Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Power system control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,351 records · Page 75

Tunnel junction-enabled monolithically integrated GaN micro-light emitting transistor

GaN/InGaN microLEDs are a very promising technology for next-generation displays. Switching control transistors and their integration are key components in achieving high-performance, efficient displays. Monolithic integration of microLEDs with GaN switching devices provides an opportunity to control microLED output power with capacitive (voltage)-controlled rather than current-controlled schemes. This approach can greatly reduce system complexity for the driver circuit arrays while maintaining device opto-electronic performance. In this work, we demonstrate a 3-terminal GaN micro-light emitting transistor that combines a GaN/InGaN blue tunneling-based microLED with a GaN n-channel FET. Further, the integrated device exhibits excellent gate control, drain current control, and optical emission control. This work provides a promising pathway for future monolithic integration of GaN FETs with microLED to enable fast switching, high-efficiency microLED display and communication systems.

42 ENGINEERING↗

Optimisation of the Kaplan hydropower system via PID 2 and digital twin

Here, this paper proposes a proportional–integral-double–derivative (PID 2 ) optimisation method for the Kaplan hydropower system by building a digital twin. The study first uses one multilayer perceptron (MLP) to model the hydroturbine dynamic and then adopts three connected MLPs to model the generator dynamic, both in an open-loop fashion. Inspired by stochastic distribution control (SDC) theory, we regard the training of the turbine's neural network model as a process control problem, and we propose minimising entropy loss to update the network parameters. The next step is to build the digital twin by connecting the neural network models with a PID 2 controller and a lead-lag exciter and run the whole model in a closed-loop fashion. After that, a binary search approach is applied to optimise the PID 2 parameters based on the obtained digital twin model. The simulation results show that the proposed method can reduce the mean square tracking error by more than 90%. Furthermore, the method is extended to jointly optimise the PID 2 controller and excitation system gains through multiobjective optimisation, leveraging Pareto frontier analysis to balance active power and voltage tracking performance. Simulation results confirm the effectiveness of the proposed method, achieving a 83.46% reduction in relative mean square error of active power, a 47.13% reduction in terminal voltage tracking error, and an 82.78% improvement in the overall scalarized objective.

Hydropower system↗

Identification and control of the exhaust using gas perturbations in the DIII-D tokamak

This paper presents perturbative experiments that enable the validation and development of control-oriented models for exhaust control. We identify the response of the divertor plasma and scrape-off layer in the DIII-D tokamak to deuterium and nitrogen multi-sine perturbations, in favorable and unfavorable field directions for H-mode access. We obtained good signal-to-noise ratios in the 1–10 Hz frequency range by measuring Balmer-alpha, Lyman-alpha, and N 4+ line emission, radiated power, and neutral pressure. We find a similar phase response across gas species and magnetic field directions, while the gain response is nonlinear. With these experiments, we identify a control-oriented model to design a divertor radiated power controller to track specified reference waveforms in conjunction with resonant magnetic perturbations. Although the physics basis for compatibility between detachment and resonant magnetic perturbation edge-localized mode suppression remains to be demonstrated, the present results provide a robust controller that represents a promising step toward future joint control strategies.

detachment control↗

An Intelligent Power Electronic System for Secondary Use Batteries

This paper presents a plug-and-play power electronic system for integration of multiple energy storage system technologies. The system uses a communication and control architecture with individual developed modules to support scaling to larger systems for the electric grid. An optimization framework is also presented to demonstrate the functionality of the system. This system is shown to work in hardware with a constructed testbed to demonstrate different use cases and systems. Results are presented for a full efficiency cycle test.

Starke, Michael↗

Foundations for the Future Power System: Inverter-Based Resource Interconnection Standards

As power systems evolve to become reliant on solar, wind, batteries, and other inverter-based resources (IBRs), it is essential that those resources meet certain minimum performance and capability criteria designed to ensure the power system operates stably and reliably. Because those criteria, as enshrined in interconnection standards, take years to develop and are very long lived, they need to account for not only the present state of the power system but also its expected future state over the lifetime of the power plants to which they will apply. In addition, they need to be specific enough to ensure reliability without over specifying and, thereby, impeding innovation. Because power systems are shifting rapidly from a state where IBRs make up a small to medium portion of generation to one where the generation will, at times, come predominantly from IBRs, interconnection standards are especially challenging to develop today. Good interconnection standards can make the power system more reliable and less costly to operate, whereas poorly designed standards can lead to major problems, like the famous German 50.2-Hz problem, which introduced a risk of losing many gigawatts of solar on a frequency excursion and resulted in many IBRs being retrofitted at great cost to mitigate a major system reliability risk. Readying the power system by specifying forward-looking technical minimum functional capabilities for IBRs can be an effective approach to avoid future retrofits.

