Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Polarization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,351 records · Page 75

Anomalous polarization effects during light scattering in random media

The dependence of the intensity of light backscattered from a layer of a randomly inhomogeneous medium on the polarization of incident light and the size of scatterers has been investigated. The results of numerical simulation have demonstrated that the direction of rotation of the plane of polarization is different in systems with small- and large-scale inhomogeneities. It is shown for the first time that the dependence of the sign of the residual circular polarization on the size of scatterers can be observed in systems described by the Henyey-Greenstein phase function used in simulating biological tissues. A similar anomalous polarization effect, which consists in changing the direction of rotation of the plane of polarization of backscattered light with an increase in the scattering angle, is revealed in studying the coherent backscattering component. These polarization effects are observed in light backscattering from optically active media.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Spectroscopic ellipsometer based on direct measurement of polarization ellipticity

A polarizer-sample-Wollaston prism analyzer ellipsometer is described in which the ellipsometric angles {psi} and {Delta} are determined by direct measurement of the elliptically polarized light reflected from the sample. With the Wollaston prism initially set to transmit p- and s-polarized light, the azimuthal angle P of the polarizer is adjusted until the two beams have equal intensity. This condition yields {psi}={+-}P and ensures that the reflected elliptically polarized light has an azimuthal angle of {+-}45 deg. and maximum ellipticity. Rotating the Wollaston prism through 45 deg. and adjusting the analyzer azimuth until the two beams again have equal intensity yields the ellipticity that allows {Delta} to be determined via a simple linear relationship. The errors produced by nonideal components are analyzed. We show that the polarizer dominates these errors but that for most practical purposes, the error in {psi} is negligible and the error in {Delta} may be corrected exactly. A native oxide layer on a silicon substrate was measured at a single wavelength and multiple angles of incidence and spectroscopically at a single angle of incidence. The best fit film thicknesses obtained were in excellent agreement with those determined using a traditional null ellipsometer.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Resonant Polarization Spectroscopy for Hot X-ray Plasmas

X-ray line polarization spectroscopy is a method of choice for probing hot plasma conditions. The precise roles of resonant structures in this method have not been realized and fully understood. With a sophisticated relativistic close coupling Dirac R-matrix calculation of polarized radiation of the quadrupole magnetic M2 line at 2.717 Å in Ba 46+ , we revealed the nature of resonant structures in x-ray line polarization spectroscopy. We found that signatures with a heavy resonance forest imprinting on polarization may be used for a sensitive new spectroscopic method. The resonant polarization spectrum was used to determine or constrain the directional beam electron distribution of the laboratory Ba plasma. Lastly, our results provide a start of resonant polarization spectroscopy as a method for diagnostics of laboratory, fusion and astrophysical plasma source conditions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Sorption of polar and nonpolar aromatic compounds to two humic acids with varied structural heterogeneity

The major objective of the present study was to evaluate the correlation between structural nature of humic acids (HAs) and sorption affinity of organic compounds with varied polarity. We compared the sorption behavior of three aromatic compounds-nonpolar phenanthrene (PHEN) and 1,2,4,5-tetrachlorobenzene (TeCB) and highly polar 2,4-dichlorophenol (DCP)-to a solid-phase coal humic acid (CHA) and a soil humic acid (SHA) suspended in aqueous solution. The structural nature of HAs was characterized using elemental analysis, ultraviolet absorbance, diffusive reflectance Fourier-transform infrared, and solid-state C-13 nuclear magnetic resonance. The two tested HAs have very different structural properties: CHA consists primarily of poly(methylene)-rich aliphatics with high aromatic content and some COO/N-C=O but low polarity, while SHA consists of young materials of lignin, carbohydrates, and peptides with high polarity. In response to the structural heterogeneity of HAs, sorption of nonpolar and more hydrophobic solutes (PHEN, TeCB) to CHA is much greater than that to SHA because of the predominance of hydrophobic effects; however, disparities in sorption affinity between the two HAs become smaller for polar and less hydrophobic DCP because of the major role played by polar interactions. The influence of pH on the sorption of different solutes to the two HAs was also discussed. The results of the present work highlight the importance of structural heterogeneity of both solutes and HAs in the sorption process.

