Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PLANNING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,351 records · Page 75

IMRT Quality Assurance Using a Second Treatment Planning System

We used a second treatment planning system (TPS) for independent verification of the dose calculated by our primary TPS in the context of patient-specific quality assurance (QA) for intensity-modulated radiation therapy (IMRT). QA plans for 24 patients treated with inverse planned dynamic IMRT were generated using the Nomos Corvus TPS. The plans were calculated on a computed tomography scan of our QA phantom that consists of three Solid Water slabs sandwiching radiochromic films, and an ion chamber that is inserted into the center slab of the phantom. For the independent verification, the dose was recalculated using the Varian Eclipse TPS using the multileaf collimator files and beam geometry from the original plan. The data was then compared in terms of absolute dose to the ion chamber volume as well as relative dose on isodoses calculated at the film plane. The calculation results were also compared with measurements performed for each case. When comparing ion chamber doses, the mean ratio was 0.999 (SD 0.010) for Eclipse vs. Corvus, 0.988 (SD 0.020) for the ionization chamber measurements vs. Corvus, and 0.989 (SD 0.017) for the ionization chamber measurements vs. Eclipse. For 2D doses with gamma histogram, the mean value of the percentage of pixels passing the criteria of 3%, 3 mm was 94.4 (SD 5.3) for Eclipse vs. Corvus, 85.1 (SD 10.6) for Corvus vs. film, and 93.7 (SD 4.1) for Eclipse vs. film; and for the criteria of 5%, 3 mm, 98.7 (SD 1.5) for Eclipse vs. Corvus, 93.0 (SD 7.8) for Corvus vs. film, and 98.0 (SD 1.9) for Eclipse vs. film. We feel that the use of the Eclipse TPS as an independent, accurate, robust, and time-efficient method for patient-specific IMRT QA is feasible in clinic.

61 RADIATION PROTECTION AND DOSIMETRY↗

Treating benign optic nerve tumors with a 3-D conformal plan

A 68 year old male patient presented for radiation therapy for treatment of a benign tumor, a glioma of his left optic nerve. The radiation oncologist intended to prescribe 52.2 Gy to the planning target volume, while maintaining a maximum of 54 Gy to the optic nerves and the optic chiasm and a maximum of 40–45 Gy to the globes in order to minimize the possibility of damaging the optic system, which is especially important as this is a benign tumor. The dosimetrist devised a conformal non-coplanar three-dimensional plan with a slightly weighted forward planning component. This plan was created in approximately 15 minutes after the critical organs and the targets were delineated and resulted in an extremely conformal and homogenous plan, treating the target while sparing the nearby critical structures. This approach can also be extended to other tumors in the brain - benign or malignant.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Pencil beam scanning proton therapy vs rotational arc radiation therapy: A treatment planning comparison for postoperative oropharyngeal cancer

Patients diagnosed with head and neck cancer are traditionally treated with photon radiotherapy. Proton therapy is currently being used clinically and may potentially reduce treatment-related toxicities by minimizing the dose to normal organs in the treatment of postoperative oropharyngeal cancer. The finite range of protons has the potential to significantly reduce normal tissue toxicity compared to photon radiotherapy. Seven patients were planned with both proton and photon modalities. The planning goal for both modalities was achieving the prescribed dose to 95% of the planning target volume (PTV). Dose-volume histograms were compared in which all cases met the target coverage goals. Mean doses were significantly lower in the proton plans for the oral cavity (1771 cGy photon vs 293 cGy proton, p < 0.001), contralateral parotid (1796 cGy photon vs 1358 proton, p < 0.001), and the contralateral submandibular gland (3608 cGy photon vs 3251 cGy proton, p = 0.03). Average total integral dose was 9.1% lower in proton plans. The significant dosimetric sparing seen with proton therapy may lead to reduced side effects such as pain, weight loss, taste changes, and dry mouth. Prospective comparisons of protons vs photons for disease control, toxicity, and patient-reported outcomes are therefore warranted and currently being pursued.

