Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “IMPLANTS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,351 records · Page 75

Relationship between isotope half-life and prostatic edema for optimal prostate dose coverage in permanent seed implants

The robustness of treatment planning to prostatic edema for three different isotopes ({sup 125}I, {sup 103}Pd, and {sup 131}Cs) is explored using dynamical dose calculations on 25 different clinical prostate cases. The treatment plans were made using the inverse planning by simulated annealing (IPSA) algorithm. The prescription was 144, 127, and 125 Gy for {sup 125}I, {sup 131}Cs, and {sup 103}Pd, respectively. For each isotope, three dose distribution schemes were used to impose different protection levels to the urethra: V{sub 120}=0%, V{sub 150}=0%, and V{sub 150}=30%. Eleven initial edema values were considered ranging from 1.0 (no edema) to 2.0 (100%). The edema was assumed to resolve exponentially with time. The prostate volume, seed positions, and seed activity were dynamically tracked to produce the final dose distribution. Edema decay half-lives of 10, 30, and 50 days were used. A total of 675 dynamical calculations were performed for each initial edema value. For the {sup 125}I isotope, limiting the urethra V{sub 120} to 0% leads to a prostate D{sub 90} under 140 Gy for initial edema values above 1.5. Planning with urethra V{sub 150} at 0% provides a good response to the edema; the prostate D{sub 90} remains higher than 140 Gy for edema values up to 1.8 and a half-life of 30 days or less. For {sup 103}Pd, the prostate D{sub 90} is under 97% of the prescription dose for approximately 66%, 40%, and 30% of edema values for urethra V{sub 120}=0%, V{sub 150}=0%, and V{sub 150}=30%, respectively. Similar behavior is seen for {sup 131}Cs and the center of the prostate becomes 'cold' for almost all edema scenarios. The magnitude of the edema following prostate brachytherapy, as well as the half-life of the isotope used and that of the edema resorption, all have important impacts on the dose distribution. The {sup 125}I isotope with its longer half-life is more robust to prostatic edema. Setting up good planning objectives can provide an adequate compromise between organ doses and robustness. This is even more important since seed misplacements will contribute to further degrade dose coverage.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

WE-A-17A-09: Exploiting Electromagnetic Technologies for Real-Time Seed Drop Position Validation in Permanent Implant Brachytherapy

Purpose: To report on preliminary results validating the performance of a specially designed LDR brachytherapy needle prototype possessing both electromagnetic (EM) tracking and seed drop detection abilities. Methods: An EM hollow needle prototype has been designed and constructed in collaboration with research partner Philips Healthcare. The needle possesses conventional 3D tracking capabilities, along with a novel seed drop detection mechanism exploiting local changes of electromagnetic properties generated by the passage of seeds in the needle's embedded sensor coils. These two capabilities are exploited by proprietary engineering and signal processing techniques to generate seed drop position estimates in real-time treatment delivery. The electromagnetic tracking system (EMTS) used for the experiment is the NDI Aurora Planar Field Generator. The experiment consisted of dropping a total of 35 seeds in a prismatic agarose phantom, and comparing the 3D seed drop positions of the EMTS to those obtained by an image analysis of subsequent micro-CT scans. Drop position error computations and statistical analysis were performed after a 3D registration of the two seed distributions. Results: Of the 35 seeds dropped in the phantom, 32 were properly detected by the needle prototype. Absolute drop position errors among the detected seeds ranged from 0.5 to 4.8 mm with mean and standard deviation values of 1.6 and 0.9 mm, respectively. Error measurements also include undesirable and uncontrollable effects such as seed motion upon deposition. The true accuracy performance of the needle prototype is therefore underestimated. Conclusion: This preliminary study demonstrates the potential benefits of EM technologies in detecting the passage of seeds in a hollow needle as a means of generating drop position estimates in real-time treatment delivery. Such tools could therefore represent a potentially interesting addition to existing brachytherapy protocols for rapid dosimetry validation. Equipments and fundings for this project were provided by Philips Medical.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Formation of Nanodimensional SiO{sub 2} Films on the Surface of a Free Si/Cu Film System by O{sub 2}{sup +} Ion Implantation

