Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Neutron Detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,351 records · Page 75

Scientific objectives and first results from COMPTEL

The imaging Compton telescope (COMPTEL) is the first imaging telescope in space to explore the MeV gamma ray range. At present it is performing a complete sky survey. In later phases of the mission, selected celestial objects will be studied in more detail. Targets of special interest in the COMPTEL energy range are radio pulsars, X-ray binaries, novae, supernova remnants, molecular clouds, and the interstellar medium within the Milky Way, as well as the nuclei of active galaxies, supernovae, and the diffuse cosmic background radiation in extragalactic space. The first four months of operation demonstrated that COMPTEL basically performs as expected. The Crab is clearly seen at its proper position in the first images of the anticenter region of the Galaxy. The Crab pulsar lightcurve was measured with unprecedented accuracy. The quasar 3C273 was seen for the first time at MeV-energies. Several cosmic bursts within the COMPTEL field of view could be located to an accuracy of about 1 degree. On June 9, 11, and 15, 1991 COMPTEL observed gamma ray (continuum and line) emission from three solar flares. Neutrons were also detected from the June 9 flare. At the present state of analysis, COMPTEL achieves the prelaunch predictions of its sensitivity within a factor of 2. Based on the present performance of COMPTEL, the team is confident that COMPTEL will fulfill its primary mission of surveying and exploring the MeV sky.

Schoenfelder, V.↗

Broadband High-Energy Observations of the Superluminal Jet Source GRO J1655-40 During an Outburst

The X-ray/radio transient superluminal jet source GRO J1655-40 was recently suggested to contain a black hole from optical observations. Because it is a relatively close-by system (d approximately 3.2 kpc), it can likely provide us with rich information about the physics operating in both Galactic and extragalactic jet sources. We present the first simultaneous broadband high-energy observations of GRO J1655-40 during the 1995 July-August outburst by three instruments: ASCA, WATCH/Granat, and BATSE/CGRO, in the energy band from 1 keV to 2 MeV. Our observations strengthen the interpretation that GRO J1655-40 contains a black hole. We detected a two-component energy spectrum, commonly seen from other Galactic black hole binaries, but never detected from a neutron star system. Combining our results with the mass limits derived from optical radial velocity and orbital period measurements, we further constrain the mass of the central object to be between 3.3 and 5.8 solar mass, above the well-established mass upper limit of 3.2 solar mass for a neutron star (the optical mass function for GRO J1655-40 is 3.16 + 0.2 solar mass). This system is therefore the first Galactic superluminal jet source for which there is strong evidence that the system contains a stellar mass black hole. The inclination angle of the binary system is constrained to be between 76 deg and 87 deg, consistent with estimates obtained from optical light curves and radio jet kinematics.

Zhang, S. N.↗

Observations of the Neuton Star RXJ0002.9 + 6246

The High Resolution Imager (HRI) observation of the CTB1 region requested in the original proposal was performed and data received. The primary target, the candidate neutron star, was detected at the predicted intensity. As proposed, both timing and spatial extent analysis has been performed on the extracted photons. The preliminary timing analysis showed no evidence for the faint pulsations seen in the PSPC data. As the pulse fraction was rather small, this was not an unexpected result. We have, however, recently developed more sophisticated timing analysis capabilities and are in the process of reanalyzing the data to more accurately constrain the pulse fraction, if indeed any evidence for pulsation is found. We have supplemented the HRI observations with optical observations. Filter images, in BVR & I, have been obtained as well as spectra for candidate counterparts. As of this writing, the original analysis holds, i.e. the x-ray flux is not consistent with the L(sub x)/L(sub opt) ratios expected from the candidate stars within the 3 sigma positional error circles. HRI confirmation of the flux as well as the refinement of the position have allowed us to limit the candidate list and refine the original L(sub x)/L(sub opt) analysis.

