Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ION SOURCE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,351 records · Page 75

The middle atmosphere

A quick introduction to some of the important electrical properties, and to the factors that influence them and their variability are provided. The following topics are discussed: (1) production of ionization; (2) ion concentration; (3) ion composition; and (4) variability of the various sources of middle atmospheric ionization.

Reid, G. C.↗

Theory of plasma contractors for electrodynamic tethered satellite systems

Recent data from ground and space experiments indicate that plasma releases from an object dramatically reduce the sheath impedance between the object and the ambient plasma surrounding it. Available data is in qualitative accord with the theory developed to quantify the flow of current in the sheath. Electron transport in the theory is based on a fluid model of a collisionless plasma with an effective collision frequency comparable to frequencies of plasma oscillations. The theory leads to low effective impedances varying inversely with the square root of the injected plasma density. To support such a low impedance mode of operation using an argon plasma source for example requires that only one argon ion be injected for each thirty electrons extracted from the ambient plasma. The required plasma flow rates are quite low; to extract one ampere of electron current requires a mass flow rate of about one gram of argon per day.

Parks, D. E.↗

The temperature of solar flares determined from X-ray spectral line ratios

The effect on derived solar flare plasma temperatures of (1) a power-law distribution of emission measure as a function of temperature, (2) a high-temperature isothermal source coupled to a low-temperature power-law distribution of emission measure, and (3) two isothermal sources is calculated for line ratios involving the ions S XV, Ca XIX, Ca XX, Fe XXV, Ni XXVII, and Fe XXVI. It is shown that if the Fe XXV temperature is less than about 25 million K, as is true for the majority of flares, then about 75 percent or more of the emission measure is produced by plasma at temperatures equal to or less than the Fe XXV temperature plus about 3 million K. If the Fe XXV temperature is 20 million K or higher, this percentage can be larger. This result is obtained even if a superhot component exists that extends up to several hundred million degrees. Temperatures determined from Fe XXVI demonstrate the presence of a superhot component.

Doschek, G. A.↗

Theory of plasma contactors for electrodynamic tethered satellite systems

Recent data from ground and space experiments indicate that plasma releases from an object dramatically reduce the sheath impedance between the object and the ambient plasma surrounding it. Available data is in qualitative accord with the theory developed to quantify the flow of current in the sheath. Electron transport in the theory is based on a fluid model of a collisionless plasma with an effective collision frequency comparable to frequencies of plasma oscillations. The theory leads to low effective impedances varying inversely with the square root of the injected plasma density. To support such a low impedance mode of operation using an argon plasma source, for example, requires that only one argon ion be injected for each thirty electrons extracted from the ambient plasma. The required plasma flow rates are quite low; to extract one ampere of electron current requires a mass flow rate of about one gram of argon per day.

Parks, D. E.↗

Particle acceleration and wave emissions associated with the formation of auroral cavities and enhancements

A unified model is presented which interrelates the various processes involved in auroral particle acceleration and the associated wave emissions, and it is shown how energy is coupled from the magnetosphere into the ionosphere. The phenomena in the magnetotail which can provide the source of free energy for the perpendicular electrostatic shocks are identified along with the associated potential structures in the nightside auroral region. The characteristics of the particle acceleration produced by the shock are described, including efficiency and energy transport between magnetospheric and ionospheric plasmas, the properties of the particle distributions throughout the shock region and return current regions, and the associated wave emissions. The source of free energy for the generation of ion conics is identified, as are the signatures for the formation of plasma cavities and/or enhancements.

Winglee, R. M.↗

Gated photomultiplier response characterization for DIAL measurements

The characteristics of various detector responses are studied to understand the cause of various systematic biases and to minimize these undesirable effects in measurements of transient signals with large dynamic range. Signal-induced bias, gain variation, and the linearity of commonly used gated photomultipliers in the current integrating mode are quantitatively evaluated. Analysis of the results indicates that impurity ions inside the photomultiplier tubes (PMT) are the source of the signal induced bias and gain variation. Two different PMTs used in this study show significant differences in the magnitude and decay behavior of signal-induced bias. It was found that it can be minimized by using an external amplifier to reduce PMT gain, and by applying a low potential between the cathode and first dynode. The linearity of a PMT is also studied over a large dynamic range of input intensities employing a new technique which does not require an absolute calibration. The result of this study shows that the photomultiplier response is linear only for a limited input intensity range below a certain anode current.

