Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Target”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,351 records · Page 75

Comparison of effectiveness and energy use of airborne pathogen mitigation measures to meet clean air targets in a prototypical office building

Organizations such as ASHRAE and the Centers for Disease Control and Prevention (CDC) have proposed guidelines for controlling infectious aerosols in buildings, which can be met through measures such as modified operation of the heating, ventilation, and air-conditioning (HVAC) system or incorporating air-cleaning technologies. However, more research is needed to understand the trade-offs between health, energy, and comfort aspects when designing measures for these guidelines. To address this gap, this paper presents an analysis using new models for air-cleaning technologies, including in-duct and in-room germicidal ultraviolet (GUV) systems and portable air cleaners (PACs). These models are incorporated into an existing prototypical office building model and six measures are designed to meet ASHRAE Standard 241 and CDC clean air targets: MERV 13 HVAC filtration, maximum outdoor air supplied to the building, PACs, and in-duct, upper-room, and whole-room GUV. The measures are simulated for an office building in a cool and humid climate compared against a baseline simulation using MERV 8 filtration. The results show that all measures, except for the maximum outdoor air case, can meet the ASHRAE 241 standard without significant impacts on energy or comfort. The HVAC system measures were not able to meet the CDC target with the default system sizing and lead to significant energy increases, while the in-room measures were able to meet the CDC target with small impacts on energy consumption. Finally, this paper consolidates the simulation findings and provides practical guidance for building operators to meet clean air targets while limiting energy and comfort impacts.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Rare, convergent antibodies targeting the stem helix broadly neutralize diverse betacoronaviruses

Humanity has faced three recent outbreaks of novel betacoronaviruses, emphasizing the need to develop approaches that broadly target coronaviruses. Here, we identify 55 monoclonal antibodies from COVID-19 convalescent donors that bind diverse betacoronavirus spike proteins. Most antibodies targeted an S2 epitope that included the K814 residue and were non-neutralizing. However, 11 antibodies targeting the stem helix neutralized betacoronaviruses from different lineages. Eight antibodies in this group, including the six broadest and most potent neutralizers, were encoded by IGHV1-46 and IGKV3-20. Crystal structures of three antibodies of this class at 1.5–1.75-Å resolution revealed a conserved mode of binding. COV89-22 neutralized SARS-CoV-2 variants of concern including Omicron BA.4/5 and limited disease in Syrian hamsters. Collectively, these findings identify a class of IGHV1-46/IGKV3-20 antibodies that broadly neutralize betacoronaviruses by targeting the stem helix but indicate these antibodies constitute a small fraction of the broadly reactive antibody response to betacoronaviruses after SARS-CoV-2 infection.

60 APPLIED LIFE SCIENCES↗

Pathways to Mexico’s climate change mitigation targets: A multi-model analysis

Mexico’s climate policy sets ambitious national greenhouse gas (GHG) emission reduction targets—30% versus a business-as-usual baseline by 2020, 50% versus 2000 by 2050. However, these goals are at odds with recent energy and emission trends in the country. Both energy use and GHG emissions in Mexico have grown substantially over the last two decades. Here, we investigate how Mexico might reverse current trends and reach its mitigation targets by exploring results from energy system and economic models involved in the CLIMACAP-LAMP project. To meet Mexico’s emission reduction targets, all modeling groups agree that decarbonization of electricity is needed, along with changes in the transport sector, either to more efficient vehicles or a combination of more efficient vehicles and lower carbon fuels. These measures reduce GHG emissions as well as emissions of other air pollutants. The models find different energy supply pathways, with some solutions based on renewable energy and others relying on biomass or fossil fuels with carbon capture and storage. The economy-wide costs of deep mitigation could range from 2% to 4% of GDP in 2030, and from 7% to 15% of GDP in 2050. Our results suggest that Mexico has some flexibility in designing deep mitigation strategies, and that technological options could allow Mexico to achieve its emission reduction targets, albeit at a cost to the country.