61 RADIATION PROTECTION AND DOSIMETRY↗

A comparative study of standard intensity-modulated radiotherapy and RapidArc planning techniques for ipsilateral and bilateral head and neck irradiation

The purpose of this study was to investigate class solutions using RapidArc volumetric-modulated arc therapy (VMAT) planning for ipsilateral and bilateral head and neck (H&N) irradiation, and to compare dosimetric results with intensity-modulated radiotherapy (IMRT) plans. A total of 14 patients who received ipsilateral and 10 patients who received bilateral head and neck irradiation were retrospectively replanned with several volumetric-modulated arc therapy techniques. For ipsilateral neck irradiation, the volumetric-modulated arc therapy techniques included two 360° arcs, two 360° arcs with avoidance sectors around the contralateral parotid, two 260° or 270° arcs, and two 210° arcs. For bilateral neck irradiation, the volumetric-modulated arc therapy techniques included two 360° arcs, two 360° arcs with avoidance sectors around the shoulders, and 3 arcs. All patients had a sliding-window-delivery intensity-modulated radiotherapy plan that was used as the benchmark for dosimetric comparison. For ipsilateral neck irradiation, a volumetric-modulated arc therapy technique using two 360° arcs with avoidance sectors around the contralateral parotid was dosimetrically comparable to intensity-modulated radiotherapy, with improved conformity (conformity index = 1.22 vs 1.36, p < 0.04) and lower contralateral parotid mean dose (5.6 vs 6.8 Gy, p < 0.03). For bilateral neck irradiation, 3-arc volumetric-modulated arc therapy techniques were dosimetrically comparable to intensity-modulated radiotherapy while also avoiding irradiation through the shoulders. All volumetric-modulated arc therapy techniques required fewer monitor units than sliding-window intensity-modulated radiotherapy to deliver treatment, with an average reduction of 35% for ipsilateral plans and 67% for bilateral plans. Thus, for ipsilateral head and neck irradiation a volumetric-modulated arc therapy technique using two 360° arcs with avoidance sectors around the contralateral parotid is recommended. For bilateral neck irradiation, 2- or 3-arc techniques are dosimetrically comparable to intensity-modulated radiotherapy, but more work is needed to determine the optimal approaches by disease site.

61 RADIATION PROTECTION AND DOSIMETRY↗

Monaco treatment planning system tools and optimization processes

The Monaco treatment planning system combines Monte Carlo dose calculation accuracy with robust optimization tools to provide high-quality radiotherapy treatment plans for three-dimensional conformal radiotherapy (3D CRT), intensity modulated radiotherapy (IMRT), volumetric modulated arc therapy (VMAT), stereotactic radiosurgery (SRS), and stereotactic body radiotherapy (SBRT). Recent technology advances have allowed for fast calculation speeds, which allow clinicians and patients to benefit from the accuracy of the Monte Carlo algorithm while reducing overall planning time. A collection of biological and physical dose-based planning tools and templates simplify the planning process and allow for consistent results across organizations. At the same time, multicriteria optimization (MCO) ensures critical organs are spared to the greatest possible degree while maintaining target coverage. Monaco encompasses a full suite of treatment modalities, including conventional radiotherapy and particle therapy, and is paving the way for real-time adaptive treatments with developments in magnetic resonance (MR)-guided radiation therapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Cyberknife stereotactic radiosurgery and radiation therapy treatment planning system

CyberKnife is an image-guided stereotactical dose delivery system designed for both focal irradiation and radiation therapy (SRT). Focal irradiation refers the use of many small beams to deliver highly focus dose to a small target region in a few fractions. The system consists of a 6-MV linac mounted to a robotic arm, coupled with a digital x-ray imaging system. The radiation dose is delivered using many beams oriented at a number of defined or nodal positions around the patients. The CyberKnife can be used for both intracranial and extracranial treaments unlike the Gamma Knife which is limited to intracranial cases. Multiplan (Accuray Inc., Sunnyvale, CA) is the treatment planning system developed to cooperate with this accurate and versatile SRS and SRT system, and exploit the full function of Cyberknife in high-precision radiosurgery and therapy. Optimized inverse treatment plan can be achieved by fine-tuning contours and planning parameters. Precision is the newest version of Cyberknife treatment planning system (TPS) and an upgrade to Multiplan. It offers several new features such as Monte Carlo for multileaf collimator (MLC) and retreatment for other modalities that added more support for the Cyberknife system. The Cybeknife TPS is an easy-to-use and versatile inverse planning platform, suitable for stereotactic radiosurgery and radiation therapy. The knowledge and experience of the planner in this TPS is essential to improve the quality of patient care.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dosimetric evaluation of PLATO and Oncentra treatment planning systems for High Dose Rate (HDR) brachytherapy gynecological treatments

