Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “RADIATION INTENSITY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,351 records · Page 75

SU-E-T-410: Evaluation of Treatment Modalities for Stereotactic Lung Radiation Therapy: A Phantom Study

Purpose: To evaluate and verify the accuracy of alternative treatment modalities for stereotactic lung therapy with end-to-end testing. We compared three dimensional conformal therapy (3DCRT), dynamic conformal arc therapy (DCAT), intensity modulated radiation therapy (IMRT) and volumetric modulated arc therapy (VMAT) treatment using 6 MV, 6 MV flattening filter free (FFF) and 10 MV FFF photons. Methods: A QUASAR respiratory motion phantom was utilized with custom ion chamber and gafchromatic EBT2 film inserts. The phantom contained a low density lung medium with a cylindrical polystyrene tumor (35 cc). Pseudo representative structures for various organs at risk (OAR) were created. All treatment plans were created using Eclipse ver. 11 using the same image and structure sets, and delivered via Varian TrueBeam STx linear accelerator equipped with high definition MLC. Evaluation of plan quality followed ROTG 0813 criterion for conformity index (CI100%), high dose spillage, D2cm, and R50%. Results: All treatment plans met the OAR dose constraints per protocol and could be delivered without any beam hold offs or other interlocks and hence were deemed clinically safe. For equivalent beam energies, target conformity was improved for all modalities when switching to FFF mode. Treatment efficiency increased for VMAT FFF by a factor of 3–4 over IMRT, and up to factor of 7 when compared to 3DCRT. Pass rates were > 97% for all treatment using gamma criteria of 3%, 3mm. Absolute dose at iso-center was verified with ion chamber, and found to be within 2% of the treatment planning system. Conclusion: The higher dose rate associated with FFF not only reduces delivery times, but in most cases enhances plan quality. The one modality with succeeding best results for all RTOG criterions was VMAT 6 MV FFF. This end-to-end testing provides necessary confidence in the entire dose delivery chain for lung SBRT patients.

43 PARTICLE ACCELERATORS↗

Newer Imaging Modalities to Assist With Target Localization in the Radiation Treatment of Prostate Cancer and Possible Lymph Node Metastases

Precise localization of prostate cancer and the drainage lymph nodes is mandatory to define an accurate clinical target volume for conformal radiotherapy. Better target definition and delineation on a daily basis is surely important in quality assurance for fractionated radiation therapy. This article reviews the evidence for major emerging techniques that show promise in better identifying the clinical target volume. Partial prostate boost by brachytherapy, intensity-modulated radiation therapy, or protons has become possible not only with standard imaging techniques but also with the availability of metabolic images obtained by magnetic resonance spectroscopy. Even though fluorine-18 fluorodeoxyglucose ({sup 18}F-FDG) positron emission tomography has not been found to be useful, novel radiolabeled tracers may eventually prove of value in the diagnosis and treatment planning of prostate cancer. For the metastatic lymph nodes, lymphotropic nanoparticle-enhanced magnetic resonance imaging using ultra-small superparamagnetic iron oxide particles has greater accuracy as compared with conventional techniques and has been instrumental in delineating the lymphatic drainage of the prostate gland. These novel investigational techniques could further help in optimizing conformal radiotherapy for patients with prostate cancer. The concepts of biologic target volume, real target volume, and multidimensional conformal radiotherapy are being explored.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Studies of planetary boundary layer by infrared thermal imagery

The IR camera is a relatively novel device for remote sensing of atmospheric thermal processes from the Planetary Boundary Layer (PBL) based on measurements of the infrared radiation. Infrared radiation is energy radiated by the motion of atoms and molecules on the surface of aerosols, when their temperature is more than absolute zero. The IR camera measures directly the intensity of radiation emitted by aerosols which is converted by an imaging sensor into an electric signal, resulting a thermal image. Every image pixel that corresponds to a specific radiance is pre-processed to identify the brightness temperature. The thermal infrared imaging radiometer used in this study, NicAir, is a precision radiometer developed by Prata et al. The device was calibrated for the temperature range of 270–320 K and using a calibration table along with image processing software, important information about variations in temperature can be extracted from acquired IR images. The PBL is the lowest layer of the troposphere where the atmosphere interacts with the ground surfaces. The importance of PBL lies in the fact that it provides a finite but varying volume in which pollutants can disperse. The aim of this paper is to analyze the PBL altitude and thickness variations over Iasi region using the IR imaging camera as well as its behavior from day to night and thermal processes occurring in PBL.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Quality Control Quantification (QCQ): A Tool to Measure the Value of Quality Control Checks in Radiation Oncology

