Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “RESOLUTION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,351 records · Page 75

Effect of sintering temperature on feature resolution and flexural strength of ceramics fabricated through vat photopolymerization additive manufacturing

Although ceramic additive manufacturing (AM) could be used to fabricate complex, high-resolution parts for diverse, functional applications, one ongoing challenge is optimizing the post-process, particularly sintering, conditions to consistently produce geometrically accurate and mechanically robust parts. This study aims to investigate how sintering temperature affects feature resolution and flexural properties of silica-based parts formed by vat photopolymerization (VPP) AM. Test artifacts were designed to evaluate features of different sizes, shapes and orientations, and three-point bend specimens printed in multiple orientations were used to evaluate mechanical properties. Sintering temperatures were varied between 1000°C and 1300°C. Deviations from designed dimensions often increased with higher sintering temperatures and/or larger features. Higher sintering temperatures yielded parts with higher strength and lower strain at break. Many features exhibited defects, often dependent on geometry and sintering temperature, highlighting the need for further analysis of debinding and sintering parameters. To the best of the authors’ knowledge, this is the first time test artifacts have been designed for ceramic VPP. This work also offers insights into the effect of sintering temperature and print orientation on flexural properties. These results provide design guidelines for a particular material, while the methodology outlined for assessing feature resolution and flexural strength is broadly applicable to other ceramics, enabling more predictable part performance when considering the future design and manufacture of complex ceramic parts.

36 MATERIALS SCIENCE↗

Distributed Fiber Sensors With High Spatial Resolution in Extreme Radiation Environments in Nuclear Reactor Cores

This paper is a comprehensive experimental report on the neutron radiation effects of distributed optical fiber sensors with enhanced Rayleigh scattering profiles in an in-pile environment. Femtosecond laser direct writing was used to inscribe Type-II modifications in standard telecom fibers and radiation-hardened fibers with fluorine-doped cores. Rayleigh backscattering signals were enhanced for continuous 1.5 m. In-pile lead-out sensors tests were carried out at the MIT Research Reactor for two months, which was operated at a nominal power of 5.7 MW with fast neutron (>0.1 MeV) flux of 1.29 × 1014 n/cm2/s and an in-core temperature of up to 560°C. Using the Optical Frequency Domain Reflectometry technique, the backscattering profiles of fiber sensors were interrogated with a 3-cm spatial resolution to monitor the temperature profile of the reactor. Results show that laser inscribed Type-II modifications in the form of nanogratings are highly stable against extreme temperature and ionizing radiation. Both standard telecom fibers and radiation-hardened fibers with laser-enhanced Rayleigh profiles can continuously perform distributed temperature measurements over the entire duration of the in-pile testing. Temperature coefficients of sensors and spectral shift quality were studied as functions of total radiation fluence. To the best of our knowledge, we present for the first time, the temperature profile of an operating nuclear reactor core with 3-cm spatial resolution, enabled by distributed fiber sensors with laser-enhanced Rayleigh scattering profiles. The high spatial resolution measurements can provide valuable data for the design and validation of digital twin and virtual reality of nuclear energy systems.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Fine Tuning of Mach-Zehnder Phase Using Low-Resolution Digital-to-Analog Converters

We present a novel approach for achieving fine phase-tuning control of a Mach-Zehnder interferometer-based photonic switch. We demonstrate the concept in a fabricated silicon photonic switch containing dual thermo-optic phase tuners driven from identical monolithically integrated low-resolution digital-to-analog converters. The delivered resolution gains and additional power overheads of the demonstrated approach are assessed through experimental measurements. Using the approach, we show a resolution improvement of more than a factor of seven with only a 1.7% increase in power dissipation.

42 ENGINEERING↗

Direct Modeling of Scintillator Thickness for Optimal Light Output and Spatial Resolution

It is common in x-ray radiography to use scintillators (e.g., BGO or LSO) to convert x-rays to visible light, which is then recorded by an imaging system. The response of the scintillator depends fundamentally on its thickness, with respect to both its visible light emittance and its spatial resolution. This is important for optimizing light output, signal to noise ratio, or optical response time. Given that it is often cost-prohibitive to procure a variety of scintillator samples and empirically test the performance, it is essential to be able to model and accurately simulate the performance of a scintillator with respect to thickness and other properties, and a direct way of doing this is using Monte Carlo-based radiation transport codes. Such simulations can be expensive in terms of computational time, and the codes are not easily obtained. In this work we first show such simulations, and demonstrate that there is a natural trade-off between light output of a scintillator and its spatial resolution. We then derive a first-principles model that accurately approximates the light output, using straightforward calculations that can be performed quickly with any basic computing software. We compare the results to those obtained from Monte Carlo simulations and show that our simplified model can be used to analyze the tradeoff between emittance and resolution nearly as well as using a full-scale radiation transport code.

