Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SAMPLE POSITIONING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,351 records · Page 75

Optical pseudomotors for soft x-ray beamlines

Optical elements of soft x-ray beamlines usually have motorized translations and rotations that allow for the fine alignment of the beamline. This is to steer the photon beam at some positions and to correct the focus on slits or on sample. Generally, each degree of freedom of a mirror induces a change of several parameters of the beam. Inversely, several motions are required to actuate on a single optical parameter, keeping the others unchanged. We define optical pseudomotors as combinations of physical motions of the optical elements of a beamline, which allow modifying one optical parameter without affecting the others. We describe a method to obtain analytic relationships between physical motions of mirrors and the corresponding variations of the beam parameters. This method has been implemented and tested at two beamlines at ALBA, where it is used to control the focus of the photon beam and its position independently.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Nanomanipulation and Lithography for Carbon Nanotube Based Nondestructive Evaluation Sensor Development

Carbon nanotubes (CNTs) offer great potential for advanced sensor development due to the unique electronic transport properties of the material. However, a significant obstacle to the realization of practical CNT devices is the formation of reliable and reproducible CNT to metallic contacts. In this work, scanning probe techniques are explored for both fabrication of metallic junctions and positioning of singlewalled CNTs across these junctions. The use of a haptic force feedback interface to a scanning probe microscope is used to enable movement of nanotubes over micron length scales with nanometer precision. In this case, imaging of the surface is performed with light or intermittent contact to the surface. Increased tip-to-sample interaction forces are then applied to either create junctions or position CNTs. The effect of functionalization of substrate surfaces on the movement and tribology of the materials is also studied. The application of these techniques to the fabrication of CNT-based sensors for nondestructive evaluation applications is discussed.

Wincheski, Buzz↗

A scanning CCD detector for powder diffraction measurements

Several different approaches have traditionally been used for detection of X-ray powder diffraction patterns, including area detectors, point detectors and position-sensitive detectors. Each has advantages. This paper discusses use of a low-cost CCD detector attached to a diffractometer arm, where line-by-line readout of the CCD is coupled to continuous motion of the arm. When this type of detector is used and where X-ray optics are employed to focus the source image onto the detector plane both high-resolution and rapid measurements can be performed, with data collection over a complete 2θ range. This is particularly advantageous for synchrotron applications but valuable also for Guinier diffractometer laboratory instruments. Peak resolutions are shown to be moderately better than what can be obtained with a position-sensitive detector and significantly better than with an area detector. Many samples have intrinsically broadened peak shapes for which little improvement in data quality could be obtained with an analyzer-crystal detector. With comparable numbers of modules, these CCD data collection speeds can be close to those with position-sensitive detectors, but without the low-angle asymmetry seen in the latter.

Toby, B. H.↗

A study of radiation damage effects on the magnetic structure of bulk Iron

Defects, defect interactions, and defect dynamics in solids created by fast neutrons are known to have significant impact on the performance and lifetime of structural materials. A fundamental understanding of the radiation damage effects in solids is therefore of great importance in assisting the development of improved materials - materials with ultrahigh strength, toughness, and radiation resistance. In this presentation, we show our recent theoretical investigation on the magnetic structure evolution of bulk iron in the region of the radiation defects. We applied a linear scaling ab-initio method based on density functional theory with local spin density approximation, namely the locally self-consistent multiple scattering method (LSMS), to the study of magnetic moment distributions in a cascade at the damage peak and for a series of time steps as the interstitials and vacancies recombined. Atomic positions correspond to those in a low energy cascade in a 10|000 atom sample, in which the primary damage state and the evolution of all defects produced were simulated using molecular dynamics with empirical, embedded-atom inter-atomic potentials. We will discuss how a region of affected moments expands and then recedes in response to a cascade evolution.