Purpose: To quantify the error-detection effectiveness of commonly used quality control (QC) measures. Methods: We analyzed incidents from 2007-2010 logged into a voluntary in-house, electronic incident learning systems at 2 academic radiation oncology clinics. None of the incidents resulted in patient harm. Each incident was graded for potential severity using the French Nuclear Safety Authority scoring scale; high potential severity incidents (score >3) were considered, along with a subset of 30 randomly chosen low severity incidents. Each report was evaluated to identify which of 15 common QC checks could have detected it. The effectiveness was calculated, defined as the percentage of incidents that each QC measure could detect, both for individual QC checks and for combinations of checks. Results: In total, 4407 incidents were reported, 292 of which had high-potential severity. High- and low-severity incidents were detectable by 4.0 {+-} 2.3 (mean {+-} SD) and 2.6 {+-} 1.4 QC checks, respectively (P<.001). All individual checks were less than 50% sensitive with the exception of pretreatment plan review by a physicist (63%). An effectiveness of 97% was achieved with 7 checks used in combination and was not further improved with more checks. The combination of checks with the highest effectiveness includes physics plan review, physician plan review, Electronic Portal Imaging Device-based in vivo portal dosimetry, radiation therapist timeout, weekly physics chart check, the use of checklists, port films, and source-to-skin distance checks. Some commonly used QC checks such as pretreatment intensity modulated radiation therapy QA do not substantially add to the ability to detect errors in these data. Conclusions: The effectiveness of QC measures in radiation oncology depends sensitively on which checks are used and in which combinations. A small percentage of errors cannot be detected by any of the standard formal QC checks currently in broad use, suggesting that further improvements are needed. These data require confirmation with a broader incident-reporting database.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Tumor histology and location predict deep nuclei toxicity: Implications for late effects from focal brain irradiation

Normal tissue toxicity resulting from both disease and treatment is an adverse side effect in the management of patients with central nervous system malignancies. We tested the hypothesis that despite these improvements, certain tumors place patients at risk for neurocognitive, neuroendocrine, and neurosensory late effects. Defining patient groups at risk for these effects could allow for development of preventive strategies. Fifty patients with primary brain tumors underwent radiation planning with magnetic resonance imaging scan and computed tomography datasets. Organs at risk (OAR) responsible for neurocognitive, neuroendocrine, and neurosensory function were defined. Inverse-planned intensity-modulated radiation therapy was optimized with priority given to target coverage while penalties were assigned to exceeding normal tissue tolerances. Tumor laterality, location, and histology were compared with OAR doses, and analysis of variance was performed to determine the significance of any observed correlation. The ipsilateral hippocampus exceeded dose limits in frontal (74%), temporal (94%), and parietal (100%) lobe tumor locations. The contralateral hippocampus was at risk in the following tumor locations: frontal (53%), temporal (83%), or parietal (50%) lobe. Patients with high-grade glioma were at risk for ipsilateral (88%) and contralateral (73%) hippocampal damage (P <0.05 compared with other histologies). The pituitary gland and hypothalamus exceeded dose tolerances in patients with pituitary tumors (both 100%) and high-grade gliomas (50% and 75%, P <0.05 compared with other histologies), respectively. Despite application of modern radiation therapy, certain tumor locations and histologies continue to place patients at risk for morbidity. Patients with high-grade gliomas or tumors located in the frontal, temporal, or parietal lobes are at risk for neurocognitive decline, likely because of larger target volumes and higher radiation doses. Data from this study may help to stratify patients at risk for late effects to develop strategies to reduce frequency and severity of radiation sequelae.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-F-T-212: A Comparison of Treatment Strategies for Intracranial Stereotactic Radiosurgery

