Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Power systems operations”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,351 records · Page 75

Generator Interconnection Costs to the Transmission System in non-ISO Balancing Authorities [Slides]

Electric transmission system operators—including Independent System Operators (ISOs), Regional Transmission Organizations (RTOs), and utilities—require proposed power plants to undergo a series of interconnection studies before connecting to the grid. These studies assess what transmission upgrades or new infrastructure may be necessary and assign the associated costs to the project. Lawrence Berkeley National Laboratory has compiled, aggregated, and cleaned interconnection cost data, originally for ISOs/RTOs, and now for five non-ISO Balancing Authorities: PacifiCorp, Bonneville Power Authority, Duke Energy Progress, Duke Energy Carolinas and Duke Energy Florida. Insufficient transparency in interconnection cost data may contribute to rapidly expanding interconnection queues, with active queue capacities tripling between 2020 and 2024 in the studied BAs. Most projects withdraw after receiving high interconnection cost estimates. Interconnection costs have increased since the early 2000s, with average costs for "complete" projects reaching $194/kW between 2018 and 2024. Active queue projects and withdrawn projects incur substantially higher costs, primarily due to rising network upgrade costs. Recent interconnection costs in non-ISO balancing authorities are higher than in ISO regions, potentially due to a greater willingness to pay among developers. Utility-scale solar, wind, and storage projects have interconnection costs that exceed those for natural gas. However, when focusing on projects that do not withdraw from the queue, the interconnection costs for these technologies are more similar to natural gas projects. Other key findings include: (1) Larger generation projects benefit from lower proportional interconnection costs, (2) capacity transmission service (NRIS) often requires additional network investments, and (3) projects with high network upgrade costs are often clustered geographically. The dataset includes results from 2,104 interconnection studies conducted between 2000 and 2024, covering projects that are operational, withdrawn, or still progressing through the study process. The Excel file contains (a) the complete project-level interconnection cost dataset, and (b) seven additional tabs summarizing cost metrics across dimensions such as time, market structure, cost category (point of interconnection vs. broader network upgrades), fuel type, service type (ERIS vs. NRIS), generator size, and geography.

24 POWER TRANSMISSION AND DISTRIBUTION↗

AXEAP (ARGONNE X-RAY EMISSION PACKAGE)

Argonne X-ray Emission Package (AXEAP), a singular purpose software package for processing X-ray emission (XES) images collected with a 2-dimensional position sensitive pixel array detector, has been developed. AXEAP can rapidly convert XES image files into a spectral form by applying parallel computation and unsupervised machine learning to compute vast amount of image data. Special focus has been placed on designing user-friendly-interface for processing multiple edges, non-resonant and resonant x-ray emission image analysis, in order to make data processing quick and easy. AXEAP is free software and is written in MATLAB, armed with powerful libraries and toolboxes. The software runs on all common operating systems such as Linux, Window, and Mac.

SUN, CHENGJUN↗

The Role of Heat-to-Power Technologies in Building Decarbonization

This paper presents the energy, economic, and environmental benefits associated with different heat-to-power technologies such as Thermoelectrics, Thermophotovoltaics, and Thermionics. Hybrid configurations consisting of heat pumps, heat-to-power systems, and renewable PV in cogeneration and trigeneration modes of operation will be presented. The role of such technologies in lowering the primary energy consumption, carbon dioxide emissions while improving the energy resiliency and serving the needs of underprivileged communities will be discussed. The key barriers of affordability and potential solutions for large scale implementation of these promising technologies are presented.

