Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Target tracking”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,351 records · Page 75

Implementation of Material and Geometry Criticality Search in RMC Code

RMC is a continuous-energy Reactor Monte Carlo neutron and photon transport code being developed by Department of Engineering Physics at Tsinghua University, Beijing. For the use of simulation of reactor control or design of reactor with unknown material and geometry parameters, an accurate and efficient method of eigenvalue search is implemented in RMC code. The eigenvalue search focuses on two types of parameters. One is nuclide atom density, called material search, which includes the fuel density, enrichment or boron concentration. Perturbation theory of Monte Carlo Code, like differential operator method and adjoint-weighted perturbation method has been widely researched in sensitivity and uncertainty study. For material search, the perturbation algorithm needs to coupled with flexible material control block and optimized strategy. The other type of parameter is surface position, called geometry search, which includes fuel rod diameter, pitch and control rod position. MC21 iterated on surface position based on bisection method or regula-falsi method, and directly recalculated k-eff until it converged to target error interval. In this paper, the differential operator method, improved Newton-Raphson method is introduced. Based on these methods, the global material search is implemented. Then based on material search and finite method, global geometry search is implement. Finally, fuel enrichment, boron concentration and control rod position in normal PWR assembly are searched. The results show that RMC can search material and geometry parameters accurately and efficiently. In this paper, global eigenvalue search of material and geometry parameters have been implemented in RMC code. They are based on the differential operator method in Monte Carlo perturbation theory. The differential operator method samples δk/δρ{sub r}, δ{sup 2}k/δρ{sub r}{sup 2} along with k-eff estimator. Therefore it won't take up too much additional computational resource. For homogeneous material search, fission source effect has little effect of accuracy and can be ignored. The results of fuel enrichment and boron concentration searches in assembly show that improved Newton-Raphson method can iterate efficiently until k-eff is in the error interval. Based on material search and finite difference formula, the geometry parameter, like control rod axial position, can iterate until k-eff is in the error interval. However, the tiny perturbed region may not contain enough tracks to simulate. Besides, the large number density's relative change up to -1 may cause underestimation of Δk-eff, and then slope of k-x curve. This will cause non-convergence for Newton- Raphson method. (authors)

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Comprehensive characterization of extracellular vesicles produced by environmental (Neff) and clinical (T4) strains of Acanthamoeba castellanii

We conducted a comprehensive comparative analysis of extracellular vesicles (EVs) from two Acanthamoeba castellanii strains, Neff (environmental) and T4 (clinical). Morphological analysis via transmission electron microscopy revealed slightly larger Neff EVs (average = 194.5 nm) compared to more polydisperse T4 EVs (average = 168.4 nm). Nanoparticle tracking analysis (NTA) and dynamic light scattering validated these differences. Proteomic analysis of the EVs identified 1,352 proteins, with 1,107 common, 161 exclusive in Neff, and 84 exclusively in T4 EVs. Gene ontology and Kyoto Encyclopedia of Genes and Genomes (KEGG) mapping revealed distinct molecular functions and biological processes and notably, the T4 EVs enrichment in serine proteases, aligned with its pathogenicity. Lipidomic analysis revealed a prevalence of unsaturated lipid species in Neff EVs, particularly triacylglycerols, phosphatidylethanolamines (PEs), and phosphatidylserine, while T4 EVs were enriched in diacylglycerols and diacylglyceryl trimethylhomoserine, phosphatidylcholine and less unsaturated PEs, suggesting differences in lipid metabolism and membrane permeability. Metabolomic analysis indicated Neff EVs enrichment in glycerolipid metabolism, glycolysis, and nucleotide synthesis, while T4 EVs, methionine metabolism. Furthermore, RNA-seq of EVs revealed differential transcript between the strains, with Neff EVs enriched in transcripts related to gluconeogenesis and translation, suggesting gene regulation and metabolic shift, while in the T4 EVs transcripts were associated with signal transduction and protein kinase activity, indicating rapid responses to environmental changes. In this novel study, data integration highlighted the differences in enzyme profiles, metabolic processes, and potential origins of EVs in the two strains shedding light on the diversity and complexity of A. castellanii EVs and having implications for understanding host-pathogen interactions and developing targeted interventions for Acanthamoeba-related diseases.

