Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Nuclear Engineering”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,351 records · Page 75

TREAT Slide Decks for Alabama A&M

Slides to introduce TREAT and two senior design projects to a professor and senior engineering students at Alabama A&M. Slide Deck 1 is an overview of the TREAT Reactor and its mission. Use for Space Nuclear Thermal Propulsion Testing is mentioned, but no details of space reactor fuel are included. Review for unlimited release is requested. Slide deck 2 presents technical background for neutron radiography, with contrast to x-radiography, and then presents the application of TREAT for Flash Radiography. Slide Deck 3 describes the background behind the second senior design project, which is to design powered actuators for TREAT core clamps. Slide Deck 3 includes photos of different sides of the TREAT reactor and sketches of internal components associated with the core clamping system. These were presented via Teams on October 5, but we want to provide the slidedeck files to the university for student reference.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Addendum to Capability Needs for Irradiated and Radioactive Materials Research (Ad Hoc Committee Summary Report)

Nuclear materials and fuels studies are challenging research and engineering targets because of their inherent radioactivity as well as their heterogeneous microstructure. Advanced light sources have made significant underpinning scientific contributions to the understanding of structural and fuel cladding material microstructure and properties and the development of structure-property relationships. These facilities have the potential to help advance the Department of Energy (DOE) Office of Nuclear Energy (DOE-NE) mission priorities providing underpinning understanding of technically important challenges, including: irradiation induced embrittlement and swelling; stress corrosion cracking and corrosion in extreme environments; ageing of reactor pressure vessels steels; nuclear fuel characterization; and nuclear waste form optimization as well as playing a major role in the development of a materials performance matrix to aid in the design of new materials to meet the needs of advanced reactor concepts. However, the delivery of underpinning understanding is the mission of DOE Office of Science (DOE-SC). While filling such knowledge gaps is important, efforts in this direction should not be confused with the strategic technology focused mission goals of DOE-NE to enable the continued operation of existing U.S. nuclear reactors, to enable the deployment of advanced nuclear reactors, to develop advanced nuclear fuel cycles, and to maintain U.S. leadership in nuclear energy technology.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Feasibility of a multigroup Boltzmann–Fokker–Planck solution for electron beam dose calculations

Legacy nuclear-reactor Boltzmann solvers start clinical deployment as an alternative to Monte Carlo (MC) codes and Fermi–Eyges semiemprical models in radiation oncology treatment planning. Today’s certified clinical solvers are limited to photon beams. In this paper, ELECTR, a state-of-the-art multigroup electron cross sections generation module in NJOY is presented and validated against Lockwood’s calorimetric measurements, EGS-nrc and GEANT-4 for 1–20 MeV unidirectional electron beams. The nuclear-reactor DRAGON-5 solver is upgraded to access the library and solve the Boltzmann–Fokker–Planck (BFP) equation. A variety of heterogeneous radiotherapy and radiosurgery phantom configurations were used for validation purpose. Case studies include a thorax benchmark, that of a typical breast Intra-Operative Radiotherapy and a high-heterogeneity patient-like benchmark. For all beams, 100% of the water voxels satisfied the American Association of Physicists in Medicine accuracy criterion for a BFP-MC dose error below 2%. At least, 97.0% of adipose, muscle, bone, lung, tumor and breast voxels satisfied the 2% criterion. The average BFP-MC relative error was about 0.56% for all voxels, beams and materials combined. By irradiating homogeneous slabs from Z = 1 (hydrogen) to Z = 99 (einsteinium), we reported performance and defects of the CEPXS mode [US. Sandia National Lab., SAND-89-1685] in ELECTR for the entire periodic table. For all Lockwood’s benchmarks, NJOY-DRAGON dose predictions are within the experimental data precision for 98% of voxels.

42 ENGINEERING↗

Soil Sampling Results for Closure of a Portion of Solid Waste Management Unit #16