Hailey, Charles J.↗

Discovery of a 450 Hz Quasi-Periodic Oscillation from the Microquasar GRO J1655-40 with the Rossi X-ray Timing Explorer

We report the discovery with the Proportional Counter Array on board the Rossi X-Ray Timing Explorer of a 450 Hz quasi-periodic oscillation (QPO) in the hard X-ray flux from the Galactic microquasar GRO J1655-40. This is the highest frequency QPO modulation seen to date from a black hole. The QPO is detected only in the hard X-ray band above approx. 13 keV. It is both strong and narrow, with a typical rms (root mean square) amplitude of 4.5% in the 13-27 keV range and a width of approx. 40 Hz (FWHM). For two observations in which we detect the 450 Hz QPO, a previously known approx. 300 Hz QPO is also observed in the 2-13 keV band. We show that these two QPOs sometimes appear simultaneously, thus demonstrating the first detection of a pair of high-frequency QPOs in a black hole system. Prior to this, pairs of high-frequency QPOs have been detected only in neutron star systems. GRO J1655-40 is one of only a handful of black hole systems with a good dynamical mass constraint. For a nonrotating black hole with mass between 5.5 and 7.9 solar masses, the innermost stable circular orbit (ISCO) ranges from 45 to 70 km. For any mass in this range the radius at which the orbital frequency reaches 450 Hz is less than the ISCO radius, indicating that, if the modulation is caused by Kepler motion, the black hole must have appreciable spin. If the QPO frequency is set by the orbital frequency of matter at the ISCO, then for this mass range the dimensionless angular momentum lies in the range 0.15 < j < 0.5. Moreover, if the modulation is caused by oscillation modes in the disk or Lense-Thirring precession, then this would also require a rapidly rotating hole. We briefly discuss the implications of our findings for models of X-ray variability in black holes and neutron stars.

Strohmayer, Tod E.↗

Population Studies of Radio and Gamma-Ray Pulsars

Rotation-powered pulsars are one of the most promising candidates for at least some of the 40-50 EGRET unidentified gamma-ray sources that lie near the Galactic plane. Since the end of the EGRO mission, the more sensitive Parkes Multibeam radio survey has detected mere than two dozen new radio pulsars in or near unidentified EGRET sources, many of which are young and energetic. These results raise an important question about the nature of radio quiescence in gamma-ray pulsars: is the non-detection of radio emission a matter of beaming or of sensitivity? The answer is very dependent on the geometry of the radio and gamma-ray beams. We present results of a population synthesis of pulsars in the Galaxy, including for the first time the full geometry of the radio and gamma-ray beams. We use a recent empirically derived model of the radio emission and luminosity, and a gamma-ray emission geometry and luminosity derived theoretically from pair cascades in the polar slot gap. The simulation includes characteristics of eight radio surveys of the Princeton catalog plus the Parkes MB survey. Our results indicate that EGRET was capable of detecting several dozen pulsars as point sources, with the ratio of radio-loud to radio-quiet gamma-ray pulsars increasing significantly to about ten to one when the Parkes Survey is included. Polar cap models thus predict that many of the unidentified EGRET sources could be radio-loud gamma- ray pulsars, previously undetected as radio pulsars due to distance, large dispersion and lack of sensitivity. If true, this would make gamma-ray telescopes a potentially more sensitive tool for detecting distant young neutron stars in the Galactic plane.

Harding, Alice K↗

A Year in the Life of GW 170817: The Rise and Fall of a Structured Jet from a Binary Neutron Star Merger

We present the results of our year-long afterglow monitoring of GW 170817, the first binary neutron star merger detected by Advanced Laser Interferometer Gravitational-Wave Observatory (LIGO) and Advanced Virgo. New observations with the Australian Telescope Compact Array and the Chandra X-ray Telescope were used to constrain its late-time behaviour. The broad-band emission, from radio to X-rays, is well-described by a simple power-law spectrum with index β ∼ 0.585 at all epochs. After an initial shallow rise ∝t0.9, the afterglow displayed a smooth turnover, reaching a peak X-ray luminosity of LX ≈ 5 × 1039 erg s−1 at 160 d, and has now entered a phase of rapid decline, approximately ∝t−2. The latest temporal trend challenges most models of choked jet/cocoon systems, and is instead consistent with the emergence of a relativistic structured jet seen at an angle of ≈22◦ from its axis. Within such model, the properties of the explosion (such as its blast wave energy EK ≈ 2 × 1050 erg, jet width θc ≈ 4◦, and ambient density n ≈ 3 × 10−3 cm−3) fit well within the range of properties of cosmological short gamma-ray bursts.