59 BASIC BIOLOGICAL SCIENCES↗

A robust real-time surface reconstruction method on point clouds captured from a 3D surface photogrammetry system

Purpose: To develop a robust and real-time surface reconstruction method on point clouds captured from a 3D surface photogrammetry system. Methods: The authors have developed a robust and fast surface reconstruction method on point clouds acquired by the photogrammetry system, without explicitly solving the partial differential equation required by a typical variational approach. Taking advantage of the overcomplete nature of the acquired point clouds, their method solves and propagates a sparse linear relationship from the point cloud manifold to the surface manifold, assuming both manifolds share similar local geometry. With relatively consistent point cloud acquisitions, the authors propose a sparse regression (SR) model to directly approximate the target point cloud as a sparse linear combination from the training set, assuming that the point correspondences built by the iterative closest point (ICP) is reasonably accurate and have residual errors following a Gaussian distribution. To accommodate changing noise levels and/or presence of inconsistent occlusions during the acquisition, the authors further propose a modified sparse regression (MSR) model to model the potentially large and sparse error built by ICP with a Laplacian prior. The authors evaluated the proposed method on both clinical point clouds acquired under consistent acquisition conditions and on point clouds with inconsistent occlusions. The authors quantitatively evaluated the reconstruction performance with respect to root-mean-squared-error, by comparing its reconstruction results against that from the variational method. Results: On clinical point clouds, both the SR and MSR models have achieved sub-millimeter reconstruction accuracy and reduced the reconstruction time by two orders of magnitude to a subsecond reconstruction time. On point clouds with inconsistent occlusions, the MSR model has demonstrated its advantage in achieving consistent and robust performance despite the introduced occlusions. Conclusions: The authors have developed a fast and robust surface reconstruction method on point clouds captured from a 3D surface photogrammetry system, with demonstrated sub-millimeter reconstruction accuracy and subsecond reconstruction time. It is suitable for real-time motion tracking in radiotherapy, with clear surface structures for better quantifications.

60 APPLIED LIFE SCIENCES↗

VMAT QA: Measurement-guided 4D dose reconstruction on a patient

Purpose: To develop and validate a volume-modulated arc therapy (VMAT) quality assurance (QA) tool that takes as input a time-resolved, low-density ({approx}10 mm) cylindrical surface dose map from a commercial helical diode array, and outputs a high density, volumetric, time-resolved dose matrix on an arbitrary patient dataset. This first validation study is limited to a homogeneous 'patient.'Methods: A VMAT treatment is delivered to a diode array phantom (ARCCHECK, Sun Nuclear Corp., Melbourne, FL). 3DVH software (Sun Nuclear) derives the high-density volumetric dose using measurement-guided dose reconstruction (MGDR). MGDR cylindrical phantom results are then used to perturb the three-dimensional (3D) treatment planning dose on the patient dataset, producing a semiempirical volumetric dose grid. Four-dimensional (4D) dose reconstruction on the patient is also possible by morphing individual sub-beam doses instead of the composite. For conventional (3D) dose comparison two methods were developed, using the four plans (Multi-Target, C-shape, Mock Prostate, and Head and Neck), including their structures and objectives, from the AAPM TG-119 report. First, 3DVH and treatment planning system (TPS) cumulative point doses were compared to ion chamber in a cube water-equivalent phantom ('patient'). The shape of the phantom is different from the ARCCHECK and furthermore the targets were placed asymmetrically. Second, coronal and sagittal absolute film dose distributions in the cube were compared with 3DVH and TPS. For time-resolved (4D) comparisons, three tests were performed. First, volumetric dose differences were calculated between the 3D MGDR and cumulative time-resolved patient (4D MGDR) dose at the end of delivery, where they ideally should be identical. Second, time-resolved (10 Hz sampling rate) ion chamber doses were compared to cumulative point dose vs time curves from 4D MGDR. Finally, accelerator output was varied to assess the linearity of the 4D MGDR with global fluence change. Results: Across four TG-119 plans, the average PTV point dose difference in the cube between 3DVH and ion chamber is 0.1 {+-} 1.0%. Average film vs TPS {gamma}-analysis passing rates are 83.0%, 91.1%, and 98.4% for 1%/2 mm, 2%/2 mm, and 3%/3 mm threshold combinations, respectively, while average film vs 3DVH {gamma}-analysis passing rates are 88.6%, 96.1%, and 99.5% for the same respective criteria. 4D MGDR was also sufficiently accurate. First, for 99.5% voxels in each case, the doses from 3D and 4D MGDR at the end of delivery agree within 0.5%local dose-error/1 mm distance. Moreover, all failing voxels are confined to the edge of the cylindrical reconstruction volume. Second, dose vs time curves track between the ion chamber and 4D MGDR within 1%. Finally, 4D MGDR dose changes linearly with the accelerator output: the difference between cumulative ion chamber and MGDR dose changed by no more than 1% (randomly) with the output variation range of 10%. Conclusions: Even for a well-commissioned TPS, comparison metrics show better agreement on average to MGDR than to TPS on the arbitrary-shaped measurable 'patient.' The method requires no more accelerator time than standard QA, while producing more clinically relevant information. Validation in a heterogeneous thoracic phantom is under way, as is the ultimate application of 4D MGDR to virtual motion studies.

