Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Measurement error”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,351 records · Page 75

A Comparison of Land Surface Model Soil Hydraulic Properties Estimated by Inverse Modeling and Pedotransfer Functions

Soil hydraulic properties (SHPs) regulate the movement of water in the soil. This in turn plays an important role in the water and energy cycles at the land surface. At present, SHPS are commonly defined by a simple pedotransfer function from soil texture class, but SHPs vary more within a texture class than between classes. To examine the impact of using soil texture class to predict SHPS, we run the Noah land surface model for a wide variety of measured SHPs. We find that across a range of vegetation cover (5 - 80% cover) and climates (250 - 900 mm mean annual precipitation), soil texture class only explains 5% of the variance expected from the real distribution of SHPs. We then show that modifying SHPs can drastically improve model performance. We compare two methods of estimating SHPs: (1) inverse method, and (2) soil texture class. Compared to texture class, inverse modeling reduces errors between measured and modeled latent heat flux from 88 to 28 w/m(exp 2). Additionally we find that with increasing vegetation cover the importance of SHPs decreases and that the van Genuchten m parameter becomes less important, while the saturated conductivity becomes more important.

Gutmann, Ethan D.↗

Overview of oxygen opacity experiments at the National Ignition Facility and investigation of potential systematic errors

Experiments to measure oxygen opacity at stellar interior conditions have been performed at the National Ignition Facility in a Discovery Science campaign. These experiments utilize the Opacity-on-NIF platform with a sample comprised of O, Mg, and Si. The spectral data from the Opacity Spectrometer cover the 1000–2000 eV photon energy range showing bound-free continuum absorption from O and line absorption from Mg and Si. DANTE and the Gated X-ray Detector are employed to measure the sample plasma’s temperature and density, respectively. Initial data show lower transmission than expected by theoretical models, raising questions of whether potential background or data uniformity concerns could produce systematic errors in the inferred transmission. Here, we investigate three concerns thought to be important for the oxygen opacity data, including instrumental scattered background, sample self-emission non-uniformity, and backlight continuum non-uniformity. Additionally, we show the effect of a recently developed method to account for 2nd order crystal reflection. The total effect of these concerns on one experiment is found to be small compared to the observed difference between the inferred transmission and a model calculation at the inferred temperature and density. Thus, we conclude that these potential sources of systematic error cannot account for the observed difference, increasing the likelihood of a real effect due to the high temperature and density conditions. However, because this is only a single experiment, we cannot make a firm conclusion. More experiments measuring the opacity and necessary calibrations are needed to assess the reproducibility and uncertainty of this result.

79 ASTRONOMY AND ASTROPHYSICS↗

Direct Randomized Benchmarking for Multiqubit Devices

Benchmarking methods that can be adapted to multiqubit systems are essential for assessing the overall or “holistic” performance of nascent quantum processors. The current industry standard is Clifford randomized benchmarking (RB), which measures a single error rate that quantifies overall performance. But, scaling Clifford RB to many qubits is surprisingly hard. It has only been performed on one, two, and three qubits as of this writing. This reflects a fundamental inefficiency in Clifford RB: the n-qubit Clifford gates at its core have to be compiled into large circuits over the one- and two-qubit gates native to a device. As n grows, the quality of these Clifford gates quickly degrades, making Clifford RB impractical at relatively low n. In this Letter, we propose a direct RB protocol that mostly avoids compiling. Instead, it uses random circuits over the native gates in a device, which are seeded by an initial layer of Clifford-like randomization. We demonstrate this protocol experimentally on two to five qubits using the publicly available ibmqx5. We believe this to be the greatest number of qubits holistically benchmarked, and this was achieved on a freely available device without any special tuning up. Our protocol retains the simplicity and convenient properties of Clifford RB: it estimates an error rate from an exponential decay. But, it can be extended to processors with more qubits—we present simulations on 10+ qubits—and it reports a more directly informative and flexible error rate than the one reported by Clifford RB. Here, we show how to use this flexibility to measure separate error rates for distinct sets of gates, and we use this method to estimate the average error rate of a set of cnot gates.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

