Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PHASE DETECTOR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,351 records · Page 75

Measurements of the CKM angle gamma at BaBar

We report on our recent measurements of the Cabibbo-Kobayashi-Maskawa CP-violating phase {gamma} and of related CP-asymmetries and branching fraction ratios. The measurements have been performed on samples of up to 465 million B{bar B} pairs collected by the BABAR detector at the SLAC PEP-II asymmetric-energy B factory in the years 1999-2007.

43 PARTICLE ACCELERATORS↗

2011 Laser Diagnostics in Combustion Gordon Research Conference, (August 14-19, 2011, Waterville Valley Resort, Waterville Valley, NH)

The vast majority of the world's energy needs are met by combustion of fossil fuels. Optimum utilization of limited resources and control of emissions of pollutants and greenhouse gases demand sustained improvement of combustion technology. This task can be satisfied only by detailed knowledge of the underlying physical and chemical processes. Non-intrusive laser diagnostics continuously contribute to our growing understanding of these complex and coupled multi-scale processes. The GRC on Laser Diagnostics in Combustion focuses on the most recent scientific advances and brings together scientists and engineers working at the leading edge of combustion research. Major tasks of the community are developing and applying methods for precise and accurate measurements of fluid motion and temperatures; chemical compositions; multi-phase phenomena appearing near walls, in spray and sooting combustion; improving sensitivities, precision, spatial resolution and tracking transients in their spatio-temporal development. The properties and behaviour of novel laser sources, detectors, optical systems that lead to new diagnostic capabilities are also part of the conference program.

42 ENGINEERING↗

Wavefront detector

A wavefront sensor system suitable for integration into an integrated circuit light detector may provide for wave angle sensors having varying functional relationships between the wave angle and signal to provide improved dynamic range. These wave angle sensors may be combined with integrated circuit phase angle sensors for a more complete analysis of the waveform.

42 ENGINEERING↗

Wavefront detector

A wavefront sensor system suitable for integration into an integrated circuit light detector may provide for wave angle sensors having varying functional relationships between the wave angle and signal to provide improved dynamic range. These wave angle sensors may be combined with integrated circuit phase angle sensors for a more complete analysis of the waveform.

Yu, Zongfu↗

ALTERNATIVES TO HELIUM-3 FOR NEUTRON MULTIPLICITY DETECTORS

Collaboration between the Pacific Northwest National Laboratory (PNNL) and the Los Alamos National Laboratory (LANL) is underway to evaluate neutron detection technologies that might replace the high-pressure helium (3He) tubes currently used in neutron multiplicity counter for safeguards applications. The current stockpile of 3He is diminishing and alternatives are needed for a variety of neutron detection applications including multiplicity counters. The first phase of this investigation uses a series of Monte Carlo calculations to simulate the performance of an existing neutron multiplicity counter configuration by replacing the 3He tubes in a model for that counter with candidate alternative technologies. These alternative technologies are initially placed in approximately the same configuration as the 3He tubes to establish a reference level of performance against the 3He-based system. After these reference-level results are established, the configurations of the alternative models will be further modified for performance optimization. The 3He model for these simulations is the one used by LANL to develop and benchmark the Epithermal Neutron Multiplicity Counter (ENMC) detector, as documented by H.O. Menlove, et al. in the 2004 LANL report LA-14088. The alternative technologies being evaluated are the boron-tri-fluoride-filled proportional tubes, boron-lined tubes, and lithium coated materials previously tested as possible replacements in portal monitor screening applications, as documented by R.T. Kouzes, et al. in the 2010 PNNL report PNNL-72544 and NIM A 623 (2010) 1035–1045. The models and methods used for these comparative calculations will be described and preliminary results shown

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Measurement of the CP violating phase β s in B 0 s J/ΨΦ decays