Monte Carlo methods, X-ray imaging, scintillation ↗

Efficient and Flexible Hierarchical Data Layouts for a Unified Encoding of Scalar Field Precision and Resolution

To address the problem of ever-growing scientific data sizes making data movement a major hindrance to analysis, we introduce a novel encoding for scalar fields: a unified tree of resolution and precision, specifically constructed so that valid cuts correspond to sensible approximations of the original field in the precision-resolution space. Furthermore, we introduce a highly flexible encoding of such trees that forms a parameterized family of data hierarchies. We discuss how different parameter choices lead to different trade-offs in practice, and show how specific choices result in known data representation schemes such as zfp[52], idx[58], and jpeg2000 [76]. Lastly, we provide system-level details and empirical evidence on how such hierarchies facilitate common approximate queries with minimal data movement and time, using real-world data sets ranging from a few gigabytes to nearly a terabyte in size. Experiments suggest that our new strategy of combining reductions in resolution and precision is competitive with state-of-the-art compression techniques with respect to data quality, while being significantly more flexible and orders of magnitude faster, and requiring significantly reduced resources.

97 MATHEMATICS AND COMPUTING↗

F-Hash: Feature-Based Hash Design for Time-Varying Volume Visualization via Multi-Resolution Tesseract Encoding

Interactive time-varying volume visualization is challenging due to its complex spatiotemporal features and sheer size of the dataset. Recent works transform the original discrete time-varying volumetric data into continuous Implicit Neural Representations (INR) to address the issues of compression, rendering, and super-resolution in both spatial and temporal domains. However, training the INR takes a long time to converge, especially when handling large-scale time-varying volumetric datasets. In this work, we proposed F-Hash, a novel feature-based multi-resolution Tesseract encoding architecture to greatly enhance the convergence speed compared with existing input encoding methods for modeling time-varying volumetric data. The proposed design incorporates multi-level collision-free hash functions that map dynamic 4D multi-resolution embedding grids without bucket waste, achieving high encoding capacity with compact encoding parameters. Our encoding method is agnostic to time-varying feature detection methods, making it a unified encoding solution for feature tracking and evolution visualization. Experiments show the F-Hash achieves state-of-the-art convergence speed in training various time-varying volumetric datasets for diverse features. We also proposed an adaptive ray marching algorithm to optimize the sample streaming for faster rendering of the time-varying neural representation.

deep learning↗

Mechanisms of proton relay and product release by Class A β-lactamase at ultrahigh resolution

The beta-lactam antibiotics inhibit penicillin-binding proteins (PBPs) by forming a stable, covalent, acyl-enzyme complex. During the evolution from PBPs to Class A beta-lactamases, the beta-lactamases acquired Glu166 to activate a catalytic water and cleave the acyl-enzyme bond. Here we present three product complex crystal structures of CTX-M-14 Class A beta-lactamase with a ruthenocene-conjugated penicillin-a 0.85 angstrom resolution structure of E166A mutant complexed with the penilloate product, a 1.30 angstrom resolution complex structure of the same mutant with the penicilloate product, and a 1.18 angstrom resolution complex structure of S70G mutant with a penicilloate product epimer-shedding light on the catalytic mechanisms and product inhibition of PBPs and Class A beta-lactamases. The E166A-penilloate complex captured the hydrogen bonding network following the protonation of the leaving group and, for the first time, unambiguously show that the ring nitrogen donates a proton to Ser130, which in turn donates a proton to Lys73. These observations indicate that in the absence of Glu166, the equivalent lysine would be neutral in PBPs and therefore capable of serving as the general base to activate the catalytic serine. Together with previous results, this structure suggests a common proton relay network shared by Class A beta-lactamases and PBPs, from the catalytic serine to the lysine, and ultimately to the ring nitrogen. Additionally, the E166A-penicilloate complex reveals previously unseen conformational changes of key catalytic residues during the release of the product, and is the first structure to capture the hydrolyzed product in the presence of an unmutated catalytic serine.

