Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Power Grid Operations”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,351 records · Page 75

Understanding the Grid

The electric power grid has been rightly celebrated as the single most important engineering feat of the 20th century. The grid powers our homes, offices, hospitals, and schools; and, increasingly, it powers our favorite devices from smartphones to HDTVs. With those and other modern innovations and challenges, our grid will need to evolve. Grid modernization efforts will help the grid make full use of today’s advanced technologies and serve our needs in the 21st century. While the vast majority of upgrades are implemented by private sector energy companies that own and operate the grid, DOE has been investing in technologies that are revolutionizing the way we generate, store and transmit power.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Dynamic Restoration Strategy for Distribution System Resilience Enhancement

In electric power distribution systems, distributed energy resources (DERs) can act as controllable power sources and support utility operators to minimize power outages after extreme weather events (e.g., hurricane, earthquake, wildfire) and thus help enhance the grid's resilience. Meanwhile, the influences of extreme events and the capabilities of DERs are dynamic and difficult to predict. Hence, the desired distribution system restoration strategy should be able to evolve according to real-time fault/dis-turbance information and the availability of DERs. In this paper, we propose a new dynamic restoration strategy for distribution systems to enhance system resilience against potential hazards. An efficient reconfiguration algorithm is developed to eliminate the use of integer variables to relieve the computational burden. Model predictive control is implemented to adjust the system topology and DER operation set points based on the updated fault information and DER forecasts. The effectiveness of the proposed restoration model in enhancing distribution system resilience is validated through an IEEE 123-bus test system. Simulation results also validate that the proposed restoration model can mitigate the occurrence of unexpected events and the fluctuations of DERs.

distributed energy resources (DERs)↗

TECHNCIAL REPORT

The outcomes of these upgrades include an estimated savings to the City and the power grid of 720 kilowatts in peak energy load. This outcome includes the benefit of lower operating costs for the City, conservation of energy resources and increased availability of energy to the grid during peak times of energy use. The goals and objectives of the HVAC upgrades are to replace equipment as old as twenty-three (23) years in five different facilities. The project will upgrade some facilities from SEER ratings of 9 to SEER ratings of 14 at a savings of 556 kilowatt hours per ton (savings depends on specific size of the system). In addition to these objectives, the project will also install comprehensive HVAC control systems to maximize the efficiency of all HVAC upgrades. The expected outcomes of these upgrades emphasize savings capture; it is anticipated to save the City’s 42% in space heating and cooling costs.

24 POWER TRANSMISSION AND DISTRIBUTION↗

FY25 Electric Grid Security Annual Report

Sandia’s Electric Grid Security program advances a national vision of energy dominance and accessibility, while applying our national security -emphasis on ensuring of a secure, resilient, and affordable electric system for all users. Our achievements reflect a strategic approach combining technology development; modeling, simulation, and data analytics; and partnered demonstrations and outreach to further the adoption of advanced grid and storage technologies. Our FY25 efforts leverage the strengths of our partnerships—spanning Sandia’s core science and technology competencies as well as external technology leaders—to develop the solutions today which enable the grid of tomorrow. Key accomplishments in this report that support our strategy span our technical program areas and include: • New open-source analytical tools for systems -level planning and optimization, including significant advances to the QuESt analytical environment; • Further advancement of artificial intelligence and machine learning to enhanced grid operations and planning as we rise to the challenge of new large loads; • Development of solid-state power conversion technologies and a new medium-voltage research lab; • New technologies to assess wildfire vulnerabilities and mitigate potential impacts; • Advanced applications of new cybersecurity technologies with industry partners; • Contributions to understanding the impacts of electromagnetic pulses and geomagnetic disturbances on grid components; and • Digital twin development for hybrid microgrids with multiple generators, storage, and loads. This report indicates key areas of research and engagement and summarizes the impact of Sandia’s contributions through notable accomplishments, journal publications, patents, and technical conferences and presentations. It is provided with the hope that readers discover ways we can further team to create our modern grid and apply the outcomes of our efforts. The bulk of work described herein is funded by several offices within the U.S. Department of Energy (USDOE), including the Office of Electricity (OE); Cybersecurity, Energy Security, and Emergency Response (CESER); former offices such as the Office of Energy Efficiency and Renewable Energy (EERE), the Grid Deployment Office (GDO), the Office of Clean Energy Demonstrations (OCED), and other key programs at USDOE. As we continue to state in these annual reports, the contributors to our successes are too numerous to name here, though our team wishes to express our deep gratitude to the numerous program and project sponsors at the US Department of Energy, who often function equally as technical collaborators; our many partners in industry, academia, utilities, and other national labs; and fellow researchers and business partners at Sandia whose leadership and creativity have enabled the accomplishments described herein.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Domed, 40-cm-Diameter Ion Optics for an Ion Thruster

