Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “RAMAN SPECTROSCOPY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,351 records · Page 75

Quantitative far-infrared band strengths of iodine monochloride (ICl), a molten salt off-gas product

The gaseous (by)products generated from molten salt reactors need to be monitored to prevent the release of potentially toxic gases to the environment. In particular, 129I has a long half-life and its toxicity and persistence in the environment make iodine and iodine-containing compounds (such as ICl from chloride containing molten salt systems) of great concern. Optical spectroscopy tools, including Raman and Fourier-transform infrared (FTIR) spectroscopies, are ideal for monitoring and quantifying such off-gas products. Iodine (I2) has a strong and distinct Raman signature and the change in signal with a change in concentration can be used for quantification of these byproducts. Iodine monochloride (ICl) has distinct signatures in both the Raman and the infrared, and its spectrum can also potentially be used for quantitative measurement of this species. In this paper we discuss our recent results on the quantification of iodine monochloride using infrared spectroscopy, in particular first reports of the absolute infrared band strength of ICl.

infrared (IR) spectroscopy, Molten Salt Reactors, ↗

Observation of pressure-induced electron transfer in SnC 2 O 4

We examined the high pressure behavior of stannous oxalate via Raman and X-ray absorption spectroscopy (XAS) inside a diamond anvil cell. Phase transitions were observed to occur near 2.6 and 15 GPa which were reversible upon decompression to ambient conditions. When further pressurized above 15 GPa, the colorless material sustains irreversible chemical alterations and becomes bright red colored – darkening at higher pressures. Another irreversible phase transition occurred above 20 GPa. Concomitant with color change of the sample, we observed a softening of the ν(C–C) modes of the C 2 O 4 2- anion via Raman spectroscopy. We performed a separate XAS experiment which indicates that the Sn 2+ cation undergoes a partial reduction of the 2+ oxidation state with pressure which persists when the sample was depressurized to ambient conditions. Thus, electron density within the C–C bond in the oxalate anion appears to migrate toward the tin cation with pressure. This observation suggests that pressure can offer a very controllable means to vary cation–anion and unit cell dimensions (and thus the electric interactions causing electron movement) and thus the pressure-induced synthesis of novel materials.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Influence of heterocyclic N-donors on the structural topologies and vibrational spectra of uranyl selenate phases

Uranyl (U(VI)O 2 2+ ) selenate compounds represent a well-studied family of structures with diverse structural arrays. Differences in the overall topology and bonding with the uranyl cation combined with additional intermolecular interactions can lead to variation in the resulting spectroscopic signals. Here, in the current study, we evaluated the structural chemistry and vibrational spectroscopy for uranyl selenates crystallized with heterocyclic N-donors. Five compounds ((C 4 H 12 N 2 )[(UO 2 )(SeO 4 ) 2 (H 2 O)]·H 2 O (USe_pip), (C 4 H 5 N 2 ) 2 [(UO 2 )(SeO 4 ) 2 (H 2 O)] (USe_pyrdz), (C 5 H 5 N) 2 [(UO 2 ) 2 (SeO 4 ) 3 (H 2 O)] ∙ 3H 2 O (USe_pyrmd), (H 3 O) 2 (C 4 H 5 N 2 ) 2 [(UO 2 ) 3 (SeO 4 ) 5 (H 2 O)]·H 2 O (USe_pyrz), and (C 5 H 6 N) 2 [(UO 2 ) 2 (SeO 4 ) 3 (H 2 O)] ∙ 3H 2 O (USe_pyr)) were characterized using X-ray diffraction (single-crystal and powder) and vibrational (Raman and IR) spectroscopy. Two one-dimensional (1-D) chain and three two-dimensional sheet (2-D) topologies were identified and classified based upon previous graphical representations. Overall, the arrangement of the heteroatoms could be linked to the hydrogen bonding network associated with the heterocycles and selenate anions. Vibrational spectra of the solid-state compounds were complex, with multiple bands associated with the uranyl cation, selenate anion, and heteroatoms. The ν 1 symmetric stretching band of the uranyl was relatively consistent across all compounds, whereas differences were observed for the ν 3 asymmetric band between the 1-D and 2-D structural topologies.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The SuperCam Instrument Suite on the Mars 2020 Rover: Science Objectives and Mast-Unit Description

