Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Image Segmentation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,351 records · Page 75

SU-E-QI-16: Reproducibility of Computed Tomography Quantitative Structural Features Using the FDA Thoracic Phantom Image Database

Purpose: To assess the reproducibility of quantitative structural features using images from the computed tomography thoracic FDA phantom database under different scanning conditions. Methods: Development of quantitative image features to describe lesion shape and size, beyond conventional RECIST measures, is an evolving area of research in need of benchmarking standards. Gavrielides et al. (2010) scanned a FDA-developed thoracic phantom with nodules of various Hounsfield units (HU) values, shapes and sizes close to vascular structures using several scanners and varying scanning conditions/parameters; these images are in the public domain. We tested six structural features, namely, Convexity, Perimeter, Major Axis, Minor Axis, Extent Mean and Eccentricity, to characterize lung nodules. Convexity measures lesion irregularity referenced to a convex surface. Previously, we showed it to have prognostic value in lung adenocarcinoma. The above metrics and RECIST measures were evaluated on three spiculated (8mm/-300HU, 12mm/+30HU and 15mm/+30HU) and two non-spiculated (8mm/+100HU and 10mm/+100HU) nodules (from layout 2) imaged at three different mAs values: 25, 100 and 200 mAs; on a Phillips scanner (16-slice Mx8000-IDT; 3mm slice thickness). The nodules were segmented semi-automatically using a commercial software tool; the same HU range was used for all nodules. Results: Analysis showed convexity having the lowest maximum coefficient of variation (MCV): 1.1% and 0.6% for spiculated and non-spiculated nodules, respectively, much lower compared to RECIST Major and Minor axes whose MCV were 10.1% and 13.4% for spiculated, and 1.9% and 2.3% for non-spiculated nodules, respectively, across the various mAs. MCVs were consistently larger for speculated nodules. In general, the dependence of structural features on mAs (noise) was low. Conclusion: The FDA phantom CT database may be used for benchmarking of structural features for various scanners and scanning conditions; we used only a small fraction of available data. Our feature convexity outperformed other structural features including RECIST measures.

60 APPLIED LIFE SCIENCES↗

Magnetic resonance cholangiopancreatography using optimized integrated combination with parallel imaging and compressed sensing technique

Purpose: To assess the combined parallel imaging (PI) and optimized integrated compressed sensing technique (prototype Compressed SENSE) for magnetic resonance cholangiopancreatography (MRCP) compared with conventional MRCP. Methods: This prospective study was approved by our Institutional Review Board, and all patients provided written informed consent. A total of 56 consecutive patients (27 men and 29 women; mean age 67.2 years) underwent breath-hold three-dimensional (3D) MRCP with PI alone (BH-MRCP; acquisition time, 23 s), respiratory-triggered 3D MRCP with PI alone (RT-MRCP; 201 s) and respiratory-triggered 3D MRCP with Compressed SENSE (RT-MRCPcs; 45 s). Relative duct-to-periductal contrast ratios (RCs) of the pancreaticobiliary ducts were calculated for quantitative image analyses. Two radiologists graded the visibility of the pancreaticobiliary ducts, pancreatic cystic lesion, motion artifact, and overall image quality using a five-point rating scale for qualitative image analyses. Theses qualitative and quantitative measurements were then compared among the three sequences. Results: RCs of the common bile duct, right hepatic duct (RHD), left hepatic duct (LHD), and main pancreatic duct at the pancreatic head, body, and tail segments, were significantly higher RT-MRCP, followed by RT-MRCPcs and BH-MRCP (P < 0.001). The visibility of the peripheral RHD and LHD was slightly better in RT-MRCP than in RT-MRCPcs and BH-MRCP (P < 0.001). The visibility of other pancreaticobiliary ducts, pancreatic cystic lesion, motion artifact, and overall image quality were almost comparable among three sequences. Conclusion: The acquisition time was markedly reduced in RT-MRCPcs compared with conventional RT-MRCP while there were significant differences in both quantitative and qualitative analyses, the differences were small enough that the reduced acquisition time makes up for it.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Vision 20/20: Magnetic resonance imaging-guided attenuation correction in PET/MRI: Challenges, solutions, and opportunities

