Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Monitoring”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,351 records · Page 75

HDG-1 Experiment Irradiation Monitoring Data Qualification Final Report

SUMMARY The U.S. Department of Energy (DOE) Advanced Reactor Technologies (ART) Graphite Research and Development (GRD) Program is conducting a series of six experiments to quantify the effects of irradiation on nuclear-grade graphite. This report documents the qualification of irradiation monitoring data for the fifth experiment, High Dose Graphite-1 (HDG-1). Qualified monitoring data are required by the ART program to support the design and licensing of the first high-temperature reactor (HTR) nuclear plant. Data are classified as Qualified if they meet the usage requirements described in the experiment planning and quality assurance (QA) documents, Failed if they do not meet those requirements and provide no usable information, or Trend if they do not fully meet all requirements but still provide useful information subject to an assessment of how any deficiencies may affect a particular use of the data. HDG-1 irradiation began with Advanced Test Reactor (ATR) Cycle 168B on August 24, 2020, and concluded after Cycle 173C on January 27, 2025. The HDG-1 capsule was removed from the reactor core twice—during core internal change (CIC) Cycle 170A and powered axial locator mechanism (PALM) Cycle 172A—to prevent overheating of the graphite specimens during high-power PALM cycles. The capsule was therefore irradiated during a total of seven normal ATR cycles: 168B, 169A, 171A, 171B, 173A, 173B, and 173C. Irradiation monitoring data evaluated in this report include thermocouple (TC) temperature, gas flow rate, gas moisture, gas pressure, specimen load, and graphite stack displacement. Temperature. A total of 14,508,065 TC temperature records were captured. Of these, 13,901,785 (95.8%) are Qualified and 606,280 (4.2%) are Failed. The principal source of failed temperature data was the instrument failure of TC-9 (Zone 2) on June 24, 2024, and TC-10 (Zone 1) on July 5, 2024, near the end of Cycle 173A, which resulted in 595,554 Failed readings. An additional 379 missing values and 10,347 slightly negative values from TC-13 during ATR outages are also Failed. Neither TC-9 nor TC-10 was used as a temperature-control TC, and their failures did not compromise capsule condition monitoring. Correlation analysis of all 13 TCs found no evidence of virtual junction formation. Control chart analysis revealed clear downward drift of approximately 80°C for TC-6 (Zone 3) relative to other stable TCs, and possible downward drift of approximately 60°C for TC-13 relative to the Zone 5 control TC (TC-1), though TC-13 remained consistent with the Zone 2 control TC (TC-12). Gas flow. A total of 20,088,090 gas flow rate records were captured. Of these, 19,941,463 (99.3%) are Qualified and 146,627 (0.7%) are Failed due to missing values. All argon, helium, and total gas flow data were within expected ranges throughout the irradiation. Gas moisture. A total of 1,116,005 outlet gas moisture values were captured. Of these, 1,101,421 (98.7%) are Qualified and 14,584 (1.3%) are Failed, comprising 14,556 out-of-range values and 28 missing values. The out-of-range moisture values exceeded 22,000 ppmv for approximately 1 week at the beginning of Cycle 173A, when accumulated moisture evaporated after the capsule was retrieved from water storage during PALM Cycle 172A and reinserted into the east flux trap. Moisture levels returned to below 25 ppmv for the remaining three cycles, and the transient high-moisture event did not affect the integrity of specimen irradiation. Gas pressure. A total of 7,812,035 gas pressure values were captured. Of these, 6,642,048 (85.0%) are Qualified and 1,169,987 (15.0%) outlet pressure values are Failed, comprising 718,537 zero outlet pressure values due to sensor failure from Cycle 168B through Cycle 171B, 54,550 missing values, and 396,900 too-low outlet pressure values, ranging from 1.1 to 1.6 psia after sensor replacement during Cycle 173A. Load. A total of 6,696,030 load values were captured. Of these, 6,694,580 (99.98%) are Qualified and 1,450 (0.02%) are Failed due to missing values. Applied loads to the six specimen stacks were stable throughout the irradiation. Stack displacement. A total of 6,696,030 displacement values were captured. Of these, 5,713,297 (85.32%) are Qualified and 3,781 (0.06%) are Failed due to missing values. Stack displacement increased consistently throughout the irradiation, reaching approximately 3.08 in. for Channels 5 and 6 by the end of irradiation. 978,952 (14.62%) substantially elevated displacements observed for Channel 6 beginning in Cycle 171A and for Channel 5 beginning in Cycle 173A are assigned Trend status. Raising pressure. A total of 1,115,999 raising pressure values were captured. Of these, 1,115,430 (99.95%) are Qualified and 569 (0.05%) are Failed due to missing values. Ram pressure. A total of 6,696,030 ram pressure values were captured. Of these, 6,692,249 (99.95%) are Qualified and 3,484 (0.05%) are Failed due to missing values. Stack raising was perf