SU-D-210-07: The Dependence On Acoustic Velocity of Medium On the Needle Template and Electronic Grid Alignment in Ultrasound QA for Prostate Brachytherapy

Purpose: To analyze the impact on acoustic velocity (AV) of two different media (water and milk) using the needle template/electronic grid alignment test. Water, easily available, makes a good material to test the alignment of the template and grid although water’s AV (1498 m/s at 25°C) is significantly different from tissue (1540 m/s). Milk, with an AV much closer (1548 m/s) to prostate tissue, may be a good substitute for water in ultrasound quality assurance testing. Methods: Tests were performed using a Hitachi ultrasound unit with a mechanical arrangement designed to position needles parallel to the transducer. In this work, two materials – distilled water and homogenized whole milk (AVs of 1498 and 1548 m/s at 25°C) were used in a phantom to test ultrasound needle/grid alignment. The images were obtained with both materials and analyzed for their placement accuracy. Results: The needle template/electronic grid alignment tests showed displacement errors between measured and calculated values. The measurements showed displacements of 2.3mm (water) and 0.4mm (milk), and 1.6mm (water) and 0.3mm (milk) at depths of 7cm and 5cm respectively from true needle positions. The calculated results showed a displacement of 2.36 mm (water); 0.435mm (milk), and 1.66mm (water) and 0.31mm (milk) at a depth of 7cm and 5cm respectively. The displacements in the X and Y directions were also calculated. At depths of 7cm and 5cm, the (ΔX,ΔY) displacements in water were (0.829mm, 2.21mm) and (0.273mm, 1.634mm) and for milk were (0.15mm, 0.44mm) and (0.05mm, 0.302mm) respectively. Conclusion: The measured and calculated values were in good agreement for all tests. They show that milk provides superior results when performing needle template and electronic grid alignment tests for ultrasound units used in prostate brachytherapy.

60 APPLIED LIFE SCIENCES↗

An indirect approach to optimize the reaction rates of thermal NO formation for diesel engines

With stringent emission regulations, it has become more important for modern diesel engine manufacturers to accurately predict engine-out nitrogen oxide (NO x ) emissions across a wide range of operating conditions. Thermal NO is the major source of engine-out NO x in modern diesel engines. For thermal NO formation, several earlier studies have recommended the forward and reverse reaction rate coefficients of the rate-limiting reaction (O + N 2 ⇌ NO + N). However, due to deficiencies in sub-models and inadequacies of reduced chemical mechanisms to represent diesel combustion, these recommended values more often than not need to be adjusted in reduced order combustion models to accurately predict engine-out NO x . Hence, in this work a systematic and computationally efficient approach has been proposed to streamline the process of determining the optimum reaction rate coefficients. Here, to develop the optimization approach, four different production diesel engines with different operating conditions in terms of speed, load, and exhaust-gas recirculation have been considered. Numerical simulations have been performed using a detailed zero-dimensional velocity-composition-frequency transported probability density function (0D-VCF-tPDF) model that uses hundreds of notional particles to capture in-cylinder stratification. Four different combinations of hydrocarbon and NO x chemical mechanisms were used to represent chemistry. It was found that for the rate-limiting reaction, the pre-exponent factors (A f1 , A r1 ) and activation energies (E A,f1 , E A,r1 ) of the forward and reverse reaction rates follow a linear band in A f1 - E A,f1 and A r1 - E A,r1 space where predicted engine-out NO x match the measured values closely. By encompassing such bands from different engines and considering constraints on activation energies, a reduced search domain of pre-exponent factors and activation energies was constructed that is expected to be applicable to any diesel engine. Eventually, computationally efficient three-line and one-line search approaches were proposed to determine the optimum values of the pre-exponent factors and activation energies that led to a minimum error between measured and predicted engine-out NO x . Finally, these three-line and one-line NO x optimization approaches were applied to a fifth production diesel engine for which the 0D-VCF-tPDF model showed a very good predictive performance in terms of predicting peak pressure, 50% burn rate, and engine-out NO x when compared to measured and 3D-CFD values.