59 BASIC BIOLOGICAL SCIENCES↗

High‐Resolution Direct Push NMR Tools for Groundwater Investigations

Abstract A small‐diameter nuclear magnetic resonance (NMR) technology optimized for use with direct push (DP) and cone penetrometer test (CPT) drilling has been developed. The DP NMR tool can be deployed through 2.25‐in. diameter DP and CPT drilling rods allowing high‐resolution NMR logging measurements to be acquired during retraction of drill rods. DP NMR technology runs from a person‐portable battery‐powered control unit and provides significantly higher resolution in both the spatial (vertical) dimension and in the time domain of the NMR measurement than previously available NMR technology. In this study, we summarize the development of two different DP NMR tools and demonstrate their application at different sites within the United States. We believe that this technology can provide a leap forward in adoption of NMR technology for high‐resolution hydrological and geophysical investigations in groundwater resources and environmental remediation applications.

54 ENVIRONMENTAL SCIENCES↗

High spatial resolution mass spectrometry imaging reveals the genetically programmed, developmental modification of the distribution of thylakoid membrane lipids among individual cells of maize leaf

Metabolism in plants is compartmentalized among different tissues, cells and subcellular organelles. Mass spectrometry imaging (MSI) with matrix-assisted laser desorption ionization (MALDI) has recently advanced to allow for the visualization of metabolites at single-cell resolution. Here we applied 5- and 10 μm high spatial resolution MALDI-MSI to the asymmetric Kranz anatomy of Zea mays (maize) leaves to study the differential localization of two major anionic lipids in thylakoid membranes, sulfoquinovosyldiacylglycerols (SQDG) and phosphatidylglycerols (PG). The quantification and localization of SQDG and PG molecular species, among mesophyll (M) and bundle sheath (BS) cells, are compared across the leaf developmental gradient from four maize genotypes (the inbreds B73 and Mo17, and the reciprocal hybrids B73 × Mo17 and Mo17 × B73). SQDG species are uniformly distributed in both photosynthetic cell types, regardless of leaf development or genotype; however, PG shows photosynthetic cell-specific differential localization depending on the genotype and the fatty acyl chain constituent. Overall, 16:1-containing PGs primarily contribute to the thylakoid membranes of M cells, whereas BS chloroplasts are mostly composed of 16:0-containing PGs. Furthermore, PG 32:0 shows genotype-specific differences in cellular distribution, with preferential localization in BS cells for B73, but more uniform distribution between BS and M cells in Mo17. Maternal inheritance is exhibited within the hybrids, such that the localization of PG 32:0 in B73 × Mo17 is similar to the distribution in the B73 parental inbred, whereas that of Mo17 × B73 resembles the Mo17 parent. As a result, this study demonstrates the power of MALDI-MSI to reveal unprecedented insights on metabolic outcomes in multicellular organisms at single-cell resolution.

59 BASIC BIOLOGICAL SCIENCES↗

High-resolution chemical patterns from negative tone resists for the integration of extreme ultraviolet patterns of metal-oxide resists with directed self-assembly of block copolymers

Extreme ultraviolet (EUV) lithography faces significant challenges in designing suitable resist materials that can provide adequate precision, while maintaining economically viable throughput. These challenges in resist materials have led to printing failures and high roughness in EUV patterns, compromising the performance of semiconductor devices. Integrating directed self-assembly (DSA) of block copolymers (BCPs) with EUV lithography offers a promising solution because, while the BCPs register to the EUV-defined chemical guiding pattern, the thermodynamically determined structures of the BCPs automatically rectify defects and roughness in the EUV pattern. Despite the superior resolution of metal-oxide EUV resists (MORs), their application to DSA is limited by the difficulty in converting them into chemical patterns that allow effective transfer of the rectified patterns of DSA films into inorganic materials. To address this challenge, this study introduces a novel strategy for fabricating chemical patterns using hydrogen silsesquioxane (HSQ), a high-resolution negative tone inorganic resist, as a model system for MORs. Initially, a sacrificial Cr pattern is generated from HSQ patterns via reactive ion etching. The sacrificial Cr pattern is converted into a chemical pattern by first grafting a water-soluble polyethylene oxide brush onto the substrate, then wet etching the Cr, and finally grafting nonpolar polystyrene brushes. Assembling polystyrene-block-poly(methyl methacrylate) on these patterns results in structures oriented and registered with the underlying pattern, achieving 24 nm full-pitch resolutions. In conclusion, this approach has the potential to integrate MOR patterns into the DSA process, thereby enabling the generation of high-quality sub-10 nm patterns with high-χ BCPs.