The composition and parameters of energy bands in thin SiO{sub 2} films grown on the surface of a free Si/Cu film system have been studied. It has been shown that unlike SiO{sub 2} films grown on thick films, the value of E{sub g} for thin SiO{sub 2} films is no higher than ~4.1 eV. This is explained by the presence of Si impurity atoms and nonstoichiometric oxides in the SiO{sub 2} film, which arise because of the impossibility of heating the system above 700 K.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Charging of Ion-Implanted Dielectrics by Electron Irradiation

The charging kinetics of Al{sub 2}O{sub 3} (sapphire) and SiO{sub 2} (α-quartz) dielectrics irradiated by inert gas ions (Ar{sup +}), metal ions (Ga{sup +}), and protons (H{sup +}) has been studied. It has been found that charging kinetics depends considerably on the type of irradiating ion. Also, it has been established that preirradiation of a dielectric target by an ionizing corpuscular radiation (protons, ions) substantially changes the charge characteristics of the dielectric surface. These differences depend on irradiating ion energy, which governs the depth of an accumulated negative charge layer versus the depth of ion preimplantation.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Comparative Photoluminescent Analysis of Point Defects in SiO{sub 2} Induced by Implantation of Ar{sup +} Ions and Neutron Irradiation

The introduction of Si{sup +} ions and ions of other elements into amorphous silicon dioxide during their interaction causes damage to the structural bonds, which is observed in the vibrational spectral bands. Pure SiO{sub 2} has no optical transitions but the bands of induced point defects appear in the photoluminescence spectrum when ions/neutrons are introduced. The generation of photoluminescence-active defects by fluxes of Ar{sup +} ion and thermal neutrons is compared. It is shown that the nature of damage to the structure is associated with both the specifics of the synthesis/processing of the material and the features of the interaction between the substance and ions (atomic collisions) and neutrons (collisions with atomic nuclei).

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Modulating the Pseudoelastic Response of NiTi Using Ion Implantation

Ni-ion irradiated NiTi is nearly 50% harder, retains 85% recoverable deformation, and has reduced hysteresis. This work explores the feasibility of using ion beam modification to modulate the austenite to martensite phase transformation in NiTi, thereby achieving novel or localized properties in near-surface regions.

36 MATERIALS SCIENCE↗

Modulating the Pseudoelastic Response of NiTi Using Ion Implantation

Ni-ion irradiated NiTi is nearly 50% harder, retains 85% recoverable deformation, and has reduced hysteresis. This work explores the feasibility of using ion beam modification to modulate the austenite to martensite phase transformation in NiTi, thereby achieving novel or localized properties in near-surface regions.

36 MATERIALS SCIENCE↗

Implantable Biofuel Cell

Explore the source record for details and available documents.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Characterization of Ion Implantation and Irradiation Effects in Interface-Dominated Metallic Composites

The candidate structural and fuel cladding materials for the next-generation nuclear power reactors must possess excellent irradiation damage tolerance, and high mechanical and thermal stability that present a challenge for materials design. Here we report an approach to engineer interphase boundaries in metallic composites to achieve superior resistance to void swelling and prevent loss of plastic deformability after irradiation. Model composite systems of face-centered-cubic (Cu) and body-centered-cubic (Nb, Mo or V) metals are used to elucidate the effects of boundary structure and spacing on the damage accumulation and mechanical properties after irradiation. Transmission electron microscopy (TEM) and nano-mechanical testing are used to characterize the irradiation response. A recent development in in situ straining in high-resolution TEM to measure lattice strains and thereby estimate local stresses corresponding to dislocation nucleation and migration is discussed as a capability that in future can enable quantitative characterization of defect interactions in irradiated materials. (authors)

36 MATERIALS SCIENCE↗