The CP violating phase β j/ΨΦ s is measured in decays of B 0 s → J/ΨΦ. This measurement uses 5.2 fb -1 of data collected in √s = 1.96 TeV p$\bar{p}$ collisions at the Fermilab Tevatron with the CDF Run-II detector. CP violation in the B s 0 -$\bar{B}$ s 0 system is predicted to be very small in the Standard Model. However, several theories beyond the Standard Model allow enhancements to this quantity by heavier, New Physics particles entering second order weak mixing box diagrams. Previous measurements have hinted at a deviation from the Standard Model expectation value for β s J/ΨΦ with a significance of approximately 2σ. The measurement described in this thesis uses the highest statistics sample available to date in the B s 0 → J/ΨΦ decay channel, where J/Ψ → μ + μ - and Φ → K + K - . Furthermore, it contains several improvements over previous analyses, such as enhanced signal selection, fully calibrated particle ID and flavour tagging, and the inclusion of an additional decay component in the likelihood function. The added decay component considers S-wave states of KK pairs in the B s 0 → J/Ψ K + K - channel. The results are presented as 2-dimensional frequentist confidence regions for β s J/ΨΦ and ΔΓ (the width difference between the B s 0 mass eigenstates), and as a confidence interval for β s J/ΨΦ of [0.02,0.52] U [1.08, 1.55] at the 68% confidence level. The measurement of the CP violating phase obtained in this thesis is complemented by the world's most precise measurement of the lifetime τ s = 1.53 ± 0.025 (stat.) ± 0.012 (syst.) ps and decay width difference ΔΓ = 0.075 ± 0.035 (stat.) ± 0.01 (syst.) ps -1 of the B s 0 meson, with the assumption of no CP violation.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

First Measurement of Differential Charged Current Quasielastic-like $\nu_\mu$–Argon Scattering Cross Sections In Kinematic Imbalance Variables With The MicroBooNE Detector

We report the first measurement of flux-integrated multi-differential cross sections for charged-current events with muon neutrinos scattering on argon with solely a muon and a single proton in the final state as a function of kinematic imbalance variables. The measurement was carried out using the Booster Neutrino Beam at Fermi National Accelerator Laboratory within the MicroBooNE Liquid Argon Time Projection Chamber detector with an exposure of 6.79 × 10 20 protons on target. Events were selected to enhance the contribution of charged-current mesonless interactions with one proton detected in the final state. The data discussed here are reported in terms of multidifferential cross sections in kinematic imbalance variables, which are generally sensitive to nuclear effects. The double-differential results in these variables can provide an excellent handle to disentagle specific nuclear aspects not easily isolated via single differential cross sections. Our results pave a path towards identifying regions of the phase-space where future interaction modeling development and Monte Carlo neutrino generator tuning efforts should concentrate. EVENT SELECTION Neutrino oscillation measurements aim to extract neutrino mixing angles, mass differences, the value of the chargeparity violating phase in the lepton sector, and to search for new physics beyond the Standard Model [1, 2]. For that to be achieved, an unprecedented understanding of neutrino-argon interactions is of utmost importance since a growing number of neutrino oscillation experiments employ Liquid Argon Time Projector Chamber (LArTPC) neutrino detectors [3–6]. The accuracy to which these experiments can extract neutrino oscillation parameters requires a good understanding of the neutrino energy. Experimentally, this energy is deduced from the measured kinetic energies of particles that are emitted following the neutrino interaction in the detector. The kinematic properties of such finalstate particles reflect complex dynamics due to nuclear and initial-state effects of the interaction [7]. However, certain categories of nuclear effects can be isolated by variables built specifically to characterize the degeneracy between such effects [8–10]. This note reports cross sections in kinematic variables sensitive to nuclear effects using events with one detected muon with momentum 0.1 < pµ < 1.2 GeV/c, and exactly one proton with 0.3 < pp < 1 GeV/c. This signal definition includes events with any number of protons below 300 MeV/c, neutrons at any momenta, and charged pions with momentum lower than 70 MeV/c. This choice is guided by the fact that their experimental signature of correlated muon-proton pairs is fairly straightforward to reconstruct [11–22]. Such events primarily originate from chargedcurrent (CC) neutrino-nucleon quasielastic (QE) scattering interactions where the neutrino removes a single intact nucleon from the nucleus without producing any additional particles. This definition can also include contributions from interactions that lead to the production of additional particles that are absent from the final state due to nuclear effects, such as pion absorption, or have momenta that are below the experimental detection threshold.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Transport of polar molecules by an alternating-gradient guide