Improved accelerator and screen grids for an ion accelerator have been designed and tested in a continuing effort to increase the sustainable power and thrust at the high end of the accelerator throttling range. The accelerator and screen grids are undergoing development for intended use as NASA s Evolutionary Xenon Thruster (NEXT) a spacecraft thruster that would have an input-power throttling range of 1.2 to 6.9 kW. The improved accelerator and screen grids could also be incorporated into ion accelerators used in such industrial processes as ion implantation and ion milling. NEXT is a successor to the NASA Solar Electric Propulsion Technology Application Readiness (NSTAR) thruster - a state-of-the-art ion thruster characterized by, among other things, a beam-extraction diameter of 28 cm, a span-to-gap ratio (defined as this diameter divided by the distance between the grids) of about 430, and a rated peak input power of 2.3 kW. To enable the NEXT thruster to operate at the required higher peak power, the beam-extraction diameter was increased to 40 cm almost doubling the beam-extraction area over that of NSTAR (see figure). The span-to-gap ratio was increased to 600 to enable throttling to the low end of the required input-power range. The geometry of the apertures in the grids was selected on the basis of experience in the use of grids of similar geometry in the NSTAR thruster. Characteristics of the aperture geometry include a high open-area fraction in the screen grid to reduce discharge losses and a low open-area fraction in the accelerator grid to reduce losses of electrically neutral gas atoms or molecules. The NEXT accelerator grid was made thicker than that of the NSTAR to make more material available for erosion, thereby increasing the service life and, hence, the total impulse. The NEXT grids are made of molybdenum, which was chosen because its combination of high strength and low thermal expansion helps to minimize thermally and inertially induced deflections of the grids. A secondary reason for choosing molybdenum is the availability of a large database for this material. To keep development costs low, the NEXT grids have been fabricated by the same techniques used to fabricate the NSTAR grids. In tests, the NEXT ion optics have been found to outperform the NSTAR ion optics, as expected.

Soulas, George C.↗

Scheduler Modeling of IBR Plants for Providing Ancillary Services [SWR-25-16]

Inverter-based resources (IBRs) have been integral components of modern power systems and their capability in providing grid services have been widely studied. To promote the deployment of IBR grid services in real utility operation, this software proposes a scheduler model for IBRs. The energy and reserve are co-optimized in day-ahead, various ancillary services, including operating reserve provision, peak load reduction, voltage regulation and power factor control are integrated in the model.

Wang, Xiaofei [National Renewable Energy Laborator↗

Passive Islanding Detection of Inverter-Based Resources in a Noisy Environment

Islanding occurs when a load is energized solely by local generators and can result in frequency and voltage instability, changes in current, and poor power quality. Poor power quality can interrupt industrial operations, damage sensitive electrical equipment, and induce outages upon the resynchronization of the island with the grid. This study proposes an islanding detection method employing a Duffing oscillator to analyze voltage fluctuations at the point of common coupling (PCC) under a high-noise environment. Unlike existing methods, which overlook the noise effect, this paper mitigates noise impact on islanding detection. Power system noise in PCC measurements arises from switching transients, harmonics, grounding issues, voltage sags and swells, electromagnetic interference, and power quality issues that affect islanding detection. Transient events like lightning-induced traveling waves to the PCC can also introduce noise levels exceeding the voltage amplitude by more than seven times, thus disturbing conventional detection techniques. The noise interferes with measurements and increases the nondetection zone (NDZ), causing failed or delayed islanding detection. The Duffing oscillator nonlinear dynamics enable detection capabilities at a high noise level. The proposed method is designed to detect the PCC voltage fluctuations based on the IEEE standard 1547 through the Duffing oscillator. For the voltages beyond the threshold, the Duffing oscillator phase trajectory changes from periodic to chaotic mode and sends an islanded operation command to the inverter. The proposed islanding detection method distinguishes switching transients and faults from an islanded operation. Experimental validation of the method is conducted using a 3.6 kW PV setup.