Attenuation correction is an essential component of the long chain of data correction techniques required to achieve the full potential of quantitative positron emission tomography (PET) imaging. The development of combined PET/magnetic resonance imaging (MRI) systems mandated the widespread interest in developing novel strategies for deriving accurate attenuation maps with the aim to improve the quantitative accuracy of these emerging hybrid imaging systems. The attenuation map in PET/MRI should ideally be derived from anatomical MR images; however, MRI intensities reflect proton density and relaxation time properties of biological tissues rather than their electron density and photon attenuation properties. Therefore, in contrast to PET/computed tomography, there is a lack of standardized global mapping between the intensities of MRI signal and linear attenuation coefficients at 511 keV. Moreover, in standard MRI sequences, bones and lung tissues do not produce measurable signals owing to their low proton density and short transverse relaxation times. MR images are also inevitably subject to artifacts that degrade their quality, thus compromising their applicability for the task of attenuation correction in PET/MRI. MRI-guided attenuation correction strategies can be classified in three broad categories: (i) segmentation-based approaches, (ii) atlas-registration and machine learning methods, and (iii) emission/transmission-based approaches. This paper summarizes past and current state-of-the-art developments and latest advances in PET/MRI attenuation correction. The advantages and drawbacks of each approach for addressing the challenges of MR-based attenuation correction are comprehensively described. The opportunities brought by both MRI and PET imaging modalities for deriving accurate attenuation maps and improving PET quantification will be elaborated. Future prospects and potential clinical applications of these techniques and their integration in commercial systems will also be discussed.

61 RADIATION PROTECTION AND DOSIMETRY↗

Automated temporal tracking and segmentation of lymphoma on serial CT examinations

Purpose: It is challenging to reproducibly measure and compare cancer lesions on numerous follow-up studies; the process is time-consuming and error-prone. In this paper, we show a method to automatically and reproducibly identify and segment abnormal lymph nodes in serial computed tomography (CT) exams. Methods: Our method leverages initial identification of enlarged (abnormal) lymph nodes in the baseline scan. We then identify an approximate region for the node in the follow-up scans using nonrigid image registration. The baseline scan is also used to locate regions of normal, non-nodal tissue surrounding the lymph node and to map them onto the follow-up scans, in order to reduce the search space to locate the lymph node on the follow-up scans. Adaptive region-growing and clustering algorithms are then used to obtain the final contours for segmentation. We applied our method to 24 distinct enlarged lymph nodes at multiple time points from 14 patients. The scan at the earlier time point was used as the baseline scan to be used in evaluating the follow-up scan, resulting in 70 total test cases (e.g., a series of scans obtained at 4 time points results in 3 test cases). For each of the 70 cases, a ''reference standard'' was obtained by manual segmentation by a radiologist. Assessment according to response evaluation criteria in solid tumors (RECIST) using our method agreed with RECIST assessments made using the reference standard segmentations in all test cases, and by calculating node overlap ratio and Hausdorff distance between the computer and radiologist-generated contours. Results: Compared to the reference standard, our method made the correct RECIST assessment for all 70 cases. The average overlap ratio was 80.7 {+-} 9.7% s.d., and the average Hausdorff distance was 3.2 {+-} 1.8 mm s.d. The concordance correlation between automated and manual segmentations was 0.978 (95% confidence interval 0.962, 0.984). The 100% agreement in our sample between our method and the standard with regard to RECIST classification suggests that the true disagreement rate is no more than 6%. Conclusions: Our automated lymph node segmentation method achieves excellent overall segmentation performance and provides equivalent RECIST assessment. It potentially will be useful to streamline and improve cancer lesion measurement and tracking and to improve assessment of cancer treatment response.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Automatic Segmentation and Online virtualCT in Head-and-Neck Adaptive Radiation Therapy