Acceleration of particles↗

Fermi Gamma-ray Space Telescope

The Fermi Gamma-ray Space Telescope, a key mission in multiwavelength and multimessenger studies, has been surveying the γ-ray sky from its low-Earth orbit since 2008. Its two scientific instruments, the Gamma-ray Burst Monitor (GBM) and the Large Area Telescope (LAT), cover 8 orders of magnitude in photon energy. The GBM consists of 12 Sodium Iodide detectors and 2 Bismuth Germinate detectors, covering the 10 keV - 40 MeV energy range, arrayed on two sides of the spacecraft so as to view the entire sky that is not occulted by the Earth. The LAT is a pair production telescope based on silicon strip trackers, a Cesium Iodide calorimeter, and a plastic scintillator anticoincidence system. It covers the energy range from about 20 MeV to more than 500 GeV, with a field of view of about 2.4 steradians. Thanks to their huge fields of view, the instruments can observe the entire sky with a cadence of about an hour for GBM and about three hours for LAT. All γ-ray data from Fermi become public immediately, enabling a broad range of multiwavelength and multimessenger research. Over 3000 γ-ray bursts (GRBs), including GRB 170817A associated with a neutron star merger detected in gravitational waves, and 5000 high-energy sources, including the blazar TXS 0506+056 associated with high-energy neutrinos, have been detected by the Fermi instruments. The Fermi Science Support Center provides a wide array of resources to enable scientific use of the data, including background models, source catalogs, analysis software, documentation, and a Help Desk.

gamma rays↗

The Capabilities of the upgraded MIPP experiment with respect to Hypernuclear physics

We describe the state of analysis of the MIPP experiment, its plans to upgrade the experiment and the impact such an upgraded experiment will have on hypernuclear physics. The upgraded MIPP experiment is designed to measure the properties of strong interaction spectra form beams {pi}{sup {+-}}, K{sup {+-}}, and p{sup {+-}}, for momenta ranging from 1 GeV/c to 120 GeV/c. The layout of the apparatus in the data taken so far can be seen in Figure 1. The centerpiece of the experiment is the time projection chamber, which is followed by the time of flight counter, a multi-cell Cerenkov detector and the RICH detector. The TPC can identify charged particles with momenta less than 1 GeV/c using dE/dx, the time of flight will identify particles below approximately 2 GeV/c, the multi-cell Cerenkov detector is operational from 2.5 GeV/c to 14 GeV/c and the RICH detector can identify particles up to 120 GeVc. Following this is an EM and hadronic calorimeter capable of detecting forward going neutrons and photons. The experiment has been busy analyzing its data taken on various nuclei and beam conditions. The table 2 shows the data taken by MIPP I to date. We have almost complete acceptance in the forward hemisphere in the lab using the TPC. The reconstruction capabilities of the TPC can be seen in Figure 3. The particle identification capabilities of the TPC can be seen in Figure 4. The time of flight system provides further measurement of the particles with momenta less than 2 GeV/c. Figure 5 shows the time of flight data where a kaon peak is clearly visible.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A radial collimator for a time-of-flight neutron spectrometer

We have engineered and installed a radial collimator for use in the scattered beam of a neutron time-of-flight spectrometer at a spallation neutron source. The radial collimator may be used with both thermal and epithermal neutrons, reducing the detected scattering intensity due to material outside of the sample region substantially. The collimator is located inside of the sample chamber of the instrument, which routinely cycles between atmospheric conditions and cryogenic vacuum. The oscillation and support mechanism of the collimator allow it to be removed from use without breaking vacuum. We describe here the design and characterization of this radial collimator.

Stone, Matthew B↗

Observations of GW170817 by DESGW and the DECam GW-EM Collaboration

On August 17, 2017 LIGO/Virgo detected a binary neutron star via gravitational waves. We observed 70 sq-degrees in the LIGO/Virgo spatial localization with the DECam on the 4m Blanco telescope covering 80% of the nal map. Our group independently discovered an optical counterpart in NGC 4993. We searched our entire imaged region: the object in NGC 4993 was the only viable candidate. Our observations of NGC4993 show complicated morphology but simple star formation history. Our x-ray and radio observations indicate an o-axis jet as afterglow. Our high-cadence optical and infrared spectra show a source that must be described by at least two components, one of which is dominated by the r-process nucleosynthesis elements characteristic of a kilonova. Our modeling of the light curve demonstrates such a model in which 0.05 M of material is ejected from the system. Finally, we discuss the first standard siren measurement of H0.

