Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Germanium”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,351 records · Page 75

Charge trapping correction and energy performance of the Majorana Demonstrator

P-type point contact (PPC) high-purity germanium detectors are an important technology in astroparticle and nuclear physics due to their superb energy resolution, low noise, and pulse shape discrimination capabilities. Analysis of data from the Majorana Demonstrator, a neutrinoless double-β decay experiment deploying PPC detectors enriched in 76 Ge, has led to several novel improvements in the analysis of PPC signals. Here, in this work we discuss charge trapping in PPC detectors and its effect on energy resolution. Small dislocations or impurities in the crystal lattice result in trapping of charge carriers from an ionization event of interest, attenuating the signal, and degrading the measured energy. We present a modified digital pole-zero correction to the signal energy estimation that counters the effects of charge trapping and improves the energy resolution of the Majorana Demonstrator by approximately 30 % to around 2.4 keV full width at half-maximum at 2039 keV, the 76 Ge Q value. An alternative approach achieving similar resolution enhancement is also presented.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Double-electron capture on {sup 112}Sn to the excited 1871 keV state in {sup 112}Cd: A possible alternative to double-{beta} decay

We report the first use of a coincidence technique to study neutrinoless double-electron capture (0{nu}ECEC) to an excited state in the daughter nucleus. We investigated 0{nu}ECEC by {sup 112}Sn leading to the possibly degenerate 1871 keV excited state in {sup 112}Cd by searching for its deexcitation {gamma} rays of 1253 keV and 618 keV in coincidence. The experiment was performed at ground level. A sample of 3.91 g of tin enriched to 99.5% in {sup 112}Sn was placed between two high-purity germanium {gamma}-ray detectors. In order to enhance the sample material, rods of natural tin totaling 1.2 kg (natural abundance 0.97%{sup 112}Sn) surrounded the cylindrical surface of our two {gamma}-ray detectors. After an exposure of 1.59 kg x days of {sup 112}Sn, no decays were observed. From this null result we determine a lower limit for the half-life time of T{sub 1/2}>2.7(1.3)x10{sup 19} yr (68%(90%) CL). We hope to achieve a sensitivity in the 10{sup 23} to 10{sup 24} yr range with a sample of a few kg of {sup 112}Sn and improved {gamma}-ray detectors in an underground facility.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Isomeric states in neutron-deficient A{approx}80-90 nuclei populated in the fragmentation of {sup 107}Ag

The relativistic projectile fragmentation of a 750 MeV per nucleon beam of {sup 107}Ag was used to populate isomeric states in neutron-deficient nuclei around A=80-90. Reaction products were separated and unambiguously identified using the GSI FRagment Separator (FRS) and its ancillary detectors. At the final focal plane, the fragments were slowed from relativistic energies by means of an aluminium degrader and implanted in a passive stopper in the center of the high-efficiency, high-granularity Stopped Rare Isotope Spectroscopic INvestigation at GSI (RISING) germanium array. This allowed the identification of excited states in the N=Z nuclei {sub 43}{sup 86}Tc and, for the first time, {sub 41}{sup 82}Nb. Isomeric states have also been identified for the first time in {sup 87,88}Tc, and a previously unreported isomer was observed in {sup 84}Nb. Experimental results are presented along with a discussion on the structure of these nuclei based on interpretations provided by several theoretical models.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Monolithically Integrated $\varepsilon$-Ge/In x Ga 1-x As Quantum Well Laser Design: Experimental and Theoretical Investigation

