Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Radiation Sources”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,351 records · Page 75

Neutronics Evaluation of the Preliminary Design of the Service Cell Door for the Second Target Station

The service cell door needs to provide sufficient shielding to achieve 0.25 mrem/h dose rates in the adjacent room while remote handling operations of waste materials are going on within the service cell for the Second Target Station (STS). This analysis provides a neutronics evaluation of the preliminary design of the service cell door to evaluate the required thickness and the effect of streaming gaps around the door. As radiation source, we use the decay gamma source of the moderator reflector assembly (MRA) of the STS with a decay time of either two days or six months. As the MRA contains a significant amount of beryllium, photonuclear reactions induce a neutron source, which dictates the required door thickness in certain situations. Four scenarios with different MRA positions and decay times have been analyzed. The required thickness differs drastically depending on the chosen scenario and on the material of the door. The streaming through the gaps around the door is relatively small with high dose rates limited to small sections of the geometry.

43 PARTICLE ACCELERATORS↗

Choosing Transport Events for Initiating Splitting and Rouletting

A study was performed to determine which transport events should be used to initiate a weight window lookup to achieve the best variance reduction performance. A weight window lookup potentially triggers particle splitting (in important regions of phase space) or rouletting (in unimportant regions), thereby optimizing computational effort. Potential initiating transport events include collisions (both pre- and post-collision), geometry surface crossings, traversing a mean-free path, and streaming across a weight window boundary. Permutations of these initiating events were tested on an urban model with background radiation sources and a spent fuel cask with a neutron dose mesh tally. Generally, all methods perform better with finer weight window meshes. Tracking on weight windows performs well for coarse weight window meshes, while a combination of splitting each mean-free path, geometric surface crossing, and before collisions performs well for fine weight window meshes.

42 ENGINEERING↗

Harnessing Ultra-Intense Long-Wave Infrared Lasers: New Frontiers in Fundamental and Applied Research

This review explores two main topics: the state-of-the-art and emerging capabilities of high-peak-power, ultrafast (picosecond and femtosecond) long-wave infrared (LWIR) laser technology based on CO2 gas laser amplifiers, and the current and advanced scientific applications of this laser class. The discussion is grounded in expertise gained at the Accelerator Test Facility (ATF) of Brookhaven National Laboratory (BNL), a leading center for ultrafast, high-power CO2 laser development and a National User Facility with a strong track record in high-intensity physics experiments. We begin by reviewing the status of 9–10 μm CO2 laser technology and its applications, before exploring potential breakthroughs, including the realization of 100 terawatt femtosecond pulses. These advancements will drive ongoing research in electron and ion acceleration in plasma, along with applications in secondary radiation sources and atmospheric energy transport. Throughout the review, we highlight how wavelength scaling of physical effects enhances the capabilities of ultra-intense lasers in the LWIR spectrum, expanding the frontiers of both fundamental and applied science.

43 PARTICLE ACCELERATORS↗

ALMA Multiple-transition Molecular Line Observations of the Ultraluminous Infrared Galaxy IRAS 20551–4250: Different HCN, HCO{sup +}, and HNC Excitation, and Implications for Infrared Radiative Pumping

We present our ALMA multi-transition molecular line observational results for the ultraluminous infrared galaxy IRAS 20551−4250, which is known to contain a luminous buried active galactic nucleus and shows detectable vibrationally excited (v {sub 2} = 1f) HCN and HNC emission lines. The rotational J = 1–0, 4–3, and 8–7 of HCN, HCO{sup +}, and HNC emission lines were clearly detected at a vibrational ground level (v = 0). Vibrationally excited (v {sub 2} = 1f) J = 4–3 emission lines were detected for HCN and HNC, but not for HCO{sup +}. Their observed flux ratios further support our previously obtained suggestion, based on J = 3–2 data, that (1) infrared radiative pumping plays a role in rotational excitation at v = 0, at least for HCN and HNC, and (2) HCN abundance is higher than HCO{sup +} and HNC. The flux measurements of the isotopologue H{sup 13}CN, H{sup 13}CO{sup +}, and HN{sup 13}C J = 3–2 emission lines support the higher HCN abundance scenario. Based on modeling with collisional excitation, we constrain the physical properties of these line-emitting molecular gases, but find that higher HNC rotational excitation than HCN and HCO{sup +} is difficult to explain, due to the higher effective critical density of HNC. We consider the effects of infrared radiative pumping using the available 5–30 μm infrared spectrum and find that our observational results are well-explained if the radiation source is located at 30–100 pc from the molecular gas. The simultaneously covered very bright CO J = 3–2 emission line displays a broad emission wing, which we interpret as being due to molecular outflow activity with the estimated rate of ∼150 M{sub ⊙} yr{sup −1}.