Purpose: Stereotactic radiosurgery is an effective and noninvasive treatment for intracranial lesions that uses highly focused radiation beams in a single treatment fraction. The purpose of this study is to investigate the dosimetric differences between the treatment brain metastasis with a proton beam vs. intensity modulated radiation therapy (IMRT). Methods: Ten separate brain metastasis targets where chosen and treatment plans were created for each, using three different strategies: custom proton beam shaping devices, standardized proton beam shaping devices, and IMRT. Each plan was required to satisfy set parameters for providing adequate coverage and minimizing risk to adjacent tissues. The effectiveness of each plan was calculated by comparing the homogeneity index, conformity index, and V12 for each target using a paired one tailed T-test (α=0.05). Specific comparison of the conformity indices was also made using a subcategory containing targets with volume>1cc. Results: There was no significant difference between the homogeneity indices of the three plans (p>0.05), showing that each plan has the capability of adequately covering the targets. There was a statistically significant difference (p<0.01) between the conformity indices of the custom and the standard proton plan, as with the custom proton and IMRT (p<0.01), with custom proton showing stronger conformity to the target in both cases. There was also a statistical difference between the V12 of all three plans (Custom v. Standardized: p=0.02, Custom v. IMRT: p<0.01, Standardized v. IMRT: p<0.01) with custom proton supplying the lowest dose to surrounding tissues. For large targets (volume>1cc) there was no statistical difference between the proton plans and the IMRT treatment for the conformity index. Conclusion: A custom proton plan is the recommended treatment explored in this study as it is the most reliable way of effectively treating the target while sparing the maximum amount of normal tissue.

60 APPLIED LIFE SCIENCES↗

Baffle design for earth radiation rejection in the Cryogenic Limb-Scanning Interferometer/Radiometer

The Cryogenic Limb-Scanning Interferometer/Radiometer (CLIR) is being developed to observe infrared emissions of the earth's upper atmosphere from space. The earth's surface is an extended source of intense background radiation with a small angular separation from the desired scene. The CLIR employs an off-axis Gregorian Telescope whose primary mirror and baffles are cooled by an open-cycle cryogen system. A system of specular annular baffles has been developed to minimize both stray light problems and cryogen consumption by retro-mapping the aperture into itself. Each off-axis ray which enters the aperture and strikes the specular baffle surface is reflected so that it passes out of the aperture and is not absorbed on a cryogenic surface. The specular baffle which lies closest to the aperture is an ellipsoid whose foci trace out the circular aperture on revolution about the axis. Its theoretical 'ray trace' efficiency is 100 percent. A subsequent baffle has an elliptical cross section whose near focus traces out the central hole in the ellipsoidal baffle and whose far focus traces out the aperture. Its theoretical efficiency is about 90 percent. These baffles reduce the earth radiation heat load on the cryogenic cooler by an order of magnitude, changing it from the dominant cause of cryogen consumption to a relatively small effect. An aperture shield is also desirable to reduce cryogen consumption, stray light, and contamination.

Bremer, J. C.↗

MCM Polarimetric Radiometers for Planar Arrays

A polarimetric radiometer that operates at a frequency of 40 GHz has been designed and built as a prototype of multiple identical units that could be arranged in a planar array for scientific measurements. Such an array is planned for use in studying the cosmic microwave background (CMB). All of the subsystems and components of this polarimetric radiometer are integrated into a single multi-chip module (MCM) of substantially planar geometry. In comparison with traditional designs of polarimetric radiometers, the MCM design is expected to greatly reduce the cost per unit in an array of many such units. The design of the unit is dictated partly by a requirement, in the planned CMB application, to measure the Stokes parameters I, Q, and U of the CMB radiation with high sensitivity. (A complete definition of the Stokes parameters would exceed the scope of this article. In necessarily oversimplified terms, I is a measure of total intensity of radiation, while Q and U are measures of the relationships between the horizontally and vertically polarized components of radiation.) Because the sensitivity of a single polarimeter cannot be increased significantly, the only way to satisfy the high-sensitivity requirement is to make a large array of polarimeters that operate in parallel. The MCM includes contact pins that can be plugged into receptacles on a standard printed-circuit board (PCB). All of the required microwave functionality is implemented within the MCM; any required supporting non-microwave ("back-end") electronic functionality, including the provision of DC bias and control signals, can be implemented by standard PCB techniques. On the way from a microwave antenna to the MCM, the incoming microwave signal passes through an orthomode transducer (OMT), which splits the radiation into an h + i(nu) beam and an h - i(nu) beam (where, using complex-number notation, h denotes the horizontal component, nu denotes the vertical component, and +/-i denotes a +/-90deg phase shift). Each of these beams enters the MCM through one of two WR-22 waveguide input terminals in the lid of the MCM. The h + i(nu0 and h - i(nu) signals are amplified, then fed to a phase-discriminator hybrid designed specifically to fit the predominantly planar character of the MCM geometry and to enable determination of Q and U. The phase-discriminator hybrid generates four outputs, which are detected and used to calculate I, Q, and U.

