Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Fluorescence”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,351 records · Page 75

Flow method and apparatus for screening chemicals using micro x-ray fluorescence

Method and apparatus for screening chemicals using micro x-ray fluorescence. A method for screening a mixture of potential pharmaceutical chemicals for binding to at least one target binder involves flow-separating a solution of chemicals and target binders into separated components, exposing them to an x-ray excitation beam, detecting x-ray fluorescence signals from the components, and determining from the signals whether or not a binding event between a chemical and target binder has occurred.

47 OTHER INSTRUMENTATION↗

Optical imaging of non-fluorescent nanoparticle probes in live cells

Precise imaging of cellular and subcellular structures and dynamic processes in live cells is crucial for fundamental research in life sciences and in medical applications. Non-fluorescent nanoparticles are an important type of optical probe used in live-cell imaging due to their photostability, large optical cross-sections, and low toxicity. Here, we provide an overview of recent developments in the optical imaging of non-fluorescent nanoparticle probes in live cells.

47 OTHER INSTRUMENTATION↗

A flexible setup for angle-resolved X-ray fluorescence spectrometry with laboratory sources

X-ray fluorescence (XRF) analysis is one of the standard tools for the analysis of stratified materials and is widely applied for the investigation of electronics and coatings. The composition and thickness of the layers can be determined quantitatively and non-destructively. Recent work showed that these capabilities can be extended towards retrieving stratigraphic information like concentration depth profiles using angle-resolved XRF (ARXRF). This paper introduces an experimental sample chamber which was developed as a multi-purpose tool enabling different measurement geometries suited for transmission measurements, conventional XRF, ARXRF, etc. The chamber was specifically designed for attaching all kinds of laboratory X-ray sources for the soft and hard X-ray ranges as well as various detection systems. In detail, a setup for ARXRF using an X-ray tube with a polycapillary X-ray lens as source is presented. For such a type of setup, both the spectral and lateral characterizations of the radiation field are crucial for quantitative ARXRF measurements. The characterization is validated with the help of a stratified validation sample.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fluorescence Microscopic Investigations of Molecular Dynamics in Self–Assembled Nanostructures

Many analytical methods employ self-assembled nanostructured materials as chemical recognition media. Molecular permeation through these materials exhibits unique selectivity owing to nanoconfinement-induced enhancement of permeant–nanostructure interactions. This Personal Account introduces our efforts to investigate the detailed dynamics of single or a small number of molecules in nanostructured materials. Here, we developed new experimental and analysis approaches built upon laser-based fluorescence microscopy to measure the detailed translational and orientational dynamics of molecules diffusing in horizontally-oriented, cylindrical nanostructures, including surfactant micelles, silica mesopores, block copolymer microdomains, and bolaamphiphile-based organic nanotubes. Our studies clarified nanoscale details on the structural/chemical heterogeneity of the nanostructures, and their impacts on molecular mass transport dynamics.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

PowerSlicing to determine fluorescence lifetimes of water-soluble organic matter derived from soils, plant biomass, and animal manures

Time-resolved fluorescence spectroscopy was used to characterize water-soluble organic matter (WSOM) which plays an important role in soil ecosystem processes. WSOM was extracted from plant biomass, animal manures, and soils from controlled cropping systems studies with known histories of organic amendments. Lifetime constants were derived using the multi-way PowerSlicing method which provides a non-iterative, multi-exponential fitting of decay profiles. The lifetimes obtained by PowerSlicing were not significantly different from those obtained using the traditional discrete components analysis. The three components attributed to WSOM had lifetimes of 0.38± 0.14, 2.11±0.72, and 7.08±1.18 ns which are in agreement with previous lifetimes reported for humic substances. This study provides further support for the new paradigm for the structure of soil organic matter where the organic matter is composed of low-molecular-weight components held together by hydrogen bonding and hydrophobic interactions.