Annis, James↗

Fissile Material Detection by Differential Die Away Analysis

Detection and interdiction of Special Nuclear Material (SNM) in transportation is one of the most critical security issues facing the United States. Active inspection by inducing fission in fissile nuclear materials, such as {sup 235}U and {sup 239}Pu, provides several strong and unique signatures that make the detection of concealed nuclear materials technically very feasible. Differential Die-Away Analysis (DDAA) is a very efficient, active neutron-based technique that uses the abundant prompt fission neutrons signature. It benefits from high penetrability of the probing and signature neutrons, high fission cross section, high detection sensitivity, ease of deployment and relatively low cost. DDAA can use any neutron source or energy as long as it can be suitably pulsed. The neutron generator produces pulses of neutrons that are directed into a cargo. As each pulse passes through the cargo, the neutrons are thermalized and absorbed. If SNM is present, the thermalized neutrons create a new source of (fission) neutrons with a distinctive time profile. An efficient laboratory system was designed, fabricated and tested under a US Government DHS DNDO contract. It was shown that a small uranium sample can be detected in a large variety of cargo types and configurations within practical measurement times using commercial compact (d,T) sources. Using stronger sources and wider detector distribution will further cut inspection time. The system can validate or clear alarms from a primary inspection system such as an automated x-ray system.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Measurement of the Fast Neutron Response for {sup 4}He Scintillation Detectors Using a Coincidence Scattering Method

Previous work has measured the neutron response of pressurized {sup 4}He scintillation detectors, however these studies only examine the response as a function of incident neutron energy. Since the detection mechanism in {sup 4}He detectors is elastic scattering, and the interacting neutron will only deposit a fraction of its incident kinetic energy in the detector gas, an examination of the response of the detector output to deposited energy is necessary to transform these detectors into instruments for neutron spectrometry. Using a combined time-of-flight (TOF) and coincidence scattering method, this paper further characterizes the {sup 4}He light response to fast neutrons by examining the scintillation light yield as a function of deposited energy, measuring the light response up to 5 MeV. These {sup 4}He detectors are simple in design, and are manufactured by Arktis Radiation Detectors in several sizes. The specific model used in this experiment had an active volume 20 cm long with an inner diameter of 4.4 cm, giving a total active volume of 304 cm{sup 3}. The key components include the active volume, filled with 150 bar of helium-4 gas, and photomultiplier tubes (PMTs) mounted at either end of the active volume. The detector body is made of stainless steel. The detector response was experimentally measured using a two-detector coincidence arrangement with a {sup 252}Cf source. Two {sup 4}He detectors were vertically mounted, and the source was placed at a horizontal distance from the center of the bottom detector, forming a right angle. By requiring coincidence between the two detectors, it was confirmed that each neutron interacting in the second (top) detector must first have undergone a scattering interaction in the first (bottom) detector, and the time-of-flight (TOF) technique could then be used to determine the energy of the neutron as it traveled between the two detectors by the difference in time between the two detector events. More importantly, with the scattering angle known, the amount of energy deposited by the neutron in the bottom detector (ER) was also calculated using kinematic scattering equations. This deposited recoil energy was then compared to the corresponding light output for each event to form a deposited energy scintillation light response matrix. Similarly, the system's insensitivity to gammas and its ability to reject gammas by pulse shape discrimination (PSD) are often cited as an important advantage, although a detailed analysis of these capabilities has not yet been performed. This work therefore quantified these parameters in order to further characterize these detectors for future mixed radiation field measurements. Gamma sources were measured spanning a range of gamma-ray energies from 0.122 MeV to 1.332 MeV, including {sup 57}Co, {sup 137}Cs, {sup 54}Mn, and {sup 60}Co. Each source was counted by the {sup 4}He detector and the background subtracted. Taking the ratio of the number of events detected during the experimental source measurement to the number of gammas predicted by MCNPX to pass through the detector volume yields the detector's intrinsic gamma efficiency. The difference between this fraction and unity is therefore a measure of the detector's ability to ignore interfering gamma rays, defined as its inherent gamma rejection rate. The ability of post-processing PSD algorithms to further reduce the number of gammas is also investigated and quantified. Finally, it has been noted that the scintillation signal from a single neutron event can be separated in time into two components: the fast component is a sharp peak that exists on the order of nanoseconds; the slow component is a series of smaller pulses, stretched out over four microseconds. Whereas previous research has exclusively focused on the energy information contained in the slow component, this work demonstrates that the fast component is also sensitive to neutron energy, and the entire scintillation signal can therefore be used. In conclusion, the relationship of fast neutron {sup 4}He scintillation detectors to deposited neutron energy was explored, and will be combined with previous works that measured the scintillation response to incident neutron energy in order to develop a neutron spectrometer. Similarly, the ability of these {sup 4}He detectors to reject interfering gamma rays was also quantified, and so will enable this spectrometer to be deployed in mixed radiation field measurements. Finally, while previous works with these detectors have focused on an analysis of the slow scintillation component, it was demonstrated in this work that the fast component also contains significant energy information.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Container inspection in the port container terminal by using 14 MeV neutrons