Energy & Fuels↗

Introduction to Grid Forming Inverters: A Key to Transforming our Power Grid [Slides]

A grid-forming (GFM) inverter-based resource (IBR) controls maintain an internal voltage phasor that is constant or nearly constant in the sub-transient to transient time frame. This definition means that the GFM IBR will nearly immediately respond to changes in the external system and attempt to maintain IBR control during challenging network conditions to maintain grid stability. In GFM IBR, the voltage phasor is controlled to maintain synchronism with other devices in the grid while regulating the active and reactive power appropriately to support the grid. This contrasts with conventional GFL IBR controls wherein immediately after a disturbance (0-5 cycles), within the normal operating range of voltage, the output current phasor magnitude and angle remain unchanged, and the current phasor begins changing only within the transient time frame (tens of cycles) to strictly control the active and reactive power being injected into the network. This presentation gives an introduction to GFM IBR and presents the current state of the art in this area.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Performance Evaluation of the Prototype Model NEXT Ion Thruster

The performance testing results of the first prototype model NEXT ion engine, PM1, are presented. The NEXT program has developed the next generation ion propulsion system to enhance and enable Discovery, New Frontiers, and Flagship-type NASA missions. The PM1 thruster exhibits operational behavior consistent with its predecessors, the engineering model thrusters, with substantial mass savings, enhanced thermal margins, and design improvements for environmental testing compliance. The dry mass of PM1 is 12.7 kg. Modifications made in the thruster design have resulted in improved performance and operating margins, as anticipated. PM1 beginning-of-life performance satisfies all of the electric propulsion thruster mission-derived technical requirements. It demonstrates a wide range of throttleability by processing input power levels from 0.5 to 6.9 kW. At 6.9 kW, the PM1 thruster demonstrates specific impulse of 4190 s, 237 mN of thrust, and a thrust efficiency of 0.71. The flat beam profile, flatness parameters vary from 0.66 at low-power to 0.88 at full-power, and advanced ion optics reduce localized accelerator grid erosion and increases margins for electron backstreaming, impingement-limited voltage, and screen grid ion transparency. The thruster throughput capability is predicted to exceed 750 kg of xenon, an equivalent of 36,500 hr of continuous operation at the full-power operating condition.

Herman, Daniel A.↗

Power Converter Control Algorithm Design and Simulation for the NREL Next-Generation Drivetrain: July 8, 2013 - January 7, 2016

The National Renewable Energy Laboratory (NREL) and NREL Next-Generation Drivetrain Partners are developing a next-generation drivetrain (NGD) design as part of a Funding Opportunity Announcement award from the U.S. Department of Energy. The proposed NGD includes comprehensive innovations to the gearbox, generator, and power converter that increase the gearbox reliability and drivetrain capacity, while lowering deployment and operation and maintenance costs. A key task within this development effort is the power converter fault control algorithm design and associated computer simulations using an integrated electromechanical model of the drivetrain. The results of this task will be used in generating the embedded control software to be utilized in the power converter during testing of the NGD in the National Wind Technology Center 2.5-MW dynamometer. A list of issues to be addressed with these algorithms was developed by review of the grid interconnection requirements of various North American transmission system operators, and those requirements that presented the greatest impact to the wind turbine drivetrain design were then selected for mitigation via power converter control algorithms.

