellar disk-scale interferometric observations to probe magnetic fields at the critical scales at which clouds collapse to form stars. An overview of PRIMA’s basic design and capabilities will be presented. Other posters in this session describe PRIMA science, technology, and instrumentation in greater depth.

Jason Glenn↗

Spacecraft Material Characterization Using Reflectance Spectra Extracted from RGB/IR Color Images

The space environment is detrimental to the exterior of the spacecraft and imposes stringent requirements on spacecraft materials. Space materials are often expected to perform for 15-20 years in the harsh space environment without significant degradation of their optical, electrical, mechanical and thermal properties. Further, as commercial activities increase in the space domain, development of predictive capability for material evolution is critical for agile adaption of novel materials. Therefore, it is very important to understand the effects of the space environments on the spacecraft materials. The Materials on the International Space Station Experiment Flight Facility (MISSE-FF) has flown numerous material samples to investigate the effect of LEO space weather exposure on the performance and durability of materials and devices. We are manifest on the MISSE-16 mission, scheduled to launch in June 2022, to fly fifteen novel and well-characterized materials in the LEO environment for a duration of six months. Changes in spectral reflectivity will be measured in real time throughout the mission with an RGB/IR camera. These time-resolved data will function as a "space-truth" reference for our team's ongoing laboratory-based space weather-material interaction experiments. Correlation of the MISSE-16 data with extensive ground testing of duplicate samples under simulated space weather conditions will enable development of fundamental chemical models for material degradation. This paper discusses preliminary results from the ground test campaign to collect the RGB/IR images for pristine and damaged materials and the development of machine learning algorithms to extract reflectance spectra from the color images.

Jainisha R. Shah↗

Spacecraft Material Characterization Using Reflectance Spectra Extracted from RGB/IR Color Images

The space environment is detrimental to the exterior of the spacecraft and imposes stringent requirements on spacecraft materials. Space materials are often expected to perform for 15-20 years in the harsh space environment without significant degradation of their optical, electrical, mechanical and thermal properties. Further, as commercial activities increase in the space domain, development of predictive capability for material evolution is critical for agile adaption of novel materials. Therefore, it is very important to understand the effects of the space environments on the spacecraft materials. The Materials on the International Space Station Experiment Flight Facility (MISSE-FF) has flown numerous material samples to investigate the effect of LEO space weather exposure on the performance and durability of materials and devices. We are manifest on the MISSE-16 mission, scheduled to launch in June 2022, to fly fifteen novel and well-characterized materials in the LEO environment for a duration of six months. Changes in spectral reflectivity will be measured in real time throughout the mission with an RGB/IR camera. These time-resolved data will function as a "space-truth" reference for our team's ongoing laboratory-based space weather-material interaction experiments. Correlation of the MISSE-16 data with extensive ground testing of duplicate samples under simulated space weather conditions will enable development of fundamental chemical models for material degradation. This paper discusses preliminary results from the ground test campaign to collect the RGB/IR images for pristine and damaged materials and the development of machine learning algorithms to extract reflectance spectra from the color images.

Jainisha R. Shah↗

Time-resolved spectrophotometry of the emission lines in the galactic X-ray source H2252-035

The galactic X-ray source H2252-035 has been the object of a concentrated observational effort, since Griffiths et al. (1980) have identified it with a cataclysmic variable-like spectrum. Since the observed 859 s periodicity corresponds to the beat frequency between the X-ray and orbital periods, it has been interpreted as related to a reprocessing of the X-ray flux into optical emission in some region of the system which is rotating with the orbital period and heated by beamed X-ray emission from the compact star. In connection with the present investigation, H2252-035 has been observed with a 120 inch (3 m) telescope and image dissector scanner on 1980 September 9/10 and on 1981 September 20/21. At a time resolution of approximately 2 minutes, four bright emission lines showed short time-scale flickering and a pronounced orbital period variation in phase with the continuum modulation. A two-component model for the line emission region is proposed.