36 MATERIALS SCIENCE↗

Toward quantitative deuterium analysis with laser-induced breakdown spectroscopy using atmospheric-pressure helium gas

An experimental study has been carried out for the development of quantitative deuterium analysis using the neodymium doped yttrium aluminum garnet laser-induced breakdown spectroscopy (LIBS) with atmospheric pressure surrounding He gas by exploring the appropriate experimental condition and special sample cleaning technique. The result demonstrates the achievement of a full resolution between the D and H emission lines from zircaloy-4 samples, which is prerequisite for the desired quantitative analysis. Further, a linear calibration line with zero intercept was obtained for the emission intensity of deuterium from a number of zircaloy samples doped with predetermined concentrations of deuterium. The result is obtained by setting a +4 mm defocusing position for the laser beam, 6 {mu}s detection gating time, and 7 mm imaging position of the plasma for the detection, which is combined with a special procedure of repeated laser cleaning of the samples. This study has thus provided the basis for the development of practical quantitative deuterium analysis by LIBS.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Discovering Strong Gravitational Lenses in the Dark Energy Survey with Interactive Machine Learning and Crowd-sourced Inspection with Space Warps

We conduct a search for strong gravitational lenses in the Dark Energy Survey (DES) Year 6 imaging data. We implement a pre-trained Vision Transformer (ViT) for our machine learning (ML) architecture and adopt interactive machine learning to construct a training sample with multiple classes to address common types of false positives. Our ML model reduces ∼236 million DES cutout images to 22,564 targets of interest, including ∼85% of previously reported galaxy–galaxy lens candidates discovered in DES. These targets were visually inspected by citizen scientists, who ruled out ∼90% as false positives. Of the remaining 2618 candidates, 149 were expert-classified as “definite” lenses and 516 as “probable” lenses, for a total of 665 systems, with 147 of these candidates being newly identified. Additionally, we trained a second ViT to find double-source plane lens systems, finding at least one double-source system. Our main ViT excels at identifying galaxy–galaxy lenses, consistently assigning high scores to candidates with high expert assessments. The top 800 ViT-scored images include ∼100 of our “definite” lens candidates. This selection is an order of magnitude higher in purity than previous convolutional neural-network-based lens searches and demonstrates the feasibility of applying our methodology for discovering large samples of lenses in future surveys.

79 ASTRONOMY AND ASTROPHYSICS↗

Field‐Induced Ferroelectric Phase Evolution During Polarization “Wake‐Up” in Hf 0.5 Zr 0.5 O 2 Thin Film Capacitors

Abstract As an emerging nonvolatile memory technology, HfO 2 ‐based ferroelectrics exhibit excellent compatibility with silicon CMOS process flows; however, the reliability of polarization switching in these materials remains a major challenge. During repeated field programming and erase of the polarization state of initially pristine HfO 2 ‐based ferroelectric capacitors, the magnitude of the measured polarization increases, a phenomenon known as “wake‐up”. In this study, the authors attempt to understand what causes the wake‐up effect in Hf 0.5 Zr 0.5 O 2 (HZO) capacitors using nondestructive methods that probe statistically significant sample volumes. Synchrotron X‐ray diffraction reveals a concerted shift in HZO Bragg peak position as a function of polarization switching cycle number in films prepared under conditions such that they exhibit extremely large (≈3000%) wake‐up. In contrast, a control sample with insignificant wake‐up shows no such peak shift. Capacitance – voltage measurements show evolution in the capacitance loop with switching cycle number for the wake‐up sample and no change for the control sample. Piezoresponse force microscopy measurements are utilized to visualize the domain switching with wake‐up. The combination of these observations clearly demonstrates that wake‐up is caused by a field‐driven phase transformation of the tetragonal phase to the metastable ferroelectric orthorhombic phase during polarization switching of HZO capacitors.

36 MATERIALS SCIENCE↗

Low-luminosity active galaxies: Are they similar to Seyfert galaxies?

A careful X-ray study of five low-luminosity active galactic nuclei (LLAGNs) was conducted to address specifically the issue of whether the dominant X-ray production mechanism is the same at all luminosities in AGNs. The sample consists of three Seyfert 1 galaxies (NGC 4639, NGC 5033, and NGC 5273), and two low-ionization nuclear emission-line regions (NGC 3642 and NGC 4278) having a weak broad component of H-alpha emission. We find that the X-ray emission (ROSAT High Resolution Interferometer (HRI)) is mostly or entirely nuclear (less than or approximately = 500 pc) despite the low X-ray luminosities (approximately 9 x 10(exp 40) ergs/s) of the sample. The correlation between X-ray luminosity and the broad H-alpha emission-line luminosity observed in high-luminosity active galaxies continues down to the low-luminosity range; the mean L(sub X)/L(sub H-alpha) ratio of LLAGNs is approximately 14, while that of AGNs is approximately 29. ROSAT Position Sensitive Proportional Counter (PSPC) observations of three LLAGNs in our sample indicate that the 0.2-2.2 keV X-ray spectral energy distributions are similar to those seen in Seyfert nuclei but do not have high intrinsic absorbing columns. Using existing ultraviolet data for four LLAGNs, we find that the 'optical' (2500 A) to X-ray spectral index (alpha(sub OX)) has an average upper limit of 1.6; for comparison, the measured value in AGNs is typically 1.4, while that in M81 (the prototypical LLAGN) is 1.0.