08 HYDROGEN↗

Analytical Energy Dispersive X-Ray Fluorescence Measurements with a Scanty Amounts of Plant and Soil Materials

Elemental evaluations in scanty powdered material have been made using energy dispersive X-ray fluorescence (EDXRF) measurements, for which formulations along with specific procedure for sample target preparation have been developed. Fractional amount evaluation involves an itinerary of steps; (i) collection of elemental characteristic X-ray counts in EDXRF spectra recorded with different weights of material, (ii) search for linearity between X-ray counts and material weights, (iii) calculation of elemental fractions from the linear fit, and (iv) again linear fitting of calculated fractions with sample weights and its extrapolation to zero weight. Thus, elemental fractions at zero weight are free from material self absorption effects for incident and emitted photons. The analytical procedure after its verification with known synthetic samples of macro-nutrients, potassium and calcium, was used for wheat plant/ soil samples obtained from a pot experiment.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Fluorescence Quenching of Dyes by Graphene Oxide

Fluorescence quenching of four dyes [acridine orange (AO), rhodamine B (Rd B), rhodamine 110 (Rd 110), and rhodamine 640 (Rd 640)] by colloidal graphene oxide (GO) in phosphate buffer (pH 6.0) was studied. Dynamic and static quenching were analyzed using the Stern–Volmer equation. Static quenching by graphene oxide was observed for AO, Rd 640, and Rd B whereas mixed dynamic and static quenching was characteristic of Rd 110. The Stern–Volmer constant of dynamic quenching was 10 times less than that of static quenching. The measured association constants of the dyes with GO fell in the order 2540 (AO) > 495 (Rd 640) > 260 (Rd 110) > 144 L/g (Rd B). The value of the π–π-stacking interaction was strongly influenced by the phthalic fragment oriented perpendicular to the xanthene in the rhodamine dyes and the four alkyl groups of Rd B as a result of their torsional vibrations and rotational motions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Fluorescence and Nonlinear Optical Properties of Alizarin Red S in Solvents and Droplet

The enhancement of the nonlinear properties of materials is an interesting topic since it has many applications in optical devices and medicines. The Z-scan technique was used to study the values of the two-photon absorption (β), second-order molecular hyperpolarizability (γ{sub R}), third-order susceptibility (χ{sub R}), and nonlinear refractive index (n{sub 2}) of Alizarin Red S in different media using a continuous-wave diode-pump laser radiation at 532 nm. For Alizarin Red S in a droplet, the β, n{sub 2}, χ{sub R,} and γ{sub R} were estimated at the order of 10{sup −7} cm{sup 2}/W and 10{sup −12} cm/W, 10{sup −3} m{sup 3} W{sup −1} s{sup −1} and 10{sup −24} m{sup 6} W{sup −1} s{sup −1}, respectively. The results indicated that the values of β and n{sub 2} reduced, whereas the values of χ{sub R} and γ{sub R} were enhanced when the solvent was changed from droplet to water, DMF, and dimethyl sulfoxide due to the change in the solvent’s dielectric constant (ε). Moreover, the values of β were enhanced by an increase in the concentration of the surfactant in the aqueous solution. The absorption spectra of Alizarin Red S in the aqueous solution was observed at 428 nm, and a few red shifts in the absorption spectra were observed with a reduction in the dielectric constant of the medium. The same effect was observed in the absorption spectra of Alizarin Red S in the droplet when the bulk dielectric constant reduced. The dielectric constant can affect the fluorescence spectra of Alizarin Red S when the solution is changed from water to dimethyl sulfoxide. The dipole moments of Alizarin Red S in the different media were studied using the quantum perturbation theory.

74 ATOMIC AND MOLECULAR PHYSICS↗

Synchrotron-based X-ray fluorescence imaging and elemental mapping from biological samples

The present study utilized the new hard X-ray microspectroscopy beamline facility, X27A, available at NSLS, BNL, USA, for elemental mapping. This facility provided the primary beam in a small spot of the order of {approx}10 {mu}m, for focussing. With this spatial resolution and high flux throughput, the synchrotron-based X-ray fluorescent intensities for Mn, Fe, Zn, Cr, Ti and Cu were measured using a liquid-nitrogen-cooled 13-element energy-dispersive high-purity germanium detector. The sample is scanned in a 'step-and-repeat' mode for fast elemental mapping measurements and generated elemental maps at 8, 10 and 12 keV, from a small animal shell (snail). The accumulated trace elements, from these biological samples, in small areas have been identified. Analysis of the small areas will be better suited to establish the physiology of metals in specific structures like small animal shell and the distribution of other elements.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Americium characterization by X-ray fluorescence and absorption spectroscopy in plutonium uranium mixed oxide