79 ASTRONOMY AND ASTROPHYSICS↗

Adiabatic and Radiative Cooling of Relativistic Electrons Applied to Synchrotron Spectra and Light Curves of Gamma-Ray Burst Pulses

We investigate the adiabatic and radiative (synchrotron and inverse-Compton) cooling of relativistic electrons whose injected or initial distribution with energy is a power law. Herein, analytical and numerical results are presented for the cooling-tail and the cooled-injected distribution that develop below and above the typical energy of injected electrons, for the evolution of the peak energy E p of the synchrotron emission spectrum. The pulse shape resulting from an episode of electron injection is also analyzed. The synchrotron emission calculated numerically is compared with the spectrum and shape of Gamma-ray burst (GRB) pulses. Both adiabatic and radiative cooling processes lead to a softening of the pulse spectrum, and both types of cooling processes lead to pulses peaking earlier and lasting shorter at higher energy, quantitatively consistent with observations. For adiabatic-dominated electron cooling, a power-law injection rate R i suffices to explain the observed power-law GRB low-energy spectra. Synchrotron-dominated cooling leads to power-law cooling-tails that yield the synchrotron standard slope α = –3/2 provided that R i ~ B 2 , which is exactly the expectation if the magnetic field is a constant fraction of the post-shock energy density. Increasing (decreasing) R i and decreasing (increasing) B ( t ) lead to harder (softer, respectively) slopes α than the standard value and to nonpower-law (curved) cooling-tails. Inverse-Compton cooling yields four values for the slope α but, as for synchrotron, other R i or B histories yield a wider range of slopes and curved low-energy spectra. Feedback between the power-law segments that develop below and above the typical injected electron leads to a synchrotron spectrum with many breaks.

79 ASTRONOMY AND ASTROPHYSICS↗

Charging, aggregation, and electrostatic dispersion of radioactive and nonradioactive particles in the atmosphere

Electrostatic dispersion can significantly impact the microphysical behavior of charged particles and ions until reaching zero space charge. However, although radioactive particles can be strongly charged in air, the influence of electrostatic dispersion has been neglected in understanding their behavior. This study is aimed at investigating the time evolution of the charge and size distributions of radioactive and nonradioactive particles in air and developing simple approaches for applications. With processes involving charging, aggregation, and electrostatic dispersion, a comprehensive population balance model (PBM) has been developed to examine particle charge/size distribution dynamics. It is shown that compared to nonradioactive particles, the charge and size distributions of radioactive particles may evolve differently with time because radioactivity and electrostatic dispersion can significantly affect the charging and aggregation kinetics of the particles. It is found that, after the Fukushima accident, background aerosols in the pathway of radioactive plumes might be highly charged due to ionizing radiation, suggesting that radiation fields may strongly influence in situ measurements of charged atmospheric particles. The comprehensive PBM is simplified, and then the verification and application of the simplified PBMs are discussed. This study provides useful insight into how radioactivity can affect the dynamic behavior of particles in atmospheric systems including radiation sources.

54 ENVIRONMENTAL SCIENCES↗

ARM Airborne Continuous carbon dioxide measurements

The heart of the AOS CO2 Airborne Rack Mounted Analyzer System is the AOS Manifold. The AOS Manifold is a nickel coated aluminum analyzer and gas processor designed around two identical nickel-plated gas cells, one for reference gas and one for sample gas. The sample and reference cells are uniquely designed to provide optimal flushing efficiency. These cells are situated between a black-body radiation source and a photo-diode detection system. The AOS manifold also houses flow meters, pressure sensors and control valves. The exhaust from the analyzer flows into a buffer volume which allows for precise pressure control of the analyzer. The final piece of the analyzer is the demodulator board which is used to convert the DC signal generated by the analyzer into an AC response. The resulting output from the demodulator board is an averaged count of CO2 over a specified hertz cycle reported in volts and a corresponding temperature reading. The system computer is responsible for the input of commands and therefore works to control the unit functions such as flow rate, pressure, and valve control.The remainder of the system consists of compressors, reference gases, air drier, electrical cables, and the necessary connecting plumbing to provide a dry sample air stream and reference air streams to the AOS manifold.

54 ENVIRONMENTAL SCIENCES↗

ARM Airborne Continuous carbon dioxide measurements

The heart of the AOS CO2 Airborne Rack Mounted Analyzer System is the AOS Manifold. The AOS Manifold is a nickel coated aluminum analyzer and gas processor designed around two identical nickel-plated gas cells, one for reference gas and one for sample gas. The sample and reference cells are uniquely designed to provide optimal flushing efficiency. These cells are situated between a black-body radiation source and a photo-diode detection system. The AOS manifold also houses flow meters, pressure sensors and control valves. The exhaust from the analyzer flows into a buffer volume which allows for precise pressure control of the analyzer. The final piece of the analyzer is the demodulator board which is used to convert the DC signal generated by the analyzer into an AC response. The resulting output from the demodulator board is an averaged count of CO2 over a specified hertz cycle reported in volts and a corresponding temperature reading. The system computer is responsible for the input of commands and therefore works to control the unit functions such as flow rate, pressure, and valve control.The remainder of the system consists of compressors, reference gases, air drier, electrical cables, and the necessary connecting plumbing to provide a dry sample air stream and reference air streams to the AOS manifold.

54 ENVIRONMENTAL SCIENCES↗

Densitometer system for liquid hydrogen has high accuracy, fast response

Developmental densitometer system for cryogenic liquids uses two balanced ionization chambers containing xenon gas, with X rays as the radiation source. The X rays are heavily filtered with a lead shield to make the energy spectrum much less dependent on the voltage applied to the X ray tube.

Source record↗

Solar simulation research

Improved measurement techniques for solar simulators, support equipment, and solar cells - pressure arc chamber and vortex stabilized radiation source - radiometry

ARC CHAMBER↗