17 WIND ENERGY↗

Coordinated Frequency Regulation in Grid-Forming Storage Network via Safety-Consensus

Inverter-based storages are poised to play a prominent role in future power grid with massive renewable generation. Grid-forming inverters (GFMs) are emerging as a dominant technology with synchronous generators (SG)-like characteristics through primary control loops. Advanced secondary-layer control schemes, e.g., consensus algorithms, allow GFM-interfaced storage units to participate in frequency regulations and restore nominal frequency following grid disturbances. However, it is imperative to ensure critical frequency safety limits are not violated while the grid transitions from pre- to post-disturbance operating point. This paper presents a novel safety-enforced consensus method, having three distinct objectives: safe transient frequency evolution, minimizing frequency deviation, and coordinated power sharing. The proposed technique is illustrated using a GFM-interfaced grid-wide storage network on the IEEE 68-bus system under multiple grid transient scenarios.

consensus control↗

Analysis of Actual Operating Conditions of an Off-grid Solid Oxide Fuel Cell

Fuel cells have been proposed as ideal replacements for other technologies in remote locations such as Rural Alaska. A number of suppliers have developed systems that might be applicable in these locations, but there are several requirements that must be met before they can be deployed: they must be able to operate on portable fuels, and be able to operate with little operator assistance for long periods of time. This project was intended to demonstrate the operation of a 5 kW fuel cell on propane at a remote site (defined as one without access to grid power, internet, or cell phone, but on the road system). A fuel cell was purchased by the National Park Service for installation in their newly constructed visitor center at Exit Glacier in the Kenai Fjords National Park. The DOE participation in this project as initially scoped was for independent verification of the operation of this demonstration. This project met with mixed success. The fuel cell has operated over 6 seasons at the facility with varying degrees of success, with one very good run of about 1049 hours late in the summer of 2006, but in general the operation has been below expectations. There have been numerous stack failures, the efficiency of electrical generation has been lower than expected, and the field support effort required has been far higher than expected. Based on the results to date, it appears that this technology has not developed to the point where demonstrations in off road sites are justified.

30 DIRECT ENERGY CONVERSION↗

Techno-Economic and Deployment Analysis of Fossil Fuel-Based Power Generation with Integrated Energy Storage

Most existing coal-fired power plants were designed for sustained operation at full load to maximize efficiency, reliability, and revenues. Depending on plant type and design, these plants can adjust output within a fixed range in response to plant or market conditions. The need for flexibility driven by increased penetration of variable and non-dispatchable power generation such as wind and solar is shifting traditional mission profile of thermoelectric power plants in three ways: more frequent shutdowns when market or grid conditions warrant, more aggressive load ramp rates (rate of output change), and lower minimum sustainable load, which provides a wider operating range and helps avoid costly plant shutdowns. The recent studies have shown that flexibility of a coal-fired power plant can be improved by the energy storage. The objective of this project was to analyze a set of energy storage options (technologies) and determine their impact on flexibility and economics of a representative coal-fired power plant. The effect of five Energy Storage Systems (ESSs) integrated with a coal power plant on plant flexibility and economics was investigated in this study. The results obtained in this project and presented in this report showed that ESS integrated with a thermal power plant improves plant flexibility and participation in the Energy and Ancillary Services markets and also improves plant financial performance.

20 FOSSIL-FUELED POWER PLANTS↗

The development of a charge protocol to take advantage of off- and on-peak demand economics at facilities

This document reports the work performed under Task 1.2.1.1: 'The development of a charge protocol to take advantage of off- and on-peak demand economics at facilities'. The work involved in this task included understanding the experimental results of the other tasks of SOW-5799 in order to take advantage of the economics of electricity pricing differences between on- and off-peak hours and the demonstrated charging and facility energy demand profiles. To undertake this task and to demonstrate the feasibility of plug-in hybrid electric vehicle (PHEV) and electric vehicle (EV) bi-directional electricity exchange potential, BEA has subcontracted Electric Transportation Applications (now known as ECOtality North America and hereafter ECOtality NA) to use the data from the demand and energy study to focus on reducing the electrical power demand of the charging facility. The use of delayed charging as well as vehicle-to-grid (V2G) and vehicle-to-building (V2B) operations were to be considered.

25 ENERGY STORAGE↗

Renewable Generation, Integration of

The integration of renewable generation consists of all of the changes in power system operations that are required in order to allow renewable generation sources to play a significant role in the electricity system. The impacts are mostly due to variable generation (VG), like wind and solar power. Historically these technologies have been labeled as intermittent generation, but recent trendsprefer the label variable generation. Variable generators have a maximum available generation limit that changes with time (variability) and this limit is not known with perfect accuracy (uncertainty). This uncertainty and variability is in addition to that of the existing system and can therefore create additional challenges for grid operators to maintain their current levels of reliability.