Here, we have analyzed the electrical and optical phenomenon occurring in a $\varepsilon$-Ge/In x Ga 1-x -Ge/In x Ga 1-x As quantum well (QW) laser through self-consistent physical solvers calibrated using in-house experimental results. A separate confinement heterostructure QW design is proposed to enable lasing from tensile strained germanium ($\varepsilon$-Ge/In x Ga 1-x -Ge) in the range of 1.55 um to 4 um wavelengths as a function of QW thickness and indium (In) composition. Different recombination mechanisms were analyzed as a function of tensile strain in $\varepsilon$-Ge/In x Ga 1-x -Ge QW. Minority carrier lifetime and band alignment are key attributes of a QW laser, which were measured using microwave photoconductive decay and x-ray photoelectron spectroscopy (as a function of In composition), respectively. The transition point of Ge to a direct bandgap material is re-affirmed to be at $\varepsilon$-Ge/In x Ga 1-x = 1.6% (In ~24%) and the transition from type I to type II for $\varepsilon$-Ge/In x Ga 1-x -Ge/In x Ga 1-x As QW is found to be at In ~55%. Also, the transition to a TM mode dominant laser is identified at In ~15%. Using a tunable waveguide design to optimize confinement as a function of In composition, strain, wavelength, QW thickness, refractive index, and geometry, the $\varepsilon$-Ge/In x Ga 1-x -Ge QW laser design provided a net material gain of ~2000 cm -1 and a threshold current density of ~5 kA/cm 2 , which is an improvement over existing Ge based lasers. In conclusion, the impact of In composition and QW thickness on the band structure, polarized gain spectra, and various lasing metrics were analyzed to show $\varepsilon$-Ge/In x Ga 1-x -Ge/InGaAs QW lasers as promising for integrated photonics.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Phenomenological Model for Predicting the Energy Resolution of Neutron-Damaged Coaxial HPGe Detectors

The peak energy resolution of germanium detectors deteriorates with increasing neutron fluence. This is due to hole capture at neutron-created defects in the crystal which prevents the full energy of the gamma-ray from being recorded by the detector. A phenomenological model of coaxial HPGe detectors is developed that relies on a single, dimensionless parameter that is related to the probability for immediate trapping of a mobile hole in the damaged crystal. As this trap parameter is independent of detector dimensions and type, the model is useful for predicting energy resolution as a function of neutron fluence.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Plasmon-enhanced photocurrent of Ge-doped InGaO thin film transistors using silver nanoparticles

Germanium-doped indium-gallium oxide (GIGO) thin film transistors (TFTs) decorated with silver (Ag) nanoparticles (NPs) were prepared to study the plasmon effect. GIGO films of various thicknesses were deposited on SiO{sub 2}/Si substrates, and Ag NPs (∼25 nm in diameter) were formed using a thermal evaporator and a postannealing process. The Ag NPs effectively absorbed light in the wavelength range of 500 and 600 nm, which corresponds to the plasmonic effect. Due to the plasmon resonance of Ag NPs, a significantly enhanced photocurrent was observed on the devices. The current increased by 348% with exposure to light when the Ag NPs were formed at the interface between the 10-nm-thick GIGO film and SiO{sub 2} substrate. The increased photocurrent revealed the presence of strong coupling between the localized plasmon and electrical carrier of the devices. The results show that the photocurrent of GIGO TFTs can be greatly enhanced when the plasmonic Ag NPs are located in the channel region of the devices.

36 MATERIALS SCIENCE↗

SU-E-J-121: Measuring Prompt Gamma Emission Profiles with a Multi-Stage Compton Camera During Proton Beam Irradiation: Initial Studies

Purpose: Recent studies have suggested that the characteristics of prompt gammas (PG) emitted during proton beam irradiation are advantageous for determining beam range during treatment delivery. The purpose of this work was to determine the feasibility of determining the proton beam range from PG data measured with a prototype Compton camera (CC) during proton beam irradiation. Methods: Using a prototype multi-stage CC the PG emission from a water phantom was measured during irradiation with clinical proton therapy beams. The measured PG emission data was used to reconstruct an image of the PG emission using a backprojection reconstruction algorithm. One dimensional (1D) profiles extracted from the PG images were compared to: 1) PG emission data measured at fixed depths using collimated high purity Germanium and Lanthanum Bromide detectors, and 2) the measured depth dose profiles of the proton beams. Results: Comparisons showed that the PG emission profiles reconstructed from CC measurements agreed very well with the measurements of PG emission as a function of depth made with the collimated detectors. The distal falloff of the measured PG profile was between 1 mm to 4 mm proximal to the distal edge of the Bragg peak for proton beam ranges from 4 cm to 16 cm in water. Doses of at least 5 Gy were needed for the CC to measure sufficient data to image the PG profile and localize the distal PG falloff. Conclusion: Initial tests of a prototype CC for imaging PG emission during proton beam irradiation indicated that measurement and reconstruction of the PG profile was possible. However, due to limitations of the operational parameters (energy range and count rate) of the current CC prototype, doses of greater than a typical treatment dose (∼2 Gy) were needed to measure adequate PG signal to reconstruct viable images. Funding support for this project provided by a grant from DoD.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