Purpose: The purpose of this work was to develop and validate an efficient and automatic strategy to generate online virtual computed tomography (CT) scans for adaptive radiation therapy (ART) in head-and-neck (HN) cancer treatment. Method: We retrospectively analyzed 20 patients, treated with intensity modulated radiation therapy (IMRT), for an HN malignancy. Different anatomical structures were considered: mandible, parotid glands, and nodal gross tumor volume (nGTV). We generated 28 virtualCT scans by means of nonrigid registration of simulation computed tomography (CTsim) and cone beam CT images (CBCTs), acquired for patient setup. We validated our approach by considering the real replanning CT (CTrepl) as ground truth. We computed the Dice coefficient (DSC), center of mass (COM) distance, and root mean square error (RMSE) between correspondent points located on the automatically segmented structures on CBCT and virtualCT. Results: Residual deformation between CTrepl and CBCT was below one voxel. Median DSC was around 0.8 for mandible and parotid glands, but only 0.55 for nGTV, because of the fairly homogeneous surrounding soft tissues and of its small volume. Median COM distance and RMSE were comparable with image resolution. No significant correlation between RMSE and initial or final deformation was found. Conclusion: The analysis provides evidence that deformable image registration may contribute significantly in reducing the need of full CT-based replanning in HN radiation therapy by supporting swift and objective decision-making in clinical practice. Further work is needed to strengthen algorithm potential in nGTV localization.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Online Adaptive Replanning Method for Prostate Radiotherapy

Purpose: To report the application of an adaptive replanning technique for prostate cancer radiotherapy (RT), consisting of two steps: (1) segment aperture morphing (SAM), and (2) segment weight optimization (SWO), to account for interfraction variations. Methods and Materials: The new 'SAM+SWO' scheme was retroactively applied to the daily CT images acquired for 10 prostate cancer patients on a linear accelerator and CT-on-Rails combination during the course of RT. Doses generated by the SAM+SWO scheme based on the daily CT images were compared with doses generated after patient repositioning using the current planning target volume (PTV) margin (5 mm, 3 mm toward rectum) and a reduced margin (2 mm), along with full reoptimization scans based on the daily CT images to evaluate dosimetry benefits. Results: For all cases studied, the online replanning method provided significantly better target coverage when compared with repositioning with reduced PTV (13% increase in minimum prostate dose) and improved organ sparing when compared with repositioning with regular PTV (13% decrease in the generalized equivalent uniform dose of rectum). The time required to complete the online replanning process was 6 {+-} 2 minutes. Conclusion: The proposed online replanning method can be used to account for interfraction variations for prostate RT with a practically acceptable time frame (5-10 min) and with significant dosimetric benefits. On the basis of this study, the developed online replanning scheme is being implemented in the clinic for prostate RT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

THE CHANDRA CARINA COMPLEX PROJECT: DECIPHERING THE ENIGMA OF CARINA'S DIFFUSE X-RAY EMISSION

We present a 1.42 deg{sup 2} mosaic of diffuse X-ray emission in the Great Nebula in Carina from the Chandra X-ray Observatory Advanced CCD Imaging Spectrometer camera. After removing >14,000 X-ray point sources from the field, we smooth the remaining unresolved emission, tessellate it into segments of similar apparent surface brightness, and perform X-ray spectral fitting on those tessellates to infer the intrinsic properties of the X-ray-emitting plasma. By modeling faint resolved point sources, we estimate the contribution to the extended X-ray emission from unresolved point sources and show that the vast majority of Carina's unresolved X-ray emission is truly diffuse. Line-like correlated residuals in the X-ray spectral fits suggest that substantial X-ray emission is generated by charge exchange at the interfaces between Carina's hot, rarefied plasma and its many cold neutral pillars, ridges, and clumps.

