Optimal operation of multi-plant steam district heating systems for enhanced efficiency and sustainability

Despite their crucial role in supplying heat and power to universities, industries, and healthcare facilities, many steam-based district heating systems rely on outdated control methods. Among these, multi-central plant districts are particularly challenging due to the complexities of coordinating multiple plants, optimizing load distributions, and managing system downtime. In response, new operational strategies are developed to enhance the efficiency and sustainability of steam districts while utilizing existing resources. These strategies include reducing plant operational pressure without compromising the reliable supply to buildings and optimizing load allocation across multiple plants. The load allocation considers boiler part-load efficiency, runtime, network losses, and building pressure set points, and is compared with traditional multi-boiler controls. To support this exploration, new dynamic Modelica models are developed. In addition, methods to reduce modeling complexities are incorporated, enhancing their suitability for practical applications. A holistic district-wide analysis using a real university case study demonstrates a 4.7% fuel savings by lowering boiler operational pressure from 900 kPa to 600 kPa, along with a 13.3% reduction in condensation losses across the distribution network. Furthermore, the load allocation approach results in a 13.1% reduction in fuel consumption during peak winter periods and 15.3% during shoulder periods, with corresponding decreases in carbon emissions and fuel costs. This approach can also save maintenance costs by reducing the boiler runtime by 49.6%. In conclusion, this research underscores the benefits of retrofitting aging steam district heating systems, offering immediate operational improvements by enhancing efficiency, meeting regulatory compliance, and extending infrastructure lifespans while delaying costly overhauls.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Estimating residential energy consumption in metropolitan areas: A microsimulation approach

Prior research has shown that land use patterns and the spatial configurations of cities have a significant impact on residential energy demand. Given the pressing issues surrounding energy security and climate change, there is renewed interest in developing and retrofitting cities to make them more energy efficient. Yet deriving micro-scale residential energy footprints of metropolitan areas is challenging because high resolution data from energy providers is generally unavailable. In this study, a bottom-up model is proposed to estimate residential energy demand using datasets that are commonly available in the United States. The model applies novel machine learning methods to match records in the Residential Energy Consumption Survey with Public Use Microdata samples. This matching and machine learning produce a synthetic household energy distribution at a neighborhood scale. The model was tested and validated with data from the Atlanta metropolitan region to demonstrate its application and promise.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Energy, economic, and environmental analysis of integration of thermal energy storage into district heating systems using waste heat from data centres

Data centres produce waste heat, which can be utilized in district heating systems. However, the mismatch between data centres’ heat supply and district heating systems’ heat demands limits its utilization. Further, high peak loads increase the operation cost of district heating systems. This study aimed to solve these problems by introducing thermal energy storages. A water tank and a borehole thermal energy storage system were selected as the short-term and long-term thermal energy storage, respectively. Energy, economic, and environmental indicators were introduced to evaluate different solutions. The case study was a campus district heating system in Norway. Results showed that the water tank could shave the peak load by 31% and save the annual energy cost by 5%. The payback period was lower than 15 years when the storage efficiency remained higher than 80%. However, it had no obvious benefits in terms of mismatch relieving and CO emissions reduction. In contrast, the borehole thermal energy storage increased the waste heat utilization rate to 96% and reduced the annual CO emissions by 8%. However, the payback period was more than 17 years. These results provide guidelines for the retrofit of district heating systems, where data centres’ waste heat is available.

25 ENERGY STORAGE↗

Building thermal dynamics modeling with deep transfer learning using a large residential smart thermostat dataset

Understanding thermal dynamics and obtaining the computational model of residential buildings enable its scaled application in energy retrofits, control optimization and decarbonization. In this paper, we present a deep learning approach to model building thermal dynamics with smart thermostat data collected from residential buildings, with the goal to investigate model generalizability. In the first stage, we developed and compared different Deep Learning architectures including Convolutional Neural Networks (CNN), Long Short-Term Memory (LSTM) models and CNN-LSTM to predict indoor air temperature in a multi-step time horizon. In the second stage, we implemented a Transfer Learning (TL) process, which aims to improve the prediction performance on a new set of buildings (targets), exploiting the knowledge of related or similar buildings (sources). Different TL strategies and source model identification methods were investigated. The study showed that the CNN-LSTM performed the best among the architectures compared, with an average Mean Absolute Error (MAE) of 0.26 °C for one-hour-ahead (twelve 5-min future steps) predictions. Furthermore, the results showed that freezing the LSTM layer and fine-tuning the other layers of the CNN-LSTM achieved the best performance among four TL strategies, which further improved the performance with respect to a machine learning approach by 10%, and proving the effectiveness and generalizability of the proposed approach. A comparison of three different source model identification methods showed that randomly selecting source models constrained by similar building characteristics can provide good TL performance while retaining simplicity comparing with other quantitative source identification methods.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