TU-AB-201-09: Calibration of An Element of a New Directional Pd-103 Planar Source Array

Purpose: The CivaSheet™ is a new directional Pd-103 planar source array, with a variable number of discrete source elements referred to as “dots”. Each dot consists of a polymer capsule containing {sup 103}Pd and a gold shield that attenuates radiation on one side of the device to define hot and cold dose regions. Fluorescence from the gold shield is observed in the dot spectrum. Since CivaSheet™ is a planar directional source, conventional methods used for calibration of azimuthally symmetric sources are not applicable. The purpose of this work is to establish an air-kerma-strength standard and a transfer to a well chamber for clinical calibration. Methods: Primary air-kerma strength measurement of the dots was performed using a variable-aperture free-air chamber (VAFAC). Charge measurements were recorded using a well chamber with a custom insert. Anisotropy measurements were performed using a Sodium-Iodide detector. Spectral measurements were performed using a low-energy germanium detector and compared to a source without gold. The dot geometry was modeled using the MCNP6 radiation transport code. Results: Air-kerma strength measurements of a batch of four dots performed with the VAFAC were within ±1.5% of the average measured value and the measurement precision was within ±0.5%. Anisotropy measurements indicated uniform emission within the measurement uncertainty for the solid angle defining the VAFAC aperture used. Charge measurements of each dot using the well chamber in four cardinal angle source orientations were within ±1.5% of the average measured values. The spectral study of a dot resulted in identification of fluorescence from the gold shield and primary spectral energies that were compared to MCNP6 simulations. Conclusion: Calibration procedures for the new directional Pd-103 source dot were established for future clinical use, based on the results of experimental and Monte Carlo investigations. This work was partially supported by NCI contract (HHSN261201200052C) through CivaTech Oncology Inc.