The U.S. Department of Energy/National Nuclear Security Administration (DOE/ NNSA) and National Technology & Engineering Solutions of Sandia, LLC (NTESS), the management and operating contractor for Sandia National Laboratories/California (SNL/CA), has prepared this soil sampling results report for closure of a portion of Solid Waste Management Unit (SWMU) #16. The entire network of SNL/CA sanitary sewer lines, including building laterals, was identified as SWMU #16 under a Resource Conservation and Recovery Act (RCRA) Facility Assessment conducted for SNL/CA in April 1991 (DOE 1992). Along with the previous SWMU #16 investigation results (SNL/CA 2019), the results of this investigation are intended to support closure decisions by the San Francisco Bay Regional Water Quality Control Board (RWQCB), as discussed below. SNL/CA personnel completed upgrading its sanitary sewer discharge network in 2019. These upgrades included installing new sections of underground lines and decommissioning certain sections of the old piping system by capping in place. To date, several sections of the sewer line have been abandoned-in-place by capping as new sewer lines were installed or flow was rerouted to other existing lines. To formally close these abandoned sections of the sewer line, the RWQCB required that SNL/CA personnel collect soil samples to be analyzed for contaminants potentially released from the sewer lines. SNL/CA personnel hired Weiss Associates (Weiss) of Emeryville, California to prepare a sampling and analysis plan, implement the sampling plan and report the results of the investigation under Purchase Order #2166257. The Sampling and Analysis Plan for Partial Closure of Solid Waste Management Unit #16 (SAP) was submitted to the RWQCB on August 14, 2020 by Weiss on behalf of SNL/CA. The RWQCB approved the SAP on September 30, 2020 after Weiss updated the method detection limit and reporting limits for total polychlorinated biphenyls (PCBs) and individual aroclors. Soil sampling was conducted in accordance with the SAP except that fewer locations were sampled due to site constraints, as discussed below. This report presents the results of the sampling effort and documents all associated field activities including borehole clearing, soil sample collection, storage and transportation to the analytical laboratories, borehole backfilling and surface restoration, and storage of investigation-derived waste (IDW) for future profiling and disposal by SNL/CA waste management personnel.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Towards standardized nuclear reactors: Seismic isolation and the cost impact of the earthquake load case

We report nuclear energy has a key role to play in global decarbonization. Impediments to the widespread deployment of reactors are their projected high capital cost and levelized cost of energy, and time required to analyze, design, license, construct, and commission them. The earthquake load case is a key cost driver for a new build nuclear plant, because near-surface soils and seismic hazard are different at each site, requiring site-specific analysis, design, engineering, qualification, licensing, and regulatory review, essentially making every design First-of-a-Kind (FoaK). To enable deployment at the scale needed for deep decarbonization, the cost and time impact of the seismic load case must be significantly mitigated, and plants must be standardized. Seismic base isolation has been proven to considerably reduce the earthquake response of structures and equipment but has yet to be applied to a nuclear power plant in the United States, in part because the financial impacts, positive or negative, are not known. Because there are no recent non-proprietary data to characterize the influence of the seismic load case on capital cost, it is difficult to confidently quantify the financial benefits of seismic isolation. Scheme-level designs of two fundamentally different advanced reactor buildings were developed to assemble cost data on the influence of the seismic load case. Both buildings were equipped with three bespoke pieces of safety-related equipment and analyzed for incremented levels of earthquake shaking to quantify the seismic penalty on equipment, in terms of vessel weights and horizontal accelerations. Using analysis results, a questionnaire was developed and transmitted to nuclear utilities, reactor developers, engineers, and equipment suppliers to collect cost data on engineering and fabrication costs for these unique pieces of safety-class equipment. Synthesis of the cost data showed that the seismic load case significantly affects the capital cost (sum of engineering and fabrication cost) of safety-class equipment, with engineering costs being comparable to fabrication costs. Standardization of safety-class equipment is made possible by seismic isolation, that is, equipment designed for minimal seismic robustness can resist earthquake shaking at a site of much higher seismic hazard. The average reduction in the capital cost of the safety-related equipment, enabled by seismic isolation, is a factor of two for FoaK equipment and a factor of five for standardized equipment.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