An alternating-gradient electric guide provides a way to transport a wide variety of polar molecules, including those in high-field-seeking states. We investigate the motion of polar molecules in such a guide by measuring the transmission of CaF molecules in their high-field-seeking ground state, with the guide operating at a variety of switching frequencies and voltages. We model the guide using analytical and numerical techniques and compare the predictions of these models to the experimental results and to one another. The analytical results are approximate but provide simple and useful estimates for the maximum phase-space acceptance of the guide and for the switching frequency required. The numerical methods provide more accurate results over the full range of switching frequencies. Our investigation shows that, even when the fields are static, some high-field-seeking molecules are able to pass through the guide on metastable trajectories. We show that the maximum possible transmission requires accurate alignment within the guide and between the guide and detector.

74 ATOMIC AND MOLECULAR PHYSICS↗

A data acquisition system for longitudinal beam properties in a rapid cycling synchrotron

A longitudinal beam properties, data acquisition system has been commissioned to operate in the Fermilab booster ring. This system captures real time information including beam synchronous phase, bunch length, and coupled bunch instability amplitudes as the beam is accelerated from 400 MeV to 8 GeV in 33 ms. The system uses an off-the-shelf Tektronix oscilloscope running Labview software and a synchronous pulse generator. This paper describes the hardware configuration and the software configuration used to optimize the data processing rate. The Fermilab Booster is currently pushed to its intensity limit due to the high demand from different experiments for protons. This will continue into the era of the intensity frontier. While intensity is the most critical parameter, emittance must be controlled as well. Longitudinal emittance is an important parameter for optimizing the slip stacking process in the Main Injector. Longitudinal instabilities can spoil the emittance, so it is important to monitor bunch lengths and bunch phase oscillations in the Booster. The Booster presents a special challenge when it comes to measuring beam properties. The acceleration ramp is short (33ms), and the RF frequency varies from 38-52.8 MHz. Standard instrumentation like spectrum analyzers and network analyzers cannot effectively measure beam properties, because they cannot track the changing frequencies. Early instrumentation involved a series of tracking oscillators, mixers, and diode detectors that would require vigilant calibration. There was a demand for a more robust means of gathering beam parameters.

43 PARTICLE ACCELERATORS↗

A concept for a magnetic field detector underpinned by the nonlinear dynamics of coupled multiferroic devices

Multiferroic (MF) composites, in which magnetic and ferroelectric orders coexist, represent a very attractive class of materials with promising applications in areas, such as spintronics, memories, and sensors. One of the most important multiferroics is the perovskite phase of bismuth ferrite, which exhibits weak magnetoelectric properties at room temperature; its properties can be enhanced by doping with other elements such as dysprosium. A recent paper has demonstrated that a thin film of Bi{sub 0.7}Dy{sub 0.3}FeO{sub 3} shows good magnetoelectric coupling. In separate work it has been shown that a carefully crafted ring connection of N (N odd and N ≥ 3) ferroelectric capacitors yields, past a critical point, nonlinear oscillations that can be exploited for electric (E) field sensing. These two results represent the starting point of our work. In this paper the (electrical) hysteresis, experimentally measured in the MF material Bi{sub 0.7}Dy{sub 0.3}FeO{sub 3}, is characterized with the applied magnetic field (B) taken as a control parameter. This yields a “blueprint” for a magnetic (B) field sensor: a ring-oscillator coupling of N = 3 Sawyer-Tower circuits each underpinned by a mutliferroic element. In this configuration, the changes induced in the ferroelectric behavior by the external or “target” B-field are quantified, thus providing a pathway for very low power and high sensitivity B-field sensing.

