Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Fiber”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,351 records · Page 75

Fiber optic system for direct detection of CO2 leakage in carbon storage wells

The feasibility study focused on the development of new fiber for distributed chemical sensing (DCS) that will allow direct detection of CO 2 leakages in the environment. This is particularly important for monitoring well integrity for carbon capture and storage (CSS), to provide early warning for an incoming well failure and potential CO 2 leaking through it. We proposed Raman or IR interrogation within gas-filled Holey Fibers (HoFs) interleaved with standard solid core fibers and Fiber Bragg Grating (FBG) sections, so that the location and concentration of the gases would be provided simultaneously by means of reflectometry. The methodology would overcome current roadblocks to using fiber optics for CO 2 (and other gases) detection in wells with direct in-situ measurements of concentration along with other important parameters such as temperature and pressure as the baseline of environment background.

25 ENERGY STORAGE↗

“Hybridizing heat-integrated 3D printed modules with mass manufacturable, low pressure drop fiber sorbents” (Final Report)

The overall objective of this proposal was to research, develop, and evaluate a modular direct air capture (DAC) system that is simple and scalable. This system was based on the adsorption of CO 2 into commercial polyamines supported by porous fiber sorbents, which can be produced at kilometer per hour scales using our pre-pilot spinning line. We have housed these fiber materials in novel 3D printed modular housing systems that provide easy-to-manufacture and localized heat integration and flow control. This hybridization of fiber sorbent technology with modular housing provided several advantages that led to lower air pressure drops, higher sorbent productivity, as well as ease of manufacturing and assembly unrivaled by existing and emerging heat integrated contactor designs. The modular housing was fabricated with the following features, at a minimum: (i) a tapered air intake to reduce pressure drop related to entrance effects, (ii) a structured network of heat transfer channels to enable localized cooling and heating during adsorption and desorption, respectively, and (iii) low pressure drop supports for the fiber sorbents. This hybrid manufacturing approach provides a facile method for taking fiber sorbents from lab scale to pilot scale as it dramatically simplifies the fabrication of heat integrated contactor structures.

42 ENGINEERING↗

Modularization of Ceramic Hollow Fiber Membrane Technology for Air Separation

This proposed project is aimed at studying high performance and economically competitive ceramic membrane technology for air separation and high-purity oxygen production using hollow fiber ceramic membrane stack and module technology. The design of the single permeate membrane is a hollow fiber substrate-supported thin tri-layer structure. Radially well-aligned micro-channels are embedded in the thick substrate and open at the inner surface of the substrate, enabling facile air/gas diffusion. The tri-layer structure of thin dense membrane layer (~ 10 µm) sandwiched by porous surface layer on either side is then built on the substrate using advanced fabrication process. The tri-layer structure design allows different materials to be used in different layers, where the materials of surface layers have high surface exchange coefficients while the material of dense layer has high bulk diffusivity. Such a synergetic combination leads to high permeation performance. The focus of the proposed project will be on membrane stack/module development using the developed single hollow fiber membranes, including: 1) fabrication and characterization of novel single hollow fiber membranes; 2) membrane stack design and assembly using fabricated single membranes; 3) stack modeling and analysis to guide membrane stack designs; 4) permeation performance testing and characterization of membrane stacks. The hollow fiber feature and simple sealing requirement enable very compact design of membrane stacks, which have excellent flexibility for further modularizations at different scales. The operations of such membrane stack and module may employ the exhaust heat from other components of Integrated Gasification Combined Cycle and oxy-combustion systems. Therefore, modularization of such an air separation membrane technology can be incorporated into the DOE’s REMS (radically engineered modular systems)-gasification skid and support the oxidant feed of an oxygen-blown REMS gasifier scaled to different ranges.