The Psyche Gamma-Ray and Neutron Spectrometer

A Gamma-Ray and Neutron Spectrometer (GRNS) instrument has been developed as part of the science payload for NASA’s Discovery Program Psyche mission to the M-class asteroid (16) Psyche. The GRNS instrument is designed to measure the elemental composition of Psyche with the goal to understand the origin of this mysterious, potentially metal-rich planetary body. The GRNS will measure the near-surface abundances for the elements Ni, Fe, Si, K, S, Al, and Ca, as well as the spatial distribution of Psyche’s metal-to-silicate fraction (or metal fraction). These measurements address three of the five Psyche mission science objectives: determine if Psyche is a core; determine whether small metal bodies incorporate light elements into the metal phase; and determine whether Psyche was formed under reducing conditions. The Gamma-Ray Spectrometer (GRS) uses a cryocooled, high-purity Ge (HPGe) sensor to detect cosmic-ray generated gamma rays in the 60 to 9000-keV energy range. The HPGe sensor is surrounded by a borated plastic anticoincidence shield that provides three functions: active background rejection from charged particle interactions in the HPGe sensor; fast neutron measurements; and direct measurements of the incident galactic cosmic ray flux. The Neutron Spectrometer (NS) uses three 3 He gas proportional sensors, each with different material wraps to measure thermal (<0.4 eV), low-energy epithermal (0.4 eV to 1 keV), and high-energy epithermal (up to 100 keV) neutrons. This paper provides an overview of the Psyche GRNS, including: its science and measurement objectives; the design of the instrument hardware, software, and operation; pre-launch performance measurements and its initial performance in space; and an overview of its data products and expected operation for different Psyche mission phases.

Engineering - Instrumentation related to nuclear s↗

Ion-beam radiation-induced Eshelby transformations: The mean and variance in hydrostatic and shear residual stresses

Ion beam plays a pivotal role in ion implantations and the fabrication of nanostructures. However, there lacks a quantitative model to describe the residual stresses associated with the ion-beam radiation. Radiation-induced residual stress/transformation strain have been mostly recognized in the hydrostatic sub strain space. Here, in this study, we use molecular dynamics (MD) simulations to show that the response of a material to irradiation is generally anisotropic that depends on the ion-beam direction, and should be described using tensorial quantities. We demonstrate that accelerator-based ion beam irradiation, combined with the intrinsic lattice anisotropy and externally induced anisotropy (such as anisotropic mechanical loadings), causes radiation-actuated shear transformation strains in addition to hydrostatic expansion. We map out these complex correlations for several materials. Radiation-induced defects are shown to be responsible for residual shear stresses in the manner of Eshelby inclusion transformation. We propose such tensorial response model should be considered for accurate nanoscale fabrication using ion-beam irradiation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Detect and correct bias in multi-site neuroimaging datasets

The desire to train complex machine learning algorithms and to increase the statistical power in association studies drives neuroimaging research to use ever-larger datasets. The most obvious way to increase sample size is by pooling scans from independent studies. However, simple pooling is often ill-advised as selection, measurement, and confounding biases may creep in and yield spurious correlations. In this work, we combine 35,320 magnetic resonance images of the brain from 17 studies to examine bias in neuroimaging. In the first experiment, Name That Dataset, we provide empirical evidence for the presence of bias by showing that scans can be correctly assigned to their respective dataset with 71.5% accuracy. Given such evidence, we take a closer look at confounding bias, which is often viewed as the main shortcoming in observational studies. In practice, we neither know all potential confounders nor do we have data on them. Hence, we model confounders as unknown, latent variables. Kolmogorov complexity is then used to decide whether the confounded or the causal model provides the simplest factorization of the graphical model. Finally, we present methods for dataset harmonization and study their ability to remove bias in imaging features. In particular, we propose an extension of the recently introduced ComBat algorithm to control for global variation across image features, inspired by adjusting for unknown population stratification in genetics. Overall, our results demonstrate that harmonization can reduce dataset-specific information in image features. Further, confounding bias can be reduced and even turned into a causal relationship. However, harmonization also requires caution as it can easily remove relevant subject-specific information. Code is available at https://github.com/ai-med/Dataset-Bias.

42 ENGINEERING↗

A pathway to synthesizing single-crystal Fe and FeCr films

Nuclear reactor environments provide a unique scientific and engineering challenge wherein materials must tolerate prolonged exposure to concurrent irradiation, elevated temperatures, and corrosive media. However, uncontrolled variability in material composition and structure often prohibits truly single-variable experiments that can reveal basic aspects of environmental damage. Here, Magnetron sputtering is used to provide a more controlled model system for these fundamental studies, yielding reproducible single-crystal Fe and FeCr thin films containing 8 and 18 at.% Cr. Electron microscopy is used to determine the systematic correlations between growth conditions and the resulting film microstructure and surface morphology. It is found that the substrate temperature and applied radio frequency (RF) bias can be tuned to obtain consistent homogeneous and single crystal films with a minimal amount of Ar impurities from the RF bias process. Epitaxial, single-crystal Fe films are obtained on MgO substrates at 500 °C with 10 Watt (W) RF bias deposition. However, when Cr is alloyed with Fe, higher substrate temperatures (600 °C) and applied RF biases (15 W) are required to achieve a similar epitaxial single-crystal FeCr film. Accelerated molecular dynamics simulations reveal that Cr impedes surface transport, explaining the need for higher temperature and bias during the growth of the Cr-bearing films.