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Alpha-Imaging Detector System Development for Large Area Monitoring

Effective management and disposal of legacy nuclear waste are essential for ensuring safe work environments and minimizing environmental impacts. Monitoring airborne actinide contamination is particularly critical due to the high internal dose potential of alpha-emitting radionuclides. Traditional continuous air monitoring systems (CAMs) used in the industry are limited in the volume of air they can sample, potentially leading to inaccurate radiation detection over large areas. For example, in 2018, elevated levels of airborne Plutonium-239 were detected beyond the controlled areas of the Hanford Plutonium Finishing Plant, highlighting the potential risks to both plant workers and nearby residents. To address these challenges, high-efficiency particulate absorbing (HEPA) air purifiers can enhance air flow by up to 1.5 orders of magnitude, thereby increasing monitoring efficiency and providing a cost-effective solution for large-area surveillance. To quantify the activities of alpha-emitting radionuclides on HEPA filters, the Savannah River National Laboratory is developing an advanced alpha-imaging detection system. This system includes scintillating materials combined with a digital scientific camera. A significant concern in operating such a large-area airborne monitoring system is the handling of HEPA filters, which may be contaminated with radioactive particles. To mitigate these hazards, it is crucial to ensure that any contamination is securely fixed onto the filters. Efforts have been made to optimize the sensitivity of scintillator-epoxy composites and apply them to HEPA filters. These materials were characterized using fluoroscence spectroscopy. These techniques confirmed the purity of the raw materials, the dispersion of scintillators in the epoxy matrix, and the stability of their optical and structural properties post-modification. The optimal scintillator-epoxy composite was selected for use on alpha-spiked HEPA filters to evaluate the efficiency of the sprayer. HEPA filters, embedded with alpha particles collected by an air purifier deployed in an airborne radiation area, have been tested to assess detection efficiency. Future work will focus on employing multiple imaging sensors simultaneously to enhance sensitivity across different regions of the HEPA filter.

Pham, Phuong [Savannah River National Laboratory (↗

Database-Agnostic Log Analysis and Monitoring Framework

Prior to my internship, I was informed that a previous intern had built a tool to analyse MongoDB logs and look for invalid access attempts, which served as a great reference point for my project. I was initially tasked with expanding on her prototype and filling in the gaps such as integrating it with the main monitoring tool the lab uses. Eventually, the scope grew, expanding to support other databases and a growing collection of tools. I organized the framework around an observer pattern, meaning one point in the program sending updates to the rest of the framework. Every time a log was read and parsed, it was sent to be processed by the tools, using the type of event as a means to determine which tools should get a chance to act on the log. This decouples the tools from the log reader, making future updates and additions much easier. The framework processes MongoDB logs at ~135,000 entries per second and PostgreSQL logs at ~170,500 entries per second, accurately detecting anomalies such as slow queries and connections from unknown addresses. This framework serves to fill gaps in database monitoring tools currently implemented at the lab, such as tracking failed authentication for PostgreSQL and MongoDB which had very minimal or none before this framework. National labs such as Fermilab hold sensitive data and valuable computing resources, making them attractive targets. Monitoring intrusion attempts on databases is made much easier by this comprehensive monitoring suite.

