Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “GAS CHROMATOGRAPHY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,351 records · Page 75

Exploiting the Semidestructive Nature of Gas Cluster Ion Beam Time-of-Flight Secondary Ion Mass Spectrometry Imaging for Simultaneous Localization and Confident Lipid Annotations

Lipids have been considered as key players in cell signaling and disease. Information on their location and distribution within a biological system, under varying conditions, is necessary to understand the contributions of different lipid species to an altered phenotype. Imaging mass spectrometry techniques, such as time-of-flight secondary ion mass spectrometry (ToF-SIMS) and matrix-assisted laser desorption/ionization (MALDI), are capable of revealing global lipid distributions in tissues in an untargeted fashion. Yet, to confidently identify the species present in a sample, orthogonal analyses like tandem MS (MS/MS) are often required. This can be accomplished by bulk sample analysis with liquid chromatography (LC)-MS/MS, which can provide confident lipid identifications, at the expense of losing location-specific information. Here, using planarian flatworms as a model system, we demonstrate that imaging gas cluster ion beam (GCIB)-ToF-SIMS has the unique capability to simultaneously detect, identify, and image lipid species with subcellular resolution in tissue sections. The parallel detection of both, intact lipids and their respective fragments, allows for unique identification of some species without the need of performing an additional orthogonal MS/MS analysis. This was accomplished by correlating intact lipid and associated fragment SIMS images. The lipid assignments, respective fragment identities, and locations gathered from ToF-SIMS data were confirmed via LC-MS/MS on lipid extracts and ultrahigh mass resolution MALDI-MS imaging. Together, these data show that the semidestructive nature of ToF-SIMS can be utilized advantageously to enable both confident molecular annotations and to determine the locations of species within a biological sample.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Size Exclusion Chromatography-Ion Mobility-Mass Spectrometry Coupling: a Step Toward Structural Biology

Noncovalent interactions are essential for the structural organization of biomacromolecules in cells. For this reason, the study of the biophysical, dynamic, and architectural interactions among biomacromolecules is essential. Since mass spectrometry requires compatible solutions while preserving the noncovalent bonding network, we envisioned that size exclusion chromatography coupled with ion mobility and mass spectrometry would be a valuable technique to desalt the initial sample and provide solution and gas-phase structural information in a single stage experiment. Such coupling allowed obtaining information on solution protein complex composition with SEC separation and on authenticity and purity with IMS-MS. Our study demonstrated that such coupling is compatible, useful, as well as suitable for a routine analysis, in pharmaceutical industry, for example. Mobility data were reliable and injected standards allowed calibrating the collision cross-section scale. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Degradation and crosslinking of perfluoroalkyl polyethers under X-ray irradiation in ultrahigh vacuum

Degradation of three types of commercially available perfluoroalkyl polyethers (PFPE)-Demnum S200, Fomblin Z25, and Krytox 16256-by X-ray irradiation was studied by using X-ray photoemission spectroscopy (XPS) and a mass spectrometer under ultra-high-vacuum conditions. The carbons in the polymers were characterized by chemical shifts of Cls binding energies. Gaseous products containing COF2 and low-molecular-weight fluorocarbons were formed. From Fomblin Z25, which has acetal linkages (-OCF2O-), a large quantity of COF2 gas was evolved. Liquid products became tacky after a long irradiation time, and some did not dissolve in Freon. High-pressure liquid chromatography (HPLC) showed that molecular weight distribution became broader and that higher molecular weight polymers were formed from Demnum and Krytox. We concluded from these results that degradation and cross-linking took place simultaneously. Demnum crosslinked more easily than the other fluids. The time dependence of both XPS spectra of Cls and mass spectra showed that C-O-bonded carbons in PFPE'S were removed faster than other carbons. There was no substrate effect on the degradation reaction because the first-order rate constants calculated from the change of gaseous products were similar when stainless steel (440C) and gold-coated surfaces were used. Metal fluorides were formed on stainless steel during the reaction. A mechanism for the degradation of PFPE'S is discussed on the basis of their molecular structures.