Clarke, J. T.↗

Melt front propagation in dielectrics upon femtosecond laser irradiation: Formation dynamics of a heat-affected layer

Several studies in dielectrics have reported the presence of a thin heat-affected layer underneath the ablation crater produced by femtosecond laser irradiation. In this work, we present a time-resolved microscopy technique that is capable of monitoring the formation dynamics of this layer and apply it to the study of a phosphate glass exposed to single pulses below the ablation threshold. A few nanoseconds after laser excitation, a melt front interface can be detected, which propagates into the bulk, gradually slowing down its speed. By means of image analysis combined with optical modeling, we are able to determine the temporal evolution of the layer thickness and its refractive index. Initially, a strong transient decrease in the refractive index is observed, which partially recovers afterwards. The layer resolidifies after approximately 1 μs after excitation, featuring a maximum thickness of several hundreds of nanometers.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

First lunar occultation results from the 2.4 m Thai national telescope equipped with ULTRASPEC

The recently inaugurated 2.4 m Thai National Telescope (TNT) is equipped with, among other instruments, the ULTRASPEC low-noise, frame-transfer EMCCD camera. At the end of its first official observing season, we report on the use of this facility to record high time resolution imaging using small detector subarrays with a sampling as fast as several 10{sup 2} Hz. In particular, we have recorded lunar occultations of several stars that represent the first contribution to this area of research made from Southeast Asia with a telescope of this class. Among the results, we discuss an accurate measurement of α Cnc, which has been reported previously as a suspected close binary. Attempts by several authors to resolve this star have so far met with a lack of unambiguous confirmation. With our observation we are able to place stringent limits on the projected angular separation (<0.''003) and brightness (Δm > 5) of a putative companion. We also present a measurement of the binary HR 7072, which extends considerably the time coverage available for its yet undetermined orbit. We discuss our precise determination of the flux ratio and projected separation in the context of other available data. We conclude by providing an estimate of the performance of ULTRASPEC at TNT for lunar occultation work. This facility can help to extend the lunar occultation technique in a geographical area where no comparable resources were available until now.

79 ASTRONOMY AND ASTROPHYSICS↗

Impact of coolant temperature on the combustion characteristics and emissions of a stratified-charge direct-injection spark-ignition engine fueled with E30

The direct injection spark ignition (DISI) engine has received considerable attention due to its potential to increase the power density of traditional spark ignition engines while significantly improving fuel economy through lean, unthrottled combustion. However, the market introduction of DISI engines operated in a lean combustion mode is inhibited by their unsatisfactory emissions, especially during cold start conditions that make proper mixture formation more challenging. Ethanol-blended gasoline, now a widely used fuel, makes the cold start of a DISI engine more difficult, leading to higher HC and soot emissions because of the high latent heat of vaporization of ethanol relative to gasoline. This work investigated the impact of coolant temperature on the characteristics of combustion and emissions in a stratified-charge DISI engine fueled with an E30 fuel (i.e. 30% ethanol in gasoline), while the coolant temperature was alternated between four levels (45, 60, 75, and 90 °C) to simulate different conditions throughout the warm-up process. The experiments showed that the coolant temperature affected the post-spark inflammation time, as well as the speed, intensity, and stability of the combustion process in the engine. When the coolant temperature rose, the engine produced more NOX and less CO, PM and HC. In addition, high-speed direct photography was used to obtain crank-angle resolved images of fuel sprays and flames in the cylinder. As the coolant temperature rose, the liquid spray lengths became shorter, reducing the possibility of wall wetting, and reduced irradiance from soot particles also indicated less nonpremixed combustion. The in-cylinder imaging results are consistent with the observed combustion and emission characteristics and shed light on the underlying processes. Finally, some potential solutions to the emissions challenges faced here could be either raising in-cylinder temperatures by using trapped residuals or modifying the injection schedule, for example by increasing the number of injections or to inject later in the cycle into a higher-density environment.