Cheekatamarla, Praveen↗

Electrical Substation Configuration Effect on Substation Reliability

It is crucial that the U.S. electrical grid be reliable, due to its critical role in the economy and our national defense/security. Many common tasks and industrial operations rely on proper electrical power distribution. In designing new bus systems or evaluating existing ones, the type of configuration employed affects the level of risk, reliability, maintenance, and cost involved. The present work utilizes Systems Analysis Programs for Hands-on Integrated Reliability Evaluations (SAPHIRE) to perform a probabilistic risk assessment (PRA)-based sensitivity study on substation reliability in regard to different bus configurations. This study examines single bus, main and transfer, breaker and a half, double bus/double breaker, and ring bus configurations applied to busses with different numbers of lines. The case variances, methods, and rankings presented herein can help guide bus configurations for electrical grid design/analysis in the future.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Development of a high fidelity model of the CROCUS experimental reactor

Measurements of scalar flux distributions with fine spatial and energy resolutions are needed to remedy one of the validation shortcomings of the novel neutronics full core solvers, such as MPACT and nTRACER. While a very detailed resolution of the flux can be calculated with such codes, only a limited experimental data set is available to check their accuracy. Such type of measurements are on-going at the zero power reactor CROCUS, operated at the Laboratory for Reactor Physics and System Behaviours of the EPFL, thanks to the development of advanced miniature neutron detection systems. This kind of experimental data would provide the community with a suitable benchmark for the validation of high fidelity neutronics solvers. In parallel, a multi-physics solver for steady-state and transient analysis of nuclear reactors, named GeN-Foam, has been developed. Based on the finite-volume OpenFOAM library, GeN-Foam provides us with enough flexibility to analyze non-conventional reactor geometries such as that of CROCUS. While CROCUS heterogeneities cannot be modeled by MPACT and nTRACER for the moment, GeN-Foam offers a unique opportunity to build a high fidelity model which mimics these codes' method to reach sub-pin simulation resolution. This document aims at describing the work achieved to get from the existing GeN-Foam model of the CROCUS reactor based on a structured mesh and using the neutron diffusion, the first high-fidelity model using discrete ordinates method as an approximation to neutron transport and an unstructured mesh for inter lattice water gap description and sub-pin heterogeneous modeling. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

A Cable Condition Monitoring Strategy for Safe and Reliable Plant Operation

Electrical cables provide essential functions, such as delivery of power or instrumentation signals for monitoring systems. Most cables installed in industrial applications are constructed with organic polymer insulations that can become brittle, crack, or degrade over time from exposure to harsh environmental conditions, such as elevated temperatures, moisture, vibration, mechanical shock, and radiation. This paper describes an overall strategy for assessing the health and managing the aging of cables during the operating life of an industrial facility. This strategy involves performing condition assessments and monitoring of electrical cables using both in situ and laboratory testing techniques. It includes in situ testing to identify anomalies in the circuits, such as degraded terminations, splices, connections, and degraded sections of cable insulation, as well as as-found evaluations to determine the current condition of installed cables. Furthermore, these cable condition evaluations provide important information about the current state of the cable circuits. Moreover, the test results can be used to trend/monitor age-related degradation and estimate the remaining useful life of installed cables.

36 MATERIALS SCIENCE↗

Operation and Control of Electric Vehicle Charger with Enhanced Dynamic Performance Under Non-Ideal Grid Voltage Condition

This paper presents a three-phase electric vehicle charger connected to the grid, featuring multiple boost converters on the DC side, specifically designed to ensure smooth, oscillation-free power transfer during unsymmetrical voltage sags. Precise control mechanisms are implemented on the boost converter side to regulate both voltage and current on the electric vehicle side, thereby maintaining optimal charging conditions. The control architecture for both the grid-connected and boost converter components is based on the Lyapunov energy function, which is employed to achieve superior dynamic performance and stability. The system's robustness and reliability are demonstrated through its ability to maintain stable operation and efficient power transfer despite fluctuations in grid conditions. Furthermore, the implementation of Lyapunov-based control ensures rapid response and minimal energy loss, enhancing the overall efficiency of the system. To validate the effectiveness of this approach, a comprehensive model of the system was developed and tested using MATLAB/Simulink, with detailed computer simulations conducted across various significant case studies.