On the NASA 2020 rover mission to Jezero crater, the remote determination of the texture, mineralogy and chemistry of rocks is essential to quickly and thoroughly characterize an area and to optimize the selection of samples for return to Earth. As part of the Perseverance payload, SuperCam is a suite of five techniques that provide critical and complementary observations via Laser-Induced Breakdown Spectroscopy (LIBS), Time-Resolved Raman and Luminescence (TRR/L), visible and near-infrared spectroscopy (VISIR), high-resolution color imaging (RMI), and acoustic recording (MIC). SuperCam operates at remote distances, primarily 2–7 m, while providing data at sub-mm to mm scales. We report on SuperCam’s science objectives in the context of the Mars 2020 mission goals and ways the different techniques can address these questions. The instrument is made up of three separate subsystems: the Mast Unit is designed and built in France; the Body Unit is provided by the United States; the calibration target holder is contributed by Spain, and the targets themselves by the entire science team. This publication focuses on the design, development, and tests of the Mast Unit; companion papers describe the other units. The goal of this work is to provide an understanding of the technical choices made, the constraints that were imposed, and ultimately the validated performance of the flight model as it leaves Earth, and it will serve as the foundation for Mars operations and future processing of the data.

47 OTHER INSTRUMENTATION↗

Endogenous Production and Vibrational Analysis of Heavy-Isotope-Labeled Peptides from Cyanobacteria

Stable isotope labeling is an extremely useful tool for characterizing the structure, tracing the metabolism, and imaging the distribution of natural products in living organisms using mass-sensitive measurement techniques. In this study, a cyanobacterium was cultured in 15 N/ 13 C-enriched media to endogenously produce labeled, bioactive oligopeptides. The extent of heavy isotope incorporation in these peptides was determined with LC–MS, while the overall extent of heavy isotope incorporation in whole cells was studied with nanoSIMS and AFM-IR. Up to 98 % heavy isotope incorporation was observed in labeled cells. Three of the most abundant peptides, microcystin-LR (MCLR), cyanopeptolin-A (CYPA), and aerucyclamide-A (ACAA), were isolated and further studied with Raman and FTIR spectroscopies and DFT calculations. This revealed several IR and Raman active vibrations associated with functional groups not common in ribosomal peptides, like diene, ester, thiazole, thiazoline, and oxazoline groups, which could be suitable for future vibrational imaging studies. More broadly, this study outlines a simple and relatively inexpensive method for producing heavy-labeled natural products. Finally, manipulating the bacterial culture conditions by the addition of specific types and amounts of heavy-labeled nutrients provides an efficient means of producing heavy-labeled natural products for mass-sensitive imaging studies.

60 APPLIED LIFE SCIENCES↗

Temperature-induced hexagonal–orthorhombic phase transition in lutetium ferrite nanoparticles

The x-ray diffraction, Raman, and infrared spectroscopies and magnetic measurements were used to explore the correlated changes of the structure, lattice dynamics, and magnetic properties of the LuFeO3 nanoparticles, which appear in dependence on their sintering temperature. We revealed a gradual substitution of the hexagonal phase by the orthorhombic phase in the nanoparticles, with sintering temperature increasing from 700 to 1100 °C. The origin and stability of the hexagonal phase in the LuFeO3 nanoparticles are of the special interest, because the nanoparticles in the phase can be a room-temperature multiferroic with a weak ferromagnetic and pronounced structural and ferroelectric long-range ordering. The antiferromagnetic and nonpolar orthorhombic phase is more stable in the bulk LuFeO3. To define the ranges of the hexagonal phase stability, we determine the bulk and interface energy densities of different phases from the comparison of the Gibbs model with experimental results. Using effective parameters of the Gibbs model, we predict the influence of size effects and temperature on the structural and polar properties of the LuFeO3 nanoparticles. Analysis of the obtained results shows that the combination of the x-ray diffraction, Raman and infrared spectroscopies, magnetic measurements, and theoretical modeling of structural and polar properties allows us to establish the interplay between the phase composition, lattice dynamics, and multiferroic properties of the LuFeO3 nanoparticles prepared under different conditions.