01 COAL, LIGNITE, AND PEAT↗

MRI of Heterogeneous Hydrogenation Reactions Using Parahydrogen Polarization

The power of magnetic resonance imaging (MRI) is its ability to image the internal structure of optically opaque samples and provide detailed maps of a variety of important parameters, such as density, diffusion, velocity and temperature. However, one of the fundamental limitations of this technique is its inherent low sensitivity. For example, the low signal to noise ratio (SNR) is particularly problematic for imaging gases in porous materials due to the low density of the gas and the large volume occluded by the porous material. This is unfortunate, as many industrially relevant chemical reactions take place at gas-surface interfaces in porous media, such as packed catalyst beds. Because of this severe SNR problem, many techniques have been developed to directly increase the signal strength. These techniques work by manipulating the nuclear spin populations to produce polarized} (i.e., non-equilibrium) states with resulting signal strengths that are orders of magnitude larger than those available at thermal equilibrium. This dissertation is concerned with an extension of a polarization technique based on the properties of parahydrogen. Specifically, I report on the novel use of heterogeneous catalysis to produce parahydrogen induced polarization and applications of this new technique to gas phase MRI and the characterization of micro-reactors. First, I provide an overview of nuclear magnetic resonance (NMR) and how parahydrogen is used to improve the SNR of the NMR signal. I then present experimental results demonstrating that it is possible to use heterogeneous catalysis to produce parahydrogen-induced polarization. These results are extended to imaging void spaces using a parahydrogen polarized gas. In the second half of this dissertation, I demonstrate the use of parahydrogen-polarized gas-phase MRI for characterizing catalytic microreactors. Specifically, I show how the improved SNR allows one to map parameters important for characterizing the heat and mass transport in a heterogeneous catalyst bed. This is followed by appendices containing detailed information regarding the design and use of my experimental setup.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

High-Energy Polarization: Scientific Potential and Model Predictions

Understanding magnetic field strength and morphology is very important for studying astrophysical jets. Polarization signatures have been a standard way to probe the jet magnetic field. Radio and optical polarization monitoring programs have been very successful in studying the space- and time-dependent jet polarization behaviors. A new era is now arriving with high-energy polarimetry. X-ray and γ-ray polarimetry can probe the most active jet regions with the most efficient particle acceleration. This new opportunity will make a strong impact on our current understanding of jet systems. Here, this article summarizes the scientific potential and current model predictions for X-ray and γ-ray polarization of astrophysical jets. In particular, we discuss the advantages of using high-energy polarimetry to constrain several important problems in the jet physics, including the jet radiation mechanisms, particle acceleration mechanisms, and jet kinetic and magnetic energy composition. Here we take blazars as a study case, but the general approach can be similarly applied to other astrophysical jets. We conclude that by comparing combined magnetohydrodynamics (MHD), particle transport, and polarization-dependent radiation transfer simulations with multi-wavelength time-dependent radiation and polarization observations, we will obtain the strongest constraints and the best knowledge of jet physics.

79 ASTRONOMY AND ASTROPHYSICS↗

Radiation and polarization signatures of the 3D multizone time-dependent hadronic blazar model

We present a newly developed time-dependent three-dimensional multizone hadronic blazar emission model. By coupling a Fokker–Planck-based lepto-hadronic particle evolution code, 3DHad, with a polarization-dependent radiation transfer code, 3DPol, we are able to study the time-dependent radiation and polarization signatures of a hadronic blazar model for the first time. Our current code is limited to parameter regimes in which the hadronic γ-ray output is dominated by proton synchrotron emission, neglecting pion production. Our results demonstrate that the time-dependent flux and polarization signatures are generally dominated by the relation between the synchrotron cooling and the light-crossing timescale, which is largely independent of the exact model parameters. We find that unlike the low-energy polarization signatures, which can vary rapidly in time, the high-energy polarization signatures appear stable. Lastly, future high-energy polarimeters may be able to distinguish such signatures from the lower and more rapidly variable polarization signatures expected in leptonic models.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A Lattice Boltzmann Scheme for Polarized Radiative Transfer in Planetary Atmospheres