79 ASTRONOMY AND ASTROPHYSICS↗

Ultrasonic Phased Array Sound Field Mapping Through Large-Bore Coarse Grained Cast Austenitic Stainless Steel (CASS) Piping Materials

A sound field beam mapping exercise was conducted to further understand the effects of coarse grained microstructures found in CASS materials on phased array ultrasonic wave propagation. Laboratory measurements were made on three CASS specimens with different microstructures; the specimens were polished and etched to reveal measurable grain sizes, shapes and orientations. Three longitudinal, phased array probes were fixed on a specimen's outside diameter with the sound field directed toward one end (face) of the pipe segment over a fixed range of angles. A point receiver was raster scanned over the surface of the specimen face generating a sound field image. A slice of CASS material was then removed from the specimen end and the beam mapping exercise repeated. The sound fields acquired were analyzed for spot size, coherency, and beam redirection. Analyses were conducted between the resulting sound fields and the microstructural characteristics of each specimen.

Ultrasonic, Phased Array, NDE, Austenitic Steel, B↗

A reference tissue atlas for the human kidney

Kidney Precision Medicine Project (KPMP) is building a spatially specified human kidney tissue atlas in health and disease with single-cell resolution. Here, we describe the construction of an integrated reference map of cells, pathways, and genes using unaffected regions of nephrectomy tissues and undiseased human biopsies from 56 adult subjects. We use single-cell/nucleus transcriptomics, subsegmental laser microdissection transcriptomics and proteomics, near-single-cell proteomics, 3D and CODEX imaging, and spatial metabolomics to hierarchically identify genes, pathways, and cells. Integrated data from these different technologies coherently identify cell types/subtypes within different nephron segments and the interstitium. These profiles describe cell-level functional organization of the kidney following its physiological functions and link cell subtypes to genes, proteins, metabolites, and pathways. They further show that messenger RNA levels along the nephron are congruent with the subsegmental physiological activity. This reference atlas provides a framework for the classification of kidney disease when multiple molecular mechanisms underlie convergent clinical phenotypes.

59 BASIC BIOLOGICAL SCIENCES↗

LEU-Mo Fuel Out-of-Pile Characterization for TUM (Final Report)

The Technische Universität München (TUM) located in Germany requested that Pacific Northwest National Laboratory (PNNL) perform thermal-physical property measurement services for determining the thermal conductivities of irradiated U-Mo dispersion fuel samples. Two dispersion fuel segments containing U-7Mo dispersion fuel in an Al-2wt% Si matrix harvested from the AFIP-1 irradiation experiment were provided to PNNL for this effort. The segments were sectioned into samples for pycnometry (density) and laser flash analysis (thermal diffusivity), differential scanning calorimetry (specific heat capacity), and optical metallography (thickness, image analysis). This report summarizes the findings of the analysis performed at TUM’s request.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Quantitative Insight to Fission Gas Bubble Distribution in Irradiated Annular U-10Zr Metallic Fuel Using Deep Learning

U-10Zr Metal fuel is a promising nuclear fuel candidate for next-generation sodium-cooled fast spectrum reactors. Porosity is one of the key facts to impact the performance of metallic fuel. Additionally, a mechanical understanding of fission gas bubbles evolution behavior is a prerequisite for fuel development and qualification. Previous study of fission gas bubbles relied on a simple threshold method working on low resolution optical microscopy images, which has challenges in recognizing bubble boundaries, and caused inaccurate statistics of bubble properties. In this paper, a pre-trained deep learning model on Scanning Electron Microscopy (SEM) images from an annular U-10Zr fuel (AF1), was applied to another U-10Zr annular fuel (AF2). More accurate fission gas bubble segmentation results were generated, which leads to more precise qualitative analysis on the morphology, size, density, and orientation of bubbles. Furthermore, we investigated the lanthanide movement along the radial temperature gradient and obtained conclusive findings.