Mori, Shigeyuki↗

Sample contamination with NMP-oxidation products and byproduct-free NMP removal from sample solutions

1-Methyl-2-pyrrolidinone (NMP) is widely used as a solvent for coal-derived products and as eluent in size exclusion chromatography. It was observed that sample contamination may take place, through reactions of NMP, during extraction under refluxing conditions and during the process of NMP evaporation to concentrate or isolate samples. In this work, product distributions from experiments carried out in contact with air and under a blanket of oxygen-free nitrogen have been compared. Gas chromatography/mass spectrometry (GC-MS) clearly shows that oxidation products form when NMP is heated in the presence of air. Upon further heating, these oxidation products appear to polymerize, forming material with large molecular masses. Potentially severe levels of interference have been encountered in the size exclusion chromatography (SEC) of actual samples. Laser desorption mass spectrometry and SEC agree in showing an upper mass limit of nearly 7000 u for a residue left after distilling 'pure' NMP in contact with air. Furthermore, experiments have shown that these effects could be completely avoided by a strict exclusion of air during the refluxing and evaporation of NMP to dryness. 45 refs., 13 figs.

01 COAL, LIGNITE, AND PEAT↗

Differential Mobility Spectrometry for Improved Selectivity in Hydrophilic Interaction Liquid Chromatography-Tandem Mass Spectrometry Analysis of Paralytic Shellfish Toxins

Paralytic shellfish toxins (PSTs) are neurotoxins produced by dinoflagellates and cyanobacteria that cause paralytic shellfish poisoning in humans. PST quantitation by LC-MS is challenging because of their high polarity, lability as gas-phase ions, and large number of potentially interfering analogues. Differential mobility spectrometry (DMS) has the potential to improve the performance of LC-MS methods for PSTs in terms of selectivity and limits of detection. This work describes a comprehensive investigation of the separation of 16 regulated PSTs by DMS and the development of highly selective LC-DMS-MS methods for PST quantitation. The effects of all DMS parameters on the separation of PSTs from one another were first investigated in detail. The labile nature of 11α-gonyautoxin epimers gave unique insight into fragmentation of labile analytes before, during, and after the DMS analyzer. Two sets of DMS parameters were identified that either optimized the resolution of PSTs from one another or transmitted them at a limited number of compensation voltage (CV) values corresponding to structural subclasses. These were used to develop multidimensional LC-DMS-MS/MS methods using existing HILIC-MS/MS parameters. In both cases, improved selectivity was observed when using DMS, and the quantitative capabilities of a rapid UPLC-DMS-MS/MS method were evaluated. Limits of detection of the developed method were similar to those without DMS, and differences were highly analyte-dependant. Analysis of shellfish matrix reference materials showed good agreement with established methods. The developed methods will be useful in cases where specific matrix interferences are encountered in the LC-MS/MS analysis of PSTs in complex biological samples. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Ultrahigh-Resolution Differential Ion Mobility Separations of Conformers for Proteins above 10 kDa: Onset of Dipole Alignment?

Biomacromolecules tend to assume numerous structures in solution or the gas phase. It has been possible to resolve disparate conformational families but not unique geometries within each, and drastic peak broadening has been the bane of protein analyses by chromatography, electrophoresis, and ion mobility spectrometry (IMS). The new differential IMS (FAIMS) approach using hydrogen-rich gases was recently found to separate conformers of a small protein ubiquitin with same peak width and resolving power up to ~400 as for peptides. Present work explores the reach of this approach for larger proteins, exemplified by cytochrome c and myoglobin. Resolution similar to that for ubiquitin was largely achieved with longer separations, while the onset of peak broadening and coalescence with shorter separations suggests the limitation of present technique to proteins under ~20 kDa. This capability may enable distinguishing whole proteins with differing residue sequences or localizations of posttranslational modifications. Small features at negative compensation voltages that markedly grow from cytochrome c to myoglobin indicate the dipole alignment of rare conformers in accord with theory, further supporting the concept of pendular macroions in FAIMS.

