Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Multiplex”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,351 records · Page 75

Design and performance of an in-vacuum, magnetic field mapping system for the Muon g-2 experiment

The E989 Muon g-2 experiment at Fermilab aims to measure the anomalous magnetic moment, a$_\mu$, of the muon with a precision of 140 parts-per-billion. This requires a precise measurement of both the anomalous spin precession frequency, $\omega_a$, and the average magnetic field in terms of the equivalent, free proton Larmor frequency, $\omega_p$. The measurement of $\omega_p$ with a total systematic uncertainty of 70 parts-per-billion involves a combination of various NMR probes. There are 378 probes in fixed locations constantly monitoring field drifts. A water-based probe provides the calibration in terms of $\omega_p$. A crucial element for the multi-step measurement of $\omega_p$ is the regular mapping of the magnetic field over the muon storage region. The former E821 experiment at Brookhaven employed an in-vacuum field mapping system equipped with 17 NMR probes, which was developed by the University of Heidelberg. We have refurbished and upgraded this system with new probes and electronics. The upgrades include a new communication scheme incorporating time-division multiplexing to separate the important NMR reference clock from the data communication. The addition digitization of the NMR signals replaced the hardware-implemented zero-crossing counting of the E821 system. The digitized signals offer new capabilities in the NMR frequency analysis and its related systematic uncertainties. While the mechanical systems that move the field mapper around the ring have been mostly refurbished, the motion control system was completely replaced with a custom-built electronics centered around a commercial Galil motion controller. Both the field mapping NMR system and its motion control were successfully commissioned at Fermilab and have been in reliable operation during the first data taking periods. This article provides details of the upgrades of the field mapper and its performance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Multi-Sample Residual Resistivity Ratio System for High Quality Superconductor Measurements

For developing accelerator cavity materials, superconducting transition temperature (TC), transition width (ΔTC), and residual resistivity ratio (RRR), are useful parameters to correlate with SRF performance and fabrication processes of bulk, thin film, and novel materials. The RRR gauges the purity and structure of the superconductor based on the temperature dependence of electron scattering in the normal conducting state. Combining a four point probe delta pulse setup with a switch allows multiplexing of the electrical measurements to 32 samples per cooldown cycle. The samples are measured inside of an isothermal setup in a liquid helium (LHe) dewar. The isothermal setup is required for a quasistatic warmup of the samples through TC. This contribution details the current setup for collecting RRR and TC data, the current standard of throughput, measurement quality of the setup, and the improvements underway to increase the system’s resolution and ease of use.

Spradlin, J. K.↗

Fluid delivery manifolds and microfluidic systems

Embodiments of fluid distribution manifolds, cartridges, and microfluidic systems are described herein. Fluid distribution manifolds may include an insert member and a manifold base and may define a substantially closed channel within the manifold when the insert member is press-fit into the base. Cartridges described herein may allow for simultaneous electrical and fluidic interconnection with an electrical multiplex board and may be held in place using magnetic attraction.

42 ENGINEERING↗

HERMAN, the Nanoparticle Robot (360 video)

Science in 360°: Say hello to HERMAN, a robot that accelerates the synthesis of nanoparticles for a wide range of cool applications such as biosensors, smart window coatings, and display technologies. HERMAN (aka High-throughput Experimentation Robot for the Multiplexed Automation of Nanochemistry) is a one-of-a-kind robot at Berkeley Lab's Molecular Foundry that brings parallel processing and an extreme level of precision to the materials discovery process.

47 OTHER INSTRUMENTATION↗

Research plan for the development of optical fiber pressure sensors for nuclear applications