24 POWER TRANSMISSION AND DISTRIBUTION↗

High-performance windows improve thermal survivability of occupants during cold snaps

Exposure to low indoor air temperature is a major contributor to temperature-related mortality during extreme cold events, especially when power outages disrupt operation of space heating systems. This study explores the impact of high-performance windows on the thermal resilience of residential buildings during extreme cold weather and grid power outages, as well as their long-term benefits through energy efficiency and reduced risk of property damage. Building performance simulations were conducted for reference residential buildings in three construction vintages and two major U.S. cities located in cold climate zones, considering two types of extreme cold events: short and severe, and long and milder. Our research found that even houses compliant with current energy codes struggle to maintain safe indoor temperatures for more than a few hours during power outages, necessitating rapid evacuations. High-performance windows can extend the thermal survivability time by up to 3.8 days within a 7-day cold snap and significantly reduce risk of bursting frozen water pipes, depending on the building’s insulation and infiltration level, cold event severity, and occupant vulnerability. This extended thermal safety time is crucial in scenarios where reduced mobility complicates emergency responses in senior housing. In addition to boosting thermal resilience, upgrading older homes with high-performance windows can reduce heating energy consumption by over 18% and cooling energy by 15%. Our findings highlight the need to incorporate thermal resilience assessments into new designs or major retrofits, including the use of typical and extreme weather scenarios and advanced technologies like high-performance windows.

Krelling, Amanda F↗

Limiter-aware adaptive excitation control for hydropower generators with legacy voltage regulation systems

Hydropower units often rely on legacy excitation systems with fixed automatic voltage regulator (AVR) settings, but parameter drift, changing operating conditions, and evolving grid-service demands can degrade terminal-voltage regulation over time. This problem should be addressed because poor voltage regulation affects reactive-power support, system stability, and reliable plant operation, and replacing installed AVR and limiter logic is costly and disruptive in practice. To address this issue, this paper proposes a retrofit-friendly enhancement for hydropower generator excitation systems that combines adaptive tuning of the AVR middle lead–lag branch with a small proportional-integral correction for removing steady bias and slow drift. The adaptive laws are normalized, projection-bounded, and equipped with leakage, while adaptation is enabled only in the middle branch. Thus, the intent of the underexcitation and overexcitation limiters, as well as legacy current and rate limits, remains unchanged. Stability is analyzed under incremental performance assumptions, yielding boundedness and asymptotic tracking in the absence of saturation. The method is evaluated using real operational data from a utility-scale hydropower unit at Rocky Reach Dam, Unit C-8. Compared with the fixed AVR baseline, the proposed method reduces terminal-voltage mean squared error by about 70%, removes long periods of steady-state bias, and improves transient tracking while coexisting with limiter actions. These results show that substantial voltage-control improvement can be achieved on existing hydropower units with minimal integration effort and without replacing the installed AVR structure.

ESST5B model↗

Machine Learning-based Cyber-Physical Anomaly Detection in Wide Area Voltage Control Systems

Wide-area voltage control systems (WAVCS) are widely deployed in power grid to improve the voltage stability in transmission system using Flexible AC Transmission System (FACTS) devices. The WAVCS relies on wide-area measurement and control signals for closed-loop control of FACTS devices to improve the transient voltage stability in power grid in real-time. Since the WAVCS utilizes a cyber-layer communication during its normal operation, they are susceptible to cyber attacks from adversaries which can lead to a voltage collapse if the attacks go undetected and unmitigated. This paper proposes a supervised machine learning (ML)-based anomaly detection algorithm for detecting various stealthy cyber attacks in the context of WAVCS cybersecurity. In particular, a fuzzy logic-based wide-area controller, as proposed by the Bonneville Power Administration (BPA), is implemented on the Kundur’s four machine two-area system that is integrated with a static var compensator (SVC) to improve voltage profile on sensitive buses. Later, different types of data integrity attacks, including pulse and ramp attacks, are considered on the wide-area measurement and control signals to analyze the performance of the proposed anomaly detector. Our experimental evaluation shows a promising performance with a high true-positive rate (more than 99%) and low false-negative rate (less than 1%) while exhibiting a small prediction time.

24 POWER TRANSMISSION AND DISTRIBUTION↗