Environmental Molecular Sciences Laboratory↗

THE ABUNDANCES OF HYDROCARBON FUNCTIONAL GROUPS IN THE INTERSTELLAR MEDIUM INFERRED FROM LABORATORY SPECTRA OF HYDROGENATED AND METHYLATED POLYCYCLIC AROMATIC HYDROCARBONS

Infrared (IR) absorption spectra of individual polycyclic aromatic hydrocarbons (PAHs) containing methyl (-CH{sub 3}), methylene (CH{sub 2}), or diamond-like CH groups and IR spectra of mixtures of methylated and hydrogenated PAHs prepared by gas-phase condensation were measured at room temperature (as grains in pellets) and at low temperature (isolated in Ne matrices). In addition, the PAH blends were subjected to an in-depth molecular structure analysis by means of high-performance liquid chromatography, nuclear magnetic resonance spectroscopy, and matrix-assisted laser desorption/ionization time-of-flight mass spectrometry. Supported by calculations at the density functional theory level, the laboratory results were applied to analyze in detail the aliphatic absorption complex of the diffuse interstellar medium at 3.4 μm and to determine the abundances of hydrocarbon functional groups. Assuming that the PAHs are mainly locked in grains, aliphatic CH {sub x} groups (x = 1, 2, 3) would contribute approximately in equal quantities to the 3.4 μm feature (N {sub CHx}/N {sub H} ≈ 10{sup –5}-2 × 10{sup –5}). The abundances, however, may be two to four times lower if a major contribution to the 3.4 μm feature comes from molecules in the gas phase. Aromatic ≅CH groups seem to be almost absent from some lines of sight, but can be nearly as abundant as each of the aliphatic components in other directions (N{sub ≅CH}/N {sub H} ∼< 2 × 10{sup –5}; upper value for grains). Due to comparatively low binding energies, astronomical IR emission sources do not display such heavy excess hydrogenation. At best, especially in protoplanetary nebulae, CH{sub 2} groups bound to aromatic molecules, i.e., excess hydrogens on the molecular periphery only, can survive the presence of a nearby star.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Progress on the Organic and Inorganic Modules of the Spacecraft Water Impurity Monitor, a Next Generation Complete Water Analysis System for Crewed Vehicles

The Spacecraft Water Impurity Monitor (SWIM) is a joint collaboration to develop an instrument platform that will perform in-flight measurements and deliver a more complete picture of water quality to decision makers. For exploration missions, returned water samples will not be an option, so spacecraft and habitats will need to be equipped with advanced water monitoring capabilities. Eventually, missions to the moon, Mars, and beyond should be equipped with analytical capabilities roughly analogous to those found in terrestrial labs. Based on what we know about current and future spacecraft environments, SWIM will seek to provide enhanced analytical capability that enables NASA to confidently send astronauts on distant missions without the possibility of returned water samples. The SWIM architecture can be broken down in an Organic Water Module (OWM) and an Inorganic Water Module (IWM), independent of each other but can be flown together if desired; an integrated system may share some commonality, e.g., single sample injection, sampling consumables, waste, etc. Each of these main modules can be broken down further into separation (if required) and detection modules. And, each separation module can be paired with one or more detection module depending on mission, spacecraft, customer needs, and size/mass/power constraints. This paper discusses the research and development progress toward the goal of a total water analysis system. For OWM, one of the analysis technologies that the SWIM team have been developing is a liquid-injection gas chromatograph mass spectrometer system; these systems are the workhorses of analytical chemistry laboratories world-wide. For IWM, the team is exploring a number of technologies ranging from traditional liquid chromatography technologies (e.g. ion chromatography, capillary electrophoresis) to flight-heritage technology such as ion-specific electrodes.