Koratkar, A.↗

An international laboratory comparison of dissolved organic matter composition by high resolution mass spectrometry: Are we getting the same answer?

Since the first detailed compositional analysis of dissolved organic matter (DOM) in 1995, high resolution mass spectrometry (HRMS) has become a vital tool for DOM characterization. While the upward trend in HRMS for molecular level analysis of DOM continues, so do the challenges of data comparison and interpretation between laboratories operating instruments of differing performance and user operating conditions. It is therefore essential that the community establishes whether data and trends can be compared robustly between research groups. To this end, 4 identically prepared DOM samples were each studied by 16 laboratories, representing 17 commercially-purchased instruments located across 8 countries, using positive- and negative-mode electrospray ionization (ESI) HRMS analysis. Despite the widely reported sensitivity of ESI experiments to sample matrix, preparation, ion source operation and instrument tuning parameters, the instruments used in this study showed relatively low variability between results for the same samples, particularly H/C and AI metrics. The variation in O/C and m/z metrics was relatively higher, although z-score graphs and %BCD demonstrated that the relative difference in general chemical composition between samples was the same for each instrument included in the study. As such, these metrics can be used for fingerprinting of DOM samples and as a benchmark for quality control in participating laboratories, with future strides in environmental science building upon these efforts.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Attractive Improvement in Structural, Magnetic, Optical, and Antimicrobial Activity of Silver Delafossite by Fe/Cr Doping

This paper presented a novel method of AgX O{sub 2} (X = Fe or Cr) delafossite using flash auto-combustion technique. X-ray diffraction pattern (XRD) clarified single-phase structure. The morphology was analyzed by high-resolution transmission electron microscopy (HRTEM) and field emission scanning electron microscopy (FESEM). The composition of the samples was determined using energy dispersive X-ray (EDX) analysis. The particle size estimated from HRTEM, FESEM, and XRD analyses revealed that the samples were in the nanoscale range. The magnetic hysteresis loop of the samples was measured at room temperature (300 K) and at low temperatures (200 and 100 K). Rare behavior by shifting the hysteresis loop horizontally was observed for AgCrO{sub 2} delafossite at low temperatures (200 and 100 K). The optical properties were measured for the investigated samples. The antimicrobial study promoted that AgFeO{sub 2} delafossite had a strong antibacterial activity against Gram-positive and Gram-negative bacteria than that of AgCrO{sub 2} delafossite. However, no activity appeared for both samples against fungus micro-organisms. As a result, AgFeO{sub 2} delafossite could be applied in cancer diagnoses, biomedical applications, and energy storage in solar cell. Moreover, AgCrO{sub 2} delafossite could be applied as a photocathode in a dye-sensitized solar cell and biomedical applications.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A sensitivity analysis to predict the neutronics behavior of samples irradiated in the VTR rabbit system

We report a low-order neutronics model is developed to carry out hundreds of simulations efficiently and investigate the neutronics behavior of samples being irradiated in a test reactor setting under different geometrical constraints. The low-order model allowed for simulations that yield the expected neutronics behavior of any irradiated sample in any environment and allows for the calculation of highly accurate spatially averaged statistics and idealized spatial distributions in the neutron flux. Several benchmarks are performed to evaluate the performance and limitations of the low-order model revealing many important findings. The low-order model predicted the LHGR in the EBR-II driver fuel to within 2.34% by only simulating the fuel rod by itself, which served as a validation for the model. Sensitivity studies investigated 3% enriched UO 2 and U-10Zr being irradiated in the Versatile Test Reactor rabbit system. The analyses investigated a range of combinations of 15 radii and 5 heights for each sample in the rabbit system. Similar data sets are also provided for irradiations in the Advanced Test Reactor’s B-10 irradiation position, which is a thermal neutron spectrum environment. Generalized fits and fit coefficients are obtained for sample heating, reaction rate densities, and local multiplication rate characteristics, allowing the predictions of the neutronics behavior of the samples based on their geometrical constraints. The analyses and fits laid the groundwork for developing a user-end Multiphysics analysis framework to assist and accelerate irradiation experiment design and optimization.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Dielectric functions and carrier concentrations of Hg{sub 1−x}Cd{sub x}Se films determined by spectroscopic ellipsometry