data models↗

Autonomous Voltage Response for Distributed Energy Resources

An implementation of stable droop voltage response for distributed energy resources (DER) is described. The key point is to use a new “autonomously adjusting reference voltage” as described in IEEE Standard 1547-2018. Examples include battery voltage response, a photovoltaic inverter at the end of a long secondary circuit, and 18 photovoltaic inverters on a distribution lateral. Default inverter settings are proposed for DER that would mitigate voltage fluctuations, with or without communications.

Automatic voltage control, distributed power gener↗

Developing of Quaternary Pumped Storage Hydropower for Dynamic Studies

Quaternary pumped storage hydropower (Q-PSH) technology, as one of the new advanced-PSH technology, has been developed by taking advantage of Conventional-PSH (C-PSH) and Adjustable Speed-PSH (AS-PSH). By combining adjustable-speed pump unit and conventional hydropower turbine unit in the quaternary configuration, Q-PSH has the more competitive capability of providing fast power support in the future high renewable penetrated power system. Acting as energy storage (ES), Q-PSH provides promising power supply to deal with the uncertainty and variability from renewable energy generation. This paper focuses on the dynamic modeling of Q-PSH technology employing full-converter machine and the impact of Q-PSH on the frequency response in a system. The detailed model of Q-PSH is developed and implemented in the IEEE 14-bus system based on GE Positive Sequence Load Flow (PSLF) platform, which captures the dynamic of multiple operation modes, especially hydraulic short-circuit (HSC) operation mode. Several cases are set up to reveal the advantages of Q-PSH technology when power electronic based renewable energy generation is deployed in the system. Sensitivity studies of the controller in pump governor show the impact of parameters in pump response performance. The comparison case illustrates the impact of frequency response provided by the Q-PSH in the system.

dynamic modeling↗

CyRRL (Cyber Resilient Reinforcement Learning for grid voltage control) [SWR-24-115]

This codebase contains a multi-agent, actor-critic reinforcement learning implementation for cyber-resilient grid voltage control. It uses a 123-bus OpenDSS system as the environment, with three-phase power flow translating nodal power injections into solved nodal voltages. The reward function penalizes deviations from nominal voltage as well as reactive power dispatch, while encouraging agents to take actions that result in fast convergence to nominal conditions. The codebase models false data injection attacks and includes functionality for training, testing, hyper-parameter tuning, and visualization.

Murphy, Sinnott [National Renewable Energy Laborat↗

Development of Miniaturized High-Temperature Multi-Process Monitoring System

The main objective of this research program is to design, manufacture, and demonstrate a miniaturized, multi-process, monitoring system (mMPMS) for boiler condition management and easy system deployment to obtain a higher spatial resolution. This system will facilitate a Condition-Based Maintenance (CBM) philosophy that actively monitors the health of assets to predict and prevent failures and maximize availability and generating capacity at a reduced cost. CBM systems can provide boiler data that the advanced process control (APC) system can utilize for plant performance optimization, which is increasingly relevant as coal power plants shift from predominantly base-load operation to predominantly transient operation involving large load swings.

20 FOSSIL-FUELED POWER PLANTS↗

Evaluation of Digital Twin Modeling and Simulation

A digital twin has intelligent modules that continuously monitor the condition of the individual components and the whole of a system. Digital twins can provide nuclear power plants (NPP) operators an unprecedented level of monitoring, control, supervision, and security by contributing a greater volume of data for more comprehensive data analysis and increased accuracy of insights and predictions for decision making throughout the entire NPP lifecycle. NPP operators and managers have historically relied on limited, second hand or incomplete data. With proper implementation, digital twins can provide a central hub of all intel that allows for a multidisciplinary view of an NPP. This equips operators and managers with the ability to have more information, context, and intel that can be used for greater granularity during planning and decision making. Digital twins can be used in many activities as the technology has many different concepts surrounding it. From the various definitions of a digital twin within the industry, digital twins can be differentiated by levels of integration/automation. The three main models include digital model, digital shadow, and digital twin. Digital twins offer many potential advancements to the nuclear industry that could reduce costs, improve designs, provide safer operation, and improve their overall security.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