Stuart J Pensinger↗

Progress on the Organic and Inorganic Modules of the Spacecraft Water Impurity Monitor, a Next Generation Complete Water Analysis System for Crewed Vehicles

The Spacecraft Water Impurity Monitor (SWIM) is a joint collaboration to develop an instrument platform that will perform in-flight measurements and deliver a more complete picture of water quality to decision makers. For exploration missions, returned water samples will not be an option, so spacecraft and habitats will need to be equipped with advanced water monitoring capabilities. Eventually, missions to the moon, Mars, and beyond should be equipped with analytical capabilities roughly analogous to those found in terrestrial labs. Based on what we know about current and future spacecraft environments, SWIM will seek to provide enhanced analytical capability that enables NASA to confidently send astronauts on distant missions without the possibility of returned water samples. The SWIM architecture can be broken down in an Organic Water Module (OWM) and an Inorganic Water Module (IWM), independent of each other but can be flown together if desired; an integrated system may share some commonality, e.g., single sample injection, sampling consumables, waste, etc. Each of these main modules can be broken down further into separation (if required) and detection modules. And, each separation module can be paired with one or more detection module depending on mission, spacecraft, customer needs, and size/mass/power constraints. This paper discusses the research and development progress toward the goal of a total water analysis system. For OWM, one of the analysis technologies that the SWIM team have been developing is a liquid-injection gas chromatograph mass spectrometer system; these systems are the workhorses of analytical chemistry laboratories world-wide. For IWM, the team is exploring a number of technologies ranging from traditional liquid chromatography technologies (e.g. ion chromatography, capillary electrophoresis) to flight-heritage technology such as ion-specific electrodes.

Stuart J. Pensinger↗

Progress on the Organic and Inorganic Modules of the Spacecraft Water Impurity Monitor, a Next Generation Complete Water Analysis System for Crewed Vehicles

The Spacecraft Water Impurity Monitor (SWIM) is a joint collaboration to develop an instrument platform that will perform in-flight measurements and deliver a more complete picture of water quality to decision makers. For exploration missions, returned water samples will not be an option, so spacecraft and habitats will need to be equipped with advanced water monitoring capabilities. Eventually, missions to the moon, Mars, and beyond should be equipped with analytical capabilities roughly analogous to those found in terrestrial labs. Based on what we know about current and future spacecraft environments, SWIM will seek to provide enhanced analytical capability that enables NASA to confidently send astronauts on distant missions without the possibility of returned water samples. The SWIM architecture can be broken down in an Organic Water Module (OWM) and an Inorganic Water Module (IWM), independent of each other but can be flown together if desired; an integrated system may share some commonality, e.g., single sample injection, sampling consumables, waste, etc. Each of these main modules can be broken down further into separation (if required) and detection modules. And, each separation module can be paired with one or more detection module depending on mission, spacecraft, customer needs, and size/mass/power constraints. This paper discusses the research and development progress toward the goal of a total water analysis system. For OWM, one of the analysis technologies that the SWIM team have been developing is a liquid-injection gas chromatograph mass spectrometer system; these systems are the workhorses of analytical chemistry laboratories world-wide. For IWM, the team is exploring a number of technologies ranging from traditional liquid chromatography technologies (e.g. ion chromatography, capillary electrophoresis) to flight-heritage technology such as ion-specific electrodes.

Stuart J Pensinger↗

Progress on the Organic and Inorganic Modules of the Spacecraft Water Impurity Monitor, a Next Generation Complete Water Analysis System for Crewed Vehicles