U.S. Energy Service Company Industry: Market Size and Project Performance from 1990-2008

The U.S. energy service company (ESCO) industry is an example of a private sector business model where energy savings are delivered to customers primarily through the use of performance-based contracts. This study was conceived as a snapshot of the ESCO industry prior to the economic slowdown and the introduction of federal stimulus funding mandated by enactment of the American Recovery and Reinvestment Act of 2009 (ARRA). This study utilizes two parallel analytic approaches to characterize ESCO industry and market trends in the U.S.: (1) a ?top-down? approach involving a survey of individual ESCOs to estimate aggregate industry activity and (2) a ?bottom-up? analysis of a database of ~;;3,250 projects (representing over $8B in project investment) that reports market trends including installed EE retrofit strategies, project installation costs and savings, project payback times, and benefit-cost ratios over time. Despite the onset of a severe economic recession, the U.S. ESCO industry managed to grow at about 7percent per year between 2006 and 2008. ESCO industry revenues were about $4.1 billion in 2008 and ESCOs anticipate accelerated growth through 2011 (25percent per year). We found that 2,484 ESCO projects in our database generated ~;;$4.0 billion ($2009) in net, direct economic benefits to their customers. We estimate that the ESCO project database includes about 20percent of all U.S. ESCO market activity from 1990-2008. Assuming the net benefits per project are comparable for ESCO projects that are not included in the LBNL database, this would suggest that the ESCO industry has generated ~;;$23 billion in net direct economic benefits for customers at projects installed between 1990 and 2008. There is empirical evidence confirming that the industry is evolving by installing more comprehensive and complex measures?including onsite generation and measures to address deferred maintenance?but this evolution has significant implications for customer project economics, especially at K-12 schools. We found that the median simple payback time has increased from 1.9 to 3.2 years in private sector projects since the early-to-mid 1990s and from 5.2 to 10.5 years in public sector projects for the same time period.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Computational analysis of flame initiation, quenching, and re-ignition in a prechamber natural gas engine under varying EGR-dilution levels

The on-road natural-gas (NG) fueled transportation relies on stoichiometric spark-ignition engines for the advantages of simple after-treatment system despite the efficiency penalty relative to lean-burn combustion strategies. Exhaust gas recirculation (EGR) has the potential to reduce this efficiency gap at low to moderate loads without the need for complex lean-exhaust aftertreatment systems. However, EGR dilution leads to reduced combustion stability and increased cycle-to-cycle variability. A promising technology that has the potential to achieve reliable operation under diluted conditions is the prechamber ignition (or turbulent jet ignition) which uses chemically active turbulent jets generated from combustion inside a prechamber to initiate, stabilize and accelerate combustion of the mixture inside the main chamber. The present work focusses on developing a RANS-based CFD approach to accurately reproduce in-cylinder phenomena in a stoichiometric NG prechamber-assisted heavy-duty engine without relying on complex combustion models that account for turbulence-chemistry interactions. This is necessary because reactive prechamber jets at high EGR dilution tend to extinguish while emerging into the main chamber, which is followed by a phase of re-ignition — a phenomenon that conventional G-equation or well-stirred reactor combustion models cannot reproduce. With addition of a damping multiplier to the well-stirred reactor model, the predictions are seen to show good agreement with experimental pressure evolution and combustion images acquired from a single cylinder Cummins N-14 optical diesel engine retrofitted with a prechamber ignition system. Model predictions of local heat release in the flame and temperature evolution inside the flame are used to investigate combustion dynamics in the prechamber and the main chamber. It is seen that the well-stirred reactor model with the inclusion of damping is able to reproduce the temporary reduction in heat release within the flame, which can be considered equivalent to quenching of jets, and the subsequent re-ignition of the flame inside the main chamber. The delay between quenching and re-ignition depends on the amount of dilution, as explained by an illustration of flame evolution in a Borghi diagram.