36 MATERIALS SCIENCE↗

A method for direct, semi-quantitative analysis of gas phase samples using gas chromatography-inductively coupled plasma-mass spectrometry

A new and complete GC–ICP-MS method is described for direct analysis of trace metals in a gas phase process stream. The proposed method is derived from standard analytical procedures developed for ICP-MS, which are regularly exercised in standard ICP-MS laboratories. In order to implement the method, a series of empirical factors were generated to calibrate detector response with respect to a known concentration of an internal standard analyte. Calibrated responses are ultimately used to determine the concentration of metal analytes in a gas stream using a semi-quantitative algorithm. The method was verified using a traditional gas injection from a GC sampling valve and a standard gas mixture containing either a 1 ppm Xe + Kr mix with helium balance or 100 ppm Xe with helium balance. Data collected for Xe and Kr gas analytes revealed that agreement of 6–20% with the actual concentration can be expected for various experimental conditions. To demonstrate the method using a relevant “unknown” gas mixture, experiments were performed for continuous 4 and 7 hour periods using a Hg-containing sample gas that was co-introduced into the GC sample loop with the xenon gas standard. System performance and detector response to the dilute concentration of the internal standard were pre-determined, which allowed semi-quantitative evaluation of the analyte. The calculated analyte concentrations varied during the course of the 4 hour experiment, particularly during the first hour of the analysis where the actual Hg concentration was under predicted by up to 72%. Calculated concentration improved to within 30–60% for data collected after the first hour of the experiment. Similar results were seen during the 7 hour test with the deviation from the actual concentration being 11–81% during the first hour and then decreasing for the remaining period. The method detection limit (MDL) was determined for the mercury by injecting the sample gas into the system following a period of equilibration. The MDL for Hg was calculated as 6.8 μg · m -3 . This work describes the first complete GC–ICP-MS method to directly analyze gas phase samples, and detailed sample calculations and comparisons to conventional ICP-MS methods are provided.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Amplitude analysis and branching-fraction measurement of ${D}_s^{+}\to {K}_S^0{\pi}^{+}{\pi}^0$

By using 6.32 fb -1 of data collected with the BESIII detector at center-of-mass energies between 4.178 and 4.226 GeV, we perform an amplitude analysis of the decay $D^+_s$→$K^0_Sπ^+π^0$ and determine the relative fractions and phase differences of different intermediate processes, which include $K^0_Sρ$(770) + ,$K^0_Sρ$(1450) + , $K^*$(892)$^0π^+$, $K^*$(892)$^+π^0$, and $K^*$(1410)$^0π^+$. With the detection efficiency based on the amplitude analysis results, the absolute branching fraction is measured to be $\mathcal{B}$($D^+_s$→$K^0_Sπ^+π^0$)=(5.43±0.30 stat ±0.15 syst )×10 -3 .

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Structural and pyroelectric properties of sol-gel derived multiferroic BFO thin films

Highlights: Black-Right-Pointing-Pointer We fabricated multiferroic BFO/PZT multilayer films by spin-coating method. Black-Right-Pointing-Pointer The trap centers of carriers were formed at the interfaces between BFO and PZT films. Black-Right-Pointing-Pointer The ferroelectric properties were superior to those of single composition BFO film. -- Abstract: Multiferroic BFO/PZT multilayer films were fabricated by spin-coating method on the (1 1 1)Pt/Ti/SiO{sub 2}/Si substrate alternately using PZT(30/70), PZT(70/30) and BFO alkoxide solutions. The structural and ferroelectric properties were investigated for uncooled infrared detector applications. The coating and heating procedure was repeated six times to form BFO/PZT multilayer films. All films showed the typical XRD patterns of the perovskite polycrystalline structure without presence of the second phase such as Bi{sub 2}Fe{sub 4}O{sub 3}. The thickness of BFO/PZT multilayer film was about 200-220 nm. The ferroelectric properties such as dielectric constant, remnant polarization and pyroelectric coefficient were superior to those of single composition BFO film, and those values for BFO/PZT(70/30) multilayer film were 288, 15.7 {mu}C/cm{sup 2} and 9.1 Multiplication-Sign 10{sup -9} C/cm{sup 2} K at room temperature, respectively. Leakage current density of the BFO/PZT(30/70) multilayer film was 3.3 Multiplication-Sign 10{sup -9} A/cm{sup 2} at 150 kV/cm. The figures of merit, F{sub V} for the voltage responsivity and F{sub D} for the specific detectivity, of the BFO/PZT(70/30) multilayer film were 6.17 Multiplication-Sign 10{sup -11} Ccm/J and 6.45 Multiplication-Sign 10{sup -9} Ccm/J, respectively.