The Spacecraft Water Impurity Monitor (SWIM) is a joint collaboration to develop an instrument platform that will perform in-flight measurements and deliver a more complete picture of water quality to decision makers. For exploration missions, returned water samples will not be an option, so spacecraft and habitats will need to be equipped with advanced water monitoring capabilities. Eventually, missions to the moon, Mars, and beyond should be equipped with analytical capabilities roughly analogous to those found in terrestrial labs. Based on what we know about current and future spacecraft environments, SWIM will seek to provide enhanced analytical capability that enables NASA to confidently send astronauts on distant missions without the possibility of returned water samples. The SWIM architecture can be broken down in an Organic Water Module (OWM) and an Inorganic Water Module (IWM), independent of each other but can be flown together if desired; an integrated system may share some commonality, e.g., single sample injection, sampling consumables, waste, etc. Each of these main modules can be broken down further into separation (if required) and detection modules. And, each separation module can be paired with one or more detection module depending on mission, spacecraft, customer needs, and size/mass/power constraints. This paper discusses the research and development progress toward the goal of a total water analysis system. For OWM, one of the analysis technologies that the SWIM team have been developing is a liquid-injection gas chromatograph mass spectrometer system; these systems are the workhorses of analytical chemistry laboratories world-wide. For IWM, the team is exploring a number of technologies ranging from traditional liquid chromatography technologies (e.g. ion chromatography, capillary electrophoresis) to flight-heritage technology such as ion-specific electrodes.

Stuart Pensinger↗

Stable Chlorine Isotopes and Elemental Chlorine by Thermal Ionization Mass Spectrometry and Ion Chromatography; Martian Meteorites, Carbonaceous Chondrites and Standard Rocks

Recently significantly large mass fractionation of stable chlorine isotopes has been reported for terrestrial and lunar samples [1,2]. In addition, in view of possible early solar system processes [3] and also potential perchlorate-related fluid/microbial activities on the Martian surface [4,5], a large chlorine isotopic fractionation might be expected for some types of planetary materials. Due to analytical difficulties of isotopic and elemental analyses, however, current chlorine analyses for planetary materials are controversial among different laboratories, particularly between IRMS (gas source mass spectrometry) and TIMS (Thermal Ionization Mass Spectrometry) groups [i.e. 1,6,7] for isotopic analyses, as well as between those doing pyrohydrolysis and other groups [i.e. 6,8]. Additional careful investigations of Cl isotope and elemental abundances are required to confirm real chlorine isotope and elemental variations for planetary materials. We have developed a TIMS technique combined with HF-leaching/ion chromatography at NASA JSC that is applicable to analysis of small amounts of meteoritic and planetary materials. We present here results for several standard rocks and meteorites, including Martian meteorites.

Nakamura, N.↗

Cathodic NH 4 + leaching of nitrogen impurities in CoMo thin-film electrodes in aqueous acidic solutions

Electrocatalytic reduction of dinitrogen (N 2 ) to ammonium (NH 4 + ) in acidic aqueous solutions was investigated at ambient temperature and pressure using a cobalt–molybdenum (CoMo) thin-film electrode prepared by magnetron reactive sputtering. Increased concentrations of ammonium ions (NH 4 + ) were consistently detected in the electrolyte using ion chromatography (IC) after constant-potential electrolysis at various potentials (≤-0.29 V vs. RHE). Using a newly developed analytical method based on ammonia derivatization, performing the experiments with 15 N 2 -labelled gas led however to the detection of increased 14 NH 4 + concentrations instead of 15 NH 4 + . X-ray photoelectron spectroscopic (XPS) analysis of the electrode surface revealed the presence of Mo[triple bond, length as m-dash]N and Mo–NH x species. Several contamination sources were identified that led to substantial increases in the concentration of ammonium ions, including 15 NH 3 impurities in 15 N 2 gas. The observed ammonium concentrations can be consistently ascribed to leaching of nitrogen ( 14 N) impurities incorporated in the CoMo film during the sputtering process. Therefore, researchers in the field are urged to adopt extended protocols to identify and eliminate sources of ammonia contamination and to very carefully monitor the ammonium concentrations in each experimental step.