01 COAL, LIGNITE, AND PEAT↗

Multi-Parameter Optical Fiber for Distributed Sensing of Humidity, CH4, CO2, and Corrosion

This work describes the use of the optical fiber sensor (OFS) for successful monitoring of humidity, CH4, and CO2 based on the strain produced along the single-mode fiber (SMF) sensor. This is enabled by absorption of H2O/gases onto the commercially available polyacrylate coated jacketed portion of the fiber resulting in a change in strain. Under equilibrium, a differential microstrain was observed along the jacketed portion of the SMF with N2, CH4, and CO2 at different relative humidity (RH) conditions. The strain response of the SMF under various mixed gas composition and different RH conditions were also measured and made calibration curves accordingly. Linear regression and principal component analysis of the strain datasets provided deconvolution of the impact of strain from H2O, N2, CH4, and CO2. Additionally, modified OFS comprised of the Fe coated fiber section was employed to monitor corrosion based on the increase in backscattered intensity amplitude of the light being passed once corrosion of Fe occurs. Also, corrosion of Fe was studied under soil by installing the fiber in soil with protective measures which would prevent the sensor being mechanically disturbed or broken during installation. The corrosion rates were studied by monitoring the rate at which the intensity of backscattered light amplitude attains a steady state value when complete corrosion of Fe with a specific coating thickness occurs.

Mainali, Badri↗

Electrospun Si and Si/C Fiber Anodes for Li-Ion Batteries

Due to structural changes in silicon during lithiation/delithiation, most Li-ion battery anodes containing silicon show rapid gravimetric capacity fade upon charge/discharge cycling. Herein, we report on a new Si powder anode in the form of electrospun fibers with only poly(acrylic acid) (PAA) binder and no electrically conductive carbon. The performance of this anode was contrasted to a fiber mat composed of Si powder, PAA binder, and a small amount of carbon powder. Fiber mat electrodes were evaluated in half-cells with a Li metal counter/reference electrode. Without the addition of conductive carbon, a stable capacity of about 1500 mAh/g (normalized to the total weight of the anode) was obtained at 1C for 50 charge/discharge cycles when the areal loading of silicon was 0.30 mgSi/cm2, whereas a capacity of 800 mAh/g was obtained when the Si loading was increased to ~1.0 mgSi/cm2. On a Si weight basis, these capacities correspond to >3500 mAh/gSi. The capacities were significantly higher than those found with a slurry-cast powdered Si anode with PAA binder. There was no change in fiber anode performance (gravimetric capacity and constant capacity with cycling) when a small amount of electrically conductive carbon was added to the electrospun fiber anodes when the Si loading was ≤1.0 mgSi/cm2.

Mondal, Abhishek N.↗

Predicting Mechanical Properties from Microstructure Images in Fiber-Reinforced Polymers Using Convolutional Neural Networks

Evaluating the mechanical response of fiber-reinforced composites can be extremely time-consuming and expensive. Machine learning (ML) techniques offer a means for faster predictions via models trained on existing input–output pairs and have exhibited success in composite research. This paper explores a fully convolutional neural network modified from StressNet, which was originally used for linear elastic materials, and extended here for a non-linear finite element (FE) simulation to predict the stress field in 2D slices of segmented tomography images of a fiber-reinforced polymer specimen. The network was trained and evaluated on data generated from the FE simulations of the exact microstructure. The testing results show that the trained network accurately captures the characteristics of the stress distribution, especially on fibers, solely from the segmented microstructure images. The trained model can make predictions within seconds in a single forward pass on an ordinary laptop, given the input microstructure, compared to 92.5 h to run the full FE simulation on a high-performance computing cluster. These results show promise in using ML techniques to conduct fast structural analysis for fiber-reinforced composites and suggest a corollary that the trained model can be used to identify the location of potential damage sites in fiber-reinforced polymers.

Sun, Yixuan (ORCID:0000000311093380)↗

Acoustic Sensing Fiber Coupled with Highly Magnetostrictive Ribbon for Small-Scale Magnetic-Field Detection

Fiber-optic sensing has shown promising development for use in detecting magnetic fields for downhole and biomedical applications. Coupling existing fiber-based strain sensors with highly magnetostrictive materials allows for a new method of magnetic characterization capable of distributed and high-sensitivity field measurements. This study investigates the strain response of the highly magnetostrictive alloys Metglas® 2605SC and Vitrovac® 7600 T70 using Fiber Bragg Grating (FBG) acoustic sensors and an applied AC magnetic field. Sentek Instrument’s picoDAS interrogated the distributed FBG sensors set atop a ribbon of magnetostrictive material, and the corresponding strain response transferred to the fiber was analyzed. Using the Vitrovac® ribbon, a minimal detectable field amplitude of 60 nT was achieved. Using Metglas®, an even better sensitivity was demonstrated, where detected field amplitudes as low as 3 nT were measured via the strain response imparted to the FBG sensor. Distributed FBG sensors are readily available commercially, easily integrated into existing interrogation systems, and require no bonding to the magnetostrictive material for field detection. The simple sensor configuration with nanotesla-level sensitivity lends itself as a promising means of magnetic characterization and demonstrates the potential of fiber-optic acoustic sensors for distributed measurements.