Plutonium uranium mixed oxide (MOX) fuels are currently used in nuclear reactors. The actinides in these fuels need to be analyzed after irradiation for assessing their behaviour with regard to their environment and the coolant. In this work the study of the atomic structure and next-neighbour environment of Am in the (Pu,U)O₂ lattice in an irradiated (60 MW d kg⁻¹) MOX sample was performed employing micro-X-ray fluorescence (µ-XRF) and micro-X-ray absorption fine structure (µ-XAFS) spectroscopy. The chemical bonds, valences and stoichiometry of Am (~0.66 wt%) are determined from the experimental data gained for the irradiated fuel material examined in its peripheral zone (rim) of the fuel. In the irradiated sample Am builds up as Am³⁺ species within an [AmO₈]¹³⁻ coordination environment (e.g. >90%) and no (<10%) Am(IV) or (V) can be detected in the rim zone. The occurrence of americium dioxide is avoided by the redox buffering activity of the uranium dioxide matrix. - Graphical abstract: Americium LIII XAFS spectra recorded for the irradiated MOX sub-sample in the rim zone for a 300 μm×300 μm beam size area investigated over six scans of 4 h. The records remain constant during multi-scan. The analysis of the XAFS signal shows that Am is found as trivalent in the UO₂ matrix. This analytical work shall open the door of very challenging analysis (speciation of fission product and actinides) in irradiated nuclear fuels. - Highlights: • Americium was characterized by microX-ray absorption spectroscopy in irradiated MOX fuel. • The americium redox state as determined from XAS data of irradiated fuel material was Am(III). • In the sample, the Am³⁺ face an AmO₈¹³⁻coordination environment in the (Pu,U)O₂ matrix. • The americium dioxide is reduced by the uranium dioxide matrix.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Phase transformation and fluorescent enhancement of ErF 3 at high pressure

In this study, pressure-induced phase transformation and fluorescent properties of ErF 3 were investigated here using in-situ synchrotron X-ray diffraction and photoluminescence up to 32.1 GPa at room temperature. Results showed that ErF 3 underwent a reversible pressure-induced phase transition from the β-YF 3 –type to the fluocerite LaF 3 -type at 9.8 GPa. The bulk moduli B 0 for low- and high-pressure phases were determined to be 130 and 208 GPa, respectively. Also, photoluminescencent studies showed that new emission lines belonging to the transition of 2 H 11/2 → 4 I 15/2 , 4 S 3/2 → 4 I 15/2 , and 4 F 9/2 → 4 I 15/2 appeared during phase transition, suggesting pressure-induced electronic band splitting. Remarkably, significant pressure-induced enhancement of photoluminescence was observed, which was attributed to lattice distortion of the material under high pressure.

36 MATERIALS SCIENCE↗

Development of a combined K-edge subtraction and fluorescence subtraction imaging system for small animals

A novel combined imaging system for small animals using dilute concentrations of iodine as a contrast agent was developed for wide and pencil photon beam image acquisitions. This combined imaging system used K-edge subtraction (KES) and fluorescence subtraction imaging (FSI) and was tested at the Hard x-ray Microanalysis beamline at the Canadian Light Source. The initial wide beam KES image acquired with a charge-coupled device camera was used to identify regions of interest for further investigation and determine the location and area of the raster scan for pencil beam imaging. The pencil photon beam scanning mode acquired simultaneously KES and FSI measurements with an ionization chamber measuring the KES data and a multielement germanium detector measuring the FSI data. A description of the system is given as well as preliminary results using an iodine test object.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

X-ray reflectivity and total reflection x-ray fluorescence study of surface oxide evolution in a GaAs/AlAs multilayer system

Modifications of GaAs/air interface under x-ray exposure have been investigated by means of x-ray reflectometry (XRR). For this purpose a GaAs/AlAs multilayer system was continuously monitored for 90 h while acquiring XRR profiles. Three different starting models for the oxide/contaminants layer were tested for the analysis of XRR data and discussed. The main effect of x-ray exposure, revealed by the three different approaches, is an increase in the thickness of the gallium and arsenic oxides until a saturation value (about 3.0 nm) is reached after about 50 h. Total reflection x-ray fluorescence analysis performed on a couple of twin samples, either irradiated and nonirradiated, confirms that the oxidation process is promoted by x-ray exposure and indicates the presence of a richer As oxide phase at the surface of the x-ray irradiated samples.