60 APPLIED LIFE SCIENCES↗

The Significance of the Bystander Effect: Modeling, Experiments, and More Modeling

Non-targeted (bystander) effects of ionizing radiation are caused by intercellular signaling; they include production of DNA damage and alterations in cell fate (i.e. apoptosis, differentiation, senescence or proliferation). Biophysical models capable of quantifying these effects may improve cancer risk estimation at radiation doses below the epidemiological detection threshold. Understanding the spatial patterns of bystander responses is important, because it provides estimates of how many bystander cells are affected per irradiated cell. In a first approach to modeling of bystander spatial effects in a three-dimensional artificial tissue, we assumed the following: (1) The bystander phenomenon results from signaling molecules (S) that rapidly propagate from irradiated cells and decrease in concentration (exponentially in the case of planar symmetry) as distance increases. (2) These signals can convert cells to a long-lived epigenetically activated state, e.g. a state of oxidative stress; cells in this state are more prone to DNA damage and behavior alterations than normal and therefore exhibit an increased response (R) for many end points (e.g. apoptosis, differentiation, micronucleation). These assumptions were implemented by a mathematical formalism and computational algorithms. The model adequately described data on bystander responses in the 3D system using a small number of adjustable parameters. Mathematical models of radiation carcinogenesis are important for understanding mechanisms and for interpreting or extrapolating risk. There are two classes of such models: (1) long-term formalisms that track pre-malignant cell numbers throughout an entire lifetime but treat initial radiation dose-response simplistically and (2) short-term formalisms that provide a detailed initial dose-response even for complicated radiation protocols, but address its modulation during the subsequent cancer latency period only indirectly. We argue that integrating short- and long-term models is needed. As an example of this novel approach, we integrated a stochastic short-term initiation/inactivation/repopulation model with a deterministic two-stage long-term model. Within this new formalism, the following assumptions are implemented: radiation initiates, promotes, or kills pre-malignant cells; a pre-malignant cell generates a clone, which, if it survives, quickly reaches a size limitation; the clone subsequently grows more slowly and can eventually generate a malignant cell; the carcinogenic potential of pre-malignant cells decreases with age. The effectiveness of high-LET radiation per unit dose increases as dose rate decreases. This “inverse dose rate effect” is seen in radon-induced lung carcinogenesis. We suggest a biologically-motivated mechanism based on radiation-induced direct and bystander-effect-related risks: During radon exposure, only a fraction of cells are traversed by alpha particles. These irradiated cells have an increased probability of being initiated into a pre-malignant state. They release signals, which convert some nearby unirradiated cells to an activated state. When already pre-malignant cells are activated, their proliferation (promotion) rate increases. If a radiation dose is sufficient to activate most susceptible cells, protracting the exposure does not substantially decrease the number of activated cells, but prolongs the activated state during which pre-malignant cell proliferation is accelerated. This mechanism is implemented in a low-dose-rate extension of our carcinogenesis model, which integrates both short- and long-term modeling approaches, and was applied to radiotherapy-induced second cancer risk estimation. Model predictions adequately describe the data on radon-induced lung carcinogenesis in humans and rats, using few adjustable parameters. Conclusions about the relative importance of promotion vs. initiation for radon carcinogenesis are similar to those reported with the two-stage clonal expansion model, but a mechanistic explanation for promotion is provided.

59 BASIC BIOLOGICAL SCIENCES↗

Development of a Framework for Data Integration, Assimilation, and Learning for Geological Carbon Sequestration (DIAL-GCS) (Final Report)

This project aimed to develop and demonstrate a Data Integration, Assimilation, and Learning framework for geologic carbon sequestration projects (DIAL-GCS). DIAL-GCS is an intelligence monitoring system (IMS) for automating GCS closed-loop management by leveraging recent developments in machine learning technologies, complex event processing (CEP), and reduced-order modeling. The safe and efficient operation of GCS repositories requires integrated monitoring to track the injected CO¬2 as it moves within a storage reservoir. GCS projects are data intensive, as a result of proliferation of digital instrumentation and smart-sensing technologies. GCS projects are also resource intensive, often requiring multidisciplinary teams performing different monitoring, verification, accounting (MVA) tasks throughout the lifecycle of a project to ensure secure containment of injected CO2. The success of GCS thus depends in a large part on our ability to access, assimilate, and analyze heterogeneous data and information sources in a timely manner. This project included a number of meaningful and necessary tasks to transform the human domain knowledge into machine-interpretable rules for automating knowledge extraction and discovery in GCS. The specific technical objectives of the proposed DIAL-GCS project were to develop an ontology-driven GCS data management module for storing, querying, and exchanging GCS data (both historic and live sensor data) from multiple sources and in heterogeneous formats. Incorporate a CEP engine for detecting abnormal situations by seamlessly combining expert knowledge, rule-based reasoning, and machine learning. Enable uncertainty quantification and predictive analytics using a combination of coupled-process modeling, AI/ML methods, and reduced-order modeling, and integrate and demonstrate the system’s capabilities with both real and simulated data. As far as we know, this is one of the first projects aimed to develop intelligent monitoring systems (IMS) targeting the GCS. Under this project, the team had developed a large number of web applications and scientific algorithms that contribute the main theme of intelligent monitoring. The team has published more than a dozen peer reviewed papers and disseminated the research results at multiple technical meetings.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Tracking DO 2 with Compensatory Reserve during Whole Blood Resuscitation in Baboons