09 BIOMASS FUELS↗

2D kinetic-ion simulations of inverted corona fusion targets

Laser-driven “inverted corona” fusion targets have attracted interest as a low-convergence neutron source and platform for studying kinetic physics. The scheme consists of a hollow or gas-filled spherical shell made of deuterated plastic. The shell has one or more laser entrance holes (LEH), resembling a spherical hohlraum. The laser passes through the LEH’s and illuminates the interior surface of the shell, ablating a plasma that travels inward towards the target center. Long ion mean free paths in the converging plasma can lead to significant interpenetration, atomic mix, and other kinetic effects. Here, in this work we report on numerical simulations of inverted corona targets using the kinetic-ion, fluid–electron hybrid particle-in-cell (PIC) approach in 2D RZ geometry. 2D simulations suggest that shape effects do not have a significant impact on plasma evolution and observed yield trends are primarily the result of 1D kinetic mix mechanisms. Simulations are also compared against available experimental data recorded at the OMEGA laser facility. In particular, synthetic x-ray emission images show good qualitative agreement with experimental results, albeit with an apparent timing discrepancy for the two-sided vacuum target. More generally, we demonstrate the potential of hybrid-PIC simulations for full-system modeling and experimental design, including collisional absorption of laser energy, plasma evolution, mix, and fusion burn.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Head-and-Neck Target Delineation Among Radiation Oncology Residents After a Teaching Intervention: A Prospective, Blinded Pilot Study

Purpose: We conducted this study to determine the feasibility of incorporating a teaching intervention on target delineation into the educational curriculum of a radiation oncology residency program and to assess the short-term effects on resident skills. Methods and Materials: The study schema consisted of a baseline evaluation, the teaching intervention, and a follow-up evaluation. At the baseline evaluation, the participants contoured three clinical tumor volumes (CTVs) (70 Gy, 59.4 Gy, and 54 Gy) on six contrast-enhanced axial computed tomography images of a de-identified patient with Stage T2N2bM0 squamous cell carcinoma of the right base of the tongue. The participants attended a series of head-and-neck oncology and anatomy seminars. The teaching intervention consisted of a didactic lecture and an interactive hands-on practical session designed to improve the knowledge and skills for target delineation in the head and neck. At the follow-up evaluation, the residents again contoured the CTVs. Results: Of the 14 eligible residents, 11 (79%) actually participated in the study. For all participants, but especially for those who had not had previous experience with head-and-neck target delineation, the teaching intervention was associated with improvement in the delineation of the node-negative neck (CTV 54 Gy contour). Regardless of clinical experience, participants had difficulty determining what should be included in the CTV 59.4 Gy contour to ensure adequate coverage of potential microscopic disease. Conclusion: Incorporating a teaching intervention into the education curriculum of a radiation oncology residency program is feasible and was associated with short-term improvements in target delineation skills. Subsequent interventions will require content refinement, additional validation, longer term follow-up, and multi-institutional collaboration.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Combined {sup 18}F-FDG-PET/CT Imaging in Radiotherapy Target Delineation for Head-and-Neck Cancer

Purpose: To evaluate the effect of the use of {sup 18}F-fluorodeoxyglucose (FDG)-positron emission tomography (PET)/computed tomography (CT) in radiotherapy target delineation for head-and-neck cancer compared with CT alone. Methods and Materials: A total of 38 consecutive patients with head-and-neck cancer were included in this study. The primary tumor sites were as follow: 20 oropharyngeal tumors, 4 laryngeal tumors, 2 hypopharyngeal tumors, 2 paranasal sinuses tumors, 9 nasopharyngeal tumors, and 1 parotid gland tumor. The FDG-PET and CT scans were performed with a dedicated PET/CT scanner in one session and then fused. Subsequently, patients underwent treatment planning CT with intravenous contrast enhancement. The radiation oncologist defined all gross tumor volumes (GTVs) using both the PET/CT and CT scans. Results: In 35 (92%) of 38 cases, the CT-based GTVs were larger than the PET/CT-based GTVs. The average total GTV from the CT and PET/CT scans was 34.54 cm{sup 3} (range, 3.56-109) and 29.38 cm{sup 3} (range, 2.87-95.02), respectively (p < 0.05). Separate analyses of the difference between the CT- and PET/CT-based GTVs of the primary tumor compared with the GTVs of nodal disease were not statistically significant. The comparison between the PET/CT-based and CT-based boost planning target volumes did not show a statistically significant difference. All patients were alive at the end of the follow-up period (range, 3-38 months). Conclusion: GTVs, but not planning target volumes, were significantly changed by the implementation of combined PET/CT. Large multicenter studies are needed to ascertain whether combined PET/CT in target delineation can influence the main clinical outcomes.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Target Definition by C11-Methionine-PET for the Radiotherapy of Brain Metastases