Spectroscopic ellipsometry, ranging from 35 meV to 6 eV, was used to determine the dielectric functions of a series of molecular beam epitaxy-grown Hg{sub 1−x}Cd{sub x}Se thin films deposited on both ZnTe/Si(112) and GaSb(112) substrates. The fundamental band gap as well as two higher-order electronic transitions blue-shift with increasing Cd composition in Hg{sub 1−x}Cd{sub x}Se, as expected. Representing the free carrier absorption with a Drude oscillator, we found that the effective masses of Hg{sub 1−x}Cd{sub x}Se (grown on ZnTe/Si) vary between 0.028 and 0.050 times the free electron mass, calculated using the values of carrier concentration and the mobility obtained through Hall measurements. Using these effective masses, we determined the carrier concentrations of Hg{sub 1−x}Cd{sub x}Se samples grown on GaSb, which is of significance as films grown on such doped-substrates posit ambiguous results when measured by conventional Hall experiments. These models can serve as a basis for monitoring Cd-composition during sample growth through in-situ spectroscopic ellipsometry.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Quantitative comparison of bright field and annular bright field imaging modes for characterization of oxygen octahedral tilts

Octahedral tilt behavior is increasingly recognized as an important contributing factor to the physical behavior of perovskite oxide materials and especially their interfaces, necessitating the development of high-resolution methods of tilt mapping. There are currently two major approaches for quantitative imaging of tilts in scanning transmission electron microscopy (STEM), bright field (BF) and annular bright field (ABF). In this study, we show that BF STEM can be reliably used for measurements of oxygen octahedral tilts. While optimal conditions for BF imaging are more restricted with respect to sample thickness and defocus, we find that BF imaging with an aberration-corrected microscope with the accelerating voltage of 300 kV gives us the most accurate quantitative measurement of the oxygen column positions. Using the tilted perovskite structure of BiFeO 3 (BFO) as our test sample, we simulate BF and ABF images in a wide range of conditions, identifying the optimal imaging conditions for each mode. Finally, we show that unlike ABF imaging, BF imaging remains directly quantitatively interpretable for a wide range of the specimen mistilt, suggesting that it should be preferable to the ABF STEM imaging for quantitative structure determination.

36 MATERIALS SCIENCE↗

A Minority Report Submitted as an Addendum to the Report of the Mars 2020 Organic Contamination Panel

This Minority Report (MR) presents seven findings in addition to or contrary to the main OCP report: 1. Contamination control for the Mars 2020 cache must be strict. Mars’ surface is known to be organics-poor from laboratory studies, Mars meteorite analyses, and from four previous NASA missions. It is imperative that contamination control measures are enacted that enable reliable and robust detection of potential biomarker compounds at the ppb level. 2. Since Mars 2020 is a sample return mission and analyses of samples in the returnable cache are expected to occur after return to Earth, positive controls are not recommended for flight on Mars 2020 unless a compelling case can be made for their use. 3. The findings of previous panels dedicated to organic compound analysis in Martian samples (OCSSG, ND-SAG, SDT) recommend TOC limits between 10-40 ppb. The MR finds that the lower limit of 10 ppb is recommended and that insufficient justification is given by the OCP Panel Report (PR) to raise the TOC limit to 40 ppb. 4. Analytical capability is sufficiently advanced that analytical capability is an irrelevant consideration with respect to differentiating between 10 and 40 ppb TOC. 5. Perceived contamination control challenges are an irrelevant consideration for raising the TOC contamination limit from 10 to 40 ppb since those challenges, and the procedures to ameliorate them, will exist regardless of whether the limit is 10 or 40 ppb. 6. The “dilution cleaning” method has not been adequately proven for utilization on the Mars 2020 mission. Shortcomings have been identified in terms of peer review, method verification, analytical and testing approach, application to space flight hardware, and performance under Martian conditions. The method should be revisited and independently tested using statistically and analytically robust methods, and scrutinized in a rigorous peer review process. 7. The Mars 2020 mission claims considerable heritage from the Mars Science Laboratory (MSL) mission, but MSL contamination control efforts contain significant errors and implementation discrepancies that would imperil the Mars 2020 caching mission were they repeated. A standing contamination control panel should be formed to provide independent oversight for the Mars 2020 mission.