60 APPLIED LIFE SCIENCES↗

Air-kerma strength determination of a new directional {sup 103}Pd source

Purpose: A new directional {sup 103}Pd planar source array called a CivaSheet™ has been developed by CivaTech Oncology, Inc., for potential use in low-dose-rate (LDR) brachytherapy treatments. The array consists of multiple individual polymer capsules called CivaDots, containing {sup 103}Pd and a gold shield that attenuates the radiation on one side, thus defining a hot and cold side. This novel source requires new methods to establish a source strength metric. The presence of gold material in such close proximity to the active {sup 103}Pd region causes the source spectrum to be significantly different than the energy spectra of seeds normally used in LDR brachytherapy treatments. In this investigation, the authors perform air-kerma strength (S{sub K}) measurements, develop new correction factors for these measurements based on an experimentally verified energy spectrum, and test the robustness of transferring S{sub K} to a well-type ionization chamber. Methods: S{sub K} measurements were performed with the variable-aperture free-air chamber (VAFAC) at the University of Wisconsin Medical Radiation Research Center. Subsequent measurements were then performed in a well-type ionization chamber. To realize the quantity S{sub K} from a directional source with gold material present, new methods and correction factors were considered. Updated correction factors were calculated using the MCNP 6 Monte Carlo code in order to determine S{sub K} with the presence of gold fluorescent energy lines. In addition to S{sub K} measurements, a low-energy high-purity germanium (HPGe) detector was used to experimentally verify the calculated spectrum, a sodium iodide (NaI) scintillating counter was used to verify the azimuthal and polar anisotropy, and a well-type ionization chamber was used to test the feasibility of disseminating S{sub K} values for a directional source within a cylindrically symmetric measurement volume. Results: The UW VAFAC was successfully used to measure the S{sub K} of four CivaDots with reproducibilities within 0.3%. Monte Carlo methods were used to calculate the UW VAFAC correction factors and the calculated spectrum emitted from a CivaDot was experimentally verified with HPGe detector measurements. The well-type ionization chamber showed minimal variation in response (<1.5%) as a function of source positioning angle, indicating that an American Association of Physicists in Medicine (AAPM) Accredited Dosimetry Calibration Laboratory calibrated well chamber would be a suitable device to transfer an S{sub K}-based calibration to a clinical user. S{sub K} per well-chamber ionization current ratios were consistent among the four dots measured. Additionally, the measurements and predictions of anisotropy show uniform emission within the solid angle of the VAFAC, which demonstrates the robustness of the S{sub K} measurement approach. Conclusions: This characterization of a new {sup 103}Pd directional brachytherapy source helps to establish calibration methods that could ultimately be used in the well-established AAPM Task Group 43 formalism. Monte Carlo methods accurately predict the changes in the energy spectrum caused by the fluorescent x-rays produced in the gold shield.

07 ISOTOPE AND RADIATION SOURCES↗

Features of light attenuation in crystals under violation of the Bouguer law

A computer simulation and measurements of the light transmittance of germanium and paratellurite crystals of different thickness were used to show that, at scattering probabilities of photons comparable to their absorption probabilities, the standard methods for calculating light extinction coefficients on the basis of the Bouguer law lead to rough errors in estimation of the optical quality of a material.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Melt nonstoichiometry and defect structure of ZnGeP{sub 2} crystals

The defect structure of ZnGeP{sub 2} crystals grown from a melt by the vertical Bridgman method has been investigated. A deviation of the melt composition from stoichiometric leads to the formation of striations and the inclusions of other phases which are observed as structures (chains) oriented parallel to the growth axis. According to the microanalysis data, the inclusion composition corresponds to a mixture of ZnGeP{sub 2}, Zn{sub 3}P{sub 2}, and Ge. Nanoinclusions of germanium phosphide are detected by transmission electron microscopy. X-ray topography reveals defects of four types. The main defects in the central part of an ingot are related to the composition fluctuations, and the newly formed dislocations are basically single ones. Most dislocations are formed at the crystal periphery.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

X-ray imaging of structural defects in Si{sub 1-x}Ge{sub x} single crystals using a white synchrotron beam

Nonmonochromatic (white) synchrotron radiation with a high spatial coherence makes it possible to use different types of interaction of X-rays with matter simultaneously: diffraction, refraction, absorption, and fluorescence. In this case, the structure of materials is studied by the real-time recording of high-resolution images of different types under the same conditions. The use of X-ray images for studying the structural quality is demonstrated by the example of Czochralski-grown Si{sub 1-x}Ge{sub x} single crystals. The effect that the germanium content has on the formation and evolution of the defect structure is analyzed and the relationship between the structure and properties is investigated. The experiments were performed on the Pohang Light Source (Pohang, Republic of Korea).

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Evaluation of the neutron background in an HPGe target for WIMP direct detection when using a reactor neutrino detector as a neutron veto system

A direct WIMP (weakly interacting massive particle) detector with a neutron veto system is designed to better reject neutrons. The experimental configuration is studied in this paper involves 984 Ge modules placed inside a reactor-neutrino detector. The neutrino detector is used as a neutron veto device. The neutron background for the experimental design is estimated using the Geant4 simulation. The results show that the neutron background can decrease to O(0.01) events per year per tonne of high-purity germanium and it can be ignored in comparison with electron recoils.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Process of negative-muon-induced formation of an ionized acceptor center ({sub μ}A){sup –} in crystals with the diamond structure