Materials Science↗

Temperature Measurements in Hypersonic Wind Tunnels via Femtosecond Coherent Anti-Stokes Raman Scattering

A femtosecond coherent anti-Stokes Raman scattering (fs CARS) instrument is developed to perform gas-phase thermometry in cold-flow hypersonic wind tunnels. Measurements are reported for Mach 8 and 14 pure-nitrogen flows. The fs CARS instrument includes a 100 fs pump/Stokes pulse and a spectrally narrow probe pulse from a second harmonic bandwidth compressor. Important experimental considerations such as limits on the pump/Stokes pulse energy are discussed. The fs CARS focusing and collimating optics are mounted on a two-axis translation stage system to scan the measurement location during a 30 second wind tunnel run. Single-laser-shot rotational CARS spectra are recorded at the laser repetition rate of 1 kHz in the wind tunnel freestream and near simple cone models. Spectral fitting is used to determine quantitative gas temperatures. Freestream temperatures at Mach 8 and 14 spanned ranges of 40–75 and 35–50 K, respectively, depending on tunnel operating conditions. Temperature variations across the central 100 mm span of the wind tunnel were quantified. Measured temperature jumps across conical bow shocks from various models varied by less than 1% from predicted values. Hypersonic boundary layer measurements were demonstrated. In conclusion, these measurements illustrate the utility and robustness of this instrument for the study of complex fluid flow phenomena in challenging ground test facilities.

Aerodynamics↗

Perseverance’s Scanning Habitable Environments with Raman and Luminescence for Organics and Chemicals (SHERLOC) Investigation

The Scanning Habitable Environments with Raman and Luminescence for Organics and Chemicals (SHERLOC) is a robotic arm-mounted instrument on NASA’s Perseverance rover. SHERLOC has two primary boresights. The Spectroscopy boresight generates spatially resolved chemical maps using fluorescence and Raman spectroscopy coupled to microscopic images (10.1 μm/pixel). The second boresight is a Wide Angle Topographic Sensor for Operations and eNgineering (WATSON); a copy of the Mars Science Laboratory (MSL) Mars Hand Lens Imager (MAHLI) that obtains color images from microscopic scales (~13 μm/pixel) to infinity. SHERLOC Spectroscopy focuses a 40 μs pulsed deep UV neon-copper laser (248.6 nm), to a ~100 μm spot on a target at a working distance of ~48 mm. Fluorescence emissions from organics, and Raman scattered photons from organics and minerals, are spectrally resolved with a single diffractive grating spectrograph with a spectral range of 250 to ~370 nm. Because the fluorescence and Raman regions are naturally separated with deep UV excitation (<250 nm), the Raman region ~ 800 – 4000 cm -1 (250 to 273 nm) and the fluorescence region (274 to ~370 nm) are acquired simultaneously without time gating or additional mechanisms. SHERLOC science begins by using an Autofocus Context Imager (ACI) to obtain target focus and acquire 10.1 μm/pixel greyscale images. Chemical maps of organic and mineral signatures are acquired by the orchestration of an internal scanning mirror that moves the focused laser spot across discrete points on the target surface where spectra are captured on the spectrometer detector. ACI images and chemical maps (< 100 μm/mapping pixel) will enable the first Mars in situ view of the spatial distribution and interaction between organics, minerals, and chemicals important to the assessment of potential biogenicity (containing CHNOPS). Single robotic arm placement chemical maps can cover areas up to 7x7 mm in area and, with the < 10 min acquisition time per map, larger mosaics are possible with arm movements. This microscopic view of the organic geochemistry of a target at the Perseverance field site, when combined with the other instruments, such as Mastcam-Z, PIXL, and SuperCam, will enable unprecedented analysis of geological materials for both scientific research and determination of which samples to collect and cache for Mars sample return.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Magneto-structural and induction heating properties of MFe2O4 (M?=?Co, Mn, Zn) MNPs for magnetic particle hyperthermia application