This study compares the dosimetric differences in HDR brachytherapy treatment plans calculated with Nucletron's PLATO and Oncentra MasterPlan treatment planning systems (TPS). Ten patients (1 T1b, 1 T2a, 6 T2b, 2 T4) having cervical carcinoma, median age of 43.5 years (range, 34-79 years) treated with tandem and ring applicator in our institution were selected retrospectively for this study. For both Plato and Oncentra TPS, the same orthogonal films anterior-posterior (AP) and lateral were used to manually draw the prescription and anatomical points using definitions from the Manchester system and recommendations from the ICRU report 38. Data input for PLATO was done using a digitizer and Epson Expression 10000XL scanner was used for Oncentra where the points were selected on the images in the screen. The prescription doses for these patients were 30 Gy to points right A (RA) and left A (LA) delivered in 5 fractions with Ir-192 HDR source. Two arrangements: one dwell position and two dwell positions on the tandem were used for dose calculation. The doses to the patient points right B (RB) and left B (LB), and to the organs at risk (OAR), bladder and rectum for each patient were calculated. The mean dose and the mean percentage difference in dose calculated by the two treatment planning systems were compared. Paired t-tests were used for statistical analysis. No significant differences in mean RB, LB, bladder and rectum doses were found with p-values > 0.14. The mean percent difference of doses in RB, LB, bladder and rectum are found to be less than 2.2%, 1.8%, 1.3% and 2.2%, respectively. Dose calculations based on the two different treatment planning systems were found to be consistent and the treatment plans can be made with either system in our department without any concern.

61 RADIATION PROTECTION AND DOSIMETRY↗

Development and Clustering of Rate-Oriented Load Metrics for Customer Price-Plan Analysis

One of the few methods electric utilities can use to motivate and change customer energy consumption is through retail rate structures. Utilities are increasingly moving toward more dynamic rate plans to encourage energy conservation, utilization of onsite renewable generation, peak demand reduction and flattening of demand profiles. This paper creates a set of rate-oriented load metrics that are the determinants of customers' bills under four unique rate plans. These metrics are not only indicative of which rate structure can provide customer bill reductions based on their load profile characteristics, but also convey useful information about load consumption behavior. With these metrics, utilities can analyze their customers and identify classes that are rewarded under each rate plan. This can help inform utilities whether the customers rewarded under each rate plans are meeting their original objectives. To develop these customer classes, we calculate these rate-oriented load metrics for each customer and perform k-means clustering. The analysis is conducted on a set of 300 customer profiles, examining four different rate plans, different numbers of clusters, customer bills and cluster load profile characteristics.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Stochastic Generation Capacity Expansion Planning with Approximate Dynamic Programming

Failing to consider the many long-term uncertainties that affect the performance of a power generation portfolio can result in suboptimal generation expansion plans. Further, traditional deterministic approaches can omit flexible plans that are able to adapt to future events. In this paper, we explore the use of approximate dynamic programming (ADP) to create forward-looking generation expansion plans. A case study is included with three sequential decision periods; three generation technologies; and four uncertainties: demand growth, natural gas prices, renewable portfolio standards, and the adoption of customer-driven solar generation. The flexible plans found through ADP show a 3 % reduction in total expected cost when compared to myopic planning heuristics while circumventing the computational burdens that accompany high-dimensional dynamic programs.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Performance Evaluation of District Energy Microgrids Planning Tool for Non-Technical Users

Community Microgrids are increasingly gaining popularity worldwide for their efficiency, cost-effectiveness, and local resilience improvement. Microgrid planning tools play a crucial role in their deployment. In the process, tentative designs of the microgrid are simulated, analyzed, and optimized. Due to the complexity of the problem, planning tools must carefully balance computational efficiency while seeking the most optimal solutions. This paper investigates the impact of algorithm selection on CPU and memory utilization of a Community Microgrid planning tool that is specifically designed for non-technical users. We compare two version of the code with two alternatives for Community Microgrid planning tools: a Greedy Algorithm, and a Linear Programming Approach. This comparison examines scenarios spanning from 2 to 50 buildings. Our findings revealed a significant difference in performance between the two algorithms, underscoring the critical role of algorithm selection in optimizing the efficiency of Community Microgrid Planning Tools.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Optimal Nested Test Plan for Combinatorial Quantitative Group Testing

We consider the quantitative group testing problem where the objective is to identify defective items in a given population based on results of tests performed on subsets of the population. Under the quantitative group testing model, the result of each test reveals the number of defective items in the tested group. The minimum number of tests achievable by nested test plans was established by Aigner and Schughart in 1985 within a minimax framework. Furthermore, the optimal nested test plan offering this performance, however, was not obtained. In this paper, we establish the optimal nested test plan in a closed form. This optimal nested test plan is also order optimal among all test plans as the population size approaches infinity. Using heavy-hitter detection as a case study, we show via simulation examples orders of magnitude improvement of the group testing approach over two prevailing sampling-based approaches in detection accuracy and counter consumption. Other applications include anomaly detection and wideband spectrum sensing in cognitive radio systems.