36 MATERIALS SCIENCE↗

Correlative Surface Imaging Reveals Chemical Signatures for Bacterial Hotspots on Plant Roots

The rhizosphere is arguably the most complex microbial habitat on earth, comprising an integrated network of plant roots, soil and a highly diverse microbial community (the rhizosphere microbiome)1. Understanding, predicting and controlling plant-microbe interactions in the rhizosphere will allow us to harness the plant microbiome as a means to increase or restore plant ecosystem productivity, improve plant responses to a wide range of environmental perturbations, and mitigate effects of climate change by designing ecosystems for long-term soil carbon storage1. To this end, it is imperative to develop new molecular approaches with high spatial resolution to capture interactions at the plant-microbe, microbe-microbe, and plant-plant interfaces. In this work, we designed an imaging sample holder that allows integrated surface imaging tools to map the same locations of a plant root-microbe interface with submicron lateral resolutions, providing novel in vivo analysis of root-microbe interactions. Specifically, confocal fluorescence microscopy, time-of-flight secondary ion mass spectrometry (ToF-SIMS), X-ray photoelectron spectroscopy (XPS), and scanning electron microscope (SEM) were used for the first time for correlative imaging of the Brachypodium distachyon root and its interaction with Pseudomonas SW25, a typical plant growth-promoting soil bacterium. Imaging data suggest that the root surface is inhomogeneous and that the interaction between Pseudomonas and Brachypodium roots was confined to only few spots along the sampled root segments and that the bacterial attachment spots were enriched in Na- and S-related and high-mass organic species. We conclude that attachment of the Pseudomonas cells to the root surface is outcompeted by strong root-soil mineral interactions but facilitated by formation of extracellular polymeric substances (EPS).

Plant root, Plant growth-promoting bacteria, soil,↗

Analytic reconstruction algorithms for triple-source CT with horizontal data truncation

Purpose: This paper explores a triple-source imaging method with horizontal data truncation to enlarge the field of view (FOV) for big objects. Methods: The study is conducted by using theoretical analysis, mathematical deduction, and numerical simulations. The proposed algorithms are implemented in c + + and MATLAB. While the basic platform is constructed in MATLAB, the computationally intensive segments are coded in c + +, which are linked via a MEX interface. Results: A triple-source circular scanning configuration with horizontal data truncation is developed, where three pairs of x-ray sources and detectors are unevenly distributed on the same circle to cover the whole imaging object. For this triple-source configuration, a fan-beam filtered backprojection-type algorithm is derived for truncated full-scan projections without data rebinning. The algorithm is also extended for horizontally truncated half-scan projections and cone-beam projections in a Feldkamp-type framework. Using their method, the FOV is enlarged twofold to threefold to scan bigger objects with high speed and quality. The numerical simulation results confirm the correctness and effectiveness of the developed algorithms. Conclusions: The triple-source scanning configuration with horizontal data truncation cannot only keep most of the advantages of a traditional multisource system but also cover a larger FOV for big imaging objects. In addition, because the filtering is shift-invariant, the proposed algorithms are very fast and easily parallelized on graphic processing units.

60 APPLIED LIFE SCIENCES↗

A reusable neural network pipeline for unidirectional fiber segmentation

Abstract Fiber-reinforced ceramic-matrix composites are advanced, temperature resistant materials with applications in aerospace engineering. Their analysis involves the detection and separation of fibers, embedded in a fiber bed, from an imaged sample. Currently, this is mostly done using semi-supervised techniques. Here, we present an open, automated computational pipeline to detect fibers from a tomographically reconstructed X-ray volume. We apply our pipeline to a non-trivial dataset by Larson et al . To separate the fibers in these samples, we tested four different architectures of convolutional neural networks. When comparing our neural network approach to a semi-supervised one, we obtained Dice and Matthews coefficients reaching up to 98%, showing that these automated approaches can match human-supervised methods, in some cases separating fibers that human-curated algorithms could not find. The software written for this project is open source, released under a permissive license, and can be freely adapted and re-used in other domains.