DC-DC boost converter↗

A Low-Cost, Reconfigurable UWB Microwave Radar Front-End for Fine Resolution Nadir-Looking Measurements of Snow and Layered Media

This paper presents a reconfigurable, low-cost ultra-wideband microwave radar front-end and radar demonstrator designed for nadir-looking measurements of layered media (e.g. snow or vegetation) from either a fast-moving ground-based platform or a C-3 class unmanned aerial system (UAS). The radar demonstrator uses a frequency modulated continuous-wave (FMCW) architecture and can be configured to operate in either the 2-8 GHz or in the 12-18 GHz range, providing fine vertical resolution while offering a significantly reduced weight, size, and power consumption with respect to prior implementations. We have demonstrated the operation of the system in the 2-8 GHz and 12-18 GHz bands in the laboratory; in the 2-8 GHz band using a surface-based setup in Antarctica; and in the 2.6-7 GHz band on local flight tests onboard an Aurelia X6 Pro UAS equipped with 3-D printed antennas. This paper provides an overview of the radar front-end and demonstrator design and implementation and a summary of the different tests completed to document their performance.

UWB radar, UAS-borne radar, snow-probing radar.↗

Grid Strength Analysis for Integrating 30 GW of Offshore Wind Generation by 2030 in the U.S. Eastern Interconnection

Offshore wind is a key player in the transition to a decarbonized electric gird, and the United States has set ambitious goals of integrating 30 GW of offshore wind capacity by 2030 and 110 GW by 2050. To facilitate this integration, the National Renewable Energy Laboratory and the Pacific Northwest National Laboratory are conducting the Atlantic Offshore Wind Transmission Study to assess transmission solutions. To achieve the 110-GW target by 2050, meticulous planning for network expansion and resource allocation is essential; however, meeting the 2030 goals requires integrating offshore wind power with minimal system upgrades, thus necessitating a careful study of grid strength and stability. The study team developed the Automated System-wide Strength Evaluation Tool (ASSET) to assess system strength under various operating conditions and contingencies, focusing on the proposed integration of 30 GW of offshore wind power by 2030. In this paper, we provide a summary of key features of the ASSET software and results of the grid strength analysis for integrating 30 GW of offshore wind generation by 2030 in the U.S. Eastern Interconnection.

Automated System-wide Strength Evaluation Tool (AS↗

Robotics for Energy Infrastructure Construction on Earth and Beyond: Pilot Study Exploring Level 3-4 Semi-Autonomous Installation of a Reduced-Scale Photovoltaic Power Plant Prototype: Preprint

There is a growing need to build energy infrastructure at massive scale on both Earth and in space. On Earth, increasing electricity demand from applications such as AI data centers is driving rapid expansion of power systems, while in space, long-duration missions such as lunar operations require reliable and resilient energy infrastructure that can be deployed quickly. These needs outpace the capabilities of conventional construction methods. Robotic construction offers a path to faster, lower-cost, and more consistent deployment, yet most existing approaches focus on automating individual tasks rather than end-to-end assembly. The Industrialized Construction Innovation (ICI) team at the National Laboratory of the Rockies (NLR), in collaboration with the Colorado School of Mines, has been investigating robotics and automation strategies for rapid end-to-end energy infrastructure construction. This paper presents a pilot study demonstrating level 3-4 semi-autonomous, end-to-end robotic assembly of a reduced-scale photovoltaic power plant prototype under terrestrial conditions. The approach combines hardware redesign of photovoltaic components for robotic compatibility, discrete-event and physics-based robotic simulations in synthetic environments, and sim-to-real deployment to execute end-to-end robotic assembly of[NM1.1][NM1.2] tracking components, structural members, photovoltaic modules, and embedded electrical connections. The pilot identifies key limitations like tolerance management, perception and localization, end effector capability, fastening methods, and multi-physics simulation fidelity, that must be addressed to enable end-to-end robotic assembly of full-scale energy infrastructure. The study highlights how these insights inform scaling strategies for terrestrial energy infrastructure and adaptation to unstructured and extreme environments, including off-world scenarios such as robotic assembly of vertical tall lunar towers.