Background Hemorrhagic shock can be mitigated by timely and accurate resuscitation designed to restore adequate delivery of oxygen (DO 2 ) by increasing cardiac output (CO). However, standard care of using systolic blood pressure (SBP) as a guide for resuscitation has proven ineffective and can be associated with increased morbidity. We have developed a novel vital sign called the compensatory reserve (CRM) generated from analysis of arterial pulse waveform feature changes that has been validated in experimental and clinical models of hemorrhage. We tested the hypothesis that thresholds of DO 2 could be accurately defined by CRM while avoiding over resuscitation during whole blood resuscitation following a 25% hemorrhage in non‐human primates. Methods To accomplish this, adult male baboons (n=12) were exposed to a progressive controlled hemorrhage that resulted in an average (± SD) maximal reduction of 601 ± 18 ml of their estimated circulating blood volume of 1,262 ± 64 ml based on body weight. Values of DO 2 were calculated as the product of CO times O 2 carrying capacity of hemoglobin (i.e., Hb content × 1.34). Results Average (± SD) CRM increased from 6 ± 5 % at the end of hemorrhage to 70 ± 7 % at the end of resuscitation. DO 2 of 12.1, 10.3, and 7.0 ml O 2 ·kg −1 ·min −1 were calculated at 0% (baseline), 12.5% and 25% blood loss. By linear regression, CRM values of 6% (decompensation), 35%, and 68% corresponded to calculated DO 2 values of 6.0, 9.2, and 12.1 ml O 2 ·kg −1 ·min −1 during resuscitation. As such, return of CRM to baseline during resuscitation with only ~ 450 ml provided adequate DO 2 (12.5 ml O 2 ·kg −1 ·min −1 ) while total blood volume replacement (~600 ml) resulted in over resuscitation as indicated by an average increase in SBP (+17 mmHg) and CO (+0.1 L/min) over baseline values. Conclusion Consistent with our hypothesis, thresholds of DO 2 were associated with specific CRM values. A target resuscitation CRM value of 70% minimized the requirement for whole blood, while avoiding over resuscitation. Furthermore, CRM at 0% provided a noninvasive metric for determining critical DO 2 at approximately 5.4 ml O 2 ·kg −1 ·min −1 . Support or Funding Information This research was supported in part by appointment of Ms. Koons to the Postgraduate Research Fellowship Program at the US Army Institute of Surgical Research administered by the Oak Ridge Institute for Science and Education through an interagency agreement between the US Department of Energy and USAMRMC. Study funding was provided by a grant from the US Army Combat Casualty Care Research Program (D‐009‐2014‐USAISR). Linearregression of the relationship between DO 2 and compensatory reserve during whole blood resuscitation in baboons. Data are expressed as mean ± SE. image Linearregression of the relationship between DO 2 and compensatory reserve during whole blood resuscitation in baboons. Data are expressed as mean ± SE. This abstract is from the Experimental Biology 2019 Meeting. There is no full text article associated with this abstract published in The FASEB Journal .

Koons, Natalie Jane↗

WE-AB-303-06: Combining DAO with MV + KV Optimization to Improve Skin Dose Sparing with Real-Time Fluoroscopy

Purpose: Real-time fluoroscopy may allow for improved patient positioning and tumor tracking, particularly in the treatment of lung tumors. In order to mitigate the effects of the imaging dose, previous studies have demonstrated the effect of including both imaging dose and imaging constraints into the inverse treatment planning object function. That method of combined MV+kV optimization may Result in plans with treatment beams chosen to allow for more gentle imaging beam-on times. Direct-aperture optimization (DAO) is also known to produce treatment plans with fluence maps more conducive to lower beam-on times. Therefore, in this work we demonstrate the feasibility of a combination of DAO and MV+kV optimization for further optimized real-time kV imaging. Methods: Therapeutic and imaging beams were modeled in the EGSnrc Monte Carlo environment, and applied to a patient model for a previously treated lung patient to provide dose influence matrices from DOSXYZnrc. An MV + kV IMRT DAO treatment planning system was developed to compare DAO treatment plans with and without MV+kV optimization. The objective function was optimized using simulated annealing. In order to allow for comparisons between different cases of the stochastically optimized plans, the optimization was repeated twenty times. Results: Across twenty optimizations, combined MV+kV IMRT resulted in an average of 12.8% reduction in peak skin dose. Both non-optimized and MV+kV optimized imaging beams delivered, on average, mean dose of approximately 1 cGy per fraction to the target, with peak doses to target of approximately 6 cGy per fraction. Conclusion: When using DAO, MV+kV optimization is shown to Result in improvements to plan quality in terms of skin dose, when compared to the case of MV optimization with non-optimized kV imaging. The combination of DAO and MV+kV optimization may allow for real-time imaging without excessive imaging dose. Financial support for the work has been provided in part by NIH Grant T32 EB002103, ACS RSG-13-313-01-CCE, and NIH S10 RR021039 and P30 CA14599 grants. The contents of this submission do not necessarily represent the official views of any of the supporting organizations.