Purpose: To evaluate the ability of 11C-methionine positron emission tomography (MET-PET) to delineate target volumes for brain metastases and to investigate to what extent tumor growth is presented by magnetic resonance imaging (MRI) and MET-PET. Materials and Methods: Three observers undertook target definition in 19 patients with 95 brain metastases by MRI and MET-PET images. MRI gross target volume (GTV) (GTV-MRI) was defined as the contrast-enhanced area on gadolinium-enhanced T1-weighted MRI. MET-PET GTV (GTV-PET) was defined as the area of an accumulation of MET-PET apparently higher than that of normal tissue on MET-PET images. The size of occupation ratio was determined using the following equation: SOR (%) of MET are within x mm margin outside GTV-MRI = the volume of the GTV-PET within x mm outside the GTV-MRI/the volume of the GTV-PET. Results: For GTV-MRI volumes of {<=}0.5 mL, the sensitivity of tumor detection by MET-PET was 43%. For GTV-MRI volume of >0.5 mL, GTV-PET volumes were larger than GTV-MRI volumes and a significant correlation was found between these variables by linear regression. For all tumor sizes and tumor characteristics, a 2-mm margin outside the GTV-MRI significantly improved the coverage of the GTV-PET. Conclusions: Although there were some limitations in our study associated with spatial resolution, blurring effect, and image registrations with PET images, MET-PET was supposed to have a potential as a promising tool for the precise delineation of target volumes in radiotherapy planning for brain metastases.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Assessing the Effect of a Contouring Protocol on Postprostatectomy Radiotherapy Clinical Target Volumes and Interphysician Variation

Purpose: To compare postprostatectomy clinical target volume (CTV) delineation before and after the introduction of a contouring protocol and to investigate its effect on interphysician variability Methods and Materials: Six site-specialized radiation oncologists independently delineated a CTV on the computed tomography (CT) scans of 3 patients who had received postprostatectomy radiotherapy. At least 3 weeks later this was repeated, but with the physicians adhering to the contouring protocol from the Medical Research Council's Radiotherapy and Androgen Deprivation In Combination After Local Surgery (RADICALS) trial. The volumes obtained before and after the protocol were compared and the effect of the protocol on interphysician variability assessed. Results: An increase in mean CTV for all patients of 40.7 to 53.9cm{sup 3} was noted as a result of observing the protocol, with individual increases in the mean CTV of 65%, 15%, and 24% for Patients 1, 2, and 3 respectively. A reduction in interphysician variability was noted when the protocol was used. Conclusions: Substantial interphysician variation in target volume delineation for postprostatectomy radiotherapy exists, which can be reduced by the use of a contouring protocol. The RADICALS contouring protocol increases the target volumes when compared with those volumes typically applied at our center. The effect of treating larger volumes on the therapeutic ratio and resultant toxicity should be carefully monitored, particularly if the same dose-response as documented in radical prostate radiotherapy applies to the adjuvant and salvage setting. Prostate cancer, Postprostatectomy, Radiotherapy, Target volume.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

An Effective Preoperative Three-Dimensional Radiotherapy Target Volume for Extremity Soft Tissue Sarcoma and the Effect of Margin Width on Local Control