33 ADVANCED PROPULSION SYSTEMS↗

Applications of parameter estimation in the study of spinning airplanes

Spinning airplanes offer challenges to estimating dynamic parameters because of the nonlinear nature of the dynamics. In this paper, parameter estimation techniques are applied to spin flight test data for estimating the error in measuring post-stall angles of attack, deriving Euler angles from angular velocity data, and estimating nonlinear aerodynamic characteristics. The value of the scale factor for post-stall angles of attack agrees closely with that obtained from special wind-tunnel tests. The independently derived Euler angles are seen to be valid in spite of steep pitch angles. Estimates of flight derived nonlinear aerodynamic parameters are evaluated in terms of the expected fit error.

W Taylor, L., Jr.↗

The Mass–Concentration Relation and the Stellar-to-halo Mass Ratio in the CFHT Stripe 82 Survey

We present a new measurement of the mass–concentration relation and the stellar-to-halo mass ratio over the halo-mass range 5 × 10{sup 12} to 2 × 10{sup 14} M {sub ⊙}. To achieve this, we use weak lensing measurements from the Canada–France–Hawaii Telescope Stripe 82 Survey (CS82), combined with the central galaxies from the redMaPPer cluster catalog and the LOWZ/CMASS galaxy sample of the Sloan Digital Sky Survey-III Baryon Oscillation Spectroscopic Survey Tenth Data Release. The stacked lensing signals around these samples are modeled as a sum of contributions from the central galaxy, its dark matter halo, and the neighboring halos, as well as a term for possible centering errors. We measure the mass–concentration relation: c{sub 200c}(M)=A(((M{sub 200c})/(M{sub 0}))){sup B} with A = 5.24 ± 1.24, B = −0.13 ± 0.10 for 0.2 < z < 0.4, and A = 6.61 ± 0.75, B = −0.15 ± 0.05 for 0.4 < z < 0.6. These amplitudes and slopes are completely consistent with predictions from recent simulations. We also measure the stellar-to-halo mass ratio for our samples, and find results consistent with previous measurements from lensing and other techniques.

79 ASTRONOMY AND ASTROPHYSICS↗

Measuring interstellar grains from the haloes of binary X-ray sources

Coherent forward scattering of X-rays by interstellar grains creates a halo around the X-ray image of a compact source. The fractional halo brightness at 2 keV is typically of order 10% moderately reddened galactic sources. The angular brightness distribution of the halo, which extends over several arcminutes, indicates the size distribution of the grains, and the spectrum of the halo indicates the composition of the grains. The halo will persist for several hours after the point source vanishes during an eclipse of a binary source; this provides a way to avoid systematic errors in measuring halo brightness due to an extended point response function of the X-ray telescope. Indeed, it is possilbe to infer the size distribution and composition of the grains without an imaging X-ray telescope by observing the time-dependence of the halo spectrum during eclipse.

Xu, Y.↗

Error-correcting Bacon-Shor code with continuous measurement of noncommuting operators

We analyze the continuous operation of the nine-qubit error correcting Bacon-Shor code with all noncommuting gauge operators measured at the same time. The error syndromes are continuously monitored using cross-correlations of sets of three measurement signals. We calculate the logical error rates due to $X$, $Y$ and $Z$ errors in the physical qubits and compare the continuous implementation with the discrete operation of the code. We find that both modes of operation exhibit similar performances when the measurement strength from continuous measurements is sufficiently strong. Here, we also estimate the value of the crossover error rate of the physical qubits, below which continuous error correction gives smaller logical error rates. Continuous operation has the advantage of passive monitoring of errors and avoids the need for additional circuits involving ancilla qubits.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

SU-E-J-177: A Computational Approach for Determination of Anisotropic PTV Margins Based On Statistical Shape Analysis for Prostate Cancer Radiotherapy

