Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Grid services”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,351 records · Page 75

A Survey on Next-generation Power Grid Data Architecture

The operation and control of power grids will increasingly rely on data. A high-speed, reliable, flexible and secure data architecture is the prerequisite of the next-generation power grid. This paper summarizes the challenges in collecting and utilizing power grid data, and then provides reference data architecture for future power grids. Based on the data architecture deployment, related research on data architecture is reviewed and summarized in several categories including data measurement/actuation, data transmission, data service layer, data utilization, as well as two cross-cutting issues, interoperability and cyber security. Research gaps and future work are also presented.

You, Shutang↗

Enabling Cybersecurity, Situational Awareness and Resilience in Distribution Grids with High Penetration of Photovoltaics (CARE-PV) (Final Report)

Since legacy distribution systems have very limited visibility beyond the substation, high penetration of PV at the grid edge presents some unique operational challenges. One approach to address these challenges is to use information from advanced metering infrastructure (AMI) and µPMUs. However, exploiting this information is impacted by a number of factors, including multi-timescale measurements, volume of data generated, communication network impairments (e.g., information loss and latency) and susceptibility to cyber-attacks. Therefore, one of the critical tasks involved in the management of a distribution grid is to develop complete situational awareness by integrating cyber-security mechanisms with state estimation strategies and leveraging this situational awareness to assure energy services at strategic locations while exploiting AMI/PV inverter/ µPMU data. This CARE-PV project addresses the fundamental challenges in situational awareness and resilience to cyber and physical vectors by exploiting the synergy between innovative modeling, estimation, data analytics, testing and validation using smart PV inverters designed at K-State and facilities at NREL. Specifically, the project involved the development, testing and validation of the following novel enabling technologies: (Thrust 1) Resilience to cyber vectors that impact data integrity was addressed via a two-level defense strategy that combines cyber intrusion detection using self-learning, cooperative smart PV inverters, and a novel moving target defense framework to combat data integrity attacks. (Thrust 2) Resilience to cyber-physical vectors that impact situational awareness by limiting data availability was addressed via novel centralized and decentralized, sparsity-based static and dynamic state estimation approaches that enhance observability even when the underlying system is unobservable. (Thrust 3) Leveraging a unique probabilistic sensitivity analysis approach accompanied by one-of-a-kind dominant influencer set computation, the vulnerability of critical infrastructure at strategic locations was evaluated so that proactive PV-based control strategies can be used to support operations under normal/outage scenarios. These CARE-PV project innovations were demonstrated on both small-scale IEEE and larger utility-scale testbeds (Thrust 4). Feedback from Industry Advisory Board members was used to formulate a commercialization pathway for a subset of CARE-PV technologies. These CARE-PV technologies will ultimately lead to reliable and secure, large-scale integration of renewable energy and mitigate the risk of energy disruption resulting from cyber incidents and other emerging threats within the energy environment.

14 SOLAR ENERGY↗

ASEAN Technical Exchange Workshop for System Operators, Regulators, and Policymakers

This presentation provides an in-depth exploration of power system planning, cross-border electricity trading, and battery energy storage systems (BESS), offering actionable insights for system operators, regulators, and policymakers. The first section delves into power system planning and analysis, focusing on capacity expansion models and resource adequacy studies, including their role in optimizing system efficiency, managing emissions, and addressing system reliability risks. Key considerations, such as integration of transmission into generation planning and the forecasting versus optimization of customer distributed energy resources (DER) technologies, are explored. The session highlights critical trade-offs in spatial granularity and model runtimes, as well as the feasibility of aligning distribution investments with capacity expansion efforts. The second section examines cross-border electricity trading, with an emphasis on resource adequacy concepts such as reliability targets, loss of load expectation (LOLE), and planning reserve margins (PRM). Case studies on reserve market design and coordination across US regions provide insights into improving reserve deliverability and managing interregional power balance and congestion. This section also addresses market-to-market congestion management, including advanced strategies for high-voltage direct current (HVDC) optimization and ancillary service delivery. Finally, the presentation covers the rapid evolution of Battery Energy Storage Systems (BESS), highlighting their operational growth, regulatory frameworks, and use cases in grid flexibility, energy storage, and reliability. The discussion focuses on the benefits of BESS for system stability, resilience, and integration of renewable energy, offering insights into its role as a vital component in the transition toward a more sustainable and flexible grid. Key performance parameters, such as throughput, round-trip efficiency, and state of charge, are also examined.