Clark, Dylan [Unlisted, US, IL; Fermilab]↗

Electrical capacitance tomography to monitor unsaturated moisture ingress in cement-based materials

This paper reports the investigation of the feasibility of electrical capacitance tomography (ECT) for monitoring unsaturated moisture flow in cement-based materials. ECT is an imaging modality in which the electrical permittivity distribution within an object is reconstructed based on measured capacitances between electrodes attached on the object's surface. In a series of experiments, mortar specimens with different water-cement mass ratios (w/c) (0.25, 0.45 & 0.60) were monitored with ECT during the moisture ingress. The results demonstrate that ECT is able to image the moisture ingress within the specimens, and further, to distinguish between different moisture flow rates in mortars with different porosities resulting from differing w/c ratios. These findings suggest that ECT could provide a tool for monitoring, visualizing and quantifying the rate of moisture ingress in cement-based materials non-destructively.

36 MATERIALS SCIENCE↗

Real-time monitoring of trace noble gases using laser-induced breakdown spectroscopy—An investigation of the impact of bulk gas on plasma properties and sensitivity

The impact of Ar and He bulk gases on laser-induced breakdown spectroscopy (LIBS) real-time monitoring of trace Xe and Kr was assessed. LIBS is being developed as a monitoring tool for measuring noble gas transport in molten salt systems, in which traditional sensors may face challenges associated with radiation, corrosive materials, and/or mixed phases. The plasma temperature and electron densities of LIBS plasmas were measured in both static and various flowing Ar and He streams (0–5 L min −1 ). The use of an Ar bulk gas resulted in higher plasma temperature, greater electron densities by an order of magnitude, and extended plasma lifetime compared with when He bulk gas was used. Gas flow rate was found to have little impact on plasma temperature; however, its effect on electron density was significant, indicating the need to consider flow rate–specific models. Matrix effects on emission peaks were reported for both bulk gases. Due to these matrix effects, multivariate models were developed for Xe and Kr ranging from 0 to 700 ppm in both bulk gases. Although the predictive behavior was similar (root mean square error of prediction ranging from 11.1 to 20.6 ppm), the limits of detection were superior in He (Xe: 22.9 ppm, Kr: 30.4 ppm). Furthermore, these models were employed in demonstrative real-time tests (>1 h), which showed strong predictive precision (relative standard deviation <5 %) regardless of the bulk gas. Ultimately, this study provides a guide for the considerations required when developing gaseous LIBS models for real-time monitoring.

Gas flow effects↗

Monitoring of WEEE plastics in regards to brominated flame retardants using handheld XRF

Highlights: • Specification of an empirical factor for conversion from bromine to PBB and PBDE. • The handheld XRF device was validated for this particular application. • A very large number of over 4600 pieces of monitor housings was analysed. • The recyclable fraction mounts up to 85% for TV but only 53% of PC waste plastics. • A high percentage of pieces with bromine contents of over 50,000 ppm was obtained. - Abstract: This contribution is focused on the on-site determination of the bromine content in waste electrical and electronic equipment (WEEE), in particular waste plastics from television sets (TV) and personal computer monitors (PC) using a handheld X-ray fluorescence (XRF) device. The described approach allows the examination of samples in regards to the compliance with legal specifications for polybrominated biphenyls (PBBs) and polybrominated diphenyl ethers (PBDEs) directly after disassembling and facilitates the sorting out of plastics with high contents of brominated flame retardants (BFRs). In all, over 3000 pieces of black (TV) and 1600 pieces of grey (PC) plastic waste were analysed with handheld XRF technique for this study. Especially noticeable was the high percentage of pieces with a bromine content of over 50,000 ppm for TV (7%) and PC (39%) waste plastics. The applied method was validated by comparing the data of handheld XRF with results obtained by GC–MS. The results showed the expected and sufficiently accurate correlation between these two methods. It is shown that handheld XRF technique is an effective tool for fast monitoring of large volumes of WEEE plastics in regards to BFRs for on-site measurements.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

The upgraded data acquisition system for beam loss monitoring at the Fermilab Tevatron and Main Injector