Mars Sample Return↗

Real-time catheter tracking for high-dose-rate prostate brachytherapy using an electromagnetic 3D-guidance device: A preliminary performance study

Purpose: In order to increase the accuracy and speed of catheter reconstruction in a high-dose-rate (HDR) prostate implant procedure, an automatic tracking system has been developed using an electromagnetic (EM) device (trakSTAR, Ascension Technology, VT). The performance of the system, including the accuracy and noise level with various tracking parameters and conditions, were investigated. Methods: A direct current (dc) EM transmitter (midrange model) and a sensor with diameter of 1.3 mm (Model 130) were used in the trakSTAR system for tracking catheter position during HDR prostate brachytherapy. Localization accuracy was assessed under both static and dynamic analyses conditions. For the static analysis, a calibration phantom was used to investigate error dependency on operating room (OR) table height (bottom vs midposition vs top), sensor position (distal tip of catheter vs connector end of catheter), direction [left-right (LR) vs anterior-posterior (AP) vs superior-inferior (SI)], sampling frequency (40 vs 80 vs 120 Hz), and interference from OR equipment (present vs absent). The mean and standard deviation of the localization offset in each direction and the corresponding error vectors were calculated. For dynamic analysis, the paths of five straight catheters were tracked to study the effects of directions, sampling frequency, and interference of EM field. Statistical analysis was conducted to compare the results in different configurations. Results: When interference was present in the static analysis, the error vectors were significantly higher at the top table position (3.3 {+-} 1.3 vs 1.8 {+-} 0.9 mm at bottom and 1.7 {+-} 1.0 mm at middle, p < 0.001), at catheter end position (3.1 {+-} 1.1 vs 1.4 {+-} 0.7 mm at the tip position, p < 0.001), and at 40 Hz sampling frequency (2.6 {+-} 1.1 vs 2.4 {+-} 1.5 mm at 80 Hz and 1.8 {+-} 1.1 at 160 Hz, p < 0.001). So did the mean offset errors in the LR direction (-1.7 {+-} 1.4 vs 0.4 {+-} 0.5 mm in AP and 0.8 {+-} 0.8 mm in SI directions, p < 0.001). The error vectors were significantly higher with surrounding interference (2.2 {+-} 1.3 mm) vs without interference (1.0 {+-} 0.7 mm, p < 0.001). An accuracy of 1.6 {+-} 0.2 mm can be reached when using optimum configuration (160 Hz at middle table position). When interference was present in the dynamic tracking, the mean tracking errors in LR direction (1.4 {+-} 0.5 mm) was significantly higher than that in AP direction (0.3 {+-} 0.2 mm, p < 0.001). So did the mean vector errors at 40 Hz (2.1 {+-} 0.2 mm vs 1.3 {+-} 0.2 mm at 80 Hz and 0.9 {+-} 0.2 mm at 160 Hz, p < 0.05). However, when interference was absent, they were comparable in the both directions and at all sampling frequencies. An accuracy of 0.9 {+-} 0.2 mm was obtained for the dynamic tracking when using optimum configuration. Conclusions: The performance of an EM tracking system depends highly on the system configuration and surrounding environment. The accuracy of EM tracking for catheter reconstruction in a prostate HDR brachytherapy procedure can be improved by reducing interference from surrounding equipment, decreasing distance from transmitter to tracking area, and choosing appropriated sampling frequency. A calibration scheme is needed to further reduce the tracking error when the interference is high.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

On the validity of the Poisson assumption in sampling nanometer-sized aerosols

A Poisson process is traditionally believed to apply to the sampling of aerosols. For a constant aerosol concentration, it is assumed that a Poisson process describes the fluctuation in the measured concentration because aerosols are stochastically distributed in space. Recent studies, however, have shown that sampling of micrometer-sized aerosols has non-Poissonian behavior with positive correlations. The validity of the Poisson assumption for nanometer-sized aerosols has not been examined and thus was tested in this study. Its validity was tested for four particle sizes - 10 nm, 25 nm, 50 nm and 100 nm - by sampling from indoor air with a DMA- CPC setup to obtain a time series of particle counts. Five metrics were calculated from the data: pair-correlation function (PCF), time-averaged PCF, coefficient of variation, probability of measuring a concentration at least 25% greater than average, and posterior distributions from Bayesian inference. To identify departures from Poissonian behavior, these metrics were also calculated for 1,000 computer-generated Poisson time series with the same mean as the experimental data. For nearly all comparisons, the experimental data fell within the range of 80% of the Poisson-simulation values. Essentially, the metrics for the experimental data were indistinguishable from a simulated Poisson process. The greater influence of Brownian motion for nanometer-sized aerosols may explain the Poissonian behavior observed for smaller aerosols. Although the Poisson assumption was found to be valid in this study, it must be carefully applied as the results here do not definitively prove applicability in all sampling situations.