25 ENERGY STORAGE↗

Introduction to the LaRC central scientific computing complex

The computers and associated equipment that make up the Central Scientific Computing Complex of the Langley Research Center are briefly described. The electronic networks that provide access to the various components of the complex and a number of areas that can be used by Langley and contractors staff for special applications (scientific visualization, image processing, software engineering, and grid generation) are also described. Flight simulation facilities that use the central computers are described. Management of the complex, procedures for its use, and available services and resources are discussed. This document is intended for new users of the complex, for current users who wish to keep appraised of changes, and for visitors who need to understand the role of central scientific computers at Langley.

Shoosmith, John N.↗

Smart Grids in Emerging Markets - Private Sector Perspectives

Information presented in this report is based on qualitative and quantitative data collection and analysis methods to provide an empirical understanding of barriers to private sector clean energy investment in emerging markets as it relates to smart grids. Through literature review, a survey, and a series of webinar dialogues, the U.S. Agency for International Development (USAID) and the U.S. Department of Energy's National Renewable Energy Laboratory (NREL) solicited input from private sector actors, including developers, project financiers, manufacturers, and technical assistance service providers on the challenges they face to market entry in developing and emerging markets, and their suggestions for improving market competitiveness.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Autonomous Inverter Controls for Resilient and Secure Grid Operation: Vector Control Design for Grid Forming

The project addresses both fundamental and practical challenges of GFM/GFL inverter control for the power grids with high inverter based resources (IBRs) penetration. A data- driven modeling technique is applied to accurately model dynamics of PWM inverters, including electromagnetic-transient (EMT). Systematic and integrative designs of grid- forming (GFM) and grid-following (GFL) primary controls are developed to guarantee system performance under either normal or abnormal operating conditions without violating constraints. This modeling and control framework provides black-start capability in case of an outage without relying on rotating generators, and its secondary control is also shown to enhance resilience against cyber-physical attacks.

14 SOLAR ENERGY↗

Hierarchical, Grid-Aware, and Economically Optimal Coordination of Distributed Energy Resources in Realistic Distribution Systems

Renewable portfolio standards are targeting high levels of variable solar photovoltaics (PV) in electric distribution systems, which makes reliability more challenging to maintain for distribution system operators (DSOs). Distributed energy resources (DERs), including smart, connected appliances and PV inverters, represent responsive grid resources that can provide flexibility to support the DSO in actively managing their networks to facilitate reliability under extreme levels of solar PV. This flexibility can also be used to optimize system operations with respect to economic signals from wholesale energy and ancillary service markets. Here, we present a novel hierarchical scheme that actively controls behind-the-meter DERs to reliably manage each unbalanced distribution feeder and exploits the available flexibility to ensure reliable operation and economically optimizes the entire distribution network. Each layer of the scheme employs advanced optimization methods at different timescales to ensure that the system operates within both grid and device limits. The hierarchy is validated in a large-scale realistic simulation based on data from the industry. Simulation results show that coordination of flexibility improves both system reliability and economics, and enables greater penetration of solar PV. Discussion is also provided on the practical viability of the required communications and controls to implement the presented scheme within a large DSO.

distribution network↗

A valuation framework for customers impacted by extreme temperature-related outages