The thermal decomposition approach was used for the synthesis of MFe2O4 magnetic nanoparticles (MNPs) by substituting M as Co, Mn, and Zn. The obtained MNPs were characterized for magneto-structural properties using X-Ray diffraction patterns, FTIR, Raman and Mossbauer spectroscopy techniques which confirm the formation of phase pure cubic spinel ferrite with space group Fd3m and five Raman active modes. The size, morphology, and compositional analysis was performed using HRTEM and EDX where the size of MNPs was found to be less than 10 nm that attains superparamagnetism. The magnetic hyperthermia performance of obtained MNPs was evaluated by induction heating experiments at magnetic field range 13.3 to 26.7 kAm-1. The specific absorption rate (SAR) and intrinsic loss power (ILP) values were determined at different magnetic fields within the human tolerable range and correlated with magneto-structural properties to evaluate its potential for possible magnetic particle hyperthermia therapy.

Magnetic nanoparticles, complex-decomposition, mag↗

Coherent anti-Stokes Raman scattering with squeezed light: CARS for quantum-enhanced spectroscopy and imaging

We theoretically investigate quantum-enhanced coherent anti-Stokes Raman scattering (CARS) using squeezed light to amplify vibrational transition rates at low photon flux. Quantum sensing approaches are needed for nondestructive nanometrology such as in bioimaging where reduced photodamage is desired while retaining resolution and sensitivity. We analyze both single-mode squeezing applied to the pump field and two-mode squeezing between the pump and Stokes fields. We also show that the ordering of displacement and squeezing operations—whether displacement precedes squeezing or squeezing precedes displacement—has an impact on the resulting CARS transition amplitudes due to a difference in the photon number and the quantum-enhancement coefficients, with the latter offering a stronger enhancement in the case of two modes squeezing of the pump and Stokes under experimentally accessible conditions. Furthermore, our calculations capture these quantum enhancements through the intrinsic photon-number correlations of squeezed light, eliminating the need for interferometric detection or higher pump powers that are otherwise required to reach comparable sensitivities in classical CARS. Finally, we outline a quantum plasmonic extension of our model in which local field enhancements caused by surface plasmon excitation in metallic nanoparticles can be incorporated via mode-selective field amplification factors, offering a pathway toward combining squeezed-light quantum optics with surface-enhanced nanoscale spectroscopy and imaging.

Atomic & molecular structure↗

Optical vibrational spectroscopic signatures of ammonium diuranate process parameters

Ammonium diuranate (ADU) is commonly encountered in the nuclear fuel cycle; however, previous investigations have shown that ADU is a complex mixture of distinct compounds. Moreover, production parameters are known to heavily influence the composition of the resulting ADU. Here, we examine four samples of ADU prepared at Oak Ridge National Laboratory (ORNL), and one sample of ADU made at Pacific Northwest National Laboratory (PNNL), with the goal of further characterizing and elucidating the effect of processing parameters such as stir rate, strike direction, and temperature on material composition. Process parameters during ADU precipitation at ORNL and PNNL were well documented, and we relate process variables to optical vibrational spectroscopic signatures observed using Raman and infrared (IR) spectroscopy. In addition, powder X-ray diffraction (PXRD) reveals differences in the solid-phase composition of ADU precipitates, but we find that the primary phase is similar to the uranyl oxyhydroxyhydrate mineral metaschoepite. Despite the significant phase contributions of a metaschoepite-like phase, spectroscopic evidence of both nitrate and ammonium are observed for all samples. To gain a more holistic understanding of spectroscopic features of process parameters in ADU, principal component analysis (PCA) is employed and results in observable signatures that relate to the stir rate used during synthesis. These results provide further information about the process-dependence of ADU precipitate composition.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Radiolytic degradation of 240 Plutonium and 242 Plutonium oxalates