36 MATERIALS SCIENCE↗

Tunnel oxide passivating contact enabled by polysilicon on ultra-thin SiO 2 for advanced silicon radiation detectors

Conventional silicon junction detectors encounter significant carrier recombination within the heavily doped p⁺ and n⁺ layers, as well as beneath the metal contact regions, creating the so-called “dead layers”, especially on the detector side. In this study, we present the tunnel oxide passivating contact with doped polysilicon on oxide, which demonstrates exceptional surface passivation and carrier selectivity. The key innovation lies in an ultra-thin (~ 1.5 nm) interfacial oxide layer that facilitates efficient majority carrier transportation via tunneling while effectively block minority carriers. Remarkably low saturation current densities, ranging from 5 to 10 fA/cm² even with the metal contact, underscore the superiority of both n-type and p-type tunnel oxide passivating contacts. In contrast, conventional p–n junction or high-low junction exhibit saturation current densities ranging from 10 to 90 fA/cm² in the studied p⁺ and n⁺ layers with surface passivation schemes due to Auger recombination and surface recombination, and 1000–6000 fA/cm² with metal contacts due to intense metal-induced recombination at the interface. These findings indicate the potential and superiority of implementing n-type tunnel oxide passivating contact on the detector side and p-type contact on the back side for advanced silicon radiation detectors. This approach would enable thorough collection of generated charge carriers along the track of incident ionizing radiation particles, leading to improved energy resolution and reduced noise levels.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization of the hardened single line of sight camera at the National Ignition Facility

The hardened single line of sight camera has been recently characterized in preparation for its deployment on the National Ignition Facility. The latest creation based on the pulse-dilation technology leads to many new features and improvements over the previous-generation cameras to provide better quality measurements of inertial confinement fusion experiments, including during high neutron yield implosions. Here, we present the characterization data that illustrate the main performance features of this instrument, such as extended dynamic range and adjustable internal magnification, leading to improved spatial resolution.

Trosseille, C. (ORCID:0000000289430482)↗

Electrochemistry of PUREX: R is for Reduction and Ion Transfer

The PUREX (Plutonium, Uranium, Reduction, EXtraction) process is the foundation of all industrial activities that involve the recycling of plutonium and uranium from used nuclear fuel. With over 70 years of research, engineering, and operations, it can be argued that little opportunity is left for further discovery and new fundamental understandings regarding PUREX, in general, and tri-n-butyl phosphate (TBP), in particular. Through use of an advanced electroanalytical approach, molecular-level insights regarding the back-extraction of Pu(IV) by reductive separation is reported. Studies of model PUREX systems, with lanthanide ions extracted into 20 % TBP in n-dodecane, are used to demonstrate the approach. These studies reveal knowledge pertinent to mass transfer aspects of the biphasic reductive stripping reaction central to the separation of U and Pu in PUREX. Two lanthanide ions—Ce(IV) and Yb(III)—were extracted from their concentrated solutions in aqueous 3 M HNO 3 to expressly provide electrically conducting third phases to facilitate electrochemical data acquisition. To simplify the diabolically-complicated reductive separation aspects of PUREX, the controlled polarization of electrode surfaces was used to reduce Ce(IV) and Yb(III) in place of chemical reductants. Electroanalyses of the biphasic systems with Ce(IV) and Yb(III) using three-phase electrode differential pulse voltammetry demonstrate the effects of mass transfer across water-oil interfaces on the electrode potentials for the reduction to Ce(III) and Yb(II). These reductions trigger nitrate transfer out of the oil phase for Ce and proton transfer into the organic phase for Yb. This is in correlation with the transfer of the charge-neutral ion pairs Ce·3NO 3 and Yb·2NO 3 out of the oil phases. Here, the differences in ion transfer steps reflect significant variations in the equilibrium speciation of multinuclear Ce(IV) and mononuclear Yb(III) solvates of TBP in the oil phases and the loading of the organic phase.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Weapons Production Directorate Overview

Detonator Production and Prototype Fabrication divisions serve a variety of organizations throughout the Laboratory and the nation by providing key non-nuclear components through excellence in on-site engineering, design, manufacturing, machining, and more.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