Prechamber ignition↗

Limiter-aware adaptive excitation control for hydropower generators with legacy voltage regulation systems

Hydropower units often rely on legacy excitation systems with fixed automatic voltage regulator (AVR) settings, but parameter drift, changing operating conditions, and evolving grid-service demands can degrade terminal-voltage regulation over time. This problem should be addressed because poor voltage regulation affects reactive-power support, system stability, and reliable plant operation, and replacing installed AVR and limiter logic is costly and disruptive in practice. To address this issue, this paper proposes a retrofit-friendly enhancement for hydropower generator excitation systems that combines adaptive tuning of the AVR middle lead–lag branch with a small proportional-integral correction for removing steady bias and slow drift. The adaptive laws are normalized, projection-bounded, and equipped with leakage, while adaptation is enabled only in the middle branch. Thus, the intent of the underexcitation and overexcitation limiters, as well as legacy current and rate limits, remains unchanged. Stability is analyzed under incremental performance assumptions, yielding boundedness and asymptotic tracking in the absence of saturation. The method is evaluated using real operational data from a utility-scale hydropower unit at Rocky Reach Dam, Unit C-8. Compared with the fixed AVR baseline, the proposed method reduces terminal-voltage mean squared error by about 70%, removes long periods of steady-state bias, and improves transient tracking while coexisting with limiter actions. These results show that substantial voltage-control improvement can be achieved on existing hydropower units with minimal integration effort and without replacing the installed AVR structure.

ESST5B model↗

Assessment of oil and gas fields in California as potential CO 2 storage sites

California's total annual greenhouse gas (GHG) emissions (425.3 MtCO 2 e) in 2018 were about 6.4% of the US total (6,677 MtCO 2 e) and around 1% of global emissions. About 39% of 2018 GHG emissions in California were from the industrial and electrical sectors. Many of these emissions were from large stationary point sources and were suitable for carbon capture retrofit with subsequent storage of the captured carbon dioxide (CO 2 ) in geological formations. Previous studies of California found suitable geology and CO 2 storage resource. This study refines and furthers prior work using a three-stage screening process of oil fields, gas fields, and underground natural gas storage (UGS) sites by combining criteria from previous studies while excluding sites that pose technical risk or are located in regions with surface restrictions including sensitive habitats and dense populations. In the first stage, 129 CO 2 storage sites in California were identified using qualification criteria based upon formation properties including geological conditions and pore pressure. The second stage identified sensitive sites by applying conservative screens including seismic activity, faulting, population density, restricted lands, and sensitive habitats. During the third stage, 61 CO 2 potential storage sites were identified by subtraction of stage 2 areas from stage 1. The potential storage volume in the third stage ranged from 1.0 to 2.0 GtCO 2 . Finally, we applied a scoring system with seven parameters to rank the 61 potential sites based on subsurface technical criteria. The scored sites are classified as high priority, medium priority, and sites for future study. Prospective CO 2 storage sites with high and moderate priority were selected and linked to CO 2 sources. There are 14 prospective sites (above 20 MtCO 2 storage resource per site) with a total storage resource of 1024 MtCO 2 distributed in Northern and Southern California. Of these sites, there are 9 potential CO 2 -EOR sites and 1 depleted oil field with a total estimated CO 2 storage volume of ~800 MtCO 2 in the Southern San Joaquin and Ventura Basin. These 10 prospective sites with a storage resource greater than 20 MtCO 2 could potentially deliver more than 20 years of storage with an average injection rate of 40 MtCO 2 /year. The remaining 4 highly prospective sites are in Northern California. Additionally, study results suggest that saline formations should be re-evaluated in concert with storage in oil, gas, and natural gas storage reservoirs.

58 GEOSCIENCES↗

Personal power using metal-supported solid oxide fuel cells operated in a camping stove flame

A complete stand-alone product prototype providing combined cooking and power is fabricated by retrofitting a commercial camping stove with a stack of metal-supported solid oxide fuel cells (MS-SOFCs) delivering power to microelectronic LED driver and voltage boost circuits. The 5-cell stack produces 2.7 W (156 mW cm -2 ) while cooking on the stove, and is demonstrated to produce LED lighting and mobile phone charging while operating outdoors. Cooking efficiency is minimally impacted by the presence of the MS-SOFCs. As a result, it is found that vertical orientation of the cells is critical to maintain separation of fuel and air when a pot is placed on the stove.