A proposal for an autonomous and flexible ship container inspection system is presented. This could be accomplished by the incorporation of inspection system on the container transportation devices (straddle carriers, yard gentry cranes automated guided vehicles, trailers). This configuration is terminal specific and it will be decided by container terminal operator. In such a way no part of port operational area will be used for inspection. The inspection scenario will include container transfer from ship to transportation device with inspection unit mounted on it, inspection during container movement to the container location. A neutron generator without associated alpha particle detection will be used. This will allow the use of higher neutron intensity (5x10{sup 9} - 10{sup 10} n/s in 4π). The inspected container will be stationary in the 'inspection position' on the transportation device while the 'inspection unit' will move along its side. Following analytical methods will be used simultaneously: neutron radiography, X-ray radiography, neutron activation analysis, (n,γ) and (n,n'γ) reactions, neutron absorption, and scattering, X-ray backscattering, Neutron techniques will take the advantage of using 'smart collimators' for neutrons and gammas, both emitted and detected. The inspected voxel will be defined by intersections/union of neutron generator and detectors solid angles. The container inspection protocol will be based on identification of discrepancies between its cargo manifest and its elemental 'fingerprint' and radiography profiles. In addition, the information on container weight will be obtained during the container transport and foreseen screening from the measurement of density of material in the container. (authors)

42 ENGINEERING↗

ALPHANSO: Open-source modeling of (α, n) neutron source terms

Applications ranging from nuclear safeguards to dark matter detection require accurate predictions of neutron yields and energy spectra produced by (α, n) reactions. Legacy tools like SOURCES-4C remain widely used despite significant limitations, including outdated nuclear data, missing target nuclides, and restricted accessibility. Here, we present ALPHANSO, an open-source Python package for calculating (α, n) neutron source terms. ALPHANSO incorporates modern nuclear data libraries and formats covering all naturally occurring target nuclides and provides a transparent, modular framework for updating or extending the data as new evaluations are released. Comparison with an updated version of SOURCES-4A, NeuCBOT, and experimental measurements across a range of elements and materials shows that ALPHANSO reproduces neutron yields and spectra in good agreement with experimental data and state-of-the-art (α, n) calculations. These results demonstrate that ALPHANSO is a reliable, accessible, and modern alternative to legacy (α, n) source term codes such as SOURCES-4C. Its open-source design and modular data handling make it readily extensible to future evaluated nuclear data and low-background applications.