Purpose: Our aim of this study was to propose a computational approach for determination of anisotropic planning target volume (PTV) margins based on statistical shape analysis with taking into account time variations of clinical target volume (CTV) shapes for the prostate cancer radiation treatment planning (RTP). Methods: Systematic and random setup errors were measured using orthogonal projection and cone beam computed tomography (CBCT) images for data of 20 patients, who underwent the intensity modulated radiation therapy for prostate cancer. The low-risk, intermediate-risk, and high-risk CTVs were defined as only a prostate, a prostate plus proximal 1-cm seminal vesicles, and a prostate plus proximal 2-cm seminal vesicles, respectively. All CTV regions were registered with a reference CTV region with a median volume to remove the effect of the setup errors, and converted to a point distribution models. The systematic and random errors for translations of CTV regions were automatically evaluated by analyzing the movements of centroids of CTV regions. The random and systematic errors for shape variations of CTV regions were obtained from covariance matrices based on point distributions for the CTV contours on CBCT images of 72 fractions of 10 patients. Anisotropic PTV margins for 6 directions (right, left, anterior, posterior, superior and inferior) were derived by using Yoda’s PTV margin model. Results: PTV margins with and without shape variations were 5.75 to 8.03 mm and 5.23 to 7.67 mm for low-risk group, 5.87 to 8.33 mm and 5.23 to 7.67 mm for intermediate-risk group, and 5.88 to 8.25 mm and 5.29 to 7.82 mm for highrisk group, respectively. Conclusion: The proposed computational approach could be feasible for determination of the anisotropic PTV margins with taking into account CTV shape variations for the RTP.

60 APPLIED LIFE SCIENCES↗

Solar concentrator panel and gore testing in the JPL 25-foot space simulator

The optical imaging characteristics of parabolic solar concentrator panels (or gores) have been measured using the optical beam of the JPL 25-foot space simulator. The simulator optical beam has been characterized, and the virtual source position and size have been determined. These data were used to define the optical test geometry. The point source image size and focal length have been determined for several panels. A flux distribution of a typical solar concentrator has been estimated from these data. Aperture photographs of the panels were used to determine the magnitude and characteristics of the reflecting surface errors. This measurement technique has proven to be highly successful at determining the optical characteristics of solar concentrator panels.

Dennison, E. W.↗

In situ measurements of BrO during AASE II

BrO measured from the NASA ER-2 during Airborne Arctic Stratospheric Expedition (AASE) II exhibited a mean value (for 20-minute averages) of 5.4 +/- 0.3 pptv, with a standard deviation of 3.1 pptv. Ratios of BrO to available inorganic bromine (Br(sub y)) show only slight increases in polar regions relative to midlatitudes. A comparison between observed latitudinal and diurnal variations of this same ratio and that calculated by photochemical models shows reasonable agreement in behavior, but significant discrepancies in magnitude. It is unclear whether this difference is due to errors in measurements, models or both.

Avallone, L. M.↗

Design and analysis of a torsion braid pendulum displacement transducer

The dynamic properties at various temperatures of braids impregnated with polymer can be measured by using the braid as the suspension of a torsion pendulum. This report describes the electronic and mechanical design of a torsional braid pendulum displacement transducer which is an advance in the state of the art. The transducer uses a unique optical design consisting of refracting quartz windows used in conjunction with a differential photocell to produce a null signal. The release mechanism for initiating free torsional oscillation of the pendulum has also been improved. Analysis of the precision and accuracy of the transducer indicated that the maximum relative error in measuring torsional amplitude was approximately 0. A serious problem inherent in all instruments which use a torsional suspension was analyzed: misalignment of the physical and torsional axes of the torsional member which results in modulation of the amplitude of the free oscillation.

Rind, E.↗

Stereo depth distortions in teleoperation

In teleoperation, a typical application of stereo vision is to view a work space located short distances (1 to 3m) in front of the cameras. The work presented here treats converged camera placement and studies the effects of intercamera distance, camera-to-object viewing distance, and focal length of the camera lenses on both stereo depth resolution and stereo depth distortion. While viewing the fronto-parallel plane 1.4 m in front of the cameras, depth errors are measured on the order of 2cm. A geometric analysis was made of the distortion of the fronto-parallel plane of divergence for stereo TV viewing. The results of the analysis were then verified experimentally. The objective was to determine the optimal camera configuration which gave high stereo depth resolution while minimizing stereo depth distortion. It is found that for converged cameras at a fixed camera-to-object viewing distance, larger intercamera distances allow higher depth resolutions, but cause greater depth distortions. Thus with larger intercamera distances, operators will make greater depth errors (because of the greater distortions), but will be more certain that they are not errors (because of the higher resolution).