60 APPLIED LIFE SCIENCES↗

Molecular characterization of organic matter mobilized from Bangladeshi aquifer sediment: tracking carbon compositional change during microbial utilization

Bioavailable organic carbon in aquifer recharge waters and sediments can fuel microbial reactions with implications for groundwater quality. A previous incubation experiment showed that sedimentary organic carbon (SOC) mobilized off sandy sediment collected from an arsenic-contaminated and methanogenic aquifer in Bangladesh was bioavailable; it was transformed into methane. We used high-resolution mass spectrometry to molecularly characterize this mobilized SOC, reference its composition against dissolved organic carbon (DOC) in surface recharge water, track compositional changes during incubation, and advance understanding of microbial processing of organic carbon in anaerobic environments. Organic carbon mobilized off aquifer sediment was more diverse, proportionately larger, more aromatic, and more oxidized than DOC in surface recharge. Mobilized SOC was predominately composed of terrestrially derived organic matter and had characteristics signifying that it evaded microbial processing within the aquifer. Approximately 50?% of identified compounds in mobilized SOC and in DOC from surface recharge water contained sulfur. During incubation, after mobilized SOC was converted into methane, new organosulfur compounds with high S-to-C ratios and a high nominal oxidation state of carbon (NOSC) were detected. We reason that these detected compounds formed abiotically following microbial reduction of sulfate to sulfide, which could have occurred during incubation but was not directly measured or that they were microbially synthesized. Most notably, microbes transformed all carbon types during incubation, including those currently considered thermodynamically unviable for microbes to degrade in anaerobic conditions (i.e., those with a low NOSC). In anaerobic environments, energy yields from redox reactions are small and the amount of energy required to remove electrons from highly reduced carbon substrates during oxidation decreases the thermodynamic favorability of degrading compounds with a low NOSC. While all compound types were eventually degraded during incubation, NOSC and compound size controlled the rates of carbon transformation. Large, more thermodynamically favorable compounds (e.g., aromatics with a high NOSC) were targeted first, while small, less thermodynamically favorable compounds (e.g., alkanes and olefinics with a low NOSC) were used last. These results indicate that in anaerobic conditions, microbial communities are capable of degrading and mineralizing all forms of organic matter, converting larger energy-rich compounds into smaller energy-poor compounds. However, in an open system, where fresh carbon is continually supplied, the slower degradation rate of reduced carbon compounds would enable this portion of the organic carbon pool to build up, explaining the apparent persistence of compounds with a low NOSC in anaerobic environments.

Pracht, Lara↗

Measurement of 3-Flavour Neutrino Oscillation Parameters in the NOvA Experiment

NOvA is a long-baseline neutrino oscillation experiment consisting of two functionally identical tracking calorimeters, a Near and Far Detector, that measure neutrino interactions induced by the Fermi National Accelerator Laboratory’s NuMI beam at baselines of 1 km and 810 km, respectively. The NuMI beam can be configured to produce either a primary ν µ neutrino or $\bar{ν}$ µ anti-neutrino beam. Neutrino oscillations are observed and measured by the analysis of ν µ + $\bar{ν}$ µ disappearance and νe + $\bar{ν}$ e appearance in the beam, comparing the neutrino energy spectra in the Near and Far detectors means that neutrino oscillation parameters sin 2 θ 23 , |Δ$m^2_{32}$|, and δ CP can be constrained. This thesis presents the 2018 NOvA ν µ +$\bar{ν}$ µ disappearance, ν e +$\bar{ν}$ e appearance, and combined analyses using both neutrino and anti-neutrino data, where oscillation fits have been performed, where possible, on an event-by-event basis rather than on a bin-by-bin basis as has conventionally been used in NOvA oscillation analyses. This allows for better precision in applying both neutrino oscillation probabilities and systematic uncertainties. Furthermore, oscillation analyses for the disappearance, appearance, and combined channels are presented using an unbinned likelihood fit and compared with the equivalent binned χ 2 likelihood fit used in the standard analysis. The 14 ktonne detector equivalent beam exposures used for this thesis are 8.85 × 10 20 and 6.91 × 10 20 protons on target for neutrino and antineutrino data respectively, corresponding to 5 years of NOvA data taking. A combined ν µ + $\bar{ν}$ µ disappearance and ν e + $\bar{ν}$ e appearance fit to the Far Detector data, assuming normal mass ordering and using the event-by-event oscillation and unbinned fitting methodologies, produces oscillation parameter constraints of Δ$m^2_{32}$ = (2.50$^{+0.08}_{-0.06}$) × 10 -3 eV 2 , sin 2 θ 23 = 0.59$^{+0.02}_{-0.04}$, and δ CP = 0.72$^{+0.5}_{-0.9}$π.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Design and performance of a 35-ton liquid argon time projection chamber as a prototype for future very large detectors