14 SOLAR ENERGY↗

Transactive Implementation of Decentralized Electricity Market for Grid-Edge Systems

The electricity landscape is evolving towards more decentralized approaches due to the proliferation of distributed energy resources and the participation of increasingly smart consumers and producers (prosumers). Recent advances in information and communication technologies and smart metering, provides strategic opportunities for “prosumers” to reform their conventional energy practices towards more consumer-centric economies. From an operational perspective, managing power distribution networks is becoming more difficult with such active grid-edge systems providing limited to no visibility or control. Transactive Energy (TE) has been emerging as a key enabler towards effectively and efficiently integrating prosumers into competitive electricity markets. This work presents a transactive implementation of community-centric markets. A co-simulation framework is developed for evaluating the proposed market structure with high-fidelity models. Case studies on the IEEE-123 node test system demonstrate that community-centric transactive markets can enable communities of prosumers to operate collaboratively as grid-edge systems. The potential benefits of implementing community-centric TE systems are also illustrated.

transactive, microgrids, centralized market operat↗

Distribution Operations: The Evolution of Distributed Energy Resources [Guest Editorial]

Utilities around the world are experiencing change with the increasing digitalization of their systems and those of their customers. Efforts to decarbonize the electric power system have led to growth in renewable energy resources, particularly distributed energy resources (DERs), such as generation, storage, and flexible load, both in front of and behind the meter. As this change occurs in any given utility service area, new tools, such as advanced distribution management systems (ADMSs), are needed to manage utility operations, planning, and business issues, some of which are discussed here.

distributed energy resources, DER, decarbonize, re↗

Valuing Maintenance Strategies for Fusion Plants as Part of a Future Electricity Grid

Scheduled maintenance is likely to be lengthy and therefore consequential for the economics of fusion power plants. The maintenance strategy that maximizes the economic value of a plant depends on internal factors such as the cost and durability of the replaceable components, the frequency and duration of the maintenance blocks, and the external factors of the electricity system in which the plant operates. Here, this paper examines the value of fusion power plants with various maintenance properties in a decarbonized United States Eastern Interconnection circa 2050. Seasonal variations in electricity supply and demand mean that certain times of year, particularly spring to early summer, are best for scheduled maintenance. Seasonality has two important consequences. First, the value of a plant can be 15% higher than what one would naively expect if value were directly proportional to its availability. Second, in some cases, replacing fractions of a component in shorter maintenance blocks spread over multiple years is better than replacing it all at once during a longer outage, even through the overall availability of the plant is lower in the former scenario.

power plant, maintenance, seasonality, electricity↗

Adaptable Monitoring Package Development and Deployment: Lessons Learned for Integrated Instrumentation at Marine Energy Sites

Integrated instrumentation packages are an attractive option for environmental and ecological monitoring at marine energy sites, as they can support a range of sensors in a form factor compact enough for the operational constraints posed by energetic waves and currents. Here we present details of the architecture and performance for one such system—the Adaptable Monitoring Package—which supports active acoustic, passive acoustic, and optical sensing to quantify the physical environment and animal presence at marine energy sites. we describe cabled and autonomous deployments and contrast the relatively limited system capabilities in an autonomous operating mode with more expansive capabilities, including real-time data processing, afforded by shore power or in situ power harvesting from waves. Across these deployments, we describe sensor performance, outcomes for biological target classification algorithms using data from multibeam sonars and optical cameras, and the effectiveness of measures to limit biofouling and corrosion. On the basis of these experiences, we discuss the demonstrated requirements for integrated instrumentation, possible operational concepts for monitoring the environmental and ecological effects of marine energy converters using such systems, and the engineering trade-offs inherent in their development. Overall, we find that integrated instrumentation can provide powerful capabilities for observing rare events, managing the volume of data collected, and mitigating potential bias to marine animal behavior. These capabilities may be as relevant to the broader oceanographic community as they are to the emerging marine energy sector.