Raman, FTIR, and diffuse reflectance spectroscopy were used to study the auto-radiolytic degradation of 240 Pu and 242 Pu oxalates. The significant differences in the lifetimes of 240 Pu and 242 Pu enabled the differentiation between environmental and radiolytic mechanisms. 240 Pu oxalates were observed to decompose to PuOCO 3 at intermediate times (~ 20 weeks) followed by partial conversion to PuO 2 at times greater than one year. Atmospheric oxidation was shown to be the primary decomposition mechanism for 242 Pu(IV) oxalate, and the alpha radiolysis of aquo and oxalate ligands serves as a secondary decomposition mechanism. In conclusion, this study offers a fresh perspective on radiolytic aging, which is crucial for long-term storage applications.

Analytical Techniques in Art Conservation↗

SuperCam Calibration Targets: Design and Development

Abstract SuperCam is a highly integrated remote-sensing instrumental suite for NASA’s Mars 2020 mission. It consists of a co-aligned combination of Laser-Induced Breakdown Spectroscopy (LIBS), Time-Resolved Raman and Luminescence (TRR/L), Visible and Infrared Spectroscopy (VISIR), together with sound recording (MIC) and high-magnification imaging techniques (RMI). They provide information on the mineralogy, geochemistry and mineral context around the Perseverance Rover. The calibration of this complex suite is a major challenge. Not only does each technique require its own standards or references, their combination also introduces new requirements to obtain optimal scientific output. Elemental composition, molecular vibrational features, fluorescence, morphology and texture provide a full picture of the sample with spectral information that needs to be co-aligned, correlated, and individually calibrated. The resulting hardware includes different kinds of targets, each one covering different needs of the instrument. Standards for imaging calibration, geological samples for mineral identification and chemometric calculations or spectral references to calibrate and evaluate the health of the instrument, are all included in the SuperCam Calibration Target (SCCT). The system also includes a specifically designed assembly in which the samples are mounted. This hardware allows the targets to survive the harsh environmental conditions of the launch, cruise, landing and operation on Mars during the whole mission. Here we summarize the design, development, integration, verification and functional testing of the SCCT. This work includes some key results obtained to verify the scientific outcome of the SuperCam system.

Manrique, J. A. (ORCID:0000000220532819)↗

Impact of moderate pump–Stokes chirp on femtosecond coherent anti-Stokes Raman scattering spectra

The effects of inducing moderate chirp in the pump and Stokes beams in chirped-probe-pulse femtosecond coherent anti-Stokes Raman scattering (CARS) spectroscopy are discussed. This is an important issue for measurements in high-pressure systems where the CARS beams must be transmitted through glass of significant thickness to reach the probe volume of interest. The effects were investigated both experimentally, by inserting disks of SF-11 glass into the pump and Stokes beam paths, and theoretically, by incorporating pulse chirp into our time-dependent density matrix (TDDM) simulations. Experimentally, we found that inducing moderate pump and Stokes chirp produced significant spectral narrowing of the nonresonant four-wave mixing contribution to the CARS signal, and this allowed us to control the resonant excitation bandwidth to eliminate interferences from neighboring species. The temperature measurement accuracy and precision were essentially unchanged with respect to the unchirped pump and Stokes case. The effect of moderate pump and Stokes chirp on the narrowing of the Raman excitation efficiency envelope was investigated by solving the full set of TDDM through direct numerical integration. The numerical efficiency of the solutions was enhanced dramatically by developing a parallel version of the TDDM code. The calculated Raman excitation efficiency profile was incorporated in our phenomenological spectral fitting codes.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