Extreme temperature outages can lead to not just economic losses but also various non-energy impacts (NEI), such as increased mortality rates, property damage, and reduced productivity, due to significant degradation of indoor operating conditions caused by service disruptions. However, existing resilience assessment approaches lack specificity for extreme temperature conditions. They often overlook temperature-related mortality and neglect the customer characteristics and grid response in the calculation, despite the significant influence of these factors on NEI-related economic losses. This paper aims to address these gaps by introducing a comprehensive framework to estimate the impact of resilience enhancement not only on the direct economic losses incurred by customers but also on potential NEI, including mortality and the value of statistical life during extreme temperature-related outages. The proposed resilience valuation integrates customer characteristics and grid response variables based on a scalable grid simulation environment. This study adopts a holistic approach to quantify customer-oriented economic impacts, utilizing probabilistic loss scenarios that incorporate health-related factors and damage/loss models as a function of exposure for valuation. The proposed methodology is demonstrated through comparative resilient outage planning, using grid response models emulating a Texas weather zone during the 2021 winter storm Uri. The case study results show that enhanced outage planning with hardened infrastructure can improve the system resilience and thereby reduce the relative risk of mortality by 16% and save the total costs related to non-energy impacts by 74%. In conclusion, these findings underscore the efficacy of the framework by assessing the financial implications of each case, providing valuable insights for decision-makers and stakeholders involved in extreme-weather related resilience planning for risk management and mitigation strategies.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Smart Grid Enabled EVSE

The combined team of GE Global Research, Federal Express, National Renewable Energy Laboratory, and Consolidated Edison has successfully achieved the established goals contained within the Department of Energy’s Smart Grid Capable Electric Vehicle Supply Equipment funding opportunity. The final program product, shown charging two vehicles in Figure 1, reduces by nearly 50% the total installed system cost of the electric vehicle supply equipment (EVSE) as well as enabling a host of new Smart Grid enabled features. These include bi-directional communications, load control, utility message exchange and transaction management information. Using the new charging system, Utilities or energy service providers will now be able to monitor transportation related electrical loads on their distribution networks, send load control commands or preferences to individual systems, and then see measured responses. Installation owners will be able to authorize usage of the stations, monitor operations, and optimally control their electricity consumption. These features and cost reductions have been developed through a total system design solution.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Battery Energy Storage System (BESS) Licensing and Permitting [Slides]

This presentation provides an overview of the licensing, permitting, and regulatory frameworks governing Battery Energy Storage Systems (BESS) across multiple international contexts. It outlines foundational permitting considerations - including safety standards, siting requirements, regulatory and environmental obligations, and interconnection processes - alongside typical pathways for installation, approval, and inspection. The presentation summarizes key technical standards such as NFPA 855 and IEEE guidelines, and emphasizes best practices for safe and effective deployment. A series of detailed case studies from South Africa, Chile, Mexico, Brazil, Costa Rica, Honduras, and the Dominican Republic illustrates how different countries structure approval authority, evaluate environmental impacts, and integrate BESS into national grid systems. The deck concludes with insights on emerging challenges, including evolving regulatory frameworks, financial viability, and the need for pricing mechanisms that accurately value storage services.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Analyzing the Effects of Climate and Thermal Configuration on Community Energy Storage Systems (Presentation)

Community energy storage (CES) has been proposed to mitigate the high variation in output from renewable sources and reduce peak load on the electrical grid. Thousands of these systems may be distributed around the grid to provide benefits to local distribution circuits and to the grid as a whole when aggregated. CES must be low cost to purchase and install and also largely maintenance free through more than 10 years of service life to be acceptable to most utilities.Achieving the required system life time is a major uncertainty for lithium-ion batteries. The lifetime and immediate system performance of batteries can change drastically with battery temperature, which is a strong function of system packaging, local climate, electrical duty cycle, and other factors. In other Li-ion applications, this problem is solved via air or liquid heating and cooling systems that may need occasional maintenance throughout their service life. CES requires a maintenance-free thermal management system providing protection from environmental conditions while rejecting heat from a moderate electrical duty cycle. Thus, the development of an effective, low-cost, zero-maintenance thermal management system poses a challenge critical to the success of CES. NREL and Southern California Edison have collaborated to evaluate the long-term effectiveness of various CES thermal configurations in multiple climates by building a model of CES based on collected test data, integrating it with an NREL-developed Li-ion degradation model, and applying CES electrical duty cycles and historic location-specific meteorological data to forecast battery thermal response and degradation through a 10-year service life.