Quantitative calculation of reflected polarized light from planets is of great significance to interpret the polarimetric observations of planetary atmospheres. In this work, we propose a lattice Boltzmann (LB) scheme for polarized radiative transfer in planetary atmospheres. The LB scheme obtains the Stokes vector through the vector LB equation performing simple collision and streaming processes. The vector radiative transfer equation is rigorously derived from the vector LB equation via the Maxwell iteration technique. Polarized radiative transfer of a single point on the planetary surface with Rayleigh and Mie scattering atmospheres are first accurately solved by our LB scheme. Afterward, we systematically investigate the disk-integrated polarization of finite and semi-infinite, conservative and nonconservative Rayleigh scattering planetary atmospheres. The disk-integrated phase curves of the Stokes parameters and degree of polarization and spherical and geometric albedos are produced, which are in good agreement with the benchmark results for different cases. The numerical results indicate that our LB scheme is efficient and accurate for polarized radiative transfer in planetary atmospheres. Our LB scheme is expected to provide a competitive numerical tool to interpret the polarimetric observations of planetary atmospheres.

47 OTHER INSTRUMENTATION↗

Polarization of Coronal Forbidden Lines

Since the magnetic field is responsible for most manifestations of solar activity, one of the most challenging problems in solar physics is the diagnostics of solar magnetic fields, particularly in the outer atmosphere. To this end, it is important to develop rigorous diagnostic tools to interpret polarimetric observations in suitable spectral lines. This paper is devoted to analyzing the diagnostic content of linear polarization imaging observations in coronal forbidden lines. Although this technique is restricted to off-limb observations, it represents a significant tool to diagnose the magnetic field structure in the solar corona, where the magnetic field is intrinsically weak and still poorly known. We adopt the quantum theory of polarized line formation developed in the framework of the density matrix formalism, and synthesize images of the emergent linear polarization signal in coronal forbidden lines using potential-field source-surface magnetic field models. The influence of electronic collisions, active regions, and Thomson scattering on the linear polarization of coronal forbidden lines is also examined. It is found that active regions and Thomson scattering are capable of conspicuously influencing the orientation of the linear polarization. These effects have to be carefully taken into account to increase the accuracy of the field diagnostics. We also found that linear polarization observation in suitable lines can give valuable information on the long-term evolution of the magnetic field in the solar corona.

79 ASTRONOMY AND ASTROPHYSICS↗

Detection of Polarized Infrared Emission by Polycyclic Aromatic Hydrocarbons in the MWC 1080 Nebula

Polycyclic aromatic hydrocarbons (PAHs) are ubiquitous in astrophysical environments, as revealed by their pronounced emission features at 3.3, 6.2, 7.7, 8.6, 11.3, and 12.7 μ m commonly ascribed to the C–H and C–C vibrational modes. Although these features have long been predicted to be polarized, previous searches for PAH polarization led to null or, at best, tentative detections. Here we report the definite detection of polarized PAH emission at 11.3 μ m in the nebula associated with the Herbig Be star MWC 1080. We measure a polarization degree of 1.9% ± 0.2%, which is unexpectedly high compared to models. This poses a challenge in the current understanding of the alignment of PAHs, which is required to polarize the PAH emission but thought to be substantially suppressed. PAH alignment with a magnetic field via a resonance paramagnetic relaxation process may account for such a high level of polarization.