36 MATERIALS SCIENCE↗

Periodicities in the X-ray emission from the solar corona

We have studied the time series of full disk integrated soft and hard X-ray emission from the solar corona during 2004 January to 2008 December, covering the entire descending phase of solar cycle 23 from a global point of view. We employ the daily X-ray index derived from 1 s cadence X-ray observations from the Si and CZT detectors of the 'Solar X-ray Spectrometer' mission in seven different energy bands ranging between 6 and 56 keV. X-ray data in the energy bands 6-7, 7-10, 10-20, and 4-25 keV from the Si detector are considered, while 10-20, 20-30, and 30-56 keV high energy observations are taken from the CZT detector. The daily time series is subjected to power spectrum analysis after appropriate correction for noise. The Lomb-Scargle periodogram technique has shown prominent periods of ∼13.5 days, ∼27 days, and a near-Rieger period of ∼181 days and ∼1.24 yr in all energy bands. In addition to this, other periods like ∼31, ∼48, ∼57, ∼76, ∼96, ∼130, ∼227, and ∼303 days are also detected in different energy bands. We discuss our results in light of previous observations and existing numerical models.

79 ASTRONOMY AND ASTROPHYSICS↗

LEIC - A Polarized Low Energy Electron-ion Collider at Jefferson Lab

A polarized electron-ion collider is envisioned as the future nuclear science program at JLab beyond the 12 GeV CEBAF. Presently, a medium energy collider (MEIC) is set as an immediate goal with options for a future energy upgrade. A comprehensive design report for MEIC has been released recently. The MEIC facility could also accommodate electron and proton/ion collisions in a low CM energy range, covering proton energies from 10 to 25 GeV and ion energies with a similar magnetic rigidity, for additional science reach. In this paper, we present a conceptual design of this low energy collider, LEIC, showing its luminosity can reach above 10{sup 33} cm{sup -2}s{sup -1}. The design specifies that the large booster of the MEIC is converted to a low energy ion collider ring with an interaction region and an electron cooler integrated into it. The design provides options for either sharing the detector with the MEIC or a dedicated low energy detector in a third collision point, with advantages of either a minimum cost or extra detection parallel to the MEIC operation, respectively. The LEIC could be positioned as the first and low cost phase of a multi-stage approach to realize the full MEIC.

43 PARTICLE ACCELERATORS↗

Ultrafast transient grating radiation to optical image converter

A high sensitivity transient grating ultrafast radiation to optical image converter is based on a fixed transmission grating adjacent to a semiconductor substrate. X-rays or optical radiation passing through the fixed transmission grating is thereby modulated and produces a small periodic variation of refractive index or transient grating in the semiconductor through carrier induced refractive index shifts. An optical or infrared probe beam tuned just below the semiconductor band gap is reflected off a high reflectivity mirror on the semiconductor so that it double passes therethrough and interacts with the radiation induced phase grating therein. A small portion of the optical beam is diffracted out of the probe beam by the radiation induced transient grating to become the converted signal that is imaged onto a detector.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Potential sterile neutrino search utilizing spectral distortion in a two-reactor/one-detector configuration

There is an observed deficit of about 6% in the expected rate of anti-neutrino interactions when averaging over many different reactor experiments. While the significance of the deficit is low (98.6 % CL), there is speculation that a non-interacting “sterile” neutrino could be the cause. Here, we explore the possibility of a two-reactor/one-detector experiment at intermediate distances (100-500 meters) to look for a sterile neutrino in the mass range implied by this deficit. A method for probing Δm 2 phase space is developed using interference patterns between two oscillated spectra at different baselines. This method is used to investigate the potential sensitivity of the Double Chooz experiment, which has a single Near Detector at distances of 351 m and 465 m from two reactors of identical design. We conclude that Double Chooz could investigate sterile neutrino in the Δm 2 range of 0.002 to 0.5 eV 2 over 5 years of near detector running.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