Diner, Daniel B.↗

Individual Load Model Parameter Estimation in Distribution Systems Using Load Switching Events

There currently exists a mature literature on modeling the aggregate load of a distribution feeder by making use of measurements at its feeder-head at substation. The primary application of such feeder-aggregated load models is in sub-transmission or transmission system analysis. However, there is a growing need in practice also to model each individual load across the feeder. If available, such individual load models have applications in power distribution system analysis, e.g., to better integrate distributed energy resources or to improve power quality and reliability. Motivated by this observation, in this paper, we propose a new method for individual load modeling in power distribution systems. It works by using the measurements only at the feeder-head. It takes an innovative approach to analyzing the load switching events across the distribution feeder itself, instead of or in addition to relying on upstream voltage events that are commonly used in feeder-aggregated load modeling. By tracking the downstream load switching events, the proposed method can make a robust estimation of the ZIP load model parameters for all individual loads. The proposed method is examined on small illustrative test-feeders as well as the IEEE 33-bus test system under various operating scenarios. The adverse impact of errors in measurements and system parameters are also investigated on the performance of the developed load modeling method.

24 POWER TRANSMISSION AND DISTRIBUTION↗

How to avoid multiple scattering in strongly scattering SANS and USANS samples

Small Angle Neutron Scattering (SANS) and Ultra Small Angle Neutron Scattering (USANS) are the only available experimental techniques to provide seamless non-destructive measurements of the geometry of the accessible and inaccessible pore structure of rocks from sub-nanopore size to the scale of macropores. They have therefore become the measurement of choice for tight reservoir rocks such as organic rich shales. A simplifying assumption in the analysis is, however, that during the path of neutrons through the sample each neutron is only scattered once. Shales are samples with a high scattering power and Multiple Scattering (MS) may occur which requires special modelling for deconvolution of the results. The approach to avoid MS is to simply reduce the sample thickness to <0.15–0.5 mm. Here, in this work, we present a systematic method on wavelength selection and preparation of samples to optimise extraction of microstructural data and minimise parasitic errors. Experimentally measured SAS transmission (TSAS) values are used as a practical criterion for estimation of the extent of MS. Generous beamtime allocations allowed robust testing revealing that sample thicknesses can be twice as thick as predicted using the standard protocol. Analysing thicker samples is particularly beneficial for statistically relevant characterisation of heterogeneous samples making the new protocol the method of choice for such samples.

(U)SANS↗

Sensitivity analysis for airborne and spaceborne DIAL measurements of H2O profiles

Random and systematic error sourses are presently analyzed for atmospheric H2O detection in the vicinity of the 720 nm absorption bands with Differential Absorption Lidar (DIAL). Attention is given to the random errors due to undertainties in the measurement of the lidar signal and noise that are associated with the background and detector dark currents. Systematic errors are related to Doppler broadening due to backscattering from air molecules, the pressure shift of H2O lines, laser line distortions, spectral impurities, and laser tuning errors. Global measurements of H2O profiles from spaceborne DIAL systems are achievable with 200 m vertical x 10 km horizontal during nighttime, and 250 m vertical x 20 km horizontal during daytime.

Ismail, Syed↗

Stochastic Error Cancellation in Analog Quantum Simulation

Analog quantum simulation is a promising path towards solving classically intractable problems in many-body physics on near-term quantum devices. However, the presence of noise limits the size of the system and the length of time that can be simulated. In our work, we consider an error model in which the actual Hamiltonian of the simulator differs from the target Hamiltonian we want to simulate by small local perturbations, which are assumed to be random and unbiased. We analyze the error accumulated in observables in this setting and show that, due to stochastic error cancellation, with high probability the error scales as the square root of the number of qubits instead of linearly. We explore the concentration phenomenon of this error as well as its implications for local observables in the thermodynamic limit. Moreover, we show that stochastic error cancellation also manifests in the fidelity between the target state at the end of time-evolution and the actual state we obtain in the presence of noise. This indicates that, to reach a certain fidelity, more noise can be tolerated than implied by the worst-case bound if the noise comes from many statistically independent sources.

Analog quantum simulation↗