A VME-based data acquisition system for beam-loss monitors has been developed and is in use in the Tevatron and Main Injector accelerators at the Fermilab complex. The need for enhanced beam-loss protection when the Tevatron is operating in collider-mode was the main driving force for the new design. Prior to the implementation of the present system, the beam-loss monitor system was disabled during collider operation and protection of the Tevatron magnets relied on the quench protection system. The new Beam-Loss Monitor system allows appropriate abort logic and thresholds to be set over the full set of collider operating conditions. The system also records a history of beam-loss data prior to a beam-abort event for post-abort analysis. Installation of the Main Injector system occurred in the fall of 2006 and the Tevatron system in the summer of 2007. Both systems were fully operation by the summer of 2008. In this paper we report on the overall system design, provide a description of its normal operation, and show a number of examples of its use in both the Main Injector and Tevatron.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The development of remote wireless radiation dose monitoring system

Internet of things (IoT) technology has recently shown a large flow of IT trends in human life. In particular, our lives are now becoming integrated with a lot of items around the 'smart-phone' with IoT, including Bluetooth, Near Field Communication (NFC), Beacons, WiFi, and Global Positioning System (GPS). Our project focuses on the interconnection of radiation dosimetry and IoT technology. The radiation workers at a nuclear facility should hold personal dosimeters such as a Thermo-Luminescence Dosimeter (TLD), an Optically Stimulated Luminescence Dosimeter (OSL), pocket ionization chamber dosimeters, an Electronic Personal Dosimeter (EPD), or an alarm dosimeter on their body. Some of them have functions that generate audible or visible alarms to radiation workers in a real working area. However, such devices used in radiation fields these days have no functions for communicating with other areas or the responsible personnel in real time. In particular, when conducting a particular task in a high dose area, or a number of repair works within a radiation field, radiation dose monitoring is important for the health of the workers and the work efficiency. Our project aims at the development of a remote wireless radiation dose monitoring system (RWRD) that can be used to monitor the radiation dose in a nuclear facility for radiation workers and a radiation protection program In this project, a radiation dosimeter is the detection device for personal radiation dose, a smart phone is the mobile wireless communication tool, and, Beacon is the wireless starter for the detection, communication, and position of the worker using BLE (Bluetooth Low Energy). In this report, we report the design of the RWRD and a demonstration case in a real radiation field. (authors)

61 RADIATION PROTECTION AND DOSIMETRY↗

An approach to online network monitoring using clustered patterns

Network traffic monitoring is a core element in network operations and management for various purposes such as anomaly detection, change detection, and fault/failure detection. In this study, we introduce a new approach to online monitoring using a pattern-based representation of the network traffic. Unlike the past online techniques limited to a single variable to summarize (e.g., sketch), the focus of this study is on capturing the network state from the multivariate attributes under consideration. To this end, we employ clustering with its benefit of the aggregation of multidimensional variables. The clustered result represents the state of the network with regard to the monitored variables, which can also be compared with the previously observed patterns visually and quantitatively. Finally, we demonstrate the proposed method with two popular use cases, one for estimating state changes and the other for identifying anomalous states, to confirm its feasibility.

97 MATHEMATICS AND COMPUTING↗

Resilient Monitoring Systems: Architecture, Design, and Application to Boiler/Turbine Plant

Resilient monitoring systems, considered in this paper, are sensor networks that degrade gracefully under malicious attacks on their sensors, causing them to project misleading information. The goal of this work is to design, analyze, and evaluate the performance of a resilient monitoring system intended to monitor plant conditions (normal or anomalous). The architecture developed consists of four layers: data quality assessment, process variable assessment, plant condition assessment, and sensor network adaptation. Each of these layers is analyzed by either analytical or numerical tools. The performance of the overall system is evaluated using a simplified boiler/turbine plant. The measure of resiliency is quantified using Kullback-Leibler divergence, and is shown to be sufficiently high in all scenarios considered.