Purpose: There is little information on the appropriate three-dimensional (3D) preoperative radiotherapy (XRT) volume for extremity soft-tissue sarcomas (STS). We retrospectively analyzed the pattern of local failure (LF) to help elucidate optimal field design. Methods and Materials: We analyzed the 56 patients who underwent computed tomography-planned XRT for Stage I to III extremity STS between June 2000 and December 2006. Clinical target volume (CTV) included the T1 post-gadolinium-defined gross tumor volume with 1- to 1.5-cm radial and 3.5-cm longitudinal margins. Planning target volume expansion was 5 to 7 mm, and {>=}95% of dose was delivered to the planning target volume. Preoperative XRT was 44 to 50.4 Gy (median, 50). Postoperative boost of 10 to 20 Gy was given to 12 patients (6 with positive and 6 with close margins). Results: Follow-up ranged from 15 to 76 months (median, 41 months). The 5-year local control, freedom from distant metastasis, disease-free survival, and overall survival were 88.5%, 80.0%, 77.5% and 82.8%, respectively. Three patients (all with positive margin) experienced local failure (LF) as first relapse (2 isolated, 1 with distant failure), and 2 additional patients (all with margin<1 mm) had late LF after distant metastasis. The LFs were within the CTV in 3 patients and within and also extending beyond the CTV in 2 patients. Conclusions: These target volume definitions appear to be appropriate for most patients. No local recurrences were observed with surgical margins {>=}1 mm, and it appears that these may be adequate for patients with extremity STS treated with preoperative radiotherapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Membrane-Dependent Bystander Effect Contributes to Amplification of the Response to Alpha-Particle Irradiation in Targeted and Nontargeted Cells

Purpose: Free radicals are believed to play an active role in the bystander response. This study investigated their origin as well as their temporal and spatial impacts in the bystander effect. Methods and Materials: We employed a precise alpha-particle microbeam to target a small fraction of subconfluent osteoblastic cells (MC3T3-E1). gammaH2AX-53BP1 foci, oxidative metabolism changes, and micronuclei induction in targeted and bystander cells were assessed. Results: Cellular membranes and mitochondria were identified as two distinct reactive oxygen species producers. The global oxidative stress observed after irradiation was significantly attenuated after cells were treated with filipin, evidence for the primal role of membrane in the bystander effect. To determine the membrane's impact at a cellular level, micronuclei yield was measured when various fractions of the cell population were individually targeted while the dose per cell remained constant. Induction of micronuclei increased in bystander cells as well as in targeted cells and was attenuated by filipin treatment, demonstrating a role for bystander signals between irradiated cells in an autocrine/paracrine manner. Conclusions: A complex interaction of direct irradiation and bystander signals leads to a membrane-dependent amplification of cell responses that could influence therapeutic outcomes in tissues exposed to low doses or to environmental exposure.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dose Gradient Near Target-Normal Structure Interface for Nonisocentric CyberKnife and Isocentric Intensity-Modulated Body Radiotherapy for Prostate Cancer

Purpose: The treatment planning quality between nonisocentric CyberKnife (CK) and isocentric intensity modulation treatment was studied for hypofractionated prostate body radiotherapy. In particular, the dose gradient across the target and the critical structures such as the rectum and bladder was characterized. Methods and Materials: In the present study, patients treated with CK underwent repeat planning for nine fixed-field intensity-modulated radiotherapy (IMRT) using identical contour sets and dose-volume constraints. To calculate the dose falloff, the clinical target volume contours were expanded 30 mm anteriorly and posteriorly and 50 mm uniformly in other directions for all patients in the CK and IMRT plans. Results: We found that all the plans satisfied the dose-volume constraints, with the CK plans showing significantly better conformity than the IMRT plans at a relative greater dose inhomogeneity. The rectal and bladder volumes receiving a low dose were also lower for CK than for IMRT. The average conformity index, the ratio of the prescription isodose volume and clinical target volume, was 1.18 {+-} 0.08 for the CK plans vs. 1.44 {+-} 0.11 for the IMRT plans. The average homogeneity index, the ratio of the maximal dose and the prescribed dose to the clinical target volume, was 1.45 {+-} 0.12 for the CK plans vs. 1.28 {+-} 0.06 for the IMRT plans. The average percentage of dose falloff was 2.9% {+-} 0.8%/mm for CK and 3.1% {+-} 1.0%/mm for IMRT in the anterior direction, 3.8% {+-} 1.6%/mm for CK and 3.2% {+-} 1.9%/mm for IMRT in the posterior direction, and 3.6% {+-} 0.4% for CK and 3.6% {+-} 0.4% for IMRT in all directions. Conclusion: Nonisocentric CK was as capable of producing equivalent fast dose falloff as high-number fixed-field IMRT delivery.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Consensus Guidelines for Delineation of Clinical Target Volume for Intensity-Modulated Pelvic Radiotherapy for the Definitive Treatment of Cervix Cancer