concentration measurement↗

Pore-Scale Study on the Positive Feedback Between Stress and Porosity Caused by Pressure Solution in Porous Media

Pressure solution is an important process in the evolution of sedimentary rocks, which provide storage space for most of our petroleum resources. It directly influences the generation, migration, and storage of petroleum fluids in subsurface sedimentary rocks. Here, in this paper, we develop a pore-scale, mechanochemical model to demonstrate a possible positive feedback between the local porosity and pore surface stress, in which a higher local porosity causes a higher local pore surface stress, thus enhancing pressure solution and consequently further increasing the local porosity. Pore surface stress represents stress on a solid grain adjacent to a pore. Specifically, the pore-scale, mechanochemical model directly simulates the stress distribution over solid and pore surfaces using a finite element model. The dissolution of solids at the solid-pore interfaces under a far-from-equilibrium condition is simulated using a first-order kinetics model that accounts for the local stress distribution. The updated pore geometry, caused by pore surface dissolution, is then used in the stress simulation in the next numerical iteration. Two types of porous media, the Oriskany sandstone and an artificial porous medium with spherical pores, were tested in the mechanochemical simulation. The positive stress-porosity feedback during pressure solution was observed in both samples. In addition, the model quantitatively illustrated the distribution of local mineral dissolution rates on all pore surfaces, as well as its relation to the effective mineral dissolution rate of the entire sample. Based on the comparison between the two porous media, the local mineral dissolution was regulated by pore space distribution, geometry, and coalescence during pressure solution. This work is the first that uses direct, pore-scale numerical simulation to demonstrate the positive stress-porosity feedback during pressure solution, which has the potential to advance the understanding of the mechanical-chemical (MC) coupling in many geological processes that are relevant to subsurface energy systems, such as the recovery of petroleum hydrocarbons and geothermal energy.

CT scanning↗

Mosquito-Borne Viruses and Insect-Specific Viruses Revealed in Field-Collected Mosquitoes by a Monitoring Tool Adapted from a Microbial Detection Array

Several mosquito-borne diseases affecting humans are emerging or reemerging in the United States. The early detection of pathogens in mosquito populations is essential to prevent and control the spread of these diseases. Here, we tested the potential applicability of the Lawrence Livermore Microbial Detection Array (LLMDA) to enhance biosurveillance by detecting microbes present in Aedes aegypti, Aedes albopictus, and Culex mosquitoes, which are major vector species globally, including in Texas. The sensitivity and reproducibility of the LLMDA were tested in mosquito samples spiked with different concentrations of dengue virus (DENV), revealing a detection limit of >100 but <1,000 PFU/ml. Additionally, field-collected mosquitoes from Chicago, IL, and College Station, TX, of known infection status (West Nile virus [WNV] and Culex flavivirus [CxFLAV] positive) were tested on the LLMDA to confirm its efficiency. Mosquito field samples of unknown infection status, collected in San Antonio, TX, and the Lower Rio Grande Valley (LRGV), TX, were run on the LLMDA and further confirmed by PCR or quantitative PCR (qPCR). The analysis of the field samples with the LLMDA revealed the presence of cell-fusing agent virus (CFAV) in A. aegypti populations. Wolbachia was also detected in several of the field samples (A. albopictus and Culex spp.) by the LLMDA. Our findings demonstrated that the LLMDA can be used to detect multiple arboviruses of public health importance, including viruses that belong to the Flavivirus, Alphavirus, and Orthobunyavirus genera. Additionally, insect-specific viruses and bacteria were also detected in field-collected mosquitoes. Another strength of this array is its ability to detect multiple viruses in the same mosquito pool, allowing for the detection of cocirculating pathogens in an area and the identification of potential ecological associations between different viruses. Finally, this array can aid in the biosurveillance of mosquito-borne viruses circulating in specific geographical areas.

59 BASIC BIOLOGICAL SCIENCES↗