25 ENERGY STORAGE↗

Containerization in ATLAS Software Development and Data Production

The ATLAS experiment's software production and distribution on the grid benefits from a semi-automated infrastructure that provides up-to-date information about software usability and availability through the CVMFS dis-tribution service for all relevant systems. The software development process uses a Continuous Integration pipeline involving testing, validation, packag-ing and installation steps. For opportunistic sites that can not access CVMFS, containerized releases are needed. These standalone containers are currently created manually to support Monte-Carlo data production at such sites. In this paper we will describe an automated procedure for the containerization of AT-LAS software releases in the existing software development infrastructure, its motivation, integration and testing in the distributed computing system.

97 MATHEMATICS AND COMPUTING↗

Enabling Realistic Communications Evaluations for ADMS

Increasing penetration levels of inverter-based distributed energy resources (DERs) in distribution systems are creating challenges in system operation. Currently, wired or proprietary wireless communications are used by advanced distribution management systems (ADMS) to detect the state of the system and control the DERs for optimal operation. Wireless communications are an alternative solution that can enable connectivity between the dispersed assets used in distribution system applications. As demand for the seamless integration of distributed energy resources (DERs) continues to increase, proper networking and communications systems are becoming important to support the DER infrastructure. This report summarizes validation of a private wireless LTE network in a laboratory environment. The purpose of this work is to 1) demonstrate the effectiveness of private wireless LTE communication for grid applications and 2) provide a means of evaluating latency and overall performance of wireless communication in grid applications. First, private wireless LTE communication was validated in a direct transfer trip relaying scenario as an example of one-way communications using grid equipment. This study provided a baseline understanding of the variation in latency for seven different kinds of wireless scenarios shown in Figure A below. As expected, weak (attenuated) wireless signal-based communication yielded the widest ranges in latency. When higher priority was set for the trip signal communication, this resulted in lower latency in communication timing. In the final phase of this project, the private wireless LTE network was validated using two-way communications in an advanced distribution management system (ADMS) testbed which was developed in the ESIF at NREL. The purpose of this was to study the impact of wireless communication on grid performance.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Computational Aeroelastic Analysis of Ares Crew Launch Vehicle Bi-Modal Loading

A Reynolds averaged Navier-Stokes analysis, with and without dynamic aeroelastic effects, is presented for the Ares I-X launch vehicle at transonic Mach numbers and flight Reynolds numbers for two grid resolutions and two angles of attack. The purpose of the study is to quantify the force and moment increment imparted by the sudden transition from fully separated flow around the crew module - service module junction to that of the bi-modal flow state in which only part of the flow reattaches. The bi-modal flow phenomenon is of interest to the guidance, navigation and control community because it causes a discontinuous jump in forces and moments. Computations with a rigid structure at zero zero angle of attack indicate significant increases in normal force and pitching moment. Dynamic aeroelastic computations indicate the bi-modal flow state is insensitive to vehicle flexibility due to the resulting deflections imparting only very small changes in local angle of attack. At an angle of attack of 2.5deg, the magnitude of the pitching moment increment resulting from the bi-modal state nearly triples, while occurring at a slightly lower Mach number. Significant grid induced variations between the solutions indicate that further grid refinement is warranted.

Massey, Steven J.↗

On the Path to Energy Independence and a Clean Power Future – LED Lighting Retrofit and Solar Power Generation for the CTUIR Science and Engineering Laboratory and Public Transit Center (Rev.1)