Atomic force microscopy↗

WE-F-16A-04: Micro-Irradiator Treatment Verification with High-Resolution 3D-Printed Rodent-Morphic Dosimeters

Purpose: Pre-clinical micro-radiation therapy studies often utilize very small beams (∼0.5-5mm), and require accurate dose delivery in order to effectively investigate treatment efficacy. Here we present a novel high-resolution absolute 3D dosimetry procedure, capable of ∼100-micron isotopic dosimetry in anatomically accurate rodent-morphic phantoms Methods: Anatomically accurate rat-shaped 3D dosimeters were made using 3D printing techniques from outer body contours and spinal contours outlined on CT. The dosimeters were made from a radiochromic plastic material PRESAGE, and incorporated high-Z PRESASGE inserts mimicking the spine. A simulated 180-degree spinal arc treatment was delivered through a 2 step process: (i) cone-beam-CT image-guided positioning was performed to precisely position the rat-dosimeter for treatment on the XRad225 small animal irradiator, then (ii) treatment was delivered with a simulated spine-treatment with a 180-degree arc with 20mm x 10mm cone at 225 kVp. Dose distribution was determined from the optical density change using a high-resolution in-house optical-CT system. Absolute dosimetry was enabled through calibration against a novel nano-particle scintillation detector positioned in a channel in the center of the distribution. Results: Sufficient contrast between regular PRESAGE (tissue equivalent) and high-Z PRESAGE (spinal insert) was observed to enable highly accurate image-guided alignment and targeting. The PRESAGE was found to have linear optical density (OD) change sensitivity with respect to dose (R{sup 2} = 0.9993). Absolute dose for 360-second irradiation at isocenter was found to be 9.21Gy when measured with OD change, and 9.4Gy with nano-particle detector- an agreement within 2%. The 3D dose distribution was measured at 500-micron resolution Conclusion: This work demonstrates for the first time, the feasibility of accurate absolute 3D dose measurement in anatomically accurate rat phantoms containing variable density PRESAGE material (tissue equivalent and bone equivalent). This method enables precise treatment verification of micro-radiation therapies, and enhances the robustness of tumor radio-response studies. This work was supported by NIH R01CA100835.

60 APPLIED LIFE SCIENCES↗

Characteristic image quality of a third generation dual-source MDCT scanner: Noise, resolution, and detectability

Purpose: The purpose of this work was to assess the inherent image quality characteristics of a new multidetector computed tomography system in terms of noise, resolution, and detectability index as a function of image acquisition and reconstruction for a range of clinically relevant settings. Methods: A multisized image quality phantom (37, 30, 23, 18.5, and 12 cm physical diameter) was imaged on a SOMATOM Force scanner (Siemens Medical Solutions) under variable dose, kVp, and tube current modulation settings. Images were reconstructed with filtered back projection (FBP) and with advanced modeled iterative reconstruction (ADMIRE) with iterative strengths of 3, 4, and 5. Image quality was assessed in terms of the noise power spectrum (NPS), task transfer function (TTF), and detectability index for a range of detection tasks (contrasts of approximately 45, 90, 300, −900, and 1000 HU, and 2–20 mm diameter) based on a non-prewhitening matched filter model observer with eye filter. Results: Image noise magnitude decreased with decreasing phantom size, increasing dose, and increasing ADMIRE strength, offering up to 64% noise reduction relative to FBP. Noise texture in terms of the NPS was similar between FBP and ADMIRE (<5% shift in peak frequency). The resolution, based on the TTF, improved with increased ADMIRE strength by an average of 15% in the TTF 50% frequency for ADMIRE-5. The detectability index increased with increasing dose and ADMIRE strength by an average of 55%, 90%, and 163% for ADMIRE 3, 4, and 5, respectively. Assessing the impact of mA modulation for a fixed average dose over the length of the phantom, detectability was up to 49% lower in smaller phantom sections and up to 26% higher in larger phantom sections for the modulated scan compared to a fixed tube current scan. Overall, the detectability exhibited less variability with phantom size for modulated scans compared to fixed tube current scans. Conclusions: Image quality increased with increasing dose and decreasing phantom size. The CT system exhibited nonlinear noise and resolution properties, especially at very low-doses, large phantom sizes, and for low-contrast objects. Objective image quality metrics generally increased with increasing dose and ADMIRE strength, and with decreasing phantom size. The ADMIRE algorithm could offer comparable image quality at reduced doses or improved image quality at the same dose. The use of tube current modulation resulted in more consistent image quality with changing phantom size.