High-Fidelity Analysis of EV Integration on Real Utility Feeders in Colorado

Residential electric vehicle (EV) charging has the potential to alter long-held assumptions on load characteristics impacting distribution grid planning, operations, and design standards. This study identifies analysis and control methods to increase the affordability of residential EV charging both for Xcel Energy and their customers. The project also provides solutions for more reliable grid interconnection that can support a reliable utility business model prepared for increasing EV charging load in the coming years. For this project, we referenced Level 2 alternating current (AC) onboard charging profiles for various vehicle models and high-fidelity charging data collected at the experimental setup established at the EV Research Infrastructure Laboratory at the National Renewable Energy Laboratory (NREL). Next, we developed EV adoption models for 2030 and 2040 for the Boulder and Aurora regions in Colorado. Moreover, we evaluated different smart charging control algorithms and compared their performance. We developed time-of-use (TOU)-based and grid-aware active EV charging control methods and integrated them within the study region to understand field impacts. Diving deeper, we selected 10 feeders in Boulder and Aurora for high-fidelity grid modeling down to the house level. We executed detailed grid analysis comparing the smart charge management (SCM) algorithms we developed. Finally, we created a novel tool, Electric Vehicle Infrastructure--Distribution System Integration Tool (EVI-DiST), to integrate all the approaches in a single software environment to provide easy integration, fast simulation, and detailed evaluation capability for utility engineers and other stakeholders.

33 ADVANCED PROPULSION SYSTEMS↗

Power Prediction of Airborne Wind Energy Systems Using Multivariate Machine Learning

Kites can be used to harvest wind energy at higher altitudes while using only a fraction of the material required for conventional wind turbines. In this work, we present the kite system of Kyushu University and demonstrate how experimental data can be used to train machine learning regression models. The system is designed for 7 kW traction power and comprises an inflatable wing with suspended kite control unit that is either tethered to a fixed ground anchor or to a towing vehicle to produce a controlled relative flow environment. A measurement unit was attached to the kite for data acquisition. To predict the generated tether force, we collected input–output samples from a set of well-designed experimental runs to act as our labeled training data in a supervised machine learning setting. We then identified a set of key input parameters which were found to be consistent with our sensitivity analysis using Pearson input–output correlation metrics. Finally, we designed and tested the accuracy of a neural network, among other multivariate regression models. The quality metrics of our models show great promise in accurately predicting the tether force for new input/feature combinations and potentially guide new designs for optimal power generation.

17 WIND ENERGY↗

Attacking the IEC-61131 Logic Engine in Programmable Logic Controllers in Industrial Control Systems

In industrial control systems (ICS), programmable logic controllers (PLCs) directly monitor and control a physical process such as nuclear power plants, gas pipelines, and water treatment. They are equipped with a control logic written in IEC-61131 languages (e.g., ladder logic and structured text) that defines how a PLC should control a physical process. A PLC's control logic is a usual target of a cyberattack to sabotage a physical process. For instance, Stuxnet targets a control logic of a Siemens S7-300 PLC to damage a nuclear facility's centrifuges. The existing attacks in the literature generally focus only on injecting malicious control logic into a PLC. This paper presents a new dimension of control logic attacks that target the control logic engine (responsible for running a control logic) of a PLC. It demonstrates that a cyberattack can disable the control logic engine successfully by exploiting inherent PLC features such as program mode and starting/stopping engine. We develop two novel case studies on control logic engine attacks by employing the MITRE ATT\&CK knowledge base on the real-world PLCs used in industry settings, i.e., 1) Schweitzer Engineering Laboratory (SEL)'s Real-Time Automation Controller (SEL-3505 RTAC) equipped with security features such as encrypted traffic and device-level access control, and 2) traditional PLCs, i.e., Schneider Electric's Modicon M221, Allen-Bradley's MicroLogix 1400 and 1100 that do not have security features. The case studies present the internals of the logic engine attacks and facilitate the ICS research community and industry to understand the attack vectors on the control logic engine. We evaluate the effectiveness of the control engine attacks on a power substation, a 4-floor elevator, and a conveyor belt to demonstrate their real-world impact of halting a physical process.