(α, n) reactions↗

Identification of Fissionable Materials Using the Tagged Neutron Technique

This summary describes experiments to detect and identify fissionable materials using the tagged neutron technique. The objective of this work is to enhance homeland security capability to find fissionable material that may be smuggled inside shipping boxes, containers, or vehicles. The technique distinguishes depleted uranium from lead, steel, and tungsten. Future work involves optimizing the technique to increase the count rate by many orders of magnitude and to build in the additional capability to image hidden fissionable materials. The tagged neutron approach is very different to other techniques based on neutron die-away or photo-fission. This work builds on the development of the Associated Particle Imaging (API) technique at the Special Technologies Laboratory (STL) [1]. Similar investigations have been performed by teams at the Oak Ridge National Laboratory (ORNL), the Khlopin Radium Institute in Russia, and by the EURITRACK collaboration in the European Union [2,3,4].

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SONTRAC: A solar neutron track chamber detector

The recent detection on the solar maximum mission (SMM) satellite of high energy neutrons emitted during large solar flares has provided renewed incentive to design a neutron detector which has the sensitivity, energy resolution, and time resolution to measure the neutron time and energy spectra with sufficient precision to improve our understanding of the basic flare processes. Over the past two decades a variety of neutron detectors has been flown to measure the atmospheric neutron intensity above 10 MeV and to search for solar neutrons. The SONTRAC (Solar Neutron Track Chamber) detector, a new type of neutron detector which utilizes n-p scattering and has a sensitivity 1-3 orders of magnitude greater than previous instruments in the 20-200 MeV range is described. The energy resolution is 1% for neutron kinetic energy, T sub n 50 MeV. When used with a coded aperture mask at 50 m (as would be possible on the space station) an angular resolution of approx. 4 arc sec could be achieved, thereby locating the sites of high energy nuclear interactions with an angular precision comparable to the existing x-ray experiments on SMM. The scintillation chamber is investigated as a track chamber for high energy physics, either by using arrays of scintillating optical fibers or by optical imaging of particle trajectories in a block of scintillator.

Frye, G. M., Jr.↗

SU-F-J-196: A Prototype System for Portal Imaging for Intensity Modulated Neutron Therapy

Purpose: Fast neutron therapy is offered at the University of Washington Medical Center for treatment of selected cancers. The hardware and control systems of the UW Clinical Neutron Therapy System are undergoing upgrades to enable delivery of IMNT. To clinically implement IMNT, dose verification tools need to be developed. We propose a portal imaging system that relies on the creation of positron emitting isotopes ({sup 11}C and {sup 15}O) through (n, 2n) reactions with a PMMA plate placed below the patient. After field delivery, the plate is retrieved from the vault and imaged using a reader that detects the annihilation photons. The pattern of activity produced in the plate provides information to reconstruct the neutron fluence map that can be compared to fluence maps from Monte Carlo (MCNP) simulations to verify treatment delivery. We have previously performed Monte Carlo simulations of the portal imaging system (GATE simulations) and the beam line (MCNP simulations). In this work, initial measurements using a prototype system are presented. Methods: Custom electronics were developed for BGO detectors read out with photomultiplier tubes (previous generation PET detectors from a CTI ECAT 953 scanner). Two detectors were placed in coincidence, with a detector separation of 2 cm. Custom software was developed to create the crystal look up tables and perform a limited angle planar reconstruction with a stochastic normalization. To test the initial capabilities of the system, PMMA squares were irradiated with neutrons at a depth of 1.5 cm and read out using the prototype system. Doses ranging from 10–200 cGy were delivered. Results: Using the prototype system, dose differences in the therapeutic range could be determined. Conclusion: The prototype portal imaging system is capable of detecting neutron doses as low as 10–50 cGy and shows great promise as a patient QA tool for IMNT.

60 APPLIED LIFE SCIENCES↗

Testing The High-Energy Prompt Neutron Signature At Low Beam Energies

Prompt fission neutrons continue to be examined as a signature for detecting the presence of fissionable material. This technique exploits the neutron energy limitations inherent with photonuclear emissions from non-fissionable material, allowing prompt fission neutrons to be identified and engaged for detecting nuclear material. Prompt neutron signal measurements were acquired with bremsstrahlung endpoint energies of 6 MeV for 18 targets comprised of both fissionable and non-fissionable material; delayed neutron measurements were also collected as a reference. The {sup 238}U target was also shielded with increasing thicknesses of lead or borated polyethylene to compare the resulting detection rates of the prompt and delayed fission neutron signals.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