36 MATERIALS SCIENCE↗

The Spacecraft Water Impurity Monitor, a Framework for the Next Generation Complete Water Analysis System for Crewed Vehicles Beyond the ISS

The Spacecraft Water Impurity Monitor (SWIM) is a joint collaboration to develop an instrument platform that will perform in-flight measurements and deliver a more complete picture of water quality to decision makers. Eventually, missions to the moon, Mars, and beyond will be equipped with analytical capabilities equaling those found in terrestrial labs. Based on what we know about current and future spacecraft environments, SWIM will seek to provide enhanced analytical capability that enables NASA to confidently send astronauts on distant missions without the possibility of returned water samples. This paper discusses the challenges presented by exploration requirements and the research and development progress toward the goal of a total water analysis system. For organic analysis, one of the analysis technologies that the SWIM team have been developing is a liquid-injection gas chromatograph mass spectrometer system; these systems are the workhorses of analytical chemistry laboratories world-wide. For inorganic analysis, the team is exploring a number of technologies ranging from traditional liquid chromatography technologies (e.g. ion chromatography, capillary electrophoresis) to flight-heritage technology such as ion-specific electrodes.

water monitoring↗

Oxidation of Glycolate in the Defense Waste Processing Facility (DWPF) Recycle Collection Tank - 20305

The Savannah River Site's Defense Waste Processing Facility (DWPF) operations are being upgraded with the introduction of the Nitric-Glycolic Flowsheet. Glycolic acid has been shown superior to formic acid as the reducing acid used during chemical processing. The new flowsheet improves or maintains necessary parameters such as 1) reduction of mercury, 2) adjustment of feed rheology and 3) adjustment of melter oxidation/reduction potential. Further, the potential for catalytic hydrogen generation in DWPF processing is virtually eliminated. DWPF process condensates are collected and returned to the SRS Concentration, Storage and Transfer Facilities (CSTF). The Recycle Collection Tank (RCT) collects off-gas condensate during chemical processing, vitrification, and other unit operations performed in DWPF and is the singular return vessel delivering recycle effluent back to CSTF. Each batch of recycle may contain a small amount of glycolate from chemical processing and melter off-gas condensates. To avoid potential flammability issues due to thermolysis of glycolate in the CSTF, chemical oxidation within the RCT has been investigated as an option for mitigating the transfer of glycolate. Sodium permanganate has been down-selected as the best option for oxidation of glycolate. Testing was performed using both 2-L and 22-L reactors (16,800:1 and 1,530:1 scale by volume) with non-radioactive waste simulants to approximate the expected RCT compositions. RCT simulants were evaluated at various process pH and temperature conditions. Also, RCT operations, namely the sequence of addition of corrosion inhibitors (NaOH and NaNO{sub 2}) versus a permanganate strike, were evaluated. Glycolate was introduced via a sludge simulant to mimic both expected entrainment and abnormal process foam-over conditions - the range being between 68 and 5100 mg/kg glycolate. Glycolate destruction was monitored by ion chromatography (IC). The corresponding manganese behavior was monitored in real-time using in situ ultraviolet-visible (UV-Vis) spectroscopy. RCT glycolate content can be reduced to below the IC detection limit within 90 minutes for all concentrations investigated. Ion Chromatography analysis revealed that under alkaline conditions, glycolate is primarily oxidized to oxalate with no significant formation of CO{sub 2} or carbonate, and nitrite is not oxidized to nitrate. Initially, complete oxidation of organics species and nitrite was assumed. Determination of the mechanistic chemical reaction has allowed the required amount of permanganate to be more accurately predicted and the total addition to be significantly reduced. UV-Vis measurements reveal that permanganate (Mn{sup 7+}) is reduced to manganate (Mn{sup 6+}) in the RCT. The oxidant stoichiometry is defined by using the initial permanganate to glycolate (P/G) molar ratio. At low initial glycolate concentration (68 and 140 mg/kg), the minimum required initial permanganate to glycolate (P/G) molar ratio was found to be 5-6. With high initial glycolate concentrations (5100 mg/kg) a lower (P/G) molar ratio of ∼2.5 was needed. The final portion of this effort supporting the nitric/glycolic flowsheet will be to test actual (fully radioactive) RCT samples as per the above simulant tests. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Fullerenes, fulleranes and polycyclic aromatic hydrocarbons in the Allende meteorite