Ali qasim, Syed↗

How the NRC modernized its digital I&C infrastructure and where it goes from here

The NRC first formally developed infrastructure for the review of digital instrumentation and control (I&C) systems in the 1990’s. Although, the current U.S. fleet of nuclear power plants were originally designed and constructed with analog systems, the U.S. nuclear industry has for more that thirty years been working to upgrade these older systems with modern digital systems. Digital systems have many advantages but also pose different engineering challenges and need to be reviewed by the Nuclear Regulatory Commission (NRC) in a different way. Because of this the NRC started looking at its regulatory infrastructure to see if changes needed be made to support the expanded safe use of digital systems in nuclear power plants. Several efforts in the 1990’s included a review by the National Academies’ National Research Council, a review of the impact of potential new digital systems by the NRC staff as a result of advanced reactor designs and the NRC staff’s update to the I&C section of the Standard Review Plan (SRP) (Ref 1).

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

System and method of making an enhanced cast iron crankshaft

A method and system for manufacturing a cast iron crankshaft for a vehicle are provided. The system comprises a molding unit arranged to form a negative sand cast mold of the cast iron crankshaft. The mold comprising at least one molded cavity having a pattern with dimensions of the cast iron crankshaft. The system further comprises a feeding mechanism comprising a riser having a connector through which molten metallic material flows to the cast mold. The feeding mechanism feeds the molten metallic material at a riser connection angle in the at least one mold cavity. The riser connection angle corresponds to a connector modulus. The connector modulus is 20% greater than a cast modulus. The riser geometry corresponds to a riser modulus. The riser modulus is 20% greater than the connector modulus. The system further comprises a furnace, a cooling area, a separation unit, a controller and a power source.

Wang, Liang↗

Systems and methods for controlling an industrial asset in the presence of a cyber-attack

Systems and methods are provided for the control of an industrial asset, such as a power generating asset. Accordingly, a cyber-attack model predicts a plurality of operational impacts on the industrial asset resulting from a plurality of potential cyber-attacks. The cyber-attack model also predicts a corresponding plurality of potential mitigation responses. In operation, a cyber-attack impacting at least one component of the industrial asset is detected via the cyber-attack neutralization module and a protected operational impact of the cyber-attack is identified based on the cyber-attack model. The cyber-attack neutralization module selects at least one mitigation response of the plurality of mitigation responses based on the predicted operational impact and an operating state of the industrial asset is altered based on the selected mitigation response.

D'Amato, Fernando Javier↗

RADIANCE Executive Summary

Microgrids are gaining attention from organizations and cities because of their potential reliability and resilience benefits, especially in remote geographic areas: Microgrids can provide local power during emergencies, and they can reduce the costs of imported fuel by reducing overall fuel use. But the complexities and novelties of microgrid technologies are often barriers to deployment that require testing and validation to overcome. This report describes the testing, validation, and deployment of microgrid technologies in Cordova, Alaska, completed through the U.S. Department of Energy (DOE) Grid Modernization Laboratory Consortium (GMLC) project Resilient Alaskan Distribution system Improvements using Automation, Network analysis, Control, and Energy storage (RADIANCE).

ARIES↗

Validation of Power Distribution Models using Load Flow Analysis in an ADMS Environment

Electric utilities are facing the need for better monitoring, analysis, and control of their distribution systems. An accurate mathematical model is a key to both the development of cutting-edge, scalable model-based algorithms and the assessment of emerging technologies such as distributed energy resources (DER) for grid planning and operation. However, the constantly evolving nature of power distribution systems poses challenges to maintaining accurate models. In this paper, we propose a novel load flow based approach to validate power distribution models. Networked equipment models described according to the Common Information Model (CIM) standard and a measurement model are used to formulate the distribution load flow problem. First, a system admittance matrix (Ybus) is derived from device-level CIM parameters. Next, the operational parameters (dynamic Ybus and nodal injections) are extracted from the measurement model using sensor configuration and equipment state. An iterative power flow method is then used to compute nodal voltages and branch flows that are compared against the measurement data to find any inconsistencies in the networked equipment model. This approach is implemented within GridAPPS-D, an open-source standards-based platform for advanced distribution management system (ADMS) application development, and demonstrated on the IEEE 13-bus, 123-bus, and 8500-node test feeders.

Common information model, model validation, power ↗