Liquid argon time projection chamber technology is an attractive choice for large neutrino detectors, as it provides a high-resolution active target and it is expected to be scalable to very large masses. Consequently, it has been chosen as the technology for the first module of the DUNE far detector. However, the fiducial mass required for “far detectors” of the next generation of neutrino oscillation experiments far exceeds what has been demonstrated so far. Scaling to this larger mass, as well as the requirement for underground construction places a number of additional constraints on the design. A prototype 35-ton cryostat was built at Fermi National Acccelerator Laboratory to test the functionality of the components foreseen to be used in a very large far detector. The Phase I run, completed in early 2014, demonstrated that liquid argon could be maintained at sufficient purity in a membrane cryostat. A time projection chamber was installed for the Phase II run, which collected data in February and March of 2016. The Phase II run was a test of the modular anode plane assemblies with wrapped wires, cold readout electronics, and integrated photon detection systems. While the details of the design do not match exactly those chosen for the DUNE far detector, the 35-ton TPC prototype is a demonstration of the functionality of the basic components. Measurements are performed using the Phase II data to extract signal and noise characteristics and to align the detector components. A measurement of the electron lifetime is presented, and a novel technique for measuring a track's position based on pulse properties is described.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Validation of a novel robot-assisted 3DUS system for real-time planning and guidance of breast interstitial HDR brachytherapy

Purpose: In current clinical practice, there is no integrated 3D ultrasound (3DUS) guidance system clinically available for breast brachytherapy. In this study, the authors present a novel robot-assisted 3DUS system for real-time planning and guidance of breast interstitial high dose rate (HDR) brachytherapy treatment. Methods: For this work, a new computer controlled robotic 3DUS system was built to perform a hybrid motion scan, which is a combination of a 6 cm linear translation with a 30° rotation at both ends. The new 3DUS scanner was designed to fit on a modified Kuske assembly, keeping the current template grid configuration but modifying the frame to allow the mounting of the 3DUS system at several positions. A finer grid was also tested. A user interface was developed to perform image reconstruction, semiautomatic segmentation of the surgical bed as well as catheter reconstruction and tracking. A 3D string phantom was used to validate the geometric accuracy of the reconstruction. The volumetric accuracy of the system was validated with phantoms using magnetic resonance imaging (MRI) and computed tomography (CT) images. In order to accurately determine whether 3DUS can effectively replace CT for treatment planning, the authors have compared the 3DUS catheter reconstruction to the one obtained from CT images. In addition, in agarose-based phantoms, an end-to-end procedure was performed by executing six independent complete procedures with both 14 and 16 catheters, and for both standard and finer Kuske grids. Finally, in phantoms, five end-to-end procedures were performed with the final CT planning for the validation of 3DUS preplanning. Results: The 3DUS acquisition time is approximately 10 s. A paired Student t-test showed that there was no statistical significant difference between known and measured values of string separations in each direction. Both MRI and CT volume measurements were not statistically different from 3DUS volume (Student t-test: p > 0.05) and they were significantly correlated to 3DUS measurement (Pearson test: MRI p < 0.05 and CT p < 0.001). The mean angular separation distance between catheter trajectories segmented from 3DUS and CT images was 0.42° ± 0.24°, while the maximum and mean trajectory separations were 0.51 ± 0.19 and 0.37 ± 0.17 mm, respectively. Overall, the new finer grid has performed significantly better in terms of dosimetric indices. The planning target volume dosimetric indices were not found statistically different between 3DUS and CT planning (Student t-test, p > 0.05). Both the skin and the pectoral muscle dosimetric indices were within ABS guidelines. Conclusions: A novel robot-assisted 3DUS system was designed and validated. To their knowledge, this is the first system capable of performing real-time guidance and planning of breast multicatheter HDR brachytherapy treatments. Future investigation will test the feasibility of using the system in the clinic and for permanent breast brachytherapy.