79 ASTRONOMY AND ASTROPHYSICS↗

154 MHz detection of faint, polarized flares from UV Ceti

We have detected four flares from UV Ceti at 154 MHz using the Murchison Widefield Array. The flares have flux densities between 10 and 65 mJy—a factor of 100 fainter than most flares in the literature at these frequencies—and are only detected in polarization. The circular polarized fractions are limited to >27% at 3σ confidence and two of the flares exhibit polarity reversal. We suggest that these flares occur periodically on a timescale consistent with the rotational period of UV Ceti. During the brightest observed flare, we also detect significant linear polarization with a polarization fraction >18%. Averaging the data in 6 minute, 10 MHz frequency bins we find that the flux density of these flares does not vary over the 30 MHz bandwidth of the Murchison Widefield Array; however, we cannot rule out finer time-frequency structure. Using the measured flux densities for the flares, we estimate brightness temperatures between (10{sup 13}--10{sup 14}) K, indicative of a coherent emission mechanism. The brightness temperature and polarization characteristics point to the electron cyclotron maser mechanism. We also calculate the flare rates given our four observed flares and compare them to flare rates for the set of M dwarf stars with known 100–200 MHz flares. Our measurement is the first for flares with intensities <100 mJy at 100–200 MHz.

79 ASTRONOMY AND ASTROPHYSICS↗

Analysis of JPSS J1 VIIRS Polarization Sensitivity Using the NIST T-SIRCUS

The polarization sensitivity of the Joint Polar Satellite System (JPSS) J1 Visible Infrared Imaging Radiometer Suite (VIIRS) measured pre-launch using a broadband source was observed to be larger than expected for many reflective bands. Ray trace modeling predicted that the observed polarization sensitivity was the result of larger diattenuation at the edges of the focal plane filter spectral bandpass. Additional ground measurements were performed using a monochromatic source (the NIST T-SIRCUS) to input linearly polarized light at a number of wavelengths across the bandpass of two VIIRS spectral bands and two scan angles. This work describes the data processing, analysis, and results derived from the T-SIRCUS measurements, comparing them with broadband measurements. Results have shown that the observed degree of linear polarization, when weighted by the sensor's spectral response function, is generally larger on the edges and smaller in the center of the spectral bandpass, as predicted. However, phase angle changes in the center of the bandpass differ between model and measurement. Integration of the monochromatic polarization sensitivity over wavelength produced results consistent with the broadband source measurements, for all cases considered.

reflective bands↗

Novel calibration system with sparse wires for CMB polarization receivers

B-modes in the cosmic microwave background (CMB) polarization is a smoking gun signature of the inflationary universe. To achieve better sensitivity to this faint signal, CMB polarization experiments aim to maximize the number of detector elements, resulting in a large focal plane receiver. Detector calibration of the polarization response becomes essential. It is extremely useful to be able to calibrate 'simultaneously' all detectors on the large focal plane. We developed a novel calibration system that rotates a large 'sparse' grid of metal wires, in front of and fully covering the field of view of the focal plane receiver. Polarized radiation is created via the reflection of ambient temperature from the wire surface. Since the detector has a finite beam size, the observed signal is smeared according to the beam property. The resulting smeared polarized radiation has a reasonable intensity (a few Kelvin or less) compared to the sky temperature ({approx}10 K observing condition). The system played a successful role for receiver calibration of QUIET, a CMB polarization experiment located in the Atacama desert in Chile. The successful performance revealed that this system is applicable to other experiments based on different technologies, e.g. TES bolometers.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Explore the possibility of accelerating polarized He-3 beam in RHIC

As the world's first high energy polarized proton collider, RHIC has made significant progresses in measuring the proton spin structure in the past decade. In order to have better understanding of the contribution of up quarks and down quarks to the proton spin structure, collisions of high energy polarized neutron beams are required. Polarized He-3 beams offer an effectiveway to provide polarized neutron beams. In this paper, we present studies of accelerating polarized He-3 in RHIC with the current dual snake configuration. Possibilities of adding two more pairs of snakes for accelerating polarized He-3 were explored. Results of six snake configuration in RHIC are also reported in the paper.