Lee, H. Sang↗

Space Power Architectures for NASA Missions: The Applicability and Benefits of Advanced Power and Electric Propulsion

The relative importance of electrical power systems as compared with other spacecraft bus systems is examined. The quantified benefits of advanced space power architectures for NASA Earth Science, Space Science, and Human Exploration and Development of Space (HEDS) missions is then presented. Advanced space power technologies highlighted include high specific power solar arrays, regenerative fuel cells, Stirling radioisotope power sources, flywheel energy storage and attitude control, lithium ion polymer energy storage and advanced power management and distribution.

Hoffman, David J.↗

Applications of High Etendue Line-Profile Spectro-Polarimetry to the Study of the Atmospheric and Magnetospheric Environments of the Jovian Icy Moons

Electrodynamic effects play a significant, global role in the state and energization of the Earth's ionosphere/magnetosphere, but even more so on Jupiter, where the auroral energy input is four orders of magnitude greater than on Earth. The Jovian magnetosphere is distinguished from Earth's by its rapid rotation rate and contributions from satellite atmospheres and internal plasma sources. The electrodynamic effects of these factors have a key role in the state and energization of the ionosphere-corona- plasmasphere system of the planet and its interaction with Io and the icy satellites. Several large scale interacting processes determine conditions near the icy moons beginning with their tenuous atmospheres produced from sputtering, evaporative, and tectonic/volcanic sources, extending out to exospheres that merge with ions and neutrals in the Jovian magnetosphere. This dynamic environment is dependent on a complex network of magnetospheric currents that act on global scales. Field aligned currents connect the satellites and the middle and tail magnetospheric regions to the Jupiter's poles via flux tubes that produce as bright auroral and satellite footprint emissions in the upper atmosphere. This large scale transfer of mass, momentum, and energy (e.g. waves, currents) means that a combination of complementary diagnostics of the plasma, neutral, and and field network must be obtained near simultaneously to correctly interpret the results. This presentation discusses the applicability of UV spatial heterodyne spectroscopy (SHS) to the broad study of this system on scales from satellite surfaces to Jupiter's aurora and corona.

Harris, Walter M.↗

Artificial cells: prospects for biotechnology

A variety of techniques can now be used to alter the genome of a cell. Although these techniques are very powerful, they have limitations related to cost and efficiency of scale. Artificial cells designed for specific applications combine properties of biological systems such as nanoscale efficiency, self-organization and adaptability at relatively low cost. Individual components needed for such structures have already been developed, and now the main challenge is to integrate them in functional microscopic compartments. It will then become possible to design and construct communities of artificial cells that can perform different tasks related to therapeutic and diagnostic applications.

Review↗

Observation of Bernstein Waves Excited by Newborn Interstellar Pickup Ions in the Solar Wind

A recent examination of 1.9 s magnetic field data recorded by the Voyager 2 spacecraft in transit to Jupiter revealed several instances of strongly aliased spectra suggestive of unresolved high-frequency magnetic fluctuations at 4.4 AU. A closer examination of these intervals using the highest resolution data available revealed one clear instance of wave activity at spacecraft frame frequencies from 0.2 to 1 Hz. Using various analysis techniques, we have characterized these fluctuations as Bernstein mode waves excited by newborn interstellar pickup ions. We can find no other interpretation or source consistent with the observations, but this interpretation is not without questions. In this paper, we report a detailed analysis of the waves, including their frequency and polarization, that supports our interpretation.

magnetic fields↗

Analytical and Experimental Studies of Leak Location and Environment Characterization for the International Space Station

The International Space Station program is developing a robotically-operated leak locator tool to be used externally. The tool would consist of a Residual Gas Analyzer for partial pressure measurements and a full range pressure gauge for total pressure measurements. The primary application is to detect NH3 coolant leaks in the ISS thermal control system.An analytical model of leak plume physics is presented that can account for effusive flow as well as plumes produced by sonic orifices and thruster operations. This model is used along with knowledge of typical RGA and full range gauge performance to analyze the expected instrument sensitivity to ISS leaks of various sizes and relative locations (directionality).The paper also presents experimental results of leak simulation testing in a large thermal vacuum chamber at NASA Goddard Space Flight Center. This test characterized instrument sensitivity as a function of leak rates ranging from 1 lbmyr. to about 1 lbmday. This data may represent the first measurements collected by an RGA or ion gauge system monitoring off-axis point sources as a function of location and orientation. Test results are compared to the analytical model and used to propose strategies for on-orbit leak location and environment characterization using the proposed instrument while taking into account local ISS conditions and the effects of ramwake flows and structural shadowing within low Earth orbit.