25 ENERGY STORAGE↗

Risk assessment and ventilation modeling for hydrogen releases in vehicle repair garages

The availability of repair garage infrastructure for hydrogen fuel cell vehicles is becoming increasingly important for future industry growth. Ventilation requirements for hydrogen fuel cell vehicles can affect both retrofitted and purpose-built repair garages and the costs associated with these requirements can be significant. A hazard and operability (HAZOP) study was performed to identify risk-significant scenarios related to light-duty hydrogen vehicles in a repair garage. Detailed simulations and modeling were performed using appropriate computational tools to estimate the location, behavior, and severity of hydrogen release based on key HAZOP scenarios. Here, this work compares current fire code requirements to an alternate ventilation strategy to further reduce potential hazardous conditions. Modeling shows that position, direction, and velocity of ventilation have a significant impact on the amount of instantaneous flammable mass in the domain.

08 HYDROGEN↗

COVID 19 vaccine distribution solution to the last mile challenge: Experimental and simulation studies of ultra-low temperature refrigeration system

Most COVID-19 vaccines require ambient temperature control for transportation and storage. Both Pfizer and Moderna vaccines are based on mRNA and lipid nanoparticles requiring low temperature storage. The Pfizer vaccine requires ultra-low temperature storage (between -80 °C and -60 °C), while the Moderna vaccine requires -30 °C storage. Pfizer has designed a reusable package for transportation and storage that can keep the vaccine at the target temperature for 10 days. However, the last stage of distribution is quite challenging, especially for rural or suburban areas, where local towns, pharmacy chains and hospitals may not have the infrastructure required to store the vaccine. Also, the need for a large amount of ultra-low temperature refrigeration equipment in a short time period creates tremendous pressure on the equipment suppliers. In addition, there is limited data available to address ancillary challenges of the distribution framework for both transportation and storage stages. As such, there is a need for a quick, effective, secure, and safe solution to mitigate the challenges faced by vaccine distribution logistics. The study proposes an effective, secure, and safe ultra-low temperature refrigeration solution to resolve the vaccine distribution last mile challenge. Furthermore, the approach is to utilize commercially available products, such as refrigeration container units, and retrofit them to meet the vaccine storage temperature requirement. Both experimental and simulation studies are conducted to evaluate the technical merits of this solution with the ability to control temperature at -30 °C or -70 °C as part of the last mile supply chain for vaccine candidates.

60 APPLIED LIFE SCIENCES↗

Carbon neutral manufacturing via on-site CO 2 recycling

The chemical industry needs to significantly decrease carbon dioxide (CO 2 ) emissions in order to meet the 2050 carbon neutrality goal. Utilization of CO 2 as a chemical feedstock for bulk products is a promising way to mitigate industrial emissions; however, CO 2 -based manufacturing is currently not competitive with the established petrochemical methods and its deployment requires creation of a new value chain. Here, we show that an alternative approach, using CO 2 conversion as an add-on to existing manufactures, can disrupt the global carbon cycle while minimally perturbing the operation of chemical plants. Proposed closed-loop on-site CO 2 recycling processes are economically viable in the current market and have the potential for rapid introduction in the industries. Retrofit-based CO 2 recycling can reduce annually between 4 and 10 Gt CO 2 by 2050 and contribute to achieving up to 50% of the industrial carbon neutrality goal.

30 DIRECT ENERGY CONVERSION↗

Large balancing areas and dispersed renewable investment enhance grid flexibility in a renewable-dominant power system in China

Renewable energy is poised to play a major role in achieving China's carbon neutrality goal by 2060; however, reliability and flexibility is a big concern of a renewable-dominant power system. Various strategies of enhancing flexibility are under discussion to ensure the reliability of such a system, but no detailed quantitative analysis has been reported yet in China. We combine the advantages of a capacity expansion model, SWITCH-China, with a production simulation model, PLEXOS, and analyze flexibility options under different scenarios of a renewable-dominant power system in China. We find that a larger balancing area offers direct flexibility benefits. Regional balancing could reduce the renewable curtailment rate by 5-7%, compared with a provincial balancing strategy. National balancing could further reduce the power cost by about 16%. However, retrofitting coal power plants for flexible operation would only improve the system flexibility marginally.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Model-based economic analysis under uncertainty for PFAS treatment by granular activated carbon and ion exchange technologies