16 TIDAL AND WAVE POWER↗

Assessing Dynamic Behaviors in Converter- Dominated Power Systems via RMS and EMT Simulations: A Study of Hawaii’s NELHA Microgrid

The transition from conventional power systems to converter-based microgrids has significantly advanced sustainability, clean energy integration, and operational reliability. However, this paradigm shift introduces operational challenges due to the intermittent nature of renewable energy sources and the non-linear characteristics of power electronic loads, inducing voltage fluctuations and harmonic distortions that complicate voltage and frequency regulation. Accurate dynamic modeling is hypothesized to be critical for capturing such effects, enabling reliable simulation and control strategy development. This study introduces an innovative dynamic modeling framework for a real-world converter-based microgrid, utilizing both root mean square (RMS) and electromagnetic transient (EMT) simulation methods. The microgrid was modeled in DIgSILENT PowerFactory, with simulations calibrated against high-resolution field measurements from SEL-735 power quality meters. Results show that RMS simulations effectively characterize steady-state dynamics, while EMT simulations are essential for capturing high-frequency transients and non-linear effects from photovoltaic inverters and variable frequency drives (VFDs). This complementary approach provides a comprehensive understanding of microgrid behavior, providing critical insights for improving simulation accuracy, advancing protection schemes, and improving resilience in future low-inertia power networks.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Incorporating energy justice and equity objectives in power system models

Ensuring an equitable energy transition requires models and tools that can account for equity and energy justice goals. Power system models (PSMs) are widely used throughout industry, government, and academia to simulate or optimize the operations and planning of current and future electricity systems under different scenarios, parameter assumptions and policy frameworks. These models are important tools that allow users to understand how the power system may evolve under different future conditions, but importantly, they are also used to inform policy implementation and investment decisions across all aspects of the power system. However, existing models seldom include energy justice considerations and therefore energy justice priorities are not reflected in the policies and other decision-making processes that are informed by these models. The purpose of this review is to provide a framework that energy modelers can draw upon to integrate energy justice and equity goals into PSMs. To this end, 99 papers that examine the intersection of energy justice and power system models are summarized and ten core aspects of the power system that can impact energy justice outcomes, and therefore require new modeling approaches, are identified. This review then establishes key current practices, challenges, and opportunities associated with capturing energy justice considerations in power system models across these ten aspects. This review concludes by proposing four key research directions that should be pursued to improve the representation of energy justice and equity in power system modeling. Finally, this review also addresses challenges raised by United Nations Sustainable Development Goal 7, which aims to ensure affordable energy access to everyone and Sustainable Development Goal 13, which aims to take urgent action to address climate change.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Integration of Energy Storage in Fossil Energy Power Plants (ES-FE) Market Analysis

This analysis consists of identifying the economic signals for the integration of ES-FE concepts in major Independent System Operators (ISOs), such as Mid-Continent (MISO), Electric Reliability Council of Texas (ERCOT), California (CAISO), and Pennsylvania, Jersey, Maryland Power Pool (PJM). This piece of work came from our interest in understanding how and at what level an electricity market would renumerate a fossil energy power plant that integrates energy storage, meaning a fossil power plant that adds any type of energy storage to their power plant.

Pena-Cabra, Ivonne A.↗

Power System Modeling for the Study of High Penetration of Distributed Photovoltaic Energy

Many conventional power systems are evolving due to the growth of renewable energy and distributed energy resources (DERs). Modeling the interplay of transmission and distribution systems is critical to analyze how DERs impact a system’s conventional operation and which electric infrastructure improvements are needed to achieve a balance between centralized generation and DERs. This article describes the process, tools, and resources used to model electric power systems with a centralized infrastructure in an isolated context and limited access to actual utility data. Photovoltaic systems installed on residential rooftops were the main design option. This work broadened the typical power system modeling to include planning and social considerations. This integrative engineering-social method allows for interdisciplinary teams to work in the development of a model as part of broader design goals for a renewable-dominant energy system. The Puerto Rico electric power system was used as a case study to demonstrate the process. The integrative engineering-social perspective in developing the model and the actions to manage data limitations are aspects that could be followed in other locations with aggressive renewable energy goals and where utility data are not readily available.

Cuello-Polo, Gustavo↗