Dejneka, Zach (ORCID:0000000179415708)↗

Modeling and Simulation of Compression Molding Process for Sheet Molding Compound (SMC) of Chopped Carbon Fiber Composites

Compression molded SMC composed of chopped carbon fiber and resin polymer which balances the mechanical performance and manufacturing cost presents a promising solution for vehicle lightweight strategy. However, the performance of the SMC molded parts highly depends on the compression molding process and local microstructure, which greatly increases the cost for the part level performance testing and elongates the design cycle. ICME (Integrated Computational Material Engineering) approaches are thus necessary tools to reduce the number of experiments required during part design and speed up the deployment of the SMC materials. As the fundamental stage of the ICME workflow, commercial software packages for SMC compression molding exist yet remain not fully validated especially for chopped fiber systems. In this study, SMC plaques are prepared through compression molding process. The corresponding simulation models are built in Autodesk Moldflow with the same part geometry and processing conditions as in the molding tests. The output variables of the compression molding simulations, including press force history and fiber orientation of the part, are compared with experimental data. Influence of the processing conditions to the fiber orientation of the SMC plaque is also discussed. It is found that generally Autodesk Moldflow can achieve a good simulation of the compression molding process for chopped carbon fiber SMC, yet quantitative discrepancies still remain between predicted variables and experimental results.

36 MATERIALS SCIENCE↗

Detection of fiber cracking by acoustic emission.

A theoretical model is presented that relates acoustic emission to fiber cracking which occurs during a rising load tension test on a fiber reinforced composite. The percentage of broken fibers in an Al3Ni fiber reinforced aluminum was measured as a function of tensile strain by optical inspection of the polished surface of strained specimens. This information was used in conjunction with the proposed model to predict the acoustic emission response of the composite material. These predictions were compared with experimental observations, and a good agreement was obtained between the two sets of results. These results indicate that it is possible to relate acoustic emission quantitatively to the micromechanics of the deformation processes occurring within fiber reinforced composites, thereby demonstrating the applicability of acoustic emission to materials studies and also to nondestructive evaluation of the integrity of composite materials.

Harris, D. O.↗

An exploratory study of the microstructure of mullite fibers

Mullite fibers of three compositions, ranging from SiO2-rich to Al2O3-rich, were investigated by a number of transmission electron microscopy (TEM) techniques. The fibers were examined in the as-received condition and after subjecting them to thermal exposures as high as 142 C. The investigative techniques used included direct TEM of microtomed sections of mounted fibers and TEM of replicas of polished, chemically etched, and cathodically etched fibers. In addition, X-ray diffraction line broadening analyses was used for determining average crystallite size. A preliminary description of the microstructure of mullite fibers is given.

Santoro, G. J.↗

Development of manufacturing process for large-diameter composite monofilaments by pyrolysis of resin-impregnated carbon-fiber bundles

Large diameter, carbon-carbon composite, monofilaments were produced from the pyrolysis of organic precursor resins reinforced with high-strenght carbon fibers. The mechanical properties were measured before and after pyrolysis and the results were correlated with the properties of the constituents. The composite resulting from the combination of Thornel 75 and GW-173 resin precursor produced the highest tensile strength. The importance of matching strain-to-failure of fibers and matrix to obtain all the potential reinforcement of fibers is discussed. Methods are described to reduce, within the carbonaceous matrix, pyrolysis flaws which tend to reduce the composite strength. Preliminary studies are described which demonstrated the feasibility of fiber-matrix copyrolysis to alleviate matrix cracking and provide an improved matrix-fiber interfacial bonding.

Bradshaw, W. G.↗

An evaluation of upgraded boron fibers in epoxy-matrix composites

An initial evaluation of upgraded boron fibers in an epoxy matrix is performed. Data generated on the program show that fiber strength does increase as a consequence of the upgrading treatment. However, the interlaninar shear strength of upgraded fiber composites is lower than that for an untreated fiber composite. In the limited tests performed, the increased fiber strength failed to translate into the composite.