Recent drinking water regulations have imposed the need for per- and polyfluoroalkyl substances (PFAS) remediation. In response, treatment facilities may be required to retrofit existing treatment schemes to treat PFAS below maximum contaminant levels (MCLs). Adsorption technologies such as granular activated carbon (GAC) and ion exchange (IX) have been demonstrated to be effective; however, there are limited techno-economic metrics available which provide guidance on technology selection and design for diverse PFAS-containing source water conditions. Process systems engineering (PSE) tools which can traditionally perform these analyses are hindered by the data availability, model validity, and understanding of treatment phenomena for emerging contaminants. This work employs published data regressions, statistical models, process models, techno-economic analyses, and other process systems tools in a model-based uncertainty framework to consider the limitations of emerging contaminant research. Through this analysis framework, economic results are provided as probabilistic distributions based on the uncertainty of the models and diverse conditions that treatment facilities experience.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Potential impact of work from home jobs on residential energy bills: A case study in phoenix, AZ, USA

Nearly one-third of U.S. households face challenges paying energy bills. During the day, many residents have routine access to cooled environments provided by others—employers, shopping centers, and other public buildings. The COVID-19 pandemic, however, has significantly shifted the cost burden of air conditioning in hot cities. Specifically, during the pandemic, many companies either laid off employees or put them in work-from-home (WFH) assignments. Large tech companies are already promoting WFH as a long-term option for their employees, even after the pandemic. This change in the nature of the workforce might reduce daily travel expenses for workers, but could also significantly increase residential energy bills, particularly during summer in very hot climates. Here, this study uses building energy simulations to quantify the potential residential energy bill penalties resulting from WFH for typical residences in Phoenix. Four building archetypes are used in this study to represent variations in building vintage, occupancy, and characteristics. The results show that, for some single-family residences in Phoenix, WFH can increase annual energy bills by more than $1100 (up to a 70% increase). The study also demonstrates that building performance enhancement retrofit measures have the potential to reduce this WFH energy bill penalty for the existing buildings substantially.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Characterizing electrical panel capacity, breaker space, and loads in U.S. single-family homes

Electrical panels distribute electricity to appliances, equipment, and other building loads and maintain safety by preventing overloads of branch circuits, feeders, and utility service wires connecting homes to the grid. Load calculations in the National Electrical Code (NEC) determine the capacity of installed electrical panels in the United States, which are rated in amps (A). Circuit breakers within electrical panels affect the magnitude and number of loads that panels can serve. In home retrofits and renovations, existing electrical panels may not accommodate new electrical loads, either due to insufficient electrical capacity or a lack of available breaker spaces. Homes with these panel constraints may need to replace existing panels with new panels that have greater capacity and breaker space.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Stabilizing dynamic subsea power cables using Bi-stable nonlinear energy sinks

This study investigates vibration mitigation of dynamic subsea cables through passive bi-stable nonlinear energy sinks (B-NESs). These devices suppress vibration energy in a broadband way, and can be regarded as extensions of classical linear tuned mass dampers (TMDs) which are narrowband devices. Through the open-source MoorDyn library, we simulated the vibrations of a vertical subsea cable equipped with a set of B-NESs. Multi-objective optimization was performed to detect the B-NES parameters for optimal mitigation of the cable vibrations. Advanced signal processing verified the efficacy of the optimized B-NESs not only to rapidly absorb and locally dissipate vibration energy, but also to nonlinearly scatter vibration energy from low to high frequencies within the cable itself. This last feature is especially beneficial for vibration mitigation of the undersea cable, as at higher frequencies the cable vibrations exhibit drastically reduced amplitudes and are more effectively dissipated by inherent structural damping and hydrodynamic radiation damping. This contrasts with traditional TMDs which can mitigate vibration only at a single frequency. Furthermore, our robustness study confirms the B-NES's effectiveness under even varying environmental conditions. Overall, the B-NES's capacity for broadband vibration mitigation renders it a promising retrofit solution for improving the performance and operational safety of dynamic power cables in offshore wind farms and other marine applications.

17 WIND ENERGY↗