60 APPLIED LIFE SCIENCES↗

What CTV-to-PTV Margins Should Be Applied for Prostate Irradiation? Four-Dimensional Quantitative Assessment Using Model-Based Deformable Image Registration Techniques

Purpose: To quantify adequate anisotropic clinical target volume (CTV)-to-planning target volume (PTV) margins for three different setup strategies used during prostate irradiation: (1) no setup corrections, (2) on-line corrections determined from bony anatomy, and (3) on-line corrections determined from gold markers. Method and Materials: Three radiation oncologists independently delineated the CTV on computed tomography images of 30 prostate cancer patients. Eight repeat scans were acquired to allow simulation of the delivered dose distributions in changing geometry. Different registration approaches were taken to mimic the different setup strategies. A surface model-based deformable image registration system was used to warp the delivered dose distributions back to the dose in the planning computed tomography scan. On the basis of the geometric extent of the underdosed areas, a set of anisotropic margins was derived to ensure a minimal dose to the CTV of 95% for 90% of the patients. Results: Without setup correction, margins of approximately 11 mm for the corpus of the prostate and 15 mm for the seminal vesicles were required. These margins could be reduced to 8 and 13 mm when aligning the patient to the bony anatomy and to 3 and 8 mm aligning the patient to implanted gold markers. A larger margin at the apex was required to account for the significant observer variability and steep dose gradients at this location (11 mm using skin marker registration, 9 mm using bony anatomy registration, and 6 mm using gold marker registration). Conclusions: Novel voxel tracking techniques have enabled us to calculate accumulated dose distributions and design accurate three-dimensional CTV-to-PTV margins for prostate irradiation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

National CO 2 budgets (2015–2020) inferred from atmospheric CO 2 observations in support of the global stocktake

Accurate accounting of emissions and removals of CO 2 is critical for the planning and verification of emission reduction targets in support of the Paris Agreement. Here, we present a pilot dataset of country-specific net carbon exchange (NCE; fossil plus terrestrial ecosystem fluxes) and terrestrial carbon stock changes aimed at informing countries' carbon budgets. These estimates are based on “top-down” NCE outputs from the v10 Orbiting Carbon Observatory (OCO-2) modeling intercomparison project (MIP), wherein an ensemble of inverse modeling groups conducted standardized experiments assimilating OCO-2 column-averaged dry-air mole fraction (X CO 2 ) retrievals (ACOS v10), in situ CO 2 measurements or combinations of these data. The v10 OCO-2 MIP NCE estimates are combined with “bottom-up” estimates of fossil fuel emissions and lateral carbon fluxes to estimate changes in terrestrial carbon stocks, which are impacted by anthropogenic and natural drivers. These flux and stock change estimates are reported annually (2015–2020) as both a global 1° x 1° gridded dataset and a country-level dataset and are available for download from the Committee on Earth Observation Satellites' (CEOS) website. Across the v10 OCO-2 MIP experiments, we obtain increases in the ensemble median terrestrial carbon stocks of 3.29–4.58 Pg CO2 yr -1 (0.90–1.25 Pg C yr -1 ). This is a result of broad increases in terrestrial carbon stocks across the northern extratropics, while the tropics generally have stock losses but with considerable regional variability and differences between v10 OCO-2 MIP experiments. We discuss the state of the science for tracking emissions and removals using top-down methods, including current limitations and future developments towards top-down monitoring and verification systems.

54 ENVIRONMENTAL SCIENCES↗

Searching for Strongly-Interacting Dark Matter with the Heavy Photon Search Experiment

The Heavy Photon Search Experiment (HPS) is a fixed-target experiment at Jefferson Lab’s Hall B, designed to explore a hidden sector (HS) of particles containing dark matter and a new force mediator known as the “heavy photon” (A'). The A' is a massive spin-1 gauge boson associated with a new U (1)D symmetry in the HS that kinetically mixes with the Standard Model () photon with a weak coupling strength parameterized by ¿, with ¿2 ~ 10-2 -10-10. HPS utilizes a high-intensity electron beam on a thin tungsten target to produce heavy photons in the MeV-GeV mass range via “dark bremsstrahlung,” a process analogous to SM bremsstrahlung but suppressed by ¿2. The A' can decay resonantly to SM leptons, allowing HPS to conduct both mass resonance searches for prompt decays (large ¿) and displaced vertex searches for long-lived particles (small ¿). In addition to the minimal A' model, HPS probes more complex extensions such as the QCD-like strongly-interacting massive particles (SIMPs) HS containing “dark” pions (pD) and vector mesons (VD), with pD as dark matter candidates. These particles introduce new thermal dark matter freeze- out scenarios and visible signals through long-lived VD decays to SM leptons, which are accessible to HPS. This analysis conducted a displaced vertex search for VD ¿ e-e+ in the mass range 30 MeV to 124 MeV and ¿ between 10-6 < ¿ < 10-2 using data from the 2016 Engineering Run (10.753 nb-1) at 2.3 GeV. Unlike the minimal A' search, SIMP signal kinematics required new approaches to signal normalization and SM background rejection. The strongest signal evidence was a local p-value of 0.01317 for mVD = 119 MeV, corresponding to a global significance of 0.9s. Although no signal was found, this search excluded a region of the SIMP parameter space at 90 % confidence. This work demonstrates HPS’s competitive capability to probe SIMP sectors within cosmologically significant parameters and introduces a new method for HPS displaced vertex searches using track vertical impact parameter cuts