Leak Locator↗

Analytical and Experimental Studies of Leak Location and Environment Characterization for the International Space Station

The International Space Station program is developing a robotically-operated leak locator tool to be used externally. The tool would consist of a Residual Gas Analyzer for partial pressure measurements and a full range pressure gauge for total pressure measurements. The primary application is to detect NH3 coolant leaks in the ISS thermal control system. An analytical model of leak plume physics is presented that can account for effusive flow as well as plumes produced by sonic orifices and thruster operations. This model is used along with knowledge of typical RGA and full range gauge performance to analyze the expected instrument sensitivity to ISS leaks of various sizes and relative locations ("directionality"). The paper also presents experimental results of leak simulation testing in a large thermal vacuum chamber at NASA Goddard Space Flight Center. This test characterized instrument sensitivity as a function of leak rates ranging from 1 lb-mass/yr. to about 1 lb-mass/day. This data may represent the first measurements collected by an RGA or ion gauge system monitoring off-axis point sources as a function of location and orientation. Test results are compared to the analytical model and used to propose strategies for on-orbit leak location and environment characterization using the proposed instrument while taking into account local ISS conditions and the effects of ram/wake flows and structural shadowing within low Earth orbit.

000000↗

Effect of the Thermal Stability and Reactivity of Fullerenes on Ion Engine Propellant Applications

Because vapor phase fullerene molecules collide with high temperature surfaces at both the cathode in DC discharges and at the walls of vapor sources, knowledge of the thermal stability and material compatibility of fullerenes is important for ion thruster applications. Here, we present a study of the high temperature behavior of fullerenes. We find that when C 60 and C 7O are maintained at temperatures above 1073 K, or are wxposed to hot metal surfaces, significant degradation occurs. We find an activation energy of 261.5 kJ/mol for this process. At temperatures below 873 K, no breakdown of fullerenes can be detected, even after heating for 6 hours. The effect of these findings on C 60 ion thruster design is discussed. Our present C 60 ion thruster experiment is also described.

fullerenes↗

Interplanetary Overlay Network Bundle Protocol Implementation

The Interplanetary Overlay Network (ION) system's BP package, an implementation of the Delay-Tolerant Networking (DTN) Bundle Protocol (BP) and supporting services, has been specifically designed to be suitable for use on deep-space robotic vehicles. Although the ION BP implementation is unique in its use of zero-copy objects for high performance, and in its use of resource-sensitive rate control, it is fully interoperable with other implementations of the BP specification (Internet RFC 5050). The ION BP implementation is built using the same software infrastructure that underlies the implementation of the CCSDS (Consultative Committee for Space Data Systems) File Delivery Protocol (CFDP) built into the flight software of Deep Impact. It is designed to minimize resource consumption, while maximizing operational robustness. For example, no dynamic allocation of system memory is required. Like all the other ION packages, ION's BP implementation is designed to port readily between Linux and Solaris (for easy development and for ground system operations) and VxWorks (for flight systems operations). The exact same source code is exercised in both environments. Initially included in the ION BP implementations are the following: libraries of functions used in constructing bundle forwarders and convergence-layer (CL) input and output adapters; a simple prototype bundle forwarder and associated CL adapters designed to run over an IPbased local area network; administrative tools for managing a simple DTN infrastructure built from these components; a background daemon process that silently destroys bundles whose time-to-live intervals have expired; a library of functions exposed to applications, enabling them to issue and receive data encapsulated in DTN bundles; and some simple applications that can be used for system checkout and benchmarking.

Burleigh, Scott C.↗

Quantum Simulation of Polarized Light-Induced Electron Transfer with a Trapped-Ion Qutrit System

Electron transfer within and between molecules is crucial in chemistry, biochemistry, and energy science. Here this study describes a quantum simulation method that explores the influence of light polarization on electron transfer between two molecules. By implementing precise and coherent control among the quantum states of trapped atomic ions, we can induce quantum dynamics that mimic the electron-transfer dynamics in molecules. We use three-level systems (qutrits), rather than traditional two-level systems (qubits), to enhance the simulation efficiency and realize high-fidelity simulations of electron-transfer dynamics. We treat the quantum interference between the electron coupling pathways from a donor with two degenerate excited states to an acceptor and analyze the transfer efficiency. We also examine the potential error sources that enter the quantum simulations. The trapped-ion systems have favorable scalings with system size compared to those of classical computers, promising access to richer electron-transfer simulations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Anatomy of Protein Electrospray Ionization Mass Spectra by Superconducting Tunnel Junction Mass and Energy Spectrometry