97 MATHEMATICS AND COMPUTING↗

Incorporating uncertainties in respiratory motion into 4D treatment plan optimization

The purpose of this work is to investigate robust 4D optimization techniques which account for respiratory motion uncertainties. Two robust optimization techniques were applied to generate 4D optimized lung treatment plans. The probabilistic optimization approach minimizes the dose variance in the target volume while the worst case optimization minimizes a weighted combination of the nominal and worst case dose distributions which occur in the presence of respiratory motion variation. The two 4D optimization approaches were compared with a margin-based midventilation planning approach in five lung patients. Respiratory motion amplitude and baseline variations were quantified from tidal volume measurements during planning 4D CT acquisition. A similar target coverage was obtained for all three approaches, although the 4D optimization methods tended to be better at sparing the organs at risk. Both robust planning methods are suited for automatic determination of treatment plans which ensure target dose conformality under respiratory motion variations, while minimizing the dose burden of healthy lung tissue.

61 RADIATION PROTECTION AND DOSIMETRY↗

Influence of volumes of prostate, rectum, and bladder on treatment planning CT on interfraction prostate shifts during ultrasound image-guided IMRT

Purpose: The purpose of this study was to analyze the relationship between prostate, bladder, and rectum volumes on treatment planning CT day and prostate shifts in the XYZ directions on treatment days. Methods: Prostate, seminal vesicles, bladder, and rectum were contoured on CT images obtained in supine position. Intensity modulated radiation therapy plans was prepared. Contours were exported to BAT-ultrasound imaging system. Patients were positioned on the couch using skin marks. An ultrasound probe was used to obtain ultrasound images of prostate, bladder, and rectum, which were aligned with CT images. Couch shifts in the XYZ directions as recommended by BAT system were made and recorded. 4698 couch shifts for 42 patients were analyzed to study the correlations between interfraction prostate shifts vs bladder, rectum, and prostate volumes on planning CT. Results: Mean and range of volumes (cc): Bladder: 179 (42-582), rectum: 108 (28-223), and prostate: 55 (21-154). Mean systematic prostate shifts were (cm, {+-}SD) right and left lateral: -0.047{+-}0.16 (-0.361-0.251), anterior and posterior: 0.14{+-}0.3 (-0.466-0.669), and superior and inferior: 0.19{+-}0.26 (-0.342-0.633). Bladder volume was not correlated with lateral, anterior/posterior, and superior/inferior prostate shifts (P>0.2). Rectal volume was correlated with anterior/posterior (P<0.001) but not with lateral and superior/inferior prostate shifts (P>0.2). The smaller the rectal volume or cross sectional area, the larger was the prostate shift anteriorly and vice versa (P<0.001). Prostate volume was correlated with superior/inferior (P<0.05) but not with lateral and anterior/posterior prostate shifts (P>0.2). The smaller the prostate volume, the larger was prostate shift superiorly and vice versa (P<0.05). Conclusions: Prostate and rectal volumes, but not bladder volumes, on treatment planning CT influenced prostate position on treatment fractions. Daily image-guided adoptive radiotherapy would be required for patients with distended or empty rectum on planning CT to reduce rectal toxicity in the case of empty rectum and to minimize geometric miss of prostate.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dosimetric validation of a commercial Monte Carlo based IMRT planning system

Purpose: Recently a commercial Monte Carlo based IMRT planning system (Monaco version 1.0.0) was released. In this study the dosimetric accuracy of this new planning system was validated. Methods: Absolute dose profiles, depth dose curves, and output factors calculated by Monaco were compared with measurements in a water phantom. Different static on-axis and off-axis fields were tested at various source-skin distances for 6, 10, and 18 MV photon beams. Four clinical IMRT plans were evaluated in a water phantom using a linear diode detector array and another six IMRT plans for different tumor sites in solid water using a 2D detector array. In order to evaluate the accuracy of the dose engine near tissue inhomogeneities absolute dose distributions were measured with Gafchromic EBT film in an inhomogeneous slab phantom. For an end-to-end test a four-field IMRT plan was applied to an anthropomorphic lung phantom with a simulated tumor peripherally located in the right lung. Gafchromic EBT film, placed in and around the tumor area, was used to evaluate the dose distribution. Results: Generally, the measured and the calculated dose distributions agreed within 2% dose difference or 2 mm distance-to-agreement. But mainly at interfaces with bone, some larger dose differences could be observed. Conclusions: Based on the results of this study, the authors concluded that the dosimetric accuracy of Monaco is adequate for clinical introduction.