97 MATHEMATICS AND COMPUTING↗

Remote Monitoring and Diagnostics of Pitch-Bearing Defects in an MW-Scale Wind Turbine Using Pitch Symmetrical-Component Analysis

Recently, multiple wind turbine failure databases have reviewed that the pitch system is one of the subassemblies with the highest failure rates and largest contributors to the overall downtime. Therefore, there has been an increasing interest to provide remote health monitoring for wind turbine pitch system. While most of the research articles are discussing pitch actuation system (hydraulic or electric actuator) faults only, there is very limited research on pitch-bearing-defect detection. This article provides a remote and hardware-free solution to monitor multiaxis pitch-bearing health condition called pitch symmetrical-component analysis. It leverages readily available low-resolution (100 Hz) electrical measurements, mechanical measurements, and control signals from the existing pitch control platform, and innovatively applies symmetrical-component analysis in multiphase ac system to multiaxis pitch control system and introduces multiaxis pitch-bearing degradation trending curves. This hardware-free solution can be directly applied to the existing wind turbines and successfully give the wind farm operator an early warning before multiaxis pitch bearing fails. It has been proved to be accurate, low cost, and has minimum impacts on turbine normal operation, and has been validated by field data from several North America MW-scale wind farms. This approach turns out to be the first hardware-free (no additional hardware needed) method to remotely monitor and diagnose multiaxis wind turbine pitch-bearing condition.

17 WIND ENERGY↗

Evaluation of Enhanced Risk Monitors for Use on Advanced Reactors

This study provides an overview of the methodology for integrating time-dependent failure probabilities into nuclear power reactor risk monitors. This prototypic enhanced risk monitor (ERM) methodology was evaluated using a hypothetical probabilistic risk assessment (PRA) model, generated using a simplified design of a liquid-metal-cooled advanced reactor (AR). Component failure data from industry compilation of failures of components similar to those in the simplified AR model were used to initialize the PRA model. Core damage frequency (CDF) over time were computed and analyzed. In addition, a study on alternative risk metrics for ARs was conducted. Risk metrics that quantify the normalized cost of repairs, replacements, or other operations and management (O&M) actions were defined and used, along with an economic model, to compute the likely economic risk of future actions such as deferred maintenance based on the anticipated change in CDF due to current component condition and future anticipated degradation. Such integration of conventional-risk metrics with alternate-risk metrics provides a convenient mechanism for assessing the impact of O&M decisions on safety and economics of the plant. It is expected that, when integrated with supervisory control algorithms, such integrated-risk monitors will provide a mechanism for real-time control decision-making that ensure safety margins are maintained while operating the plant in an economically viable manner.

ECA↗

A method for online verification of adapted fields using an independent dose monitor

Purpose: Clinical implementation of online adaptive radiotherapy requires generation of modified fields and a method of dosimetric verification in a short time. We present a method of treatment field modification to account for patient setup error, and an online method of verification using an independent monitoring system.Methods: The fields are modified by translating each multileaf collimator (MLC) defined aperture in the direction of the patient setup error, and magnifying to account for distance variation to the marked isocentre. A modified version of a previously reported online beam monitoring system, the integral quality monitoring (IQM) system, was investigated for validation of adapted fields. The system consists of a large area ion-chamber with a spatial gradient in electrode separation to provide a spatially sensitive signal for each beam segment, mounted below the MLC, and a calculation algorithm to predict the signal. IMRT plans of ten prostate patients have been modified in response to six randomly chosen setup errors in three orthogonal directions.Results: A total of approximately 49 beams for the modified fields were verified by the IQM system, of which 97% of measured IQM signal agree with the predicted value to within 2%.Conclusions: The modified IQM system was found to be suitable for online verification of adapted treatment fields.

61 RADIATION PROTECTION AND DOSIMETRY↗

Preliminary results on the feasibility of using ultrasound to monitor intrafractional motion during radiation therapy for pancreatic cancer