This project supports the goals of the Energy Policy for the Confederated Tribes of the Umatilla Indian Reservation (CTUIR) through the implementation of an energy efficiency measure (LED lighting retrofit) and construction of a fixed rack (stationary) ground-mounted solar photovoltaic (PV) array energy generation system. The project objective was to eliminate the net demand for grid-based utility energy at two tribal facilities: the CTUIR Field Station and the Public Transit Center (consisting of bus barn and maintenance shop buildings). A total of 332 lighting fixtures were retrofitted with high efficiency LEDs at the three buildings within the project scope. The solar PV array constructed adjacent to the Field Station (46330 Timine Way, Pendleton, OR 97801) has a nameplate capacity of 97.98 kW DC . The project was managed by staff from the CTUIR Energy & Environmental Sciences Program within the Department of Natural Resources and the final budget was $\$ $288,206. Data was collected during a 12 month monitoring period following construction of the aptly named Ántukš–Tín̓qapapt Solar PV Array and assessed to determine project results. During this time, the solar PV system generated 125,580 kWh of energy according to SolrenView solar PV system monitoring service. In contrast, the total realized utility energy and cost savings due to the project were estimated by comparing 24 months of consecutive utility billing data. Results of this comparison indicate that grid-based utility energy demand was reduced by 121,280 kWh, or roughly 80% of the total electricity consumed by both facilities. The cost savings associated with this energy demand reduction were $\$ $11,104 and a payback period of 5.7 years was estimated for recovering the CTUIR’s investment. However, it should be noted that these figures are not representative of the savings that could be obtained under normal, error-free (i.e. faultless) conditions. Several undesirable events occurred during the 12 month monitoring and evaluation period, the effects of which were quantified using available data so that results under a “Faultless Scenario” could be estimated. Annual energy and cost savings estimated for the Faultless Scenario were approximately 166,289 kWh and $\$ $15,225, respectively. These figures should prove to be more representative of the long-term average annual results achieved in response to the project and suggest a payback period closer to 4.5 years for the CTUIR.

14 SOLAR ENERGY↗

Cayuga County Regional Digester: Vision Becomes Reality. Final Report

With an average herd size of 113 mature cows, Cayuga County is home to 280 dairy farms and 31,500 dairy milking cows producing approximately 855 million gallons of milk per year. The Cayuga Dairy industry is a major contributor to the countys economy, employing nearly 1200 people, while generating $140,000,000 of revenue from sale of milk alone. At the same time, the Cayuga County dairy industry also produces 5.7 million gallons of manure daily: (a) Nearly 34% of this manure is produced on smaller farms. (b) Digesters are expensive pieces of equipment and require attention and care. ( c) The on-farm digester systems have fairly long payback (>10 years) even for larger CAFO farms (>1000 milking cows). In 2005, Cayuga County Soil and Water Conservation District (The District), a Public Agency under Cayuga County, decided to undertake a centralized community digester project. The primary goal of the project was to develop an economically sustainable model, under the auspices of The District to address manure management issues facing the smaller dairies, improve the water quality and improve the quality of life for Cayuga County residents. It is believed that the District has accomplished this goal by completing construction of Cayuga County Regional Digester on a parcel of land behind the Cayuga County Natural Resource Center located at 7413 County House Road in the Town of Sennett in Cayuga County, New York. The digester facility consists of the following major components. 1. Transfer Station: This an indoor truck bay, where 35,000 gallons of manure from three local farms, 8,500 gallons of liquid organic food-processor waste, and 1,200 gallons of brown grease are unloaded from tanker trucks and the digested slurry is loaded onto the tanker trucks for delivery back to the participating farms. 2. Anaerobic Digester: The project utilizes a hydraulic mix anaerobic digester, a unique design that has no internal moving parts for mixing. The digester, which operates at mesophilic temperatures, is designed to process the daily feedstock and produce 220,000 SCF2 of biogas per day. The digester also produces 44,000 gallons of digested slurry per day. 3. Biogas Conditioning System: The plant employs a biological biogas conditioning system to remove the H2S and moisture contents of the biogas and prepare it to be used by the plant generation system. 4. Combined Heat and Power System (CHP): This is a 633kW high efficiency biogas-fired GE-Jenbacher model JMS-312 GS-NL reciprocating engine cogeneration system. The heat recovery system incorporated into the package is designed to capture the waste heat from the engine exhaust, the jacket cooling water and the engine oil circuit. 5. Electrical Substation and Power Distribution Systems: An electrical distribution system has been constructed on-site that aggregates the electrical service of the different county buildings on the District campus into a county owned electric distribution system that is interconnected with the CHP and the local electric grid. The electrical system is designed, in accordance with the utility guidelines, to allow grid-parallel operation of CHP and provide for import and export of electric power. 6. Thermal Energy Distribution System: The heat recovery system has been integrated into a high temperature water distribution system that distributes the heat to the thermal circuits for the anaerobic digester facility. Additional piping has also been installed to transfer the remaining thermal energy to other county buildings on the campus. On a daily basis, the plant will co-process 35,000 gallons of manure from local dairy farms, 8,500 gallons of food-processor waste and 1,200 gallons of brown grease to produce 200,000 ft3/d of biogas and 44,000 gallons of pathogen-free nutrient-rich digested slurry for agricultural use by farms and in the local area.The biogas fueled CHP produces 5,157,000 kWh of electricity and 19,506 dekatherms of thermal energy per year. Electrical power generated by the cogeneration system powers all the buildings on the Cayuga County campus and any surplus power is exported to the grid under a power purchase agreement. Heat recovered from the cogeneration system will be used to maintain the temperature of the process equipment and the excess will be transported to the Cayuga County Public Safety Building to offset purchase of fossil fuel to fuel the boilers. The majority of plant operations are unmanned and automated. However, the plant will have a small staff of well-trained personnel to coordinate the feedstock deliveries and shipments, supervise the day-to-day operation, monitor the systems and perform maintenance, maintain a safe and reliable operation and to respond to emergencies.