Purpose: Accurate target definition is vitally important for definitive treatment of cervix cancer with intensity-modulated radiotherapy (IMRT), yet a definition of clinical target volume (CTV) remains variable within the literature. The aim of this study was to develop a consensus CTV definition in preparation for a Phase 2 clinical trial being planned by the Radiation Therapy Oncology Group. Methods and Materials: A guidelines consensus working group meeting was convened in June 2008 for the purposes of developing target definition guidelines for IMRT for the intact cervix. A draft document of recommendations for CTV definition was created and used to aid in contouring a clinical case. The clinical case was then analyzed for consistency and clarity of target delineation using an expectation maximization algorithm for simultaneous truth and performance level estimation (STAPLE), with kappa statistics as a measure of agreement between participants. Results: Nineteen experts in gynecological radiation oncology generated contours on axial magnetic resonance images of the pelvis. Substantial STAPLE agreement sensitivity and specificity values were seen for gross tumor volume (GTV) delineation (0.84 and 0.96, respectively) with a kappa statistic of 0.68 (p < 0.0001). Agreement for delineation of cervix, uterus, vagina, and parametria was moderate. Conclusions: This report provides guidelines for CTV definition in the definitive cervix cancer setting for the purposes of IMRT, building on previously published guidelines for IMRT in the postoperative setting.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Prospective Randomized Double-Blind Pilot Study of Site-Specific Consensus Atlas Implementation for Rectal Cancer Target Volume Delineation in the Cooperative Group Setting

Purpose: Variations in target volume delineation represent a significant hurdle in clinical trials involving conformal radiotherapy. We sought to determine the effect of a consensus guideline-based visual atlas on contouring the target volumes. Methods and Materials: A representative case was contoured (Scan 1) by 14 physician observers and a reference expert with and without target volume delineation instructions derived from a proposed rectal cancer clinical trial involving conformal radiotherapy. The gross tumor volume (GTV), and two clinical target volumes (CTVA, including the internal iliac, presacral, and perirectal nodes, and CTVB, which included the external iliac nodes) were contoured. The observers were randomly assigned to receipt (Group A) or nonreceipt (Group B) of a consensus guideline and atlas for anorectal cancers and then instructed to recontour the same case/images (Scan 2). Observer variation was analyzed volumetrically using the conformation number (CN, where CN = 1 equals total agreement). Results: Of 14 evaluable contour sets (1 expert and 7 Group A and 6 Group B observers), greater agreement was found for the GTV (mean CN, 0.75) than for the CTVs (mean CN, 0.46-0.65). Atlas exposure for Group A led to significantly increased interobserver agreement for CTVA (mean initial CN, 0.68, after atlas use, 0.76; p = .03) and increased agreement with the expert reference (initial mean CN, 0.58; after atlas use, 0.69; p = .02). For the GTV and CTVB, neither the interobserver nor the expert agreement was altered after atlas exposure. Conclusion: Consensus guideline atlas implementation resulted in a detectable difference in interobserver agreement and a greater approximation of expert volumes for the CTVA but not for the GTV or CTVB in the specified case. Visual atlas inclusion should be considered as a feature in future clinical trials incorporating conformal RT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Impact of [{sup 11}C]Methionine Positron Emission Tomography for Target Definition of Glioblastoma Multiforme in Radiation Therapy Planning