Kangaslahti, Pekka↗

SAS 2 observations of the earth albedo gamma radiation above 35 MeV

The earth albedo gamma radiation above 35 MeV in the equatorial region is investigated using observations from the second Small Astronomy Satellite. The zenith angle distribution of the gamma radiation has a peak toward the horizon which is about an order of magnitude more intense than the radiation coming from the nadir, and nearly two orders of magnitude more intense than the gamma radiation from most parts of the sky. The gamma radiation originating from the western horizon is a factor of four more intense than the radiation from the eastern horizon and a factor of three more intense than that from the northern and southern directions. This reflects the geomagnetic effects on the incident cosmic rays whose interactions produce the albedo gamma rays. The variation of the upcoming gamma ray intensity with vertical cutoff rigidity is consistent with the empirical relationship found by Gur'yan et al. (1979).

Thompson, D. J.↗

Adaptive Radiation Therapy for Postprostatectomy Patients Using Real-Time Electromagnetic Target Motion Tracking During External Beam Radiation Therapy

Purpose: Using real-time electromagnetic (EM) transponder tracking data recorded by the Calypso 4D Localization System, we report inter- and intrafractional target motion of the prostate bed, describe a strategy to evaluate treatment adequacy in postprostatectomy patients receiving intensity modulated radiation therapy (IMRT), and propose an adaptive workflow. Methods and Materials: Tracking data recorded by Calypso EM transponders was analyzed for postprostatectomy patients that underwent step-and-shoot IMRT. Rigid target motion parameters during beam delivery were calculated from recorded transponder positions in 16 patients with rigid transponder geometry. The delivered doses to the clinical target volume (CTV) were estimated from the planned dose matrix and the target motion for the first 3, 5, 10, and all fractions. Treatment adequacy was determined by comparing the delivered minimum dose (D{sub min}) with the planned D{sub min} to the CTV. Treatments were considered adequate if the delivered CTV D{sub min} is at least 95% of the planned CTV D{sub min}. Results: Translational target motion was minimal for all 16 patients (mean: 0.02 cm; range: −0.12 cm to 0.07 cm). Rotational motion was patient-specific, and maximum pitch, yaw, and roll were 12.2, 4.1, and 10.5°, respectively. We observed inadequate treatments in 5 patients. In these treatments, we observed greater target rotations along with large distances between the CTV centroid and transponder centroid. The treatment adequacy from the initial 10 fractions successfully predicted the overall adequacy in 4 of 5 inadequate treatments and 10 of 11 adequate treatments. Conclusion: Target rotational motion could cause underdosage to partial volume of the postprostatectomy targets. Our adaptive treatment strategy is applicable to post-prostatectomy patients receiving IMRT to evaluate and improve radiation therapy delivery.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dosimetric evaluation of 4 different treatment modalities for curative-intent stereotactic body radiation therapy for isolated thoracic spinal metastases

To investigate the dosimetric characteristics of 4 SBRT-capable dose delivery systems, CyberKnife (CK), Helical TomoTherapy (HT), Volumetric Modulated Arc Therapy (VMAT) by Varian RapidArc (RA), and segmental step-and-shoot intensity-modulated radiation therapy (IMRT) by Elekta, on isolated thoracic spinal lesions. CK, HT, RA, and IMRT planning were performed simultaneously for 10 randomly selected patients with 6 body types and 6 body + pedicle types with isolated thoracic lesions. The prescription was set with curative intent and dose of either 33 Gy in 3 fractions (3F) or 40 Gy in 5F to cover at least 90% of the planning target volume (PTV), correspondingly. Different dosimetric indices, beam-on time, and monitor units (MUs) were evaluated to compare the advantages/disadvantages of each delivery modality. In ensuring the dose-volume constraints for cord and esophagus of the premise, CK, HT, and RA all achieved a sharp conformity index (CI) and a small penumbra volume compared to IMRT. RA achieved a CI comparable to those from CK, HT, and IMRT. CK had a heterogeneous dose distribution in the target as its radiosurgical nature with less dose uniformity inside the target. CK had the longest beam-on time and the largest MUs, followed by HT and RA. IMRT presented the shortest beam-on time and the least MUs delivery. For the body-type lesions, CK, HT, and RA satisfied the target coverage criterion in 6 cases, but the criterion was satisfied in only 3 (50%) cases with the IMRT technique. For the body + pedicle-type lesions, HT satisfied the criterion of the target coverage of ≥90% in 4 of the 6 cases, and reached a target coverage of 89.0% in another case. However, the criterion of the target coverage of ≥90% was reached in 2 cases by CK and RA, and only in 1 case by IMRT. For curative-intent SBRT of isolated thoracic spinal lesions, RA is the first choice for the body-type lesions owing to its delivery efficiency (time); the second choice is CK or HT; HT is the preferential choice for the body + pedicle-type lesions. This study suggests further clinical investigations with longer follow-up for these studied cases.