42 ENGINEERING↗

Ultrafast infrared nano-imaging of far-from-equilibrium carrier and vibrational dynamics

Ultrafast infrared nano-imaging has demonstrated access to ultrafast carrier dynamics on the nanoscale in semiconductor, correlated-electron, or polaritonic materials. However, mostly limited to short-lived transient states, the contrast obtained has remained insufficient to probe important long-lived excitations, which arise from many-body interactions induced by strong perturbation among carriers, lattice phonons, or molecular vibrations. Here, we demonstrate ultrafast infrared nano-imaging based on excitation modulation and sideband detection to characterize electron and vibration dynamics with nano- to micro-second lifetimes. As an exemplary application to quantum materials, in phase-resolved ultrafast nano-imaging of the photoinduced insulator-to-metal transition in vanadium dioxide, a distinct transient nano-domain behavior is quantified. In another application to lead halide perovskites, transient vibrational nano-FTIR spatially resolves the excited-state polaron-cation coupling underlying the photovoltaic response. These examples show how heterodyne pump-probe nano-spectroscopy with low-repetition excitation extends ultrafast infrared nano-imaging to probe elementary processes in quantum and molecular materials in space and time.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Lorentz electron ptychography for imaging magnetic textures beyond the diffraction limit

Nanoscale spin textures, especially magnetic skyrmions, have attracted intense interest as candidate high-density and power-efficient information carriers for spintronic devices. Facilitating a deeper understanding of sub-100 nm to atomic-scale spin textures requires more advanced magnetic imaging techniques. Here, we demonstrate a Lorentz electron ptychography (LEP) method which can enable high-resolution, high-sensitivity magnetic field imaging for widely-available electron microscopes. The resolution of LEP is not limited by the usual diffraction limit of the lens optics, but instead is determined by the maximum scattering angle at which a statistically meaningful dose can still be recorded – this can be an improvement of up to 2 to 6 times depending on the allowable dose. Using FeGe as a model system, we realize a more accurate magnetic field measurement of skyrmions with an improved spatial resolution and sensitivity by also correcting the probe damping effects from the imaging optics via LEP. This allows us to directly resolve subtle internal structures of magnetic skyrmions near the skyrmion cores, boundaries, and dislocations in an FeGe single crystal. Our study establishes a quantitative, high-resolution magnetic microscopy technique that can reveal the nanoscale spin textures, especially magnetization discontinuities and topological defects in nanomagnets. In conclusion, the technique’s high dose efficiency should also make it well-suited for the exploration of magnetic textures in electron radiation-sensitive materials such as organic or molecular magnets.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Compact x-ray microradiograph for in situ imaging of solidification processes: Bringing in situ x-ray micro-imaging from the synchrotron to the laboratory

A laboratory based high resolution x-ray radiograph was developed for the investigation of solidification dynamics in alloys. It is based on a low-power microfocus x-ray tube and is potentially appropriate for x-ray diagnostics in space. The x-ray microscope offers a high spatial resolution down to approximately 5 {mu}m. Dynamic processes can be resolved with a frequency of up to 6 Hz. In reference experiments, the setup was optimized to yield a high contrast for AlCu-alloys. With samples of about 150 {mu}m thickness, high quality image sequences of the solidification process were obtained with high resolution in time and space.

36 MATERIALS SCIENCE↗

THE VELA PULSAR AND ITS LIKELY COUNTER-JET IN THE K{sub s} BAND

We report the first high spatial resolution near-infrared (near-IR) imaging of the Vela pulsar in the K{sub s} band obtained with the new adaptive optics system recently mounted on the Gemini-South telescope. For the first time, we have firmly detected the pulsar in this band with K{sub s} ≈ 21.8 mag, and have resolved in detail an extended feature barely detected previously in the immediate vicinity of the pulsar in the J{sub s}H bands. The pulsar K{sub s} flux is fully consistent with the extension of the flat optical spectrum of the pulsar toward the IR and does not confirm the strong IR flux excess in the pulsar emission suggested earlier by the low spatial resolution data. The extended feature is about two times brighter than the pulsar and is likely associated with its X-ray counter-jet. It extends ∼2'' southward of the pulsar along the X-ray counter-jet and shows knot-like structures and a red spectrum.