Rhodes, T. C.↗

An Exploratory Study of the Microstructure of Mullite Fibers

The microstructures of mullite composition fibers were examined by transmission electron microscopic techniques and by X-ray diffraction analyses. Both spun and monofilament fiber structures contained little porosity, nor did the degree of porosity change after heating the monofilament to 1205 C for one half hour. Thermal exposure produced crystallite growth and nucleation from the amorphous phase in all three of the spun fibers. After 116 hours at 1426 C, the crystallites of the standard spun fibers became contiguous. In addition, the surface crystallites of these fibers were found to be more than twice as large as the interior crystallites.

Santoro, G.↗

Effects of thermal loading on fiber-reinforced composites with constituents of differing thermal expansivities.

Estimates of the magnitudes of elastic stresses and elastoplastic stresses and strains were made for tungsten fiber-reinforced 80Ni + 20Cr matrix composites. Heating or cooling between 80 and 2000 F was assumed. The calculated elastic stresses exceeded representative or estimated strengths of constituents. For composites with less than 0.65 volume fraction of fiber, plastic flow was considered possible, and elastoplastic solutions indicated that stresses would be reduced but with the concomitant occurrence of sufficiently large strain ranges, particularly in the matrix, to pose a possible thermal fatigue problem. Limited experimental studies on tungsten fiber-copper matrix composites heated and cooled a number of times between 80 and 1600 F in a conventional furnace and then heated from 80 to 1652 F in a hot-stage microscope resulted in matrix microfracture for a 70 volume fraction fiber composite and substantial matrix strain for a 40 volue fraction fiber composite.

Hoffman, C. A.↗

Development of fine diameter mullite fiber

Results are presented of a program to develop and evaluate mullite fiber with a mean diameter under two microns. The two micron fiber is produced by a blowing process at room temperature from a low viscosity (10-25 poise) solution. The blown fiber was evaluated for dimensional stability in thermal cycling to 1371 C, and was equivalent to the 5 micron spun B and W mullite fiber. An additive study was conducted to evaluate substitutes for the boron. Three levels of chromium, lithium fluoride, and magnesium were added to the standard composition in place of boron and the fiber produced was evaluated for chemical and dimensional stability in thermal cycling to 1371 C. The magnesium was the most chemically stable, but the chrome additive imparted the best dimensional stability.

Long, W. G.↗

In situ polymerization of monomers for polyphenylquinoxaline/graphite fiber composites

Methods currently used to prepare fiber reinforced, high temperature resistant polyphenylquinoxaline (PPQ) composites employ extremely viscous, low solids content solutions of high molecular weight PPQ polymers. An improved approach, described in this report, consists of impregnating the fiber with a solution of the appropriate monomers instead of a solution of previously synthesized high molecular weight polymer. Polymerization of the monomers occurs in situ on the fiber during the solvent removal and curing stages. The in situ polymerization approach greatly simplifies the fabrication of PPQ graphite fiber composites. The use of low viscosity monomeric type solutions facilitates fiber wetting, permits a high solids content, and eliminates the need for prior polymer synthesis.

Serafini, T. T.↗

Development and evaluation of ion exchange hollow fibers

An ion exchange hollow fiber impregnated with a vinylpyridine base was developed. The basic exchange resin used to impart the necessary permselectivity to the hollow fiber is a copolymer of vinylpyridine and dibromoethane prepared according to Rembaum. A slight pressure was used to impregnate the exchange monomer mixture into the void structure of the fiber wall, and with maintenance of subambient temperatures, the rate of cross-linking is slow enough to allow the growing polymer to permeate the wall structure before significant increase in polymer molecular weight. These ion exchange fibers are produced from polyacrylonitrile hollow fibers with an appropriate wall structure that enables the impregnating vinylpyridine monomer mixture to form a truly semipermeable anion barrier after curing.

Smith, J. K.↗

Penny-shaped crack in a fiber-reinforced matrix

Using a slender inclusion model developed earlier, the elastostatic interaction problem between a penny-shaped crack and elastic fibers in an elastic matrix is formulated. For a single set and for multiple sets of fibers oriented perpendicularly to the plane of the crack and distributed symmetrically on concentric circles, the problem was reduced to a system of singular integral equations. Techniques for the regularization and for the numerical solution of the system are outlined. For various fiber geometries numerical examples are given, and distribution of the stress intensity factor along the crack border was obtained. Sample results showing the distribution of the fiber stress and a measure of the fiber-matrix interface shear are also included.

Narayanan, T. V.↗