Purpose: Substantial intrafraction organ motion during radiation therapy (RT) for pancreatic cancer is well recognized as a major limiting factor for accurate delivery of RT. The aim of this work is to determine the feasibility of monitoring the intrafractional motion of the pancreas or surrounding structures using ultrasound for RT delivery. Methods: Transabdominal ultrasound (TAUS) and 4DCT data were acquired on ten pancreatic cancer patients during radiation therapy process in a prospective study. In addition, TAUS and MRI were collected for five healthy volunteers. The portal vein (PV) and the head of the pancreas (HP) along with other structures were contoured on these images. Volume changes, distance between the HP and PV, and motion difference between the HP and PV were measured to examine whether PV can be used as a motion surrogate for HP. TAUS images were acquired and processed using a research version of the Clarity autoscan ultrasound system (CAUS). Motion monitoring was performed with the ultrasound probe mounted on an arm fixed to the couch. Video segments of the monitoring sessions were captured. Results: On TAUS, PV is better visualized than HP. The measured mean volume deviation for all patients for the HP and PV was 1.4 and 0.6 ml, respectively. The distance between the HP and PV was close to a constant with 0.22 mm mean deviation throughout the ten breathing phases. The mean of the absolute motion difference for all patients was 1.7 ± 0.8 mm in LR, 1.5 ± 0.5 mm in AP, and 2.3 ± 0.7 mm in SI, suggesting that the PV is a good surrogate for HP motion estimation. By using this surrogate, the HP motion tracking using TAUS was demonstrated. Conclusions: Large intrafractional organ motion due to respiratory and/or bowel motion is a limiting factor in administering curative radiation doses to pancreatic tumors. The authors investigate the use of real-time ultrasound to track pancreas motion. Due to the poor visibility of the pancreas head on an ultrasound image, the portal vein is identified as a surrogate. The authors have demonstrated the feasibility of tracking HP motion through the localization of the PV using TAUS. This will potentially allow real-time tracking of intrafractional motion to justify small PTV-margins and to account for unusual motions, thus, improving normal tissue sparing.

60 APPLIED LIFE SCIENCES↗

Beyond Arms-Control Monitoring

Expanded monitoring of the environment, everywhere and at all times, can advance arms control around the world, enhancing transparency among nations. In particular, improved characterization of the atmosphere now offers powerful opportunities for global monitoring, with multiple societal benefits. It may be useful to think of environmental monitoring as a long-term objective of arms-control verification.

arms-control monitoring↗

Idaho National Laboratory (INL) Site Greenhouse Gas (GHG) Monitoring Plan - 40 CFR 98 (Revision 2)

The purpose of this Greenhouse Gas (GHG) Monitoring Plan is to meet the monitoring plan requirements of Title 40 of the Code of Federal Regulations Part 98.3(g)(5). This GHG Monitoring Plan identifies procedures and methodologies used at the Idaho National Laboratory Site (INL Site) to collect data used for GHG emissions calculations and reporting requirements from stationary combustion and other regulated sources in accordance with 40 CFR 98, Subparts A and other applicable subparts. INL Site Contractors determined subpart applicability through the use of a checklist (Appendix A). Each facility/contractor reviews operations to determine which subparts are applicable and the results are compiled to determine which subparts are applicable to the INL Site. This plan is applicable to the 40 CFR 98-regulated activities managed by the INL Site contractors: Idaho National Laboratory (INL), Idaho Cleanup Project (ICP), Advanced Mixed Waste Treatment Project (AMWTP), and Naval Reactors Facilities (NRF).

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

2011 Radiological Monitoring Results Associated with the Advanced Test Reactor Complex Cold Waste Pond

This report summarizes radiological monitoring performed of the Idaho National Laboratory Site's Advanced Test Reactor Complex Cold Waste wastewater prior to discharge into the Cold Waste Pond and of specific groundwater monitoring wells associated with the Industrial Wastewater Reuse Permit (LA-000161-01, Modification B). All radiological monitoring is performed to fulfill Department of Energy requirements under the Atomic Energy Act.

2011↗

Radiological Monitoring Results For Groundwater Samples Associated with the Industrial Wastewater Reuse Permit for the Materials and Fuels Complex Industrial Waste Ditch and Pond: November 1, 2010-October 31, 2011

This report summarizes radiological monitoring performed on samples from specific groundwater monitoring wells associated with the Industrial Wastewater Reuse Permit for the Materials and Fuels Complex Industrial Waste Ditch and Industrial Waste Pond (No.LA-000160-01). The radiological monitoring was performed to fulfill Department of Energy requirements under the Atomic Energy Act.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