09 BIOMASS FUELS↗

Process modifications for improved carbon fiber composites: Alleviation of the electrical hazards problem

Attempts to alleviate carbon-fiber-composite electrical hazards during airplane crash fires through fiber gasification are described. Thermogravimetric and differential scanning calorimetric experiments found several catalysts that caused fibers to combust when composites were exposed to test fires. Composites were tested in the 'Burn-Bang' apparatus and in high voltage electrical detection grid apparatus. In a standard three minute burn test modified composites released no fibers, while state-of-the-art composites released several hundred fiber fragments. Expected service life with and without catalytic modification was studied and electron microscopy and X-ray microanalysis furnished physical appearance and chemical composition data. An acrylic acid polymer fiber coating was developed that wet the carbon fiber surface uniformly with the catalyst, providing a marked contrast with the uneven coats obtained by solution-dipping.

Ramohalli, K.↗

Challenges in Obtaining and Visualizing Satellite Level 2 Data in GIS

Satellite data products are important for a wide variety of applications that can bring far-reaching benefits to the science community and the broader society. These benefits can best be achieved if the satellite data are well utilized and interpreted. Unfortunately, this is not always the case, despite the abundance and relative maturity of numerous satellite data products provided by NASA and other organizations. One way to help users better understand the satellite data is to provide data along with Images, including accurate pixel coverage area delineation, and science team recommended quality screening for individual geophysical parameters. However, there are challenges of visualizing remote sensed non-gridded products: (1) different geodetics of space-borne instruments (2) data often arranged in a long-track and a cross-track axes (3) spatially and temporally continuous data chunked into granule files: data for a portion (or all) of a satellite orbit (4) no general rule of resampling or interpolations to a grid (5) geophysical retrieval only based on pixel center location without shape information. In this presentation, we will unravel a new Goddard Earth Sciences Data and Information Services Center (GES DISC) Level 2 (L2) visualization on-demand service. The service's front end provides various visualization and data accessing capabilities, such as overlay and swipe of multiply variables and subset and download of data in different formats. The backend of the service consists of Open Geospatial Consortium (OGC) standard-compliant Web Mapping Service (WMS) and Web Coverage Service. The infrastructure allows inclusion of outside data sources served in OGC compliant protocols and allows other interoperable clients, such as ArcGIS clients, to connect to our L2 WCS/WMS.

GI↗