61 RADIATION PROTECTION AND DOSIMETRY↗

Fundus image fusion in EYEPLAN software: An evaluation of a novel technique for ocular melanoma radiation treatment planning

Purpose: The purpose of this study is to evaluate a novel approach for treatment planning using digital fundus image fusion in EYEPLAN for proton beam radiation therapy (PBRT) planning for ocular melanoma. The authors used a prototype version of EYEPLAN software, which allows for digital registration of high-resolution fundus photographs. The authors examined the improvement in tumor localization by replanning with the addition of fundus photo superimposition in patients with macular area tumors. Methods: The new version of EYEPLAN (v3.05) software allows for the registration of fundus photographs as a background image. This is then used in conjunction with clinical examination, tantalum marker clips, surgeon's mapping, and ultrasound to draw the tumor contour accurately. In order to determine if the fundus image superimposition helps in tumor delineation and treatment planning, the authors identified 79 patients with choroidal melanoma in the macular location that were treated with PBRT. All patients were treated to a dose of 56 GyE in four fractions. The authors reviewed and replanned all 79 macular melanoma cases with superimposition of pretreatment and post-treatment fundus imaging in the new EYEPLAN software. For patients with no local failure, the authors analyzed whether fundus photograph fusion accurately depicted and confirmed tumor volumes as outlined in the original treatment plan. For patients with local failure, the authors determined whether the addition of the fundus photograph might have benefited in terms of more accurate tumor volume delineation. Results: The mean follow-up of patients was 33.6{+-}23 months. Tumor growth was seen in six eyes of the 79 macular lesions. All six patients were marginal failures or tumor miss in the region of dose fall-off, including one patient with both in-field recurrence as well as marginal. Among the six recurrences, three were managed by enucleation and one underwent retreatment with proton therapy. Three patients developed distant metastasis and all three patients have since died. The replanning of six patients with their original fundus photograph superimposed showed that in four cases, the treatment field adequately covered the tumor volume. In the other two patients, the overlaid fundus photographs indicated the area of marginal miss. The replanning with the fundus photograph showed improved tumor coverage in these two macular lesions. For the remaining patients without local failure, replanning with fundus photograph superimposition confirmed the tumor volume as drawn in the original treatment plan. Conclusions: Local control was excellent in patients receiving 56 GyE of PBRT for uveal melanomas in the macular region, which traditionally can be more difficult to control. Posterior lesions are better defined with the additional use of fundus image since they can be difficult to mark surgically. In one-third of treatment failing patients, the superposition of the fundus photograph would have clearly allowed improved localization of tumor. The current practice standard is to use the superimposition of the fundus photograph in addition to the surgeon's clinical and clip mapping of the tumor and ultrasound measurement to draw the tumor volume.

60 APPLIED LIFE SCIENCES↗

Advanced treatment planning methods for efficient radiation therapy with laser accelerated proton and ion beams