79 ASTRONOMY AND ASTROPHYSICS↗

Frequency and imaging features of abdominal immune-related adverse events in metastatic lung cancer patients treated with PD-1 inhibitor

Purpose: To investigate the frequency and imaging features of radiographically evident abdominal immune-related adverse events (irAEs) in patients with metastatic non-small-cell lung cancer (NSCLC) treated with PD-1 inhibitors. Methods: This retrospective study included 137 patients with metastatic NSCLC treated with PD-1 inhibitor nivolumab monotherapy (75 women; median age: 65 years), who had a baseline CT and at least one follow-up abdomen CT during therapy. Baseline and all follow-up abdominal CTs performed for monitoring of nivolumab therapy were reviewed to identify the organ-specific abdominal irAEs including colitis/enteritis, hepatitis, biliary toxicity, pancreatitis, nephritis, sarcoid-like reaction, and pancreatic and adrenal atrophy. Their frequency and imaging features were described. Results: Eighteen (13%) patients had radiologically identified abdominal irAEs (median 2.1 months after starting nivolumab; interquartile range 1.17–5.83 months); 16 patients developed enteritis/colitis (12 pancolitis, two segmental colitis, one enterocolitis, one enteritis), two hepatitis, one adrenalitis. One patient with hepatitis also developed colitis/enteritis. Radiographic abdominal irAE occurred after nivolumab therapy was discontinued in six patients before any subsequent therapy was started. IrAEs prompted nivolumab interruption and treatment with steroids in four patients (three colitis/enteritis, one hepatitis). Most common CT features of colitis/enteritis included mesenteric hyperemia (n = 15), bowel wall thickening (n = 13), mucosal hyperenhancement (n = 10), and fluid-filled colon (n = 9). Conclusion: Abdominal irAEs were detected on CT in 13% of NSCLC patients treated with nivolumab, and colitis, in the pancolitis form, was the most common irAE. Given the expanding role of immunotherapy, radiologists should be aware of the frequency and imaging manifestations of abdominal irAEs and the impact on patient management.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

3D TEM reconstruction and segmentation process of laminar bio-nanocomposites

The microstructure of laminar bio-nanocomposites (Poly (lactic acid)(PLA)/clay) depends on the amount of clay platelet opening after integration with the polymer matrix and determines the final properties of the material. Transmission electron microscopy (TEM) technique is the only one that can provide a direct observation of the layer dispersion and the degree of exfoliation. However, the orientation of the clay platelets, which affects the final properties, is practically immeasurable from a single 2D TEM image. This issue can be overcome using transmission electron tomography (ET), a technique that allows the complete 3D characterization of the structure, including the measurement of the orientation of clay platelets, their morphology and their 3D distribution. ET involves a 3D reconstruction of the study volume and a subsequent segmentation of the study object. Currently, accurate segmentation is performed manually, which is inefficient and tedious. The aim of this work is to propose an objective/automated segmentation methodology process of a 3D TEM tomography reconstruction. In this method the segmentation threshold is optimized by minimizing the variation of the dimensions of the segmented objects and matching the segmented V{sub clay} (%) and the actual one. The method is first validated using a fictitious set of objects, and then applied on a nanocomposite.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Automatic detection of large pulmonary solid nodules in thoracic CT images

Purpose: Current computer-aided detection (CAD) systems for pulmonary nodules in computed tomography (CT) scans have a good performance for relatively small nodules, but often fail to detect the much rarer larger nodules, which are more likely to be cancerous. We present a novel CAD system specifically designed to detect solid nodules larger than 10 mm. Methods: The proposed detection pipeline is initiated by a three-dimensional lung segmentation algorithm optimized to include large nodules attached to the pleural wall via morphological processing. An additional preprocessing is used to mask out structures outside the pleural space to ensure that pleural and parenchymal nodules have a similar appearance. Next, nodule candidates are obtained via a multistage process of thresholding and morphological operations, to detect both larger and smaller candidates. After segmenting each candidate, a set of 24 features based on intensity, shape, blobness, and spatial context are computed. A radial basis support vector machine (SVM) classifier was used to classify nodule candidates, and performance was evaluated using ten-fold cross-validation on the full publicly available lung image database consortium database. Results: The proposed CAD system reaches a sensitivity of 98.3% (234/238) and 94.1% (224/238) large nodules at an average of 4.0 and 1.0 false positives/scan, respectively. Conclusions: The authors conclude that the proposed dedicated CAD system for large pulmonary nodules can identify the vast majority of highly suspicious lesions in thoracic CT scans with a small number of false positives.

60 APPLIED LIFE SCIENCES↗