The formation of an ionized acceptor center by a negative muon in crystals with the diamond structure is considered. The negative muon entering a target is captured by a nucleus, forming a muonic atom {sub μ}A coupled to a lattice. The appearing radiation-induced defect has a significant electric dipole moment because of the violation of the local symmetry of the lattice and changes the phonon spectrum of the crystal. The ionized acceptor center is formed owing to the capture of an electron interacting with the electric dipole moment of the defect and with the radiation of a deformation-induced local-mode phonon. Upper and lower bounds of the formation rate of the ionized acceptor center in diamond, silicon, and germanium crystals are estimated. It is shown that the kinetics of the formation of the acceptor center should be taken into account when processing μSR experimental data.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Magnification Effects in Scanning Tunneling Microscopy: the Role of Surface Radicals

Scanning tunneling microscopy (STM) is a fundamental tool for determination of the surface atomic structure. However, the interpretation of high resolution microscopy images is not straightforward. In this paper we provide a physical insight on how STM images can suggest atomic locations which are distinctively different from the real ones. This effect should be taken into account when interpreting high-resolution STM images obtained on surfaces with directional bonds. It is shown that spurious images are formed in the presence of polarized surface radicals showing a pronounced angle with respect to the surface normal. This issue has been overlooked within the surface science community and often disregarded by experimentalists working with STM. Without loss of generality, we illustrate this effect by the magnification observed for pentamer-like structures on (110), (113), and (331) surfaces of silicon and germanium.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Quantum Isotope Effect in Silicon at Low Temperatures

High-precision studies of Raman scattering in isotopically pure {sup 28}Si, {sup 29}Si, {sup 30}Si single crystals have been performed in the temperature range from 8 to 300 K. It has been found that a difference of about (0.4 ± 0.1) cm{sup –1} observed at temperatures T ≤ 100 K between the normalized Raman frequencies of the {sup 28}Si and {sup 30}Si isotopes measured with an accuracy of 0.1 cm{sup –1} is certainly due to quantum effects damping with increasing temperature. The possibility of observing quantum isotope effects in germanium has been estimated using experimental data on isotope effects in diamond and silicon.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Ferromagnetism in diluted Pb{sub 1-x-y}Ge{sub x}Cr{sub y}Te magnetic semiconductors

Magnetic properties of Pb{sub 1-x-y}Ge{sub x}Cr{sub y} Te alloys (x = 0.02-0.20, y = 0.01-0.08) were studied. It was detected that the magnetic susceptibility of alloys consists of two contributions: the paramagnetic Curie-Weiss part (the temperature region is T < 50 K) caused, probably, by the Cr{sup 3+} ion paramagnetism, and the high-temperature ferromagnetic part (T < 300 K). The dependences of the concentration of magnetic centers on the composition of the matrix were obtained from the paramagnetic and ferromagnetic contributions. It was shown that a decrease in the concentration of paramagnetic centers can be, at least qualitatively, explained by the transformation of the electronic structure as the germanium concentration increases. A phenomenological model was suggested, which explains the behavior of magnetic properties as the chromium content increases, and possible mechanisms of ferromagnetic ordering in studied alloys are discussed.

36 MATERIALS SCIENCE↗

Optical properties of silicon with a high content of boron

After exposure of silicon with a high content of boron and oxygen to light with the spectrum close to that of solar radiation and with the intensity 70-80 mW cm{sup -2}, a new defect corresponding to the absorption band observed at liquid-helium temperature at the frequency 1026.7 cm{sup -1} is detected in the material. It is shown that the components of the defect are boron and oxygen atoms. The defect is formed at a considerable concentration of free charge carriers induced by exposure of the sample to light or by heat treatments at a low current flow through the sample. It is thought that the defect can be formed due to the direct interaction between the components as well as via the precursors of the stable form of the defect. It is shown that doping of silicon with germanium reduces the efficiency of the formation of the defect corresponding to the detected absorption band.

36 MATERIALS SCIENCE↗