Purpose: Laser plasma acceleration can potentially replace large and expensive cyclotrons or synchrotrons for radiotherapy with protons and ions. On the way toward a clinical implementation, various challenges such as the maximum obtainable energy still remain to be solved. In any case, laser accelerated particles exhibit differences compared to particles from conventional accelerators. They typically have a wide energy spread and the beam is extremely pulsed (i.e., quantized) due to the pulsed nature of the employed lasers. The energy spread leads to depth dose curves that do not show a pristine Bragg peak but a wide high dose area, making precise radiotherapy impossible without an additional energy selection system. Problems with the beam quantization include the limited repetition rate and the number of accelerated particles per laser shot. This number might be too low, which requires a high repetition rate, or it might be too high, which requires an additional fluence selection system to reduce the number of particles. Trying to use laser accelerated particles in a conventional way such as spot scanning leads to long treatment times and a high amount of secondary radiation produced when blocking unwanted particles. Methods: The authors present methods of beam delivery and treatment planning that are specifically adapted to laser accelerated particles. In general, it is not necessary to fully utilize the energy selection system to create monoenergetic beams for the whole treatment plan. Instead, within wide parts of the target volume, beams with broader energy spectra can be used to simultaneously cover multiple axially adjacent spots of a conventional dose delivery grid as applied in intensity modulated particle therapy. If one laser shot produces too many particles, they can be distributed over a wider area with the help of a scattering foil and a multileaf collimator to cover multiple lateral spot positions at the same time. These methods are called axial and lateral clustering and reduce the number of particles that have to be blocked in the beam delivery system. Furthermore, the optimization routine can be adjusted to reduce the number of dose spots and laser shots. The authors implemented these methods into a research treatment planning system for laser accelerated particles. Results: The authors' proposed methods can decrease the amount of secondary radiation produced when blocking particles with wrong energies or when reducing the total number of particles from one laser shot. Additionally, caused by the efficient use of the beam, the treatment time is reduced considerably. Both improvements can be achieved without extensively changing the quality of the treatment plan since conventional intensity modulated particle therapy usually includes a certain amount of unused degrees of freedom which can be used to adapt to laser specific properties. Conclusions: The advanced beam delivery and treatment planning methods reduce the need to have a perfect laser-based accelerator reproducing the properties of conventional accelerators that might not be possible without increasing treatment time and secondary radiation to the patient. The authors show how some of the differences to conventional beams can be overcome and efficiently used for radiation treatment.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Inverse planning for IMRT with nonuniform beam profiles using total-variation regularization (TVR)

Purpose: Radiation therapy with high dose rate and flattening filter-free (FFF) beams has the potential advantage of greatly reduced treatment time and out-of-field dose. Current inverse planning algorithms are, however, not customized for beams with nonuniform incident profiles and the resultant IMRT plans are often inefficient in delivery. The authors propose a total-variation regularization (TVR)-based formalism by taking the inherent shapes of incident beam profiles into account. Methods: A novel TVR-based inverse planning formalism is established for IMRT with nonuniform beam profiles. The authors introduce a TVR term into the objective function, which encourages piecewise constant fluence in the nonuniform FFF fluence domain. The proposed algorithm is applied to lung and prostate and head and neck cases and its performance is evaluated by comparing the resulting plans to those obtained using a conventional beamlet-based optimization (BBO). Results: For the prostate case, the authors' algorithm produces acceptable dose distributions with only 21 segments, while the conventional BBO requires 114 segments. For the lung case and the head and neck case, the proposed method generates similar coverage of target volume and sparing of the organs-at-risk as compared to BBO, but with a markedly reduced segment number. Conclusions: TVR-based optimization in nonflat beam domain provides an effective way to maximally leverage the technical capacity of radiation therapy with FFF fields. The technique can generate effective IMRT plans with improved dose delivery efficiency without significant deterioration of the dose distribution.

60 APPLIED LIFE SCIENCES↗

Deformable planning CT to cone-beam CT image registration in head-and-neck cancer

Purpose: The purpose of this work was to implement and validate a deformable CT to cone-beam computed tomography (CBCT) image registration method in head-and-neck cancer to eventually facilitate automatic target delineation on CBCT. Methods: Twelve head-and-neck cancer patients underwent a planning CT and weekly CBCT during the 5-7 week treatment period. The 12 planning CT images (moving images) of these patients were registered to their weekly CBCT images (fixed images) via the symmetric force Demons algorithm and using a multiresolution scheme. Histogram matching was used to compensate for the intensity difference between the two types of images. Using nine known anatomic points as registration targets, the accuracy of the registration was evaluated using the target registration error (TRE). In addition, region-of-interest (ROI) contours drawn on the planning CT were morphed to the CBCT images and the volume overlap index (VOI) between registered contours and manually delineated contours was evaluated. Results: The mean TRE value of the nine target points was less than 3.0 mm, the slice thickness of the planning CT. Of the 369 target points evaluated for registration accuracy, the average TRE value was 2.6{+-}0.6 mm. The mean TRE for bony tissue targets was 2.4{+-}0.2 mm, while the mean TRE for soft tissue targets was 2.8{+-}0.2 mm. The average VOI between the registered and manually delineated ROI contours was 76.2{+-}4.6%, which is consistent with that reported in previous studies. Conclusions: The authors have implemented and validated a deformable image registration method to register planning CT images to weekly CBCT images in head-and-neck cancer cases. The accuracy of the TRE values suggests that they can be used as a promising tool for automatic target delineation on CBCT.

60 APPLIED LIFE SCIENCES↗