79 ASTRONOMY AND ASTROPHYSICS↗

WE-AB-201-00: Treatment Planning System Commissioning and QA

Treatment planning systems (TPS) are a cornerstone of modern radiation therapy. Errors in their commissioning or use can have a devastating impact on many patients. To support safe and high quality care, medical physicists must conduct efficient and proper commissioning, good clinical integration, and ongoing quality assurance (QA) of the TPS. AAPM Task Group 53 and related publications have served as seminal benchmarks for TPS commissioning and QA over the past two decades. Over the same time, continuing innovations have made the TPS even more complex and more central to the clinical process. Medical goals are now expressed in terms of the dose and margins around organs and tissues that are delineated from multiple imaging modalities (CT, MR and PET); and even temporally resolved (i.e., 4D) imaging. This information is passed on to optimization algorithms to establish accelerator movements that are programmed directly for IMRT, VMAT and stereotactic treatments. These advances have made commissioning and QA of the TPS much more challenging. This education session reviews up-to-date experience and guidance on this subject; including the recently published AAPM Medical Physics Practice Guideline (MPPG) #5 “Commissioning and QA of Treatment Planning Dose Calculations: Megavoltage Photon and Electron Beams”. Treatment Planning System Commissioning and QA: Challenges and Opportunities (Greg Salomons) This session will provide some key background and review publications describing prominent incidents relating to TPS commissioning and QA. Traditional approaches have been hardware and feature oriented. They aim to establish a functional configuration and establish specifications for regular testing of features (like dose calculation) to assure stable operation and detect failures. With the advent of more complex systems, more patient-specific testing has also been adopted. A number of actual TPS defects will be presented along with heuristics for identifying similar defects in the future. Finally, the Gamma test has become a popular metric for reporting TPS Commissioning and QA results. It simplifies complex testing into a numerical index, but noisy data and casual application can make it misleading. A brief review of the issues around the use of the Gamma test will be presented. TPS commissioning and QA: A process orientation and application of control charts (Michael Sharpe) A framework for commissioning a treatment planning system will be presented, focusing on preparations, practical aspects of configuration, priorities, specifications, and establishing performance. The complexity of the modern TPS make modular testing of features inadequate, and modern QA tools can provide “too much information” about the performance of techniques like IMRT and VMAT. We have adopted a process orientation and quality tools, like control charts, for ongoing TPS QA and assessment of patient-specific tests. The trending nature of these tools reveals the overall performance of the TPS system, and quantifies the variations that arise from individual plans, discrete calculations, and experimentation based on discrete measurements. Examples demonstrating application of these tools to TPS QA will be presented. TPS commissioning and QA: Incorporating the entire planning process (Sasa Mutic) The TPS and its features do not perform in isolation. Instead, the features and modules are key components in a complex process that begins with CT Simulation and extends to treatment delivery, along with image guidance and verification. Most importantly, the TPS is used by people working in a multi-disciplinary environment. It is very difficult to predict the outcomes of human interactions with software. Therefore, an interdisciplinary approach to training, commissioning and QA will be presented, along with an approach to the physics chart check and end-to-end testing as a tool for TPS QA. The role of standardization and automation in QA will also be discussed. The recommendations of MPPG #5 and practical implementation strategies (Jennifer Smilowitz) The recently published recommendations from Task Group No. 244, Medical Physics Practice Guideline on Commissioning and QA of Treatment Planning Dose Calculations: Megavoltage Photon and Electron Beams will be presented. The recommendations focus on the validation of commissioning data and dose calculations. Tolerance values for non-IMRT beam configurations are summarized based on established criteria and data collected by the IROC. More stringent evaluation criteria for IMRT dose calculations are suggested to test the limitations of the TPS dose algorithms for advanced delivery conditions. The MPPG encourages users to create a suite of validation tests for dose calculation for various conditions for static photon beams, heterogeneities, IMRT/VMAT and electron beams. This test suite is intended to be used for subsequent testing, including TPS software upgrades. In the past, the recommendations of some reports have not been widely implemented due to practical limitations. Implementation strategies, tools and processes developed by multiple centers for efficient and “do-able” MPPG # 5 testing will be presented, as well as a discussion on the overall validation experience. Learning Objectives: Identify some of the key documents relevant for TPS commissioning and QA Understand strategies for testing TPS software Gain a practical knowledge of the Gamma test criteria Increase familiarity with the process of commissioning a TPS Learn about the use of Control Charts for TPS QA Review the role of the TPS in the overall planning process Increase awareness of the link between TPS QA and chart checking Gain an increased appreciation for the importance of interdisciplinary communication Understand the new recommendations from MPPG #5 on TPS Dose Algorithm Commissioning and QC/QA Learn practical implementation processes and tools for MPPG #5 validation recommendations.

60 APPLIED LIFE SCIENCES↗