Cryogenic superconducting tunnel junction (STJ) detectors have the advantage of single-particle sensitivity, high quantum efficiency, low noise, and the ability to detect the time and relative impact energy of deposited ions. This makes them attractive for use in mass spectrometry (MS) and as a form of energy spectrometry. STJ cryodetectors have been coupled to time-offlight (TOF) mass spectrometers equipped with a matrix-assisted laser desorption ionization (MALDI) source and to an electrospray ionization (ESI) TOF mass spectrometer. Here, a lab-made linear ion trap (LIT) mass spectrometer system was coupled to an ESI source and a 16-channel Nb-STJ array with improved readout electronics. The goal was to investigate fundamentals of ESI-generated protein ions by further exploiting the advantage of resolving these ions in a third dimension of the relative energy deposited into the STJs. The proteins equine cytochrome c, bovine carbonic anhydrase, bovine serum albumin, and murine immunoglobulin G were studied using this ESI-LIT-STJ-MS instrument. Multiply charged monomers, multimers, and fragments from metastable ions were resolved from monomer peaks by differences in ion deposition energy even when these ions have the same mass-to-charge ratio as the corresponding monomer. The determination of fragment mass from metastable decomposition is accomplished without knowing the charge state of the fragment. The average charge state of the multimers is reduced with each addition of a protein which is a direct reflection of the surface area available for charging. Multiply charged in-source fragments have also been observed and distinguished in the mass spectrum of carbonic anhydrase by using the differences in the energy deposited in the STJs.

42 ENGINEERING↗

Evaluation of Pulse Counting for the Mars Organic Mass Analyzer (MOMA) Ion Trap Detection Scheme

The Mars Organic Mass Analyzer is being developed at Goddard Space Flight Center to identify organics and possible biological compounds on Mars. In the process of characterizing mass spectrometer size, weight, and power consumption, the use of pulse counting was considered for ion detection. Pulse counting has advantages over analog-mode amplification of the electron multiplier signal. Some advantages are reduced size of electronic components, low power consumption, ability to remotely characterize detector performance, and avoidance of analog circuit noise. The use of pulse counting as a detection method with ion trap instruments is relatively rare. However, with the recent development of high performance electrical components, this detection method is quite suitable and can demonstrate significant advantages over analog methods. Methods A prototype quadrupole ion trap mass spectrometer with an internal electron ionization source was used as a test setup to develop and evaluate the pulse-counting method. The anode signal from the electron multiplier was preamplified. The an1plified signal was fed into a fast comparator for pulse-level discrimination. The output of the comparator was fed directly into a Xilinx FPGA development board. Verilog HDL software was written to bin the counts at user-selectable intervals. This system was able to count pulses at rates in the GHz range. The stored ion count nun1ber per bin was transferred to custom ion trap control software. Pulse-counting mass spectra were compared with mass spectra obtained using the standard analog-mode ion detection. Prelin1inary Data Preliminary mass spectra have been obtained for both analog mode and pulse-counting mode under several sets of instrument operating conditions. Comparison of the spectra revealed better peak shapes for pulse-counting mode. Noise levels are as good as, or better than, analog-mode detection noise levels. To artificially force ion pile-up conditions, the ion trap was overfilled and ions were ejected at very high scan rates. Pile-up of ions was not significant for the ion trap under investigation even though the ions are ejected in so-called 'ion-micro packets'. It was found that pulse counting mode had higher dynamic range than analog mode, and that the first amplification stage in analog mode can distort mass peaks. The inherent speed of the pulse counting method also proved to be beneficial to ion trap operation and ion ejection characterization. Very high scan rates were possible with pulse counting since the digital circuitry response time is so much smaller than with the analog method. Careful investigation of the pulse-counting data also allowed observation of the applied resonant ejection frequency during mass analysis. Ejection of ion micro packets could be clearly observed in the binned data. A second oscillation frequency, much lower than the secular frequency, was also observed. Such an effect was earlier attributed to the oscillation of the total plasma cloud in the ion trap. While the components used to implement pulse counting are quite advanced, due to their prevalence in consumer electronics, the cost of this detection system is no more than that of an analog mode system. Total pulse-counting detection system electronics cost is under $250

Van Amerom, Friso H.↗