60 APPLIED LIFE SCIENCES↗

High resolution 3D imaging of synchrotron generated microbeams

Purpose: Microbeam radiation therapy (MRT) techniques are under investigation at synchrotrons worldwide. Favourable outcomes from animal and cell culture studies have proven the efficacy of MRT. The aim of MRT researchers currently is to progress to human clinical trials in the near future. The purpose of this study was to demonstrate the high resolution and 3D imaging of synchrotron generated microbeams in PRESAGE® dosimeters using laser fluorescence confocal microscopy. Methods: Water equivalent PRESAGE® dosimeters were fabricated and irradiated with microbeams on the Imaging and Medical Beamline at the Australian Synchrotron. Microbeam arrays comprised of microbeams 25–50 μm wide with 200 or 400 μm peak-to-peak spacing were delivered as single, cross-fire, multidirectional, and interspersed arrays. Imaging of the dosimeters was performed using a NIKON A1 laser fluorescence confocal microscope. Results: The spatial fractionation of the MRT beams was clearly visible in 2D and up to 9 mm in depth. Individual microbeams were easily resolved with the full width at half maximum of microbeams measured on images with resolutions of as low as 0.09 μm/pixel. Profiles obtained demonstrated the change of the peak-to-valley dose ratio for interspersed MRT microbeam arrays and subtle variations in the sample positioning by the sample stage goniometer were measured. Conclusions: Laser fluorescence confocal microscopy of MRT irradiated PRESAGE® dosimeters has been validated in this study as a high resolution imaging tool for the independent spatial and geometrical verification of MRT beam delivery.

60 APPLIED LIFE SCIENCES↗

Characterization of scintillator-based detectors for few-ten-keV high-spatial-resolution x-ray imaging

Purpose: High-spatial-resolution x-ray imaging in the few-ten-keV range is becoming increasingly important in several applications, such as small-animal imaging and phase-contrast imaging. The detector properties critically influence the quality of such imaging. Here the authors present a quantitative comparison of scintillator-based detectors for this energy range and at high spatial frequencies. Methods: The authors determine the modulation transfer function, noise power spectrum (NPS), and detective quantum efficiency for Gadox, needle CsI, and structured CsI scintillators of different thicknesses and at different photon energies. An extended analysis of the NPS allows for direct measurements of the scintillator effective absorption efficiency and effective light yield as well as providing an alternative method to assess the underlying factors behind the detector properties. Results: There is a substantial difference in performance between the scintillators depending on the imaging task but in general, the CsI based scintillators perform better than the Gadox scintillators. At low energies (16 keV), a thin needle CsI scintillator has the best performance at all frequencies. At higher energies (28–38 keV), the thicker needle CsI scintillators and the structured CsI scintillator all have very good performance. The needle CsI scintillators have higher absorption efficiencies but the structured CsI scintillator has higher resolution. Conclusions: The choice of scintillator is greatly dependent on the imaging task. The presented comparison and methodology will assist the imaging scientist in optimizing their high-resolution few-ten-keV imaging system for best performance.

60 APPLIED LIFE SCIENCES↗

SU-F-I-16: Short Breast MRI with High-Resolution T2-Weighted and Dynamic Contrast Enhanced T1-Weighted Images