Fiber optic pressure sensors are desirable for nuclear applications because they are low mass/small size, immune to electromagnetic interference, high sensitivity, and have multiplexing and multimodal measurement capabilities. Much research and development has been conducted on developing fiber optic based sensors and they are now considered a class of standard instrumentation in many industries. Specifically, for pressure sensing, a wide range of fiber based sensors have been developed for various pressure ranges and environments. This vast body of research will be leveraged for the development of pressure sensors for nuclear applications. Four pressure measurement scenarios were considered which would benefit from a fiber optic based pressure sensor. These scenarios include pressure measurement in the fuel rod plenum, coolant pressure during LOCA testing, advanced coolant (helium, sodium, molten salt) pressure for flow loop operation, and high pressures resulting for direct fuel-coolant interaction. Each scenario has unique pressure, temperature, and material requirements for the sensor. From a survey of commercially available sensors and a literature review; it has been determined that an extrinsic Fabry-Perot interferometer approach is the most appropriate for the various measurement requirements. The experience and knowledge base for Fabry-Perot interferometers can be leveraged since they are the most common fiber optic based pressure sensors available commercially and found in literature. These pressure sensors rely on the interference of light in a gas filled cavity, which minimizes the impact of radiation induced attenuation and compaction on the measurement, compared to intrinsic sensing techniques. The measurement range of these sensors is based on the stiffness of the diaphragm that deflects under pressure. This allows for a suite of fiber based sensors to be developed by interchanging this diaphragm for the requirements of each application. Key material and design considerations have been identified for the development of a Fabry-Perot interferometry pressure measurement for nuclear applications. These include high temperature bonding between the glass fiber optic and metal housing, identifying diaphragm materials & geometry, and minimizing cross sensitivity to temperature or implementing compensation techniques found in literature. Overcoming these challenges will develop a pathway for a fiber optic based pressure sensor for nuclear applications, and additionally can be leveraged for other sensing application based on Fabry-Perot interferometers, such as temperature, strain (creep & deformation), vibration, and index of refraction.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Cyclic Prefix Direct Sequence Spread Spectrum Capacity Analysis

Cyclic Prefix Direct Sequence Spread Spectrum (CP-DSSS) is a novel waveform that has the potential to solve 5G objectives such as ultra reliable low latency communication (URLLC) and massive machine Type Communication (mMTC). This paper analyzes the capacity of the CP-DSSS waveform in comparison with Orthogonal Frequency Domain Multiplexing OFDM). CP-DSSS can be optimized to achieve the same capacity as OFDM when optimized by the water-filling algorithm. A significant advantage for CP-DSSS is that this capacity can be achieved with all symbols being transmitted with the same effective rate. As a result, stronger forward error correction codes can be used in a CP-DSSS implementation compared to an OFDM implementation with resource block constraints. In addition, the applicability of CP-DSSS as a waveform for a secondary network operating in the same frequency band as the primary network is discussed.

5G and Beyond Communications↗

CP-DSSS: An OFDM Compatible Variable Rate Modulation for 5G and Beyond

Cyclic prefix direct sequence spread spectrum (CPDSSS) is a recently proposed waveform that has been designed for coexistence with OFDM (orthogonal frequency division multiplexing) in the same or a pair of parallel networks. The first contribution of this paper is to present equations that reveal similarities and differences of CP-DSSS and OFDM. Furthermore, we show that the channel model of CP-DSSS reduces to that of a cyclic prefixed block-wise single carrier modulation (CP-SCM). However, unlike CP-SCM whose symbol rate is always equal to the transmission bandwidth, CP-DSSS can be adopted to any symbol rate equal to or smaller than the transmission bandwidth. This reduction in symbol rate allows CP-DSSS power spectral density to drop to an arbitrarily low level, hence, facilitates it coexistence as a secondary waveform in a network of primary users. The peak-to-average power ratio (PAPR) of CP-DSSS is also explored and a method for reducing it is proposed.

5G↗

Optical encoder devices and systems

Devices, systems and methods for encoding information using optical components are described. Information associated with a first optical signal (e.g., an optical pump) is encoded onto the phase of a second optical signal (e.g., an optical probe) using cross phase modulation (XPM) in a non-linear optical medium. The optical signals are multiplexed together into the nonlinear optical medium. The probe experiences a modified index of refraction as it propagates through the medium and thus accumulates a phase change proportional to the intensity of the pump. The disclosed devices can be incorporated into larger components and systems for various applications such as scientific diagnostics, radar, remote sensing, wireless communications, and quantum computing that can benefit from encoding and generation of low noise, high resolution signals. Examples of the encoded information includes intrinsic noise from the optical source, or others signals of interest, such as electrical, optical, X-ray, or high-energy particle signals.