Purpose: The purpose of this work was to define the optimal margins for gadolinium-enhanced T{sub 1}-weighted magnetic resonance imaging (Gd-MRI) and T{sub 2}-weighted MRI (T{sub 2}-MRI) for delineating target volumes in planning radiation therapy for postoperative patients with newly diagnosed glioblastoma multiforme (GBM) by comparison to carbon-11-labeled methionine positron emission tomography ([{sup 11}C]MET-PET) findings. Methods and Materials: Computed tomography (CT), MRI, and [{sup 11}C]MET-PET were separately performed for radiation therapy planning for 32 patients newly diagnosed with GBM within 2 weeks after undergoing surgery. The extent of Gd-MRI (Gd-enhanced clinical target volume [CTV-Gd]) uptake and that of T{sub 2}-MRI of the CTV (CTV-T{sub 2}) were compared with the extent of [{sup 11}C]MET-PET (CTV--[{sup 11}C]MET-PET) uptake by using CT--MRI or CT--[{sup 11}C]MET-PET fusion imaging. We defined CTV-Gd (x mm) and CTV-T{sub 2} (x mm) as the x-mm margins (where x = 0, 2, 5, 10, and 20 mm) outside the CTV-Gd and the CTV-T{sub 2}, respectively. We evaluated the relationship between CTV-Gd (x mm) and CTV-- [{sup 11}C]MET-PET and the relationship between CTV-T{sub 2} (x mm) and CTV-- [{sup 11}C]MET-PET. Results: The sensitivity of CTV-Gd (20 mm) (86.4%) was significantly higher than that of the other CTV-Gd. The sensitivity of CTV-T{sub 2} (20 mm) (96.4%) was significantly higher than that of the other CTV-T{sub 2} (x = 0, 2, 5, 10 mm). The highest sensitivity and lowest specificity was found with CTV-T{sub 2} (x = 20 mm). Conclusions: It is necessary to use a margin of at least 2 cm for CTV-T{sub 2} for the initial target planning of radiation therapy. However, there is a limit to this setting in defining the optimal margin for Gd-MRI and T{sub 2}-MRI for the precise delineation of target volumes in radiation therapy planning for postoperative patients with GBM.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Molecular Profiling to Optimize Treatment in Non-Small Cell Lung Cancer: A Review of Potential Molecular Targets for Radiation Therapy by the Translational Research Program of the Radiation Therapy Oncology Group

Therapeutic decisions in non-small cell lung cancer (NSCLC) have been mainly based on disease stage, performance status, and co-morbidities, and rarely on histological or molecular classification. Rather than applying broad treatments to unselected patients that may result in survival increase of only weeks to months, research efforts should be, and are being, focused on identifying predictive markers for molecularly targeted therapy and determining genomic signatures that predict survival and response to specific therapies. The availability of such targeted biologics requires their use to be matched to tumors of corresponding molecular vulnerability for maximum efficacy. Molecular markers such as epidermal growth factor receptor (EGFR), K-ras, vascular endothelial growth factor (VEGF), mammalian target of rapamycin (mTOR), and anaplastic lymphoma kinase (ALK) represent potential parameters guide treatment decisions. Ultimately, identifying patients who will respond to specific therapies will allow optimal efficacy with minimal toxicity, which will result in more judicious and effective application of expensive targeted therapy as the new paradigm of personalized medicine develops.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Identification and Characterization of a Small Inhibitory Peptide That Can Target DNA-PKcs Autophosphorylation and Increase Tumor Radiosensitivity