36 MATERIALS SCIENCE↗

Application of the high-resolution grazing-emission x-ray fluorescence method for impurities control in semiconductor nanotechnology

We report on the application of synchrotron radiation based high-resolution grazing-emission x-ray fluorescence (GEXRF) method to measure low-level impurities on silicon wafers. The presented high-resolution GEXRF technique leads to direct detection limits of about 10{sup 12} atoms/cm{sup 2}. The latter can be presumably further improved down to 10{sup 7} atoms/cm{sup 2} by combining the synchrotron radiation-based GEXRF method with the vapor phase decomposition preconcentration technique. The capability of the high-resolution GEXRF method to perform surface-sensitive elemental mappings with a lateral resolution of several tens of micrometers was probed.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

A diamond anvil cell for x-ray fluorescence measurements of trace elements in fluids at high pressure and high temperature

We present a new diamond anvil cell (DAC), hereafter called the fluoX DAC, dedicated for x-ray fluorescence (XRF) analysis of trace elements in fluids under high pressure and high temperature to 10 GPa and 1273 K at least. This new setup has allowed measurement of Rb, Sr, Y, Zr, with concentrations of 50 ppm to 5.6 GPa and 1273 K. The characteristics of the fluoX DAC consist in an optimized shielding and collection geometry in order to reduce the background level in XRF spectrum. Consequently, minimum detection limits of 0.3 ppm were calculated for the abovementioned elements in this new setup. This new DAC setup coupled to the hard x-rays focusing beamline ID22 (ESRF, France) offers the possibility to analyze in situ at high pressure and high temperature, ppm level concentrations of heavy elements, rare earth elements, and first transition metals, which are of prime importance in geochemical processes. The fluoX DAC is also suitable to x-ray diffraction over the same high pressure-temperature range.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Absolute nitrogen atom density measurements by two-photon laser-induced fluorescence spectroscopy in atmospheric pressure dielectric barrier discharges of pure nitrogen

In this paper, two-photon absorption laser induced fluorescence spectroscopy is used to follow the nitrogen atom density in flowing dielectric barrier discharges fed with pure nitrogen and operating at atmospheric pressure. Two different dielectric barrier discharge regimes are investigated: the Townsend regime, which is homogeneous although operating at atmospheric pressure, and the more common filamentary regime. In both regimes, densities as high as 3x10{sup 14}/cm{sup 3} are detected. However, the N atoms kinetic formation depends on the discharge regime. The saturation level is reached more rapidly with a filamentary discharge. For a given discharge regime, the N atom density depends strongly on the energy dissipated in the plasma between the gas inlet and the measurement position, whether the energy is varied by varying the position of the measurements, the gas flow, or the dissipated power. Experiments performed in the postdischarge show that the N atom decay cannot be simply attributed to three-body recombination of atomic nitrogen with nitrogen molecules, meaning that other mechanisms such as surface recombination or gas impurities play a role.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

High energy x-ray diffraction/x-ray fluorescence spectroscopy for high-throughput analysis of composition spread thin films

High-throughput crystallography is an important tool in materials research, particularly for the rapid assessment of structure-property relationships. We present a technique for simultaneous acquisition of diffraction images and fluorescence spectra on a continuous composition spread thin film using a 60 keV x-ray source. Subsequent noninteractive data processing provides maps of the diffraction profiles, thin film fiber texture, and composition. Even for highly textured films, our diffraction technique provides detection of diffraction from each family of Bragg reflections, which affords direct comparison of the measured profiles with powder patterns of known phases. These techniques are important for high throughput combinatorial studies as they provide structure and composition maps which may be correlated with performance trends within an inorganic library.

36 MATERIALS SCIENCE↗

Low axial drift stage and temperature controlled liquid cell for z-scan fluorescence correlation spectroscopy in an inverted confocal geometry

A recent iteration of fluorescence correlation spectroscopy (FCS), z-scan FCS, has drawn attention for its elegant solution to the problem of quantitative sample positioning when investigating two-dimensional systems while simultaneously providing an excellent method for extracting calibration-free diffusion coefficients. Unfortunately, the measurement of planar systems using (FCS and) z-scan FCS still requires extremely mechanically stable sample positioning, relative to a microscope objective. As axial sample position serves as the inherent length calibration, instabilities in sample position will affect measured diffusion coefficients. Here, we detail the design and function of a highly stable and mechanically simple inverted microscope stage that includes a temperature controlled liquid cell. The stage and sample cell are ideally suited to planar membrane investigations, but generally amenable to any quantitative microscopy that requires low drift and excellent axial and lateral stability. In the present work we evaluate the performance of our custom stage system and compare it with the stock microscope stage and typical sample sealing and holding methods.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