Buckley, Brandon Walter↗

Snowmass2021 Cosmic Frontier White Paper: Enabling Flagship Dark Energy Experiments to Reach their Full Potential

A new generation of powerful dark energy experiments will open new vistas for cosmology in the next decade. However, these projects cannot reach their utmost potential without data from other telescopes. This white paper focuses in particular on the compelling benefits of ground-based spectroscopic and photometric observations to complement the Vera C. Rubin Observatory, as well as smaller programs in aid of a DESI-2 experiment and CMB-S4. These additional data sets will both improve dark energy constraints from these flagship projects beyond what would possible on their own and open completely new windows into fundamental physics. For example, additional photometry and single-object spectroscopy will provide necessary follow-up information for supernova and strong lensing cosmology, while highly-multiplexed spectroscopy both from smaller facilities over wide fields and from larger facilities over narrower regions of sky will yield more accurate photometric redshift estimates for weak lensing and galaxy clustering measurements from the Rubin Observatory, provide critical spectroscopic host galaxy redshifts for supernova Hubble diagrams, provide improved understanding of limiting astrophysical systematic effects, and enable new measurements that probe the nature of gravity. A common thread is that access to complementary data from a range of telescopes/instruments would have a substantial impact on the rate of advance of dark energy science in the coming years.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Interplay between phonon downconversion efficiency, density of states at Fermi energy, and intrinsic energy resolution for microwave kinectic inductance detectors

Microwave Kinetic Inductance detectors (MKIDs) have been recognized as a powerful new tool for single photon detection. These highly multiplexed superconducting devices give timing and energy measurement for every detected photon. However, the full potential of MKID single photon spectroscopy has not been reached , the achieved energy resolution is lower than expected from first principles. Here, we study the efficiency in the phonon downconversion process following the absorption of energetic photons in MKIDs. Assuming previously published material properties, we measure an average downconversion efficiency for three TiN resonators is $\eta$=0.14. We discuss how this efficiency can impact the intrinsic energy resolution of MKID, and how any uncertainty in the unknown density of electron states at the Fermi energy directly affects the efficiency estimations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Cryogenic Readout IC with 100 KSPS in-Pixel ADC for Skipper CCD-in-CMOS Sensors

The Skipper CCD-in-CMOS Parallel Read-Out Circuit (SPROCKET) is a mixed-signal front-end design for the readout of Skipper CCD-in-CMOS image sensors. SPROCKET is fabricated in a 65 nm CMOS process and each pixel occupies a 50$\mu$m $\times$ 50$\mu$m footprint. SPROCKET is intended to be heterogeneously integrated with a Skipper-in-CMOS sensor array, such that one readout pixel is connected to a multiplexed array of nine Skipper-in-CMOS pixels to enable massively parallel readout. The front-end includes a variable gain preamplifier, a correlated double sampling circuit, and a 10-bit serial successive approximation register (SAR) ADC. The circuit achieves a sample rate of 100 ksps with 0.48 $\mathrm{e^-_{rms}}$ equivalent noise at the input to the ADC. SPROCKET achieves a maximum dynamic range of 9,000 $e^-$ at the lowest gain setting (or 900 $e^-$ at the lowest noise setting). The circuit operates at 100 Kelvin with a power consumption of 40 $\mu W$ per pixel. A SPROCKET test chip was submitted in September 2022, and test results will be presented at the conference.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Composition and method for capture and degradation of PFAS

Materials for binding per- and polyfluoroalkyl substances (PFAS) are disclosed. A fluidic device comprising the materials for detection and quantification of PFAS in a sample is disclosed. The fluidic device may be configured for multiplexed analyses. Also disclosed are methods for sorbing and remediating PFAS in a sample. The sample may be groundwater containing, or suspected of containing, one or more PFAS.

Motkuri, Radha K.↗

Optical encoder devices and systems

Devices, systems and methods for encoding information using optical components are described. Information associated with a first optical signal (e.g., an optical pump) is encoded onto the phase of a second optical signal (e.g., an optical probe) using cross phase modulation (XPM) in a non-linear optical medium. The optical signals are multiplexed together into the nonlinear optical medium. The probe experiences a modified index of refraction as it propagates through the medium and thus accumulates a phase change proportional to the intensity of the pump. The disclosed devices can be incorporated into larger components and systems for various applications such as scientific diagnostics, radar, remote sensing, wireless communications, and quantum computing that can benefit from encoding and generation of low noise, high resolution signals. Examples of the encoded information includes intrinsic noise from the optical source, or others signals of interest, such as electrical, optical, X-ray, or high-energy particle signals.