Purpose: The DNA protein kinase catalytic subunit (DNA-PKcs) is one of the critical elements involved in the DNA damage repair process. Inhibition of DNA-PKcs results in hypersensitivity to ionizing radiation (IR); therefore, this approach has been explored to develop molecular targeted radiosensitizers. Here, we aimed to develop small inhibitory peptides that could specifically target DNA-PKcs autophosphorylation, a critical step for the enzymatic activation of the kinase in response to IR. Methods and Materials: We generated several small fusion peptides consisting of 2 functional domains, 1 an internalization domain and the other a DNA-PKcs autophosphorylation inhibitory domain. We characterized the internalization, toxicity, and radiosensitization activities of the fusion peptides. Furthermore, we studied the mechanisms of the inhibitory peptides on DNA-PKcs autophosphorylation and DNA repair. Results: We found that among several peptides, the biotin-labeled peptide 3 (BTW3) peptide, which targets DNA-PKcs threonine 2647 autophosphorylation, can abrogate IR-induced DNA-PKcs activation and cause prolonged {gamma}-H2AX focus formation. We demonstrated that BTW3 exposure led to hypersensitivity to IR in DNA-PKcs-proficient cells but not in DNA-PKcs-deficient cells. Conclusions: The small inhibitory peptide BTW3 can specifically target DNA-PKcs autophosphorylation and enhance radiosensitivity; therefore, it can be further developed as a novel class of radiosensitizer.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Verification of Planning Target Volume Settings in Volumetric Modulated Arc Therapy for Stereotactic Body Radiation Therapy by Using In-Treatment 4-Dimensional Cone Beam Computed Tomography

Purpose: To evaluate setup error and tumor motion during beam delivery by using 4-dimensional cone beam computed tomography (4D CBCT) and to assess the adequacy of the planning target volume (PTV) margin for lung cancer patients undergoing volumetric modulated arc therapy for stereotactic body radiation therapy (VMAT-SBRT). Methods and Materials: Fifteen lung cancer patients treated by single-arc VMAT-SBRT were selected in this analysis. All patients were treated with an abdominal compressor. The gross tumor volumes were contoured on maximum inspiration and maximum expiration CT datasets from 4D CT respiratory sorting and merged into internal target volumes (ITVs). The PTV margin was isotropically taken as 5 mm. Registration was automatically performed using “pre-3D” CBCT. Treatment was performed with a D95 prescription of 50 Gy delivered in 4 fractions. The 4D tumor locations during beam delivery were determined using in-treatment 4D CBCT images acquired in each fraction. Then, the discrepancy between the actual tumor location and the ITV was evaluated in the lateral, vertical, and longitudinal directions. Results: Overall, 55 4D CBCT sets during VMAT-SBRT were successfully obtained. The amplitude of tumor motion was less than 10 mm in all directions. The average displacements between ITV and actual tumor location during treatment were 0.41 ± 0.93 mm, 0.15 ± 0.58 mm, and 0.60 ± 0.99 mm for the craniocaudal, left-right, and anteroposterior directions, respectively. The discrepancy in each phase did not exceed 5 mm in any direction. Conclusions: With in-treatment 4D CBCT, we confirmed the required PTV margins when the registration for moving target was performed using pre-3D CBCT. In-treatment 4D CBCT is a direct method for quantitatively assessing the intrafractional location of a moving target.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Sparing Healthy Tissue and Increasing Tumor Dose Using Bayesian Modeling of Geometric Uncertainties for Planning Target Volume Personalization

Objective: To develop a mathematical tool that can update a patient's planning target volume (PTV) partway through a course of radiation therapy to more precisely target the tumor for the remainder of treatment and reduce dose to surrounding healthy tissue. Methods and Materials: Daily on-board imaging was used to collect large datasets of displacements for patients undergoing external beam radiation therapy for solid tumors. Bayesian statistical modeling of these geometric uncertainties was used to optimally trade off between displacement data collected from previously treated patients and the progressively accumulating data from a patient currently partway through treatment, to optimally predict future displacements for that patient. These predictions were used to update the PTV position and margin width for the remainder of treatment, such that the clinical target volume (CTV) was more precisely targeted. Results: Software simulation of dose to CTV and normal tissue for 2 real prostate displacement datasets consisting of 146 and 290 patients treated with a minimum of 30 fractions each showed that re-evaluating the PTV position and margin width after 8 treatment fractions reduced healthy tissue dose by 19% and 17%, respectively, while maintaining CTV dose. Conclusion: Incorporating patient-specific displacement patterns from early in a course of treatment allows PTV adaptation for the remainder of treatment. This substantially reduces the dose to healthy tissues and thus can reduce radiation therapy–induced toxicities, improving patient outcomes.

62 RADIOLOGY AND NUCLEAR MEDICINE↗