In this paper, we confirm our earlier observations of fullerenes (C60 and C70) in the Allende meteorite (Becker et al., 1994a, 1995). Fullerene C60 was also detected in two separate C-rich (approximately 0.5-1.0%) dark inclusions (Heymann et al., 1987) that were hand picked from the Allende sample. The amounts of C60 detected were approximately 5 and approximately 10 ppb, respectively, which is considerably less than what was detected in the Allende 15/21 sample (approximately 100 ppb; Becker et al., 1994a, 1995). This suggests that fullerenes are heterogeneously distributed in the meteorite. In addition, we present evidence for fulleranes, (C60Hx), detected in separate samples by laser desorption (reflectron) time-of-flight (TOF) mass spectrometry (LDMS). The LDMS spectra for the Allende extracts were remarkably similar to the spectra generated for the synthetic fullerane mixtures. Several fullerane products were synthesized using a Rh catalyst (Becker et al., 1993a) and separated using high-performance liquid chromatography (HPLC). Polycyclic aromatic hydrocarbons (PAHs) were also observed ppm levels) that included benzofluoranthene and corannulene, a cup-shaped molecule that has been proposed as a precursor molecule to the formation of fullerenes in the gas phase (Pope et al., 1993).

NASA Center ARC↗

Active Control of pH in the Bioculture System Through Carbon Dioxide Control

For successful cell research, the growth culture environment must be tightly controlled. Deviance from the optimal conditions will mask the desired variable being analyzed or lead to inconstancies in the results. In standard laboratories, technology and procedures are readily available for the reliable control of variables such as temperature, pH, nutrient loading, and dissolved gases. Due to the nature of spaceflight, and the inherent constraints to engineering designs, these same elements become a challenge to maintain at stable values by both automated and manual approaches. Launch mass, volume, and power usage create significant constraints to cell culture systems; nonetheless, innovative solutions for active environmental controls are available. The acidity of the growth media cannot be measured through standard probes due to the degradation of electrodes and reliance on indicators for chromatography. Alternatively, carbon dioxide sensors are capable of monitoring the pH by leveraging the relationship between the partial pressure of carbon dioxide and carbonic acid in solution across a membrane. In microgravity cell growth systems, the gas delivery system can be used to actively maintain the media at the proper acidity by maintaining a suitable gas mixture around permeable tubing. Through this method, launch mass and volume are significantly reduced through the efficient use of the limited gas supply in orbit.

cell growth↗

Design, Synthesis, and Characterization of Polymer Precursors to Li x PON and Li x SiPON Glasses: Materials That Enable All-Solid-State Batteries (ASBs)

LiPON-like glasses that form lithium dendrite impenetrable interfaces between lithium battery components are enabling materials that may replace liquid electrolytes permitting production of all-solid-state batteries (ASBs). Unfortunately, to date, such materials are introduced only via gas-phase deposition. Furthermore, we demonstrate the design and synthesis of easily scaled, lowtemperature, low-cost, solution-processable inorganic polymers containing LiPON/LiSiPON elements. OPCl 3 and hexachlorophosphazene [Cl 2 P=N] 3 provide starting points for elaboration using MNH 2 (M = Li/Na) or (Me 3 Si)NH followed by reaction with controlled amounts of LiNH 2 to produce oligomers/polymers with molecular weights (MWs) ≈1–2 kDa characterized by multinuclear NMR, gel permeation chromatography (GPC), thermogravimetric analysis (TGA), Fourier-transform infrared (FTIR), X-ray powder diffraction (XRD), X-ray photoelectron spectroscopy (XPS), and matrix-assisted laser desorption/ ionization (MALDI)-time-of-flight (ToF) offering stabilities to 150–200 °C and ceramic yields (800 °C) of 50–60%. 7 Li NMR suggests that precursor-bound Li + dissociates easily, beneficial for electrochemical applications. XPS shows higher N/P ratios (1–3) than via gas-phase methods (<1) correlating N/P ratios, 7 Li shifts, and Li + conductivities. Li 2 SiPHN offers the highest ambient conductivity of 3 × 10 –1 mS cm –1 at 400 °C/2 h/N 2 .

36 MATERIALS SCIENCE↗