43 PARTICLE ACCELERATORS↗

Electron Beam Polarization Measurement Using Touschek Lifetime Technique

Electron beam loss due to intra-beam scattering, the Touschek effect, in a storage ring depends on the electron beam polarization. The polarization of an electron beam can be determined from the difference in the Touschek lifetime compared with an unpolarized beam. In this paper, we report on a systematic experimental procedure recently developed at Duke FEL laboratory to study the radiative polarization of a stored electron beam. Using this technique, we have successfully observed the radiative polarization build-up of an electron beam in the Duke storage ring, and determined the equilibrium degree of polarization and the time constant of the polarization build-up process.

43 PARTICLE ACCELERATORS↗

Executive Summary of the Workshop on Polarization and Beam Energy Measurements at the ILC

This note summarizes the results of the 'Workshop on Polarization and Beam Energy Measurements at the ILC', held at DESY (Zeuthen) April 9-11 2008. The topics for the workshop included (1) physics requirements, (2) polarized sources and low energy polarimetry, (3) BDS polarimeters, (4) BDS energy spectrometers, and (5) physics-based measurements of beam polarization and beam energy from collider data. Discussions focused on the current ILC baseline program as described in the Reference Design Report (RDR), which includes physics runs at beam energies between 100 and 250 GeV, as well as calibration runs on the Z-pole. Electron polarization of P{sub e{sup -}} {approx}> 80% and positron polarization of P{sub e{sup +}} {approx}> 30% are part of the baseline configuration of the machine. Energy and polarization measurements for ILC options beyond the baseline, including Z-pole running and the 1 TeV energy upgrade, were also discussed.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Polarization Analysis of Nonlinear Harmonic Radiation in a Crossed-Planar Undulator

There is growing interest in producing intense, coherent x-ray radiation with an adjustable and arbitrary polarization state. The crossed-planar undulator, which was first proposed by Kim, could achieve rapid polarization control in synchrotron radiation sources and free electron lasers (FELs) through the manipulation of a phase shifter. Recently, a statistical analysis shows that a polarization degree of over 80% is obtainable for a Self-Amplified Spontaneous Emission (SASE) FEL near saturation. In such a scheme, nonlinear harmonic radiation is also generated in each undulator and the polarization of the radiation is controllable in the same manner. In this paper, we study the degree of polarization achievable at the third harmonic in a crossed-planar undulator. We also propose a method for generating second harmonic radiation with arbitrary polarization.

43 PARTICLE ACCELERATORS↗

Local structures of polar wurtzites Zn1-xMgxO studied by raman and 67Zn/25Mg NMR spectroscopies and by total neutron scattering

Research in the area of polar semiconductor heterostructures has been growing rapidly, driven in large part by interest in two-dimensional electron gas (2DEG) systems. 2DEGs are known to form at heterojunction interfaces that bear polarization gradients. They can display extremely high electron mobilities, especially at low temperatures, owing to spatial confinement of carrier motions. Recent reports of 2DEG behaviors in Ga{sub 1-x}Al{sub x}N/GaN and Zn{sub 1-x}Mg{sub x}O/ZnO heterostructures have great significance for the development of quantum Hall devices and novel high-electron-mobility transistors (HEMTs). 2DEG structures are usually designed by interfacing a polar semiconductor with its less or more polar alloys in an epitaxial manner. Since the quality of the 2DEG depends critically on interface perfection, as well as the polarization gradient at the heterojunction, understanding compositional and structural details of the parent and alloy semiconductors is an important component in 2DEG design and fabrication. Zn{sub 1-x}Mg{sub x}O/ZnO is one of the most promising heterostructure types for studies of 2DEGs, due to the large polarization of ZnO, the relatively small lattice mismatch, and the large conduction band offsets in the Zn{sub 1-x}Mg{sub x}O/ZnO heterointerface. Although 2DEG formation in Zn{sub 1-x}Mg{sub x}O/ZnO heterostructures have been researched for some time, a clear understanding of the alloy structure of Zn{sub 1-x}Mg{sub x}O is currently lacking. Here, we conduct a detailed and more precise study of the local structure of Zn{sub 1-x}Mg{sub x}O alloys using Raman and solid-state nuclear magnetic resonance (NMR), in conjunction with neutron diffraction techniques.

36 MATERIALS SCIENCE↗