Spellman, Alic [Univ. of California, Santa Cruz, C↗

Position detection accuracy of a novel linac-mounted intrafractional x-ray imaging system

Purpose: The authors have developed a system that monitors intrafractional target motion perpendicular to the treatment beam with the aid of radioopaque markers by means of separating kV image and megavoltage (MV) treatment field on a single flat-panel detector. Methods: They equipped a research Siemens Artiste linear accelerator (linac) with a 41 x 41 cm{sup 2} a-Si flat-panel detector underneath the treatment head. The in-line geometry allows kV (imaging) and MV (treatment) beams to share closely aligned beam axes. The kV source, usually mounted directly across from the flat-panel imager, was retracted toward the gantry by 13 cm to intentionally misalign kV and MV beams, resulting in a geometric separation of MV treatment field and kV image on the detector. Two consecutive images acquired within 140 ms (the first with MV-only and the second with kV and MV signal) were subtracted to generate a kV-only image. The images were then analyzed ''online'' with an automated threshold-based marker detection algorithm. They employed a 3D and a 4D phantom equipped with either a single radioopaque marker or three Calypso beacons to mimic respiratory motion. Measured room positions were either cross-referenced with a phantom voltage signal (single marker) or the Calypso system. The accuracy of the back-projection (from detected marker positions into room coordinates) was verified by a simulation study. Results: A phantom study has demonstrated that the imaging framework is capable of automatically detecting marker positions and sending this information to the tracking tool at an update rate of 7.14 Hz. The system latency is 86.9 {+-} 1.0 ms for single marker detection in the absence of MV radiation. In the presence of a circular MV field of 5 cm diameter, the latency is 87.1 {+-} 0.9 ms. The total RMS position detection accuracy is 0.20 mm (without MV radiation) and 0.23 mm (with MV). Conclusions: Based on the evaluated motion patterns and MV field size, the positional accuracy and system latency indicate that this system is suitable for real-time adaptive applications.

60 APPLIED LIFE SCIENCES↗

AstroPix4 — a novel HV-CMOS sensor developed for space based experiments

For the proposed space based gamma-ray observatory All-sky Medium-Energy Gamma-ray Observatory eXplorer (AMEGO-X), a silicon tracker based on a novel High Voltage-CMOS (HV-CMOS) sensor called AstroPix, is currently being developed. Preliminary measurements with the first full reticle prototype AstroPix3 show that the power target of 1.5 mW/cm 2 can currently not be reached due to the digital consumption of 3.08 mW/cm 2 , while the analog power consumption of 1.04 mW/cm 2 and a break down voltage of over 350 V look promising. Based on these results, the design changes in AstroPix4, submitted in May 2023, are presented, containing changes to the time stamp generation and readout architecture. A digital power consumption below 0.25 mW/cm 2 is expected by removing the fast 200 MHz clock used to measure the time-over-threshold (ToT) and an LVDS receiver. A maximum resolution of 3.125 ns for time-of-arrival (ToA) and ToT is reached by adding per-pixel Flash-Time-to-Digital Converter (TDCs) controlled by a global delay-locked loop (DLL).

47 OTHER INSTRUMENTATION↗

ν{sub μ} CCπ° reaction in the tracker of the ND280 detector in the T2K experiment

A good knowledge of both inclusive and exclusive neutrino interaction cross sections is one of the key issues for a precise determination of the neutrino oscillation parameters in the T2K experiment. These studies are performed at the near detector (ND280). Its central tracker part equipped with a water target is used, among others, to study the ν{sub μ}CCπ° reaction. At the energies of the T2K neutrino beam its contribution to the total cross section is relatively large, so the reaction is a potential source of the background for the quasi-elastic ν{sub μ}CC reaction. Two different production mechanisms contribute to ν{sub μ}CCπ°: single pion resonance production and Deep Inelastic Scattering (DIS). In addition, Final State Interactions (FSI) have to be considered. Thus, the analysis of the ν{sub μ}CCπ° reaction aims also at a better tuning of the Monte Carlo (MC) models used to describe neutrino interactions in T2K. This paper describes selection criteria leading to the determination of the inclusive and exclusive cross sections for the π° production in the ν{sub μ}CC interactions.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