Buckley, Brandon Walter↗

Methods for generating barcoded combinatorial libraries

Provided herein are methods and composition for trackable genetic variant libraries. Further provided herein are methods and compositions for recursive engineering. Further provided herein are methods and compositions for multiplex engineering. Further provided herein are methods and compositions for enriching for editing and trackable engineered sequences and cells using nucleic acid-guided nucleases.

Gill, Ryan T.↗

Process for ultra-sensitive quantification of target analytes in complex biological systems

Antibody-free processes are disclosed that provide accurate quantification of a wide variety of low-abundance target analytes in complex samples. The processes can employ high-pressure, high-resolution chromatographic separations for analyte enrichment. Intelligent selection of target fractions may be performed via on-line Selected Reaction Monitoring (SRM) or off-line rapid screening of internal standards. Quantification may be performed on individual or multiplexed fractions. Applications include analyses of, e.g., very low abundance proteins or candidate biomarkers in plasma, cell, or tissue samples without the need for affinity-specific reagents.

Shi, Tujin↗

Will Kentucky lead the way in synthetic fuels production? A history lesson

At four times in the history of the United States, synthetic fuels have been used as the energy savior of the country, from the period immediately following the second World War to the mid 1980s when the Synthetic Fuels Corporation was unceremoniously demolished by the Reagan administration. The Center for Applied Energy Research at the University of Kentucky has been a major player in the game and the state of Kentucky has received much funding for synthetic fuels development since the 1970s. The article traces the history of developments in the field. The fate of the development has in the author's opinion been influenced by the misalignment of three 'spheres of influence' - in essence the political economy, environmental/regulatory issues, and the technological innovation process. Synthetic fuels can now become an integral part of what is called a 'multiplex energy strategy' and Kentucky again has the opportunity to build on its prior experience and embrace a new paradigm regarding how clean energy solutions based on gasification technologies can aid the USA. 4 photos.

01 COAL, LIGNITE, AND PEAT↗

Plasma Proteomic Analysis May Identify New Markers for Radiation-Induced Lung Toxicity in Patients With Non-Small-Cell Lung Cancer

Purpose: To study whether radiation induces differential changes in plasma proteomics in patients with and without radiation-induced lung toxicity (RILT) of Grade {>=}2 (RILT2). Methods and Materials: A total of 57 patients with NSCLC received radiation therapy (RT) were eligible. Twenty patients, 6 with RILT2 with tumor stage matched to 14 without RILT2, were enrolled for this analysis. Platelet-poor plasma was obtained before RT, at 2, 4, 6 weeks during RT, and 1 and 3 months after RT. Plasma proteomes were compared using a multiplexed quantitative proteomics approach involving ExacTag labeling, reverse-phase high-performance liquid chromatography and nano-LC electrospray tandem mass spectrometry. Variance components models were used to identify the differential protein expression between patients with and without RILT2. Results: More than 100 proteins were identified and quantified. After excluding proteins for which there were not at least 2 subjects with data for at least two time points, 76 proteins remained for this preliminary analysis. C4b-binding protein alpha chain, Complement C3, and Vitronectin had significantly higher expression levels in patients with RILT2 compared with patients without RILT2, based on both the data sets of RT start to 3 months post-RT (p < 0.01) and RT start to the end of RT (p < 0.01). The expression ratios of patients with RILT2 vs. without RILT2 were 1.60, 1.36, 1.46, and 1.66, 1.34, 1.46, for the above three proteins, respectively. Conclusions: This proteomic approach identified new plasma protein markers for future studies on RILT prediction.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Multi-chip photonics transceiver

A photonics transceiver is described herein, wherein the photonics transceiver exhibits improved areal bandwidth density and improved energy per bit consumption relative to conventional photonics transceivers. The photonics transceiver achieves an areal bandwidth density of at least 5 Tbps/mm2 with an energy consumption of less than 500 fJ/bit (sum of energy consumed for both a transmitted bit and a received bit). The photonics transceiver is a multi-chip module, where chips in the multi-chip module are tightly integrated with one another. The multi-chip module includes light source, photodetector, photonics, and control/logic chips. The photonics chip includes transparent conducting oxide integrated optical modulators and multiplexers and demultiplexers based on MEMS-tunable optical ring resonators.

Wood, Michael↗