61 RADIATION PROTECTION AND DOSIMETRY↗

The Strontium Filament within the Homunculus of Eta Carinae

During a series of HST/STIS observations of Eta Carinae and associated ejecta, we noticed a peculiar emission filament located a few arcseconds north of the central source. While bright in nebular standards, it is submerged in a sea of scattered starlight until moderately high dispersion, long-slit spectroscopy with the STIS (R- 8000) brings the emission lines out. The initial spectrum, centered on 6768A with the STIS G750M grating, led to identification of twenty lines from singly-Ionized species including [Sr II], [Fe II], [Ti II], [Ni II], [Mn II], and [Co II] (Zethson, etal., 2001, AJ 122,322). No Balmer emission is detected from this filament and the Fe II 2507,9 lines, known to be pumped by Lyman alpha radiation in other regions near the central source, are not detected. Followup observations have led to detection of hundreds more emission lines from iron group elements in neutral and singly-ionized states. Thus far all are excited by less than 10 eV. This peculiar nebular emission is thought to be due to very intense stellar radiation, stripped of uv flux shortward of Lyman alpha, bathing a neutral structure. We are systematically identifying the many lines (over 90% identified) and measuring line intensities that will then be modeled to determine excitation mechanisms, temperature and density. Two [Sr II] and two Sr II lines have now been measured. Bautista, etal. (in preparation) have modeled the strontium flux ratios and find that large radiation fluxes and/or high strontium abundances may account for the detected emission. These observations were supported by STIS GTO funding and GO funding through the STScI

Gull, Theodore R.↗

Mapping of auroral X-rays from rocket overflights

Remote sensing of energetic auroral X-rays from above the emission region can provide both local and global information regarding X ray and energetic electron deposition within the middle atmosphere. However, contamination of X ray detectors by local corpuscular radiation can severely affect the scope and accuracy of the detector measurements. It is, therefore, necessary to employ techniques designed to observe X rays while rejecting the far more intense corpuscular radiation component. A suitable approach for the mapping of auroral X rays involves the employment of rockets for flights above the emission region. A description is presented of the results obtained from two rocket flights launched from Poker Flat Research Range, Alaska, during aurorally active periods in March 1978. The data were measured with the aid of scanning detectors protected from particles by broom magnet techniques.

Goldberg, R. A.↗

Imaging of spatial distributions of the millimeter wave intensity by using visible continuum radiation from a discharge in a Cs–Xe mixture. Part I: Review of the method and its fundamentals

The first part of the review is presented which is dedicated to the time-resolved method of imaging and measuring the spatial distribution of the intensity of millimeter waves by using visible continuum (VC) emitted by the positive column (PC) of a dc discharge in a mixture of cesium vapor with xenon. The review focuses on the operating principles, fundamentals, and applications of this new technique. The design of the discharge tube and experimental setup used to create a wide homogeneous plasma slab with the help of the Cs–Xe discharge at a gas pressure of 45 Torr are described. The millimeter-wave effects on the plasma slab are studied experimentally. The mechanism of microwave-induced variations in the VC brightness and the causes of violation of the local relation between the VC brightness and the intensity of millimeter waves are discussed. Experiments on the imaging of the field patterns of horn antennas and quasi-optical beams demonstrate that this technique can be used for good-quality imaging of millimeter-wave beams in the entire millimeter-wavelength band. The method has a microsecond temporal resolution and a spatial resolution of about 2 mm. Energy sensitivities of about 10 μJ/cm{sup 2} in the Ka-band and about 200 μJ/cm{sup 2} in the D-band have been demonstrated.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