Purpose: To develop and demonstrate a short breast (sb) MRI protocol that acquires both T2-weighted and dynamic contrast-enhanced T1-weighted images in approximately ten minutes. Methods: The sb-MRI protocol consists of two novel pulse sequences. The first is a flexible fast spin-echo triple-echo Dixon (FTED) sequence for high-resolution fat-suppressed T2-weighted imaging, and the second is a 3D fast dual-echo spoiled gradient sequence (FLEX) for volumetric fat-suppressed T1-weighted imaging before and post contrast agent injection. The flexible FTED sequence replaces each single readout during every echo-spacing period of FSE with three fast-switching bipolar readouts to produce three raw images in a single acquisition. These three raw images are then post-processed using a Dixon algorithm to generate separate water-only and fat-only images. The FLEX sequence acquires two echoes using dual-echo readout after each RF excitation and the corresponding images are post-processed using a similar Dixon algorithm to yield water-only and fat-only images. The sb-MRI protocol was implemented on a 3T MRI scanner and used for patients who had undergone concurrent clinical MRI for breast cancer screening. Results: With the same scan parameters (eg, spatial coverage, field of view, spatial and temporal resolution) as the clinical protocol, the total scan-time of the sb-MRI protocol (including the localizer, bilateral T2-weighted, and dynamic contrast-enhanced T1-weighted images) was 11 minutes. In comparison, the clinical breast MRI protocol took 43 minutes. Uniform fat suppression and high image quality were consistently achieved by sb-MRI. Conclusion: We demonstrated a sb-MRI protocol comprising both T2-weighted and dynamic contrast-enhanced T1-weighted images can be performed in approximately ten minutes. The spatial and temporal resolution of the images easily satisfies the current breast MRI accreditation guidelines by the American College of Radiology. The protocol has the potential of making breast MRI more widely accessible to and more tolerable by the patients. JMA is the inventor of United States patents that are owned by the University of Texas Board of Regents and currently licensed to GE Healthcare and Siemens Gmbh.

60 APPLIED LIFE SCIENCES↗

Electronic structure at coarse-grained resolutions from supervised machine learning

Computational studies aimed at understanding conformationally dependent electronic structure in soft materials require a combination of classical and quantum-mechanical simulations, for which the sampling of conformational space can be particularly demanding. Coarse-grained (CG) models provide a means of accessing relevant time scales, but CG configurations must be back-mapped into atomistic representations to perform quantum-chemical calculations, which is computationally intensive and inconsistent with the spatial resolution of the CG models. A machine learning approach, denoted as artificial neural network electronic coarse graining (ANN-ECG), is presented here in which the conformationally dependent electronic structure of a molecule is mapped directly to CG pseudo-atom configurations. By averaging over decimated degrees of freedom, ANN-ECG accelerates simulations by eliminating backmapping and repeated quantum-chemical calculations. The approach is accurate, consistent with the CG spatial resolution, and can be used to identify computationally optimal CG resolutions.

36 MATERIALS SCIENCE↗

Ultrahigh-resolution scanning microwave impedance microscopy of moiré lattices and superstructures

Two-dimensional heterostructures composed of layers with slightly different lattice vectors exhibit new periodic structure known as moiré lattices, which, in turn, can support novel correlated and topological phenomena. Moreover, moiré superstructures can emerge from multiple misaligned moiré lattices or inhomogeneous strain distributions, offering additional degrees of freedom in tailoring electronic structure. High-resolution imaging of the moiré lattices and superstructures is critical for understanding the emerging physics. Here, we report the imaging of moiré lattices and superstructures in graphene-based samples under ambient conditions using an ultrahigh-resolution implementation of scanning microwave impedance microscopy. Although the probe tip has a gross radius of ~100 nm, spatial resolution better than 5 nm is achieved, which allows direct visualization of the structural details in moiré lattices and the composite super-moiré. We also demonstrate artificial synthesis of novel superstructures, including the Kagome moiré arising from the interplay between different layers.

36 MATERIALS SCIENCE↗

Structures of artificially designed discrete RNA nanoarchitectures at near-atomic resolution

Although advances in nanotechnology have enabled the construction of complex and functional synthetic nucleic acid–based nanoarchitectures, high-resolution discrete structures are lacking because of the difficulty in obtaining good diffracting crystals. Here, we report the design and construction of RNA nanostructures based on homooligomerizable one-stranded tiles for x-ray crystallographic determination. We solved three structures to near-atomic resolution: a 2D parallelogram, a 3D nanobracelet unexpectedly formed from an RNA designed for a nanocage, and, eventually, a bona fide 3D nanocage designed with the guidance of the two previous structures. Structural details of their constituent motifs, such as kissing loops, branched kissing loops, and T-junctions, that resemble natural RNA motifs and resisted x-ray determination are revealed, providing insights into those natural motifs. This work unveils the largely unexplored potential of crystallography in gaining high-resolution feedback for nanoarchitectural design and suggests a route to investigate RNA motif structures by configuring them into nanoarchitectures.

59 BASIC BIOLOGICAL SCIENCES↗